ALODINE 1200S. Alodine 1200S is usually made up at 7.5 kg per 1,000 litres of bath.

Similar documents
TECHNICAL INFORMATION GRANODINE 20

ALODINE 5200 CONVERSION COATING PROCESS FOR ALUMINIUM

BONDERITE 1070F CLEANER/COATER PROCESS FOR MULTIMETALS

TECHNICAL INFORMATION THEMOIL GRANODINE 112

Technical Process Bulletin

COLORMAX 9000C: Stannous Based Electrolytic Colouring Process

BONDERITE NT-1 Phosphate-free, Regulated Heavy Metal-Free Pre-treatment

Technical Process Bulletin. Alocrom 1000

Technical Process Bulletin

Technical Process Bulletin

Technical Process Bulletin

Technical Process Bulletin

Technical Process Bulletin

Technical Process Bulletin

Technical Process Bulletin

Technical Process Bulletin

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

NOTE: BONDERITE C-AK 4338C AERO should not be used on reactive alloys such as aluminum.

BONDERITE M-NT 7400 CR FREE CONVERSION COATING (Known as BONDERITE 7400)

Technical Process Bulletin BONDERITE C-AK 800 ALKALINE CLEANER (KNOWN AS PARCO CLEANER 800) Issued 5/31/ Introduction:

Technical Process Bulletin

Luster-On Products. Technical Data Sheet LUSTER-FOS 2900 CALCIUM MODIFIED, FINE GRAINED ZINC PHOSPHATE

Issued 5/30/2013. Bath Preparation per 100 Gallons: Aluminum Electrogalvanized Galvanized

TECHNICAL DATA SHEET GARDOBOND G 4040

HyProTec. Hexavalent free RoHS, ELV and WEEE compliant. HyPro System

TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate

DURNI-COAT DNC

Deruster 11 J Product Code: Revised Date: 01/26/2009. Deruster 11 J

Insta-Blak SS-370. Room Temperature Blackening Solution for Stainless Steel

HAVACOAT MG 15 CHROMATE PROCESS FOR MAGNESIUM

TECHNICAL BULLETIN IMMERSION SILVER - IS150

Black Magic Infusion Powder Product Code: Revised Date: 07/18/2016. Black Magic Infusion Powder

E-Chrome Ultra Yellow 600

Technical Process Bulletin

Issued 6/24/2013. Bath Preparation per 100 gallons:

Issued 5/31/2013. Applied by spray or immersion, this strongly alkaline treatment is particularly recommended for use ahead of BONDERITE processes.

PavCoTing. Chromium appearance and corrosion resistance Ease of plating bath control Wide current density range

CEE-BEE CLEANER A-7X7 by Cee-Bee

Laser ACB 50 Product Code: Revised Date: 03/17/2009. Laser ACB 50

PREPOSIT Etch 748. For PWB Metallization Applications. For use in the CIRCUPOSIT 3000 Process. Bath Make-up Metric (for 100 liters)

HAVALLOY Z-C ACID CHLORIDE ZINC / COBALT PROCESS

CEE-BEE CLEANER J-84A by Cee-Bee

Mi-Phos Z-10 Product Code: Revised Date: 9/12/2012. Mi-Phos Z-10

Technical Process Bulletin

Laser EX 50 Product Code: Revised Date: 03/17/2009. Laser EX 50

PRETREATMENT TECHNICAL DATA SHEET A REGENERABLE ACID PICKLE PRODUCT DESCRIPTION

Activated Black Magic Plus Product Code: Revised Date: 10/26/2016. Activated Black Magic Plus Black Oxide Finish for Steel

4831 S. Whipple Avenue Chicago IL Phone: Fax:

Lead-free electroless plating nickel bath for high wear and corrosion resistant applications

SurTec 650 chromital TCP

Black-Magic RT S 30 Product Code: Revised Date: 01/11/2013. Black-Magic RT S 30

SILVERON TM GT-101 Bright Silver Cyanide-Free Bright Electrolytic Silver For Electronic, Decorative and Industrial Finishing Applications

ALODINE 5923 is a chemical conversion process for aluminium and its alloys, completly free from hexavalent chromium

E-Brite 30/30. Non-Cyanide Alkaline Copper Plating

SurTec 650 chromital TCP

CIRCUPOSIT Neutralizer 3313 For PWB Metallization Applications

Material Safety Data Sheet

PALLAMET 500 Palladium-Nickel

RECOMMENDED APPLICATION PROCEDURE FOR SOLID FILM LUBRICANTS & COATINGS

Ultrex CAA Product Code: Revised Date: 10/09/2006. Ultrex CAA Heavy Duty Alkaline Product Derusting - Descaling - Activation

Tinmac Stannolyte Bright Acid Tin Solution

Technical Data Sheet. Physical Specifications

Safety Data Sheet. Power Steering Fluid (1L) Automotive transmission fluid. Gulf Western Oil Links Rd St Marys NSW 2760 Australia

MATERIAL SAFETY DATA SHEET NON-HAZARDOUS SUBSTANCE ACCORDING TO WORKSAFE AUSTRALIA

Safety Data Sheet Oven & Grill Cleaner 1. Identification

MATERIAL SAFETY DATA SHEET CR-7S

Lumina. Bright, leveled deposits in less time Excellent ductility Good chromium reception Very low additive consumption rate. Nickel Plating System

Luster-On Products. Technical Data Sheet LUSTER-ON CADMIUM SPECIAL

DRILLING AND TAPPING COMPOUND

Safety Data Sheet. Euro Energy (205L), (20L), (5L) Full synthetic premium engine oil. Gulf Western Oil

FEATURES AND BENEFITS

Alkzinc 818. Mirror bright finish Good zinc deposit distribution Very good adhesion and ductility Excellent chromate receptivity

Technical Data Sheet

4831 S. Whipple Avenue Chicago IL Phone: Fax:

Safety Data Sheet. Gulf Western Oil Links Rd St Marys NSW 2760 Australia. (02) (phone) (02) (fax) Not applicable

NB SEMIPLATE CU 200 Copper electroplating process

Red Insulating Varnish 4228 Technical Data Sheet 4228-Liquid

LOCTITE EF 9899CF AERO

Safety Data Sheet (205L), (20L) High pressure synthetic lubricant for gears. Gulf Western Oil Links Rd St Marys NSW 2760 Australia

Heresite P-413 TECHNICAL DATA SHEET. P-413 Typical Properties 1 mil DFT) Our 50 years of coating history speaks for itself.

MATERIAL SAFETY DATA SHEET

Red Insulating Varnish 4228 Technical Data Sheet 4228-Liquid

Material Safety Data Sheet

POSISTRIP EKC830. Will effectively remove hard to remove positive photoresist

Applications Core Stabilization Edge Close Out RTM Core Applications Filling Core in Closed Mold Operations Stiffening of Composite Structure

SAFETY DATA SHEET. Abbreviation

CIRCUPOSIT 71 Full Build Electroless Copper Nitrate Bath (Generic Concentrates) For Electronic Finishing Applications

ARALDITE AV 119 EPOXY ADHESIVE PASTE

LUXAPOOL CHLORINATED RUBBER POOL COATING

COPPER GLEAM RG 11 Acid Copper Plating Process

MATERIAL SAFETY DATA SHEET ALUMINIUM SULPHATE SOLUTION

MATERIAL SAFETY DATA SHEET DOC VERSION: 1 PROTO-PASTA AROMATIC COFFEE HIGH TEMPERATURE PLA PRINT DATE: 10/08/2015 REV DATE:

SAFETY DATA SHEET (SDS)

Material Safety Data Sheet

SUPER BEE 400TG-ML CLEANER by Cee-Bee

Ultrex EDM Product Code: Revised Date: 07/26/2006. Ultrex EDM Heavy Duty Alkaline Product Derusting - Descaling - Activation

SAFETY DATA SHEET. Supplier. Product Identification. Hazards Identification. Composition / Information on Ingredients. Date of Issue: November 2016

Material Safety Data Sheet

THE GLUE FACTORY, LLC An Ellsworth Adhesives Company 3430 W. Highview Drive, Appleton, WI MATERIAL SAFETY DATA SHEET HM-101-K

Radiator Maintenance

Transcription:

TECHNICAL BULLETIN 135-141 Canterbury Road, Kilsyth Victoria 3137 Phone : (613) 9728 7200 Fax : (613) 9761 7179 ALODINE 1200S A. SUMMARY 1. INTRODUCTION Alodine* 1200S is a powdered chemical, used for producing paint bonding, corrosion resisting coatings on aluminium and its alloys by either spray or dip processing. 2. MAKE UP AND OPERATION Alodine 1200S is usually made up at 7.5 kg per 1,000 litres of bath. The Alodine 1200S powder should be predissolved in a bucket of cold water before adding to the main tank and the tank contents should be thoroughly stirred or recirculated through the spray system. The same concentration of Alodine 1200S is normally used for both spray and immersion processes. The bath is operated at 24-30 C and controlled by ph and titration. 3. PROCESS SEQUENCE 1. Preclean. 2. Clean with Ridoline* cleaner. 3. Cold water rinse 4. Coat with Alodine 1200S 5. Cold water rinse 6. Passivation with Deoxylyte* Coatings are then usually dried and painted. 4. EQUIPMENT The tank and equipment for Alodine 1200S should be constructed from stainless steel; type 316 preferred for weldability. If necessary, heated tanks should be fitted with steam plate coils and side heating (for more even temperature distribution.) Detailed recommendations on equipment and specific process sequences are available from a Henkel** Technical Representative.

Alodine 1200S Page 2 B. TECHNICAL DETAILS 1. BATH MAKE UP AND CONTROL Make Up For each 1,000 litres of bath volume, add with stirring: Water Alodine 1200S 900 litres 7.5 kg The Alodine 1200S should be predissolved inwater before adding to the bath. Mix and make up to volume (1,000 litres) with more water. Control Points (for normal operation) Immersion Spray Contact Times 60-90 sec. 15-30 sec. Spray Pressure N/A 50-80 kpa Bath Pointage 5-7 ml 5-7 ml ph 1.3-1.8 1.3-1.8 Temperature 24-30 C 24-30 0 C See Section B3 for Test Methods 2. SURFACE PREPARATION The Alodine 1200S system requires a perfectly clean surface for uniform results. The work is usually cleaned with a Ridoline cleaner. Any corrosion products or heavy uneven oxide layer should be removed by immersion in a Henkel Deoxidiser or Aluminium Etchant. Your Henkel Technical Representative will recommend the required cleaning procedure for each installation. The Ridoline cleaner stages are usually followed by two 30 second or one 60 second unheated rinse. The rinse is constantly overflowed to prevent build up of contamination products.

Alodine 1200S Page 3 3. TESTING AND BATH MAINTENANCE General The Alodine 1200S bath is controlled by ph measurement and one titration. The pointage is determined regularly and determines the required amounts of Alodine 1200S to be added to replenish the bath. Bath Pointage 1. Standardisation of 0.1N Ferrous Ammonium Sulphate (Titrating Solution 31) (i) (ii) Pipette exactly 10.0 mls of 0.1N Potassium Dichromate Solution (Titrating Solution 30) into a flask. Add 30 ml Reagent Solution 44 (50% Sulphuric Acid). (iii) Add 4-8 drops of Ferroin Indicator (Indicator Solution 12). (iv) Titrate with 0.1N Ferrous Ammonium Sulphate (Titrating Solution 31) until the solution changes from green to blood red. Record the number of millilitres of Titrating Solution 31 added as A ml. 2. Bath Testing Standardisation factor (F) = 10.0 A (i) Pipette a 5.0 ml aliquot of bath into a flask. (ii) Add 20 ml of Reagent Solution 44. (iii) (iv) (vi) Add 4-8 drops of Indicator Solution 12 (Ferroin) and mix. Titrate with standardised Titrating Solution 31 (0.1N Ferrous Ammonium Sulphate) until solution changes from green to blood red. Record the number of millilitres of Titrating Solution added as B mls. Multiply no. mls. Titrating Solution 31 used B by Correction factor (F) determined above to calculate actual bath titration value.

Alodine 1200S Page 4 2. Bath Testing (continued) (vii) (viii) Record the total no. of corrected Titrating Solution 31 used as the Alodine titration. To increase Alodine titration by 1 ml, add 1.25 Kg. of Alodine 1200S per 1000 litres of bath volume (c) Bath ph (i) Standardise the ph meter with the correct buffer according to manufacturer s instructions. (ii) (iii) Dry electrodes and immerse in sample of Alodine 1200S bath. Take reading when meter stabilises. (iv) Remove electrodes, rinse with distilled water and store in the correct solution. To decrease ph, add Toner 6 at the rate of 1.25 litres per 1,000 of bath; allowing 15 minutes for bath to stabilise before rechecking. Under normal conditions, the addition of 500 ml of Toner 6 per 1-2 kg of Alodine 1200S added to maintain bath concentration will also maintain ph in the desired range. 4. OPERATIONAL RECOMMENDATIONS The initial charge and replenishment data contained herein are satisfactory for most installations. However, your Henkel Technical Representative may suggest a deviation from this data if indicated by local conditions. If the Alodine coating is powdery, the cause may be one or more of the following: - ph too low - Temperature and/or concentration too high for treatment time - Work improperly cleaned or rinsed - Alodine bath contaminated - analysis required

Alodine 1200S Page 5 4. OPERATIONAL RECOMMENDATIONS (c) If the coatings are uniform but iridescent the cause may be one or more of the following: - ph too high - Concentration too low - Bath temperature too low for the contact time used - Contact time too short - Reaction products in solution - analysis required (d) If the coatings look patchy the cause may be one or more of the following: - Cleaner bath exhausted - Incorrect cleaner used - More etching required 5. AFTER TREATMENT Cold Water Rinse After immersion in the Alodine 1200S bath, the work should be rinsed for a minimum of 30 seconds in cold water. This tank should have a continuous overflow to lessen build up of contaminants. Deoxylyte Passivation The work is then rinsed for 30 seconds with clean, salt free water containing Deoxylyte 41 (for maximum corrosion resistance.) This stage may be operated hot to facilitate drying, and in some cases may avoid the need for a dry off oven. (c) Drying The work should then be dried in an indirect fired oven or by other means which will not contaminate the coating with oil fumes or partially burnt gases. The temperature should not exceed 82 C. Solution trapped in cavities should be removed by suction, or with compressed air before drying. 6. PLANT MAINTENANCE Water rinses are ideally dumped each day and made up afresh. Local water authorities should be consulted as to the allowable levels of contaminants that can be discharged to sewer. Cleaning stages should be skimmed to keep the surface clean and the bath dumped when excessive soil accumulates in the bath.

Alodine 1200S Page 6 7. HANDLING PRECAUTIONS Alodine 1200S powder and baths are acidic, and poisonous. Fume or spray vapour from an Alodine bath is toxic. Alodine baths should be situated in a positively ventilated areas. If rags, paper or clothing contaminated with Alodine dry out, they constitute a fire hazard. Clothing should be promptly washed out and rags and paper should be disposed of in the wet state. Operators handling Alodine 1200S powder or liquid and Toner 6 should wear rubber gloves, respirators and eye protection. If Alodine 1200S powder or liquid or Toner 6 come into contact with the skin, immediately flush with water and seek medical attention. 8. SPECIFICATIONS Alodine 1200S conforms to MIL-C-5541E Class 1A and 3 coatings, Methods A, B & C application. 9. GENERAL (i) Electrical Resistance Alodine coatings are electrically conductive. The resistance of a coating depends upon its thickness and its age. The lowest resistance is obtained with the lightest coatings and when coatings are fresh (i.e. <12 hours old) deoxidised surfaces allow a more uniform deposition (and hence lower resistance) to be obtained. A typical figure for the resistance for a fresh coating with a weight around 500 mg/m 2 (45 mg/sq ft) would be 600 microhms. Conversely, the typical conductivity value is around 1,700 siemens. (ii) Coating Flexibility The flexibility of the conversion coating is equivalent to the base metal. (iii) Coating Thickness This usually ranges from 0.125-0.25 microns (0.005-0.1 thousandths of an inch.)

Alodine 1200S Page 7 9. GENERAL (iv) Solubility The coating is insoluble in alcohol, water, organic and petroleum solvents. It is soluble in strong acids or alkalis Coating Weights Optimum production coating weights are determined by service and product requirements. Typical prepaint coatings range from 100-800 mg/m 2 (10-75 mg/sq ft). 10. HENKEL PRODUCT REFERENCE Alodine 1200S Toner 6 * Registered Trade Mark of Henkel Corporation USA. ** Registered Trade Mark of Henkel Australia Pty Limited. DISCLAIMER Any information given is, to the best of our knowledge, the best currently available, with respect to our products and their use, but it is subject to revision as additional knowledge and experience is gained. Such information is offered as a guideline for experimentation only and is not to be construed as a representation that the material is suitable for any particular purpose or use. Customers are encouraged to make their own enquiries as to the material's characteristics and, where appropriate, to conduct their own tests in the specific context of the material's intended use. This information is not a license to operate under nor is it intended to suggest infringement of any patent. We guarantee a uniform quality standard for this product. The only conditions and warranties accepted by Henkel in relation to this product or process are those implied by either Commonwealth or State statutes. Ref.ALO1200S 16th October,1996