BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

Similar documents
BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

PLANS REVIEW CRITERIA - COMMERCIAL BUILDINGS

City of South Pasadena COMMUNITY IMPROVEMENT

Building Permit Application

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

HENDRY COUNTY BUILDING, LICENSING & CODE ENFORCEMENT

Village of Gurnee Construction Documents Submittal Requirements

Common Plan Review Rejection Reasons

Common Plan Review Rejection Reasons

UCC Permit Application Procedures

City of Oviedo Residential Permit Application Guidelines

Columbia County BUILDING DEPARTMENT Revised Jan 2018

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

BUILDING/STRUCTURE/TRADE

NOTE: For construction other than new commercial or additions (renovations), only those areas below describing the scope of work will be applicable.

4. Number of drawings required: ( ) Locations of nearest streets

CONSTRUCTION DOCUMENTS NECESSARY FOR PLAN REVIEW

KOCHVILLE TOWNSHIP REQUIRED INFORMATION FOR CONSTRUCTION PLAN REVIEW COMMERCIAL AND MULTI-FAMILY

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

Elko County Building & Safety Division

* RESIDENTIAL PLAN REVIEW *

Residential Building Inspections

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

Received by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:

HENDRY COUNTY BUILDING LICENSING & CODE ENFORCEMENT

7. Clearance with Suwannee River Water Management District - Surface water permit and DEP if property is in the National Wetlands.

CITY OF COOPER CITY BUILDING DEPARTMENT

One & Two Family Residential ADDITIONS

CODE COMPLIANCE PLAN REVIEW PROCEDURES

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

City of Pekin- Zoning and Inspections Department 111 S. Capitol Street, Pekin, Illinois (309)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist

APPLICATION FOR FINISHED BASEMENT PERMIT

CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS

Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2)

INSTRUCTIONS FOR COMPLETING THE BUILDING PERMIT APPLICATION FOR COMMERCIAL PROJECTS

BUILDING CODES & DESIGN CRITERIA

City of Omaha Plans and Permits Commercial Alterations and Conversions Building Permit Submittal Checklist

INTERNATIONAL CODE INTERPRETATIONS

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street

City Of Mendota Construction Procedures

CARBON MONOXIDE ALARMS

City of South Pasadena COMMUNITY IMPROVEMENT

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST

RESIDENTIAL REMODELING AND BASEMENT FINISH

Plan Submittal Checklist 2015 I-Codes

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

BUILDING PERMIT APPLICATION - MECHANICAL, PLUMBING, AND GAS

COMMERCIAL BUILDING PLAN REVIEW CHECKLIST

General Residential Code Requirements

Applications for building permits will not be reviewed until all of the required information has been submitted.

General Residential Code Requirements

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

FRANKLIN VILLAGE APARTMENTS Building I Franklin Street Morristown, NJ Block: 3901 Lots: 4,5,6

1 AND 2 FAMILY DWELLING REQUIREMENTS

AGREEMENT CONCERNING EXISTING AS BUILT CONSTRUCTION

COMMERCIAL PLANS SUBMITTAL CHECKLIST For Commercial and Multi-family (3 or more units) Building Permit Applications

General Requirements for Mobile Homes

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

GENERAL PLAN REVIEW REQUIREMENTS

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

International Code INTERPRETATIONS

Building Consent COMMERCIAL

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

General Building Information

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

TENANT IMPROVEMENTS GUIDE

Commercial and Residential Projects (after appropriate Board approvals have been made if necessary):

CITY OF CRANSTON RESIDENTIAL PERMIT PROCEDURE BASEMENT RENOVATION

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

General Residential Code Requirements

Town of Pawling Residential Building Permit Application

SINGLE FAMILY/DUPLEX/T.H. REPEAT PLAN APPLICATION

TOWN OF FRANCESTOWN BUILDING/CODE ENFORCEMENT 27 MAIN STREET P.O. BOX 5 FRANCESTOWN, NEW HAMPSHIRE Building Permit Application Guide

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

Training Certification Categories

LEAD DESIGN PROFESSIONAL:

Residential Building Plans

County of Yolo Development Services Building Inspection Division

WEST BRADFORD TOWNSHIP 1385 CAMPUS DRIVE DOWNINGTOWN, PA Phone (610) Fax (610)

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

THIS APPLICATION IS FOR NEW CONSTRUCTION OR RENOVATION OF ONE AND TWO FAMILY DWELLINGS.

City of Westerville Guide to Commercial Inspections

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

$ Plan Review Fee when Permit Application is submitted BASEMENT REMODEL BUILDING PERMIT APPLICATION. Status Sticker OFFICIAL USE ONLY

RESIDENTIAL BUILDING REQUIREMENTS

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

Oregon Building Officials Association

Transcription:

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL 32907 Phone: (321) 953-8924 Fax: (321) 953-8925 CUSTOMER SERVICE INFORMATION ON COMMERCIAL PLAN REVIEW REQUIRED DOCUMENTS MUST BE SUBMITTED AT TIME OF PERMIT APPLICATION Complete building permit application with subcontractors (master permit). Copy of Impact Fee receipts (Transportation and Utilities). Copy of recorded Notice of Commencement (if more than $2500 or $7500 for mechanical). Copy of workers compensation or exemption form. Copy of contractor licenses. Plumbing contractor authorization (if applicable). Electrical contractor authorization (if applicable). Mechanical contractor authorization (if applicable). Roofing contractor authorization (if applicable). One set of the approved City Site Plan. SPECIAL FLOOD HAZARD AREA IS THE PROPOSED STRUCTURE LOCATED IN A SPECIAL FLOOD HAZARD AREA? IF YES, PLEASE CONTACT THE CITY OF PALM BAY LAND DEVELOPMENT DIVISION AT (321) 733-3042 OR E-MAIL: floodzone@palmbayflorida.org GENERAL PLAN REQUIREMENTS Plans and specifications: Three (3) copies (additional copy may be required upon request) of drawings to scale with sufficient clarity and detail to indicate the nature and scope of work. Such drawings shall contain information in the form of notes or otherwise, as to the type of materials, and is essential to conform to technical codes of the Florida Building, Plumbing, Mechanical, Gas, Energy Efficiency, Accessibility, National Electrical Codes, and NFPA 101 Life Safety Code. Such information shall be specific and the technical codes shall not be cited as a whole or in part, nor shall the term legal or its equivalent be used as a substitute for specific information. All drawings, specifications and accompanying data shall bear the name and signature of the person(s) responsible for the design. Plans shall include a floor plan, foundation plan, wall sections, floor/roof system plan or truss layout with uplift values and all exterior elevations. Note: All plans shall be signed and sealed by Florida design professional. Note: A separate title indicating the name, address, telephone number and registration or license number of the person responsible for each system or design must be included on each submitted construction drawings. Occupancy group classification and Type of construction shall be noted on plan. 1 PLAN_REVIEW_INFORMATION_COMMERCIAL 03/12 Revision B

STEEL BUILDING REQUIREMENTS Three (3) copies of foundation anchor bolt plan shall be provided along with the pre-engineered building shop drawings. Shop drawings shall be signed and sealed by a professional and shall indicate the design criteria clearly, i.e. wind loading, floor and roof live and dead loads, etc. THE FOLLOWING INFORMATION RELATED TO WIND LOAD SHALL BE SHOWN ON THE CONSTRUCTION PLAN Basic wind speed according to the current Florida Building Code. Wind importance factor and building category. Wind exposure if more than one wind exposure is utilized, the wind direction shall be indicated. Applicable internal pressure coefficient. Components and cladding. The design wind pressure in term of psf (kn/m2) to be used for the design of exterior components and cladding materials not specifically designed by a registered design professional. CITY OF PALM BAY IS LOCATED IN WIND BOURNE DEBRIS AREA AND ONE OF THE FOLLOWING OPTIONS ON COMPILATIONS MAY BE USED FOR COMPLIANCE FOR WIND SPEED DESIGN CRITERIA Building may be designed as partially enclosed or opened. This means that the building design allows it to withstand the internal pressure build up when opening is breached. Plans must include a note stating, This structure has been designed as a partially enclosed structure in accordance with the Florida Building Code or Building may be designed as enclosed. This means that the glazed exterior openings shall be protected with the following options: Option 1: Plywood shutters may be used. The plywood must be a minimum of 7/16 inch thick, precut with anchorage system in place before the final building inspection, and all other panels shall be properly identified. (One shutter must be installed at final inspection.) Option 2: Approved shutter certified to meet impact tests. Plans must include manufacturer, model number, installation instructions and copy of impact test data. (One shutter must be installed at final inspection.) Option 3: Approved impact resistant windows certified to meet impact tests. Plans must include manufacturer, model number, installation instructions and copy of impact test data. FIRE RESISTANCE CONSTRUCTION REQUIREMENTS SHALL BE SHOWN AND INCLUDE THE FOLLOWING COMPONENTS Fire resistant separations. Fire resistant protection for type of construction. Protection of openings and penetrations of rated walls. Listed assemblies of rated walls, floor/ceiling and shaft enclosure (testing number). Fire blocking and draftstopping. Calculate fire resistance. Door and window schedule and their listing (rated assemblies). FIRE SUPPRESSION SYSTEM Early warning. Fire sprinklers. Smoke evacuation system schematic. Fire suppression system requires a separate permit. LIFE SAFETY SYSTEM SHALL BE DETERMINED AND SHALL INCLUDE THE FOLLOWING Occupant load and egress capacities. Early warning. Standpipe. Smoke control. 2 PLAN_REVIEW_INFORMATION_COMMERCIAL 03/12 Revision B

Stair pressurization. System schematic. Life safety plan. OCCUPANCY LOAD/EGRESS REQUIREMENTS INCLUDE THE FOLLOWING Occupant load and egress capacities. Means of egress (exit access, exits and exit discharge). Stair construction and protection. Emergency lighting and exit signs. Specific occupancy construction requirements. Horizontal exit/exit passageway. Door sizes. STRUCTURAL REQUIREMENTS SHALL INCLUDE THE FOLLOWING Structural design criteria clearly indicated, i.e. wind loading, floor and roof live and dead loads. Building envelope (shearwall locations, etc.). Structural calculations (new structure). Wall sections. Floor systems. Soil conditions/analysis. Post columns and beams. Foundation details. Roof system details. Threshold inspection plan and report (shoring drawing if applicable). Stair details to include tread and riser, handrail and guardrail. Hurricane tie downs, anchors and connector details. MATERIALS SHALL BE REVIEWED AND SHALL AT A MINIMUM INCLUDE THE FOLLOWING Wood. Steel. Aluminum. Glass. Masonry. Gypsum board/plaster. Type of insulation. Concrete. Plastic. Roofing. ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE FOLLOWING Site requirements showing handicapped parking. Accessible route. Vertical accessibility. Drinking fountains. Toilet and bathing facilities. Equipment. Special occupancy requirements. Fair housing requirements. Maneuvering clearances. Ramp rise and run. INTERIOR REQUIREMENTS SHALL INCLUDE THE FOLLOWING Interior finish (flame spread/smoke development). Light and ventilation. Sanitation. PLUMBING PLANS SHALL INCLUDE THE FOLLOWING 3 PLAN_REVIEW_INFORMATION_COMMERCIAL 03/12 Revision B

Minimum number of fixtures. Fixture requirements. Potable water supply piping. Sanitary and building drain. Water heaters and their locations. Vents. Location of water supply line. Grease trap sizes and location contact Utilities Department for size of grease traps at (321) 952-3410 or e-mail: pbutil@palmbayflorida.org. Plumbing risers. Roof drainage. Backflow preventer. Irrigation. Environmental requirements. MECHANICAL PLANS SHALL INCLUDE THE FOLLOWING Exhaust system including clothes dryers, kitchen equipment and specialty equipment system. Equipment schedule and their locations including rooftop units and GFIs. Duct sizes, insulation R-value, diffuser sizes, return air and plenum locations. Duct closures (UL181 approved tapes, mastic, etc.). Ventilation systems. Chimneys, fireplace and venting. Appliances. Refrigeration. Energy calculations (2-copies, signed and sealed). Make-up air. Combustion air. Boilers. Bathroom ventilation. GAS PLANS SHALL INCLUDE THE FOLLOWING Gas piping layout. Venting. Gas risers diagram, shut off and pipe sizes (isometric). Type of gas. Appliances including BTU s rating. Fireplaces. Chimneys and vents. LP tank locations. Combustion air. ELECTRICAL PLANS SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE AND SHALL INCLUDE THE FOLLOWING Type, location, grounding and capacity of all service equipment. Location of every proposed outlet including switches. Location, voltage, horsepower, kilowatt or similar rating of every motor or generator. Details of panelboard, switchboard and distribution center showing type and arrangement of switches, over current device and general equipment Panelboard or switchboard schedule showing wattage or amperage and the number of active or branch circuits to be installed and the number of spare or branch circuits for future use. Location of fire systems and exit lighting (emergency systems). Load calculation sheet. Special occupancies. 4 PLAN_REVIEW_INFORMATION_COMMERCIAL 03/12 Revision B

Low voltage. Communication systems. TERMITE PROTECTION PLAN MUST SPECIFY TYPE OF TERMITE TREATMENT Soil chemical barrier method Other treatment must specify the proposed method and submit documentation that substantiates the proposed method Include a note on the plan stating: Chemical barrier method shall be completed in accordance with the Florida Building Code. Include a note on the plan stating: A Certificate of Compliance shall be provided to the Building Division before issuance of a Certificate of Occupancy. EXTERIOR WINDOWS AND DOORS ARE REQUIRED TO MEET THE DESIGN WIND LOAD PRESSURES All exterior windows and glass doors are required to be tested by an approved independent testing laboratory in accordance with the Florida Building Code and shall bear an AMMA or WDMA label identifying the manufacturer, performance characteristics and approved product testing entity. Plan details illustrate that all exterior windows and doors shall be anchored per published manufacturer s recommendations to achieve the design pressure specified. Plan details illustrate that all exterior windows and doors where buck thickness is less than 1 ½ inches, shall be anchored through the jam into the structural substrate. Plan details illustrate that all exterior windows and doors where buck is less than 1 ½ inches or greater, the buck must be attached in a manner that transfers the load directly to the structure. Windows and doors shall be anchored through the jam into the wood buck. Plan details illustrate that the tapered window buck shall extend beyond the interior lip of the window. Plans details illustrate that mullions and adjacent door assemblies are required to be tested or engineered to transfer 1.5 times the designed loads to the rough opening substrate. A complete door and window schedule including manufacturer and model number has been included as part of the construction drawings. Garage door installation details and data indicating compliance with the wind load requirements of the Florida Building Code has been included as part of the construction drawings. 5 PLAN_REVIEW_INFORMATION_COMMERCIAL 03/12 Revision B