LENTON INTERLOK. The Splicing Solution for the Precast Concrete Construction Industry

Similar documents
-165 C / -265 F CRYOGENIC REBAR SPLICING SYSTEMS

CADWELD Rebar Metal Filled Mechanical Splices

LENTON TERMINATOR FOR REBAR ANCHORAGE

Wind Power Solutions

CADWELD Welded High-Voltage Power Connections. For Underground and Subsea Cable Splicing

Originally Issued: 02/02/2009 Revised: 11/09/2017 Valid Through:02/28/2019

Originally Issued: 02/02/2009 Revised: 07/27/2018 Valid Through: 02/28/2019

ERICO SYSTEM ESE Lightning Protection Products

BUILDING STRENGTH TAPER-LOCK REBAR THREADING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

CITY OF LOS ANGELES CALIFORNIA

Bracing Systems. Available At VIKING SA Tel: (+352) Fax: (+352)

DYWIDAG Cable Bolts for Mining

Taper Threaded Rebar Splicing Systems

PERFORM WITH PRECISION TAPER-LOCK REBAR THREADING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

Contents. DYWIDAG Tie Rods DYWIDAG Threadbar Tie Rods... 4 GEWI Steel Waling Tie Rods... 6 DYWIDAG Tie Rods with Strand Tendons...

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SPLICE SLEEVE JAPAN, LTD.

Originally Issued: 09/16/2010 Revised: 09/15/2017 Valid Through: 09/30/ Design:

Reinforcement Couplers As An Alternative To Lap Splices: A Case Study

SEISMIC SWAY BRACING

Originally Issued: 09/16/2010 Revised: 05/17/2018 Valid Through: 09/30/2019. ACI , -08, or -05, the head is considered part of the bar.

Tapes, Fasteners & Sealants. Product Information Guide. The right solutions. The right products.

CT-Bolt Combination Rock Bolt

The Hashemite University Department of Civil Engineering. Dr. Hazim Dwairi. Dr. Hazim Dwairi 1

ERICO SYSTEM 1000 ESE LIGHTNING PROTECTION PRODUCTS

UCL Series Underwater Small Lighting Niche

Steel Fiber Reinforcing

Wabo Modular STM and D Series Large movement expansion joint system

WORKFORCE METRICS BENCHMARK REPORT

HIGH PERFORMANCE REINFORCEMENT PRODUCTS. Product Catalogue.

TAPER THREADED REBAR SPLICING SYSTEMS

BS EN :2004 EN :2004 (E)

MODULAR SERVICE AGREEMENTS THE KEY TO CONTINUOUS PERFORMANCE. SICK LifeTime Services

CARES Technical Approval Report TA1C

TECHNICAL DESIGN AND INSTALLATION GUIDE THE COMPLETE ENGINEERED SOLUTION FOR TEMPORARY MOVEMENT JOINTS

WE ARE YOUR SOLUTION TO REBAR CAGE ALIGNMENT!

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

Originally Issued: 04/18/2014 Revised: 05/02/2018 Valid Through: 04/30/2019

In-plane testing of precast concrete wall panels with grouted sleeve

Wind Power Solutions CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER

Precision Roller Pinion System Models RPS16, RPS20, RPS25, RPS32, RPS40 LINEAR MOTION CONTROL PRODUCTS FORM NO. L A-1204.

SECTION CONCRETE REINFORCEMENT

MODELS: SM & SMSS

Use of BS 5400: Part 4: 1990

CARES Technical Approval Report TA1-B 5064

CI/SfB (29) Et6. October Starter Bar System for the Construction Industry

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD.

hp hardware support onsite global next day response

Aero Tec Models 700 & 750 (115 vac)

Installation and Use Instructions for the Big Ass Workbench Manufactured by Mercer Innovation, LLC

Section REINFORCING STEEL

Stretch Wire. P/N Rev. 2. IOM Stretched wire festoon manual

Originally Issued: 11/24/2010 Revised: 01/20/2017 Valid Through: 11/30/ Design

Development Length, Lap Splices and curtailment of reinforcement

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

Originally Issued: 08/22/2014 Revised 03/10/2017 Valid Through: 08/31/2017

INVISIBLE CONNECTIONS

PRECAST CONCRETE CONNECTIONS - US PRACTICE

CARES Technical Approval Report TA1-B 5061

CONSTRUCTION SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

TAPER THREADED GRIP-TWIST

CI/SfB Et6. September Stainless Steel Reinforcement for the Construction Industry

Lecture 13 CONCRETE WORKS

CARES Technical Approval Report TA1-B 5058

defense manufacturers

Pressure Sensitive Adhesives for HVAC/R, Mechanical and Metal Building Insulation. Tapes, Fasteners & Sealants Product Catalog

Precast concrete is significantly being used in earthquake

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

PEN SEAL. Pipe Penetration Seals

HD Firewall Mount 850 all, S/V , C ipd #

CARES Technical Approval Report TA1-B 5065

PileForm F. Pile Jacket Installation Guide FiveStarProducts.com TECHNICAL SUPPORT

PI /09 Dedicated to improving vehicle fun, safety & performance

EAST WEST ENGINEERING INSTRUCTION MANUAL. Type FJA T Telescopic Extension JIB Attachment. Table of contents. 1) Quality Policy Statement 2

AIR CHAMP PRODUCTS. Micro Clutch and Micro Brake FORM NO. L J-0110

SUMMARY SHEETS OF GROUTED DUCT CONNECTIONS

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER:

Mechanical Splicing Couplers for Reinforcement

Technical Notes. Mandatory Barrier Cable Inspection Requirements

MODELS: 24 SM & 24 SMSS

Festoon Manual Stretch Wire

HRC T-Headed Bars Advantages for the user

TERWA REBAR CONNECTION COUPLERS

Accelerated Bridge Construction in USA

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

Series 5500 Bellows Pump Connectors Catalog 474E

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

Civil Engineering Construction I (CBE5031)

nvent CADDY Pyramid Anchoring System

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004

World Engineering Congress 2010, 2 nd 5 th August 2010, Kuching, Sarawak, Malaysia Conference on Engineering and Technology Education

600 SERIES FOUNDATIONLESS JIB CRANE MANUAL ADDENDUM

Consolidated * Parts Engineered to Perform

YOUR LITE-DECK SECTIONS

Symons Soldier DAYTONSUPERIOR.COM FORMING. Versatile Soldier Beam System

POST-TENSIONED SLABS SPECIALISED ENGINEERED SOLUTIONS FOR STRUCTURES.

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

DIVISION: CONCRETE SECTION: POST-TENSIONED CONCRETE REPORT HOLDER: GENERAL TECHNOLOGIES, INC.

FOR SALE / LEASE 420,000 SF AC

Instructions For Use USD3144. Pall Microdisc Filter Capsules with Pegasus Protect Prefilter Membrane

Transcription:

LENTON INTERLOK The Splicing Solution for the Precast Concrete Construction Industry

How to Specify By Name: Mechanical splices shall be LENTON INTERLOK, manufactured by ERICO. Generic: Mechanical reinforcing steel splices shall meet building code requirements of developing in tension and compression as required by *. The sleeve shall be produced as a casting from ductile iron conforming to ASTM A536 standards. One end of the sleeve shall consist of a positive locking tapered thread, while the opposing cylindrical side is designed with equally spaced concentric ribs. Grouting must be performed in accordance with the manufacturers recommended installation procedures. *as required by local norms/codes P roduct Specs Rebar Size Designation Number of Part Art. "A" "B" "C" "D" "E" in-lb Metric Canadian couplers per bag No. No. in mm in mm in mm in mm in mm of HY10L grout #5 16 15M 23 LK5 7-5/8 195 2-7/16 62 6-1/8 156 7/8 22 1-7/8 48 #6 20 20M 25 LK6 145580 7-5/8 195 2-7/16 62 6-1/8 156 1-1/8 29 1-7/8 48 #7 22 26 LK7 145585 7-5/8 195 2-7/16 62 6-1/8 156 1-1/4 32 1-7/8 48 #8 25 25M 21.5 LK8 145590 8-5/8 219 2-5/8 67 7 178 1-3/8 35 2 51 #9 28 30M 17.5 LK9 145595 9-3/4 248 2-3/4 70 8 203 1-1/2 38 2-1/8 54 #10 32 14 LK10 145600 10-13/16 275 2-15/16 75 9 229 1-9/16 40 2-5/16 59 #11 36 35M 12 LK11 145605 12 295 3-1/8 79 9-7/8 251 1-11/16 43 2-7/16 62 40 7.5 LKT14SP 145610 15 381 3-11/16 94 12-3/4 324 2-3/8 56 2-3/4 70 #14 43 45M 7.5 LKT14 15 381 3-11/16 94 12-3/4 324 2-1/8 54 2-3/4 70 50 5 LKT18SP 145615 20-5/16 508 4-1/2 114 17 432 2-3/4 71 3-1/4 83 #18 57 55M 5 LKT18 145620 20-5/16 508 4-1/2 114 17 432 2-3/4 72 3-1/4 83 The system is designed to meet or exceed the ACI, UBC, and IBC codes for Type 1 and Type 2 mechanical connections. The system also meets the requirements of BS 8110, BRL 504, and Hong Kong GS, in addition to other worldwide codes. WARNING ERICO products shall be installed and used only as indicated in ERICO s product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILI- TY OR FITNESS FOR A PARTICULAR PURPOSE), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyer's receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer. THE FOREGOING STATES BUYER S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICO's employees. Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUEN- TIAL LOSS OR DAMAGE INCURRED BY BUYER.

ERICO has been a pioneer in the concrete construction industry for more than 40 years. We changed rebar splicing, first with CADWELD mechanical connections, then with the LENTON taper threaded rebar splicing system. ERICO now offers a wide range of mechanical splices for almost any construction need: CADWELD Premier mechanical splicing system LENTON FORM SAVER Ideal for segmental pour LENTON INTERLOK Ideal for precast structures LENTON STEEL FORTRESS Ideal for punching shear reinforcement LENTON QUICK WEDGE Ideal for quick retrofit LENTON SPEED SLEEVE Ideal for compression only splice LENTON TERMINATOR Ideal alternative to hooked rebar anchorage LENTON LOCK Ideal for insitu splicing The entire LENTON line of mechanical rebar splices has replaced many conventional splicing systems, such as welding and lap splicing. Unlike butt welding, ERICO products require no special training or external power source, are quicker to install and inspect, reduce crane time, improve the tensile strength of the splice and can be installed in any weather. As your rebar splicing specialist, ERICO offers you the expertise you need for all your rebar splicing projects. The LENTON INTERLOK provides a cost effective and quick option with a dramatic increase in design flexibility of precast concrete elements. ERICO's growing project portfolio stands testament to the advantages provided by the system. LENTON INTERLOK has been used in construction of parking structures, hospitals, high rises, stadiums, bridges, air traffic control towers and many other types of projects. The Rebar Splicing Solution Construction in precast concrete is gaining popularity worldwide. Structures which were previously made only with cast-in-situ concrete are now being constructed using precast concrete. To facilitate this process, special rebar splicing systems are needed to increase the structural integrity of precast concrete constructions. As a leader in reinforcing bar splicing, ERICO has developed the LENTON INTERLOK system as the solution to creating rebar continuity between precast concrete elements. The LENTON INTERLOK can connect #6 (20mm) through #18 (57mm) rebar using the LENTON taper threaded system and a special high strength grout. The result is a full strength splice that is reliable, forgiving to rebar misalignment and, as no closure pour is required, undeniably efficient. Architects and engineers are now afforded previously unattainable flexibility in the design and application of precast concrete elements, while gaining efficiencies in construction time, cost and aesthetics. Load bearing applications such as columns, beams and shear walls can now be efficiently incorporated into projects using segmental precast construction techniques, where previously, only structural steel or cast-in-situ concrete would have been considered.

Benefits of LENTON INTERLOK: Helps ensure structural integrity between the precast sections. Provides load path continuity of the reinforcement, acting as one continuous bar. Designed for all high yield deformed rebar sizes from #6 to #18 (20mm to 57mm). Eliminates field welding damage to concrete Helps to overcome rebar misalignment problems in joining of precast concrete members. Offers a higher strength connection between the precast elements than traditional joining methods. Eliminates costly and unsightly patchwork. No closure pours required between adjacent members. Tensile loads are transferred through the rebar, and are not dependent on the compressive strength of the concrete. Optimizes production time and is convenient and flexible to use. for the Precast Concrete Construction Industry How to Install The LENTON INTERLOK couplers are fastened to the rebar and placed into the precast forms. Easy-to-use, reusable form-mounting fixtures are available for this purpose. The LENTON INTERLOK incorporates a taper thread which creates a positive lock that seals the coupler. This threaded system aids the alignment of the coupler onto the rebar, providing a full strength mechanical connection in both tension and compression. The splice is completed on site by inserting the exposed dowel of the adjoining structural member into the sleeve and filling the coupler with HY10L high strength grout from ERICO. This can be either poured or pumped into the sleeve. The inlet and outlet ports on the sleeve accept commonly available rigid PVC or flexible plastic tubes. Standard 1/2" (13mm) and 3/4" (19mm) PVC or flexible tubing is used for the inlet and outlet ports. The taper threaded sleeve keeps the bar in axial alignment to increase field tolerance of the rebar dowels. The complete splice provides load path continuity allowing precast structures to function as continuous members. A detailed installation guide is available from ERICO outlining correct installation, grout mixing and formwork mounting procedures. LENTON INTERLOK grout (HY10L), can be pumped or poured into the sleeves at the jobsite.

A pplications Column to Column Columns to Foundations Shear Walls to Foundations Shear Wall to Shear Wall Panel to Panel Walls to Floor Slab Architectural Panels Projects I-95 Fuller Warren Bridge; Jacksonville, Florida USA Pacific Plaza Office Complex; San Francisco, California USA Houston International Air Traffic Control Tower; Houston, Texas USA Olympic Stadium; Atlanta, Georgia USA Taj Mahal Casino Parking Garage; Atlantic City, New Jersey USA Corcoran Prison; Corcoran, California USA Arena Central; Birmingham UK Salamenca Street; London UK Office Development; Dartford, Kent UK Sydney Stadium; Sydney Australia Mazeikiu Nafta Refinery; Mazeikiai Lithuania Terminal 5; Heathrow Airport UK One Hyde Park Apartments; London UK Athlete s Village London 2012 Olympics; Stratford City, London UK Highbury Square; London UK Grout-filled connection designed for moment capacity in precast construction.

www.erico.com AUSTRALIA Phone 1-800-263-508 Fax 1-800-423-091 CHINA Phone +86-21-3430-4878 Fax +86-21-5831-8177 HUNGARY Phone 06-800-16538 Fax +39-0244-386-107 NORWAY Phone 800-100-73 Fax 800-100-66 SWITZERLAND Phone 0800-55-86-97 Fax 0800-55-96-15 BELGIUM Phone 0800-757-48 Fax 0800-757-60 DENMARK Phone 808-89-372 Fax 808-89-373 INDONESIA Phone +62-21-575-0941 Fax +62-21-575-0942 POLAND Phone +48-71-349-04-60 Fax +48-71-349-04-61 THAILAND Phone +66-2-267-5776 Fax +66-2-636-6988 BRAZIL Phone +55-11-3623-4333 Fax +55-11-3621-4066 FRANCE Phone 0-800-901-793 Fax 0-800-902-024 ITALY Phone 800-870-938 Fax 800-873-935 SINGAPORE Phone +65-6-268-3433 Fax +65-6-268-1389 UNITED ARAB EMIRATES Phone +971-4-881-7250 Fax +971-4-881-7270 CANADA Phone +1-800-677-9089 Fax +1-800-677-8131 GERMANY Phone 0-800-189-0272 Fax 0-800-189-0274 MEXICO Phone +52-55-5260-5991 Fax +52-55-5260-3310 SPAIN Phone 900-993-154 Fax 900-807-333 UNITED KINGDOM Phone 0808-2344-670 Fax 0808-2344-676 CHILE Phone +56-2-370-2908 Fax +56-2-369-5657 HONG KONG Phone +852-2764-8808 Fax +852-2764-4486 NETHERLANDS Phone 0800-0200-135 Fax 0800-0200-136 SWEDEN Phone 020-790-908 Fax 020-798-964 UNITED STATES Phone 1-800-753-9221 Fax +1-440-248-0723 Copyright 2007, 2010 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. CP7C-WWEN C689LT10WWEN 05M0810