GRP JACKING PIPES FOR MICRO-TUNNELING

Similar documents
FLOWTITE GREY HIGH IMPACT GRP PIPE

THE FIRST CHOICE OF ENGINEERS WORLDWIDE LOW RESOLUTION! EUROPEAN OPERATIONS

DISTRIBUTED BY EMPIRE INFRASTRUCTURE PTY LTD

CONTINUOUS FILAMENT WOUND GRP PIPE FOR USE IN JACKING APPLICATIONS

GRP PIPE PRODUCTS FOR USE IN IRRIGATION PROJECTS

Reliable GRP pipe systems for potable water supply

Quality from raw material to pipe connection

We have enough water if we manage it well

Superior GRP pipes for today s sewer challenges

FLOWTITE Pipe Systems. For Subaqueous Installations LOW RESOLUTION!

ITEM NO SLIPLINING SANITARY SEWERS

CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE

Top Performance Pipes for Toughest Conditions

FLOWTITE Case Studies. - Stormwater Systems - LOW RESOLUTION PDF

ISO/TS TECHNICAL SPECIFICATION

Dynaflow Lectures - March 26 th Fiberglass Pipe Systems

Experts in tunneling with Tunnel Boring Machines

ISO INTERNATIONAL STANDARD

An introduction to. pipe jacking

Expert in Tunneling Systems & Trenchless Technology (HDD, Microtunneling, Pipe Jacking, Thrustboring, Sheet Piling)

THERMOPLASTIC MANHOLES FOR AND OUT OF LARGE DIAMETER PIPES

Glass-fibre reinforced polyester (GRP) pipe systems PRODUCT GUIDE

Pipeline Rehabilitation

ADDENDUM NO. 4. Project Name: Olmos Basin Central Watershed Sewer Relief Line (C-3), Reaches 1 to 4

PDF VERSION. Connecting the World with its Future. Amiantit in Brief. A World Class Partner

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS

Denlok Performance Advantages

ISO INTERNATIONAL STANDARD

PDF VERSION. Yansab Yanbu, Saudi Arabia. Overview. Project

Khalid SINCE 1997 TECHNICAL MANUAL 2017 GRP MANHOLE LINER & ACCESSORIES

BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

Design, Specification and Selection of Concrete Jacking Pipes Who Decides? What Really Matters?

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

PIPE in PIPE instead of replacing existing pipes!

ISO INTERNATIONAL STANDARD

It is also a recognised supervisory body for CIPP liners and glass-fibre-reinforced plastic (GRP) short-liners.

CS-13 TRENCHLESS TECHNOLOGY TABLE OF CONTENTS

ENGINEERING SPECIFICATION NON-MAGNETIC RAISED FLOOR SYSTEM FOR MRI ROOM APPLICATIONS

Fibre reinforced thermosetting plastic piping systems - Non-metallic materials

FLOWTITE Pipe Systems. For Hydropower and Penstock Applications LOW RESOLUTION PDF

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

BONDSTRAND Glassfiber Reinforced Epoxy Piping Systems for Offshore Applications

When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply.

FLOWTITE ENVIRONMENTAL PRODUCT DECLARATION

When a standard or other referenced document referred to in this specification is superseded by an approved revision, the revision shall apply.

TAMDID PIPES GRP MANHOLE BROCHURE

SRPE AASHTO Specifications.

COMPANY PROFILE. HARKE Capability Statement. Insideout

PERFECT PIPE THE REVOLUTION CONTINUES

Improve Your Asset Integrity. LOCTITE Composite Pipe Repair and Flange Sealing System

The Concept of Value Engineering in Application of GRP Pipes for Water and Sewage Transmission

INIZIATIVE INDUSTRIALI

Concrete Pipe Jacking

No-Dig Technology is the art and science of pipes, ducts and cables using techniques that minimizes / eliminates the need for excavation, i.e.

Characteristics and Typical Uses of PE100 RC Materials and Pipes. MCsSz Conference, Budapest January 2017 Dr. Patrik Schneider, PE100+ Association

Characteristics. PE-GFR pressure pipes

Reinforced Concrete Microtunnelling Pipe Designed for Project Conditions and MTBM Machines

TRENCHLESS CONSTRUCTION (BORING, JACKING, AND TUNNELING)

SAMPLE SPECIFICATIONS FOR PREFABRICATED FRP LIFT STATIONS

Product Guide Specification

Current Status of Sewer Network Renovation in Europe and the Activities of CEN

THE ADVANTAGES HDPE MANHOLES

HYDRO POWER SOLUTIONS

h Sewer Pipe Systems

GRP hydropower solutions for turning fresh water into energy

For winding pipe technology

Concrete Pipe Jacking

Cured-in-Place Pipe (CIPP) for Pressure Pipe. Presented by: Mike Moore

Large plastic pipe technology. Large diameter pressure pipe. up to DN/ID 5000 mm

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

Gasketed Sewer Pipe. Storm and Sanitary pipe for use with Gasketed Sewer Fittings.

Fiberglass Epoxy GRE Integral Joint Tubing

h Installation Manual

Specifications for SWC #110: Pipe, Pipe Liner, & Liner Installation

MECHANICAL TEST FIXTURES

SPECIFICATIONS FOR PREMIER-PIPE USA CURED-IN-PLACE TECH LINER

INDEX -INTRODUCTION -PREFABRICADOS DELTA PIPING SYSTEM -ADVANTAGES OF CONCRETE PRESSURE PIPE -PRESTRESSED CONCRETE PRESSURE PIPE WITH STEEL-CYLINDER

Weholite LIGHTWEIGHT PIPE SYSTEM

SEwEr rehabilitation Spr technologies

INDEX FOR SPECIFICATIONS FOR JACKING CULVERTS THROUGH EMBANKMENTS SCOPE... 2

GREEN THREAD Piping Systems

Pipeline renovation with Omega-Liner close-fit lining

TECHNICAL PARTS FOR YACHTING

Sclairpipe VERSATILE HIGH DENSITY POLYETHYLENE PIPE

Independent certification of your products & services. 2.2 Relevant Standards 1. SCOPE

Soft-Eye. Turnkey solution for efficient boring of reinforced concrete structures.

Presented by: Thermoplastic Piping

GLASSFIBER REINFORCED PLASTICS (GRP) MOULDED AND PULTRUDED GRATING

Series 4000 Fiberglass Pipe and Fittings

Sectional repair of Pipes and Sewers

Durostone Fibre reinforced plastics. PCB solder pallet materials

MERIFLEX PE PRESSURE PIPES DATA SHEET

International Aramoon Corp. Pipe Inspection and Rehabilitation By: Faiz Al-Elweet. SAWEA Al-Khobar KSA February 24, 2010

Bondstrand Series 3000A Fiberglass Pipe for General Industrial Service

SIROPLAST-K. Pipe system for civil engineering subsoil drainage inspection chambers and subsoil drainage pipes to DIN

ECONOMIC EVALUATION OF PIPELINES (CASE STUDY)

Large polyethylene pipes

Ultimate Pipeline Systems POWER PLASTIC FACTORY LLC.

Tunnelling steel pipe systems. Cost-efficient, flexible, reliable.

Special Works Division

Transcription:

GRP JACKING PIPES FOR MICRO-TUNNELING Flowtite Products For Pipe Jacking, Micro-Tunnelling and Sliplining

FLOWTITE GRP JACKING PIPES Flowtite GRP Jacking Pipes are designed and manufactured for the construction and renovation of belowground pipelines using trenchless methods. They are recognised and chosen for their high axial compressive strength and ring stiffness and provide significant advantages compared to other pipe materials. Flowtite GRP Jacking Pipes are supplied with a range of high performance coupling systems suitable for micro-tunnelling and pipe jacking. The Flowtite GRP Jacking Pipe product range consists of: Standard jacking pipes Jacking pipes with injection nozzles Jacking pipes for intermediate jacking stations Relining pipes Specially tailored fittings and manholes Jacking pipe joints APPLICATIONS FOR FLOWTITE GRP JACKING PIPES Flowtite GRP Jacking Pipes are suitable for the construction of new sewer and pressure pipelines, replacement of old sewers, road culverts in transport engineering and relining using the following trenchless methods of construction: Micro-tunnelling Hydraulic jacking with remote control drilling Free boring Sliplining Flowtite GRP Jacking Pipes can be installed in: Straight or curved alignments Cohesive and non-cohesive soils Dry or high water table conditions

MANUFACTURE Flowtite GRP Jacking Pipes are manufactured worldwide in Europe, America, Asia, Australia and Africa. A continuous winding and advancing mandrel process is used to produce a dense laminate which maximises the contributions of the raw materials. The process allows high production output compared with other manufacturing processes. The pipes are manufactured with polyester or vinylester resin, glass fibre, and silica sand. The technology enables the production of a range of pipe sizes and wall thicknesses, allowing for optimal pipe selection. Pipe spigots are machined to the required dimensions and tolerances and assembled with either GRP or stainless steel couplings, depending on the application. All pipes are quality inspected after manufacturing to ensure that they comply with the relevant national and international standards. The typical wall build-up of Flowtite GRP Jacking Pipes TECHNICAL DATA The Flowtite GRP Jacking Pipes manufacturing process allows a wide range of pipe dimensions and properties and is not restricted by outside diameters or pipe lengths. Pipe Lengths The pipe length can be customised according to specific requirements to fit the site conditions and jacking pipe equipment. Such flexibility helps to maximise installation efficiency. Pipe Diameters Flowtite GRP Jacking Pipes can be manufactured to fit the internal diameter of any pipe, ensuring a smooth transition between open trench and jacked pipe. Flowtite GRP transition pipe allows direct jointing of standard trenched pipe to jacking pipe, eliminating the requirement for a maintenance structure. Customised internal and external pipe diameters can be accommodated

FEATURES AND BENEFITS Flowtite GRP Jacking Pipes systems provide: High axial compressive strength for longer single drive lengths, depending on soil conditions and jacking parameters Consistent distribution of concentrated compressive stress (especially in curves) Excellent hydraulic properties Operating temperatures from -50 C to +70 C The high compressive strength of Flowtite GRP Jacking Pipes also allows reduced wall thicknesses compared with other pipe materials, maximising cost savings and optimising the price / performance ratio. Further benefits can be achieved with: Smaller jacking machines Minimum excavation volume Smaller starting pit (thrust block volume) Lower energy consumption Reduced construction time Chemical resistance

MATERIAL PROPERTIES Physical Characteristics The wall construction of Flowtite GRP Jacking Pipes can vary, depending on the stiffness and jacking load requirements. Indicative mechanical properties are provided in the following table. PROPERTIES OF FLOWTITE GRP JACKING PIPES Material density Parameter Longitudinal compressive strength Hoop flexural modulus Value 2 000 2 100 kg/m³ > 90 MPa 12 000 18 000 MPa STANDARDS AND QUALITY Flowtite GRP Jacking Pipes are manufactured acc. to the following relevant standards, under third party certified quality assurance programmes complying with ISO 9001 Quality Management System: ISO 25780:2011 Plastics piping systems for pressure and non-pressure water supply, irrigation, drainage or sewerage Glass reinforced thermosetting plastics (GRP) systems based on unsaturated polyester (UP) resin Pipes with flexible joints intended to be installed using jacking techniques. ISO 10467:2004 Plastics piping systems Glass reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin: Pressure and non-pressure drainage and sewerage. ISO 10639:2004 Plastics piping systems Glass reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin: Pressure and non-pressure water supply. EN 1796:2013 Plastics piping systems for water supply with or without pressure Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP). EN 14364:2013 Plastics piping systems for drainage and sewerage with or without pressure - Glass-reinforced thermosetting plastics (GRP) based on unsaturated polyester resin (UP) Specifications for pipes, fittings and joints. ASTM D3262 Standard Specification for Fiberglass (Glass-Fiber-Reinforced Thermosetting-Resin) Sewer Pipe.

Distributed by Amiantit Service GmbH Am Fuchsloch 19 04720 Döbeln Germany Tel.: + 49 3431 71 82 0 Fax: + 49 3431 70 23 24 info@amiantit.eu Amiantit Germany GmbH Am Fuchsloch 19 04720 Döbeln Germany Tel.: + 49 3431 71 82 0 Fax: + 49 3431 70 23 24 info-de@amiantit.eu Amiantit Poland Sp. z o.o. 43 Św. Michała Street 61-119 Poznań Poland Tel.: + 48 61 650 34 90 Fax: + 48 61 650 34 99 info-pl@amiantit.eu Amiantit Spain, S.A. Polígono Industrial La Venta Nova, 91 43894 Camarles (Tarragona) Spain Tel.: + 34 977 470 777 Fax: + 34 977 470 747 info-es@amiantit.eu Amiantit France 58 bis, Rue de l Ambassadeur 95610 ERAGNY-sur-OISE France Tel.: + 33 1 34 02 06 30 Fax: + 33 1 34 02 30 38 info-fr@amiantit.eu Amiantit Norway AS Østre Kullerød 3, 3241 Sandefjord Norway Tel.: + 47 99 11 35 00 Fax: + 47 33 44 92 00 info-no@amiantit.eu amiantit.eu THE FIRST CHOICE OF ENGINEERS WORLDWIDE 04-16 EN V1 This brochure is intended as a presentation only. Flowtite have separate handbooks and manuals for engineering and installing Flowtite products, which should be used for such purposes. All values listed in the product specifications are nominal. Unsatisfactory product results or applications may occur due to environmental fluctuations, variations in operating procedures, or interpolation of data. We highly recommend that any personnel using this data have specialized training and expertise in the application of the products and their normal installation and operating conditions as well as any particular requirements and the degree of care required for product installation or service. Flowtite does its utmost to ensure that all technical information, data and recommendations are based upon good research and our wealth of experience. We provide the data in this brochure in good faith, and, as such, accept no liability, and will not be held liable, for any losses or damage which may result from the installation or use of any products listed in this brochure. Flowtite companies reserve the right to revise, delete or make obsolete any data and product featured in this brochure without prior notice. We welcome comments regarding this brochure.