Calculation of the Amount of Hydrogen Absorbed by Steel During the Mechanical Plating Operation

Similar documents
Kinetic Characteristics of Different Materials used for Bolting Applications

Corrosion Rate Measurement on C-Steel

Studies on Alloys and Composites that Undergo Anomalous Codeposition

Surface films formed during H 2 S corrosion of pipeline steels and the effect on hydrogen permeation

Ulf NürnbergerN. Contribution of the group Metallic

Automatic Control of Inhibitor Content in Cooling Water of Marine Engine

What happens if we connect Zn and Pt in HCl solution? Corrosion of platinum (Pt) in HCl. 1. If Zn and Pt are not connected


DIFFUSION CHARACTERISTICS OF HYDROGEN IN THE TRIP 800 C-Mn-Si-P STEEL. Jaroslav SOJKA, Petr ŠTĚPÁN, Petra VÁŇOVÁ

Short Communication The Effect of Temperature on the Hydrogen Permeation of Pipeline Steel in Wet Hydrogen Sulfide Environments

THE USE OF GALVANOSTATIC PULSE MEASUREMENTS TO DETERMINE CORROSION PARAMETERS Galvanostatic Pulse Measurement of Corrosion

Tutorial Corrosion II. Electrochemical characterization with EC-Lab techniques

2. Wet Corrosion: Characteristics, Prevention and Corrosion Rate

Potentiodynamic Scanning (PDS) of Stainless Steel Karen Louise de Sousa Pesse

low susceptibility to delayed fracture. High strength steels are known to be prone to delayed fracture.

Electrochemical response of permanent magnets in different solutions

IRON CARBONATE SCALE GROWTH AND THE EFFECT OF INHIBITION IN CO 2 CORROSION OF MILD STEEL

IN SITU MONITORING OF REINFORCEMENT CORROSION BY MEANS OF ELECTROCHEMICAL METHODS

الجامعة التكنولوجية قسم الهندسة الكيمياوية هندسة التاكل بشير ا حمد

BASICS OF CORROSION. Dr. Ramazan Kahraman

MEASURING THE EFFECTIVENESS OF MIGRATING CORROSION INHIBITORS (MCIs) BY ELECTROCHEMICAL TECHNIQUES

LASER SURFACE MELTING OF 17-4 PH PRECIPITATION-HARDENABLE STAINLESS STEEL Paper 1203

Introduction to Corrosion Science

Laboratory assessment of inhibition efficiency and mechanism of inhibitor blend (P22SU) on mild steel corrosion in high chloride containing water

Laboratory assessment of inhibition efficiency and mechanism of inhibitor blend (P22SU) on mild steel corrosion in high chloride containing water

CORROSION AND CORROSION CONTROL An Introduction to Corrosion Science and Engineering

Hydrogen Embrittlement of Subsea Structures. David Jones Minton, Treharne & Davies Ltd.

Experimental Studies to Determine Effects of Vapor Corrosion Inhibitors for Mitigating Corrosion in Casing. T5J 3N7 Canada ABSTRACT

THE ELECTROCHEMISTRY OF CORROSION Edited by Gareth Hinds from the original work of J G N Thomas

Available online at ScienceDirect. Procedia Materials Science 12 (2016 ) Diffusion of hydrogen in the TRIP 800 steel

Application Note CORR-4

Effect of Chromium on the Corrosion Behaviour of Low-Alloy Steels Containing Copper in FGD Environment

Preparation of Materials Lecture 6

COATING TECHNOLOGY OF HIGH STRENGTH STEELS WITHOUT HYDROGEN EMBRITTLEMENT

HYDROGEN DIFFUSION IN THE TRIP 800 STEEL WITH HIGHER PHOSPHORUS CONTENT EFFECT OF DEFORMATION

Guideline for Prevention of Damage in Water Heating Installations

Hydrogen Entry and its Effect on Delayed Fracture Susceptibility of High Strength Steel Bolts under Atmospheric Corrosion

A STUDY OF PROTECTIVE IRON CARBONATE SCALE FORMATION IN CO 2 CORROSION

Technical Reference on Hydrogen Compatibility of Materials

Evaluation of Corrosion Inhibitors for Cooling Water by Physico-Chemical Methods

MEASUREMENT OF STEEL CORROSION IN CONCRETE

Studies on electrodeposited Zn-Fe alloy coating on mild steel and its characterization

SERBIATRIB th International Conference on Tribology. Kragujevac, Serbia, May 2011

Corrosion Inhibitors for Protection of Galvanized Steel in Aqueous Solutions

CHAPTER 2 CORROSION MONITORING TECHNIQUES

CORROSION BEHAVIOR OF TITANIUM METAL IN PRESENCE OF INHIBITED SULFURIC ACID AT 50 o C 1

Module-13. Corrosion and Degradation of materials

Savannah River Site Tank Cleaning: Corrosion Rate for One Versus Eight percent Oxalic acid Solution

Paper No. CORROSION MODELING OF CO 2 CORROSION OF MILD STEEL AT HIGH PRESSURES OF CO 2 AND IN THE PRESENCE OF ACETIC ACID

Chapter 7a- Interpreting Polarization Curves

THE RELATIONSHIP BETWEEN SURFACE TREATMENTS AND CORROSION RESISTANCE OF HOT-DIP GALVANIZED STEEL. Amirreza Bakhtiari

Correlation between Neutral Salt Spray (NSS) Test and Potentiostat Dynamic Test for Corrosion on Zinc Plated Steel

Laboratory Experiments in Corrosion Engineering II

The Inhibitive Action of Tolyl-3,3 Dimethyl Thiourea on the Corrosion of Mild Steel in Brine Water

Effect Of Sintering Temperature, Heating Mode And Graphite Addition On The Corrosion Response Of Austenitic And Ferritic Stainless Steels

CHAPTER 2 MATERIALS AND METHODS

Significance and influence of the ambient temperature as a rate factor of steel reinforcement corrosion

A SIMPLIFIED METHOD TO ESTIMATE CORROSION RATES A NEW APPROACH BASED ON INVESTIGATIONS OF MACROCELLS Method to estimate corrosion rates

Technical Seminar for Cathodic Protection to GOGC Design Unit Specialists. Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA

Ginger extract as green corrosion inhibitor of mild steel in hydrochloric acid solution

Probabilistic Estimation of Corrosion Propagation Period for Prestressed Concrete Structures Exposed to Chlorides

M.N.Singh, D.K.Basu, A.K.Bhattmishra and S. K.Narang CORROSION RESISTANT ELECRODEPOSITED ZINC COATING FROM ZINC DROSS

Hydrogen Generation During the Corrosion of Carbon Steel in Oxalic Acid (U) B. J. Wiersma WSRC-TR (U)

DURABILITY of CONCRETE STRUCTURES

The ATI 17-4 precipitation hardening stainless steel (S17400) is covered by the following wrought product specifications.

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Inhibition of corrosion of copper by 2,5-dimercapto-1,3,4-thiadiazole in 3.5% NaCl solution

Batteries. Self contained electrochemical cell. Dry Cell (Flashlight Battery) ! Primary batteries (not rechargeable)

Polarization Functions of Pb-Sn-Cd Alloys Treated with Sulfuric Acid

COMPARATIVE STUDY ON THE CORROSION RESISTANCE OF Zn- 0.2 Pb AND Zn-0.5 Sb GALVANIZED COATINGS. A. Bakhtiari 1, H.R. Asgari 2.

Stable Charging Conditions for Low Hydrogen Concentrations in Steels

Electrochemical investigation of green film-forming corrosion inhibitors

SIGNIFICANCE OF HYDROGEN EVOLUTION IN CATHODIC PROTECTION OF STEEL IN SEAWATER

Corrosion. Lab. of Energy Conversion & Storage Materials. Produced by K. B. Kim

EROSION-CORROSION IN DISTURBED LIQUID/PARTICLE FLOW. A thesis presented to. the faculty of

Corrosion Behavior of Tin-Plated Carbon Steel and Aluminum in NaCl Solutions Using Electrochemical Impedance Spectroscopy

Environmental Degradation Fundamentals

Hydrogen-assisted stress corrosion cracking of high strength steel

EMA4303/5305 Electrochemical Engineering Lecture 05 Applications (1)

Dunarea de Jos University of Galati, 47 Domneasca Street, Galati, ROMANIA,

Chapter 16 Corrosion and Degradation of Materials

ROLES OF PASSIVATION AND GALVANIC EFFECTS IN LOCALIZED CO 2 CORROSION OF MILD STEEL

Corrosion Behaviour of 18%Ni M250 Grade Maraging Steel under Welded Condition in Hydrochloric Acid Medium

Corrosion in Reinforced Concrete

Corrosion inhibition of aluminum and aluminum silicon alloys in sodium hydroxide solutions by methyl cellulose

ELECTROCHEMICAL BEHAVIOUR OF ENVIRONMENTALLY- FRIENDLY INHIBITOR OF ALOE SECUNDIFLORA EXTRACT IN CORROSION CONTROL OF CARBON STEEL IN SOFT WATER MEDIA

Assignments. 1. Prepare Galvanic series for metals and alloys in flowing sea water. Compare this with the series available for stagnant sea water.

Conditions Under Which Cracks Occur in Modified 13% Chromium Steel in Wet Hydrogen Sulfide Environments

EFFECT OF CHLORIDE CONCENTRATION IN SOIL ON REINFORCEMENT CORROSION

Electrodeposition of nickel plates on copper substrates using PC y PRC

Effect of degassing electrolyte on polarisation curve shape with the aim to apply knowledge to electrochemical machining

A Novel Method to Mitigate the Top of the Line Corrosion in Wet Gas Pipelines by Corrosion Inhibitor within a Foam Matrix

Arch. Metall. Mater., Vol. 61 (2016), No 1, p

INFLUENCE OF WATER REPELLENT TREATMENT ON CORROSION OF STEEL IN CONCRETE

UNIT-I ELECTROCHEMISTRY PART-A

Effect of Condensation Product of Thiosemicarbazide and Phenyl Isothiocynate on Corrosion of Mild Steel in Sulphuric Acid Medium

Inhibiting Effect of Nicotinic Acid Hydrazide on Corrosion of Aluminum and Mild Steel in Acidic Medium

Jin Huang, Bruce Brown, Yoon-Seok Choi and Srdjan Nešić

Characteristic and efficiency of PEM fuel cell and PEM electrolyser

Transcription:

Calculation of the Amount of Hydrogen Absorbed by Steel During the Mechanical Plating Operation Experimental The polarisation resistance values obtained by Electrochemical Impedance Spectroscopy (EIS) in the initial report (mentioned above) were used to calculate the equivalent current density for hydrogen discharge. The average value of 1677 Ω/cm 2 was used for Macuguard SA containing inhibitor and 230 Ω/cm 2 was used for the uninhibited acid. In order to convert these values to current densities, a form of the Stern-Geary equation was used. The cathodic and anodic Tafel constants were determined by carrying out potentiodynamic scans on a 5% solution of the Macuguard with and without inhibitor using an EG&G potentiostat in conjunction with a silver/silver chloride reference electrode. The results of these scans are shown in figures 1 and 2. A Tafel fit was performed using CorrWare to calculate the values of β a and β c. Results and Discussion 1. Calculation The potentiodynamic scans are shown in figure 1 (anodic branch) and 2 (cathodic branch). The effect of the inhibitors in the formulation can clearly be seen. Because the scale of the potentiodynamic scans is logarithmic, the difference between the uninhibited and inhibited values is almost an order of magnitude. The anodic and cathodic Tafel constants obtained from the data fitting and the resultant equivalent corrosion current densities are shown in table 1. The anodic reaction is as follows: Fe Fe 2+ + 2e - The cathodic reaction is as follows: 2H + + 2e - H 2 The cathodic reaction is written in the form of hydrogen liberation but it must be appreciated that absorbed atomic hydrogen could also be a product. However, this does not change the overall mass balance. The rate of dissolution of iron and production of hydrogen can be calculated by applying

Faraday's law to the corrosion current density. The corrosion current density can be calculated from the following equation: i corr = B/R p Where B = (β a β c )/2.3(β a + β c ) Figure 1 Potentiodynamic Scan of Anodic Branch 0 S t d M a c u g u a r d S A a n o d i c. c o r S t d M a c u g u a r d S A n o i n h i b a n o d i c. c o r - 0. 1 E ( V o l t s ) - 0. 2-0. 3-0. 4-0. 5 1 0-7 1 0-6 1 0-5 1 0-4 1 0-3 1 0-2 1 0-1 1 0 0 I ( A m p s / c m 2 ) Figure 2 Potentiodynamic scan of Cathodic Branch - 0. 2 5 S t d M a c u g u a r d S A. c o r S t d M a c u g u a r d S A n o i n h i b c a t h. c o r - 0. 5 0 E ( V o l t s ) - 0. 7 5-1. 0 0-1. 2 5 1 0-7 1 0-6 1 0-5 1 0-4 1 0-3 1 0-2 1 0-1 1 0 0 I ( A m p s / c m 2 )

Table 1 Tafel Coefficients and Corrosion Current Densities Type of Solution β a (mv) β c (mv) B (mv) R p (Ω/cm 2 ) i corr (μa/cm 2 ) No Inhibitor 36.5 60.12 9.88 230 43 With Inhibitor 39.5 154.17 13.67 1677 8.1 Having calculated the corrosion current density, we now know the rate at which hydrogen is produced during the mechanical processing operation. If we assume a time of 30 minutes during which the Macuguard solution is in contact with the steel (this is longer than usual and also the 5% concentration that we tested the solution at is also somewhat more concentrated than would be used in practice), then we can calculate the total amount of hydrogen generated from the number of coulombs utilised in the corrosion reaction as follows: Uninhibited acid: Number of Coulombs = 4.3 x 10-5 x 1800 = 0.0774 C Inhibited acid: Number of Coulombs = 8.1 x 10-6 x 1800 = 0.0146 C We can now calculate the amount of atomic hydrogen generated during the mechanical plating operation (in moles) by dividing the number of coulombs used to generate hydrogen by the Faraday constant (96500 C/equiv): Moles of Hydrogen generated per square centimetre: Uninhibited acid: Moles of atomic hydrogen/cm 2 = 0.0774/96500 = 8.02 x 10-7 Inhibited acid: Moles of atomic hydrogen/cm 2 = 0.01458/96500 = 1.51 x 10-7 If we assume that all of the hydrogen generated at the surface is absorbed into the substrate and none leaves as hydrogen gas (again a worst case scenario), and we further assume that the hydrogen diffuses to a depth of 1mm and no further (also a worst case scenario, in practice diffusion of hydrogen would continue), then we can calculate the maximum hydrogen concentration within that volume of steel. Lovicu et al (1) determined the diffusion coefficient for hydrogen permeation of steel as 6 x 10-7 cm 2 s -1 at ambient temperature and referenced other literature giving similar values. Applying Fick's second law of diffusion, we can state that: x C( x, t)=co [1 2( 2 Dt π )] Where : C(x,t) is the concentration at distance X from the surface at time t Co is the concentration at the surface

D is the diffusion coefficient of the diffusing species This assumes a constant concentration of hydrogen at Co and this would not happen in practice, but it does give a useful estimation of the rate of diffusion. Applying the values of 6 hours for time (21600 seconds) and a distance of 1mm and a diffusion coefficient of 6 x 10-7 cm 2 s -1, it can be determined that after 6 hours, the concentration of hydrogen at a distance of 1mm below the surface would be 99.7% of the concentration at the surface. This calculation gives a good degree of confidence that the first millimetre of steel would have an approximately homogeneous concentration of hydrogen after a storage time of 6 hours or longer, and agrees with the paper produced by Lovicu et al (1). We can now calculate the hydrogen concentration in the first millimetre of steel as follows: Volume of steel = 0.1 cm 3 for every square centimetre of area. Density of steel = 7.873 g/cm 3 Weight of steel 1mm thick 1cm 2 area = 0.7873 g Atomic weight of iron = 55.85 g/mol Moles of iron = 0.7873/55.85 = 0.0141 Assuming that the hydrogen concentration in the first mm of steel is homogeneous and that all of the hydrogen has been absorbed in the first mm, we can now calculate the hydrogen concentration in atomic ppm and weight ppm: Molar ratio of hydrogen to iron in uninhibited acid = 8.02 x 10-7 / 0.0141 = 5.69 x10-5 In terms of number of atoms, this is a concentration of 56.9 appm In terms of weight ppm, it corresponds to a value of 56.9/55.85 = 1.02 wppm Molar ratio of hydrogen to iron in inhibited acid = 1.51 x 10-7 / 0.0141 = 1.07 x 10-5 In terms of number of atoms, this is a concentration of 10.7 appm In terms of weight ppm, it corresponds to a value of 10.7/55.85 = 0.19 wppm 2. Discussion The results of the calculation show that in a correctly functioning mechanical plating operation, the amount of hydrogen present in the top layer of steel after a 6 hour storage period would not be expected to exceed 0.2 ppm by weight of hydrogen taking the worst case scenario where no hydrogen escapes from the steel into the atmosphere. Lovicu et al (1) performed extensive testing on the effects of hydrogen embrittlement on high tensile steels and determined the critical concentration for hydrogen at which embrittlement commenced. The most susceptible steels to hydrogen embrittlement were hardened Martensitic steels. The critical hydrogen concentration was found to be 1 wppm for M1400 steel and 4 wppm for M1200 steel. Various steels were tested at a hydrogen concentration of 0.4 wppm and no hydrogen embrittlement was found in any of these instances, even with the hardest steels. They concluded that a concentration of 0.4 wppm or less of hydrogen was likely to be safe for any hardened steel. As the calculated value for the mechanical plating operation is well below this threshold, it is very unlikely that the mechanical plating operation would give rise to any hydrogen embrittlement unless the processed bolts were tensioned immediately after plating. The results show the importance of using the correct inhibitors during the mechanical plating operation.

Conclusions 1. The maximum amount of hydrogen in the surface of steel substrates during mechanical plating was calculated to be 0.19 wppm using the Macuguard process and 1.02 wppm using uninhibited acid. 2. The maximum concentration of hydrogen when using the Macuguard process is below the safe threshold of 0.4 wppm suggested by Lovicu et al. 3. From the results of the calculation, it would not be expected that the mechanical plating process would cause hydrogen embrittlement issues. References 1. Hydrogen Embrittlement of Automotive Advanced High Strength Steels Lovicu et al. Metallurgical and Materials Transactions 43A November 2012 4075-4087 T. Pearson 4/2/2015