Conditions of the Contract and Division 1 General Requirements are a part of this section.

Similar documents
REINFORCED CONCRETE MASONRY SECTION

SECTION UNIT MASONRY

SECTION ARCHITECTURAL CONCRETE UNIT MASONRY

Paragraph Description Page No General Materials Concrete Masonry Work Altitude Valve Vault Cover 25-4

SECTION MORTAR

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE

1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:

SECTION UNIT MASONRY ASSEMBLIES

SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING

SECTION BRICK MASONRY ASSEMBLIES

SECTION BRICK FLOORING

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) MASONRY [BLOCKS] [BRICKS] [STONE]

SECTION UNIT PAVERS

1 Exam Prep Concrete Masonry Handbook Questions and Answers

1. Repairing brick masonry, including replacing damaged units as indicated on drawings. 2. Repointing mortar joints.

SECTION MASONRY GROUTING

SECTION Vitrified Clay Wall Coping 2014

DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340

SECTION CAST-IN-PLACE CONCRETE

1. Section , Concrete Reinforcement and Embedded Assemblies. B. ACI 530/ASCE 5 - Building Code Requirements for Masonry Structures

SECTION US Patent 8,857,130 B1 CAST-IN-PLACE CONCRETE WITH ARDEX CONCRETE MANAGEMENT SYSTEMS (ACMS ) EARLY MC APPLICATION

SECTION UNIT MASONRY

MASONRY MORTARING

SECTION Fiber Reinforced Stucco 1

Division 04 - Masonry Section New Westminster Multi-Use Civic Facility & Office Building Project No Page 1

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

CONCRETE TILE PAVERS

1. Concrete pavers, with ungrouted joints, over sand base. a. Large precast sections in random mix with smaller concrete pavers

SELECT APPROPRIATE SECTIONS FOR BELOW; DELETE OTHERS

PAVING SLABS ON AGGREGATE BED FOR ROOF PLAZA DECKS

PROGRAM COMMENT FOR DEPARTMENT OF DEFENSE REHABILITATION TREATMENT MEASURES

INSULATED CONCRETE MASONRY UNITS Section 04220

SECTION SPLIT FACE CONCRETE MASONRY UNITS

SPECIFICATION GUIDELINE

MANUFACTURER S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON HEMPCRETE

SECTION TILT-UP PRECAST CONCRETE. A. Work includes, but is not limited to, the following:

MANUFACTURER S SPECIFICATIONS Section LIMESTONE PLASTER

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

SPECIAL SPECIFICATION 4491 Type CAC Concrete

SECTION RIGID PAVEMENT. 1. Portland Cement Concrete (PCC) pavement. 2. Section Aggregate Base Course.

DURRELL DESIGN GROUP, PLLC ROOF REPLACEMENT BARR ELEMENTARY SCHOOL JACKSON PUBLIC SCHOOL DISTRICT JACKSON, MISSISSIPPI.

REFLECTIVE FACE CONCRETE MASONRY UNITS

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

Kinds of Mortars. Mortar. Specifying Mortar. Proportion Specifications. M a S o N w O r K. Specification for Mortar Cement

SPECIFICATION GUIDELINE

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

Construction Standards PAGE

1-2-3MORTAR Modified Portland cement based mortar, to be used to adhere any prefabricated construction elements

SECTION CONCRETE UNIT MASONRY. A. Section Includes: Concrete unit masonry construction as shown on Drawings and as specified.

Master Specifications for Microcotta November 2017

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SECTION GLASS UNIT MASONRY ASSEMBLIES

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SECTION RIGID PAVEMENT

Proposed Modification to the Florida Building Code

SECTION CAST IN PLACE CONCRETE FOR FLOOR SLABS ON GRADE THAT WILL RECEIVE SEMI-PERMEABLE OR IMPERMEABLE FLOOR FINISHES

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

.2 Provide for compartments in long cavity wall and at corners to achieve appropriate pressure equalization and drainage in cavity wall design.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

The Admixture Systems business of BASF Corporation previously conducted business as Degussa Admixtures, Inc. and Master Builders, Inc.

Concrete Block Machines Typical Fixed Block Machine

SECTION GROUND FACE CONCRETE MASONRY UNITS

VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR CONCRETE FORM LINERS AND COLOR STAIN COATING

Custom Polishing Systems

SECTION Specification for Building Limes Specification For Building Sands from Natural Sources Methods of Tests for Paints.

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

ReCote Finish System over Concrete

SECTION LIMESTONE PAVING

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

SPECIAL SPECIFICATION 4703 Repair Of Impact Damaged Prestressed Concrete Bridge Beams

SECTION Arisfor WallGuard

SECTION PORTLAND CEMENT PLASTER (STUCCO) WITH ACRYLIC FINISH

1. Payment for concrete sidewalks is on square foot basis. a. Limits for measurement for trench excavation as follows:

AIA Disclaimer Notice

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI)

SECTION SHOTCRETE Cast-In-Place Concrete Precast Prestressed Concrete Joists and Beams.

for Mortar-Set Concrete Tiling Installations

BYU CITY FIRE STATION

SECTION CONCRETE CURBS, GUTTERS AND SIDEWALKS

Section Shotcrete

Section CONCRETE SIDEWALKS. 1. Payment for concrete sidewalks is on square foot basis.

Narrow Modular Pavers (NMP) for Mortar-Set Concrete Tiling Installations

04221 CONCRETE UNIT MASONRY

SECTION PRECAST CONCRETE COVER SYSTEM

SECTION MECHANICALLY STABILIZED EARTH RETAINING WALLS

SECTION PORTLAND CEMENT CONCRETE PAVEMENT. All subsurface utilities must be inspected, tested, and accepted prior to any paving.

ARISTOCRAT - THE AIR LEAKAGE CONTROL BLOCK

BRICKWORK 3.5 BRICKWORK 1 GENERAL

DIVISION 3 - CONCRETE Section Concrete Toppings Section Concrete Resurfacing Section Concrete Rehabilitation

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

DIVISION 3 - CONCRETE Section Concrete Rehabilitation

Effective Mortar Specifications. Jamie Farny PCA Market Manager Buildings June 24, 2015

Thin Architectural Splitface Block Veneer Specification Guide

G. Shop drawing of wall with all dimensions, details, and finishes. Drawings must include post foundations.

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

Desco Granite Flooring Specifications

GYPSUM BOARD AND PLASTER

LITHOCRETE ARCHITECTURAL CONCRETE PAVING

Transcription:

NOTES TO SPECIFIER General notes about the specifications and the reasons for them are listed here in general statements. Use this as a guide when choosing the correct selection of statements that apply to your job from the actual specifications. A.S.T.M. C-90-96, UBC Standard 21-4 These specifications are based on A.S.T.M. C-90-96-. When particular features are designed such as weight classification, higher compressive strengths, surface textures, finish, color, fire resistance, insulation, acoustical properties, or other special features; such properties should be specified separately and clearly by the purchaser or architect. However, Orco Block should be consulted as to the availability of units having the desired features. TYPE OF BLOCK Selecting the proper type of block for your job is very important. Texture means you are using slump block, split face, or precision block. Specify and indicate the proper type or types to be used and their locations. SAMPLE PANEL A sample panel is important because it serves as a visual aid for workmanship for the masonry contractor and architect. This helps to eliminate later discussion about workmanship standards. In lieu of the sample panel, begin work in the most obvious section designated by the architect and this will serve as the sample panel. CERTIFICATES Specify being a participant in the Q block test program because this is the way the owner and architect are sure they are getting a quality manufacturer who is tested every quarter rather than every year as the A.S.T.M. requires. Also in the Q block test program, the blocks are picked up from a job site rather than from the plant once a year as the A.S.T.M. requires. The companies who participate think enough of their product to pay or these additional tests themselves and are competitive with the manufacturers who do not participate. COLOR Colored block usually has to be manufactured, especially on large products. It is also one of the first items to be installed. To avoid a possible delay in construction, select the block color before bidding the job. This will take the guesswork out of the bidding process because the cost of color in block does vary. This also alerts the general contractor to notify the masonry contractor, who in turn should be expedient in placing the order with his supplier. ORCO BLOCK COMPANY S SUGGESTED BLOCK MASONRY SPECIFICATION SECTION 04220 - CONCRETE UNIT MASONRY Conditions of the Contract and Division 1 General Requirements are a part of this section. PART GENERAL 1.01 SUMMARY A. Provide materials, labor and equipment necessary for the completion of concrete masonry work as indicated on the drawings and specified herein. 1.02 RELATED WORK SPECIFIED ELSEWHERE

A. Section 07180- Water Repellents B. Section 08100- Metal Door Frames C. Section 09200- Plaster D. Section 09250-Gypsum Wallboard 1.03 CODES AND STANDARDS A. Perform work with materials complying with ASTM, UBC and NCMA specifications. 1.04 INSPECTION A. Conform with the requirements of Section 01401- Testing and Inspections. 1.05 SUBMITTAL A. Submittal procedures and quantities are specified in Section 01300-Submittal. B. Submit copies of manufacturer s product information and installation instructions for each item and accessory. C. Submit samples of exposed masonry units, indicating special shapes, textures and colors. D. Expansion Joint and Control Joint Materials: Provide samples and Catalogue data. 1.06 JOB CONDITIONS Do not lay masonry when the ambient temperature is below 40 degrees F. or when it is likely that the ambient temperature will fall below 40 degrees F. during, or within 24-hours after masonry laying operations. 1.07 QUALITY ASSURANCE A. Subcontractor Qualifications: Only skilled, first class masons shall be employed for masonry work. The Masonry Subcontractor shall have a minimum of six (6) years experience in masonry work of the type indicated for this project. B. Coordination with other Trades: Coordinate masonry work with other trades that interface with the masonry work or that require penetration Through or attachment to masonry. C. Mock-Ups: Before installation of concrete masonry erect one sample panel as follows: 1. One panel shall be constructed to simulate the condition of concrete masonry walls. The panel shall be 8 feet long by 4 feet high and shall show the proposed color, texture, bond, pattern, mortar joints and workmanship for concrete masonry. Mock-up panel shall be constructed on pallets so it may be relocated as directed. 2. Upon approval by the Architect, the sample panels shall become the standard of comparison for concrete masonry construction. After concrete masonry construction has been completed, remove sample panels and dispose of debris off the site.

PART 2 PRODUCTS 2.01 CONCRETE UNIT MASONRY A. Load bearing smooth face (light, medium, normal) weight concrete masonry units shall comply with ASTM C-90-96, UBC-21-4 (Type I or Type II). Provide required shapes such as corner, end units, radius bases, bond beams, lintels, etc. Provide units open one or both ends, as required. Maximum linear shrinkage shall be.065% from standard oven dry condition. Concrete masonry units shall have a minimum net compressive strength of 1900 psi. B. Masonry units shall be manufactured by Orco Block Company, Inc., or approved equal by Architect. Provide the following types of concrete masonry units: 1. Precision block 2. Splitfaced block 3. Slump block 4. Burnished block (Factory finishing process shall remove not more than 1/16" face of block exposing aggregate and cement leaving a smooth, flat, and level face, free of saw cut or other lines marring the face of block, and match sample in Architect s Office. The use of sawing cutting block face is not acceptable.) 5. Orco Shotblast (Facory sandblasted finishing process shall remove cementitious face of block exposing aggregate and cement, leaving a medium texture to match sample in Architect s Office. The use of field sand blasting of block face is not acceptable.) 6. OrcoBurst (Variegated Block shall have factory blended colors. Manufacturing process shall blend two or more separate colors, as selected by Architect, in random proportions within blocks to produce units with the each color marbled fully and continuously throughout. The use of post applied surface stains, paints or pigments on face is not acceptable.) 7. Sound block 8. Interlocking block 9. Veneer block 10. Expandable block 11. Other (Call Your Orco Representative for expanded product list. C. Block colors shall be as follows or selected from manufacture s standard colors. 2.02 MORTAR AND GROUT COMPONENTS A. Cement: Cement shall be portland cement conforming to ASTM C-150, Type I, II, III (UBC 19-1). B. Aggregates: Aggregates for mortar conform to ASTM C-144. Aggregates for grout conform to ASTM C-404. C. Lime: Hydrated lime shall conform to ASTM C51 (UBC 21-13).

D. Water: Clean and free from deleterious substances. E. Sand: Comply with the Standard Specifications for Aggregate for Masonry Mortar, ASTM C- 144, except provide natural sand graded From coarse to fine within the following limits: Passing No. 4 sieve 100% Passing No. 8 sieve 95% to 100% Passing No. 16 sieve 70% to 100% Passing No. 30 sieve 40% to 75% Passing No. 50 sieve 10% to 35% Passing No. 100 sieve 3% to 15% F. Pea Gravel: Graded with 100% passing the 3/8" sieve and not more than 5% passing the No. 8 sieve. G. Package Materials to be delivered and stored in original packages until ready for use. Store cement, lime and aggregates in a manner which prevents deterioration or contamination. H. Do not use material which is caked, lumpy, partially set or otherwise deteriorated. 2.03 MORTAR AND GROUT MIXES A. Mortar (ASTM C-270, UBC 21-15): 1. Type S Mortar: 1 part portland cement; 1/4 to ½ part lime putty or hydrated lime; 2 1/4 to 3 times to sum of the volume of the cement and lime used. (Average compressive strength at 28 at days shall be 1800 psi.) B. Grout (ASTM C476, UBC 21-19): 1 part portland cement; 2 1/4 to 3 damp loose sand; 1 to 2 parts course aggregate. 1. Sufficient water shall be added to make a workable mix that will flow into joints of masonry without separation or segregation. When grout is to be placed in masonry units with typical rates of absorption the slump of the grout should be approximately 8 to 10 inches depending on temperature and humidity conditions. 2.04 REINFORCING STEEL A. Reinforcing bars shall comply with ASTM A615, Grade 60, except that Number 4 and smaller bars shall be Grade 40. PART 3 EXECUTION 3.01 GENERAL WORKMANSHIP A. Lay block in running bond with mortar for bed joints flattened, furrowing of bed joint mortar will not be permitted. Head joints solidly filled with mortar for a distance in from the face of the wall or unit not less than the thickness of the longitudinal face shell. Shove blocks into place to compact the head joint mortar and improve the bed joint. Vertical cells shall have vertical alignment sufficient to maintain a clear, unobstructed continuous vertical cells for grouting. Remove overhanging mortar and debris from cells before grouting. Install hollow metal frames as indicated.

B. Accurately place reinforcing steel as shown on the drawings, positively secured and supported in such a manner that no movement occurs when the grout is poured. Reinforcing and tie wires shall be embedded in the grout. The thickness of the grout between masonry units and reinforcing shall be a minimum of one bar diameter. C. Damp cure masonry work for a period of not less than 7 days after the work is completed. Make visions for curing on Saturdays, Sundays and Holidays. D. Replace defective blocks and blocks cut when cylinder is removed with new masonry which matches the existing. 3.02 JOINTS 1. Exposed vertical and horizontal joints shall be solidly filled as the work progresses. After joints are thumb print firm, they shall be tooled to a tight, smooth concave surface with an approved tool. Joint width shall be 3/8" inch, 1/2" for slump block. 2. Control of expansion joint shall be continuous through the mortar and masonry, at a maximum of 40'-0", unless shown otherwise. Horizontal reinforcement, except at roof or floor diaphragm, shall be continuous through the control joint. 3.03 CURING A. Top of grout pour should be kept damp to prevent too rapid drying during hot or drying weather and drying winds. 3.04 CLEANING A. Immediately after the wall has been fully grouted, the scum and stains which have percolated through the blocks and joints shall be hosed off with low pressure water through a jet nozzle. B. Keep area clean and neat. After completion of grouting, clean up and remove resultant debris from the site. - END OF SECTION -