system Reduces operating costs and CO 2 emissions by as much as 50% [ We document the difference ]

Similar documents
Energy efficiency and flexibility

A new dimension of flexibility

Defining Network efficiency. Jørgen Ægidius, VP Sales EHP conference, Tallinn April 2015

PRE-INSULATED PIPE PRODUCT GUIDE

Radiator Heating. Pre-Insulated Pipe. Plumbing. Underfloor Heating. Pre-Insulated Pipe Product Guide. Application and System Overview

logstor Onshore Crossing frontiers with pre-insulation

PREINSULATED PIPE SYSTEMS FOR HOT WATER NETWORKS

Pre-insulated pipes for industrial applications

LOGSTOR VALUE Proposition for DC

FLEXIBLE PREINSULATED PIPES

Pre-insulated pipes for industrial applications

FlexPipe. Pre-Insulated Flexible Pipe Systems for District Heating & Cooling

KELIT PEX 95R-10 KELIT PEX 115R-16 %URFKXUH

A New Low-Temperature District Heating System for Low-Energy Buildings

TRAINING AND CERTIFICATION

INDEX. General information. Technology, quality and environment. Single pipes. Double pipes. Special pipes. Joints. Monitoring system.

CALPEX Low Temperature System

Design with TwinPipes. Version

Abstract. Development of new generation polyols for semi-flexible foam systems for the production of flexible polyurethane pre-insulated pipes

PRE-INSULATED PIPE OVERVIEW. Easy to install Cost-effective Energy-saving. Pre-Insulated Pipe Systems

INSULATION AGING & GREEN FOAM

DISTRICT HEATING & HEAT NETWORKS PRESENTATION

Pipes APPLICATIONS PIPES AND FITTINGS COMPATIBILITY. A full range for the perfect installation. Comap provides a wide choice to complete

System solutions from a single source Systems for producing flexible polyurethane-insulated pipes

CHRYSO Flexo. An Innovative System for Precast Insulated Concrete Sandwich Panel. Products for the Reinforced Concrete Construction Industry

PE-XA PIPE SYSTEM. An efficient, flexible and reliable pre-insulated PE-Xa pipe system for heating applications

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

SSAB water mains. A reliable and economically advantageous solution for water supply.

Global ambitions for the environment and people

Phenolic Foam (PF) Insulation

PREMANT. Pre-insulated steel pipe system

Creating Optimal LNG Storage Solutions. 40 in detail

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

ULTIMATE Tech Wired Mats High performance for high temperatures

NEW! THE FLEXIBLE PROFESSIONAL INSULATION WITH REVOLUTIONARY CHARACTERISTICS. even easier to use

Underground System. Description

9.0. Table of contents. CALCOPPER - District heating pipe CCO. 9.0 Table of contents. 9.1 System description

Installation Instructions and Information Pack

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

FLEXWELL FHK. Flexible district heating pipe

Contents. 3. Overview Pipe. 8. Fittings. 9. Features & benefits Installation considerations. 16. Jointing instructions

Solutions for industrial pipe work insulation

Pre-Insulated Pipe Technical Guide RHI COMPLIANT PRE-INSULATED PIPE. Installation & Technical Information. Radiator Heating. Pre-Insulated Pipe

Uponor Pre-insulated pipes even better with improved insulation. Up to 12 % better insulation. New insulation foam

FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457)

FLEXWELL LNG All-in-One. Flexible pipe systems for LNG fuel stations

WATER AND SEWAGE SYSTEMS

HEAT NETWORK SOLUTIONS. REHAU. Your district heating partner

1000Introduction This specification details the design, materials, installation and commissioning standards for Underfloor Heating Systems.

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved

QUALITY CONTROL OF JOINT INSTALLATION IN PRE-INSULATED PIPE SYSTEMS

THE COMPLETE POLYETHYLENE INSULATION PACKAGE FOR EFFECTIVE ENERGY SAVING AND ACOUSTIC PROTECTION

Project Report. KPPS - pipe installation - Bree (Belgium)

EI INSTALLATION OF UNDERGROUND CABLES - LV TO 132KV

System Description BRF. Drinking water pipes. BRUGG drinking water pipe, Type BRF made of stainless steel V2A / V4A. Construction: 07.

THE PROFESSIONAL HIGH PERFORMANCE INSULATION FOR LONG TERM ENERGY SAVING TRUSTED SINCE 40 YEARS

Insultherm TECHNICAL SUBMISSION DYNATHERM PP-RCT

Drinking water and sewage pipes. System Description. BRUGG drinking water and sewage pipe, Type BPE made of polyethylene

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

COMPLIANT EUROPEAN STANDARD WITH THE NEW EN Heating / Air Conditioning Pulsar P.FE Radiant Panel ENVIRONMENTAL COMFORT

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

INDEX. page. page. page TALOS ECUTHERM SOLAR COPPER TUBES DOMA COPPER STRIPS TALOS SOLAR PLUS COPPER TUBES

The future-proof solution for pitched roofs. L-Ments Self-supporting, insulating roofing elements

FLAT WOVEN STEEL SLINGS

Renewable energies Concepts Heat exchanger solutions. Experts for energy recovery. We make waste-heat to your profit

CRYOGENIC SUPPORTS INTRODUCTION

Newport City Council Bettws High School Underfloor Heating Specification CONTRACT 2

ENERGY EFFICIENT ELECTRICAL HEATING OF SCR LINES

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

UEE11 Electrotechnology. Training Package SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

Quality NBR Insulation

PRE-INSULATED PIPE TECHNICAL GUIDE

CRYOGENIC SUPPORTS INTRODUCTION

Energy Code Math for Commercial Walls: How polyiso continuous insulation can help

Isolation vs Insulation:

KNOW-HOW. Quality characteristics of technical insulation materials: Fast and reliable installation is crucial

F Ü R D I E ZU K U N FT G E DAC HT. Flat roof vents. Soil vent pipes Refurbishment vents Cold roof vents

Pipe Supports Comparison

Bosch 4000S Internal Room-sealed continuous flow water heater and flue components

TECHWRAP2 AND TECHTUBE Acoustic solutions for pipework and equipment

armaflex cryogenic systems

THE HIGH PERFORMANCE INSULATION FOR AIR CONDITIONING, HEATING, REFRIGERATION AND PLUMBING

BALL VALVES RS-WOG type

InoxSabiana 25 Flues. Stainless Steel Double Wall

H. Underground Transmission System Design

INDEX. page. page. page TALOS ECUTHERM SOLAR COPPER TUBES DOMA COPPER STRIPS TALOS SOLAR PLUS COPPER TUBES

NPS/002/023 Technical Specification for 132kV Power Cables.

C Si Mn Ni Cr Mo Nb N V P S max 0.75 max max 0.03 max

STERIFLANGE. Welding Guide. Welding the flange into position. This welding guide should be read carefully before unpacking the Steriflange. Order No.

Pumps in district heating network

August 2008: Issue 1. Non - Residential New Build Built - up Metal Walls

LINE SETS. Made in Italy

Pulsar. The panels feature a very interesting construction: modern welding units, Radiant Panels

The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.

GEOTHERMAL OVERVIEW. Presented by John Cole East Coast Account Rep. for RENEWABLE ENERGY. Construction Automotive Industry

Specialist pipework for safe fuel transfer

ORDINANCE ON TECHNICAL REQUIREMENTS FOR CABLE DUCTS

Mass Transport of Cell Gases in Carbon Dioxide Blown PET (Polyethylene Terephthalate) Foam Insulation

Marine & Offshore Fire Divisions

Transcription:

system Reduces operating costs and CO 2 emissions by as much as 5% [ We document the difference ]

system when energy efficiency is in focus Absolute minimum of heat loss ROI increases as world energy prices rise Lowest possible environmental impact TwinPipe district heating systems provide you with significant reductions in CO 2 emissions as well as big savings on purchase costs, civil works and operating costs compared to single pipe systems. It is possible to reduce both operating costs and CO 2 emissions by as much as 5%. And TwinPipes fitted with a provide even greater savings. Significant savings on operating costs Significant savings on civil works costs Easier planning and installation Lower costs for post-installation civil engineering Insulation that ensures consistently high heat retention throughout the service life of the pipe Fewer components and joints needed All fittings and joints included as an integral part of the system Diffusion barrier on pipes with outer casings up to Ø 315, for extra efficiency casing (HDPE) Diffusion barrier (aluminium foil) Polyurethane foam (PUR) insulation Alarm wires (copper) Service pipe (steel or copper) The LOGSTOR TwinPipe system places both forward and return flow pipes within one single outer casing, encapsulated in the same kind of highly effective polyurethane foam insulation as used in LOGSTOR pre-insulated single pipes. And to maintain its insulation properties unchanged, TwinPipe is available with a on all sizes up to outer casing Ø 315. Minimise heat loss The special TwinPipe design means the heat loss from a TwinPipe system is less than when using a single pipe solution. When also fitted with a, heat loss is kept consistently low throughout the entire service life of the pipe. Figure 1 below provides an example of the heat loss over a 3-year period, for lengths of single pipe and TwinPipe of comparable dimensions. The distance between the performance curves clearly shows that use of TwinPipe with or without a diffusion barrier significantly reduces heat loss. Figure 1 : Example of annual heat loss, with and without Parameters: Single pipe Ø 4/11 TwinPipe Ø 4/16 Service pipe: steel Insulation: Pipe length: 1 m trench Temperature, flow/return pipe: 12/7 C Temperature, ambient: 8 C Operating period: 3 years The advantage LOGSTOR TwinPipe fitted with a diffusion barrier has thermal conductivity levels of lambda 24 or better. The keeps the foam propellant gases inside the insulation, and prevents any nitrogen or oxygen from the soil or air penetrating into it. This means the pipe retains the same low lambda value throughout its entire service life. The provides greatest benefits for district heating pipes with smaller diameters, where the relative heat loss is greatest. This is why TwinPipe is available with a on pipes with the smallest diameters. Figure 2 below shows the total heat loss for single pipe and TwinPipe of different dimensions, with and without diffusion barrier. The calculations are based on average insulation performance over the duration of a 3-year service life. Figure 2 : Heat loss from single pipe and TwinPipe of different dimensions Parameters: Service pipe: steel Insulation: Pipe length: 1 m trench Soil cover:.6 m Thermal conductivity: soil 1.6 W/ mk, service pipe 6 W/mK Distance between single pipe:.15 m Temperature, flow/return pipe: 12/7 C Temperature, ambient: 8 C Operating period: 3 years The advantages of a TwinPipe system differ from one project to the next, and individual assessments are crucial. For example, the two-in-one TwinPipe configuration results in special requirements when laying the pipe, and is best suited to relatively flat terrain. For some projects, the initial investment is higher than for single pipe systems. However, this is soon outweighed by the savings on subsequent operating costs. Any decision about installing a TwinPipe system should therefore be based on careful consideration of all the parameters involved. One way of doing this is via the calculation feature available at www.logstor.com 45 4 35 Single pipe Single pipe with barrier TwinPipe TwinPipe with barrier 9 8 7 6 Single pipe Single pipe with barrier TwinPipe TwinPipe with barrier Heat loss (W/m) 3 25 2 15 1 1 2 3 Service life, in years Heat loss (W/m) 5 4 3 2 1 pipe, nominal diameter

Greater reliability and savings on civil works Save on civil works TwinPipe systems are particularly advantageous in projects where only limited space is available. Trenches can be kept narrower and don t have to be as deep as for single pipe systems. This is because the branch pipes are installed at the same level as the main TwinPipe run. The benefits include substantial savings on installation costs. This is particularly important in locations that are paved over. Fewer joints, greater dependability and lower installation costs A TwinPipe system involves only half as many joints as a comparable single pipe system. This means fewer components and results in lower installation costs as well as significantly cutting down on any likelihood of operating interruptions during the service life of the system. This, combined with the benefits of the well-known LOGSTOR joint systems, which eliminate the use of pre-insulated branch joints, results in further savings and greater operational reliability throughout the system. Single pipe system Trench TwinPipe system Single pipe Single pipe system with pre-insulated branch joints 1 welds 1 joints Single pipe system with welded, shrinkable or steel branch joints 1 welds 4 joints TwinPipe system with pre-insulated branch joints 6 welds 3 joints TwinPipe system with welded, shrinkable or steel branch joints 2 4 welds 1 joint TwinPipe LOGSTOR TwinPipe is the most efficient solution available for small and mediumscale transmission and distribution piping. The system includes components that ensure cost-effective installation, including standard joints, bends and transitions between lengths of single pipe and TwinPipe. To ensure the necessary stability, the two service pipes are locked together using special fixing bars placed at the end of all straight sections. This limits any expansion that might take place where the laid pipe changes direction, and helps do away with any need for special sections to absorb expansion and reduce stress and tension in the pipe. More detailed information is available in the LOGSTOR manual at www.logstor.com.

Service life costs and CO 2 emissions both reduced LOGSTOR has more than 2 years of experience in the development, manufacture and installation of pre-insulated twin pipes. The sum total of all this practical experience has been integrated into the LOGSTOR TwinPipe system of today. The results add up to significant advantages and benefits both financial and environmental. Lowest possible service life costs Calculations of the service life costs for district heating systems clearly show that the largest single cost stems from heat loss. This makes it a good investment to prevent this expensive heat loss from occurring. As the example shown here indicates, a TwinPipe system whether fitted with a or not is an exceptionally good investment, provided the installation parameters are appropriate. Lower energy loss, less environmental impact The fundamental advantages of using district heating systems responsible use of energy and low environmental impact are now high on many political agendas. LOGSTOR TwinPipe systems provide exceptional levels of energy efficiency, enabling you to cut the CO 2 emissions from your district heating system to the absolute minimum and make a visible contribution to reducing the climate problems that stem from our energy consumption. Components Pipes Straight pipes Joints Weldable Curved pipes Technical data TwinPipe Service pipe * Insulation Diffusion barrier casing Alarm wires Guaranteed insulation performance with Guaranteed insulation performance without Continuous operating parameters Jointing method Hot tapping possible Longitudinal welded steel pipe, P235TR1, P235TR2 according to EN1217-1, or P235GH according to EN 1217-2 Polyurethane foam (PUR), using cyclopentane as blowing agent Aluminium foil Optional up to Ø 114.3-114.3/315 High-density polyethylene (HDPE) Copper λ.24 W/mK λ.27 W/mK 3 years at 14 C and 25 bar Gas or TIG welding Yes Bends pipe casing 5 4 3 2 15 Nominal diameter diameter Wall thickness diameter, diameter, Wall thickness Lengths available 2 26.9 2.6 125 3. 12 1 2 1 tons CO2 1 5 Branches 2 26.9 2.6 14 3. 12 25 33.7 2.6 14 3. 12 25 33.7 2.6 16 3. 12 32 42.4 2.6 16 3. 12 32 42.4 2.6 18 3. 12 4 48.3 2.6 16 3. 12 4 48.3 2.6 18 3. 12 Purchase cost of pipes Heat losses Civil works Maintenance Pumping costs Assumptions for calculations: Heat effect of the system: 4 MW Temperature, flow/return: 12/7 C Pump energy: 1% of heat supply Energy source: natural gas Energy price: EUR.5/kW Price of electricity: EUR.1/ kwh Effective interest rate: 4% Service life: 3 years The pipe system includes: 2 x 1 m DN 15 2 x 1 m DN 1 2 x 2 m DN 8 2 x 5 m DN 4, straight pipes (5 consumers, 25 kw each) 2 x 5 m Ø 2 AluFlex/Flex (2 consumers, 1 kw each) Weldable Transition pipes 5 6.3 2.9 2 3.2 12 5 6.3 2.9 225 3.4 12 65 76.1 2.9 225 3.5 12 65 76.1 2.9 25 3.6 12 8 88.9 3.2 25 3.6 12 8 88.9 3.2 28 3.9 12 1 114.3 3.6 315 4.1 12 & 16 1 114.3 3.6 355 4.5 12 & 16 Type of pipe (dimensions) A. TwinPipe with B. TwinPipe without C. Single pipe with D. Single pipe without Heat retention (W/mK) Heat loss (W/m) DN 4/16.24 11.7 18.8 DN 4/16.27 14.3 22.9 DN 4/125.24 17.1 27.6 DN 4/125.27 22. 35.5 CO 2 emissions with natural gas (kg/metre/year) This table shows calculations of the annual heat loss and CO 2 emissions for a 1-metre length of LOGSTOR pipe with insulation, at operating temperatures of 12 C and 7 C on the flow/return pipes, respectively. A comparison between the values in installation types A and D represents a saving of more than 47%. Reductions Valves Venting Isolation 125 139.7 3.6 4 4.8 12 & 16 125 139.7 3.6 45 5.2 12 & 16 15 168.3 4. 45 5.2 12 & 16 15 168.3 4. 5 5.6 12 & 16 2 219.1 4.5 56 6. 12 & 16 2 219.1 4.5 63 6.6 12 & 16 * TwinPipes are also available with service pipes made of hard copper. The LOGSTOR FlexPipe range also includes TwinPipes in which the service pipes are made of soft copper, alu/pex or PEX. LOGSTOR TwinPipes meet or exceed the requirements prescribed in EN 15698-1.

pindpromotor.dk 1799 [ We document the difference ] LOGSTOR A/S Danmarksvej 11 DK-967 Løgstør Tel. +45 9966 1 Fax +45 9966 118 logstor@logstor.com www.logstor.com