AWASHAFT DN400. Product and Installation Guide

Similar documents
Installation Overview

Construction Automotive Industry.

RAUCORD WEAVING MATERIAL PRODUCT LIST FOR 2010 / Construction Automotive Industry

RAUTITAN PEX PLUMBING SYSTEM. Secure. Easier. Faster.

Sewerage Code WSA Addendum PART 3 STANDARD DRAWINGS

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints

Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints Installation Manual

Sewerage Code WSA Addendum PART 4 - CONSTRUCTION

SECTION FACILITY SANITARY SEWERS

SANITARY WASTE AND VENT PIPING

Bridge Drainage Systems

Adoptable and Non-Adoptable Assemblies.

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

WSAA PRODUCT APPRAISAL CERTIFICATE

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

RAUPIANO PLUS ACOUSTIC PLUMBING AND DRAINAGE SYSTEM. Product. Scope. Building Regulations. Appraisal No. 809 [2013]

Wavin: Range 600 Inspection Chambers

TABLE OF CONTENTS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Rodding Eye Details. Inspection Chambers

Daytona Beach Pier Building Renovation Jun 2010

SECTION STORM SEWER COLLECTION SYSTEM

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe

SECTION (15150) - SANITARY WASTE AND VENT PIPING

Date: 13/04/2015 1:14:38 PM

Section 4 Service Lines

SECTION SANITARY SEWERAGE PART 1 GENERAL 1.01 RELATED DOCUMENTS

OSMADRAIN UNDERGROUND DRAINAGE SYSTEM OSMADRAIN UNIVERSAL GULLY SYSTEM

PRODUCT SPECIFICATIONS FOR PRODUCTS AND MATERIALS. Numerical Listing

(For compliance with the new sewers for adoption regulation or building regulations part H1)

Product and Installation Guide

h Installation Manual

HYDROTECH TM MS3 MULTI-LAYER PVC-U PIPE SYSTEMS SUITABLE FOR BUILDINGS, HOUSES AND CIVIL CONSTRUCTION PURPOSES.

RAUPIANO PLUS The versatile acoustic drainage and trade waste system Installer guide

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building.

FORM 1 S Design Certification List - Wastewater Agreements

Terrain HDPE. Product Guide

Installation and maintenance instructions for PLATIN and PLATIN XL Rainwater Underground Tank

4 ft. and 6 ft. Downstream Defender Handling and Installation Instructions

SECTION SANITARY UTILITY SEWERAGE PIPING

A. Gravity-Flow, Nonpressure, Drainage-Piping Pressure Rating: 10-foot head of water (30 kpa).

SPECIAL SPECIFICATION 5925 Polyvinyl Cloride (PVC) Sewer Pipe and Fittings

Manholes. ...a real breakthrough in sewer technology. Jeevan bhar ka saath... Unique features. Design Registered

Assembly and Installation Instructions Grease Separator KLsepa.pop

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

CENTRAL AXIS MAINTENANCE SHAFT VERSION 1.0

Althon slot channels Althon

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF ELECTRICAL CHAMBERS

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

T a b l e o f C o n t e n t s

Supplementary Manual to the WSAA Water Supply Code (WSA :3.1) Melbourne Retail Water Agencies Edition V2.0

Installation instructions and maintenance for the GRAF Optimax external commercial filter

APPENDIX B STANDARD CONSTRUCTION DRAWING NOTES

SECTION SANITARY SEWER SYSTEM

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

DRAFT. Draft Bill of Quantities. Drainage

Agrément Certificate 89/2206 website: Product Sheet 6

PLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780)

SECTION STORM DRAINAGE

SPECIAL SPECIFICATION 4425 Thermoplastic Pipe

Polysewer Gravity Sewer System SPECIFICATION

1. Required Minimum Flow:

7. Allowable Fittings.

SECTION 39 - MANHOLES TABLE OF CONTENTS

DUKE UNIVERSITY CONSTRUCTION STANDARDS

freestone eco Prestige & quality DIY vertical wall Large blocks - 10/m 2 Smooth surface finish No concrete footings

GRAVITY SEWERAGE CODE

SECTION FACILITY SANITARY SEWERS

SIROPLAST-K. Pipe system for civil engineering subsoil drainage inspection chambers and subsoil drainage pipes to DIN

REHAU WINDOW SYSTEMS QUALITY YOU CAN COUNT ON. German engineered to local sensibilities for over 60 years. Construction Automotive Industry

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

A reliable solution for ditching, underpassing and rainwater drainage

CONNECTION TO INSPECTION CHAMBERS PRAKTO

Storm Drainage Structures

DEPARTMENT OF TRANSPORTATION STATE OF GEORGIA SPECIAL PROVISION. Section 550 Storm Drain Pipe, Pipe-Arch Culverts, and Side Drain Pipe

The Akatherm Akavent System - Design guidelines

Drain DESIGN & INSTALLATION GUIDE 316L STAINLESS STEEL INDUSTRIAL FLOOR DRAINS & LINEAR DRAINAGE CHANNELS

SUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018

INSTALLATION. Step 6. Step 7. Step 8

SANITARY SEWERS. B. Construct or relocate building sanitary sewer services, stubs, and connections.

ARRANGE FOR INSPECTION FORTY-EIGHT HOURS IN ADVANCE

A. Piping materials shall bear label, stamp, or other markings of specified testing agency.

Maintenance Access Shafts

VALLECITOS WATER DISTRICT SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE

Magnetic drive pumps YMD series

CHAPTER 200 STORM SEWER CONSTRUCTION STANDARDS

SECTION PUBLIC WATER SERVICE CONNECTIONS

University of Delaware

CI/SfB (52.5) September 2005 Uniclass L7315. ACO EuroCover Stainless steel composite double sealed access covers

SECTION HYDRONIC PIPING

CITY OF FARGO SPECIFICATIONS SEWER AND WATER SERVICE CONNECTIONS

SECTION GRAVITY WASTEWATER LINES

SECTION 400 SANITARY SEWER SYSTEM

Gravity Sewerage Code of Australia WSA

Transcription:

AWASHAFT DN400 Product and Installation Guide

AWASHAFT DN400 Safety for generations The AWASHAFT DN400 is a cleaning, inspection and transfer chamber for installation in private or municipal sewerage or drainage systems. The AWASHAFT DN400 maintenance shaft is compatible to all smooth walled sewer pipes DN150 made of PVC, PP and PE that comply with standards AS/NZS 5065. The elastomeric `lip seal joint sealing system meets all the requirements of EN 681. The AWASHAFT DN400 maintenance shaft can be installed to a maximum depth of 4 meters and has a buoyancy safety with permissible groundwater level of 4 meters above invert level. The shaft assembly can withstand a wheel load of 10 tonnes when installed with a cover of load class D that distributes the load to the surrounding ground. The DN400 chamber base has a flat base. The push fit joint with lip seal can accommodate a 1 deflection in either direction. The chamber can be flexibly adjusted to suit local site conditions using an AWADUCT PP DN/OD 160 ball joint which allows a 7.5º adjustment in all directions. 2

Transport, Storage and Handling Secure loose components during transport to prevent them from moving. All materials should be suitably protected to prevent them from mechanical and/or chemical damage (e.g. oil). The socket area must also be protected from dirt. All pipes and fittings should be protected from direct sunlight during transport and storage. Quality and Certifications AWASHAFT DN400 is independently tested and locally approved by leading laboratories and authorities. Tests are carried out according to relevant standards including WSA137, WMTS509 and EN681. 3

Installation Procedure 1. Prepare bedding area for chamber base as per the site requirements and in accordance with local regulatory requirements. 2. Place AWASHAFT chamber base into the pipe trench. Ensure sockets align with connecting pipes. 3. Apply appropriate lubricant to DWV PVC-U reducer DN375/300 and insert into the chamber base. Align offset. 4. Apply appropriate lubricant to upstream and downstream connecting pipes. Ensure gaskets are undamaged, clean and correctly positioned before pushing the connecting pipes into the chamber base sockets. Refer to page 6 on how to accommodate different approach angles. 5. Cap unused inlet branches with plugs. The plugs should be secured in place as specified by the local regulator. Some methods include: - placing a bag of dry premix concrete or cement in front of the plug. - placing a wet concrete mix in front of the plug. - placing a metal or wooden stake/peg in front of the plug. bedding material/sand. Compact bedding material layer by layer to a minimum cover of 100mm above chamber base. 7. Insert ascending PVC-U riser pipe DN300 into the reducer socket. Backfill is to be placed in layers and compacted in accordance with the specifications. 8. Cut riser pipe between 200mm to 300mm below finished surface level and install PVC-U push-on cap DN300 or PVC-U solvent weld-on cap with screw lid DN300. 9. Place shroud (minimum 450mm) over the riser pipe. Install support frame and access cover in accordance with local regulatory requirements and complete backfill. 6. Ensure that the chamber is level and add fine Cohesionless (non-cohesive) soils or low cohesive soil types of maximum grain size of 16mm (eg stepped soil with fine grains, graded sand/gravel mixes, etc) can be used to backfill around the chamber components. 4

Installation Overview FSL Access Cover and Frame Class A, B or D Support system Redwood, Concrete, Galvanised Steel angles or Recycled plastic bearers Shroud minimum 450mm PVC-U Push on cap, or PVC-U Solvent weld on cap with screw cap DN300 PVC-U Riser pipe DN300 Cut to required length PVC-U Reducer DN375/300 Chamber base DN/OD 400 (DN375) Straight (GD) or junction (RML) Inlet Outlet Access Cover Access cover and support system are installed independently of the maintenance shaft and riser pipe. Select the access cover and support system based on the site specific requirements. Suitable load classes are: Load class A: areas accessible to pedestrian traffic including footpaths > concrete shaft cover with 400mm clear opening Load class B: areas accessible to vehicles including footpaths and light carriage ways > class B concrete shaft cover with 400mm clear opening Load class D: roadways, carriageways and areas subject to commercial vehicles up to 10 tonnes wheel load > class D ductile iron shaft cover with 400mm clear opening Install shroud pipe and surface fitting in accordance with WSA 02 standard drawing SEW 1317 and client and local regulatory requirements. The shroud may be PVC or PE material and shall be minimum 450mm in diameter. The support frames shall be placed on either side of the shroud and have to bear and sufficiently distribute the traffic loads into the surrounding ground. 5

Approach Angles Continuous adjustable approach angles between 90 and 180 : Install ball joint fitting on the inlet and/or the outlet chamber base sockets (arrow indicates direction of flow). Certain approach angles require additional PVC-U (long variable) bends 15 or 30. Ball joint AWADUCT PP ball joint 180 180-165 165-150 135 150-120 120-90 6

Product Range Chamber base straight (GD) 1 inlet, 1 outlet Material: PP-HM (High Modulus) DN Inlet/outlet DN/OD M Z N H1 H2 [kg/pc.] t175165 750350 400 160 74 383 189 146 356 3.0 Chamber base junction (RML) 3 inlets, 1 outlet Material: PP-HM (High Modulus) DN Inlet/outlet DN/OD M Z N H1 H2 [kg/pc.] t175167 750351 400 160 74 329 189 146 356 3.5 Ball joint AWADUCT PP ball joint Continuously adjustable up to +/-7.5 O horizontally or vertically with EPDM sealing ring (Safety-Lock) Material: RAU-PP 2300 Design DN/OD L Dmax t [kg./pc.] t176055 750353 Socket/spigot 160 207 210 101 1.21 PVC-U Reducer AWADUCT connecting reducer with lip sealing ring Material: RAU-PVC 1100 DN [d 1 /d 2 ] Z 1 * [kg/pc.] t171906 750352 375/300 155 5.7 PP Plug AWADUCT plug Material: RAU-PP 2300 DN/OD d 1 L [kg/pc.] t100918 750390 160 160 63 0.2 7

Reece. Works for you. Call 1800 032 566 or visit www.reece.com.au for your nearest Reece store. This document is protected by copyright. All rights based on this are reserved. No part of this publication may be translated, reproduced or transmitted in any form or by any similar means, electronic or mechanical, photocopying, recording or otherwise, or stored in a data retrieval system. Our verbal and written advice relating to technical applications is based on experience and is to the best of our knowledge correct but is given without obligation. The use of products in conditions that are beyond our control or for applications other than those specified releases us from any obligation in regard to claims made in respect of the products. We recommend that the suitability of any product for the intended application should be checked. Utilisation and processing of our products are beyond our control and are therefore exclusively your responsibility. In the event that a liability is nevertheless considered, any compensation will be limited to the value of the goods supplied by us and used by you. Our warranty assumes consistent quality of our products in accordance with our specification and in accordance with our general conditions of sale. Branches in Asia Pacific : SINGAPORE - Regional Office for Asia Pacific 1 King George s Avenue, Building, Singapore 208557 Tel: +65 6392-6006 Fax: +65 6392-6116 AUSTRALIA National Customer Service Centre Tel: 1300 768 033 GREATER CHINA Beijing Tel: +86 10 6428-2956 Chengdu Tel: +86 28 8628-3218 Guangzhou Tel: +86 20 8776-0343 / 3646 Hong Kong Tel: +852 2898-7080 Qingdao Tel: +86 532 8667-8190 Shenyang Tel: +86 24 2287-5807 Shanghai Tel: +86 21 6355-1155 Taicang Tel: +86 512 5337-2888 Taipei Tel: +886 2 8780-3899 Xi an Tel: +86 29 6859-7000 INDIA Bangalore Tel: +91 80 2222-0014 Mumbai Tel: +91 22 6148-5858 New Delhi Tel: +91 11 4848-5600 Pune Tel: + 91 21 3567-4301 / 4340 INDONESIA Jakarta Tel: +62 21 4587 1030 JAPAN Tokyo Tel: +81-3-3292-8337 NEW ZEALAND Auckland Tel: +64 9 2722-264 PHILIPPINES Manila Tel: +63 2 654-5120 THAILAND Bangkok Tel: +66 2763-5100 VIETNAM Ho Chi Minh City Tel: +84 8 3823-3030 www.rehau.com Errors and changes are to be expected ANZ001 WT 11.2016 Reece : 2131477