Vermont Agency of Transportation Annual Report

Similar documents
NATIONAL BRIDGE INSPECTION STANDARDS (NBIS)

BRIDGE INSPECTION REPORTS 101. Protecting Your Bridge Inventory for the Future Jason Kelly, PE

Federal Highway Administration s Role in Bridge Preservation. Anwar S. Ahmad 1

Bridge Management. Developments in Short and Medium Span Bridge Engineering 94. Summary

Bridge Preservation Beyond the Short Term

NEW MEXICO LAND OF ENCHANTMENT

Fracture Critical Bridge Inspection. Presented by MN/DOT Bridge Safety Inspections

VDOT s Experience with Reinforced Concrete and Metal Culverts

According to a Federal Highway

Engineering & Capital Improvements. Shore Acres Civic Association August 21 st, 2017

ODOT Asset Management Plan 0

American Society of Civil Engineers

Evaluation of Bridge Functional Obsolescence Using Congestion Performance Measures Determined from Anonymous Probe Vehicle Data

Responses to questions received following I-526 Wando Bridge closure As of May 31, 2018

What Does the FHWA Rulemaking on Bridge Performance Measures Mean to You?

Asset Management: Federal Perspective on Bridge Maintenance and Preservation

How to Review SI&A Data

AGING AND FAILING INFRASTRUCTURE SYSTEMS: HIGHWAY BRIDGES

Iowa s Deficient Bridges

Perception versus Reality: An Analysis of Timber Bridge Performance in the United States.

State of the Structures and Bridges Fiscal Year 2017 July 1, 2017

STRUCTURE AND BRIDGE DIVISION

Pinellas Bayway Bridge Replacement

The FHWA Long-Term Bridge Performance Program

Movable Bridge Maintenance and Preservation

INSPECTION AND REPAIR OF THE DETERIORATED RT.72 MANAHAWKIN BAY BRIDGE

Joint Legislative Transportation Oversight Committee January 6, 2016 Maintenance Operations Performance Analysis Report (MOPAR) Kristin Barnes

FHWA Update 2017 Michigan Bridge Conference March 22, 2017

Report on. Texas Bridges. as of September Prepared by the Bridge Division Texas Department of Transportation

Inspection Frequency MiSIM Chapter 3

National Transportation Safety Board Washington, D.C

Summary of Critical Findings Reviews for the National Bridge Inspection Program

Clear Creek Road (PM 1.82 & 0.25) Bridge Replacement Projects. Public Meeting, Wednesday, November 20, 2013 Pleasant Valley Middle School

Conceptual Design Report

9 Conclusion. 9.1 Introduction

MAINTENANCE AND REPAIR TABLE OF CONTENTS CHAPTER 32

BRIDGE INSPECTION REPORT

PennDOT District 11 Bridge Asset Management. Louis J. Ruzzi, P.E. District 11-0 (Pittsburgh Area) Bridge Engineer

Designing Bridges for Inspectability

REHABILITATION PACKAGE 4-a

A COMPREHENSIVE BRIDGE PRESERVATION PROGRAM TO EXTEND SERVICE LIFE. Bruce Johnson 1

BRIDGE INSPECTION Part of a diversified family of solutions. jmt.com

Bridge Inspection. Part of a diversified family of solutions. www. jmt.com. An Employee Owned Company

Bridge Model Validation at Indiana DOT Gary Ruck, P. Eng., PMP, Deighton

Bridge Inspection Manual. Revised July 2002 by Texas Department of Transportation (512) all rights reserved

CLA /10.54, PID Project Description:

GEOMETRIC DESIGN CRITERIA for Non-freeway Resurfacing, Restoration, and Rehabilitation Projects

9D - BRIDGE INSPECTION

VDOT s Strategic Approach to Bridge Management and Maintenance

Keep Roads and Bridges in Good Condition. Dennis Heckman, State Bridge Engineer. Tracker. Measures of Departmental Performance

Keep Roads and Bridges in Good Condition. Dennis Heckman, State Bridge Engineer. Tracker. Measures of Departmental Performance

BRIDGIT: User-Friendly Approach to Bridge Management

National Bridge Inspection Program Risk-based, Data-driven FHWA Oversight

State of New Jersey NEW JERSEY DEPARTMENT OF TRANSPORTATION 1035 PARKWAY AVENUE P.O. Box 600 TRENTON, NEW JERSEY

ASCE STRUCTURAL ENGINEERING CONFERENCE. Ames Iowa

Moving Ahead for Progress in the 21 st Century Act MAP-21

Norfolk Southern s Online Rebuild of the Coosa River Bridge

NOVEMBER 2016 TRANSPORTATION ASSET MANAGEMENT PLAN

Implementing Asset Management: WSDOT s Experience

2016 STRUCTURE INSPECTION APPRAISAL REPORT. Prepared For: THE CORPORATION OF THE TOWNSHIP OF AMARANTH COUNTY OF DUFFERIN

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PREFABRICATED STEEL PEDESTRIAN BRIDGE, TYPE 1

St. Anthony Falls I-35W Bridge Replacement. ASHE National Conference June 13, Dustin Thomas, P.E. I-35W Bridge Construction Engineer

FHWA Bridge Program Initiatives - Bridge Design and Analysis

S T R U C T U R. Lessons Learned. magazine. Bridge Industry. Copyright. One Year After the Minneapolis Bridge Collapse. By Brian J. Leshko, P.E.

AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS, CENTER FOR ENVIRONMENTAL EXCELLENCE, HISTORIC BRIDGES COMMUNITY OF PRACTICE

SIAMA. SIAMA Asset Management Technologies Level-2 Bridge Condition Inspection

Minnesota Department of Transportation (Mn/DOT) Historic Bridge Management Plan

MICHIGAN DEPARTMENT OF TRANSPORTATION

Replacing the Aging US 52 Mississippi River Bridge

HOW WILL THE NATION SATISFY GROWING DEMAND WITH LIMITED FUNDS? Europe 2,980. United States 1,130

Northeast Bridge Preservation Partnership Meeting

Categorical Exclusion Programmatic Agreement Between the Federal Highway Administration And the Indiana Department of Transportation

Appendix A: Project Planning and Development A-1 White Paper on Transit and the Tappan Zee Hudson River Crossing Project

Transportation Asset Management Webinar Series

Red Wing Bridge Alternates

THE COMMONWEALTH OF MASSACHUSETTS NON-NHS BRIDGE R&R POLICY

NEW JERSEY DEPARTMENT OF TRANSPORTATION MEMORANDUM

Washington State DOT: Pavement and Bridge Performance NPRM Comments for federal docket,

Overview of Maintenance and Construction Programs. Mike Holder, PE, Chief Engineer Jennifer Brandenburg, PE, State Asset Management Engineer

Maintenance, Construction & Secondary Roads. Terry Gibson, PE Chief Engineer February 20, 2013

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PREFABRICATED STEEL PEDESTRIAN BRIDGE, TYPE 2

VTCA CONFERENCE Structure and Bridge Update. Kendal R. Walus, PE State Structure and Bridge Engineer. April 13, 2018

ODOT Bridge and Pavement Funding Allocation Business Process. Bruce Johnson 11 th IBSMC, Mesa Arizona 4/24/17

MONTANA TRANSPORTATION BY THE NUMBERS:

MnDOT Bridge Load Rating and Evaluation Manual TABLE OF CONTENTS

2008 Michigan Bridge Conference March 19, 2008 Mount Pleasant, MI

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PREFABRICATED STEEL PEDESTRIAN BRIDGE, TYPE 2

TRANSPORTATION PERFORMANCE MANAGEMENT

TITLE: Bridge Inspection and Evaluation Procedure

Dynamics and Field Testing of Bridges

Chester Bridge Environmental Assessment (EA) CAG Meeting #2. October 12, 2017

Tri-State Performance Measures Annual Report

Addendum #3 to the Regional Transportation Plan

MICHIGAN DEPARTMENT OF TRANSPORTATION

SAN ANTONIO STREET BRIDGE AT COMAL RIVER. Open House

MILTON-MADISON BRIDGE REPLACEMENT

2-2 ALTERNATIVES CONSIDERED AND ELIMINATED

National overview of the bridge condition and management: Japan

Local Bridge Removal Policies and Programs

SEISMIC DESIGN AND RETROFIT OF BRIDGES ON MISSOURI S EARTHQUAKE PRIORITY ROUTES

Transcription:

Vermont Agency of Transportation Program Development Structures Section 2011 Annual Report Interstate Bridge Program State Highway Bridge Program Town Highway Bridge Program *Moretown-Middlesex US 2, bridge # 50 over Winooski River January 12, 2011

Table of Contents Executive Summary 2 3 Vermont s Bridge Population 4 Aging Bridge and Culvert Inventory 5 Bridge Inspections and Condition Ratings 6 7 Restrictions 8 Structurally Deficient and Functionally Obsolete 9 11 New Performance Goals and Measures 12 13 Preventive Maintenance, Project Selection, and Prioritization 14 15 Challenges and Opportunities 16 17 *Newfane (Williamsville Covered Bridge) TH 2, bridge # 17 over Rock River 1 of 17

Executive Summary Bridges are integral elements of our highway systems. Despite their importance, the past several decades have produced a pattern of neglect. Demands on limited resources too often result in deferred maintenance for bridges. Without adequate attention, many bridges will require replacement, restriction, or closure long before their desired lifespan is complete. This will only further stress Vermont s limited transportation resources, restrict Vermonters mobility, and negatively affect the State s overall economy. Vermont has 2,694 long structures greater than 20 feet on Interstate, State, and Town routes and another 1,286 short structures between 6 and 20 feet on the state system that VTrans inspects. Inspections are conducted every 24 months on long structures and every 60 months on short structures unless conditions warrant more frequent inspections. Deck, superstructure, substructure, and channel conditions are all evaluated and each component is ranked on a scale of zero to nine, with nine indicating an excellent condition and zeros a failed condition. Conditions are reported to the FHWA and a condition rating of four (poor) or lower for any component determines that the bridge is structurally deficient. Of those 2,694 long structures, 12 percent are considered structurally deficient by federal standards. Using FHWA s latest bridge data, Vermont ranks 42 nd among the 50 states for percentage of structurally deficient bridges. This is due, in large part, to the age of our bridge network. Many of our bridges replaced bridges flooded in 1927 and are now in need of replacement or major rehabilitation. Our interstate bridges are approaching 50 years of age and are now in need of rehabilitation. To address these needs Vermont utilizes a Bridge Management System and Prioritization System to identify appropriate treatments for the bridge network and the appropriate timing. These treatments can range from complete replacements and major rehabilitations to preservation activities like preventive maintenance. Bridge conditions are improving. Funding increases have occurred nearly every year from $48.7 million in FY 05 to $112.7 million in FY11. This is a result of numerous congressional earmarks, ARRA funding, Bridge Maintenance funding, and Administration and Legislative support in recent years. The Road to Affordability Policy keeps our focus on maintaining and improving our existing infrastructure. Vermont has recently ramped up its Bridge Maintenance and Preservation activities that will pay dividends well into the future also. From its modest start of $4.7 million in FY06, Bridge Maintenance has climbed to $32.2 million in FY11. These treatments do little to improve structural deficiencies, but will extend the lives of our better bridges. 2009 inspections resulted in a 111 bridge reduction in structural deficiencies; that s a 4.1% improvement. Of those, only 23 bridges actually had documented maintenance or replacement projects. That year inspectors were rotated so there were new sets of eyes on the bridge conditions. 2 of 17

While most of the differences can be attributed to the allowable tolerance of inspector s ratings, we have new procedures in place to get more eyes on a bridge when ratings move between a five and a four. That marked improvement in bridge condition ratings allowed us to exceed our performance goals in all three bridge programs: Interstate, State, and Town Highway Bridge. These goals were set many years ago when conditions were worse than they are today. Given our current conditions and national ranking, we are setting new performance goals for the state. Our strategy varies with the highest standard for the interstate where traffic and expectations are highest. State bridges provide greater movement of people and goods than town bridges so state bridge standards will fall between the interstate and town highway bridge standards. Vermont s goal for percentage of bridges that are structurally deficiency is 6% for the interstate, 10% for state bridges, and 12% for town bridges. We are poised to introduce new performance measures that better reflect the state of bridge conditions and help us better manage bridge assets. We have been working with our counterparts in Northern New England over the last year and have just agreed on how to go forward. Those new measures are the percentage of structurally deficient bridge deck area and system bridge condition index. We continue to work with our counterparts to set performance goals for these measures and will track and report on them in the future. *Lincoln TH 9, bridge # 48 over New Haven River 3 of 17

Vermont s Bridge Population In conformance with the National Bridge Inventory (NBI), Vermont maintains an historical record of all bridges subject to the National Bridge Inspection Standards (NBIS). These standards establish requirements for inspection procedures, frequency of inspections, qualifications of personnel, inspection reports, and both the preparation and maintenance of a state bridge inventory. The NBIS apply to all structures defined as bridges that are longer than 20 feet in length and located on public roads. These assets are commonly referred to as long structures. Short structures are those not classified as a long structure and have a span length equal to or greater than six feet. Structure Type Long Structures (span length > 20 feet) Vermont s Highway Structure Population (as reported to FHWA in April 2010) Interstate 313 (48 buried structures)** State Highway 765 (56 buried structures) Town Highway 1,610 (76 buried structures) Other 6 (2 buried structures) Total 2,694 (182 buried structures) Short Structures (span length 6 feet and 20 feet) 218 (218 buried structures) 1,068 (888 buried structures) *** (see note) *** (see note) 1,286 (1,106 buried structures) Totals 531 1,833 1,610 6 3,980 **Buried structures include metal culverts, concrete box culverts, frames, masonry arches, and concrete arches. ***Note: VTrans does not maintain an inventory of town highway or other short structures. Structure Type Railroad Bridges (state-owned railroads) Retaining Walls (height greater than 3 feet) Recreational Path Structures (span length greater than 6 feet) Vermont s Off-Highway Structure Population (as of December 2010) State Highway 216 261 Town Highway **** (see note) **** (see note) Total 216 261 0 110 110 Overhead Sign Support Structures 134 **** (see note) 134 Totals 611 110 721 ****Note: VTrans does not maintain an inventory of municipally-owned retaining walls or overhead sign support structures or privately-owned railroad bridges. Note: This number is expected to change as inspection criteria is refined (i.e., minimum sign size, attachment, etc.). 4 of 17

Aging Bridge and Culvert Inventory With 1927 flood-era bridges now over 80 years old and nearing the end of their useful design life, as well as the 1958-to-1978 Interstate-era bridges around the 40-year mark and in need of repairs, a wave of structures in need of major investment is quickly approaching. Structure Count 800 600 400 200 0 26 135 0-9 31 193 10-19 50 239 20-29 132 369 30-39 Age of Structures 267 413 40-49 264 227 50-59 143 134 60-69 Age in Years *based on year of original build 158 396 70-79 Interstate and State Highway Short Structures Interstate, State Highway, and Town Highway Long Structures Vermont s bridges are similar to the other northern New England states but are considerably older than the national average. Covered bridges, steel truss bridges, and other historic structures contribute to our village centers and scenic character. These older bridges require regular maintenance and are a challenge to keep serviceable. 121 314 80-89 94 274 90 plus 20.0 25.0 18.0 % by Age Group 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 20.0 15.0 10.0 5.0 % SD in Age Group 0.0 0-9 10-19 20-29 30-39 40-49 50-59 60-69 70-79 80-89 90 plus 0.0 Age *Based on FHWA Data (December 2009) % by Age (Vermont) % by Age (Tri-State) % by Age (National) % SD (Vermont) % SD (Tri-State) % SD (National) 5 of 17

Bridge Inspection and Condition Ratings The nation s current bridge inspection practice was established largely as a response to disasters involving bridge failures. With each failure, new facts were learned and new standards implemented. Here is a short list of some events that have dramatically influenced national inspection and maintenance practice. On December 15, 1967, the 2,235-foot Silver Bridge at Point Pleasant, West Virginia collapsed into the Ohio River killing 46 drivers and passengers. This tragic accident aroused national concern about bridge safety inspection and maintenance, and motivated Congress to enact improvements to the Federal Highway Act of 1968. Three years later in 1971, National Bridge Inspection Standards (NBIS) were created, setting national policy for inspection frequency, inspector training and qualifications, reporting formats, and procedures for inspection and rating. During the 1970s, similar attention was also directed to culverts after several collapses claimed more lives. In 1983, the Mianus River Bridge in Connecticut collapsed after one of its pinand-hanger assemblies failed, leading to an emerging national emphasis on fatigue and fracture-critical elements. In April 1987 with the fall of the Schoharie Creek Bridge on the New York Thruway, new attention also was focused on underwater inspection of bridge foundations. And most recently, in August of 2007 the I-35W highway bridge over the Mississippi River in Minneapolis collapsed. Undersized steel plates and the stress of 287 tons of stockpiled construction material were singled out in the National Transportation Board (NTSB) Accident Report as reasons for the failure. Federal safety investigators said the collapse was unavoidable once gusset plates in the bridge's center span failed, dragging other sections and rush-hour commuters into the Mississippi River. The collapse killed 13 people and injured 145 others. This has lead to an emphasis on gusset plate inspection and design. *Addison, VT Crown Point, NY construction of pier # 7 over Lake Champlain 6 of 17

Guided by federal requirements, all bridges in excess of a 20-foot span and located on public roads receive regular, biennial inspections by qualified personnel to ensure safety of the traveling public. Short structures, those between 6 feet and 20 feet in span length, located on either the Interstate or state highway systems are inspected once every 60 months. Bridge safety is taken very seriously. If deemed necessary because of deteriorating conditions, bridges are inspected more frequently. Through periodic safety inspections, data is collected on the condition of each structure s primary components. Condition ratings are collected for the following bridge components: Deck: The portion of a bridge that provides a surface for vehicular or pedestrian traffic. Superstructure: The portion of a bridge above the substructure that supports the deck, including beams, girders, trusses, and bearing devices which support traffic and transfer the loads to the substructure. Substructure: The portion of a bridge below the bearing device, built to support the superstructure and transmit loads to the foundation. The culvert condition rating describes all structural elements of culvert designs which do not have a distinct deck, superstructure or substructure, and are buried under fill. The channel and the channel protective system are also rated, describing the physical conditions of slopes, as well as the channel or water flow through the bridge. Bridge inspectors utilize a point system from zero to nine, where nine indicates an excellent condition and zero indicates a failed condition. Inspectors visually assess the ratings based on engineering expertise, training, and experience. These ratings form the basis for assessing the structural condition of the bridge. Recommendations for maintenance needs, load restrictions or closure originate with, and are based on, inspection findings. Inspection provides a visual record of structural health including deterioration and the consequent determination of a structure s ability to continue to perform in a safe manner. The challenges faced in the northeast having an older and aging infrastructure, seasonal limitations on performing inspections, extensive use of deicing salts, and accelerated corrosion rates are among the more demanding, and the importance of routine inspections cannot and should not be underestimated. *Brattleboro I-91, bridge # 6 *Berlin I-89, bridge # 37 *Rockingham I-91, bridge # 24 7 of 17

Restrictions As VTrans searches for the most appropriate performance measures to help target which structures are in most need of repair or rehabilitation, it is important for the Agency to understand how much ground is either being lost or gained in terms of keeping our assets open and unrestricted for public travel. Restrictions a limitation of or inability to use a structure come in four basic categories: Closed: bridge closed to all traffic. Temporary: open but with a temporary structure in place to carry legal loads while original structure is closed and awaiting replacement or rehabilitation. Posted: reduced maximum allowed weight. Posted structures may include other restrictions such as temporary bridges which are load posted. Restricted: posted for other load capacity restrictions such as speed, number of vehicles, vertical clearance, etc. Due to recent public attention on the condition of our bridges, many believe Vermont has more restricted bridges than it did 10 years ago, when in fact the state has slightly fewer. Despite this reduction in the overall number of restricted bridges, as our infrastructure ages this trend becomes more difficult to maintain in the future. 200 Totals* 150 142* 129* 119* 100 50 12* 12* 10* 0 2000 State 2005 State 2010 State 2000 Local 2005 Local 2010 Local Restricted 2 1 0 28 34 33 Posted 5 6 4 90 71 67 Temporary 3 4 5 11 11 7 Closed 2 1 1 13 13 12 8 of 17

Structurally Deficient and Functionally Obsolete The Agency is evaluating a number of performance measures by which to judge how well we are maintaining our structure assets. Measures such as bridge health index, averaged condition, worst condition, numbers of structurally deficient and functionally obsolete bridges, and the number of restricted, posted, closed, or temporary bridges are all being considered. For many years, the Federal Highway Administration (FHWA) has used structural deficiency and functional obsolescence as a measure. VTrans, however, uses percent bridges structural deficiency by system (interstate, state highway, and town highway). Where do the terms structurally deficient and functionally obsolete come from and how are they defined? Both are terms FHWA uses to classify bridges according to serviceability, safety, and essentiality for public use to meet the requirements of Title 23 of the United States Code (23 U.S.C. 144). The technical definitions are as follows (source: 23 C.F.R. 650D). Structurally Deficient (SD): A bridge becomes structurally deficient when at least one of six items from the National Bridge Inventory (NBI) reaches a set threshold. The criteria are a Deck Condition Rating, Superstructure Condition Rating, Substructure Condition Rating, or Culvert Condition Rating of 4 (Poor Condition) or less, or a Structural Evaluation Appraisal Rating or Waterway Adequacy Appraisal Rating of 2 (basically intolerable requiring a high priority of replacement) or less. Any bridge that is classified structurally deficient is excluded from the functionally obsolete category. Functionally Obsolete (FO): A bridge becomes functionally obsolete when at least one of five items from the National Bridge Inventory reaches a set threshold. The criteria are a Deck Geometry Appraisal Rating, Underclearances Appraisal Rating, Approach Roadway Alignment Appraisal Rating, Structural Evaluation Appraisal Rating or Waterway Adequacy Appraisal Rating of 3 (basically intolerable requiring a high priority of corrective action) or less. Any bridge that is classified structurally deficient is excluded from the functionally obsolete category. Highway bridges classified as functionally obsolete are not structurally deficient, but according to federal standards their design is outdated. They may have lower load carrying capacity, narrower shoulders or less clearance underneath than bridges built to the current federal standard. Vermont, due to the historic nature of its bridges as well as environmental concerns associated with bridge widening, has established state standards that differ from federal standards. As a result, it is possible for a new bridge built in Vermont to be classified as functionally obsolete. Also, Vermont does not always modernize its functionally obsolete bridges. An example is the state s covered bridges, which are functionally obsolete, but no one wants them altered. 9 of 17

While functional obsolescence is not one of our performance measures, we report it here as a federal measure. It is important to note that when structural repairs are made to structurally deficient bridges the functional obsolescence count may rise. The fact that a bridge is structurally deficient (SD) or functionally obsolete (FO) does not mean the bridge is inherently unsafe. The VTrans inspection unit takes bridge safety very seriously. If unsafe conditions are identified during an inspection, the structure will be restricted or closed. Vermont s Functional Obsolescence (FO) and Structural Deficiency (SD) Population (as of or reported to FHWA in April 2010) FO % FO SD % SD Interstate Long Structures 93 29.7% 21 6.7% State Highway Long Structures 99 12.9% 86 11.2% Town Highway Long Structures 336 20.9% 215 13.4% On-System Short Structures N/A N/A 131 10.2% System Total 528 453 Note: FO and SD are federal labels and are not applied to short structures. This number represents short structures having a condition rating of poor or less. Interstate Trends 50% Deficiency Status (%) 40% 30% 20% 10% 0% 89 92 87 90 89 88 93 93 90 90 35 35 40 40 35 32 15 15 22 21 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Functionally Obsolete Structurally Deficient Submittal Year 10 of 17

State Highway Trends 50% Deficiency Status (%) 40% 30% 20% 10% 94 97 100 88 87 87 85 87 88 149 149 148 152 153 157 157 158 156 99 86 Functionally Obsolete Structurally Deficient 0% 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Submittal Year Town Highway Trends 50% Deficiency Status (%) 40% 30% 20% 10% 305 297 273 283 291 318 287 289 285 293 305 295 328* 311* 305 304 336 255 336 215 Functionally Obsolete Structurally Deficient 0% 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Submittal Year *Corrected to Reflect Oversight in NBI Inventory Rating Reporting Format 11 of 17

New Performance Goals and Measures In the past, VTrans relied on the Federal Highway Administration s measures of structural deficiency and functional obsolescence to evaluate bridge condition. Vermont, however, is evaluating new performance measures that VTrans believes better model the average condition of Vermont s bridge network. The federal measures do not do a good job evaluating a bridge s true condition, so VTrans is exploring the use of measures that better quantify critical conditions. VTrans is not doing away with the federal measures, and the Agency will continue to supply FHWA data for these determinations. The federal measures Structural Deficiency and Functional Obsolescence imply but do not really tell us anything about the bridge s overall condition, nor do they tell us how bad a particular bridge component is. The federal measures only indicate that one or more bridge components have deteriorated to a point where they are within a range that requires assessment. They may or may not need treatment. For example, our interest in fitting bridges into the historic Vermont landscape all covered bridges and many historic truss bridges are considered functionally obsolete lead to the development of Vermont specific standards that allow us to design bridges narrower than the federal standards. Many of Vermont s new designs and rehabilitations are considered functionally obsolete though they function very well. To better evaluate our structures VTrans, together with Maine and New Hampshire, is working to develop and implement a more holistic approach to measuring the condition and performance of our structures. Although these efforts are still in development, Vermont and the other states see promise in utilizing a condition index as an effective management tool that can be compared across state lines. Bridge condition index (BCI), percent structurally deficient by deck area, and the national deficiency comparison (number of SD/FO bridges) are the measures being used and evaluated at the tri-state level (Maine, New Hampshire, and Vermont). The goal is to develop a network measure which reflects the relative health of our bridge population. % Structurally Deficient Deck Area *as of December 2009 FHWA data 20 17.84 15 10 7.62 8.13 12.71 16.01 14.81 12.71 11.38 15.55 Maine New Hampshire Vermont 5 0 NHS Non-NHS All Bridges 12 of 17

Bridge Condition Index (BCI) Comparison *based on 2009 NBI data - all bridges 100% 90% 80% 70% 60% 50% 40% 30% "A" - Excellent "B" - Good "C" - Fair "D" - Poor "E" - Unacceptable 20% 10% 0% Maine New Hampshire Vermont As the Agency moves to new performance measures, structural deficiency performance goals will continue. Previously published goals for interstate long structures (7%), state and town highway long structures (16%), and interstate/state short structures (12%) have been met and there is room for improvement. VTrans is proposing to raise the bar and strive towards the following goals: 6% on the interstate system (18 bridges) 10% on the state highway system (76 bridges) 12% of the town highway system (193 bridges) 10% of interstate/state highway system culverts (128 culverts) The following chart represents the change in percent of structural deficiency by system over a 10-year period with the new performance goals. 30.0 1999 - April 2000 Submittal 2004 - April 2005 Submittal 2009 - April 2010 Submittal Structural Deficiency over Time by System *April Submittal Years 2000, 2005, and 2010 24.7 Percent of Bridges 20.0 10.0 12.8 6.7 *6% Goal 20.9 20.0 11.2 *10% Goal 16.3 13.4 *12% Goal 17.6 10.2 *10% Goal 4.5 0.0 Interstate Bridge State Highway Bridge Town Highway Bridge State Shorts *Proposed Performance Goals 13 of 17

Preventive Maintenance, Project Selection, and Prioritization In compliance with H.523 legislation, a priority ranking system for existing long structure projects, rehabilitation and replacement, was developed based on the following factors: Bridge Condition (30 points maximum) Remaining Life (10 points maximum) Functionality (5 points maximum) Load Capacity and Use (15 points maximum) Waterway Adequacy and Scour Susceptibility (10 points maximum) Project Development and Momentum (5 points maximum) Regional Input and Priority (15 points maximum) Asset Benefit Cost Factor (10 points maximum) Points are then summarized for each program, with the highest score receiving the top ranking. Rankings will change from year to year as projects are completed, as bridges change in condition, or as regional planning commissions priorities change. These priorities are used in developing the capital program, help in deciding which bridges to advance next, and have enabled us to clear a backlog of projects in a defined, documented, and efficient manner. Selection for proposed rehabilitation and reconstruction projects will continue to utilize the priority system. To become a project and have design initiated, the bridge will need to be among the highest ranked. The establishment four years ago of the bridge maintenance program gave us a start, enabling us to perform much-needed preventive maintenance on a limited number of bridges, but it was just the beginning. Preventive maintenance is not a high-profile activity; but if done on a routine schedule, its benefits will be obvious as it will extend service life and delay the rate at which our bridges become structurally deficient. The Agency has substantially grown the program from its origins and has now integrated it into the regular program. *Bristol TH 5, bridge # 31 over New Haven River 14 of 17

The bridge priority system, which is used to rank major bridge replacement and rehabilitation projects, will continue to be used for project selection and determining funding needs. However, this system is not inclusive as it does not rank short structures or maintenance needs, both preventive and routine. Bridge replacement and rehabilitation projects progress through the VTrans Project Development Process. This process for a typical project is a multi-year effort from inception to construction. The Structures Section is working to both reduce and contain project scope and costs. Reduced scopes will accelerate the projects by reducing impacts and streamlining the process and therefore reduce engineering costs. Scope reduction can be achieved by various methods: reducing approach work, eliminating enhancements and, where possible, closing the roadway during construction. Although sometimes inconvenient for a community, the elimination of a temporary bridge reduces timelines, cost, need for significant right-of-way acquisition, and resource impacts. Closing the roadway can also speed construction. Where appropriate, rapid bridge techniques and materials are utilized. The technique minimizes traffic disruptions and congestions, improves work-zone safety, and lessens environmental impacts. Additionally, prefabrication can improve constructability, increase quality, and lower life-cycle costs. Focusing efforts toward preventive maintenance activities will slow, but not reduce the number of bridges becoming structurally deficient. Preventive maintenance does not correct existing structural deficiencies, but instead retards deterioration so that a bridge s lifespan can be extended, thus preventing the structure from becoming structurally deficient. To this end, preventive maintenance is essential to slowing the rate at which structural deficiencies evolve over time. The value of preventive maintenance will be appropriately demonstrated in the future through new performance measures that evaluate a bridge s overall core unit condition or network health. *Stockbridge VT 107, bridge # 9 over Stoney Brook *Maidstone VT 933, bridge # 1 over Connecticut River 15 of 17

Challenges and Opportunities Both nationwide and here in Vermont, bridges are aging as traffic demands increase. Two major events the 1927 flood and the construction of the interstate system saw large numbers of structures built within short time frames. Vermont s challenge is how to properly plan for and meet the needs of these aging structures. Meeting this challenge is multifaceted and includes everything from having a vigilant inspection program to using asset-management principles to guide decisions and a commitment to maintaining a long-term preventive maintenance program. To assure public safety, our inspection crews will continue their vigilance and incorporate into their work improved bridge inspection techniques that utilize new and innovative equipment. Using asset-management principles that utilize both bridge management systems and transportation system-preservation techniques is vital as states work to maintain safe bridge conditions. Bridge maintenance is not just about fixing bridges when they break down. Proper care uses preventive maintenance to breathe new life into not-so-new bridges before they have the chance to deteriorate. Frequent inspections, not just by trained inspectors but also by those tasked with routine maintenance, along with a robust preventive maintenance program is vital to extending performance, keeping costs down, and maintaining safety. Although the benefits of preventive maintenance are widely recognized, bridge owners face funding challenges. Without tangible incentives, maintenance deferment will continue. In response, educational outreach efforts have been conducted, coupled with funds targeted for maintenance activities. The purpose of this effort is to address maintenance needs in a timely fashion, and thereby cost-effectively extend the useful life of structures. Advancing preventive maintenance, improving prediction models, applying emerging technologies, developing decision-making tools, and refining appropriate performance measures and goals are just some of the opportunities that VTrans is committed to moving forward. We will continue to work with municipalities so they not only understand the need, but have the necessary tools to maintain and preserve their assets. Reducing the number of structurally deficient bridges and improving overall network conditions with both targeted maintenance and cyclical preventive maintenance treatment is the primary charge of the Structures Section. To prioritize efforts, control costs, and deliver projects efficiently, the Road to Affordability eliminated projects with no foreseeable funding plan. To streamline the process and therefore save both time and money, the Road to Affordability also emphasizes scope containment, a reduction in the use of temporary bridges, and the proliferation of accelerated bridge techniques and materials where appropriate. 16 of 17

To prepare for potential funding growth in conjunction with possible economic stimulus and bonding packages, efforts in plan development, permit clearance and rightof-way acquisitions will be enhanced to promote a streamlined project development and contracting process. Alternative contracting methods, including design-build contracts and the use of simplified designs, standards, and contracting are being evaluated. Initial experience seems promising so each method is being considered as options for future projects. The refinement of bridge priorities, coupled with new and improved bridge performance measures and goals, as well as management predictive models, will continue to evolve and develop into trusted and valuable tools. Legislative and administration support for bridges remains strong, and diligence will have its rewards. Excellent bid prices, efficient designs, and strong funding levels that support bridge maintenance and rehabilitation efforts are cause for excitement and a readiness to succeed. *Cornwall VT 125, bridge # 9 over Lemon Fair River Please refer to the online version of this report for additional copies. http://www.aot.state.vt.us/progdev/documents/structures/2011structuresannualreport.pdf The Treasure s report on bridges and culverts is available online as an additional resource. http://www.vermonttreasurer.gov/sites/treasurer/files/pdf/misc/transportationreportrevisednov1508.pdf 17 of 17