CEL212 Environmental Engineering

Similar documents
METHOD #: Approved for NPDES (Issued 1971) Oxygen, Dissolved (Modified Winkler, Full-Bottle Technique) ANALYTE: CAS # O Oxygen

SOP_Chem_001 Chemical Analysis_ Chemical Oxygen Demand. Standard Operation Procedure Chemical Oxygen Demand Closed Reflux, Titrimetric Method

Application Notes for COD Analysis DETERMINATION OF CHEMICAL OXYGEN DEMAND (COD) IN WATER AND WASTE WATER.

Standard Methods for the Examination of Water and Wastewater

Oxygen Demand, Chemical

Oxygen Demand, Chemical

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

MAHATMA GANDHI MISSION S JAWAHARLAL NEHRU ENGINEERING COLLEGE, AURANGABAD. (M.S.)

3. Add 0.4 ml of. 7. Use a TenSette

Applications of Oxidation/Reduction Titrations. Lecture 6

3. Add 0.4 ml of. 7. Use a TenSette

OXIDATION-REDUCTION TITRATIONS-Permanganometry

Oxygen Demand, Chemical

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

Oxygen Demand, Biochemical

Auburn University Department of Civil Engineering Introduction to Environmental Engineering CIVL Laboratory #6 Chemical Oxygen Demand (COD)

Oxygen Demand, Chemical

EXPERIMENT III. Determination of Iron in Iron Oxide, (Fe 2 O 3 ), Using Dichromate Method. Chemical Overview

T 619 cm-84 TENTATIVE STANDARD 1933 OFFICIAL STANDARD 1935 CORRECTED 1944 CORRECTED 1953 CLASSICAL METHOD TAPPI. Analysis of salt cake

Sustainable waste water treatment. reuse option for commercial and residential buildings

Determination of Ferrous Iron in EASTMAN Color Films, KUL Bleach

Measuring Dissolved Oxyg Instructions for the La Motte Field-Test Kit

What is: (a) aqua fortis, (b) aqua regia (c) Fixation of Nitrogen?

TREATMENT OF DAIRY WASTE WATER BY MORINGA OLEIFERA AS NATURAL COAGULANT

Lab #7: Redox Titration Lab Exercise Chemistry II 10 points Partner: USE BLUE/BLACK INK!!!! Date: Hour:

Physico-Chemical Analysis of Ground Water and Waste Water taken from Different Blocks of Mungeli District (C.G.)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T223.

COD. Environmental Chemistry Chemical Oxygen Demand A Conventional Perspective Lecture 8

MS20 Laboratory: Physical and Biological Factors Affecting Oxygen in Sea Water

TITANIUM DIOXIDE. SYNONYMS Titania; CI Pigment white 6; CI (1975) No ; INS No. 171 DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

SurTec 609 EC Pre-Treatment prior to E-Coat

Some Basic Concepts of Chemistry

CE3502. ENVIRONMENTAL MONITORING, MEASUREMENTS & DATA ANALYSIS

Method 8.10 Refined sugar: sulphite (SO 2 ) by the Rosaniline method

PRECAUTIONS WHILE PERFORMING CHEMISTRY ACTIVITIES. Do not touch anything without the permission of the teacherin the lab.

SUMMARY OF STANDARDS FOR WATER ANALYSIS ON COURSE WAT-E2120 SPRING 2017

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Instrument Adapters Light shield DR 6000, DR 5000 DR 3900 LZV849 DR 3800, DR 2800 LZV646 DR or (A)

Distillery Wastewater Decontamination by the Fenton Advanced Oxidation Method

Partner: Cathy 22 March Separation and Qualitative Determination of Cations and Anions

Environmental Chemistry - Water HL

DETERMINATION OF HARDNESS IN A WATER SAMPLE

Joe DiPietro Central Catholic High School 11 th grade

Potentiometric analysis of brass and bronze plating baths

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh

COPPER CYCLE EXPERIMENT 3

CIRCUPOSIT 71 Full Build Electroless Copper Nitrate Bath (Generic Concentrates) For Electronic Finishing Applications

Reactivity Series. Question Paper. Cambridge International Examinations. Score: /39. Percentage: /100

1601 Redox Titration

LAD B3 (pg! 1 of 6! ) Analysis by Redox Titration Name Per

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835

WET ANALYSIS OF GOLD-SILVER ALLOYS OF HIGH GOLD CONTENT 1

A Cycle of Copper Reactions

POTASSIUM PERMANGANATE AS OXIDANT IN THE COD TEST FOR SALINE WATER SAMPLES

Nitrogen, Simplified TKN (s-tkn )

Physico chemical analysis of Aquarium water and Narmada River water

Experiment 3: Determination of an Empirical Formula

Analysis of dissolved nitrite (NO 2- )

4831 S. Whipple Avenue Chicago IL Phone: Fax:

(aq) + 5e - Mn 2+ (aq) + 4H 2

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

TAML Process Effluent Effect on Aquatic Productivity. Joe DiPietro Central Catholic High School 11 th grade

Chemical Oxygen Demand Flow Rate Effect on Total COD and the Particulate/Soluble COD Ratio

Lecture 4 Water Quality Monitoring: Collection of water samples & estimation of physical parameters

Experiment 18 Determination of Iron by Visible Spectrophotometry

DRAFT UGANDA STANDARD

PREPOSIT Etch 748. For PWB Metallization Applications. For use in the CIRCUPOSIT 3000 Process. Bath Make-up Metric (for 100 liters)

Respirometric BOD 5 determination of waste water polluted with organic or inorganic toxins or inhibitors. OxiTop pressure measuring heads

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

COPPER GLEAM RG 11 Acid Copper Plating Process

QUALITY ASSESSMENT of WATER and WASTEWATER

NACA Laboratory Equipment and Supplies

[ Cl ] - [[Mg 2+ ] ] Experiment 7: Oxidation-Reduction Reactions. transfer e -

Nitrogen, Simplified TKN (s-tkn ) DOC

TYPES OF CHEMICAL REACTIONS PART I INTRODUCTION

Comparative Study of BOD and PH of Distillery Wastewater

Duncan. UNIT 8 - Chemical Equations BALANCING EQUATIONS PRACTICE WORKSHEET 14.) C2H6 + O2 CO2 + H2O. 2.) Na + I2 NaI 3.) N2 + O2 N2O 4.

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA

The following are the completed but unbalanced equations. Each equation is numbered to match each step of the cycle:

SOP-C-101 Determination of Biochemical Oxygen Demand

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits

Determination of Total Kjeldahl Nitrogen (TKN) in Water and Waste Water using 500 ml Sample Tubes

USEPA 1 Periodate Oxidation Method 2 Method to 20.0 mg/l Mn (HR) Powder Pillows

Surface Water Samples: Containers, Preservation and Hold Times Table

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

SurTec 712 Alkaline Cyanide-Free Zinc/Iron Process

Alternate Test Procedure #N In-Situ Inc. Method Carbonaceous Biochemical Oxygen Demand (CBOD) Measurement by Optical Probe

KEYWORDS: Adsorption, Chromium(VI), COD, Tannery Effluent, Banyan Sawdust.

Copper Odyssey. Chemical Reactions of Copper

The ion with Vanadium in its oxidation state of 5 exists as a solid compound in the form of a VO 3

Compiled by Rahul Arora What do you mean by corrosion? How can you prevent it?

iafor The International Academic Forum

FerroVer Method (Powder Pillows or AccuVac Ampuls) USEPA approved for reporting wastewater analysis (digestion is required; see Section 2 * )

Corn Starch Analysis B-58-1 SULFUR DIOXIDE

ICSE-Science 2 (Chemistry) 2004

Activity of metals SCIENTIFIC. Demonstration and Inquiry. Introduction. Concepts. Background. Inquiry Approach. Demonstration Questions

Phosphorus, Reactive (Orthophosphate)

Transcription:

Page 1 Indian Institute of Technology Delhi CEL212 Environmental Engineering Second Semester 2012-13 (Dr. Arun Kumar; arunku@civil.iitd.ac.in) Laboratory 7: Biochemical Oxygen Demand (BOD) and Chemical Oxygen Demand (COD) 7A: Biochemical Oxygen Demand (BOD) Objective : To determine BOD value for determining biodegradability of solution. Background: The most widely used test indicating organic pollution of both wastewater and surface water is the 5-day BOD (BOD 5 ). This determination involves the measurement of the dissolved oxygen used by microorganisms in the biochemical oxidation of organic matter. BOD 5 is the total amount of oxygen consumed by microorganisms during the first five days of biodegradation. Oxygen demand is associated with the biodegradation of the carbonaceous portion of wastes and oxidation of nitrogen compounds such as ammonia. The following equations simplify the process of biodegradation: Organic matter + O 2 + microorganisms CO 2 + H 2 O + new microbial cells Ammonia + O 2 + microorganisms NO 3 + H 2 O + new microbial cells Procedure: Apparatus: Incubation bottle 300mL volume; Air compressor, 20 C incubator Reagents for DO measurement: 1. Manganese sulfate solution: Dissolve 480 g MnSO 4.4H 2 O, 400 g MnSO 4.2H 2 O or 364 g MnSO 4.H 2 O in distilled water, filter, and dilute to 1L. The MnSO 4 solution should not give a color with starch when added to an acidified potassium iodide (KI) solution. 2. Alkali-iodide-azide reagent 3. Sulfuric acid: One ml is equivalent to ~ 3mL alkali-iodide-azide reagent. 4. Starch solution: Dissolve 2 g laboratory-grade soluble starch and 0.2 g salicyclic acid as preservative in 100 ml hot distilled water. 5. Standard sodium thiosulfate titrant: Dissolve 6.205 g Na 2 S 2 O 3. 5H 2 O in distiller water and add 1.5 ml 6N NaOH or 0.4 g solid NaOH and dilute to 1000 ml. Standardize with biiodate solution. 6. Standard potassium bi-iodate solution (0.0021M): Dissolve 812.4 mg KH(IO 3 ) in distilled water and dilute to 1000 ml. 7. Standardization: Dissolve e ~ 2 g KI, free from iodate in an Erlenmeyer flask with 100 to 150 ml distilled water; add 1 ml 6N H 2 SO 4 or a few drops of conc. H 2 SO 4 and 20.00 ml standard bi-iodate solution. Dilute to 200 ml and titrate librated iodine with thiosulfate titrant, adding starch toward end of titration, when a pale straw color is reached. When the solution is of equal, 20.00 ml 0.025M Na 2 S 2 O 3 should be required. If not, adjust the Na 2 S 2 O 3 solution to 0.025M.

Page 2 Steps: DO measurement: 1. Make dilution water by adding 2mL/L of following reagents in distilled water: a. Phosphate buffer solution b. Magnesium sulfate solution c. Calcium chloride solution d. Ferric chloride solution e. Sodium Sulfite solution 2. For a given sample bottle, add 1 ml of alkali azide and then 1 ml manganous sulfate solution. Shake well the bottle and keep it open for 5 minutes to settle the precipitate. Add 2 ml concentrated H 2 SO 4 and place the cap on the bottle. Shake well the bottle till all the precipitate is dissolved. 3. Take 203 ml of sample in conical flask and titrate with standard sodium thiosulfate solution (0.025N) till the colour changes from dark yellow to light yellow. Then add few drops of starch indicator and continue to titrate till the color of the solution becomes either colorless or changes to its original sample colour. Note down volume of 0.025N sodium thiosulfate consumed. 4. Calculate DO value of the sample. Remember that in 200 ml sample, 1 ml of sodium thiosulfate of 0.025N equals to 1 mg/l dissolved oxygen: =>Dissolved oxygen (DO) (in mg/l) = ml of sodium thiosulfate (0.025N) consumed. BOD: 1. Prepare BOD dilutions. Use dilution water (it contains nutrients, the exact contents are described in Standard Methods):Blank (only dilution water);5 ml sample in 300 ml BOD bottle, fill up with dilution water;15 ml sample in 300 ml BOD bottle, fill up with dilution water;20 ml sample in 300 ml BOD bottle, fill up with dilution water 2. Take 300 ml sample in BOD bottle. Prepare two sets of this sample. Keep one set for DO analysis for day 0 (i.e., Sample0Day) and another sample in BOD incubator for 5 days at 20 C (Sample5Day). 3. Measure DO in different samples at t=0. 4. Incubate samples in 20 o C for 5 days. 5. Come back in the lab after 5 days and record dissolved oxygen. 6. Record data in following manner. Bottle no. Wastewater sample (ml) Initial DO (mg/l) (DO 0 ) 1 2 3 4 Calculate 5-day BOD value of the sample at 20 C: t-day BOD= [DO t -DO 0 ]/(P) (1) where P= Dilution factor = 300mL/(sample volume in ml) DO at 5-day (ml) (DO 5 ) Questions to Answer: 1. If 5-day BOD at 20 C=150mg/L (k=0.23/day), calculate 5-day BOD at 15 C and 22 C? Use following dependence of (k) with temperature: k T =k 20 {θ} (T-20)

Page 3 Reference: AWWA, WEF, APHA, 1998, Standard Methods for the Examination of Water and Wastewater (Method: 4500-O. C. Azide Modification) AWWA, WEF, APHA, 1998, Standard Methods for the Examination of Water and Wastewater (Method: 5210B,5-day BOD) Sawyer, C.N., McCarty, P.L., and Parkin, G.F. 2000. Chemistry for Environmental Engineering 4 th Edition. Tata McGraw-Hill Publishing Company Limited. ++++++++++++Additional questions (not to submit)+++++++++++++ Q: Calculate oxygen consumption rates of samples with given data and comment on biodegradability time(d) sample 1(BOD(mg/L) at 20degC) 1 5 10 4 10 20 5 70 40 8 90 50 30 120 80 sample 2(BOD(mg/L) at 20degC)

Page 4 7B:Chemical Oxygen Demand (COD) (closed reflux method) Objective 2: To determine COD value for determining organic strength of solution (Closed Reflux Method) Background: Chemical oxygen demand (COD) is termed as the amount of a specific oxidizing agent that reacts with sample under controlled conditions and it is expressed as oxygen equivalence. This parameter indicates the extent of organic matter contamination of water and is always higher than the biochemical oxygen demand (BOD). It is used to indicate organic matter contamination and it helps in knowing overall organic load to the receiving body. Selection of Method There are two methods for COD determination. The first method: open reflux method is suitable for a wide range of wastes where large volume of sample is required (for samples with COD= 50 mg O 2 /L). In the second method: closed reflux methods, small quantities of metallic salt reagents are required and small quantities of hazardous waste is produced (for samples with COD= 5 to 50 mg O 2 /L). In the closed reflux method, ampules and culture tubes with premeasured reagents are used and then samples is placed in the tube and COD is determined. In this experiment, closed reflux method is used and samples with COD < 50 mg O 2 /L are tested. Reaction with dichromate solution of sample: Potassium dichromate is a strong oxidizing agent and it can be used to prepare solution of exact normality. C n H a O b N c +d Cr 2 O 7 2- + (8d+c) H + => nco 2 +[(a+8d-3c)/2]h 2 O+c NH 4 + +2dCr 3+ (1) Here d=(2n/3)+(a/6)-(b/3)-(c/2) During experiment, excess dichromate concentration is determined by titrating it with ferrous ammonium sulfate (FAS). The reaction is given by: 6Fe 2+ Cr 2 O 7 2- + 14 H + => 6Fe 3+ + 2Cr 3+ +7H 2 O (2) Here d=(2n/3)+(a/6)-(b/3)-(c/2) Ferroin (ferrous 1,10-phenanthroline sulfate): It is used to indicate change in oxidation-reduction potential of the solution and it indicates the condition when all dichromate has been reduced by ferrous ion. It gives a very sharp brown color change which can be seen in spite of blue color generated by the Cr 3+ ions formed on reduction of the dichromate. Procedure: Apparatus: Digestion vessels; block heater; microburet; ampule sealer. Borosilicate culture tubes (16mm*100 mm or 20 mm*150mm) with TFE lined-screw caps are used. The block heater is required to operate at 150±2 C with holes to accommodated digestion vessels. Do not use an oven because of the possibility of leaking samples generating corrosive and explosive atmosphere. Reagents:

Page 5 a. Standard potassium dichromate digestion solution, 0.01667M: Add to about 500 ml distilled water 4.903 g K 2 Cr 2 O 7, primary standard grade, previously dried at 150 C for 2 h, 167 ml conc. H 2 SO 4, and 33.3 g HgSO 4. Dissolve, cool to room temperature, and dilute to 1000 ml. b. Sulfuric acid reagent: c. Ferroin indicator solution: Dilute it by a factor of 5 as required. This indicator is used to indicate change in oxidation-reduction potential of the solution. d. Standard ferrous ammonium sulfate titrant (FAS), approximately 0.10M: Dissolve 39.2 g Fe(NH 4 ) 2 (SO 4 ) 2.6H 2 O in distilled water. Add 20 ml conc H2SO4, cool, and dilute to 1000 ml. Standardize solution daily against standard K2Cr2O7 digestion solution as follows: Pipet 5.00 ml digestion solution into a small beaker. Add 10 ml reagent water to substitute for sample. Cool to room temperature. Add 1 to 2 drops diluted ferroin indicator and titrate with FAS titrant. Molarity of FAS solution = [V K2Cr2O7 0.1] / (V FAS ) (3) Where: V K2Cr2O7 = volume of K2Cr2O7 (ml); V FAS = volume of FAS (ml) e. Sulfamic acid: f. Potassium hydrogen phthalate standard: Steps: 1. Wash culture tubes and caps with 20% H2SO4 before using to prevent contamination. 2. Place sample in culture tube or ampule and add digestion solution. Carefully run sulfuric acid reagent down inside of vessel so an acid layer is formed under the sample-digestion solution layer and tightly cap tubes or seal ampules, and invert each several times to mix completely. 3. Place tubes or ampules in block digester preheated to 150 C and reflux for 2 h behind a protective shield. CAUTION: These sealed vessels may be under pressure from gases generated during digestion. Wear face and hand protection when handling and dangerous pressures will be generated at 150 C. 4. Cool to room temperature and place vessels in test tube rack. Some mercuric sulfate may precipitate out but this will not affect the analysis. 5. Remove culture tube caps and add small TFE-covered magnetic stirring bar. If ampules are used, transfer contents to a larger container for titrating. 6. Add 0.05 to 0.10 ml (1 to 2 drops) ferroin indicator and stir rapidly on magnetic stirrer while titrating with standardized 0.10M FAS. The end point is a sharp color change from blue-green to reddish brown, although the bluegreen may reappear within minutes. In the same manner reflux and titrate a blank containing the reagents and a volume of distilled water equal to that of the sample. 7. COD is given by COD as mg/l O 2 /L = [(A-B) M 8000) / (V sample ) (4) Where: A = volume of FAS used for blank (ml); B= volume of FAS used for sample (ml); M=molarity of FAS; 8000= miliquivalent weight of oxygen 1000 ml/l Analyze samples in duplicates because of small sample size. Questions to Answer: 1. Why do the COD analysis and BOD analysis give different results for the same waste?

Page 6 2. What could be inferred from the following samples concerning the relative ease of biodegradability: Sample A (5-d BOD/COD=24/30) and Sample B (5-d BOD/COD=10/50)? Reference: AWWA, WEF, APHA, 1998, Standard Methods for the Examination of Water and Wastewater (Methods: 5220 C. Closed Reflux Titrimetric Method) Sawyer, C.N., McCarty, P.L., and Parkin, G.F. 2000. Chemistry for Environmental Engineering 4 th Edition. Tata McGraw-Hill Publishing Company Limited.