The Velaphone range. Under floor sound insulation for impact noise reduction. Velaphone Fibre 22. Velaphone Confort. Velafibre Eco

Similar documents
June Residential Refurbishment Separating floors

Specialists in Acoustic Flooring and House to Flat Conversions

June Non - Residential Refurbishment Separating floors

SubPrimo. subprimo. Acoustic insulation for timber & laminate flooring. Uniclass L5395:N372 EPIC E485:Y45. CI/SfB (43) T (P2)

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

Adjustable decking pedestals. Technical documentation

self-adhesive overlapping selvage

September Saddle Flooring Systems

ELASTICALLY SEPARATED FLOOR

CONCRETE SCREEDS, INTERIOR FLOORING AND WALL COVERINGS. BME Lepel, Adrienn PhD

Specialist products. Proven expertise. Acoustic flooring systems to meet the 2010 Scottish Standards - Section 5

CONSTRUCTION TROSIL - TROSIL TECH SUPERIOR SOUND PROOFING

Acoustic Cradle Levelling System

April Section 4.3. Separating Floors

T65 Impact Panels Floor System

TROCELLEN TROSIL, TROSIL TECH

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

FERMACELL DRY FLOORING ELEMENTS: IMPROVED LIVING CONDITIONS THROUGH BETTER ACOUSTIC AND THERMAL INSULATION. Dry Lining

NOMA Parkett Insulation

NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. Date of update May 30, 2018 Valid until May 29, 2023 HYBRIS

Contract18. Vitrified paving FLAT ROOF BALCONY ROOF TERRACE DISPLAY AREA

Technical Manual - Section 7 Lytag LWA Roof and Floor Screeds

CONSTRUCTION TROSIL - TROSIL TECH SUPERIOR SOUND PROOFING

TECSOUND ACOUSTIC INSULATION

PRODUCT CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Please Note: PhoneStar was previously branded as Phonewell

matteco CONSTRUCTION sound insulation products

SIDERISE CW range: AB & CVB/C acoustic upgrades for curtain walling

CERTIFICATE No VTT-C Date of issue

GLASS FIBRE MESH FABRICS. Stronger ideas for a sustainable world ETICS. Marble slab reinforcement. Lightweight construction boards reinforcement

Floor Insulation Underlayment Section Sound Control Matting

ENKASONIC FLOOR UNDERLAYMENT 9110

SOLUTIONS FOR TIMBER STRUCTURES ACOUSTIC INSULATION

tra-load Damp Proof Courses Product and Systems Overview

Installation over acoustic underlays

Sopro FDP 558 tile insulation board

SECTION 4.2 RIW SCREEDSAFE

SOUND INSULATION TESTING SITE READINESS CHECKLIST

Specification for Solid Timber Flooring Installation, Sanding and Coating

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

RENOVATIONS APPLICATION

D R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to PROTECTO WRAP COMPANY. Series/Model: Whisper Mat CS

ACOUSTIC INSULATION DIRECTLY UNDER FLOOR COVERINGS made from recycled rubber

Part E robustdetails. robustdetails. January 2018 Update Pack

September Reflex Bearers

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

3 in 1 Accoustical Underlay

APPLICATION PROCESS THE APPPROVAL PROCESS

Contents P/ 3. Ensuring Optimal Results P/ 4. Roof Insulation SF40 P/ 5. Roof Insulation Over Rafter Application P/ 6

Sealing and decoupling. Things to know and technology

NOMA Parkett. Engineering your security.

SIDERISE CW range: AB & CVB/C acoustic upgrades for curtain walling

Suspended timber upper floors

APPLICATIONS AND FUNCTION:

DURABASE. Systems for decoupling, sealing, drainage, sound and heat insulation. Systematic underlays. WP page 4/5. CI++ page 2/3. DD page 6.

Channel Drain Shower Base. Aqua Line pro. Installation Instructions

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

SIDERISE CBX flexible acoustic barriers for suspended ceilings

WATERPROOFING OF AN ACCESSIBLE FLAT ROOF WITH A POLYURETHANE LIQUID MEMBRANE AND TILING

imperbox Waterproofing imperbox Waterproofing Recommended use: Features: Materials: Coverage: Angles and waterproof bands: Substrates: Packaging

Footfall sound dampening system for wood flooring

Mapesonic CR Mapesilent

Regupol CONSTRUCTION. Regupol BA. Heavy duty screed isolation. Regupol BA. Excellent impact performance.

Selecting floors and ceilings

SECTION GYPSUM BOARD

EXP. Tilux-Line 4-6 DURABASE WP 7. Tilux Quick finder 11

The Freudenberg Politex Group

DIATHONITE SCREED Thermal, breathable and lightened screed

REOXTHENE TECHNOLOGY BITULIGHT LINE -5 C WATERPROOFING MEMBRANE WITH REVOLUTIONARY TECHNOLOGY

Leaving Certificate Revision Notes. Airtightness. Potential air leakage paths (the numbered points in section 2.1 give a description for

ECO-FRIENDLY, WATERPROOFING SYSTEM

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

Flooring and Acoustic Damping Sikafloor Marine

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

PERFORMANCE FLOORING UNDERLAY

Gruppo Polymax. Acoustic Insulation Technology. Product Catalogue We create silence

CI/SfB l l l Ym1 l (M2) l July Superior 4 in 1 insulation TIMBER FRAME SOLUTIONS GUIDE

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

Approved Document E Technical Design Report

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

Specification for Engineered, Laminate and Bamboo Installation

ONDULINE MINI 18. The stylish Do it Once roofing upgrade for your garden buildings.

LEWIS Dovetailed sheeting. Dovetailed Sheeting

Introduction. Contents

1.0 INTRODUCTION BUILDING REGULATIONS SOUND INSULATION REQUIREMENTS TEST PROCEDURE AND ANALYSIS...3

ACOUSTIC INSULATION SYSTEMS FOR FLOORS AND WALLS

ACOUSTIC SYSTEMS PROFLOOR. effective solutions for impact and airborne noise INNOVATION BUILT ON EXPERIENCE

Aging and temperature dependency of acoustic PVC floor covering under French certification NF UPEC.A+

J41 Reinforced bitumen membrane roof coverings

June Residential Refurbishment Separating walls

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

ACOUSTIC INSULATION DIRECTLY UNDER FLOOR COVERINGS made from recycled elastic materials

REGUPOL ACOUSTIC UNDERLAY COLLECTION SOUNDPROOFING SCREED AND TILED FLOORS

SIDERISE SC cavity barriers & fire stops for suspended ceilings

REOXTHENE TECHNOLOGY EASY LIFT PROFESSIONAL LINE -10 C WATERPROOFING MEMBRANE WITH REVOLUTIONARY TECHNOLOGY WALL-FLOOR JUNCTION MEMBRANE

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

RENOVATIONS APPLICATION FORM

Transcription:

The range Certification Certification Confort Impact noise reduction of up to 22 db Velafibre Eco Under floor sound insulation for impact noise reduction

Acoustic treatment for impact noise: a legal obligation Neighbourhood noise caused by foot, steps, impact, or moving and dropping objects on the floor constitute a considerable source of annoyance, and is the reason for numerous court proceedings between neighbours and/or promoters or builders. In order to ageing provision, and set permissible limits and take new construction methods into account,, a new acoustic regulation, the NRA was decreed in France in October 1994. It applies to new construction that have building permits lodged after 1st January 1996. In addition to provisions for protection from ambient noise, the permissible level for impact noise was lowered from 70 db(a) to 65 db(a). Two implementation Orders issued on 30 th June 1999 and implemented on 1st January 2000 apply new changes to the units and the indices used as well as to permissible noise levels. The product performance assessment index is based on laborhtory result calculation. The weighted impact noise level reduction ( Lw) is stated in db. The weighted pressure for the standardised impact noise (L'nT,w) is now set at 58 db. These provisions now apply to any locale, with the exception of : - Balconies or recessed balconies not located above a main room, - Communal stairwells where there is a lift, - Technical facilities. To summarise a performance obligation should be achieved, whether within a block of flats or a grouping of single family dwellings. The impact noise efficiency index Lw Lw is stated in db. The higher this value is, the better the acoustic performance. This value is determined during adverse standardised tests. An acoustic underlay is placed on 14 cm concrete slab, then recieves a 4 cm sreed. This index is used to estimate in situ performance characteristic depending on the structure s construction and associated coating materials. It is this index which characterises the performance of our acoustic underlays indicated in this document. Acoustic insulation for airborne noise Working on the same principle as acoustic insulation for impact noise, for laboratory performance and in situ measuring indices, we have a weighted attenuation index R w (C,Ctr), stated in db. It relates to acoustic insulation qualities of a wall.

The underlays used in response to these requirements Impact noise is transmitted by a building s structure. To avoid the transmission of noise, use a floating floor principle, by fitting a Vélaphone range separation underlay in-between the building s structure (slab) and the support screed. The thickness of the concrete slab also contributes towards improving the acoustic insulation. One cm of concrete is considered to provide a gain of almost 1 db for the Lw. Noise follows a logarithmic law and a gain of 3 db indicates that you divided the sound intensity of noise transmission by 2. Presentation The range consists of 3 products: - - - Velafibre Eco The range can be laid under parquet or under a floating screed. and have CSTBat certification and are registered on the Cerqual list. CSTBat Certification CSTBat certification drawn up and issued by the CSTB (Building Scientific and Technical Centre) certifies : - Compliance of the product with Standard Technical Document DTU 52.1, - Compliance with a reference document common to the whole product family, - Performance characteristic defined by a value or classification. Through an independent, impartial and competent body that verifies the compliance and effectiveness of testing carried out by the manufacturer product certification provides the user with : - Consistency product manufactured and its performance, - The certainty that a product is suitable for its purpose, - Reduction of acceptance inspections, - Traceability to facilitate claim. This quality label forms a determined and qualitative approach by the builder of new housing, elevating their standing and promotion of construction work to customers. Henceforth, only certified underlays are featured on the Cerqual list run by the Qualitel association. The Qualitel (LQ) label and the Acoustic (LQCA) label Twenty years ago, in order to promote construction solutions that improve acoustic comfort, subject to the requirements of the Qualitel association, a quality label was created. One of the 7 Qualitel criteria specifically relates to the treatment of noise emitted inside a building. and underlay form part of the list of products that can benefit from Cerqual marking, guaranteeing the efficiency level assigned by Qualitel. Since 1991 and after obtaining the Qualitel label (LQ), the Qualitel association has been able to assign the Qualitel Acoustic Label (LQCA). The gain is 3 or 6 db respectively in relation to acoustic regulations.

Acoustic performance characteristics under screed With Lw of 22 db, the Vélaphone offers unsurpassed performance. Velafibre Eco Noise reduction Lw 22 db 19 db(*) 20 db(*) Test report CSTB AC 04-038 CTBA 00/PC/ PHY/1034/614 CSTB AC 05-196 Classification SC1 a4 A - SC1 b3 A SC1 a2 A SC1 b3 A Rw 58 (-2 ; -8) 59 (-3 ; -8) 59 (-4 ; -10) CSTBat Certification 03a-02 03a-01 non (*) Vélaphone achieved an Lw value of 20 db under 47 mm of roof, wall and floor insulation (CTBA Report 05/CTBA-IBC/PHY/3173-B and its classification became SC1 b2 A Ch. NRA 2000/LQ/LQCA* Compliance 14 cm slab (1) Velafibre Eco 15 cm slab NRA 2000 Qualitel label 16 cm slab 18 cm slab Qualitel label NRA 2000 20 cm slab 22 cm slab Qualitel label Acoustic (*) Table drawn up based on theoretical hypotheses and assessments only as a function of Lw and the thickness of the concrete slab. (1) Reference concrete slab. Standard NF P 61-203 This standard, which is common to both DTU 26.2 and DTU 52.1, also defines implementation of underlays. It defines basic characteristics: SC (1 or 2) a or b (1 to 4) and specific characteristics: A Ch. Laying conditions : SC1: Enables direct laying of sealed tiling (with non-reinforced laying mortar with a nominal thickness of 6 cm or reinforced laying mortar that is 5 cm thick) SC2: Laying of a 6 cm underlay Permissible operating load : a : Operating load of 500 kg/m² relating to use in offices, classrooms, foyers, etc. b : Operating load of 200 kg/m² relating to use in housing. 1 à 4 : Index used in the case of 2 acoustic or thermal underlays being superimposed (see NF P 61-203 section 7.2). A : An impact noise acoustic underlay. Ch : Indicates that the underlay is compatible with heated floors. Markings example : SC1 a2 A Ch Acoustic underlay compatible with a class SC1 heated floor with an operating load of up to 500 kg/m².

Les performances Acoustic acoustiques performance sous characteristics parquet under parquet Velafibre Eco Noise reduction Lw 21 db 20 db 21 db Test report Composition CTBA 06/CTBA-IBC/ PHY/11 Non-woven polyester on a bitumen support CTBA 99/PC/ PHY/999/602.595 Non-woven polyester on a bitumen support CTBA 06/CTBA-IBC/ PHY/218 Non-woven polyester Thickness 3,3 mm 2,5 mm 2,8 mm Dimensions 20 x 1,07 m (20 m² effective) 20 x 1,07 m (20 m² effective) 60 x 1,20 m (72 m² effective) Weight of the roll env 13 kg env 13,5 kg env 22 kg Quantity per pallet 16 rlx ( 320 m²) 25 rlx (500 m²) 8 rlx (576 m²) Heat resistance 0,100 m². K/W 0,075 m². K/W 0,100 m². K/W Selection guide Velafibre Eco Solution Optimal High-performance Economic SC1 Classification Yes Yes Yes Acoustic performance **** *** *** Speed of laying **** **** *** Traffic flow resistance **** *** ** Tear strength **** *** *** CSTBat certified product Yes Yes No Advantages common to the whole range - Long experience, millions of m² of references. - Comprehensive range with the most recognised product on the market. - Stable acoustic performance over time. - SC1 classification for implementation whatever the type of laying. - Compatible with floating parquet. - Resistance to surfacing and tearing - Integrated cover strip to prevent grout penetration and enable coverage without excess thickness. - The products are rolled in the laying direction. - A large range of edge sealant tape.

Edge sealant tapes for achieving separation Standard NF P 61-203 (part common to DTU 26.2 & DTU 52.1) stipulates that the separation tapes must exceed the finished floor surface area by at least 2 cm, including the coating. It is recommended that you avoid any possibility of allowing grout penetration by applying adhesive tape. Separation can be achieved by raising acoustic insulation underlay rolls up and onto vertical walls around rooming perimiter (recommended with Vélaphone ). It is also possible to apply separation tape after laying the underlay where the edge sealant tape has an adhesive end (for skirting). The edge sealant tape must have a minimum thickness of 3 mm. This thickness is 5 mm increased to for heated floors. Furthermore, you may encounter anhydrite screeds for which the Technical Specification stipulates a thickness of 8 mm edge separation tape when using a heated floors. With 3 thicknesses, several widths starting with 10 cm, with or without an adhesive flap, our range of separation tapes perfectly fulfils the needs of installers in the installation of floating screeds. A full range of separation tapes Use : Separating the floating screed and partitions, skirting boards and pipes. Product Description Width Thickness Heated floor Adhesive raising tape Adhesive raising tape with a flap Heavy-duty tape Polyethylene foam adhered by 2 x 10 mm-wide beads on one side Polyethylene foam made adhesive by a 25 mm-wide bead on one side and a plastic flap (120 mm overlap) Colour Packaging 100 mm 3 mm no white Carton of 6 x 50 ml rolls 145 mm 3 mm no white Carton of 4 x 50 ml rolls 120 mm 3 mm no white Carton of 10 150 mm 5 mm* yes white rolls Polyethylene foam 100 mm 3 mm no white Carton of 14 x 150 ml rolls 5 mm yes white Carton of 14 x 100 ml rolls 145 mm 3 mm no white Carton of 10 x 150 ml rolls 5 mm yes white Carton of 10 x 100 ml rolls 140 mm 8 mm yes blue Carton of 7 x 50 ml rolls * Foam with 5 pre-cuts every cm Velajoint Use : Possible separation tape in-between tiling and the skirting board if the raising tape is not folded back under the skirting board. Product Description Width Thickness Heated Floor Velajoint Making a difference Cross-linked polyethylene foam with adhesive underside Colour 8 mm 2 mm yes white Packaging Carton of 40 x 40 ml rolls B.P 60121-14, rue de Saint-Nazaire - 67025 STRASBOURG CEDEX 1 Tél. 03 88 79 84 00 - Fax. 03 88 79 84 01 - email : contact@soprema.fr www.soprema.fr 08/004F cancels and replaces 07/121F