Armstrong World Industries CAMPUS CORPORATE HEADQUARTERS BUILDING 701

Similar documents
The USGBC booklet, LEED for Existing Buildings: Operations

LEED EB:OM Credit Catagories

LEED Application Guide for Multiple Buildings and On-Campus Building Projects

Prerequisite. prerequisite.

LEED for Existing Buildings:

Crawford House Office Building

500 WEST PUTNAM AVENUE GREENWICH, CT

Using LEED EB to Green Your Facilities. James Baker, LEED AP Director of Facilities

L E E D S C O R E C A R D ( B U I L D I N G D E S I G N & C O N S T R U C T I O N )

Welcome ESC Educational Webinar Green Performance Contracting

Project Summary. Sustainability Facts. LEED for New Construction Rating (out of 69 possible points) Total Score 40 Sustainable Sites 7

2016 LEED Equivalency Analysis for Stanford Campus

What s New in LEED O+M v4: Get Ready for the Future! A Presentation by The Sustainability Experts Leonardo Academy At NFMT Las Vegas

LEED-CI ANALYSIS 1 LANDMARK SQUARE STAMFORD, CT

Sustainable Design A DIVISION OF SHIVE-HATTERY

CONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability

HPBS [ HIGH PERFORMANCE BUILDING STANDARD]

LEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods

Orange County Sanitation District SP-194 Section 06 Sustainability

1st Floor. The Hunt Library Sustainability Tour

LEED-CI ANALYSIS 140 GRAND STREET WHITE PLAINS, NY

LEED-CI ANALYSIS 4 LANDMARK SQUARE STAMFORD, CT

LEED -Existing Buildings. Crescent Ridge Corporate Center I

LEED-CI ANALYSIS 6 LANDMARK SQUARE STAMFORD, CT

Dell Seton Medical Center at The University of Texas Overview

Analysis 1. LEED Analysis of Laboratory Buildings. Penn State School of Forest Resources University Park, PA

California State University, Sacramento February 24, 2010

GLADYS VALLEY HALL. Materials & Resources Innovation & Design Process

Environmental Stewardship Conference October 05, 2013 Energy Water and Sustainability (EWaS) Program

LEED-CI ANALYSIS 115 STEVENS AVENUE VALHALLA, NY

Special Mention, Architecture + Sustainability

LEED Application Guide for Multiple Buildings and On Campus Building Projects

LEED 2009 for New Construction and Major Renovations

Lincoln Public Schools 5 MA-CHPS Schematic Design. 5.1 MA-CHPS Scorecard. 5.2 Certifi cation Goals Letter

Prerequisites must be achieved. Non-compliant prerequisites must be resolved before a certification can be awarded.

Jersey City Public Safety Communications Center

37% 100% 100% PROJECT HIGHLIGHTS LEED Facts. Wiener Auditorium

CE Option 1 and 2 - Provide the pre-development site run -off rate (cfs) CE Option 1 and 2 - Provide the pre-development site run -off quantity (cf)

Duke Sustainability Sands Parking Garage

75% 40% reduction in water consumption. 43% 68% 90%

Phillips Exeter Academy

IFMA Central Pennsylvania Chapter August 20, 2014

How to Interpret this Report

Sustainable Sites (SS): where the building is located matters. SSc1 Site Selection

- AIA Honor Award for Interior Architecture - ALA/IIDA Library Interior Design Awards: Best

Construction Specifications Canada Conference May 23, BOMA BESt

LEED Certified Health Center


2012 USGBC Central Florida Chapter LEEDership Awards Outstanding Green Building of the Year: Valencia College, Lake Nona Campus Valencia College s

ASC New Building 400 Masthead Street Albuquerque, NM

THE ECONOMICS OF LEED FOR EXISTING BUILDINGS FOR INDIVIDUAL BUILDINGS 2008 EDITION A WHITE PAPER APRIL 21, 2008

Green Charrette BANCROFT ELEMENTARY SCHOOL GREEN CHARRETTE

Building Sustainability

LEED Best Practices Save $$$

SECTION SUSTAINABILITY CERTIFICATION REQUIREMENTS LEED NC V3

Green Buildings Make Cents

APPENDIX 01: SAMPLE PRODUCT SUBMITTAL FORM (3 pages) URBAN ARTS ARCHITECTURE Abbott St, Vancouver, BC V6B 2K4 (604)

Synergies & Trade-offs: IP category

Sugen Building 3 LEED-CI Pilot Project

Green Smart. BUILDING Building SITE/LANDSCAPE ENERGY WATER INDOOR AIR QUALITY MATERIALS

LEED & INCENTIVES. Alison Y. Rivenburgh, LEED AP

The Application of LEED Green Building Rating System in Indonesia

Colorado Mountain College: Sustainable Design Standards

ELG4126 Sustainable Development for Electrical Engineers

Introduction to Integrated Sustainable Design

Eaton Center - Shanghai LEED CI Certification Project

SACRAMENTO County New Animal Care Facility LEED Elements

Architecture and Acoustic Design in Green Buildings

Appendix C APPLICATION #: ADDRESS: CITY OF SANTA CRUZ GREEN BUILDING PROGRAM GREEN POINTS CHECK LIST FOR NON-RESIDENTIAL BUILDINGS

Case Study: Element PROJECT DESCRIPTION

Allowance Table for: General:

Green Assistance Program Orientation Meeting March 22, August 5, 2010

LEED for Operations and Maintenance

Projected actual points. Responsible for UNC -- Project name. Remarks

Research Analysis: Building Envelope and LEED Credits Introduction

University of Illinois Business Instructional Facility LEED Gold Design. University of Illinois. University of Illinois

CALGreen 2013 Tier Comparison to LEED v4

Introduction to LEED v4 Lyle Scott May 22, 2014

NPS Project Sustainability Checklist Building Projects (For New Construction or Major Renovation)

96% 33% 30% PLATINUM B1 ANNEX - NORTHWEST LABS BUILDING. PROJECT HIGHLIGHTS LEED Facts

LEED v4: the program

BUILDING FOR OUR FUTURE

Ecole Connaught Community School Welcomes. CaGBC Sask Chapter Members & Colleagues

Leased Space Environmental and Energy Efficiency Attributes Tenant Instructions

E W ENTRANCE E W ATRIUM E W N S LOBBY N S PARKING N S RETAIL BLOCK SECTION - NORTH/SOUTH 0' 16' 32' 64' Seal/Signature OFFICE. Date.

Introduction to Integrated Sustainable Design

LEED for Commercial Interiors

McCollum Hall Classroom Renovation Project Profile LEED-CI Gold, August 2007

WMU Facility Life Cycle Design Guidelines Update (Approved by VP Van Der Kley & Facilities Management on 4/28/16)

CITY COUNCIL AGENDA REPORT

Understanding the 2010 California Green Building Standards Code

1) MERV (Minimum Efficiency Reporting Value) is relevant to which ASHRAE standards in LEED v4? (Choose 2)

CALGREEN NON-RESIDENTIAL BUILDING Checklist

The Fort Collins Discovery Museum LEED stands for Leadership in Energy and Environmental Design.

SUSTAINABILITY & LEED. Mayra Portalatin, LEED AP O + M

Exemplary Performance

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Griswold Hall 2-South Suite and Main Entry Renovation LEED-CI Platinum September 2008

Transcription:

Armstrong World Industries CAMPUS CORPORATE HEADQUARTERS BUILDING 701

Here are just a few of the many initiatives that made significant contributions enabling Building 701 to again be recognized for excellence in sustainable design OPTIMIZE ENERGY EFFICIENCY: Building 701 is recognized by the U.S. Environmental Protection Agency for demonstrating superior energy performance, earning Energy Star certification for each year for six consecutive years. It performs better than 80% of peer buildings, ranking it among the Top 25% of energy-efficient buildings in the U.S. EAc1 LED LIGHTING: Lighting in Building 701 was switched to LED, saving more than 82,966 KW hours. EAc1 ON-SITE AND OFF-SITE RENEWABLE ENERGY: 100% of total annual energy budget is offset by purchasing renewable energy equivalent to removing nearly 4m lbs of CO2 from the atmosphere and taking nearly 1,013 cars off the road. EAc4 STORMWATER QUANTITY CONTROL: We effectively manage stormwater runoff throughout the Campus through well landscaped and manicured retention basins to retain associated stormwater on-site. The goal is to control erosion and to minimize the possible pollution of natural water flows. SSc6 HEAT ISLAND REDUCTION ROOF: The roof area is covered with a highly reflective roof with 0.83 reflective value and 0.88 emittance, aiding in reducing heat islands. A maintenance program is in place to ensure that all SRI surfaces are cleaned at least every three years. SSc7.2 INNOVATION CREDIT FOR ACOUSTICS: In 2007, Building 701 became the first commercial building to earn an Innovation credit for its superior acoustic design; and in 2014 is recertified to meet this level of performance. Superior acoustic performance is achieved with the combination of sound absorption from Armstrong Optima 1" thick acoustical ceiling panels (AC 200), sound blocking from the furniture systems (STC 25), and covering background noise with our i-ceilings Sound Masking System (48 dba +/-2dB spatial variation). The result 29% higher worker satisfaction ratings, improved speech privacy, and a quieter, more pleasant place to work. IOc1 INDOOR AIR QUALITY BEST MANAGEMENT PRACTICES: Our IAQ management plan is based on EPAI BEAM (EPA s Indoor Air Quality Building Education and Assessment Model ) program ensuring that all equipment is maintained and operating properly to provide good indoor air quality for Armstrong staff and visitors, to reduce energy expenditures, and to minimize negative impacts on the environment. EQc1 OCCUPANT COMFORT: 74% of the building occupants participated in the CBE (Center for Built Environment) survey to gain their feedback on occupant comfort and their satisfaction of the building environment. High satisfaction ratings were given for Acoustics, IAQ, Cleanliness, and Maintenance. Yearly surveys are conducted to monitor building satisfaction. EQ2.1 SUSTAINABLE POLICIES SOLID WASTE MANAGEMENT: Our solid waste policy covers all aspects of waste management operations throughout our campus, from consumables and durable goods to facility alterations and additions. MRp2; MRc7,8,9

PERFORMANCE MEASUREMENT BUILDING AUTOMATION AND METERING: Building HVAC and lighting are controlled for maximum energy efficiency by Johnson Controls Metasys PMI building automation system. The system is used campus wide to improve efficiencies of building operations resulting in energy savings. The HVAC system uses energy-efficient motors, CFC- and HCFC-free refrigeration, energy management software, and is zoned into small areas for precise climate control. EAc3 EXISTING BUILDING COMMISSIONING: The first cycle of commissioning occurred in 1998 when the facility was first constructed; the second for the initial LEED -EB certification and recommissioning in 2006 to 2007; and the third cycle of commissioning in January 2014 for the LEED-EB recertification. HVAC: Perform Re-Commissioning of Building Systems an approximate 10% - 20% total energy savings when completed. A plan was created identifying opportunities for cost-effective reductions in energy consumption; operating efficiencies and capital improvements all expected to provide ongoing cost savings. EAc2 SUSTAINABLE POLICIES PURCHASING: Items purchased for Corporate Campus Building 701 follow a strict sustainable purchasing policy. For Electronics, all items must meet Energy Star and EPEAT (Electronic Product Environmental Assessment Tool). All vendors are responsible for providing sustainable options and reduced packaging options for all purchases. MRp1; MRc1,2,4 WATER PERFORMANCE MEASUREMENT: Water meters measure the total amount of potable water use in the building and associated grounds. Meters include a 4" Neptune compound meter for domestic water for the entire building and a 3/4" Sensus meter for the building humidification system. The metered data is read weekly by the boiler operator, who records the information, which is submitted to the Maintenance CMMS analyst. WEc1 DAYLIGHTING: The glass and steel building is designed with a shallow floor plan that allows natural daylight to fill more than 55% of the workspace. Interior light shelves reflect sunlight onto Armstrong high light reflectance ceilings to minimize the need for energy-consuming lighting. EQc2.4 LIGHT SHELVES: The building architecture incorporates two light shelves. The exterior light shelves shade the windows, reduce glare, and minimize solar heat gain during the summer. The interior light shades reflect sunlight onto the Armstrong high light reflectance ceilings to increase the energy-saving benefits of daylighting. EQc2.2 INDIRECT LIGHTING: To supplement the significant use of daylighting, high light reflectance ceilings, indirect lighting systems, and control systems exceed the requirements of the Illuminating Engineering Society (IES). Lighting energy is reduced to half the nationwide average for comparable office buildings. EQc2.2 CONTROLLABILITY OF LIGHTING SYSTEMS: It s simple. When the offices aren t occupied, the lights go off automatically, saving energy. 100% of the offices have individual control. Workstations have task lighting that is controllable by the occupant. The combination of occupancy sensors and dual-switch lighting systems minimize the use of artificial light and related heat gain. EQc2.2 Economically profitable, environmentally responsible

Recognized for excellence GREEN CLEANING POLICY: Our comprehensive green cleaning plan includes environmentally responsible cleaning, janitorial maintenance, occupant training, isolation of chemical storage, sustainable supplies, use of concentrates from dispensing equipment, disposable housekeeping products, carpet care, and floor stripping all part of the ABM Janitorial Services GreenCare Program. Daylighting housekeeping, instituted in 2014, saves more than $150,000 per year in related energy costs. EQc3 SITE DEVELOPMENT PROTECT AND RESTORE OPEN HABITAT: Our comprehensive site management plan helps us protect the environment and use resources wisely. That s why the grass is mowed only when necessary, all landscape waste is composted, maintenance equipment meets California emissions standards and is routinely serviced by a licensed mechanic, and operators wear personal protective equipment. SSc1 BUILDING EXTERIOR AND HARDSCAPE MANAGEMENT PLAN: Our best management practices significantly reduce environmental impacts for equipment maintenance, snow removal, cleaning, and overall campus maintenance and upgrades. Our goal is to eliminate/minimize the impact of potentially harmful chemical release into the air and soil. Our policies outline best practices that are a standard for the entire Armstrong Campus. SSc2 ALTERNATIVE COMMUTING TRANSPORTATION: 50% of occupants commute to work using fuel-efficient or hybrid automobiles or via alternative means of transportation, including walking, bicycles, carpools, and public transportation. Saving energy going to and from work is as important as on-site energy savings. SSc4 SOLID WASTE MANAGEMENT AUDIT: 62% of the building s total waste is recycled. This exceeds LEED criteria by 13%. MRc6 WATER EFFICIENT LANDSCAPING: There is no permanent irrigation system installed on the grounds. Native plantings provide efficiency and save water use. WEc2 EDUCATION: We re committed to sharing the green building features of Building 701 with others through an educational outreach program that includes guided tours of the facility, as well as internal and external communications. We have over 1,000 annual visitors. IOc1.4 INDOOR PLUMBING FIXTURE AND FITTING EFFICIENCY: Indoor plumbing fixtures and fittings comply with the UPC (Universal Plumbing Code) or IPC (International Plumbing Code) and reduce water usage in the building by 45 percent. Low-flow aerators, waterless urinals, and dual-flush toilets have driven greater than 50% reduction from the Existing Building baseline with a savings of 380,000 gallons per year. WEc3

IN APRIL OF 2014, the U.S. Green Building Council awarded LEED for Existing Building Platinum Recertification to Armstrong World Industries Corporate Headquarters. Originally earning this distinction in 2007, Armstrong Corporate Headquarters is the first building in Pennsylvania, and among only 17 buildings globally, to earn recertification at the highest level possible under USGBC s LEED Existing Buildings: Operations and Maintenance (EBOM) program. The Leadership in Energy and Environmental Design (LEED) rating system was created by the U.S. Green Building Council to encourage and facilitate the development of more sustainable buildings. LEED-EB rates existing buildings in an effort to promote buildings that are economically profitable, environmentally responsible, and healthy, productive places to work. Built in 1998, as a green building, and continuing nine years later, the Armstrong Corporate Headquarters is a living example of what is possible when you make a serious commitment to building a healthy, sustainable future. We extend these principles to our entire operation and Corporate campus covering over 1 million square feet of building space, 225 acres, 950 employees. LEED Facts for LEED O+M: Existing Buildings (v2009) Certification awarded Apr 2014 Platinum 88 Sustainable sites 19/26 Water efficiency 13/14 Energy & atmosphere 26/35 Material & resources 8/10 Indoor environmental quality 12/15 Innovation 6/6 Regional priority credits 4/4

SUSTAINABLE PRODUCTS: Ceilings All Ultima ceiling panels have no-added formaldehyde and meet the CDPH requirements for low emissions. High Light Reflectance Ceilings High Recycled Content (HRC) Ceilings Suspension systems are made from metal with recycled content. All ceilings are recyclable as part of the Armstrong Ceiling Recycling Program. Walls WoodWorks Ekos walls are made from real wood veneer over a mineral fiber substrate, with no-added formaldehyde, 78% recycled content, and recyclable. project contributors include: Re:Vision Architecture LEED Consultant Bala Consulting Engineers Commissioning Agent Johnson Controls One Source Green Sweep Community Energy David Miller / Associates Civil Engineer Gensler Building Architect Barclay White (Now SKANSKA) Original Construction Manager Flooring Translations flooring is FloorScore certified for low VOC emissions according to CA Section 01350. Furniture Herman Miller furniture systems are designed to evolve as work changes, maintaining high performance. Ethospace system helps block unwanted noise and contributes to privacy in open office areas. Glass tiles allow more light into the space; open returns and up-mounted storage reduce materials usage and the system is up to 78% recyclable. armstrong.com/environmental This brochure is recyclable. Printed with vegetable-based inks on paper utilizing 100% post consumer waste. LEED is a registered trademark of the U.S. Green Building Council All other trademarks used herein are the property of AWI Licensing Company and/or its affiliates 2014 AWI Licensing Company. Printed in the United States of America. BPCF-4936-1114