CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

Similar documents
CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

OPERATIONAL PERMIT STORAGE, USE, AND DISPENSING OF LPG

Temporary Construction Heating Equipment

LIQUEFIED PETROLEUM GASES

1301: Liquefied petroleum gases.

TEMPORARY MEMBRANE STRUCTURES, TENTS AND CANOPIES Created July 2005, Revised January 2012

TENTS, CANOPIES AND OTHER MEMBRANE STRUCTURES

TENTS, CANOPIES AND OTHER MEMBRANE STRUCTURES

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

BUILDING CONSTRUCTION

TENTS CANOPIES AND OTHER MEMBRANE STRUCTURES

TENTS AND OTHER MEMBRANE STRUCTURES

NFPA 1124 (2006 Edition) Compliance List. Temporary Storage

City of Rohnert Park When Permits are Required

Pine Hill Fire District #1

TENTS AND MEMBRANE STRUCTURES

TENTS AND OTHER MEMBRANE STRUCTURES

The Notice of Drafting was published in the State Register on September 28, 2012.

TENT, CANOPY, AND TEMPORARY MEMBRANE STRUCTURE GUIDELINES

FIRE CODE REQUIRED PERMIT

City of Lorena 107-A S. Frontage Road Lorena, Texas Phone: (254) Fax: (254)

GUIDELINES FOR INSTALLATION OF ABOVEGROUND DIESEL FUEL TANKS

Village of Port Chester Building Department 222 Grace Church Street, Room 100 Port Chester, New York 10573

Bureau Policy for Tent Permit

Spray Booth Guideline

PLEASE FOLLOW INSTRUCTIONS ON PAGE FIVE

LOCAL LAWS OF THE CITY OF NEW YORK FOR THE YEAR No. 100

Temporary Emergency Housing Units October 17, 2013

SPECIAL / OUTDOOR EVENTS REQUIREMENTS

INSPECTION REQUIREMENTS Page 1 of 5. JOB SITE ADDRESS posted during entire construction process.

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

HAZARDOUS MATERIALS DECLARATION PACKET

CITY OF POMONA DEPARTMENT OF COMMUNITY DEVELOPMENT SHOW AND EXHIBITION INSPECTION

1301: Individual canopies having a maximum size of 700 square feet (65 m 2 ).

TOWNSHIP OF UPPER DEERFIELD

C-PERC Colorado Propane Education & Research Council

Fire limits--designated. All of that territory within the Village, described as follows:

The following definitions apply with regard to requirements specified in this document:

RESIDENTIAL BUILDING PERMIT INSTRUCTIONS Town of Liberty 120 North Main Street Liberty, New York 12754

MANUFACTURED HOME INSTALLATION PERMIT APPLICATION

Fredonia Guidelines for the Use of Tent/Canopy

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

BBS MEMO. Ohio Board of Building Standards August 3, Tussing Road, P.O. Box 4009, Reynoldsburg, Ohio

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

CRYOGENIC FLUIDS CHAPTER 55

SAFEGUARDS DURING CONSTRUCTION

TOWN OF ASHLAND, NEW HAMPSHIRE BUILDING REGULATIONS

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Person:

PREFACE. The Erosion and Sediment Control Ordinance and its requirements can be found at:

A BILL FOR AN ORDINANCE

RESOLUTION # l~ldian RIVER COUNtY

County of Yolo Development Services Building Inspection Division

TOWN OF GREENVILLE APPLICATION FOR PERMIT

C ITY OF D ARIEN Community Development Department 1702 Plainfield Road Phone: (630) Fax: (630)

Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2)

HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application

COMMUNITY RISK REDUCTION BUREAU MANUAL CODE REQUREMENTS TEMPORARY TENTS AND MEMBRANE STRUCTURES EFFECTIVE: APRIL 1, 2016 AUTHORIZED: R.

OHIO PROPANE GAS ASSOCIATION. Employee Training. Non-Certified

GILA RIVER FIRE DEPARTMENT REQUIREMENTS

Certificate of Occupancy Checklist:

SAFETY CODES FEES (Effective February 1, 2012)

COMMERCIAL BUILDING PERMIT

HEALTH AND SAFETY MANUAL

2015 COCM Fall Conference Act 54 #18036 Presented by Martin Van Berlo #1519 September 22, 2015

SUMMARY OF PROPOSED CHANGES KERN COUNTY FIRE CODE

CITY OF RICHMOND HEIGHTS DEPARTMENT OF BUILDING ZONING AND HOUSING STANDARDS AND REGULATIONS

Commercial Remodel Permit

Description of Work: Cost: $

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

APPLICATION FOR BUILDING PLAN APPROVAL AND PERMIT

Zoning Permits 11-1 ZONING PERMITS

Section 111 Certificate of occupancy

TEXT OF RULE. 1. Section of Part 1219 of Title 19 of the Official Compilation of Codes, Rules

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.

(C) Section 2403 Temporary tents and membrane structures

Guide to OSHA Standard Storage and Handling of Liquefied Petroleum Gases 1

Sec Amendments to the International Fire Code

CRYOGENIC FLUIDS CHAPTER 32

Building Permit Fee Schedule For Calendar Years

Building Permit Fee Schedule For Calendar Years

Cannabis Related Occupancies Commercial Building Permit Application Submittal Requirements

SPRAY BOOTH REQUIREMENTS

SPRAY BOOTH REQUIREMENTS

SUMMARY OF FIRE SPRINKLER REQUIREMENTS FOR ALTERATIONS TO EXISTING BUILDINGS 2015 I-Codes

Short title. This chapter may be cited as the "Kern County Plumbing Code."

UCC CONSTRUCTION PERMIT APPLICATION INSTRUCTIONS

Homeowners Building Permit Guide

Permit applications must be submitted in-person by the owner or their authorized agent. Subdivision Name: Phase: Lot: Block:

Phoenix Building Construction Code Updated Amendments to the Administrative Provisions

MUNICIPALITY PERMIT Issued by the City of Holyoke 63 Canal Street, Holyoke, MA Phone (413) FAX (413)

BUILDING PERMIT APPLICATION

ADDENDUM NO. 1 PRE-BID CONFERENCE: GENERAL: Great West Engineering, Inc N. Lakeharbor Lane Boise, Idaho (208)

Mason County Fireworks Permit Application

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

FENCE PERMIT APPLICATION

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street

City of Waconia. Plumber Permit Information

DATE. January 25, 2016

Transcription:

Reference: IFC, Denver Amendments, and NFPA 55, 58 Approved: Joseph L. Gonzales, Division Chief, Fire Prevention Division Page: 1 of 5 This policy is meant to provide basic information for most common conditions and situations. In any given occupancy, all other Fire Code requirements will be enforced. These will be addressed by the Fire Inspector during a premise inspection. Any questions can be addressed by the Fire Prevention Division between 6:30 a.m. and 4:30 p.m. at (720) 913-3474 or at DenFPB@DENVERGOV.ORG. You may obtain a WALK IN PERMIT between 6:30 a.m. and 9:00 a.m. ONLY, Monday-Friday at 745 West Colfax Avenue 1 st Floor. I. SCOPE The Denver Fire Department must approve the use and/or storage of LPG in advance. A permit must be issued prior to the use and/or storage. A permit is required when: one pound or more of LPG is used and/or stored at a property in the City and County of Denver (see chart on page 2). This includes LPG used on a temporary or permanent basis. Distributors shall not fill an LP gas container for which a permit is required unless a permit for installation has been issued for that location. The LPG tank/cage installer, prior to delivery of said tank or cage, must obtain an LPG Tank/Cage permit. The business/property owner, prior to delivery of LPG tank/cylinders, must obtain an LPG Use/Storage permit. II. PERMITS A permit shall be obtained from the Denver Fire Department, Fire Prevention Division. The permit shall be kept on site for inspection. To obtain a permit, the following information must be provided: Business Name, phone number, fax number, and address Contact Name, phone number, and fax number Property/business owner name, phone number, fax number, and address. Site address List the use(s) of the LPG, eg. forklift, welding, temporary heater, etc. List the number of cylinders; include the weight (in pounds) of each individual cylinder, tank. List total weight of all LPG on site; include inside and outside use and/or storage. Diagram of site location indicating LPG use/storage area.

Page: 2 of 5 Show distances from all buildings, property lines, utility poles, power lines, etc. (For storage area include distance from all building openings: windows, doors, vents, etc). Presence/absence of Code complying/functional sprinkler system To convert LPG quantities from gallons to pounds, use the following formula: Number of gallons x 4.2 = Number of pounds Example: 10 gallons x 4.2 = 42 pounds COSTS AND CONDITIONS OF PERMITS The cost of the permit is as follows: LIQUEFIED PETROLEUM GAS (LPG) PERMIT FEE 1-100 pounds - $125.00 for the first pound plus $0.75 for each additional pound or fraction thereof up to and including 100 pounds. 101 500 pounds - $200.00 for the first 100 pounds plus $0.25 for each additional pound or fraction thereof up to and including 500 pounds. 501-1500 pounds - $300.00 for the first 500 pounds plus $0.35 for each additional pound or fraction thereof up to and including 1500 pounds. 1501 and more pounds - $650.00. LP gas - storage, use and handling inside or outside of buildings in any amount requires a permit. Mushroom Heater $75 each unit single site recurring use. Make check payable to Denver Manager of Finance. Walk-in permit processing is located at 745 West Colfax Avenue,1 st Floor, Monday-Friday, 6:30 a.m. to 9:00 a.m. ONLY. Mail-in applications to 745 W. Colfax Avenue, Denver, CO 80204.

Page: 3 of 5 III. SITE INSPECTION Upon approval of LPG Use and/or Storage Permit Form, A Denver Fire Prevention Inspector will conduct a field inspection of the site. Compliance with all Fire Code requirements shall be maintained at all times. Permit shall be kept on site and posted. Permit is only valid for business/property owner, time frame, and site address indicated on the permit. A permit will be revoked if: 1. Any of the conditions or limitations set forth in the permit has been violated 2. Compliance with written order has not been achieved 3. False statements or misrepresentations of information provided in the permit application are found 4. The permit is issued in error or in violation of a City ordinance, or a Fire Code violation exists IV. GENERAL REQUIREMENTS 1. NO SMOKING and FLAMMABLE signs shall be posted and this restriction enforced. 2009 IFC 3807.2 2. A minimum 2-A-20-BC rated fire extinguisher must be within 75 feet of LPG use. 2009 IFC TABLE 906.3(2) 3. No ignition sources within 25 feet of LPG. 2009 IFC 2703.7.1 4. Piping shall be protected in an approved manner. 2009 IFC 2703.2.2 5. No storage shall be allowed within 20 feet of any opening, window, door, vent, etc. 2009 IFC 3809.4 6. No storage shall be allowed within 10 feet of building exits. 2009 IFC 3809.4 NFPA 8.4.1.1 7. Approved vehicle protection must be provided for LPG cylinders/tank. Jersey barricades must be provided for temporary LPG use. Guard posts must be provided for permanent use and shall be: (2009 IFC SECTION 312) constructed of steel not less than 4 inches in diameter and concrete-filled, spaced not more than 4 feet between posts on center, set not less than 3 feet deep in a concrete footing of not less than a 15-inch diameter, set with the top of post not less than 3 feet above ground, and located not less than 5 feet from the tank. 8. Each site shall be inspected, after cage and all required safeguards are in place, before final sign off.

Page: 4 of 5 9. If fuel dispensers are present, cage shall not be less than twenty (20) feet from fuel dispensers, and grading shall be away from cage. 2009 IFC 3809.12 10. Cage shall be constructed of metal in a manner as to allow for complete ventilation (i.e., expanded metal). NFPA 58 8.4.2.1 11. Building separation shall be determined by aggregate quantity of propane. See IFC Table 3809.12. 12. Attendant shall be the only person to remove or replace any cylinders in cages; patrons shall at no time be allowed to do the exchange. NFPA 58 7.2.2.1 13. All cylinders, whether empty or full, shall have a POL plug in place unless the cylinder is in use. NFPA 58 14. Each LPG supplier shall provide emergency phone numbers of company representatives who will respond to LPG emergency 24 hours a day, 365 days a year. This list shall be kept current at all times. NFPA 58 15. LPG suppliers shall provide all employees of each outlet with approved training as to the physical characteristics of LPG, the dangers of LPG, and emergency procedures in the event of a fire or release. NFPA 58 16. Each outlet shall have a list(s) of all trained employees available for inspection by the Fire Department. 2009 IFC 301/ Denver Amendments 17. If any of these regulations are violated, or if it is demonstrated that the exchange program presents an excessive hazard to the surrounding community, the permit shall be revoked. 18. A copy of the Emergency Procedures shall be posted in a conspicuous location. NFPA 58 Chapter 14 19. Transport of LPG containers shall comply with all pertinent DOT, Code of Federal Regulation (CFR) 49, State of Colorado regulations, and City and County of Denver ordinance. V. EXCEPTIONS: 1. Business occupancies: Portable LP-gas containers are allowed to be used to supply self contained LPG torch assemblies or similar appliances. The maximum amount of LPG is two 1 (one) pound cylinders. A LPG permit is required. 2. The installation of non-stationary or stationary LP-gas cylinders/tanks for either permanent or temporary use (e.g. heating, cooking, generator, etc.) is not allowed on any property in the City and County of Denver where natural gas is available within 300 feet of the property line.

Page: 5 of 5 LPG USE/STORAGE PERMIT APPLICATION FORM THIS FORM SHALL BE FILLED OUT AND SIGNED BY A REPRESENTATIVE OF THE SITE APPLYING FOR THE PERMIT(S). IT SHALL BE RETURNED TO THE FIRE PREVENTION DIVISION. MAKE CHECK PAYABLE TO DENVER MANAGER OF REVENUE. A PERMIT WILL NOT BE ISSUED IF THE FORM IS NOT COMPLETE AND ACCOMPANIED WITH A PLOT DIAGRAM AND FEE. NAME OF BUSINESS: BUSINESS ADDRESS: CITY, STATE, ZIP PERMIT SITE ADDRESS: DENVER, CO. ZIP CONTACT S NAME: CONTACT S PHONE NUMBER: FAX: START DATE: FEE: HOURS OF OPERATION: TO LPG TANK SIZE: INTENDED USE LPG NUMBER OF CYLINDERS/WEIGHT OF EACH CYLINDER: (e.g.,.4-33# LPG CYLINDERS TOTAL 132# LPG ON SITE PROVIDE A PLOT DIAGRAM (SKETCH OF SITE) SHOWING THE LAYOUT OF THE PROPERTY AND BUILDING. INCLUDING PROPERTY LINES, BUILDING FLOOR LAYOUT, ROADS, VEHICLE ACCESS POINTS, FIRE EXTINGUISHER LOCATION, DISPENSER (PUMP) LOCATIONS, EMERGENCY SHUTOFFS, FUEL STORAGE TANK LOCATIONS AND LP-GAS USE/STORAGE AREAS. I UNDERSTAND THAT THE DENVER FIRE PREVENTION PERSONNEL WILL CONDUCT A SITE INSPECTION, AND IF THE INSTALLATION DOES NOT COMPLY WITH THE DENVER FIRE CODE (2009 INTERNATIONAL FIRE CODE WITH CITY AMENDMENTS), THE PERMIT MAY BE REVOKED WITHOUT A REFUND. SIGNATURE: DATE: END OF DOCUMENT