Showcase Your Space. Not Your Access Panel. Product Features. Shop online at or call

Similar documents
SECTION GLASS FIBER REINFORCED GYPSUM FABRICATIONS

PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) REV: 4/11

09/07/07 GLASSFIBER REINFORCED GYPSUM (GRG) C. S. I Spec Master Spec Page 1

First Class Building Products, Inc.

Foil Back Gypsum Board

High Flex Gypsum Board

G.R.G. (GLASSFIBRE REINFORCED GYPSUM) (For Interior Systems)

SECTION GYPSUM BOARD ASSEMBLIES

Gold Bond BRAND Gypsum Sheathing

High Strength LITE Gypsum Board

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

A. Section Wood, Plastics and Composites.

SECTION ACOUSTICAL PLASTER CEILINGS

Phenolic Exterior Wall Cladding

SECTION ACOUSTICAL PLASTER CEILINGS

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

SECTION ACOUSTICAL PLASTER CEILINGS

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

Decorative Fiberglass Reinforced Wall Panels

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

Gold Bond BRAND Kal-Kore Plaster Base

Use it for interior wall and ceiling applications and in areas with limited water exposure.

SECTION GYPSUM BOARD

Section SoundPly RF M25 Acoustic Wall Panels

Nudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

SECTION SHOWER AND DRESSING COMPARTMENTS

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

SECTION COLD-FORMED METAL FRAMING

***************************************************************** ** NOTE TO SPECIFIER **

SECTION GYPSUM BOARD ASSEMBLIES

Section SoundPly LR M25 Acoustic Ceiling Panels

A. Stonewood: Solid phenolic panels for interior wall cladding of commercial and institutional buildings.

SECTION COLD-FORMED METAL FRAMING

Framed Decorative Panel Systems

First Class Building Products, Inc.

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

Series - 1

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

DIVISION VIII - DOORS AND WINDOWS

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

Substitution Request

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION IMPACT RESISTANT WALL PROTECTION

Interior Extreme AR. Gypsum Panels. Gold Bond BRAND

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

HIR 1 ACOUSTICAL, IMPACT RESISTANT, TACKABLE WALL PANEL SPECIFICATION

XP Gypsum Board Regular, Fire-Shield Type X and Fire-Shield Type C

SECTION GYPSUM BOARD ASSEMBLIES

COMPOSITESIDING

SECTION INTUMESCENT MASTIC FIREPROOFING

EXTERIOR PLANK SERIES SPECIFICATION DATA

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

SECTION ACCORDION FOLDING PARTITIONS

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD ASSEMBLIES

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

SECTION (09800) - Suspended Acoustic Baffles. This Section is based on TECHLITE Accent Linear Ceiling Baffles.

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Marlite Guide Specification 2/24/2017 Surface Systems - MAP375 System SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION WALL AND DOOR PROTECTION

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION MULTICOLOR INTERIOR FINISHING

SECTION STRUCTURAL INSULATED PANELS

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Submittal Transmittal

SECTION ACOUSTICAL WALL TREATMENT (CEMENTITIOUS WOOD FIBER WALL PANELS)

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

Section GYPSUM DRYWALL

Key Features. Glass Locker Series GL5000. ¼ inch tempered glass doors with soft closing hinges. Back-painted glass can be matched to any Pantone color

SECTION GYPSUM BOARD

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

SECTION DOOR AND WALL PROTECTION

SECTION LINEAR WOOD CEILINGS

Transcription:

Showcase Your Space Not Your Access Panel Stealth Access Panels are glass fiber reinforced gypsum ceiling access panels that are aesthetically pleasing because they are designed to blend seamlessly into a drywall ceiling. Stealth Panels are available in commercial, residential, interior and exterior models in a wide range of stock and custom sizes. Residential models incorporate an energysaving gasket seal that keeps attic temperatures from infiltrating the living space. Stealth Panels are perfect for jobs where access is required at regular intervals. The panels consist of a surround frame with pre-drilled/spotted fastener holes and a drop-in door. They can be used in both new and retrofit construction projects. If you think Stealth Panels could benefit your next project, contact us today for pricing. Product Features Tapered edge for tape joint Easily textured Lightweight Smooth round edge Single trade installation Blends into surrounding drywall No shrinkage No cracking Perfect for retrofit applications Reduce labor costs Shop online at www.wind-lock.com or call 1.800.872.5625

Installing Stealth Panels 1. Frame the opening. 2. Mount Stealth surround with drywall screws. 3. Install drywall and place access panel in opening. 4. Tape, apply drywall compound, finish and paint. Shop online at www.wind-lock.com or call 1.800.872.5625

Stealth Panels Technical Data Shell Thickness 1/8" to 3/16" Fastener Test Pull Out (wood stud) Fastener Test Pull Out (metal stud) 525 lb avg. 215 lb avg. Fastener Push Through Test 350 lb avg. Fuel Contribu on (ASTM E84-80) 0 Flame Spread (ASTM E84-80) 0 Smoke Index (ASTM E84-80) 5 Combus on (ASTM E84-80) Non-combus ble C lass A Non-Rated CSI Code CSI #08310 Stealth UL Fire Testing Characteristics Test Purpose Flame Spread Smoke Developed Result ASTM E-84 Surface Burning <25 <450 Passed Characteristics Actual Results: 0 flame spread. 0 smoke (developed) index. 0 fuel contribution (the surface of the panel). Stealth GFRG access panels are NON- COMBUSTIBLE. They will not catch on fire, or contribute to a fire. Ordering Informa on Part Code Access Opening Rough Opening Commercial Access Panels TR-AP009 9" X 9" 15" X 15" TR-AP012 12" X 12" TR-AP016 16" X 16" TR-AP018 18" X 18" TR-AP024 24" X 24" Residen al Access Panels (with gasket) TR-APGR2230 22" X 30" TR-APGR3030 30" X 30" Specialty Round Panels TR-RAP012 12" diameter TR-RAP016 16" diameter TR-RAP018 18" diameter TR-RAP024 24" diameter Hinged Access Panels TR-HAP009 9" X 9" TR-HAP012 12" X 12" TR-HAP016 16" X 16" TR-HAP018 18" X 18" TR-HAP024 24" X 24" 18" X 18" 22" X 22" 24" X 24" 30" X 30" 24" X 36" 36" X 36" 18" X 18" 22" X 22" 24" X 24" 30" X 30" 15" X 15" 18" X 18" 22" X 22" 24" X 24" 30" X 30" Sold 2 per box. Custom sizes available. Call for more details. Shop online at www.wind-lock.com or call 1.800.872.5625

Specification for Glass Fiber Reinforced Gypsum (GFRG) STEALTH Access Panels For Interior Applications 1. General 1.1 Summary A. This section includes furnishing all materials, labor, equipment, and related services necessary to supply and install molded glass fiber reinforced gypsum (GRG) parts as indicated in the contract documents, and in compliance with applicable codes. 1.2 Related Sections A. Section 06 10 00 Rough Carpentry - for blocking, nailers, shims and carpentry supporting glass fiber reinforced gypsum fabrications. B. Section 09 22 00 Supports for Plaster and Gypsum Board - for support, blocking, and bracing supporting glass fiber reinforced gypsum fabrications. C. Section 09 90 00 Painting and Coating 1.3 References A. ASTM International (ASTM) 1. C1381 Standard Specification for Molded Glass Fiber Reinforced Gypsum Parts. 2. C1467 Standard Specification for the Installation of Molded Glass Fiber Reinforced Gypsum Parts. 3. C1355 Standard Specification of Glass Fiber Reinforced Gypsum Composites 4. C754 Specification for Installation of Steel Framing Members to Receive Screw- Attached Gypsum Panel Products. 5. C1007 Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories. 6. C840 Specification for Application and Finishing of Gypsum Board 1.4 Submittals A. Product Data: Submit product data sheets for each specified product, including dimensions, finishes, storage and handling requirements and recommendations and installation recommendations. B. Samples: 6 inches (150mm) square, representing actual product, color and patterns available upon request. C. Shop Drawings: Submit drawings for approval showing plans, sections, details, joint treatment, reinforcing, fastening devices and the relation of the GRG parts to the surrounding construction. 1.5 Quality Assurance A. GRG Parts and Installation to conform to ASTM Standards governing Molded Glass Fiber Reinforced Gypsum Parts, namely: C1355; C1381; and, C1467 including physical properties and tolerances. See 1.3 References. B. Manufacturer Qualifications: Manufacturer shall have a minimum of 5 years of experience having successfully supplied GRG parts for other projects similar in scope and complexity for the work of this Contract. C. Installer Qualifications: Installer shall have a minimum of 5 years of experience having successfully installed GRG parts for other projects similar in scope and complexity for the work of this Contract. D. The Alpha gypsum cement used to make the GRG parts is to be mined and processed in the USA with a purity of not less than 90% in accordance to ASTM C1355. Provide a Manufacturer s Certification of Raw Materials. E. Substrates to accept GRG parts shall be installed straight and true within 1/8 in. in 8 linear ft. (3mm in 2500mm) in accordance to ASTM C1467 and shall be free of obstructions and interference that prohibits the correct alignment and attachment of the GRG parts. F. The gypsum drywall contractor shall install and tape the work under this section and will be responsible for coordinating the installation with gypsum drywall work and other trades. 1.6 Delivery, Storage and Handling A. GRG parts shall be kept clean and dry and stored to prevent distortion, warping, and other physical damage in accordance with the manufacturer s recommendations. 1.7 Project Conditions A. Environmental Limitations: Do not deliver or install GRG parts until building is enclosed and weatherproof, wet work is complete, and the HVAC system maintains temperature and humidity at normal occupancy levels. B. Acclimatize GRG parts for a minimum of 48 hours to the ambient temperature and humidity levels of spaces in which they are to be installed. 2. Products. 2.1 Manufacturers Wind-lock 1055 Leiscz s Bridge Rd Leesport, PA 19533 800-872-5625 www.wind-lock.com 2.2 Substitutions A. Not permitted. B. Request for substitutions will be considered on accordance with provisions of Section 01600. 2.3 Glass Fiber Reinforced Gypsum (GRG) Parts A. Fabrications: Molded GRG parts made in accordance with samples, shop drawings and with ASTM C1381 Standard for Molded Glass Fiber Reinforced Gypsum Parts. B. Materials: Molded GRG parts to be made in accordance with ASTM C1355 Standard for Glass Fiber Reinforced Gypsum Composites. C. Embedment: GRG parts to have typical embedment and reinforcement of galvanized steel or wood, if required, for the purposes of suspension, attachment and stiffness. D. Molded GRG units to be ready for primer for typical flat paint finishes. E. GRG parts subject to critical lighting or scheduled to receive semi-gloss decoration shall be prepared as a Level 5 finish which may require skim coats, filling, and sanding to hide imperfections inherent in GRG, in accordance to ASTM Standards C840 and C1467. 2.4 Physical Properties A. Molded Glass Fiber Reinforced Gypsum Parts meet the following mechanical properties including those required in ASTM Standards C1381 & C1355: (1) Glass Content: not less than 5 percent by weight (2) Density: 103 to 112 pcf (3) Shell (Part) Thickness: not less than 3/16 (4) Control Thickness: not less than 5/16 (5) Dimensional: overall in all directions +/- 1/8 (6) Straightness: +/- 1/8 in 8 ft (7) Warpage/Bowing: +/- 1/16 per ft (8) Draft Angle: 3 degrees minimum on returns, setbacks, reveals and grooves (9) Flexural Yield Strength: not less than 1200 psi (ASTM C947) (10) Flexural Ultimate Strength: not less than 2500 psi (ASTM C947) (11) Impact Resistance: not less than 3 ft-lb (ASTM D256) (12) Hardness: not less than 50 Barcol (ASTM D2583) (13) Coefficient of Linear Thermal Expansion: not more than 11.1x10-6 in/in F (ASTM D696) (14) Humidified Deflection: not more than 1/8 (3 mm) (ASTM C473) (15) Flammability: Flame Spread & Smoke Development Index of 0 (ASTM E84) (16) Behavior at 750 C: Pass (ASTM E136) (17) Nail Pull Resistance: not less than 110 lbf (ASTM C473) 3. Execution 3.1 Examination A. Site Conditions: Verify the conditions for compliance with the requirements including environmental conditions, installation tolerances and other conditions affecting the installation and performance of GRG parts. Any unsatisfactory conditions to be corrected prior to installation. B. Field Dimensions: Field dimensions are to be verified including those not shown on the drawings. Any discrepancies are to be brought to the attention of the Architect with resolutions to the discrepancies to be mutually agreed upon by all parties involved. Details of any changes required must be incorporated into the manufacturer s shop drawings prior to commencing the manufacture of the GRG parts. 3.2 Preparation A. Substrate: Substrates to accept GRG parts, provided by others, shall be installed straight and true within 1/8 in. in 8 ft. (3mm in 2500mm) and shall be free of obstructions and interference that prohibits correct attachment of GRG parts. B. Metal framing members, provided by others, shall be of the proper size and design for the intended use and shall be sufficient to properly support the installed GRG parts. Metal framing members shall be installed in accordance with ASTM Standards C754 or C1007 as required. C. Ensure clean surfaces prior to installation. 3.3 Installation A. Comply with ASTM C1467 Standard for the Installation of Molded Glass Fiber Reinforced Gypsum Parts. B. It is the Installer s responsibility to verify scope and to order the correct quantities of parts (including a waste allowance). C. Supply and install all shims and brackets required for work in this section and to ensure a solid and secure installation of GRG parts. D. Position GRG parts carefully into place and align with adjacent parts and materials in accordance to the drawings. Attach GRG parts to substrates and framing with fastening devices as specified by the GRG manufacturer. Use concealed shims as required and countersink screws below the surrounding surface. E. Where GRG parts are suspended, use the suspension points indicated on the shop drawings as a minimum requirement and use additional support(s) if required. F. Install control joints between GRG parts as indicated and as required by the manufacturer. G. Use joint-treatment materials to finish GRG parts and assemblies to produce surfaces ready to receive primers and paint finishes as detailed. Note: Unfinished GRG parts may exhibit slight imperfections, normally hidden by a textured finished. To obtain satisfactory results with smooth finishes, filling and sanding will be required to hide imperfections inherent in GRG. 3.4 Protection A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before substantial completion.