Multi-Institutional Academic Health Science & Research Center Evansville, IN

Similar documents
Addendum No. 1 November 03, 2016

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

A. Dimension Lumber: Lumber of 2 inches nominal or greater but less than 5 inches nominal in least dimension.

A. Product Data: For each type of process and factory-fabricated product.

SECTION ADDENDA ADDENDUM NUMBER 2

SUNY Cortland Renovations To Moffett Center Phase 2 Cortland, NY 13045

SECTION GYPSUM BOARD

SECTION CEMENTITIOUS SHEATHING

SECTION STRUCTURAL INSULATED PANELS

SECTION GYPSUM BOARD

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

SECTION Fiber Reinforced Stucco 1

Magnum Board Section Digicon Information Inc. Page 1

Gypsum Board

Magnum Board Section Digicon Information Inc. Page 1

SECTION THERMAL INSULATION

A. Product Data: For each type of process and factory-fabricated product.

Gold Bond BRAND Gypsum Sheathing

GA APPLICATION OF GYPSUM SHEATHING

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

EDGEWATER, FLORIDA JUNE 14, 2010

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION COLD-FORMED METAL TRUSSES

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

SECTION GYPSUM BOARD ASSEMBLIES

Lamit Industries, Inc. 710 Marion Road Columbus, Ohio P-(614) F-(614)

A. Meet at Project site <insert number> days before starting installation.

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

Boards or Strips: Lumber of less than 2 inches nominal size in least dimension.

Construction Standards PAGE

DIVISION 06 WOOD, PLASTICS, AND COMPOSITES

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

LUX Specifications. Section S - Preformed Steel Siding

A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer's written instructions, whichever are more stringent.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION COLD-FORMED METAL FRAMING

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

GAF EnergyGuard Polyiso Wall Sheathing

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION MANUFACTURED ROOF EXPANSION JOINTS

A. Section includes fluid applied, vapor permeable membrane air barriers.

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Note to Specifier: Use this product for coated glass-mat faced polyisocyanurate insulation boards such as Rboard.

East Central College

Architectural Wall Products Guide Specifications

SECTION Arisfor WallGuard

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

HIGH PERFORMANCE FIRE RETARDANT TREATED WOOD PRODUCTS

SECTION ROUGH CARPENTRY

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

Architectural Roof and Wall Products Guide Specifications

1. Interior gypsum board. 2. Glass-mat gypsum sheathing board for ceilings and soffits. 3. Cement board. 4. Sound attenuation blankets

SECTION CEMENTITIOUS WOOD FIBER DECKS

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11

SECTION NON--STRUCTURAL METAL FRAMING

Construction Standards PAGE

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

SECTION COLD-FORMED METAL FRAMING

Copyright 2010 AIA MasterSpec Short Form 02/10 PRODUCT MASTERSPEC LICENSED BY ARCOM TO GEORGIA-PACIFIC GYPSUM LLC

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES

SECTION GYPSUM BOARD

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

Code Compliance Research Report CCRR-0228

SECTION GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION GYPSUM BOARD SYSTEM

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

REPORT HOLDER: STAR R FOAM MANUFACTURING, INC. EVALUATION SUBJECT: STAR R FOAM INSULATION BOARDS

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

A. Product Data: For each type of product specified.

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

COMPOSITESIDING

(Project Location) (your firm's name)

EDGEWATER, FLORIDA JUNE 14, 2010

SECTION GYPSUM BOARD SYSTEM

SECTION GYPSUM BOARD

Architectural Roof and Wall Products Guide Specifications

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

SPECIFICATION GUIDELINE

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

Retain "Preinstallation Conference" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Transcription:

SECTION 061600 - SHEATHING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section for the Core & Shell Contract. 1.2 SUMMARY A. Section Includes: 1. Wall, Parapet, Roof and Soffit sheathing. 2. Sheathing joint and penetration treatment. B. Related Requirements: 1. Section 054000 "Cold Formed Metal Framing". 2. Section 071413 "Fluid Applied Membrane". 3. Section 072100 Building Insulation and Safing. 1.3 ACTION SUBMITTALS A. Product Data: For each type of process and factory-fabricated product. Indicate component materials and dimensions and include construction and application details. 1. Include data for wood-preservative treatment from chemical treatment manufacturer and certification by treating plant that treated plywood complies with requirements. Indicate type of preservative used and net amount of preservative retained. 2. Include data for fire-retardant treatment from chemical treatment manufacturer and certification by treating plant that treated plywood complies with requirements. Include physical properties of treated materials. 3. For fire-retardant treatments, include physical properties of treated plywood both before and after exposure to elevated temperatures, based on testing by a qualified independent testing agency according to ASTM D 5516. 4. For products receiving waterborne treatment, include statement that moisture content of treated materials was reduced to levels specified before shipment to Project site. B. LEED Submittals: 1. Certificates for Credit MR 6and Credit MR 7: Chain-of-custody certificates indicating that products specified to be made from certified wood comply with forest certification requirements. Include documentation that manufacturer is certified for chain of custody by an FSC-accredited certification body. Include statement indicating cost for each certified wood product. SHEATHING 061600-1

2. Product Data for Credit IEQ 4.1: For adhesives, documentation including printed statement of VOC content. 3. Laboratory Test Reports for Credit IEQ 4.1: For adhesives, documentation indicating that products comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." 4. Product Data for Credit IEQ 4.4: For composite wood products, documentation indicating that product contains no urea formaldehyde. 5. Laboratory Test Reports for Credit IEQ 4.4: For composite-wood products, documentation indicating that products comply with the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers." 6. Product Data for Credit MR 4: For products having recycled content, documentation indicating percentages by weight of postconsumer and pre-consumer recycled content. Include statement indicating cost for each product having recycled content. 7. Product Certificates for Credit MR 5: For products and materials required to comply with requirements for regional materials, certificates indicating location of material manufacturer and point of extraction, harvest, or recovery for each raw material. Include statement indicating distance to Project, cost for each regional material, and fraction by weight that is considered regional. 1.4 INFORMATIONAL SUBMITTALS A. Evaluation Reports: For the following, from ICC-ES: 1. Wood-preservative-treated plywood. 2. Fire-retardant-treated plywood. 1.5 QUALITY ASSURANCE A. Testing Agency Qualifications: For testing agency providing classification marking for fireretardant-treated material, an inspection agency acceptable to authorities having jurisdiction that periodically performs inspections to verify that the material bearing the classification marking is representative of the material tested. 1.6 DELIVERY, STORAGE, AND HANDLING A. Stack panels flat with spacers beneath and between each bundle to provide air circulation. Protect sheathing from weather by covering with waterproof sheeting, securely anchored. Provide for air circulation around stacks and under coverings. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Fire-Resistance Ratings: As tested according to ASTM E 119; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. SHEATHING 061600-2

1. Fire-Resistance Ratings: Indicated by design designations from UL's "Fire Resistance Directory" or from the listings of another qualified testing agency. 2.2 FIRE-RETARDANT-TREATED PLYWOOD A. General: Where fire-retardant-treated materials are indicated, use materials complying with requirements in this article that are acceptable to authorities having jurisdiction and with firetest-response characteristics specified as determined by testing identical products per test method indicated by a qualified testing agency. B. Fire-Retardant-Treated Plywood by Pressure Process: Products with a flame-spread index of 25 or less when tested according to ASTM E 84, and with no evidence of significant progressive combustion when the test is extended an additional 20 minutes, and with the flame front not extending more than 10.5 feet (3.2 m) beyond the centerline of the burners at any time during the test. 1. Use treatment that does not promote corrosion of metal fasteners. 2. Exterior Type: Treated materials shall comply with requirements specified above for fireretardant-treated plywood by pressure process after being subjected to accelerated weathering according to ASTM D 2898. Use for exterior locations and where indicated. 3. Interior Type A: Treated materials shall have a moisture content of 28 percent or less when tested according to ASTM D 3201/D 3201M at 92 percent relative humidity. Use where exterior type is not indicated. 4. Design Value Adjustment Factors: Treated lumber plywood shall be tested according to ASTM D 5516 and design value adjustment factors shall be calculated according to ASTM D 6305. Span ratings after treatment shall be not less than span ratings specified. For roof sheathing and where high-temperature fire-retardant treatment is indicated, span ratings for temperatures up to 170 deg F (76 deg C) shall be not less than span ratings specified. C. Kiln-dry material after treatment to a maximum moisture content of 15 percent. Do not use material that is warped or does not comply with requirements for untreated material. D. Identify fire-retardant-treated plywood with appropriate classification marking of qualified testing agency. E. Application: Treat all plywood unless otherwise indicated: 2.3 WALL, PARAPET, ROOF AND SOFFIT SHEATHING A. Plywood Sheathing: Exposure 1, Structural I sheathing. 1. Basis of Design: Georgia Pacific Plywood. 2. Span Rating: Not less than 24/0. 3. Nominal Thickness: Not less than 5/8 inch (15.9 mm) thick. B. Glass-Mat Gypsum Sheathing: ASTM C 1177/1177M. 1. Basis of Design: DensGlass Gold by G-P Gypsum. 2. Type and Thickness: Type X, 5/8 inch (15.9 mm) thick. SHEATHING 061600-3

3. Size: 48 by 120 inches (1219 by 3048 mm). C. Cementitious Backer Units: ASTM C 1325, Type A. 1. Basis of Design: Dens-Deck by G-P Gypsum. 2. Thickness: 5/8 inch (15.9 mm) thick. 3. Size: 48 by 96 inches (1219 by 2438 mm). 2.4 FASTENERS A. General: Provide fasteners of size and type indicated that comply with requirements specified in this article for material and manufacture. 1. For roof, parapet and wall sheathing provide fasteners with hot-dip zinc coating complying with ASTM A 153/A 153M. B. Nails, Brads, and Staples: ASTM F 1667. C. Power-Driven Fasteners: Fastener systems with an evaluation report acceptable to authorities having jurisdiction, based on ICC-ES AC70. D. Screws for Fastening Sheathing to Wood Framing: ASTM C 1002. E. Screws for Fastening Wood Structural Panels to Cold-Formed Metal Framing: ASTM C 954, except with wafer heads and reamer wings, length as recommended by screw manufacturer for material being fastened. F. Screws for Fastening Gypsum Sheathing to Cold-Formed Metal Framing: Steel drill screws, in length recommended by sheathing manufacturer for thickness of sheathing to be attached. 1. For steel framing less than 0.0329 inch (0.835 mm) thick, use screws that comply with ASTM C 1002. 2. For steel framing from 0.033 to 0.112 inch (0.84 to 2.84 mm) thick, use screws that comply with ASTM C 954. G. Screws for Fastening Composite Nail Base Insulated Roof Sheathing to Metal Roof Deck: Steel drill screws, in type and length recommended by sheathing manufacturer for thickness of sheathing to be attached, with organic-polymer or other corrosion-protective coating having a salt-spray resistance of more than 800 hours according to ASTM B 117. Provide washers or plates if recommended by sheathing manufacturer. 2.5 SHEATHING JOINT-AND-PENETRATION TREATMENT MATERIALS A. Sealant for Glass-Mat Gypsum Sheathing: Elastomeric, medium-modulus, neutral-curing silicone joint sealant compatible with joint substrates formed by gypsum sheathing and other materials, recommended by sheathing manufacturer for application indicated and complying with requirements for elastomeric sealants specified in Section 079200 "Joint Sealants." B. Sealant for Glass-Mat Gypsum Sheathing: Silicone emulsion sealant complying with ASTM C 834, compatible with sheathing tape and sheathing and recommended by tape and SHEATHING 061600-4

sheathing manufacturers for use with glass-fiber sheathing tape and for covering exposed fasteners. 1. Sheathing Tape: Self-adhering glass-fiber tape, minimum 2 inches (50 mm) wide, 10 by 10 or 10 by 20 threads/inch (390 by 390 or 390 by 780 threads/m), of type recommended by sheathing and tape manufacturers for use with silicone emulsion sealant in sealing joints in glass-mat gypsum sheathing and with a history of successful in-service use. 2.6 MISCELLANEOUS MATERIALS PART 3 - EXECUTION 3.1 INSTALLATION, GENERAL A. Do not use materials with defects that impair quality of sheathing or pieces that are too small to use with minimum number of joints or optimum joint arrangement. Arrange joints so that pieces do not span between fewer than three support members. B. Cut panels at penetrations, edges, and other obstructions of work; fit tightly against abutting construction unless otherwise indicated. C. Securely attach to substrate by fastening as indicated, complying with the following: 1. Table 2304.9.1, "Fastening Schedule," in the ICC's International Building Code. 2. Table R602.3(1), "Fastener Schedule for Structural Members," and Table R602.3(2), "Alternate Attachments," in the ICC's International Residential Code for One- and Two- Family Dwellings. 3. ICC-ES evaluation report for fastener. D. Use common wire nails unless otherwise indicated. Select fasteners of size that will not fully penetrate members where opposite side will be exposed to view or will receive finish materials. Make tight connections. Install fasteners without splitting wood. E. Coordinate wall, parapet and roof sheathing installation with flashing and joint-sealant installation so these materials are installed in sequence and manner that prevent exterior moisture from passing through completed assembly. F. Do not bridge building expansion joints; cut and space edges of panels to match spacing of structural support elements. G. Coordinate sheathing installation with installation of materials installed over sheathing so sheathing is not exposed to precipitation or left exposed at end of the workday when rain is forecast. 3.2 WOOD STRUCTURAL PANEL INSTALLATION A. General: Comply with applicable recommendations in APA Form No. E30, "Engineered Wood Construction Guide," for types of structural-use panels and applications indicated. SHEATHING 061600-5

B. Fastening Methods: Fasten panels as indicated below: 1. Wall and Roof Sheathing: a. Screw to cold-formed metal framing. b. Space panels 1/8 inch (3 mm) apart at edges and ends. 3.3 GYPSUM SHEATHING INSTALLATION A. Comply with GA-253 and with manufacturer's written instructions. 1. Fasten gypsum sheathing to cold-formed metal framing with screws. 2. Install panels with a 3/8-inch (9.5-mm) gap where non-load-bearing construction abuts structural elements. 3. Install panels with a 1/4-inch (6.4-mm) gap where they abut masonry or similar materials that might retain moisture, to prevent wicking. B. Apply fasteners so heads bear tightly against face of sheathing, but do not cut into facing. C. Horizontal Installation: Install sheathing with V-grooved edge down and tongue edge up. Interlock tongue with groove to bring long edges in contact with edges of adjacent panels without forcing. Abut ends over centers of studs, and stagger end joints of adjacent panels not less than one stud spacing. Attach at perimeter and within field of panel to each stud. 1. Space fasteners approximately 8 inches (200 mm) o.c. and set back a minimum of 3/8 inch (9.5 mm) from edges and ends of panels. 2. For sheathing under stucco cladding, panels may be initially tacked in place with screws if overlying self-furring metal lath is screw-attached through sheathing to studs immediately after sheathing is installed. D. Vertical Installation: Install vertical edges centered over studs. Abut ends and edges with those of adjacent panels. Attach at perimeter and within field of panel to each stud. 1. Space fasteners approximately 8 inches (200 mm) o.c. and set back a minimum of 3/8 inch (9.5 mm) from edges and ends of panels. 2. For sheathing under stucco cladding, panels may be initially tacked in place with screws if overlying self-furring metal lath is screw-attached through sheathing to studs immediately after sheathing is installed. E. Seal sheathing joints according to sheathing manufacturer's written instructions. 1. Apply elastomeric sealant to joints and fasteners and trowel flat. Apply sufficient amount of sealant to completely cover joints and fasteners after troweling. Seal other penetrations and openings. 2. Apply glass-fiber sheathing tape to glass-mat gypsum sheathing joints and apply and trowel sealant to embed entire face of tape in sealant. Apply sealant to exposed fasteners with a trowel so fasteners are completely covered. Seal other penetrations and openings. SHEATHING 061600-6

3.4 CEMENTITIOUS BACKER UNIT INSTALLATION A. Install panels and treat joints according to ANSI A108.11 and manufacturer's written instructions for type of application indicated. END OF SECTION 061600 SHEATHING 061600-7

This page intentionally left blank. SHEATHING 061600-8