INTENT INtegrated Energy walls Test facility

Similar documents
Solar Flat Plate Thermal Collector

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Evaluation on the Performances of a Ventilated and Non-ventilated Cavity behind a BIPV: Modelling and Experimental Monitoring

Monitoring of Advanced Facades and Environmental Systems

Green Star Design & As Built Submission Template

In general, passive-solar components can be described by the U-value (heat loss coefficient) and

Glazed photovoltaic-thermal component for building envelope structures

Experimental Performance Analyses of a Heat Recovery System for Mechanical Ventilation in Buildings

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Solar Energy for Hospitals

SOME PRELIMINARY RESULTS OF A BUILDING INTEGRATED PHOTOVOLTAIC (BIPV) SYSTEM INSTALLED AT YASAR UNIVERSITY, IZMIR, TURKEY

Ventilated Illuminating Wall (VIW): Natural ventilation and daylight experimental analysis on a 1:1 prototype scale model

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

ADVANCED FAÇADES AND HVAC SYSTEMS: PRELIMINARY RESULTS OF FULL-SCALE MONITORING

Alexandra Troi, EURAC research José L. Hernández and Miguel A. García, CARTIF

CEN/TC 89 - Thermal performance of buildings and building components

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

DEVELOPMENT OF A SOLAR COLLECTOR/SOLAR WATER HEATING SYSTEM TEST CENTER IN IRAN

Design, Fabrication and Experimental Study of a Novel Loopheat-pipe based Solar Thermal Facade Water Heating System

SunSpots. Tests to determine accelerated aging effects on. A Closer Look at Airbag System Testing Techniques. In This Issue.

LABORATORY Energy Exchange Lab Facility for tests on advanced district heating and cooling networks. Foto: Eurac Research/Ivo Corrà

The ZEB Test Cell Laboratory. A facility for characterization of building envelope systems under real outdoor conditions

MEASURING AND TESTING FACILITIES

REAL-TIME CONTROL OF OCCUPANTS THERMAL COMFORT IN BUILDINGS. Galway, Ireland

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Figure 1: Uncovered and covered PVT collectors

Appendix A Brief description of EnergyFlexHouse

Verified net Zero Energy Building with air source heat pumps for SME

Available online at ScienceDirect. Energy Procedia 78 (2015 )

COPYRIGHTED MATERIAL. Contents Overview WHAT'S IN THE SWL PRINTED WHAT'S IN THE SWL ELECTRONIC I NAVIGATION 20 VIII DETAILED DESIGN STRATEGIES E.

Dynamic thermal performance of a PCM window system: characterization using large scale measurements

Introduction and utilizing of natural energy in Net ZEB practice

APEC and ASEAN Energy Efficiency Programs (Windows, Cool Roofs, etc)

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

THE SOLAR AKTIVHAUS A BUILDING EXAMPLE

Solar gains in the glazing systems with sun-shading

Responsive Building Elements Actual Development and Trends Within IEA

Building & Ductwork Airtightness Standards

Building Envelopee Elements and Their Characterization

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

Passive house optimization for Southern Italy based on the New Passivhaus Standard

Window Labelling Program for India

Introduction to basics of energy efficient building design

Enel is about to launch a global Call for startups to select innovative projects in the field of the Renewable Energies.

ANALYSIS AND MITIGATION OF THERMAL EFFECTS ON A LARGE FACADE-MOUNTED PV ARRAY

Assessing the energy performance of modern glass facade systems

Validation of a zonal model to capture the detailed indoor thermal environment of a room heated by a stove

Dynamic simulation of buildings: Problems and solutions Università degli Studi di Trento

Solar Power. Technical Aspects and Environmental Impacts. 6 th March 2011 Sustainable Energy Options (UAU212F) - University of Iceland

SOLAR PHOTOVOLTAIC ENERGY

How to Design Zero Emission Buildings

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

In office buildings, often large windows have been. Total economy of windows and facades in low energy office buildings. Articles

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

The Centre for Sustainable Building (ZUB) * A Case Study

CONTROL STRATEGIES AND ENERGY SAVING POTENTIALS FOR VARIABLE TRANSMITTANCE WINDOWS VERSUS STATIC WINDOWS

Plan. Objectives RUE RUE approach within the BAF Energy management organisation. Rational Use of Energy in the Belgian Armed Forces

Optimise the Specification of a Building Envelope

Active solar heating system with concrete plate heating analysed with dynamical thermal simulations

Chapter 7. Passive Solar Contents

NORTH PROJECT AQABA, JORDAN. Recommended Energy Efficiency and Renewable Energy Measures for the Premium Villa

Investigation of a Solar active glass facade

Sustainable Building Façade and Advanced Fenestration Systems

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.2 Replacement of glazing

The Novel Solar Water Heating by Means of Thermoelectric Modules

ISO INTERNATIONAL STANDARD. Energy performance of buildings Calculation of energy use for space heating and cooling

Energy Saving Benefits of Daylighting Combined with Horizontal Exterior Overhangs in Hot-and-Humid Regions

BASIC EUROPEAN GLAZED COLLECTORS & SOLAR DOMESTIC

EE2E045 A Calculation Method on the Energy Demand of Urban Districts

Education and Industrial Energy Calculation Guide July 2009

SAGEGLASS VARIABLE TINTED GLAZING INPUT SHEET FOR DIAL+ SOFTWARE

Thermal performance of concrete wall panel with advanced coating materials: a sustainable design

Jun Luis Fernando Garcia Gonzalez TRANSSOLAR ACADEMY. Passive Power Hospital

IESVE Compliance for ASHRAE IES Virtual Environment

Analysis of a plus-energy house for improved building and HVAC system design

A NET ZERO ENERGY BUILDING IN ITALY: DESIGN STUDIES TO REACH THE NET ZERO ENERGY TARGET

Contact Details: Phone Fax . Work Description: New Building Extensions Refurbishment Change of Use. Yes No Method:

Thermal Comfort Measurements in a Hybrid Ventilated Office Room

Pearl River Tower. Guangzhou, China. AEI Professional Project Awards January 2014 PHOTO CREDIT: TIM GRIFFITH

International Journal of Mechanical Civil and Control Engineering. Vol. 1, Issue. 3, June 2015 ISSN (Online):

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

Financing Energy Efficiency in Malta and Italy

ECOTOP VF-HF. high efficiency glazed flat-plate solar collectors > MAXIMUM MODULARITY > SIMPLIFIED INSTALLATION

Validation of Heating 7.2 Simulations Using Hot Box Test Data for RASTRA Wall Form System with Expanded Polystyrene Beads

Low energy buildings

Colorado Mountain College: Sustainable Design Standards

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec Existing external wall construction

PASSIVE SOLAR WALL INTEGRATED WITH A LATENT STORAGE LAYER

Building Technology Research in Architectural Practice: Lessons Learned from Implementations of Energy-Efficient Advanced Building Technologies

ScienceDirect. Comparison of steady-state and in-situ testing of high thermal resistance walls incorporating vacuum insulation panels

Solar cooling design: a case study

Nearly Zero Energy Buildings (NZEB) Seán Armstrong, Housing/Building Standards Section, DHPCLG

Poor distribution & glare

Ventilation performance measurement of a decentralized mechanical system with heat recovery using Tracer gas decay method

BIPV a-si through façade

Lecture 3: Utilization of Passive Solar Technology

Transcription:

INTENT INtegrated Energy walls Test facility

Description of the INTENT laboratory INTENT is a laboratory that can evaluate, either in dynamic or static mode, the thermal and energy performance of traditional building components (e.g. walls, windows and doors) and of innovative building envelope systems, such as walls and floors that integrate active solar systems for energy production or radiant circuits. The laboratory consists of: a double chamber with a guard-ring (the Guarded Hot-Box) built in accordance with standards UNI EN ISO 8990 and UNI EN ISO 12567-1; a solar simulator with lamps that emulate solar radiation; an external hydraulic circuit for evaluating the energy performance of hydraulic systems integrated in building components; a detailed monitoring system of sensors and data acquisition instruments that measure significant physical parameters with the aim of determining the characteristics of the test sample. Test sample equipped with measurement sensors When conducting the tests, the specimen is inserted into a frame (Fig.1, no.4) located between the two climate chambers that simulate interior air conditions (a hot box consisting of a guard box (no.1) and a measurement box (no.2)) and exterior air conditions (cold box, no.3) by controlling the temperature, humidity and air velocity. The solar simulator (no.6) reproduces the irradiation conditions on the external surface of the test sample while the hydraulic circuit controls any active hydraulic systems integrated in the sample. The laboratory tests standard elements in accordance with the requirements of standard UNI EN ISO 8990. The aperture in the panel at the bottom of the cold-box and the solar lamps permit the evaluation of the energy performance and thermal properties of active envelope elements with solar systems, in both static and dynamic modes. The hydraulic circuit can be used to calculate the heat absorbed by the active element as well as the heat removed or delivered throughout systems embedded in the construction element. For testing activated building systems (radiant wall/ ceiling/floor systems), connection to the hydraulic circuit and local measurement of heat flows allow the evaluation of the static and dynamic yield performances of the element. Legend 01. Guarded hot-box 02. Measurement hot-box 03. Cold-box 04. Frame 05. Test sample 06. Solar simulator 07. Air conditioning units 08. Opaque panel for regulating air flow 09. Transparent panel for regulating air flow 10. Glazed opening 11. Hydraulic circuit Fig. 1: Cross-section of test bench

Technical specifications for INTENT test bench Guarded hot box Dimensions [m] Temperature [ C] * Humidity [%] ** Air velocity [m/s] *** Height Width Depth Min. Max. Interval Min. Max. Guarded hot box 3.22 3.12 2.10 18.0 40.0 RH <15% --- --- Measurement hot box 2.42 1.92 1.00 18.0 40.0 RH <15% 0.1 0.3 Cold box 3.22 3.12 2.10-20.0 40.0 40% <RH<80% 0.1 10.0 Regulator 3.22 3.12 0.50 --- --- --- --- --- * The temperature is continuously controlled and can vary with a maximum gradient of 0.2 C per minute. The measurement box is equipped only with an heating device. The guarded box and the cold box have air conditioning systems for both heating and cooling. ** The relative humidity in the hot boxes (guarded and measurement) can be maintained under 15% as prescribed in the reference standards, while in the cold box it can be controlled as specified in the table if the temperature is between 20 C and 40 C. *** The air velocity can either be mechanically regulated by varying the dimensions of the channels in which the air is conveyed or automatically by regulating the speed of the installed fans. Solar simulator * Irradiation power [W/m²] Spectral conformity Spatial uniformity [%] Temporal instability [%] Interval ** Class (IEC 904-9) Class (IEC 904-9) Class (IEC 904-9) 350 <Irr<1100 B B <5% B <5% * Data in the table relate to a maximum irradiated surface of 1.5m (width) x 2.0m (height). Increasing the irradiated surface reduces accuracy in comparison to spatial uniformity. ** The power of the solar radiation on the surface of the test sample can be continuously controlled in the specified interval. Hydraulic circuit * Flow rate [l/h] Discharge temperature [ C] Min. Max. Min. Max. 30 600 15 95 * The hydraulic circuit can maintain constant inlet temperature and flow rate as specified and can be used to measure the thermal power exchange between the inlet and outlet flows[w]. In addition pressure losses can also be measured. Measurement sensors Value measured Sensor type Number of sensors available Unit of measure Surface thermocouples (Type T) ~70 C Temperature Air thermocouples (Type T) ~40 C PT100 ~10 C Relative humidity Relative humidity probe 4% 4 % Air velocity Hot-wire anemometer 3 m/s Heat flow Heat flow measuring plate 2 (50x50 cm) + 1 (10x10cm) W/m² Irradiation Pyranometer 1 W/m² Water flow Ultrasound flow meter 1 l/h Pressure difference Differential barometer 1 Pa Electrical power Electrical consumption meter ~5 W

Portable measurement sensors that can be used in the laboratory and on site * Value measured Type of sensor Number of sensors available Unit of measurement Heat transmittance Heat flow measuring plate and 1 W/m 2 surface thermocouple 2 C Heat radiation Thermographic camera 1 C Illumination Lux meter 2 lux Blower door fan Air flow rate 1 m³/s Air velocity Hot-wire anemometer 1 m/s * In addition to the instrumentation integrated into the fixed experimental station, the laboratory also has portable measuring instruments that can be used for measurements such as: heat transmittance of walls (U-value), illumination and calculation of the daylight factor, blower door test, air velocity. What can be measured using INTENT Heat transmittance U [W/(m²K)] of both opaque and transparent elements Instruments used: instrumented guarded hot box Minimum test duration: approx. 48 hours Dynamic properties of passive envelope elements (e.g. time constant [s], time lag [s], etc.) (no reference standards) Instruments used: instrumented guarded hot box + heat flow measuring plates Minimum test duration: approx. 72 hours Dynamic behaviour of active envelope elements (systems with frame activation, radiant floors/ceilings, etc.) Instruments used: instrumented guarded hot box + heat flow measuring plates + solar simulator + hydraulic circuit Minimum test duration: approx. 72 hours Performances of active envelope elements with solar installations (photovoltaic panels and solar thermal collectors) Instruments used: instrumented guarded hot box + heat flow measuring plates + solar simulator + hydraulic circuit Minimum test duration: approx. 72 hours Measurements still under development Solar factor of transparent elements integrating shading devices (g-value) Thermal and energy performances of envelope elements integrating ventilation systems Testing process Activities 1. Define objectives and methods: a. What to measure? E.g. heat transmittance, energy yield, dynamic performances, etc. b. How to measure? Standards to be met, e.g. ISO 12567, definition of new procedures, etc. Responsibility Client and EURAC Standard procedure 2. Design of test sample Client and EURAC 3. Production of test sample Client 4. Installation of test sample in laboratory Client and EURAC 5. Instrumentation of test sample EURAC 6. Conducting of test EURAC 7. Report of test results EURAC On request 8. on request: provision of indications/nomograms for dimensioning and use of the element tested (for design and commissioning) For all phases from 1-7 it is possible to request numerical modelling of the sample tested: finite elements model (FEM) or concentrated parameters model (dynamic simulation software) EURAC EURAC

Open guarded hot box with solar simulator Numerical support for measurement In parallel with the laboratory tests, heat transfer and fluid dynamic analyses throughout numerical models are offered for simulating the behaviour of samples. Two types of model are currently used: the finite element model (FEM) or the concentrated parameters model. The definition of the numerical model and its validation with the measurements in the laboratory offer a very useful tool: the optimisation of the component energy performance: instead of producing several prototypes, numerical models allow the evaluation of prototype changes of any type (e.g. geometry, materials used, etc.) in terms of the parameters to be optimised; the evaluation of the behaviour of the element when integrated into a more complex structure: as an example, the model of the tested element can be inserted into a larger model that simulates the behaviour of an entire building and calculates the overall building thermal and energy performance indexes. Potential users of the test bench INTENT is a laboratory conceived and designed for measuring the energy performances of traditional building components, both opaque (walls, etc.) and transparent (windows, etc.) and, above all, for the development of multifunctional envelope systems that integrate active elements (mass activation, solar thermal panels, photovoltaic modules, etc.). INTENT can therefore supply a measuring and verification service concerning building systems for companies that wish to test the thermal performance of their products in compliance with standards (e.g. wall panel prefabricators - > measuring panel transmittance; window fitters- > measuring frame transmittance, etc.). Moreover, INTENT offers the services needed for developing innovative products (from idea to design, prototyping, measurement and evaluation of energy performances and their optimisation). Research activities are currently concentrated on envelope systems that can contribute to reduce the building energy demand and to optimise the energy production and storage. Envelope passive components (insulation, coverings and shading systems) can be integrated with active components (such as solar heat collectors, photovoltaic panels, etc.). Nowadays, trends in the construction sector include the development of new materials (PCM, VIP, thin and dynamic insulation, etc), new technologies (ventilation and energy production systems for integration in facades) and multifunctional envelope components. The heat and energy evaluation of these components by the INTENT laboratory has a fundamental role in verifying performances, functionality, quality and competitiveness of products that are to be placed on the market. Related activities The INTENT laboratory has been designed as part of a wider network of experimental labs able to meet numerous requirements and demands. As an example, for the evaluation of energy systems for the planning and realisation of Net Zero Energy Buildings, the laboratory interacts with other EURAC laboratories: COSMO (test bench for testing the energy performances of heat pumps and absorption machines) and SoLaRE-PV (laboratory for testing the performances and durability of photovoltaic panels). The laboratory tests are also compared with measurements under operational conditions by means of instrument monitoring. The integrated methodological approach permits the technological development of products from their construction and the evaluation of their performances both numerically and by means of instrumental analysis, in both controlled and actual working conditions. The EURAC Institute for Renewable Energy conducts applied research in the fields of solar energy and building energy management. These activities include research projects at national and international level and direct collaborative ventures with industrial partners, leading in many cases to the development of innovative products and the evaluation of technological and construction solutions. The Institute also offers support in the development of complex energy systems such as Net Zero Energy Buildings. The scientific results are based on the experimental activities carried out in the laboratory and in operational conditions through the monitoring of buildings and systems that use solar energy. Dynamic simulation instruments are also widely employed.

The INTENT laboratory has been financed by The research activities of EURAC Institute for Renewable Energy are kindly supported by EURAC Viale Druso/Drususallee 1 39100 Bolzano/Bozen Italy www.eurac.edu EURAC Institute for Renewable Energy Via Luis-Zuegg, 11 39100 Bolzano/Bozen Italy Tel. +39 0471 055 600 Fax +39 0471 055 699 renewable.energy@eurac.edu Altstadt/ Centro storico Drususallee/Viale Druso Marconistraße/ Via Marconi Schlachthofstraße/ Via Macello Reschenstraße/Via Resia A22 BZ NORD Siemensstraße/ Via Siemens Galileistraße/ Via Galilei A22 BZ SUD Toricelli-Straße/Via Torricelli Albert-Einstein-Straße/ Via Einstein Bruno-Buozzi-Straße/ Via Bruno Buozzi Alessandro-Volta-Straße/ Via Alessandro Volta EURAC Institute for Renewable Energy Luis-Zuegg-Strasse 11/ Via Luis-Zuegg 11