ChemMasters. Installation Guidelines

Similar documents
ChemMasters. Installation Guidelines ChemDeck, Water Resistant, Traffic Grade Resurfacing System for Horizontal Concrete

KUREZ DR VOX Dissipating Curing Compound

(Specification writer shall choose the most appropriate section that applies to a given scope of work) SECTION Painting and Coating

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

Rust-Oleum Industrial Brands Specification

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX ARDIFLO Pump System Underlayments

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Products

Dist. by: BEST MATERIALS Ph:

List walls, planters, etc.., to which the anti-graffiti coating will be applied. Delete this note from the Contract Specifications.

1.1 SECTION INCLUDES.1 The requirements for the application of water repellents/ anti-graffitiant for exterior surfaces.

SECTION HYDRAULIC CEMENT UNDERLAYMENT

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

E P CONCRETE BLOCK SEALER

Concrete Paving Sealer Clear, tough, gloss finish surface treatment.

DESCRIPTION. DiamondCoat FEATURES AND BENEFITS AREAS OF USE

ARDEX GUIDE SPECIFICATION ARDEX MC RAPID One-Coat Moisture Control System For Concrete to Receive ARDEX Underlayments and Toppings

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

2013 Product Catalogue

Product Guide Specification

FEATURES AND BENEFITS

A guide to protecting masonry with a decorative sheen that extends the life of the surface.

SECTION INTUMESCENT FIREPROOFING

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

Signature Seal 100 Medium-to-High Sheen Sealer VOC Characteristics and Applications

E P CONCRETE BLOCK SEALER

PRODUCT DATA SHEET. Sikafloor -CureHard-24 PRODUCT DESCRIPTION. Transparent surface hardener, dustproofer, sealing and curing compound for concrete

SAMPLE SPECIFICATION

Kolorines Glass Mosaic Tiles Project Specification

Copyright 2002 AIA MASTERSPEC 05/02

FEATURES AND BENEFITS

PFL Glaze Sealer is a highly durable wet-look sealer, ideal for external concrete surfaces including paths and driveways.

SAMPLE SPECIFICATION

ARDEX GUIDE SPECIFICATION ARDEX GPS GENERAL PATCH & SKIMCOAT Trowelable underlayment

SPECIFIER SHALL REMOVE COMMENTS IN BOLD TEXT PRIOR TO SUBMITTING.

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ARDEX GUIDE SPECIFICATION ARDEX K 60 ARDITEX A Rapid Setting Latex Smoothing and Leveling Compound

Union County Vocational - Technical Schools Scotch Plains, New Jersey

RD COATINGS -RD-ELASTOFLEX ELASTOMERIC ACRYLIC WALL COATING SPECIFICATION

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

Surface Guard. Product Data Sheet SPECIFICATION DATA CURE TIMES: (73ºF, 50% RH)

MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

DESCRIPTION FEATURES AND BENEFITS AREAS OF USE. DiamondCoat Polyurethane Concrete Floor Finish is suitable for use in the following areas:

(1:4) Heavy Duty, (1:9) ph Balancing (1:20) All Purpose Cleaner. (Power Cleaner: Water) Quart, 1 Gallon, 5 Gallon Pail, 55 Gallon Drum

Application Guide. PaveCoat

Technical Data Sheet PaveCoat Product Description

Specifier Notes: Edit the following list as required by the project. List other sections with work directly related to the floor coating.

Industrial Sealers & Coatings

Rust-Oleum Industrial Brands Specification

RESURFACES PROPERLY PREPARED WEATHERED WOOD AND CONCRETE

For detailed product information, visit our DeckOver, Textured DeckOver or Extra Textured Deckover product pages.

ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

Nutech Concrete Range

SECTION EPOXY TERRAZZO

STONE ESSENCE SEMI-TRANSPARENT STAIN FOR CONCRETE

ARDEX GUIDE SPECIFICATION ARDEX K 22 F High Flow, Fiber Reinforced, Self-Leveling Underlayment

Construction. Sodium silicate based surface hardener, dustproofer, sealing and curing compound for concrete. Product Description.

SECTION CLEAR PENETRATING SEALERS SPECIFICATION

SECTION HYDRAULIC CEMENT UNDERLAYMENT

SECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES

Specification and Installation

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

Asphalt Maintenance PRODUCTS INFORMATION AND INSTALLATION GUIDE

Pacific Polymers Elasto-Deck 5000MR Guide Specification

KOSTER AMERICAN CORPORATION

FEATURES AND BENEFITS

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Acrylitex Tilt UP Primer Guide Specification Revised August 1, 2008

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SECTION Silane Water Repellents. Vexcon

Master Specifications for Microcotta November 2017

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

TILE TILE

A. This Section includes traffic coatings for the following applications:

SECTION SILOXANE WATER REPELLENTS

BACKSTOP TM NT - Texture A high performance, water-resistive membrane and air barrier

EPOXY FLOORING SYSTEMS

Ger-Eck, LLC SCRIBIL Dry Erase Clear Coat Section July 12, 2013 SECTION SCRIBIL Dry Erase Clear Coat

Part 1 - GENERAL 1.01 DESCRIPTION. Section

Color Stain 5100 System APPLICATION INSTRUCTIONS

ARDEX GUIDE SPECIFICATION ARDEX PANDOMO Wall ARDEX PANDOMO W1 Decorative Wall Finishing Compound

ZONE 7 WATER AGENCY CWS 5 TURNOUT REPLACEMENT PROJECT # ADDENDUM NO. 3 April 02, 2019

ARCHITECTURAL SPECIFICATION

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

Construction. Sikadur 35, Hi-Mod LV. Application Instructions. Sika Corporation

TECHNICAL DATA SHEET HYDROPOX #4 QD 1:1 EPOXY WATERWHITE CLEAR

System Specification CEM-DYE 25 SYSTEM Division 9 Finishes Section Staining and Transparent Finish

A. This specification describes the sealing of vertical joints/cracks with a one-component, gungrade, elastomeric sealants. B.

DOWSIL ALLGUARD Silicone Elastomeric Coating

Epoxol Floor. Two component solvent-free epoxy system for creation of self-levelling floors. Fields of Application. Properties/ Advantages

Product Guide Specification

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

Transcription:

ChemMasters Installation Guidelines Traz 25 is a state of the art, film forming concrete and masonry waterproofing sealer formulated with methyl methacrylate polymers. 1.0 General 1.1 Scope This specification covers the performance characteristics and application procedures for providing a film forming concrete and masonry waterproofing sealer formulated with methyl methacrylate polymers. Traz 25 resists contamination from hydrocarbon based substances and other chemicals. It repels water, is non-yellowing and forms an extremely durable film. 1.2 Material Description The material shall be a film forming concrete and masonry waterproofing sealer formulated with methyl methacrylate polymers. It should provide excellent chemical resistance, high level of resistance to aliphatic solvents, acids, alkali, gasoline, oils and grease, excellent penetration, adhesion and durability, excellent water and liquid repellency reducing staining and moisture absorption, and superior resistance to ultraviolet light, freeze/thaw. 1.3 Typical Applications A. Interior or exterior, horizontal and vertical concrete and masonry, including exposed aggregate, terrazzo and manmade or natural stone B. Precast, poured and formed or tilt-up walls C. Residential, commercial or industrial applications D. Service stations, vehicle repair facilities E. Parking structures, plazas, driveways, patios and sidewalks F. Schools, shopping centers and malls, hospitals, sports arenas and stadiums G. Factories, refineries and warehouses 1.4 Limitations A. Traz 25 is not to be used as a curing compound or as a bond breaker for tilt up construction. B. Traz 25 is not recommended for primary or secondary containment areas or for use under resinous coatings. Consult ChemMasters Technical Service staff for alternative materials. C. Do not use on surfaces scheduled to receive concrete overlays, toppings or thin set mortars. D. Do not apply in the presence of foodstuffs. E. During times of heavy precipitation or excess moisture in the substrate,

Traz 25 may blush or have a milky appearance temporarily. F. Quality curing or sealing compounds and floor treatments may darken or highlight the subtle color variations naturally present in concrete. When the difference in shading caused by absorptive deviation or finishing techniques is objectionable, consult ChemMasters technical staff prior to concrete placement for recommendations. 1.5 Quality Assurance The repair contractor shall have experience and proficiency specific to the repair type and shall be approved by the engineer and the material supplier. The material supplier shall provide job service as required to assure proper handling and installation of materials. The field representative shall instruct as needed to assure that handling, mixing, placing and finishing of materials are in accordance with specifications. 1.6 Delivery, Storage and Handling The product shall be delivered in the original, unopened containers. It shall be labeled with the manufacturer s name, product name and lot number. Materials should be stored at the job site under dry conditions and at a temperature of 40 F., (4 C.) to 90 F. (32 C.). 1.7 Environmental Requirements All materials used for the repair work shall be VOC compliant. The manufacturer shall supply the appropriate material safety data sheets upon request. 1.8 Site Conditions Coverage is dependent upon surface texture and porosity. 2.0 Materials 2.1 Approved Materials and Manufacturers 2.1.1 Product Standard Traz 25, as manufactured by ChemMasters, 300 Edwards Street, Madison, Ohio, 44057-3112, 1-800-486-7866, is considered to conform to the requirements of this specification and shall be the sealer used. Traz 25 is a film forming concrete and masonry waterproofing sealer formulated with methyl methacrylate polymers. Traz 25 resists contamination from hydrocarbon based substances and other chemicals. It repels water, is non-yellowing and forms an extremely durable film. 2.1.2 Substitutions

No submittals for substitutions will be accepted after the bid date. All submittals must be made in writing to the engineer with supporting technical data sheets and test data showing complete equivalent performance. 2.2 Packaging/Coverage/Estimating 2.2.1 Packaging Traz 25 is available in 1 U.S.gallon/3.8 liter cans packed 4 per case, 5 U.S.gallon/18.7 liter pails shipped 36 per pallet shrink wrapped and 55 U.S.gallon/208 liter drums. 2.2.2 Coverage/Estimating: Ft. 2 /gal M 2 /L A. Rough, porous textures: 1. First Coat 200-250 5-6 2. Second coat 300-350 7-8 B. Smooth, dense surface: 1. First coat 250-300 6-7 2. Second coat 350-400 8-9 2.2.3 Storage: Store tightly closed containers in dry area away from direct sunlight and sources of heat. Shelf life of properly stored material is one year from date of manufacture. 2.3 Engineering Properties The following engineering properties shall be typical of material performance when tested under laboratory conditions at 72 F (22.2 C). 2.3.1 Plastic Properties 2.3.1.1 V.O.C. Content: 688 gm/l 2.3.1.2 Solids: 25% 2.3.1.3 Dry time: A. @ 70 F./21 C.: 2 hours B. Recoat time: 1 hour C. Foot traffic: 4 hours D. Heavy traffic: 12 hours 2.3.1.4 Dry film thickness: Mil Ft. 2 /gal M 2 /L A. 2 200 5 B. 1.33 300 7

C. 1 400 9 2.4 Accessory Materials as manufactured by ChemMasters, 300 Edwards Street, Madison, Ohio, 44057-3112, 1-800-486-7866, is considered to conform to the requirements of this specification. 3.0 Execution 3.1 References A. Complies with National Volatile Organic Compound Emission Standards for Architectural Coatings, Federal EPA Regulation 40 CFR Part 59 B. Refer to ChemMasters MSDS and Technical Data Sheets 3.2 Surface Preparation A. Surface must be clean and free from dirt, dust, laitance, oil, grease, paints, curing or sealing compounds, tilt up bond breakers or other contaminants which would prevent proper adhesion. B. If one coat of Spray-Cure & Seal 25 has been applied as a curing compound on new concrete, it does not have to be removed prior to applying Traz 25 but surface must be clean. Curing or curing and sealing compounds other than SprayCure & Seal 25 or multiple coats of Spray-Cure & Seal 25 must be mechanically or chemically removed. C. ChemMasters 1201 Citrus Cleaner or an industrial strength detergent is recommended for final washing. Rinse thoroughly and allow substrate to dry completely. D. Mask or tape any unfilled joints or install joint sealant prior to applying Traz 25. 3.3 Mixing: A. Traz 25 is packaged ready to use and only requires stirring or agitation prior to use. Do not dilute with water or solvents. 3.4 Application: A. Use a short nap roller, lambswool applicator or a solvent resistant, airless sprayer equipped with a fan tip, preferred method. Hold spray tip 6-8 in/ 15-20 cm from surface and apply a continuous film leaving no pinholes or gaps. B. Do not allow material to puddle. C. For higher gloss on porous or open textures or for greater chemical resistance, additional coats may be applied at recommended coverage rate. D. Apply subsequent coats when surface is tack free, normally 1 hour at 70 F./21 C. with 50%relative humidity. E. RECOATING: To recoat Traz 25 treated surfaces after a period of years, clean and degrease as noted above. F. Remove any loose or disbonded material then proceed with installation. There is no need to mechanically or chemically remove initial application.

3.5 Clean-up Clean tools and equipment with Polyseal Solvent, xylene or toluene.