Fluorescence Light Microscopy for Cell Biology

Similar documents
MICROSCOPY. "micro" (small) "scopeo" (to watch)

cell and tissue imaging by fluorescence microscopy

Partha Roy

Resolution of Microscopes Visible light is nm Dry lens(0.5na), green(530nm light)=0.65µm=650nm for oil lens (1.4NA) UV light (300nm) = 0.13µm f

Visualizing Cells Molecular Biology of the Cell - Chapter 9

Contents. SCHOOL of FLUORESCENCE. For more information, go to lifetechnologies.com/imagingbasics

Special Techniques 1. Mark Scott FILM Facility

Fluorescence Microscopy. Terms and concepts to know: 10/11/2011. Visible spectrum (of light) and energy

Live cell microscopy

Confocal Microscopes. Evolution of Imaging

Confocal Microscopy & Imaging Technology. Yan Wu

Practical light microscopy: an introduction

A Brief History of Light Microscopy And How It Transformed Biomedical Research

Nodes of regulation in cellular systems

Dino-Lite knowledge & education. Fluorescence Microscopes

FLUORESCENCE. Matyas Molnar and Dirk Pacholsky

Fluorescence Microscopy

SURFACE ENHANCED RAMAN SCATTERING NANOPARTICLES AS AN ALTERNATIVE TO FLUORESCENT PROBES AN EVALUATION

Imaging facilities at WUR

Fluorescence Microscopy

Spectral Separation of Multifluorescence Labels with the LSM 510 META

Automated Digital Microscopy

BIOCHEMIST ALL IN ONE ARTICLE

BIO 315 Lab Exam I. Section #: Name:

Fluorescence Microscopy: A Biological Perspective

Lab 5: Optical trapping and single molecule fluorescence

BIO 315 Lab Exam I. Section #: Name:

F* techniques: FRAP, FLIP, FRET, FLIM,

Con-focal and Multi-photon Microscope Experiment Fundamental. Qian Hu, Lab of Laser Scanning Confocal & Two-Photon Microscopy, ION, CAS

More on fluorescence

Confocal Microscopy Analyzes Cells

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

Super-resolution imaging: early days w/ Video-enhanced DIC, TIRF, PALM, STORM, etc.

ab CytoPainter ER Staining Kit Red Fluorescence

Fast, three-dimensional super-resolution imaging of live cells

Confocal Microscopy of Electronic Devices. James Saczuk. Consumer Optical Electronics EE594 02/22/2000

Methods of Characterizing Neural Networks

ab CytoPainter ER Staining Kit Red Fluorescence

Organelle Atlas APPENDIX TO CHAPTER 4 4A.1

CytoPainter Golgi Staining Kit Green Fluorescence

Contact Details. Dr Alexander Galkin. Office: MBC Room 186. Tel: (028) Frequency and wavelength.

Multiphoton Microscopy: Seeing deeper and clearer

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

Imaging of Cells using fluorescents dyes. By: Josué A. Benjamín Rivera September 27, 2018

Rice/TCU REU on Computational Neuroscience. Fundamentals of Molecular Imaging

λ N -GFP: an RNA reporter system for live-cell imaging

Characterizing Phenotypes of Bacteria by Staining Method

Characterizing Phenotypes of Bacteria by Staining Method

The new LSM 700 from Carl Zeiss

Supplementary Table 1. Components of an FCS setup (1PE and 2PE)

PALM/STORM, BALM, STED

2. Know the parts of a light microscope and general rules for using and focusing a microscope, such as:


FLIM Fluorescence Lifetime IMaging

INTRODUCTION TO FLOW CYTOMETRY

Design for Manufacturability (DFM) in the Life Sciences

1. Carry the microscope in an upright position with both hands and place the base of the microscope 5cm from the edge of the bench

Basic Principles in Flow Cytometry. Flow Cytometry

Visualisation, Sizing and Counting of Fluorescent and Fluorescently-Labelled Nanoparticles

2. Know the parts of a light microscope and general rules for using and focusing a microscope, such as:

ALP (alkaline phosphatase) calibrators were analyzed manually in microtiter plates to find the linearity range by following this protocol:

CELL BIOLOGY - CLUTCH CH TECHNIQUES IN CELL BIOLOGY.

Lab module 6b Receptor-mediated endocytosis

SUPPLEMENTARY INFORMATION

Multiplexed 3D FRET imaging in deep tissue of live embryos Ming Zhao, Xiaoyang Wan, Yu Li, Weibin Zhou and Leilei Peng

Direct visualization, sizing and concentration measurement of fluorescently labeled nanoparticles using NTA

What to look for in a fluorophore. What to do with a fluorophore. Types of fluorochromes

Super-resolution Microscopy

Microscopy from Carl Zeiss

JCB. Supplemental material THE JOURNAL OF CELL BIOLOGY. Hong et al.,

SI Appendix. Supporting Materials (references cited here can be found in the reference list in the main text):

Fluorescence Nanoscopy

Sub-micron scale patterning of fluorescent. silver nanoclusters using low-power laser

AMREP FLOW CYTOMETRY CORE FACILITY. Flow Cytometry Data Analysis Workshop Friday 24 th October

T H E J O U R N A L O F C E L L B I O L O G Y

The most extensively used technique for tissue analysis is light microscopy.

Real-Time Multiplex Kinase Phosphorylation Sensors in Living Cells

Introduction to N-STORM

Final Exam, 176 points PMB 185: Techniques in Light Microscopy

Reading for lecture 11

Widefield Microscopy Bleed-Through

T H E J O U R N A L O F C E L L B I O L O G Y

Cellular imaging using Nano- Materials. A Case-Study based approach Arun Murali, Srivats V

Amnis ImageStream : Technical Reports & Applications

Intracellular localization and trafficking of proteins or How (and why) to find a needle in a haystack

How to use the SP5 confocal microscope

Measurement of point-spread function (PSF) for confocal fluorescence microscopy

JCB. Supplemental material THE JOURNAL OF CELL BIOLOGY. Paul et al.,

FLUORESCENT PEPTIDES. Outstanding Performance and Wide Application Range

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

SUPPLEMENTARY INFORMATION

Two-Photon Microscopy for Deep Tissue Imaging of Living Specimens

DNA Microarray Technology

Think outside the dot.

1/24/2012. Cell. Plasma Membrane

Flow Cytometry For New PhDs

The CQ1 Confocal Quantitative Image Cytometer and its Application to Biological Measurement

Actin cap associated focal adhesions and their distinct role in cellular mechanosensing

Flow Cytometry - The Essentials

Single cell molecular profiling using Quantum Dots. Technical Journal Club Rahel Gerosa

Transcription:

Fluorescence Light Microscopy for Cell Biology Why use light microscopy? Traditional questions that light microscopy has addressed: Structure within a cell Locations of specific molecules within a cell Recent advances now allow these questions to be asked in live cells! 1

Why use light microscopy? Non-traditional biophysical questions that light microscopy can now address: Determine diffusion constants and binding affinities of a molecule at a specific site within a cell. Determine whether two molecules are interacting at a specific time and place within a cell. Much more information than just structure! Outline of topics Microscopes: Conventional fluorescence microscopy Confocal microscopy Deconvolution microscopy Two-photon microscopy Imaging techniques: 3D time-lapse FRAP FRET 2

Web sites for more information and tutorials Olympus microscopy resource center http://www.olympusmicro.com/primer/techniques/fluorescence/fluorhome.html Molecular Expressions Optical Microscopy Primer http://microscopy.fsu.edu/primer/index.html Molecular Probes www.molecularprobes.com Basic operating principles of a light microscope eyepiece objective lens specimen focus condenser 3

Compound microscope design yields magnification and resolution Magnification 5x, 10x, 20x, 25x, 40x, 60x, 100x typically available for microscope objectives 4

Resolution is determined in part by the imaging medium AIR OIL n = refractive index of medium: n=1.0 air; n=1.3 water; n=1.5 oil. (for glass n=1.5) The more light collected, the more complete is the image, and so resolution improves. Resolution quantified by numerical aperture (NA) sinnan 5

What s the resolution limit of light microscopy? ] d Rayleigh s criterion: N nn d = /(2)(NA) d/ n d500/.5 700. 7nmmμ Beware of empty magnification High NA Low NA 6

Inverted Research Microscope new detector original detector old detector Computer controlled Computer Microscopist Detector Microscope (Who needs a microscopist?) 7

Fluorescence Microscopy Predominant mode of light microscopy today Provides molecular specificity Yields high signal to background What is fluorescence? Absorption of a photon with emission of longer wavelength photon 8

Fluorescence is absorption of a higher energy photon with emission of a lower energy photon higher energy (shorter wavelengths) lower energy (longer wavelengths) Typical spectral curves for a fluorescent molecule used in microscopy How do we specifically excite the molecule, and then specifically detect its fluorescence? 9

Specificity provided by filters Filters plus a dichroic mirror Fluorescence Microscopy Emission filter Exciter filter Dichroic mirror Objective Specimen Specimen Filters plus a dichroic mirror 10

Components combined in a small filter cube Fluorescence Inverted Research Microscope excitation filters, dichroic 11

What can we see by fluorescence microscopy? Probes for specific biomolecules Probes for genes Probes for ions Probes for specific biomolecules Fluorescent antibodies (immunofluorescence) Fluorescent biomarkers conjugated fluorescent dye antibody or other binding molecule cellular molecule 12

Examples of immunofluorescence Chromosome axis with topo II Microtubules in an endothelial cell Cell walls in plant cells Histone proteins (green), EGF receptor (red) Examples of fluorescent biomarkers Metaphase chromosomes Nucleic acid (yellow) Actin filaments (tubeworm) Apoptotic cell: Lectin (green), nucleic acid (red) 13

Fluorescent probes for cellular organelles Endoplasmic reticulum Golgi Mitochondria Lysosomes (red), Nucleus (blue) Fluorescent probes for small signaling molecules calcium (pollen tube) phosphatidyl inositol (fibroblasts) camp (fibroblasts) 14

Conclusion: An assortment of fluorescent probes enables detection of a variety of cellular structures and organelles. A more limited assortment of fluorescent probes permits detection of small signaling molecules that regulate cell processes. But cells are 3D!!! How do we get a 3D image of a cell? focus Easy, change the focus. 15

This is called optical sectioning microscopy Acquire a series of focal plane images that span the depth of the cell or object of interest. Example: collecting a 3D image of a tiny fluorescent bead (~0.2 μm) z +4 μm +3 μm +2 μm +1 μm +0 μm -1 μm -2 μm -3 μm -4 μm focal planes 16

3D image stack from the small fluorescent bead focal planes (xy images) The 3D bead image viewed from the side xz section 17

But why didn t we get - xy sections xz section? Because the lens does not collect all of the light emitted by the specimen Therefore the image formed is imperfect. 18

So in 3D the image of a point source always looks like this: out-of-focus light Out-of-focus light creates blur in a 3D image Image Formation Selected focal plane image 19

Image of many real point sources in focus 1 μm out-of-focus A real specimen is composed of many more such point sources 3D microscopy methods to reduce out-of-focus light Confocal microscopy Two-photon microscopy Deconvolution microscopy 20

Conventional fluorescence microscopy excites the whole specimen and collects emitted light from the whole specimen excitation light 3D specimen Confocal microscopy excites the whole specimen but collects emitted light primarily from the focal point 3D specimen 21

A typical research confocal microscope The result is an image with reduced haze, improved contrast and better resolution Confocal Conventional 22

3D images can also be generated Dim specimens are harder to image by confocal because the pinhole rejects a lot of light In practice, the pinhole is often made larger to generate partially confocal images 23

Partially confocal images are a compromise conventional fully confocal (small pinhole) partially confocal (medium pinhole) partially confocal (large pinhole) Conclusion Confocal microscopy can generate high contrast 3D images of specimens. It has been the predominant instrument for high resolution light microscopy in the past 10 years. Dimmer specimens are more challenging. 24

Cells are not only 3D, they are also alive. How do we image changes over time? Computer Detector Shutter Microscope Microscopist Easy, computer-controlled time-lapse imaging But the cells need to be happy too. Sophistication of the chamber depends on the sensitivity of the cells and the duration of the imaging experiment. ph and temperature are key variables. 25

Sometimes the cells are very happy (But our budget is not) Even with perfect incubation conditions, repeated light exposure causes problems heating (?) photobleaching dimmer signal free radicals 26

Photobleaching is always a problem 1 2 3 4 5 6 Bleaching rate depends on the dye Fluor, Cy3 Alexa Dyes have been optimized for bleaching and for the laser lines available on typical confocal microscopes 27

How are living cells labeled with dyes? cell permeable dyes microinjection of dyes endogenous dyes Cell permeant dyes Fura2 Cleaved by non-specific esterases in the cell to become impermeant, and locked in the cell. 28

Calcium concentration can then be measured in space and time Fertilization-induced calcium wave in a starfish oocyte. Confocal images every 5 sec Microinjection microinjection needle patch-clamped neural cell 29

Microinjection is difficult and time-consuming Only a limited number of cells can be injected per experiment (~100) Endogenous probes are now the most convenient and most widely used -barrel chromophore 27 kd Crystal structure of GFP green fluorescent protein 30

Proteins of interest can be tagged with GFP and observed in live cells Gene for Your Protein GFP Transform, transfect cells Translocation of the GFP-tagged glucocorticoid receptor from cytoplasm to nucleus Surprising features often discovered by time-lapse 31

Double or triple labeling of live cells is feasible with GFP variants A spectrum of markers: blue, cyan, green, yellow, red Time-lapse imaging: a case study How is chromatin packaged at the Mbp level in the interphase nucleus? from Molecular Biology of the Cell (1998) Bray et al. And how does this packing change when a region becomes activated? 32

Live-cell imaging done in a specially developed cell line Cells contain ~200 tandemly repeated copies of {MMTV - ras - BPV} and are stably transfected with GFP-GR under tetracycline regulation. The tandem array is visualized as a bright structure above the background of GFP-GR in the nucleus GFP-GR RNA FISH OVERLAY These bright structures are the tandem array because they produce the predicted transcript. 33

How does this structure change over time as transcription is induced? Problems Method: Time-Lapse Imaging Very rapid bleaching Cells become sick after only 10-20 images Cells drift out of focus Changes occur on slow time scale (~4 h) but need ~100 movies Solutions 2D time lapse, 1 image every 15 min Non-confocal images Microscopist manually corrects focus during experiment ~5 data sets collected in parallel The microscope set up Tools: Chambered cover slip, stage heater, conventional fluorescence microscope with xy controlled stage 34

Results Unfolding and refolding suggests fiber packing at different densities Conclusion GFP and its variants have made it possible to easily tag proteins with fluorescent markers, and then observe the behavior of specific cellular structures over time. 35