WUIC Proponent: Jason Thompson, National Concrete Masonry Association representing Masonry Alliance for Codes and Standards

Similar documents
IWUIC 2016 GROUP B PUBLIC COMMENT AGENDA

SECTION R327.3 STANDARDS OF QUALITY

CITY SECTION 701A 702A. of this chapter. Protection

Changes to California s Building Code for Construction in Wildfire Prone Areas: Impact on Wood and Wood-based Materials

IWUIC 2018 GROUP A PROPOSED CHANGES TO THE I-CODES COLUMBUS COMMITTEE ACTION HEARINGS. April 15 23, 2018 Columbus Convention Center Columbus, Ohio

WILDLAND URBAN INTERFACE (WUI) PRODUCTS

Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)

INTERNATIONAL WILDLAND-URBAN INTERFACE CODE

MEGA FIRES: The Case for Mitigation

Published by the Authorities Having Jurisdiction listed below. Participating Agencies

IWUIC 2016 GROUP B COMMITTEE ACTION HEARINGS APRIL 17, 2016 APRIL 27, 2016 KENTUCKY INTERNATIONAL CONVENTION CENTER LOUISVILLE, KY

CREATING A FIRE ADAPTED HOME

FOR HOME REPAIR AND CONSTRUCTION

IRC - ROOFING - ROOFING TAC

EMRGENCY EXPRESS TERMS BY THE CALIFORNIA DEPARTMENT OF FORESTRY (CDF) & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL (SFM)

GUIDANCE DOCUMENT IGNITION RESISTANT EAVE CONSTRUCTION

Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

Public Input No. 1-NFPA [ Chapter 2 ]

GUIDANCE DOCUMENT IGNITION RESISTANT EAVE CONSTRUCTION

Plug any roof openings that are not functioning as vents.

Fire Retardants and Truss Design. Overview

International Code Council. ICC XX Public Input Agenda based on input received on Initial Draft

A Review of Thermal and Ignition Barrier Requirements for Spray Foam Insulation

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Agenda. 1. Call to Order - Chair Rick Swan. 2. Introduction of Members and Guests. 3. Chair s Brief Remarks and Purpose of Meeting

INTERNATIONAL EXISTING BUILDING CODE

Let s begin, your first session, module 1, which will cover chapter 2, definitions and a portion of chapter 3, building planning.

Pg. xiv, xv Definitions. Pg. 2 A brief history pg. 12 Codes definition. Pg. 13 The principal purpose of code. Pg. 16 IBC. PG. 27 PG.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

Essentials of Fire Fighting

International Code Council ICC XX Public Input Agenda based on input received on Initial Draft

Recommendations on Proposed International Code Changes


Engineering Analysis of NFPA 285 Tested Assemblies

Excerpts from the Uniform Building Code. (UBC) For The US

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

NEWS LETTER MARCH 27, 2009

Interior FRT Wood. References of Previous Model Building Codes

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SOUTH AFRICAN NATIONAL STANDARD

EXHIBIT A HOMEOWNER NAME: ADDRESS: LOT NO: DATE: PROPOSED START DATE: ANTICIPATED COMPLETION DATE: NAME OF CONTRACTOR: CONTRACTOR S LICENSE NUMBER:

Covered Products: IPE Hardwood Decking, ¾ x 5.3. Report# WFCi Project# Conducted for:

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Choosing Between Fire Retardant and Standard Core Metal Composite Material (MCM)

SECTION : FIRE WALL AND FIRE SUPPRESSION REGULATIONS FOR R1-Z, R-2, R-3 ZONING AND PDD CATEGORIES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

2018 IBC Chapter 6 Types of Construction

KEEPING UP WITH I-CODES

FIRE AND SMOKE PROTECTION FEATURES

Originally Issued: 11/06/2017 Valid Through: 11/30/2018

2015 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

Chapter 2: Foundation

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ICC-ES Evaluation Report. ESR-3102 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

Report to: Plumberex Specialty Products, Inc. Pipe Insulation and Fire Safety

BASIC VENTILATION REQUIREMENTS

Home design and retrofitting. techniques for wildfire defense

July 23, 2010 PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION

FS , 712, 713, 714

Originally Issued: 2/12/2016 Revised: 07/28/2017 Valid Through: 2/28/2018

2006 INTERNATIONAL RESIDENTIAL CODE

MEETING FIRE CODE WITH ORIENTED STRAND BOARD

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

ICC xx Standard for Spray-applied Polyurethane Foam Plastic Insulation

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

Proponent: Charles B. Clark, Jr., Brick Industry Association, representing Masonry Alliance for Codes and Standards

Originally Issued: 03/31/2017 Revised: 03/15/2018 Valid Through: 03/31/2018

Deer Ridge Consulting, Inc.

LEGACY REPORT Reissued October 1, Legacy report on the BOCA National Building Code/1999

INTERMODAL SHIPPING CONTAINER. A six-sided steel framed unit designed as a general cargo container used for the transport of goods and materials.

CHAPTER 6 TYPES OF CONSTRUCTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Copyright Materials. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

VERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC. EVALUATION SUBJECT:

Exception: All layers of single and multilayer reflective plastic core foil insulation shall comply with Section 2604.

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

White Paper. White Paper. Thermal and Ignition Barriers for Spray Foam Insulation. Prescriptive Thermal Barriers

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

O HAGIN ATTIC VENTILATION PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE MOST RECENT BUILDING CODES FOR ATTIC VENTILATION

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

A. Source Limitations: Obtain each type of building insulation through one source.

Transcription:

WUIC1 13 501.3 Proponent: Jason Thompson, National Concrete Masonry Association representing Masonry Alliance for Codes and Standards 501.3 Fire-resistance-rated construction. Where this code requires 1-hour fire-resistance-rated construction, the fire-resistance rating of building elements, components or assemblies shall be determined in accordance with the test procedures set forth in E 119 or UL 263. Exceptions: 1. The fire-resistance rating of building elements, components or assemblies based on the prescriptive designs prescribed in Section 721 of the International Building Code. 2. The fire-resistance rating of building elements, components or assemblies based on the calculation procedures in accordance with Section 722 of the International Building Code. Reason: Section 501.3 of the IWUIC requires building elements, components or assemblies that have to meet the 1-hour fireresistance-rated construction be tested in accordance with E 119 or UL 263. However, there are numerous existing building elements, components or assemblies already considered acceptable to meet fire resistance ratings located in the prescriptive tables in Section 721 of the IBC. In addition, Section 722 of the IBC contains calculation procedures that are also considered acceptable to establish the fire resistance for building elements, components or assemblies based on well-founded engineering principles. This proposed code change makes it clear that the prescriptive tables and the calculation procedures in Chapter 7 of the IBC are also permissible to establish the fire resistance requirements of the IWUIC. Cost Impact: This proposal can reduce the cost of construction by permitting fire-resistance-rated assemblies already recognized in the International Building Code to be used to comply with the provisions of the IWUIC WUIC1-13 501.3-WUIC-THOMPSON WUIC1

WUIC2 13 503.2, Chapter 7 Proponent: Joseph Holland (jholland@frtw.com) and Dave Bueche (dbueche@frtw.com), representing Hoover Treated Wood Products, Inc. dbueche@frtw.com 503.2 Ignition-resistant building material. Ignition-resistant building materials shall comply with any one of the following: 1. Material shall be tested on all sides with the Eextended E 84 (UL 723) testing or E2768, except panel products shall be permitted to test only the front and back faces. Panel products shall be tested with a ripped or cut longitudinal gap of 1/8 inch. Materials that, when tested in accordance with the test procedures set forth in E 84 or UL 723, for a test period of 30 minutes, or E2768, comply with the following: 1.1 through 1.4 (No change to current text) 2 through 4 (No change to current text) Add new standard to Chapter 7 as follows: E2768-11 Standard Test Method for Extended Duration Surface Burning Characteristics of Building Materials (30 Minute Tunnel Test) Reason: The code is not specific as to the testing of materials with a surface treatment. There are painted and laminated products in the marketplace that are painted or laminated on only one side and are only tested on that side. This is inappropriate for many of the applications where ignition-resistant material is permitted; e.g., decks, lapped siding, exposed facia and other installations with a gap between the material. The recommendations of the approved agencies for panel products require a 1/8 inch gap between sheets. Because panel products with a surface treatment will be cut in the field and are mandated a 1/8 inch gap it is important that non factory edges be tested to evaluate the effect of their performance in a fire. developed a standard for testing materials for 30 minutes in the E84 or UL723 tunnel. Use of the standard is appropriate for ignition-resistant material used in the Wildland/Urban Interface. The standard uses E84 as the basis with the extended time period of 30 minutes Cost Impact: As all products should be testing in this manner the will be no cost impact. Analysis: A review of the standard proposed for inclusion in the code, E2768-11, with regard to the ICC criteria for referenced standards (Section 3.6 of CP#28) will be posted on the ICC website on or before April 1, 2013. WUIC2-13 503.2-WUIC-BUECHE-HOLLAND WUIC2

WUIC3 13 503.2, Chapter 7 Proponent: John Woestman, Kellen Company, representing Composite Lumber Manufacturers Association (CLMA) (jwoestman@kellencompany.com) 503.2 Ignition-resistant building material. Ignition-resistant building materials shall comply with any one of the following: 1. Extended E 84 testing. Materials that, when tested in accordance with the test procedures set forth in E 84 or UL 723, for a test period of 30 minutes, comply with the following: 1.1. Flame spread. Material shall exhibit a flame spread index not exceeding 25 and shall show no evidence of progressive combustion following the extended 30-minute test. 1.2. Flame front. Material shall exhibit a flame front that does not progress more than 101/2 feet (3200 mm) beyond the centerline of the burner at any time during the extended 30- minute test. 1.3. Weathering. Ignition-resistant building materials shall maintain their performance in accordance with this section under conditions of use. Materials shall meet the performance requirements for weathering (including exposure to temperature, moisture and ultraviolet radiation) contained in the following standards, as applicable to the materials and the conditions of use: 1.3.1. Method A Test Method for Accelerated Weathering of Fire-Retardant- Treated Wood for Fire Testing in D 2898, for fire-retardant treated wood, woodplastic composite and plastic lumber materials. 1.3.2. D 7032 for wood-plastic composite materials. 1.3.3. D 6662 for plastic lumber materials. 1.4. Identification. All materials shall bear identification showing the fire test results. 21. Noncombustible material. Material that complies with the requirements for noncombustible materials in Section 202. 32. Fire-retardant-treated wood. Fire-retardant-treated wood identified for exterior use and meeting the requirements of Section 2303.2 of the International Building Code. 43. Fire-retardant-treated wood roof coverings. Roof assemblies containing fire-retardant-treated wood shingles and shakes which comply with the requirements of Section 1505.6 of the International Building Code and classified as Class A roof assemblies as required in Section 1505.2 of the International Building Code. 4. Exterior deck materials. Exterior deck materials complying with D7032 and the requirements of 4.1, or 4.2, or 4.3. 4.1 Exterior deck materials complying with all of the following: 4.1.1 Tested in accordance with E2632 and meeting the following acceptance criteria: peak heat release rate not greater than 25 kw/ft 2 ; and absence of sustained flaming or glowing combustion of any kind at the conclusion of the 40 minute observation period; and absence of structural failure of any deck board; and absence of falling particles that are still burning when reaching the burner or floor. 4.1.2 Tested in accordance with E2726 / E2726M using the Class A brand and meeting the acceptance criteria of X1.6.1 or X1.6.2 of E2726 / E2726M. 4.1.3 Tested in accordance with E84 and meeting the Class A flame spread index with the test extended by 20 minutes. 4.2. Exterior deck materials complying with both of the following: 4.2.1 Tested in accordance with E2632 with a peak heat release rate not greater than 25 kw/ft 2. 4.2.2 Tested in accordance with E84 and meeting the Class B flame spread index. WUIC3

4.3. Exterior deck materials installed where the exterior wall covering to which the deck is attached and within 10 feet of the deck is of noncombustible or ignition resistant material and the exterior deck materials complying with both of the following: 4.3.1 Tested in accordance with E2632 with a peak heat release rate not greater than 25 kw/ft 2. 4.3.2 Tested in accordance with E84 and meeting the Class C flame spread index. Add new standards to Chapter 7 as follows: E2632-13 Standard Test Method for Evaluating the Under-Deck Fire Test Response of Deck Materials E2726 / E2726M 12a Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands Reason: This proposal introduces, in new Item 4 of Section 503.2, compliance alternatives for decking materials that are consistent with current California Building Code requirements for wildfire exposure (i.e. wildland urban interface areas), and deletes the existing text of Item 1, which would be redundant with the new text. This proposal revises the IWUIC performance requirements for decking materials to incorporate two standards specifically developed for evaluating the fire performance characteristics of exterior decking materials. These two standards have been developed from current test requirements in the California building code. work product WK12052, which will become E2632-13, is currently at the society review status of approval. E2632 is commonly described as the under-deck fire test for exterior decks. E2726 / E2726M received final approval last year, and is commonly described as the burning brand test for exterior deck walking surfaces. E2632 was developed from California s 2010 Building Code fire test 12-7A-4 Part A, and E2726 was developed from 12-7A-4 Part B. The criteria of 4.1 is intended to be equivalent to the compliance path of the 2010 California Building code for wildfire exposure in 709A.3, Item 1. This criteria of 4.1 is similar to, but more stringent than, the criteria for testing of alternative decking materials of the San Diego County Consolidated Fire Code in Section 26.3.6.2.1, which is for the Wildland / Urban Interface Area. (Note: Criteria 4.1 would be consistent with San Diego County requirements if 4.1.2 is revised to a Class B brand, and 4.1.3 is deleted.) The criteria of 4.2 is consistent with the 2010 California Building Code for wildfire exposure in the Exception to 709A.3. The criteria of 4.3 is consistent with the 2010 California Building Code for wildfire exposure in 709A.3, Item 4. Cost Impact: None Analysis: A review of the standards proposed for inclusion in the code, E2632-13 and E2726/E2726M-12a,with regard to the ICC criteria for referenced standards (Section 3.6 of CP#28), will be posted on the ICC website on or before April 1, 2013. WUIC3-13 503.2-WUIC-WOESTMAN WUIC4

WUIC4 13 504.2, Chapter 7 Proponent: Marcelo M. Hirschler, GBH International (gbhint@aol.com) 504.2 Roof covering. Roofs shall have a roof assembly that complies with a Class A rating when tested in accordance with E 108 or UL 790 roof assembly. For roof coverings where the profile allows a space between the roof covering and roof decking, the space at the eave ends shall be firestopped to preclude entry of flames or embers, or have one layer of 72-pound (32.4 kg) mineral-surfaced, nonperforated cap sheet complying with D3909 installed over the combustible decking. Add new standard to Chapter 7 as follows: E108-11 Standard Test Methods for Fire Tests of Roof Coverings UL UL 790-2004 Standard Test Methods for Fire Tests of Roof Coverings with revisions through October 2008 Reason: This is basically simple clarification, to clarify the test method for the Class A rating. It adds the same and UL standards contained in the IBC for the application. Cost Impact: None Analysis: The standards proposed for inclusion in the code, E108-07a and UL 790-2004, are currently referenced in the IBC. Updates in year editions will be accomplished by an administrative standards update code change to be heard by the ADM Code Development Committee. WUIC4-13 504.2-WUIC-HIRSCHLER WUIC5

WUIC5 13 504.10 Proponent: John D. Nicholas, Perceptive Solutions LLC (john@perceptivesolutionsllc.com) 504.10 Vents. Attic ventilation openings, foundation or underfloor vents, or other ventilation openings in vertical exterior walls and vents through roofs shall not exceed 144 square inches (0.0929 m 2 ) each. Such vents shall be covered with noncombustible corrosion-resistant mesh with openings not to exceed 1/4 inch (6.4 mm), or shall be designed protected with materials or devices that prevent the passage of flame, hot gases, and embers sufficient to ignite cotton waste when tested using the Cotton Pad Test of E119 and approved to prevent flame, hot gases or and ember penetration into the structure. Reason: This proposed code change introduces similar language used by the International Building Code, the Residential Code, and the International Mechanical Code that states protected with materials that prevent the passage of flame and hot gases sufficient to ignite cotton waste This change also provides clarity to the means to be used to determine whether a material or device meets the requirements of to prevent flame, hot gases, and ember penetration into the structure. Section 7.5 of E119 provides a specific means to employ a cotton pad test. This proposed language addresses construction that employs a material or device to protect a vent or ventilation opening, which can be tested as a vertical or horizontal test assembly that is an interior or exterior part of the structure. As with any fire scenario, the fire exposure subjected to vented construction can vary. However, the means to determine compliance with the intent to provide protection to the structure should be a constant. This proposed language provides a means to address variables typically seen in construction. Many times vents are located in storage rooms and other areas where combustibles are stacked. Exterior vents are often in contact with landscaping (vegetation or forestation or both). In some cases, these combustibles are just inches from the vent. When these combustibles are subject to flash over conditions a fire may instantaneously occur with immediate flame impingement upon the vent or ventilation opening. Other times the Wildland fire generates a significant amount of hot gases and embers. Both of which can cause a fire within the structure if not prevented from entering it. The use of a cotton pad test provides a means to determine whether the material or device is meeting the prevention requirements. Cost Impact: This change will not affect the cost of construction. Analysis: E119 is currently referenced in the IWUIC. Updates in year edition will be accomplished by an administrative standards update code change to be heard by the ADM Code Development Committee. WUIC5-13 504.10-WUIC-NICHOLAS WUIC6

WUIC6 13 505.2, Chapter 7 Proponent: Marcelo M. Hirschler, GBH International (gbhint@aol.com) 505.2 Roof covering. Roofs shall have at least a Class B roof assembly that complies with a Class B rating when tested in accordance with E 108 or UL 790 or an approved noncombustible roof covering. For roof coverings where the profile allows a space between the roof covering and roof decking, the space at the eave ends shall be firestopped to preclude entry of flames or embers, or have one layer of 72-pound (32.4 kg) mineral-surfaced, nonperforated cap sheet complying with D 3909 installed over the combustible decking. Add new standard to Chapter 7 as follows: E108-11 Standard Test Methods for Fire Tests of Roof Coverings UL UL 790-2004 Standard Test Methods for Fire Tests of Roof Coverings with revisions through October 2008 Reason: This is basically simple clarification, to clarify the test method for the Class B rating. It adds the same and UL standards contained in the IBC for the application. Cost Impact: None Analysis: The standards proposed for inclusion in the code, E108-07a and UL 790-2004, are currently referenced in the IBC. Updates in year editions will be accomplished by an administrative standards update code change to be heard by the ADM Code Development Committee. WUIC6-13 505.2-WUI-HIRSCHLER WUIC7

WUIC7 13 506.2, Chapter 7 Proponent: Marcelo M. Hirschler, GBH International (gbhint@aol.com) 506.2 Roof covering. Roofs shall have at least a Class C roof assembly that complies with a Class C rating when tested in accordance with E 108 or UL 790 or an approved noncombustible roof covering. For roof coverings where the profile allows a space between the roof covering and roof decking, the space at the eave ends shall be firestopped to preclude entry of flames or embers, or have one layer of 72-pound (32.4 kg) mineral-surfaced, nonperforated cap sheet complying with D 3909 installed over the combustible decking. Add new standard to Chapter 7 as follows: E108-11 Standard Test Methods for Fire Tests of Roof Coverings UL UL 790-2004 Standard Test Methods for Fire Tests of Roof Coverings with revisions through October 2008 Reason: This is basically simple clarification, to clarify the test method for the Class C rating. It adds the same and UL standards contained in the IBC for the application. Cost Impact: None Analysis: The standards proposed for inclusion in the code, E108-07a and UL 790-2004, are currently referenced in the IBC. Updates in year editions will be accomplished by an administrative standards update code change to be heard by the ADM Code Development Committee. WUIC7-13 506.2-WUIC-HIRSCHLER WUIC8