Streamlining Energy Simulation To Identify Building Retrofits

Similar documents
What s My Baseline? ASHRAE

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

Energy Modeling Applications for Existing Buildings

Retrocommissioning Investigation Study of the Sheraton Chicago Hotel

ENERGY MODELING TOOLS: SOLUTIONS FOR CREATING A HIGH PERFORMANCE BUILDING. Presented by Neil Maldeis Energy Solutions Engineering Leader, Trane

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

Energy Modeling Tools Solutions for Creating an Intelligent Building

Project Information. Measure Description

National Grid USA Service Company. Impact Evaluation Of 2006 Design2000plus Custom Comprehensive Projects. Final Report

Advantages of Financing Continuous Commissioning As An Energy Conservation Retrofit Measure

Ground-Coupled Heat Pump And Energy Storage

ENSURING A PRODUCTIVE ENERGY MODELING PROCESS

9/13/2011. Mark Hanicits, Director of Facilities and Safety, MetroSouth Medical Center. Terry Malloy P.E., Cxa, Project Manager, Teng & Associates

Commercial Retro-Commissioning Program Manual for 2015 SECTION 1

Chapter 4. Analysis of Building Energy Performance

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Commercial Retro-Commissioning Program Manual for 2019 SECTION 1

Monitoring-Based Commissioning Best Practices Award Welch Hall

Leveraging Smart Meter Data & Expanding Services BY ELLEN FRANCONI, PH.D., BEMP, MEMBER ASHRAE; DAVID JUMP, PH.D., P.E.

Technical Report Two: Building and Plant Energy Analysis Report

Converting CAV to VAV in Florida: What does this really mean?

Xavier University of Louisiana

Timmins and District Hospital

SURNA Grow Facility: Systems Comparison - IEA

Measurement & Verification for Performance Contracts Through Rebuild Colorado. January Rebuild Colorado

Georgetown University New Science Center

Retro-Commissioning for Energy Efficiency

Strategies for Persistence: Measurement and Verification. Ryan Hughes PE, CEM, LEED AP Eaton Energy Solutions

City of Fort Collins Building Automation Systems Enhances Savings and Commissioning Efficiency Works Training

WAKE TECHNICAL COMMUNITY COLLEGE SUSTAINABLE ENERGY PLAN. Energy Plan

Continuous Commissioning Leading Energy Project Process - An Industry Approach

Hotels: Water and Energy

Sample Reports. for. HAP v4.80 Example Problem

Improving the efficiency, occupant comfort, and financial well-being of campus buildings

LOGO. Trivium Level II Energy Audit

equest Home Energy Model ME 514 ~ HVAC Sean Rosin University of Idaho/Boise State University Spring 2016

Success with MEASUREMENT & VERIFICATION

Deep Energy Retrofit of a HighRise MURB

LIBRARY ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

Three Case Studies of the Application of Energy Systems Optimization Best Practices for Automatic Demand Response

Recommissioning Energy Savings Persistence

Greening Buildings at the Dallas/Fort Worth International Airport. Sustainable Communities Conference Dallas, TX. March 10, 2009

Sample Reports. for. HAP v4.90 Example Problem

SCHOOL ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

TOP 10 STRATEGIES FOR NEW AND EXISTING BUILDINGS

Navigating Vermont s New Core Performance Guide. Session Overview 2/18/2008

SMART HVAC & LIGHTING SYSTEMS. Savings From Two Major C&I End Uses

Operating Engineers Seminar Bob Ford Jeff Volovsek

METHODOLOGY The process starts with a collection of available information, continued by an audit in loco, it is

Comprehensive Energy Audit For Sleetmute Water Treatment Plant

Improving Energy Retrofit Decisions by Including Uncertainty in the Energy Modelling Process

Low-Hanging Fruit Simple Steps Toward Energy Effective Building Operations

Existing Building Cx: Processes & Results A Cultural Journey. Barry Abramson Senior Vice President Servidyne

OSU Richardson and Peavy Hall Energy Study: Energy Conservation Measure Analysis. January 25, 2012 {Revised April 30, 2012}

PV Generation Potential 17.1 kbtu/ft2/yr 15.4

Retrocommissioning Investigation Report

NORTH AMERICAN MONITORING OF A HOTEL WITH ROOM SIZE GSHPS

Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001

ENERGY MODELING GUIDELINES. D. Section Building Automation and Control System Guidelines

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

For Point. Prepared For City of Nunapitchuk. June 14, 2012 ANTHC DEHE

Grunenwald Science and Technology Building

BGSU Construction Standards Office of Design & Construction Bowling Green State University

PacifiCorp Annual Review of DSM Programs California

Multifamily Net Zero Retrofit Market: Technical and Cost Benchmarks for San Francisco

Energy Assessment Report Clayville Elementary School DRAFT October George Washington Highway, Clayville, RI DRAFT

Energy Audit Baseline & Economic Analysis. Mr. Jirayut Charoenchatchai Manager,Energy Efficiency Div. Bright Management Consulting Co.,Ltd.

Energy 10/19/2011. Inc. New. Castle, DEE. Image. By: Skanska

Characteristics of Energy Consumption by building type of a U.S. Navy Installation in Hot and Humid Climate

Comprehensive Energy Audit For Chevak Vacuum Plant

Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates. Jeff S. Haberl, Ph.D., P.E.

Premium Sample Reports

how to read an energy model

Actual Energy Performance of Small Office and K-12 School Buildings Designed to Meet the 30% ASHRAE Advanced Energy Design Guides

Energy Conservation Measure Development Identify, Screen, and Analyze

Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager

OPTION 1: PERFORMANCE RATING METHOD

Southwest Texas Junior College

Indiana University Glick Eye Institute. LEED Measurement & Verification Plan

Energy Consumption Analysis and Energy Conservation Evaluation of a. Commercial Building in Shanghai

Building Load and Energy Estimates Analysis. Instructor: Dr. Mumma. October 28, Thesis Building Sponsor s: INOVA Fairfax Hospital

Energy Auditing for Schools. Maryland Energy Administration Eric Oliver, EMO Energy Solutions, LLC May 10, 2007

Deep Energy Retrofit Modeling and Cost Effectiveness Study: A Technical Policy Brief. January 2013

Energy Efficiency in Multi-Tenant Office Buildings

Greening Your Business Energy Efficiency in Buildings

MEASUREMENT AND VERIFICATION GUIDELINES FOR RETROFIT AND NEW CONSTRUCTION PROJECTS

Incentives. After work is complete:

Mechanical Tech Report 2

For. Prepared For ANTHC DEHE

Allstream Centre Energy Performance Report

MID-RISE APARTMENT BUILDING PROTOTYPE HIGH PERFORMANCE PV Genera on Poten al 10.8 kbtu/ 2/yr

Comprehensive Energy Audit For. Savoonga Water Treatment Plant

Mind the Gaps: Post-Occupancy Discoveries from Design to Operation

Comprehensive Energy Audit For Kongiganak Health Clinic

17% 2,300,000 AED. Project Case Study. Fairmont the Palm

Optimizing Energy Use in a HealthCare Setting. Michael P. Della Barba Environmental Health & Engineering, Director of Commissioning

Incorporating Uncertainty Analysis into a Building Retrofit Analysis Using OpenStudio and EnergyPlus

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

LOW-RISE APARTMENT BUILDING PROTOTYPE HIGH PERFORMANCE PV Genera on Poten al 17.9 kbtu/ 2/yr

Retro-Commissioning in Hospitals

Transcription:

This article was published in ASHRAE Journal, November 2011. Copyright 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of ASHRAE. For more information about ASHRAE Journal, visit www.ashrae.org. Streamlining Energy Simulation To Identify Building Retrofits By Aleka Pappas, P.E., Member ASHRAE; and Sue Reilly, P.E., Member ASHRAE For existing building energy retrofits, developing a streamlined and cost-effective energy modeling process is critical. The process should provide building owners with accurate and timely information at a reasonable cost to allow them to make informed decisions about implementing energy efficiency improvements. Usually, only limited resources are available for investing in energy efficiency, so it is important to rank alternatives in terms of return-on-investment to build the case for immediate and future investments in efficiency. Our firm was recently tasked with carrying out energy audit assessments for three General Services Administration (GSA) Region 3 buildings, with the work funded through the U.S. Department of Energy s National Renewable Energy Laboratory (NREL), and driven by Executive Order 13423, Strengthening Federal Environmental, Energy, and Transportation Management, part of the Energy Policy Act of 2005, and the Energy Independence and Security Act of 2007. For each building, we partnered with NREL to carry out a walk-through audit assessment. We developed a calibrated building energy model that was used to calculate annual energy cost savings for a number of energy efficiency measures (EEMs) and provided a lifecycle cost analysis for each measure. Finally, the audit assessment process, results of the analysis, and recommendations were summarized in detailed reports that provided key decision-makers with the information they needed to move forward with implementation. In this case study, we focus on one of the three buildings: the Fallon Federal Building in Baltimore (Table 1). We present a relatively quick energy audit assessment and model calibration process that resulted in investment grade calculations for a number of EEMs. The process includes calibrating a whole building annual energy model to monthly utility bills with no submetered energy use or hourly trend data available. The calibrated model was then used to About the Authors Aleka Pappas, P.E., is a building energy engineer, and Sue Reilly, P.E., is president at Group14 Engineering, Inc., in Denver. Both authors have received ASHRAE s Building Energy Modeling Professional certification. 32 ASHRAE Journal ashrae.org November 2011

Initial Energy Efficiency Measures for GSA Retrofit Project Use existing equipment for waterside economizing Reenable on-site CHW plant Turn down the heating temperature setpoint in the garage Replace perimeter FCUs with fewer larger units Intermittent control for perimeter FCUs Retrofit FCU fan motors with ECMs Bring OA rates down to Standard 62.1-2004; use extra capacity for economizer Demand-controlled ventilation where not already implemented On-site boiler plant Put two fans on the BAS to enable unoccupied shut-down Enable existing exhaust run-around loop energy recovery calculate annual energy cost savings for the EEMs. This case study gives an overview of our approach, highlighting strategies used to streamline and reduce analysis time. For some analysis details, the degree of accuracy is reduced in favor of analysis speed; a sensitivity analysis showed that this did not significantly impact final results and recommendations. Analysis Process Our premise is that the cost of the audit assessment and analysis should be considered relative to the total life-cycle value of EEMs. For a typical audit assessment, the cost of the analysis should not significantly increase the simple payback period or life-cycle net present value of recommended EEMs. For this project, the entire analysis and reporting process took just under 300 hours of work, and our consulting fees increased the calculated life-cycle value of recommended EEMs by 0.7%. This time could be further reduced through streamlined reporting. The International Performance Measurement and Verification Protocol (IPMVP 2 ) discusses the idea of balancing uncertainty with analysis cost. The Fallon Federal Building is large and has high costs of purchased steam and chilled water, so relative analysis costs were low. We focused on increasing energy modeling speed when selecting a modeling tool and developing the process. DOE-2.2 with the equest interface was selected as the most appropriate modeling tool. The ultimate goal of the modeling was to determine annual energy cost savings to calculate payback periods and life-cycle net present values for EEMs. Realizing that 10% to 20% error in energy modeling results is acceptable based on this goal allowed for a quicker and less detailed energy modeling process; a sensitivity analysis described below backs up this approach. Early in the analysis, we identified the model inputs necessary to ensure greater levels of accuracy, Optimize the reset schedule on DOA units Upgrade to enthalpy heat recovery wheel Static pressure reset control in AHUs Lower VAV box minimum airflow rates to reflect cooling loads Install lighting controls at the circuit level in section of building De-lamp some HIDs in the garage Daylighting controls in lobby Daylighting controls in perimeter offices Low-flow water fixtures Software to manage computer runtime hours at night Photovoltaic system Location Baltimore, ASHRAE Climate Zone 4A Building Parameters 735,300 ft 2 Includes 17 Above-Grade Stories and a 1.5 Story Below-Grade Parking Garage; Late 1960s Construction Space Use Mainly Office Space for Government Agencies Occupancy 1,200 People Multiple VAV AHUs on Lower Three Levels, Two-Pipe FCUs at the HVAC System Perimeter Zones in the Upper Levels, Dedicated Outside Air AHUs Provide Ventilation to the Entire Building Lighting System Mainly 4 ft T8 lamps with Electronic Ballasts Chilled Water Source Purchased at About $0.30/ton hr (2009) (Disabled On-Site Chilled Water Plant) Hot Water Source Purchased Steam at About $21.50/thousand lbs (2009) Cost of Electricity $0.121/kWh Blended Rate (2009) Table 1: Fallon Federal Building overview. which then allowed for focused efforts and reduced time spent collecting information. Data Collection The data collection process consisted of three stages: 1) collecting information before the site visit, 2) on-site information gathering, and 3) compiling and processing information into model inputs. Before the site visit, we requested three years of utility bills from the building, as-built MEP drawings, and asked about the possibility of starting trends at the building automation system (BAS) that we could later collect when on site. We were not able to obtain BAS trend data or building plans before the site visit. Involving the building staff throughout the energy audit process allowed us to gather information more quickly, and gave us invaluable insight about how the building was working and could be working. It made the process more transparent, and implementation of EEMs became more likely with initial buy-in from building staff. We planned each day of the site visit and ensured that building staff had time scheduled to help. We also had a controls expert on site to help with functional testing and obtaining data from the BAS. November 2011 ASHRAE Journal 33

Initial EEM List Developing an inclusive, but refined, list of EEMs to analyze may have been the most critical part of this process (see sidebar, Initial Energy Efficiency Measures for GSA Retrofit Project). We developed this list while still on site; this allowed us to take advantage of insight from the building staff, and get their responses to the list before we started modeling. The list served as a driver for the analysis and was refined throughout the process; it helped us determine critical model inputs and gave insight to the most appropriate model calibration approach. Using a whole building energy simulation tool with the capability of running multiple parametrics in a short period of time allowed us to work with a fairly exhaustive list of EEMs. Although we eliminated measures that were not feasible, we did include any EEM that we or the building staff thought was worth pursuing. Model Development and Calibration The calibration target for the energy model from NREL was to achieve within 10% of annual building energy cost. This is a fairly course calibration target, with thousands of different combinations of model inputs as possible solutions. We used experience, observation, and existing research to determine which inputs to vary for calibration while trying not to spend time on details that would not impact results. We first separated the list of model inputs into three categories: known values, roughly known values, and unknown values (Table 2). Figure 1: Sketch of energy model geometry. We started developing the model by incorporating all of the known and roughly known values, and inputting mid-range values for the unknowns. We incorporated simplifications whenever possible that would not significantly impact results for the list of EEMs. The building geometry and zoning was greatly simplified, resulting in a significant reduction in modeling time. We took care to model the exterior wall, roof, and window areas accurately per orientation, but grouped together surfaces whenever possible. Zoning was detailed enough to assign appropri- Known Values Source Approach HVAC Equipment Capacities, Efficiencies As-Built Drawings, Verified On Site HVAC Operating Schedules BAS, Conversations with Staff HW, CHW, AHU Setpoints BAS, Conversations with Staff Fan and Pump Peak kw Calculated From amp Readings and Nameplates Acceptable level of accuracy achieved HVAC Functional Conditions BAS, On-Site Functional Testing with collected information. These Lighting Power Densities As-Built Drawings, Verified On Site values were fixed during model Lighting Controls Conversations with Staff, Verified On Site calibration. Building Geometry Construction Documents, Verified On Site Window Geometry and Performance Cut Sheets, Verified On Site Cost of CHW, Steam, and Electricity Contracts with Utilities and Utility Bills Roughly Known Values Source Approach Ventilation Airflow Rates BAS (Damper Positions) and MEP Schedules Fixed Based on Best Estimate Wall and Roof R-Values As-Built Drawings, Unverified Fixed (Minor Impact on Results) Data Center Airflow Rates CRAC Equipment Capacities, Site Observations Fixed Based on Best Estimate Elevator Energy Use Typical Values From Published Research Fixed (Minor Energy Use) Weather TMY2 File for Baltimore See Sensitivity Analysis (Table 5) Unknown Values Source for Range Approach Plug Load Power and Schedules Experience, Occupant Density, and Publications Used for Electricity Calibration Kitchen Energy Use Typical Values and Conversations with Staff Fixed (Minor Energy Use) Building Infiltration Typical Values for Similar Buildings Used for CHW Calibration Parking Garage Infiltration Typical Values and Observations Used as a Single Variable for Steam Steam Valve Leakage Estimated Based on Observations Calibration Table 2: Summary of model inputs. 34 ASHRAE Journal ashrae.org November 2011

Advertisement formerly in this space.

ate floor area to each AHU, or group of FCUs with the same orientation, which 4,500 led to a fairly basic perimeter/core zoning pattern. The total modeling time 4,000 3,500 spent on the building geometry was 3,000 about three hours. Of equal importance, the model runtime on a 64-bit desktop computer with 2,500 2,000 an Intel Core2 Quad processor was 1,500 around 16 seconds; this allowed us to run the model repeatedly as required for error checking throughout the development 500 1,000 process. Our comfort level with these geometry simplifications stemmed in part 0 from knowing that building envelope upgrades would not fall within acceptable economic criteria for this project; our focus was on lighting and HVAC measures. 400,000 Another simplification was in using 350,000 a TMY weather file during calibration 300,000 instead of actual weather data. Resulting errors would be cancelled out during 250,000 the calibration process, and by taking 200,000 the difference of results from two models (baseline model energy cost minus 150,000 100,000 EEM model energy cost) to calculate 50,000 annual energy cost savings. As a check on this assumption, we ran the models 0 with a weather file from Atlanta, which has 36% fewer heating degree-days and 36% more cooling degree-days than Baltimore. Without going through a calibration process with this weather file, 800,000 700,000 annual energy cost savings for our final bundle of recommended EEMs changed 600,000 by 16%. As shown in the sensitivity analysis summarized below, this variance in 500,000 annual energy cost savings would change 400,000 the payback period calculation for the 300,000 bundle of EEMs by less than one year. Furthermore, if the models had been 200,000 calibrated to this new weather file, we 100,000 expect the change in results to be lower. 0 After the initial model development, the model was thoroughly checked for errors until the simulations seemed to be giving realistic results. When deciding how to calibrate this model, we considered: 1) only the unknown and roughly known values can be varied for model calibration; and 2) energy cost savings calculations for EEMs should not be strongly, if at all, dependent on values varied for calibration. We also kept in mind that energy modeling is a process that requires well thought out simplifications of the actual building; the more justified simplifications you can make, the more usable and comprehensible the model be- lbs (in thousands)/month Three-Year Average Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. Figure 2: Steam calibrated model and metered use. Ton hr/month Three-Year Average Modeled Figure 3: Chilled water calibrated model and metered use. kwh/month Modeled Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. Three-Year Average Modeled Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. Figure 4: Electricity calibrated model and metered use. comes, while still maintaining the desired level of accuracy. This leads to a process in which more time is spent in planning the analysis, and less time spent modeling. Because this building uses purchased steam for all heating loads and purchased chilled water for all cooling loads, these end-uses were effectively submetered. So, the steam (Figure 2), chilled water (Figure 3), and electricity energy (Figure 4) uses were calibrated independently; this removed a good deal 36 ASHRAE Journal ashrae.org November 2011

Advertisement formerly in this space.

of variability from the process. We arrived at a single most-rational calibration variable for each of these three energy end-uses. As shown in Table 3, the calibrated model total energy costs comply with ASHRAE Guideline 14 1 requirements for monthly normalized mean biased error (NMBE) and for coefficient of variation of the root mean squared error (CV RMSE). The steam energy use does not comply with these requirements. The NMBE is 0% for steam because positive and negative errors are cancelled out; these errors are better represented by the CV RMSE, at 33%. By another metric suggested in the IP- MVP 2, the predicted savings should be larger than twice the standard error. Our predicted savings were about 100 times the standard error. The 10% NREL annual energy cost error requirement was met, which was the stated goal for this analysis. The major unknown variables affecting steam energy use were parking garage infiltration and leakage in the steam valves serving the garage AHUs, which we knew had been significant and rather sporadic during the periods for which we had utility data. These valves had been repaired just before we arrived to do the assessment. The modeled steam Annual Error Monthly Normalized Mean Biased Error Coefficient of Variation Of the Root Mean Squared Error ASHRAE Guideline 14 ±5% 15% NREL Requirements ±10% Calibrated Model Electricity 1% 1% 4% Steam 0% 0% 33% Chilled Water 12% 13% 13% Energy Costs 5% 5% 12% Table 3: Model calibration errors. energy use was calibrated by varying the garage infiltration, with a fixed valve leakage value. This approach had the same result as if we had varied both inputs. This was the most difficult energy use to calibrate; the ground level parking garage peak infiltration rate was increased from our initial assumption of 0.007 cfm/ft 2 to 0.020 cfm/ft 2 (0.003 L/s m 2 to 0.009 L/s m 2 ) (where ft 2 is the parking garage floor area) to calibrate the steam energy use. The modeled chilled water use was very close to measured data before calibration, and was calibrated by slightly changing the building infiltration rate. The building had no air-side or water-side economizing capabilities, so there was a significant chilled water load year-round. Advertisement formerly in this space. Advertisement formerly in this space. 38 ASHRAE Journal November 2011

Advertisement formerly in this space.

Annual Electricity Savings (kwh/yr) Annual Chilled Water Savings (MMBtu/yr) Annual Steam Savings (MMBtu/yr) Annual Energy Cost Savings ($/yr) Annual O&M Cost ($/yr) Total Annual Savings ($/yr) Implementation Cost Simple Payback Period (yrs) 15-Year Life-Cycle NPV* 1,934,516 9,015 1,116 $679,830 $45,986 $633,844 $2,419,582 3.8 $4,983,059 *A nominal discount rate of 4.2%, and an energy cost escalation rate of 0.81% were used for the LC NPV calculations 5,7 Table 4: Bundle of recommended EEMs. We obtained a fairly high level of accuracy in the key HVAC and lighting inputs before starting the model; this was a major area of analysis time spent. We calculated peak fan and pump kw, and airflow and ventilation airflow rates as accurately as possible. Functional testing performed during the site visit ensured us of current operating conditions such as valve operating conditions and VFD functionality. Since most of the significant EEMs dealt with the HVAC system, we knew that reaching a high level of accuracy in these model details was most important. For the lighting system details, we used plans of recent lighting renovations and verified the actual lighting systems while on site. We chose not to spend time pursuing a high level of accuracy in determining plug loads because EEMs would not be focused on this energy use. We did propose one EEM dealing with plug loads (unoccupied hours computer management software), but we focused efforts on HVAC and lighting measures. The plug load power density would not significantly impact energy savings calculations for any of the other EEMs being considered, so this was the obvious calibration variable. We used a W/ft 2 value that was at the high end of a range of values cited in an ASHRAE Journal article 4 as a starting point for this input; the occupant density in the building was fairly high, and a quick visual assessment found a large amount of equipment such as personal printers, mini-refrigerators, fans, etc. A typical office building plug load schedule was used, adjusted for the known building schedule. After the model calibration process, current utility rates were entered, and each EEM was set up as a parametric run in the model, run cumulatively to consider synergistic effects. The list of EEMs was refined and we ended up analyzing 22 different measures. Economic Calculations The key economic metrics calculated for each EEM were simple payback period and 15-year life-cycle net present value Advertisement formerly in this space. Advertisement formerly in this space. 40 ASHRAE Journal November 2011

Key Variable Change In Key Variable Nominal Discount Rate Energy Cost Escalation Annual Energy Cost Savings ($/yr) Annual Implementation O&M Cost Cost ($/yr) Simple Payback Period (yrs) 15-Year Life- Cycle NPV Life-Cycle NPV Percent Change Baseline 4.20% 0.81% $679,800 $46,000 $2,419,600 3.8 $4,982,500 10% 4.20% 0.81% $611,820 $46,000 $2,419,600 4.3 $4,191,900 16% 20% 4.20% 0.81% $543,840 $46,000 $2,419,600 4.9 $3,401,200 32% Annual Energy Cost Savings 30% 4.20% 0.81% $475,860 $46,000 $2,419,600 5.6 $2,610,600 48% 40% 4.20% 0.81% $407,880 $46,000 $2,419,600 6.7 $1,819,900 63% 50% 4.20% 0.81% $339,900 $46,000 $2,419,600 8.2 $1,029,300 79% 10% 4.20% 0.81% $679,800 $50,600 $2,419,600 3.8 $4,932,100 1% 20% 4.20% 0.81% $679,800 $55,200 $2,419,600 3.9 $4,881,700 2% O&M Costs 30% 4.20% 0.81% $679,800 $59,800 $2,419,600 3.9 $4,831,200 3% 40% 4.20% 0.81% $679,800 $64,400 $2,419,600 3.9 $4,780,800 4% 50% 4.20% 0.81% $679,800 $69,000 $2,419,600 4.0 $4,730,400 5% 10% 4.20% 0.81% $679,800 $46,000 $2,661,560 4.2 $4,740,600 5% 20% 4.20% 0.81% $679,800 $46,000 $2,903,520 4.6 $4,498,600 10% Implementation Costs 30% 4.20% 0.81% $679,800 $46,000 $3,145,480 5.0 $4,256,700 15% 40% 4.20% 0.81% $679,800 $46,000 $3,387,440 5.3 $4,014,700 19% 50% 4.20% 0.81% $679,800 $46,000 $3,629,400 5.7 $3,772,700 24% 10% 4.62% 0.81% $679,800 $46,000 $2,419,600 3.8 $4,766,700 4% 20% 5.04% 0.81% $679,800 $46,000 $2,419,600 3.8 $4,560,000 8% Nominal Discount Rate 30% 5.46% 0.81% $679,800 $46,000 $2,419,600 3.8 $4,362,000 12% 40% 5.88% 0.81% $679,800 $46,000 $2,419,600 3.8 $4,172,300 16% 50% 6.30% 0.81% $679,800 $46,000 $2,419,600 3.8 $3,990,400 20% 10% 4.20% 0.73% $679,800 $46,000 $2,419,600 3.8 $4,935,800 1% 20% 4.20% 0.65% $679,800 $46,000 $2,419,600 3.8 $4,889,400 2% Energy Cost 30% 4.20% 0.57% $679,800 $46,000 $2,419,600 3.8 $4,843,300 3% Escalation 40% 4.20% 0.49% $679,800 $46,000 $2,419,600 3.8 $4,797,500 4% 50% 4.20% 0.41% $679,800 $46,000 $2,419,600 3.8 $4,752,100 5% 100% 4.20% 0.00% $679,800 $46,000 $2,419,600 3.8 $4,529,700 9% Table 5: EEM Bundle life-cycle net present value sensitivity analysis. (LC NPV). The simple payback period was the primary metric used to vet the feasibility of EEMs; the GSA is interested in considering EEMs with payback periods of 10 years or less. Nineteen EEMs met this criterion; these were selected to be included in a final recommended bundle of measures. Results for this bundle are shown in Table 4 (Page 40). The use of building energy modeling allowed us to quickly analyze synergistic effects of all of the EEMs together. Implementation costs were estimated using a combination of RSMeans data 6 and experience. A 30% contingency was added to all estimated costs. As shown, if implemented all together, these 19 EEMs are predicted to have a simple payback period of 3.8 years, and a 15-year life-cycle net present value of almost $5 million. The bundle is predicted to reduce the annual energy cost by 36% based on the calibrated model. Only five of the EEMs we included in our initial list were not included in the recommended bundle; the effort spent upfront in developing this list paid off in efficiency of analysis. We performed a rough sensitivity analysis similar to that discussed in the NIST Handbook 1353 3 to see the impact of error in any of our key assumptions on these results. The critical values entering into these economic calculations include: Nominal discount rate (adjusted for inflation); Energy cost escalation rate; Annual energy cost savings (from energy model); Annual O&M costs; and Implementation cost. We varied each of these five values by a range of percentages to determine the impact on payback period and life-cycle net present value calculations. The results of this analysis are detailed in Table 5. As shown, the greatest impact on results comes from varying in the annual energy cost savings. Decreasing this value by 50%, however, only increased the simple payback period by 4.4 years, which still left the final value November 2011 ASHRAE Journal 41

within the feasibility criteria of 10 years or less. We expect that the actual error in modeled energy cost savings is significantly less than 50%. Conclusions It is important to streamline a process for calibrating energy models for energy audit calculations to make the cost of analysis reasonable for a project, while still maintaining a desired level of accuracy. Modeling accuracy can be sacrificed while still obtaining sufficient accuracy in economic metrics for decision makers. Time-saving strategies that we incorporated into this process include: Plan the site visit and open communication paths with building staff to minimize time required later to gather additional information. Develop a comprehensive list of EEMs while on site, with input from the building staff. Select a modeling tool with the potential for quick implementation and runtime so that calibration can be accomplished interactively. When collecting model input data, realize which inputs are less critical and minimize time in obtaining accuracy in these values. Refer back to the initial list of EEMs for insight on what is appropriate. Simplify the energy model wherever reasonable; consider implications on time spent collecting model inputs and model runtime when adding detail. Refer to the list of EEMs for insight on what simplifications are appropriate. Using a TMY weather file when calibrating the model is likely a reasonable approach if a data file with actual weather is not readily available. Because savings are estimated between a baseline model and the EEM using the same weather data, error in a weather file is somewhat neutralized. References 1. ASHRAE Guideline 14-2002, Measurement of Energy and Demand Savings. 2. Efficiency Valuation Organization. 2010. International Performance Measurement and Verification Protocol, Volume 1. 3. Fuller, S.K., S.R. Petersen. 1995. NIST Handbook 135, Life-Cycle Costing Manual for the Federal Energy Management Program. 4. Komor, P. 1997. Space cooling demands from office plug loads. ASHRAE Journal 39(12). 5. National Institute of Standards and Technology. Energy Escalation Rate Calculator. www1.eere.energy.gov/femp/information/ download_blcc.html#eerc. 6. RSMeans. 2011. Building Construction Cost Data. 7. Rushing, A.S., J.D. Kneifel, B.C. Lippiatt. 2010. Energy Price Indices and Discount Factors for Life Cycle Cost Analysis 2010: Annual Supplement to NIST Handbook 135 and NBS Special Publication 709. Advertisement formerly in this space. 42 ASHRAE Journal November 2011

Advertisement formerly in this space.