Energy Recovery Process Cooling Example. Presentation - Overview. Air Change Australia Pty Ltd. Air Change Energy Recovery Range

Similar documents
Cooling coil optimisation in hot and humid climates for IAQ and energy considerations

Next Generation: High Efficiency Energy Recovery Ventilator (ERV) 11/14/11 Dais Analytic Corporation

Eurovent Association Eurovent Certification Activities related to ENERGY EFFICIENCY

Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambéry, France, August 26-28

IN THIS ISSUE INTRODUCTION BACKGROUND. March 2018 High Humidity in Winter: Analysis for Multi-Family Passive House Projects

Grunenwald Science and Technology Building

Georgetown University New Science Center

Fresh air pre-cooling and energy recovery by using indirect evaporative cooling in hot and humid region a case study in Hong Kong

Modular Active Chilled Beams

Project Proposal Proposal for Investigation of Alternative Systems

How to maximise energy efficiency and cost effectiveness of different type heat pump projects three case studies

2-Pipe fan coil terminal units were selected as the parallel system to handle the remaining sensible cooling load.

What simulation can tell us about building tuning

Energy Recovery Ventilation & ERV Basics The New Custom Express Tool

Mechanical Depth. Redesign and Analysis

A Paradigm Shift in ERV Technology. Paul Ehrlich, PE President Building Intelligence Group PLLC

FLEXY EC HIGH EFFICIENCY ROOFTOP kw AIR COOLED COOLING ONLY/HEAT PUMP/ GAS/ DUAL FUEL

AN INNOVATIVE DEDICATED OUTDOOR AIR APPLICATION FOR A GOVERNMENT OFFICE TOWER. MICHAEL HALLENBECK, PE, CEM Southland Industries

Rooftops High performance, proven reliability and easy installation

Air-Water Systems. Chilled Ceilings and Beams TROX USA. Principle of Operation. Radiant Effect on Occupants. Early 1980 s. Chilled Ceiling Panels

275 GEORGE STREET, BRISBANE CASE STUDY. Andrew Gentner Norman Disney & Young, Spring Hill QLD, Australia

THE USE OF HEAT RECOVERY DEVICES FOR REDUCING ENERGY CONSUMPTION OF TREATING VENTILATION AIR IN A TROPICAL OPERATING THEATRE

SHIYUN CHEN ADVISOR: DR. BAHNFLETH. 1 Executive Summary Building Summary 3. 3 Existing Mechanical System. 4

Energy Efficiency in Building Active Design Part II

Technical Report Three Mechanical Systems Existing Conditions Evaluation

APPLICATIONS Air-to-Air Energy Recovery

HVAC SYSTEM CONFIGURATIONS, AN ENERGY ASPECT

Ceiling Radiant Cooling Panels

Demonstration of modeling of radiant cooling system in design builder. Prashant Bhanware & Bharath Reddy

Air Conditioning & Heating. Adia-Denco» Indirect Evaporative Cooling

EMD SERONO RESEARCH CENTER EXISTING

BUILDING PERFORMANCE IMPROVEMENTS FROM NCC2019

Depth: Mechanical Redesign

Gas Turbine Inlet Air Cooling System

Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs. Valent is a business of Unison Comfort Technologies.

201 Charlotte Street, Brisbane, Queensland

TECHNICAL REPORT 3 JESSUP, MARYLAND. Mechanical System Existing Conditions Evaluation BY CHRISTOPHER LORENZ MECHANICAL, FOR DR. BAHNFLETH SUBMITTED

Hourly Analysis Program v.4.1 Page 1 of 1

The Case for Energy Recovery in addressing Commercial Building Indoor Air Quality

Ceiling Radiant Cooling Panels

Thesis Proposal. Clemson University Advanced Material Research Laboratory Anderson, SC. David Anderson Mechanical Option. Photo by Fred Martin

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1

Hourly Analysis Program v.4.1 Page 1 of 1

Trane Engineering News Multi-pipe unit for heating and cooling buildings

Application of Advanced Energy Technologies

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

ASHRAE 90.2 Kuwait What Can be Learned From It?

SURNA Grow Facility: Systems Comparison - IEA

Hourly Analysis Program v.4.1 Page 1 of 1

Does NZEB pose a conflict to Good Indoor Air Quality? REHVA summit November 2017

Performance evaluation of a small-scale polygeneration plant including a desiccant cooling system and an innovative natural gas ICE

EQ ENERGY SAVING PRODUCTS

Using System Curves to Avoid Problems in VAV Systems

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE

FUNDAMENTALS OF CHILLED BEAMS ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

YKN2open A R C 032 A B

Eurovent certification programmes for HVAC products with verified performances

Content. State of the Art in Solar Cooling. Solar cooling technology developments. Market developments & barriers

Chilled Water Plant Redesign

Voyager kw rooftop units Plug and Play comfort in commercial applications

Year-round Energy Saving Potential for a Stratum Ventilated Subtropical Office. C.K. Lee Zhang Lin K.F. Fong

A Primer on Recovery Efficiency Ratio

ASHRAE s LowDown Showdown

Proposed Fan System Measures for NCC Section J, 2019

SPEAKMAN HYBRID ROOFTOP UNIT PERFORMANCE: WESTERN COOLING CHALLENGE LABORATORY TEST RESULTS

Central Chiller Plants

Great Ocean Rd Ice Creamery

Mission Critical Commissioning for Healthcare Facilities

The Milton S. Hershey Medical Center Academic Support Building. AE Senior Thesis Kari Anne Donovan Mechanical Option

Viridis Australasia?? 1

Interdisciplinary Science and Engineering Building

Free Cooling Technology

Air Cooled Packaged Air Conditioning

Interdisciplinary Science and Engineering Building

UNDERFLOOR AIR DISTRIBUTION INTEGRATED WITH AN INDIRECT AND DIRECT EVAPORATIVE COOLING ASSISTED 100% OUTDOOR AIR SYSTEM

To efficiency and beyond

Chilled Beams. The new system of choice?

Walter Reed National Military Medical Center Bethesda, MD

Acknowledgements 4. Executive Summary 5

ENERGY RECOVERY IN MINNESOTA:

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

How to benefit from the Eurovent- Certification database and to retrieve past equipment data in the audit process

Mechanical Systems Redesign Proposal. Thesis Proposal. Morton Hospital Expansion

Air distribution and temperature control in classrooms

Labelling and certification of HVAC products

Deep Energy Retrofit Modeling and Cost Effectiveness Study: A Technical Policy Brief. January 2013

Design and development of a residential gas-fired heat pump

Reducing Hospital Energy Use and Maintaining Savings. Glen Anderson, PE

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.40

Hollingsworth & Vose

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

Designing for 100% OA In Hospitals. Southland Industries

Appendix E-1f: Small Building Methodology for Pre-SB2030 Projects

Implementing Demand Controlled Ventilation to Meet ASHRAE Standard By KlasC. Haglid, P.E., R.A., CEM

Operating Engineers Seminar Bob Ford Jeff Volovsek

2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment

Level 1 Modules tdp-101 hvac industry overview tdp-103 concepts of air conditioning tdp-102 abcs of comfort

Halton Chilled beams Janne Summanen Halton Oy

Transcription:

2 Presentation - Overview Energy Recovery Range + Designing Plant Rooms for Energy Efficiency The Company and the Technology Energy Recovery Product Range Product Range Pre-conditioners vs ERV-AHU s Energy Recovery Alternatives Design Considerations AHU Plant Space Comparison ERV-IC and ACDHUM Application 324 Queen Street Case Study Closing Comments and Questions Australia Pty Ltd 3 Energy Recovery Process Cooling Example 4 Registered in October 2000 began manufacturing HVAC systems with Integrated plate Heat Exchangers Up to 2005 made steady inroads into the market boosted by Pubs and Clubs in NSW which required 100% Fresh Air AC Units 2005- Present continued strong growth spurred on by the drive for energy efficiency (BCA, NABERS, GreenStar) increased cost of electricity and Awareness regarding the benefits of better indoor air quality Hot Exhaust Air to Atmosphere Pre conditioned Supply Air Hot Humid Outside Air 32 o DB/25 o WB Cool Dry Return Air 24 o DB/17 o WB 26 o DB/19.3 o WB

5 6 Counter-flow Heat Exchanger Product Range Energy Recovery Ventilators Energy Recovery AHU s Packaged Conditioners Dehumidification Units Sensible Plate Type 80% nominal efficiency Mylar film Enthalpy Plate Type 75% nominal efficiency Cellulose media 7 8 Pre-conditioners vs ERV-AHU s Energy Recovery Alternatives Typical Queensland 20th Century Outside Air Pre-conditioner includes 8 row coil with face velocity of less than 1.8 m/s Through the use of an Enthalpy Heat Exchanger we can precondition outside air down to approx 26CDB/19CWB generally only requires a 4 row coil Enthalpy Wheels considerations Efficiency on par initially deteriorating efficiency over life of unit due to Hysteresis Moving parts add maintenance cost and reliability concerns Lower face velocity to achieve high efficiency results in larger unit size Common air path higher cross contamination Where return air can t be obtained utilize an Dehumidification unit as an outside air pre-conditioner Cross Flow Heat Exchangers imported from Asia or Europe Typically 45-65% efficiency Be mindful of low efficiency can turn a 2 year payback into a 4-5 year payback

Heat Exchanger Life, Reliability and Performance Project Services Performance Certification The pressure drop and efficiencies shall be certified against either Eurovent or ARI standards at both summer and winter rating conditions. The operating temperature range shall be from -40 to + 90 degc Enthalpy and Sensible Only Heat Exchangers tested in accordance with ASHRAE 84-1991 No Moving Parts requires no maintenance with adequate filtration Accelerated life cycle tests have shown no loss in efficiency over a test period equivalent to 15 years under normal operating conditions 9 BCA Section J, NABERS, Greenstar, MEPS Greenstar Energy ENE-1 and ENE-5 Greenhouse Gas Emission and Peak Demand Reduction IEQ-1 Outside Air Ventilation Rates up to 3 points available for improvements over AS1668.2-1991 50%, 100% and 150% BCA Section J5 and MEPS Economy Cycle > 50kWr Climate Zone 2 and 3 Table J5.2 for fan power limits (W/m2) excludes power for an energy reclaiming system Systems which utilize outside air pre-conditioning will generally require a lower supply air quantity to meet sensible load Packaged units must have an EER greater than 2.7 (greater than 65 kwr) with Concession for Heat Exchanger EER s for RTP s are between 4.9-5.2 10 AS1668.2-1991 Considerations Outside Air rates generally between 7.5-20 l/s/personas1668.2-1991 Considerations 11 12 In Ceiling ERV s In ceiling ERV s have been used extensively for office fit outs particularly to serve meeting rooms Be careful when nominating a unit manufacturer as performance varies significantly significantly ACDHUM Dehumidification Units 28.2 o C Manufacturer ERV-IC 400 Competitor 1 Competitor 2 Competitor 3 24 o C 50% RH 12.9 o C 32 o C 57% RH (17.2 g/kg) Nominal Airflow 400 417 416 420 Total Efficiency Energy Recovered Brisbane 75% 73% 66% 50% 9.6 9 8.3 6.2 12.9 o C 90% RH 20.9 o C (15.5 g/kg) 12.9 o C Absorbed Fan Power 480 830 920 500 COP 20 10.8 9 12.4

ACDHUM - Applications 13 Pre-condition Outside Air to Room Conditions (18-24 degrees) Commercial Buildings - connected to tenant outside air dropper DOAS for Hospitals, Apartment Buildings etc Humidity Control System for Supermarkets and Laboratories Operate in Recirculation mode after hours to control humidity within space AHU Plant Space Comparison Horizontal FCU Enthalpy Wheel AHU Plant Space 2000 lpsrules 2000 of Thumb lps ERV-AHU 2000 lps 14 Horizontal Enthalpy FCU Wheel AHU ERV-AHU 4000 lps 4000 lps 4000 lps Length 2100 2700 2000 2400 3000 2000 Width 2600 3300 3200 3300 4000 4100 Height 1100 2100 1800 1365 2700 1800 Footprint 5.5 8.9 6.4 7.9 12 8.2 (m 2 ) Footprint N/A 60% 15% N/A 50% 5% Premium All sizes exclude filter plenums/mixing boxes 324 Queen Street Case Study 15 Airflow Schematic 16 27 Storey Commercial Tower in the CBD In mid 2010 - Cardno ITC were commissioned to undertake the Mechanical Design for the Energy Efficiency Upgrade Existing Outside Air System consisted of 4 off Muller McQuay CHW AHU s Proposal.. Replace units with GB-AHU s

17 18 324 Queen Street Comparison 19 20 324 Queen Street Comparison Existing AHU s Muller McQuay Energy Recovery AHU s Savings Peak Load Airflow 8200 8200 - Total Capacity (kwr) 434 249 185 Chilled Water Flow Rate (lps) 17.3 10 7.3 Water Pressure Drop (kpa) 148 36 112 Savings Reduction in Chiller Power Consumption - lower CHW flow rates Reduced Chilled Water Pump Power Reduced Peak Demand PLANT SPACE Summary.. Rules of Thumb HX in South East Queensland Enthalpy Type HX approx 3 kw per 100 lps of Outside Air Sensible Type HX approx 1 kw per 100 lps of Outside Air There are no rules of thumb for how much more space is required to accommodate Energy Recovery Equipment we would encourage designers to get Involved at the Concept Stage to see what we can offer Payback Periods Typically 0-36 months Plate Type Heat Exchangers will generally require less space than an equivalent Enthalpy Wheel AHU (easier to replace) More often than not we can adapt our AHU range to meet your requirements including; Horizontal, Vertical or Side discharge Fan upgrades for ESP s in excess of 1000 Pa Chilled and Hot Water Coils to Spec CV, VAV and MTZ systems