OVER WOOD DECK STANDARD DETAILS Austin - Headquarters/Sales Office 830 Sagebrush Drive Austin, TX 78758 (512) 452-1515 (800) 428-7412 Fax (512) 833-7499 www.ctmrs.com email: info@ctmrs.com Seguin - Plant/Sales Office 720 West IH 10 Seguin, TX 78155 (830) 379-3600 (877) 622-8677 Fax (830) 379-8753
ARCHITECT / ENGINEERING DATA 18" MAX 1 1/2" 1" GENERAL DESCRIPTION Rib height : 1 1/2 Coverage widths: Inquire Integral batten. Standard striations (optional without). Minimum slope: 3:12 Panel attachment: Clip (concealed fastener). Panel Substrate: Galvalume or Galvanized. Gauges: 26, 24, or 22 Coatings: Acrylic Coated Galvalume Paint Grip Silicone Modified Polyester Paint System Kynar 500 Paint System Other substrates and finishes available, please inquire. Use a properly aligned and uniform substructure to avoid panel distortion. Typical substructures include plywood and OSB. All substructure must be properly engineered to meet specified design loads. For illustration purposes, details are shown over plywood decking. Any mechanical attachment device that does not lay flat on the deck will telegraph through the panels. Panels can be used on roofs with transitions or slope changes. All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment. Standard CTMRS fasteners are recommended for attachment to metal and wood for all architectural panels. Use maximum caution when fastening to a wood structure. All panels require sealant at eave or valley conditions. Narrower widths, heavier gauges, striations, and embossing minimize the chance of oil canning. Fastener spacing affects the final appearance of the roof. Oil canning is not a reason for field rejection. SH150 3
RIDGE/HIP TYPICAL DETAILS 4" O.C. OR PANEL SEALANT RIDGE FLASHING "Z" CLOSURE 6" O.C. 2 PER FLOATING RIDGE 4" O.C. OR SEALANT RIDGE FLASH PANEL "Z" CLOSURE FASTENER # 14 (POP RIVET) 4" O.C. 2 PER 2"X2"X16GA. ANGLE SH150 4
VALLEY TYPICAL DETAILS VALLEY WITH OFFSET 12" MAX 4 1 2" MIN. FOR STD. VALLEY 9" MIN. FOR EXT VALLEY PANEL VALLEY TRIM 2 PER 12" O.C. OFFSET FILL END WITH SEALANT 12" O.C. VALLEY WITH INTEGRATED 12" MAX 4 1 2" MIN. FOR STD. VALLEY 9" MIN. FOR EXT VALLEY VALLEY TRIM PANEL 2 PER FILL END WITH SEALANT SH150 5
FIXED RAKE TYPICAL DETAILS FINISHING ON MODULE BOX RAKE 6" O.C. OR PANEL ZEE CLOSURE CONTINUOUS FINISHING OFF MODULE BOX RAKE 6" O.C. OR FIELD TURN PANEL UP 1 1 2" PANEL ZEE CLOSURE CONTINUOUS SH150 6
FLOATING RAKE TYPICAL DETAILS FINISHING ON MODULE BOX RAKE RAKE SUPPORT PARAPET RAKE 6" O.C. OR (DO NOT RESTRICT MOVEMENT OF RAKE SUPPORT) CONTINUOUS FINISHING OFF MODULE PARAPET RAKE 6" O.C. OR BOX RAKE RAKE SUPPORT FIELD TURN PANEL UP 1 1/2" (DO NOT RESTRICT MOVEMENT OF RAKE SUPPORT) CONTINUOUS SH150 7
ALTERNATE RAKE TYPICAL DETAILS FIELD CUT AND FOLD PANEL CONTINUOUS 2 PER SH150 8
EAVE TYPICAL DETAILS PANEL CONTINUOUS SH150 9
GUTTER TYPICAL DETAILS PANEL FASTENER # 14 (POP RIVET) TAPE SEALER GUTTER STRAP FASTENER # 14 (POP RIVET) 2 PER 12" O.C. GUTTER SH150 10
FIXED SIDEWALL TYPICAL DETAILS FINISHING ON MODULE SIDING SIDEWALL PARAPET RAKE FLASHING 6" O.C. OR FASTENER # 4 ( 1 4 "-14 X 7 8 " LAP) OR #7 ( 1 4 "-14 X 7 8 " LONG LIFE) 6" O.C. FINISHING OFF MODULE SIDING SIDEWALL PARAPET RAKE FLASHING 6" O.C. OR FASTENER # 4 ( 1 4 "-14 X 7 8 " LAP) OR #7 ( 1 4 "-14 X 7 8 " LONG LIFE) FIELD TURN PANEL UP 1 1/2" 6" O.C. SH150 11
FLOATING SIDEWALL TYPICAL DETAILS FINISHING ON MODULE SIDING SIDEWALL / PARAPET RAKE FLASHING FLOATING RAKE SUPPORT (DO NOT RESTRICT MOVEMENT OF RAKE SUPPORT) FINISHING OFF MODULE SIDING SIDEWALL / PARAPET RAKE FLASHING FLOATING RAKE SUPPORT (DO NOT RESTRICT MOVEMENT OF RAKE SUPPORT) SH150 12
PEAK TYPICAL DETAILS 4" O.C. OR Z CLOSURE W/ URETHANE SEALANT PEAK FLASHING 6" O.C. CONTINUOUS SH150 13
ENDWALL TYPICAL DETAILS SIDING END WALL / HIGH SIDE EAVE FLASHING 4" O.C. OR FASTENER # 4 ( 1 4 "-14 X 7 8 " LAP) OR #7 ( 1 4 "-14 X 7 8 " LONG LIFE) "Z" CLOSURE W/ SEALANT 6" O.C. COUNTER FLASHING ALTERNATE COUNTER FLASHING CAULK COUNTER FLASHING END WALL / HIGH SIDE EAVE FLASHING FASTENER # 13 (DRIVE PIN) ALTERNATE COUNTER FLASHING END WALL / HIGH SIDE SH150 14
FLOATING ENDWALL TYPICAL DETAILS SIDING END WALL / HIGH SIDE EAVE FLASHING 4" O.C. OR FASTENER # 4 ( 1 4 "-14 X 7 8 " LAP) OR #7 ( 1 4 "-14 X 7 8 " LONG LIFE) "Z" CLOSURE W/ SEALANT 2x2 16 GA ANGLE FASTENER #14 (POP RIVET) 6" O.C. COUNTER FLASHING ALTERNATE COUNTER FLASHING CAULK CAULK COUNTER FLASHING END WALL / HIGH SIDE EAVE FLASHING FASTENER # 13 (DRIVE PIN) ALTERNATE COUNTER FLASHING END WALL / HIGH SIDE EAVE FLASHING SH150 15