INNOVATIVE BIOMARKER SOLUTIONS One tube. Any lab. For Research Use Only. Not Intended for Use in Diagnostic Procedures. TruCulture is covered by the following patents: US641334B1, AU199954193A, EP112988A2, AT3845T, DE59912716D1 MyriadRBM.com/TruCulture
TruCulture Blood Collection and Whole Blood Culture System (RUO) The immune system is a complex, multi-layered signaling network comprised of multiple modulating components and cell types. This intricate system provides sensitive and specific responses to stimuli. Responses can vary greatly between individuals, yet patterns for a single individual have shown to be remarkably consistent. These patterns are sometimes masked by variables that can be attributed to sample collection and manipulation methods. Researchers require an in vitro model that preserves physiological cellular interactions, and allows for easy measurement(s) of the immune system with and without stimulation. In order to ensure reliable data, the system must also be reproducible. The TruCulture System is designed to capture immune cell activity without introducing sample collection and manipulation variables. The system employs a single, self-contained tube for whole blood collection and culture. Things should be made as simple as possible, but not any simpler ~ Albert Einstein
TruCulture Procedure Exactly 1 ml of blood is drawn directly into the TruCulture tube, instantly cultured and then incubated in a dry heat block at 37 C for up to 48 hours. A valve is then inserted to manually separate the supernatant from the cells for subsequent downstream analysis. 1 COLLECT 2 INCUBATE 3 ANALYZE The procedure requires less than 5 minutes hands on time, no specialized laboratory equipment and can be performed by any person trained in phlebotomy. TruCulture Advantages What it is/does Integrated blood collection device and whole blood culture system Closed system Simple to use by any trained phlebotomist Reliable, reproducible Utilizes general purpose laboratory equipment Available with and without a variety of stimulants; customizable What it is not/does not do Partition monocytes from other whole blood components including granulocytes, platelets and red blood cells Artificial, open system requiring transfer of specimen to another tube. Require multiple steps; laborious Variable Require centrifuge or specialized laboratory or personnel One tube. Any lab.
Reproducibility of the TruCulture System One of the most difficult aspects of accurately measuring leukocyte response is the variability of results due to the complexity inherent in the immune system. IFNg IL-5 IL-6 DAY A B C A B C A B C 1 6844 193119 39273 98 188 5 32347 1248 18167 9 65366 221443 483 84 242 52 29497 1156 19914 17 6913 18517 27752 85 223 42 328 176 14638 25 726 18784 33815 13 246 42 315 146 19741 MEAN 66956 196893 35417 93 225 46 3967 128 18115 Therefore, it is imperative that the in vitro system SD 532 16697 593 9 26 496 1421 1389 2447 is consistent, and does not introduce artifacts that CV% 8% 8% 17% 1% 12% 11% 5% 11% 14% would result in incorrect conclusions. IFNgamma IL-5 IL-6 25 3 35 The graphs to the right show immune system 25 3 2 2 25 15 2 15 response to LPS/SEB at four different time points up 1 15 1 1 5 5 5 to 25 days, for three different donors (A, B and C) 1 9 17 25 1 9 17 25 1 9 17 25 measured for three different cytokines (IFNγ, IL-5 and day of trial day of trial day of trial IL-6). As expected, the immune response is variable between individuals. However, the data shows very consistent measurements within an individual with whole blood collected and cultured using TruCulture. In summary, the TruCulture tubes show consistent and reliable results, with CVs ranging from 5 to 14% for each data point. TruCulture versus PBMC The graph below represents preliminary data comparing immune cell responses with and without stimulation of an individual donor for TruCulture System versus PBMC cultures. In general, the response of immune cells cultivated in TruCulture mirrors that of PBMC for the majority of the cytokines measured; however, in this individual measurable stimulation is observed with TruCulture for cytokines such as IL-12p7 and IL-23, whereas no or negligible stimulation is observed with PBMC cultures. By providing a more inclusive set of cellular components, TruCulture is able to show a more complete and more physiological picture of cytokine activation versus PBMC. Donor A TC stim TC null PBMC stim PBMC null 7 6 5 4 3 2 1 G-CSF GM-CSF IL-1alpha IL-1beta IL-1ra IL-2 IL-4 IL-5 IL-6 IL-7 IL-8 IL-1 IL-12p7 IL-13 IL-16 IL-17 IL-18 IL-23 MCP-1 MDC MIP-1alpha MIP-1beta TGF-alpha TNF-alpha TNF-beta MyriadRBM.com/TruCulture
Mechanical Breakaway Plunger (transforms the syringe into a culture tube, no centrifugation required) Sarstedt Monovette Tube (prevents cells from adhering to walls) Sarstedt Safety-Multifly Needle Screw Cap (easy harvesting) Stopper (prevents injection of the culture medium) Proprietary Culture Medium (allows incubations up to 48 hrs.) Rubber Seal (closed system, before and after blood draw, reduces risk of sample contamination) SERAPLAS Valve and Plunger (separates the supernatant from the cells, no centrifugation required) Ordering TruCulture TruCulture tubes are provided with or without a stimulant. The table below describes the stimulants that are currently available, and the cells that are targeted by those stimulants. Custom stimulant TruCulture tubes are also available. Please inquire. Null Tubes do not contain any stimulants and may be utilized for experimental control. Ready to Order Stimulants Lipopolysaccharide (LPS) LPS + SE-B Made to Order Stimulants Anti-CD-3 antibody Anti-CD3 antibody + Anti-CD28 antibody Staphylococcal Enterotoxin type B (SE-B) Staphylococcal Enterotoxin type B (SE- B) + Anti-CD28 antibody Zymosan Major Target Cells Monocytes, T-cells Monocytes, T-cells and Th1>>Th2 Major Target Cells Th1>Th2 (~ 1 out of 6 donors does not respond to this type of stimulus in whole-blood) Th1, Th2, regulatory T cells (~ 1 out of 6 donors does not respond to this type of stimulus in whole-blood) Th1>>Th2 Th1>Th2 Granulocytes, monocytes If you are interested in adding a custom compound or placing an order for TruCulture, please contact your local sales representative, or e-mail us at info@myriadrbm.com.
Myriad RBM 33 Duval Road Austin, Texas 78759 P 512 835 826 Toll-free 866 RBM MAPS (726 6277) F 512 835 4687 info@myriadrbm.com www.myriadrbm.com REV 2