Document Reference Number - CL4 CL4FIRE

Similar documents
Pyroscat Duct Wrap XL

FireMaster FastWrap XL

Fire Barrier Duct Wrap 615+

FireMaster FastWrap XL

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

Product Information Sheet. FyreWrap 1.5 Duct Insulation. Introduction. Product Components. Typical Product Parameters

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

FastWrap+ 1 1 /2 Commercial Kitchen Grease Duct Air Ventilation Duct

Duct Wrap Flexible Wraps

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17

28408 Lorna Ave. Warren, MI 48092

FyreWrap Elite TM 1.5 Duct Insulation Grease Duct ASTM E2336 System

Duct Wrap 2x2 Duct Wrap 2x2+ Commercial Kitchen Grease Duct

FyreWrap Elite 1.5 Duct Insulation Air Distribution System (ADS Ducts)

Copyright 2013 IFC. All Rights Reserved. No further reproduction or distribution authorized. Any Unauthorized reproduction or distribution is a

Product Information Sheet

Product Information Sheet

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL-FIBER FIREPROOFING REPORT HOLDER: THERMAL CERAMICS, INC.

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MINERAL FIBER FIREPROOFING REPORT HOLDER: UNIFRAX I LLC

/ADF BuyLine 1632 FIREBARRIER FIRESTOP SYSTEMS

BUILDING CODE BULLETIN

CANADA SPECIFIC FIRESTOPPING REQUIREMENTS

FIRESTOPPING & SMOKE SEALS

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

FIRE STATION 55 June 14, 2010

COMMERCIAL KITCHEN HOOD GUIDELINES

City of Westerville Guide to Commercial Inspections

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

Jean Vaillancourt Fire Protection Specialist Hilti (Canada) Corp.

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

Product Information Sheet

How to modify a tested fire-rated wall to improve its STC sound rating, while maintaining its official fire-rated qualification

Enthusiastic customers We create success for our customers by Identifying their needs and providing Innovative and value adding solutions.

Fire Barrier. Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes

Standard Installation Ceiling Radiation Dampers Models: 289, RCU, L89, A89, 291, RCI, L91, A91, 293, RC4, L93, A93, 295, RDU, L95, A95, 297, RDI,

LLOYD INDUSTRIES INC. DAMPER INSTALLATION INSTRUCTIONS

SECTION FIRESTOPPING

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

SECTION FIRE RESISTIVE JOINT SYSTEMS Display hidden notes to specifier. (Don't know how? Click Here)

Product Information Sheet

The most versatile "BIG SCREEN" high efficiency fireplace!

SECTION DUCTWORK INSULATION

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

3M Fire Protection Products 3M Interam Endothermic Mat For Commercial Buildings

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

I-STUD Shaftwall System

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

A.ENVELOPE AIR SEALING

SECTION FIRESTOP SYSTEMS

Construction Standards PAGE

ICC INTERNATIONAL, MECHANICAL CODE 2012 edition

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

CERTIFICATE OF APPROVAL No CF 5073 LEMINAR AIR CONDITIONING INDUSTRIES L.L.C.

Fire Resistive Construction

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ductwork

PROJ. NO SECTION HVAC DUCT INSULATION

Cavity ShAftwall System

Division 15 INSULATION Section 15100

RATING: Consult factory for availability Consult factory for availability

FIRESTOP 101: An Introduction to Firestopping

OUTLET PUTTY PADS SPECIFICATIONS

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Protecting Penetrations in Fire Rated Construction

I-STUD Shaftwall System

3 HOUR UL CLASSIFIED CURTAIN TYPE (D)IBD230, (D)IBD430, and (D)IBD630 FIRE DAMPERS WITH INTEGRAL SLEEVES

Standard Installation

GUIDE SPECIFICATION: DUCT LINER

JOB NAME SIMULATED STILE AND RAIL MDF DOORS of 8 REVISED 03/01/11 SECTION STILE AND RAIL MDF DOORS

St. Monica Food Pantry

Fire damper frequently asked questions for ASFP

General Requirements for Mobile Homes

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

Design & Construction Standards, Revised January

(Project Location) (your firm's name)

HPW Protocol Reference Manual

3900 Dr. Greaves Rd. Kansas City, MO (816) FAX (816)

FCIA Webinar Gypsum Wall Patching

ONE SCHOOL STREET SEPTEMBER 18, 2008 GOWANDA, NEW YORK ARCH PROJECT NO

Price Single Duct Terminal Units

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

B. Qualification Data: For installers specified in Quality Assurance article.

SECTION FIBERGLASS REINFORCED PLASTIC (FRP) DOORS AND FIBERGLASS RESIN TRANSFER MOLDED DOOR FRAMES

2.5" Min. Stud or Runner. 1.5" Mineral Fiber Blanket in Cavity, If Required. Wallboard. Retaining Angle. 1" Min. Damper Sleeve on 10" centers.

DIIM & Firestopping. Firestopping Joints FCIA 2018

Common Firestop Issues in Wood Framed Commercial Construction

B. Refer to Section : Air Distribution for lined ductwork requirements.

Fire Resistive Construction Based on the 2015 IBC BIANCO Education Day August 15, 2016

Normal, Medium And High Density Fireproofing Materials

Work Order (Bid Form) Upper East Tennessee Human Development Agency

LVH-A Series Intumescent Fire Dampers Alternative Mounted Systems 1, 2 & 4 hour Fire Rating

Technical Data Sheet

Transcription:

Fire Protection Gypsum Chase Construction and Wrap Alternatives for Commercial Kitchen Exhaust Ductwork and 1 or 2-Hour Fire-Rated Ventilation Air Ductwork in Canada Document Reference Number - CL4 - Nov 2007

Forward Fire protection systems are employed to limit the spread of fire within ductwork to other locations in commercial buildings, and in the case of emergency ventilation air ductwork to externally insulate and protect the duct in order to provide the building occupants additional time to safely vacate the premises. The intention is to provide a fire rating around the ductwork, to protect the air from high temperature, fire and smoke contamination within the ductwork for a period of time as in the case of emergency ventilation air ducts, and to reduce the risk of premature structural collapse of the ductwork in the event of a fire. NFPA 96 NFPA 96 is the building code specified standard for ventilation control and fire protection of commercial cooking operations in Canada and is the document that should be referenced for all aspects of commercial kitchen grease duct installations and clearance requirements. This document is published to compliment the NFPA 96 document and provide information regarding requirements and recommendations for the construction of fire rated gypsum duct enclosures and alternate methods for clearance and space reduction around commercial kitchen grease ductwork and either 1 or 2 hour fire rated ventilation air ductwork. Hourly Rating requirements for Commercial Kitchen Grease Ductwork clearance reduction systems The Canadian ULC internal fire testing methods for clearance reduction systems around Commercial kitchen grease ductwork do not provided an hourly rating. However, per NFPA 96 this ductwork must also contain an external fire rating based on the height of the building. Whenever the ductwork requires both an internal and external fire rating, the system employed must meet both requirements. Internal Duct Fire Testing for Commercial Kitchen Exhaust Ductwork and other internal fire protection applications External Duct Fire Testing for Commercial Kitchen Exhaust Grease Ducts and 1 or 2 hour external fire rated ductwork applications Ductwork without dampers Whenever ductwork does not contain dampers at the fire rated wall or floor separation, the ducts must employ a firerated shaft or shaft alternativee to maintain the required fire resistance. CL4 November 2007 Page 1

Determining the suitability of a fire protection gypsum enclosure or alternative product for fire protecting ductwork. Gypsum shaft alternatives such as fire protection ductwrap insulation systems can be approved for use in commercial kitchen grease ductwork if it has been subjected both to the required hourly external fire testing (per NFPA 96) tested per ISO 6944 A standard and the Canadian ULC grease duct requirements. Emergency ventilation air ductwork is only required to have an ISO 6944 A external fire rating. It is important to observe the system requirements for threaded support rod diameter and spacing of hanging supports as well as firestopping requirements through fire separations. Fire rated gypsum wall assemblies are normally constructed with gypsum panels on both sides of the wall separated by structural components such as metal studs. Gypsum shafts normally require a similar assembly as a fire rated wall separation as the fire rated gypsum panels are separated by metal studs. One or more layers of fire rated gypsum are normally required on both sides of the assembly to produce the 1 or 2 hour fire rating. The space required for a fire rated gypsum shaft protecting a commercial kitchen grease duct requires an allowance for the thickness of the twosided gypsum assembly plus the additional NFPA 96 specified clearance (normally 6 ) between the duct and the inside of the limited combustible gypsum shaft. Structural integrity and the soundness of the gypsum panels are integral to the installation of a proper fire rated gypsum shaft. Fire Protection Gypsum Shaft Systems It is important to note that gypsum shaft constructions have not traditionally been fire tested for use as a fire protection ductwork shaft enclosure and determining a suitable construction for this application can often be challenging. Prior to installing this type of fire protection system it is important for the gypsum manufacturer to provide certified documentation from the approval source (often the Building Material Evaluation Commission) regarding the specific system details and installation limitations. These system details must include the type and thickness of the gypsum panels, installation and spacing details and shaft corner construction. The gypsum manufacturer must also provide fire protection structural details that are to be used for supporting the shaft. Using Fire Protection Insulation Ductwrap Systems as an alternative to gypsum shaft installations. Fire protection ductwrap insulation systems approved for Canada employ high temperature insulation materials time rated for temperatures applications of approximately 1100 Celcius. Historically, the insulation was constructed from ceramic fibre which is classified with a 2B possible carcinogen rating by the International Agency for Research on Cancer IARC. Materials now used for this application normally utilize a soluble fibre alternative that is designed to dissolve in the human body and has been assessed for safe installation by the Ontario Construction Safety Association for use under the same safety guidelines as fiberglass or mineral wool insulation. Synthetic Vitreous Fibres safety guidelines may be obtained directly from the Ontario Construction Safety Association. In order for a gypsum shaft alternative to be considered for use in Canada the product must be tested to Canadian ULC guidelines for internal and also for a 2 hour fire rating for external fire commercial grease duct applications. Ventilation air ductwork typically requires a 1 or 2 hour exterior fire rating as specified by the NFPA 96 standard. Once fire tested these applications must receive a listing approval from a Standards Council of Canada approved testing laboratory indicating that the product has been tested, what the product is approved for, and the document also CL4 November 2007 Page 2

contains a recipe for proper installation of the product. Typical Canadian approval agencies are Underwriters Laboratories of Canada ULC or cul, Warnock Hersey WH or Intertek Testing Services ITS. Listing documents also include installation details such as: Duct thickness and maximum size allowances weld pinning approvals and spacing between the pins banding type, size, thickness and spacing Duct support details including sizes and spacing between supports Special application details such as cocoon wrapping of supports or 2 and 3 sided installation details CL4 November 2007 Page 3

Installation Specification for Gypsum Shaft and Shaft Alternative Ductwrap Insulation Systems Fire rated Gypsum Shaft Installation Requirements 1. All commercial kitchen exhaust fire rated gypsum shaft installations must meet NFPA 96 guidelines for clearance between the ductwork and gypsum shaft. An exception to this requirement can be made if the gypsum system has been fire tested for application under Canadian ULC guidelines and contains a relevant for Fire Resistant Ductwork FRD listing through a Standards council of Canada approved fire testing laboratory normally ULC or WH. 2. All fire rated gypsum shaft assemblies must offer documented construction details specifically approved for the required fire protection hourly rating by the Ontario Building Material Evaluation Committee. Manufacturer s documentation shall not be considered as a substitute for these documents unless submitted for approval by the mechanical project engineer and the authority having jurisdiction. 3. Gypsum shaft support systems for supporting the ductwork and gypsum shaft must have written authorization for acceptance for the fire protection application by the gypsum manufacturer. 4. All gypsum used for fire protecting commercial kitchen exhaust ductwork or emergency ventilation air ductwork must be reviewed for soundness and be void of penetrations. Any penetrations of the shaft must be submitted to the engineer and authority having jurisdiction prior to installation. 5. All installed firestops shall be in compliance with an approved ULC S115 listed system. 6. Upon completion, the gypsum manufacturer or their designated agent shall review all fire rated gypsum shaft installations and offer written confirmation that to the best of their knowledge that the shaft is properly installed and sufficiently supported for the application. CL4 November 2007 Page 4

Installation Requirements for Fire rated FRD listed Ductwrap Insulation 1. Application of fire rated thermal insulation is required for use on commercial kitchen grease ductwork or other ductwork such as emergency ventilation air ductwork as a gypsum shaft alternative. Material shall be applied directly to the ductwork in accordance with the ULC or WH listed system and manufacturer s instructions. 2. 1 hour exterior rated installations must contain a minimum of 1 ½ thickness of minimum 6 lb density fire protection ductwrap insulation to minimize heat infiltration into the ductwork during a fire. 3. 2 hour exterior rated installations or commercial kitchen grease duct installations must contain a minimum of 3 installed thickness of minimum 6 lb density fire protection ductwrap insulation to minimize heat infiltration into the ductwork during a fire. 4. Access door openings insulation must be snugly fitted and free from overlaps or other potential sources of heat leakage around the opening perimeter. 5. Ductwrap shall be encapsulated with a tear resistant cover to ensure protection of the product during and after installation. Any damage to the product during installation shall be rectified by the installer to the satisfaction of the insulation manufacturer, engineer and authority having jurisdiction. 6. Applicable Ductwork fire rating standards are: NFPA 96 standard for Ventilation Control & Fire Protection for Cooking Operations Canadian ULC guidelines for Grease Duct Testing ISO 6944 Duct A Standard with 1 or 2 hour external duct fire rating ULC S115 95 Firestop testing standard ULC S102 for 25/50 Flame Spread & Smoke Development Rating 7. Commercial kitchen grease ductwork or 2 hour external fire rated emergency ventilation air ductwork requiring 2 layers of fire rated soluble fibre thermal insulation must be installed with staggered butted seams per listed system instructions in order to minimize heat infiltration. 8. 1 hour external fire rated emergency ventilation air ductwork requiring the use of 1 layer of firerated soluble fibre thermal insulation must be installed with overlapping seams. Overlapped seams are preferred for insulating single layer 1 hour fire rated installations to further ensure that fire & heat do not penetrate any seams. 9. All banding, weld pins, support rods and anchors must be properly sized and spaced to match the duct size per listing requirements. All banding, anchors and support rods not matching the system requirements will be removed and replaced at the installing contractor s expense. 10. Upon completion of the ductwrap installation and prior to enclosure of the ductwork, the ductwrap insulation manufacturer or their designated agent shall review all fire rated insulation ductwrap installations and offer written confirmation that to the best of their knowledge that the shaft is properly installed and sufficiently supported for the installed fire protection application. CL4 November 2007 Page 5