Systems for Mӧssbauer Spectroscopy

Similar documents
Cryogenic Workstations for Nanotechnology Experiments

Cryogen Free Superconducting Magnet Systems

Measurement Probe Brochures

Vertically aligned 14 Tesla split-pair

Closed Cycle Cryostat Optical Cryostat for High cooling power and Ultra Low Vibration experiments.

Y, XY, XYZ and Sample Manipulators. MultiCentre Sample Handling Systems. MultiCentre XYZ Stages

BAR STRAIN GAGE DATA SEMICONDUCTOR BAR STRAIN GAGES DATA SHEET

ANALYTICAL STAGES. Section 10. Introduction to the MultiCentre Range of analytical stages. Configuring the MultiCentre.

Match your Inspection Ports to your Process Temperatures

Which Microstat is right for you?

CRYOGENICS OPTIONS FOR THE MMA. L. D'Addario, 97/09/20 REQUIREMENTS. We begin by assuming that the required cooling at each antenna

ION`X HV ROUND MAGNETRONS INTRODUCTION SPECIFICATIONS OPTIONS ACCESSORIES

Thermocouple Reference Table

Cryogenic sample environment on TOSCA

Bonded Neo Magnetization Guide

Reflux Samplers for Process Gas Chromatographs Their Use and The Importance of Product Design

A millikelvin cryocooler for space

Thermocouple Reference Table

Microwave Plasma Processing

D.0. Thermocouple. Introduction

Liquid & Electrical Feedthroughs

A Superconducting Magnet System for Whole-Body Metabolism Imaging

Fused Silica: Bakeout to 200 C Operating Temperature -65 C to 150 C Standard Transmission Range 0.25 to 2 microns

Machine Shut Off Nozzles. & Filtering & Mixing Nozzles. o n STANDARD TIP DESIGN

D.0. Thermocouple. Introduction

Cryogenic substrate cooling or substrate heating without vacuum feedthroughs

CRYOGENIC MATERIAL TESTING

Testing of a 1 kw-class Cryogenic Turboalternator

VELO module prototype 2

Item No.*9: 14T Cryogen Free System for measurement of physical properties:

Photoetched Regenerator for Use in a High Frequency Pulse Tube

Glass & Quartz Components

Demonstration of an Ultra-Miniature Turboalternator for Space-Borne Turbo-Brayton Cryocooler

Setting Mechanical Seals

High Temperature Probe Adapters

CRYOGENICS. MSN 506/Phys 580

Content Page OPTIC Liners OPTIC 2 OPTIC 3 OPTIC-4 LINEX PHASER

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

UNCLASSIFIED AD AMED SERVICES TECHNICAL INFORMAON AGENCY ARLINGTON HALL 87ATION A11NGf 12, VIRGINIA UNCLASSIFIED

Development of a 15 W Coaxial Pulse Tube Cooler

Electrical Resistance Monitoring

Second stage cooling from a Cryomech PT415 cooler at second stage temperatures up to 300 K with cooling on the first-stage from 0 to 250 W

Cryostat Design and Fabrication for the Gemini NIRI Instrument

Preliminary Results on a Large Acoustic-Stirling ("Pulse Tube") Cooler Designed for 800W at 70K

FFTR1821QB6A FFTR1821QM6A FFTR1821QS6A FFTR1821QW6A

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit AUT25RLD-W AUT25ALD-W

Development of a Diaphragm Stirling Cryocooler

Beam Leads. Spider bonding, a precursor of TAB with all-metal tape

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

ECE 541/ME 541 Microelectronic Fabrication Techniques

THE CRYOGENIC SYSTEM FOR THE LHC TEST STRING 2: DESIGN, COMMISSIONING AND OPERATION

Modulating liquid level regulators direct operated, for low pressure side types SV 4, 5 and 6 REFRIGERATION AND AIR CONDITIONING.

Status of Design and R&D Activities for ITER Thermal Shield

The ITER Neutral Beam Test Facility. Design Overview. European Tasks ref. TW3-THHN-IITF1 ( ) TW4-THHN-IITF2 ( ) Jean-Jacques Cordier

Large Dewar: What does it means?

3Pin and Socket Connectors

Description. Spectro Tabs, higher purity conductive carbon tabs,12mm O.D.

PLASTICS TODAY THE MAGAZINE OF PLASTICS MANUFACTURING PRODUCTIVITY

MODEL NanoMill TEM Specimen Preparation System. Ultra-low-energy, inert-gas ion source. Concentrated ion beam with scanning capabilities

Low-Cost 2G HTS Coated Conductor Scale-Up at STI

Float valves Types SV 4, SV 5 and SV 6

On the way to the latest packaging R2R Metallizer

Optional shutter. Optional shutter

TESLA TEST FACILITY (TTF) CRYOSTAT DESIGN AND DEVELOPMENT

GDMS. High Resolution GDMS.

Flat Bank SERIES 05FB AND 07FB. Options CONSTRUCTION FEATURES EQUIPMENT OPTIONS PRODUCT DATA CLEAN-LINE TM SERIES 05FB/07FB PD-CLFB-03A JANUARY 2003

Hermetic Solutions. Air Conditioning & Refrigeration Industrial. Product Information

Specialised Hydrocarbon-based Grease for Cryogenic Applications

Master of Technology (M. Tech.)

Vortex Mass Flowmeter

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

TESLA TEST FACILITY (TTF) CRYOSTAT DESIGN AND DEVELOPMENT

2008 JINST 3 S The interface to the LHC machine. Chapter Beampipe Layout

Operation of the Levitated Dipole Experiment Floating Coil

ATTACHMENTES FOR APD 2000 PRO POWDER X-RAY DIFFRACTOMETER. Monochromators

CEMS study on diluted magneto titanium oxide films prepared by pulsed laser deposition

Subsea Ball Valves 15,000 PSIG C

SURFACE TEMPERATURE SENSORS

Description Part No. Price

Ø mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGY OF SUCCESS ISO 9001

AN EXPERIMENTAL STUDY AND NUMERICAL SIMULATION OF TWO-PHASE FLOW OF CRYOGENIC FLUIDS THROUGH MICRO-CHANNEL HEAT EXCHANGER

TRACE 1300 and TRACE 1310 Gas Chromatographs Dual Detector Microfluidics Installation Guide

Measured and Calculated Performance of a High Frequency, 4 K Stage, He-3 Regenerator

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

Energy Efficiency and Recovery at Large Scale Cryogenic Plants: A Survey


Does Your Application Call for an F-Shell Heat Exchanger?

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES

B.0. Multipin Connector. Introduction

Author: Donald Pretty, Project Manager, Presenter: John Downs, Environmental Manager, B&W PGG, KVB-Enertec Products January 29, 2015

GERDA TG4 Cryogenic Vessel Status Report

CRYSTALAS. UV Optics System for Excimer Laser Based Crystallization of Thin Silicon Films

OTS BELLOWS Off-The-Shelf Welded Diaphragm Metal Bellows

SunMaxxTM Information Guide: Evacuated Tube Solar Collectors

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH Laboratory for Particle Physics RECENT DEVELOPMENTS AND QUALIFICATION OF CRYOGENIC HELIUM FLOW METERS

CF100 BAND SCREENS REDUCE MAINTENANCE COSTS & DOWNTIME... INCREASE CAPTURE RATIO & EFFICIENCY

Smardt Water Cooled Chillers

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

Thermocouple for Flue Gas Temperature Measurements,

Transcription:

Systems for Mӧssbauer Spectroscopy CRYO Industries of America, Inc.

CRYO Systems for Mӧssbauer Spectroscopy Cryo Industries of America, Inc. has numerous designs for Mӧssbauer Spectroscopy. In the most common designs, the sample is placed in exchange gas which results in ultra low vibrations at the sample! The cooling is provided by a Gifford-McMahn (GM) or pulse tube closed cycle refrigerator for long term cryogenic operation. No liquid cryogens are needed! In order to ensure that vibrations from the coldhead are not transmitted to the sample, the coldhead is isolated from the sample via a flexible bellows assembly. This flexible bellows assembly is placed between the refrigerator and a sample support flange. For additional vibration dampening the support flange is mounted to a vibration isolation stand. By working with our team of physicists and engineers, Cryo Industries is able to custom design a system that will meet all your experimental needs.

CRYO Model: REF-399-D22 CRYO s most popular system for Mӧssbauer Spectroscopy is the Top Loading Sample in Exchange Gas (REF-399-D22). This system is available with an integrated 10 K or 4 K coldhead. REF-399-D22 features exchange gas cooling of low thermal conductive samples. Samples can be changed in seconds without shutting off or warming the refrigerator. An independent sample mount heater results in fast thermal response. Ultra-stable variable temperature operation. The Model REF-399-D22 (Mossbauer) features low vibration through bellows, spacer and exchange gas isolation. A vibration isolation stand is included. All REF-399-D22 Systems Feature: Model: REF-399-D22 Vibration isolation bellows assembly Low Vibration Support Stand Exchange gas manifold Sample probe with rotational and linear adjustments T-style optical sample holder Clear type D mylar windows (0.010 thick) Heaters installed on coldhead and sample mount Silicon diode temperature sensor installed on sample mount Matching silicon diode temperature sensor installed on 2nd stage refrigerator 10-pin electrical sample feedthrough Sample exchange gas valve with safety pressure relief Evacuation valve with safety pressure relief

CRYO Model: REF-399-D22 (cont.) Pure Fe Foil 300 K, Refrigerator off FWHM = 0.252 mm/s 10 K REF System Specs: <15K to 325K operating temperature range 2 Stage (GM) coldhead Model 22-1.0 watts @ 20K 2nd stage cooling power -8.0 watts @ 77 K 1st stage cooling power CTI Model 8200 Water cooled compressor 18 K, Refrigerator on FWHM = 0.260 mm/s -12-8 -4 0 4 8 12 Velocity (mm/s) 4 K REF System Specs: Above: Fe thin foil spectra. The line widths are 0.252 at 300 K (without refrigerator) and 0.260 with refrigerator. Virtually no refrigerator induced vibrations. <5K to 325K operating temperature range 2 Stage (GM) coldhead Model SRDK 408D -0.1 watts @ 5K 2nd stage cooling power -5 watts @ 40 K 1st stage cooling power Water cooled compressor

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CRYO INDUSTRIES OF AMERICA, INC., 11124 S WILLOW STREET MANCHESTER, N.H. 03103. ANY REPRODUCTION IN PART OR WHOLE WITHOUT THE WRITTEN PERMISSION OF CRYO INDUSTRIES IS STRICTLY PROHIBITED Model: CF-2497-MOS Cryogen Free Superconducting Mӧssbauer Magnet System CRYO Cryo Industries innovative Cryogen Free Superconducting Magnet Mӧssbauer System is a true performance by design system. The system offers either a 5 Tesla magnet horizontal field split pair at 4.2 K with active null field positioned in each horizontal port or a 10 Tesla magnet with active null field positioned in the axial ports. The system can be configured to your experimental needs! Systems Features: HIGH CURRENT LEADS (1) BLANK PORT SAMPLE POSITION ADJUSTER SAMPLE POSITIONER ASS'Y WITH PROVISION FOR VIBRATION FREE EXTERNAL SUPPORT (1) 10 PIN ELECTRICAL FEEDTHROUGH 3-WAY EXCHANGE GAS VALVE WITH 0.37" DIA. TUBE ADAPTER AND NW25 FLANGE Cryogen Free Superconducting Magnet System with integrated optical variable temperature insert VIBRATION ISOLATED FLANGE PULSE TUBE REFRIGERATOR COLD HEAD B CONCENTRICITY SPACER FREE EXTERNAL SUPPORT VIBRATION ISOLATION SAFETY PRESSURE BELLOWS RELIEF B SECTION B-B PROVISION FOR T/C VACUUM GUAGE NOTE: THIS PORT IS ROTATED INTO VIEW (GAS INLET PORT FOR CONDENSING CHAMBER) 29.00 O.D. 5 Tesla magnet horizontal field split pair at 4.2 K with active null field positioned in each horizontal port (optional 10T with active null fields positioned in axial ports) 26.75 O.D. 2 K to 325 K variable temperature range 15.81 CONDENSING CHAMBER + 0.5% homogeneity over central 1 cm DSV ADJUSTABLE THERMAL LINK Stray field <600 gauss at 20 cm from center 1.75 O.D. SAMPLE TUBE COPPER SAMPLE MOUNT WITH HEATER, PROVISION FOR TEMP. SENSOR AND TAPPED HOLES FOR SAMPLE MOUNTING Ø1.62 Ø2.81 (4) window ports, parallel to the magnetic field and at right angles to the magnetic field with aluminized mylar windows 15.78 11.06 EPOXY SEALED MYLAR WINDOWS (4) SETS 90 APART SUPERCONDUCTING MAGNET HTS magnet current leads 1.0 Watt @ 4.2 K pulse tube refrigerator for magnet cooling DWG. NO. CF-2497-MOS PROPRIETARY INFORMATION CRYO INDUSTRIES of America Inc. 11124 S. Willow St., Manchester N.H. 03103 WWW.CRYOINDUSTRIES.COM TITLE: CRYOGEN FREE SUPER-CONDUCTING MAGNET SYSTEM 16.94 Water cooled compressor

Cryo Industries of America, Inc. 11124 South Willow Street Manchester, NH 03103 Ph: (603) 621-9957 Fax: (603)621-9958 E-Mail: cryo@cryoindustries.com