IMAGE II. Panel Information. Detail Conditions. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations PIM-1

Similar documents
TABLE OF CONTENTS IMAGE II. Detail Conditions. Panel Information. Flashing Profiles

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

CLIP-LOC. Panel Information. Detail Conditions. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations

Detail Conditions. Panel Information. Flashing Profiles. Notes. Accessory Profiles. Testing Information. Design/Installation Considerations PEF-1

VERTICAL SEAM TABLE OF CONTENTS

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

EVERSEAM 20 APPLICATION GUIDE

* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.

SEAM-LOC 24. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles

SHURLOC 150 STANDARD DETAILS

TRIAD CORRUGATED METAL, INC.

5V Crimp DESIGN/INSTALLATION INFORMATION

PBR & PBU PANELS. Technical/Installation Information

Stile. Spanish Tile Installation Guide

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions...3 Fastener Placement...4 Fastener Selection...5

SECTION METAL ROOF AND SOFFIT PANELS

Roofing Installation Manual: Concealed Fastener Panels Material Data, Trim Details, and Step-by-Step Instructions

PBR & PBU PANELS. Technical/Installation Information

IMPORTANT NOTICE READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE WEATHER GUARD PANEL.

TABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB

Residential Pricing Guide

SSL-175. Specifications

RESIDENTIAL LIGHT GAUGE APPLICATION GUIDE

a division of NCI Standing Seam Roof Systems

TRIAD CORRUGATED METAL, INC.

DL-200. Specifications

ABSeam Panel Overview and Installation Instructions

Central Snap. Condition Details C SNAPDETAILS

w w w. s a q u l i t y m e ta l s. c o m

TYPICAL ROOF CONDITION LAYOUT

Table of Contents. 3. Exposed Fastener Panels

900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900

HORIZON-LOC EXPOSED FASTENER TRIMS

Central Seam Plus. Central-Loc

IMPORTANT INFORMATION

Table of Contents. 3. Standing Seam Panels

PBR & PBU Panels. Technical/Installation Information

WESTERN RIB. Installation, Flashings & Shop Drawing Detail Guide.

w w w. s a q u l i t y m e ta l s. c o m

Western States 7/8 Corrugated

ML-150. w w w. s a q u l i t y m e ta l s. c o m. san antonio branch 210 W. Peden San Antonio TX P. (210) F.

Architectural Roof and Wall Products Guide Specifications

R PANEL / PBR PANEL. Installation, Flashings & Shop Drawing Detail Guide.

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Tile

CONTOUR CORRUGATED PANEL

T-Armor Install Guide

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

1.5 mechanical lock ml 150

1.5 mechanical lock ml 150

1.5 snap lock sl 150

Trusted Tested Tough Kalaeloa Blvd, Kapolei, Hawaii Phone (808) Fax (808) Neighbor Islands (800)

Central Texas Metal Roofing Supply Co., Inc 36" SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼ NET COVERAGE

Central Texas Metal Roofing Supply Co., Inc NET COVERAGE SHEET WIDTH

SECTION METAL ROOF PANELS

ML200 Panel Technical Data Guide

Central Texas Metal Roofing Supply Co., Inc 36" NET COVERAGE SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 40 ¼ 40 ¼

S BI COM P ON E NT CA T ALOG

Architectural Wall Products Guide Specifications

SL-16. Design/Installation Information

CONTINUOUS VENTILATORS

Architectural Roof and Wall Products Guide Specifications

238T Aluminum Standing Seam Metal Roof System (SSMRS)

2120 SW Poma Drive; Palm City, Florida Phone Fax

2120 SW Poma Drive; Palm City, Florida Phone Fax

Covering Design Regions

SECTION STEEL BUILDING SYSTEMS

CS-100 Guide Specifications

Prestige Series 12. Installation guide

Architectural Roof and Wall Products Guide Specifications

LokSeam. Design/Installation Information. This booklet includes: Trims and Accessories Design and Installation Information

Classic Rib Roofing Panels DETAIL MANUAL

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

Central Texas Metal Roofing Supply Co., Inc SHEET WIDTH 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼ 38 ¼ 40 ¼

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

A. Metal Building System Description: Rigid modular, with interior columns with expandable endwall.

3' COMMERCIAL RIB PREFORMED METAL SIDING

PIPE. Central Texas Largest Distributor. Structural Steel, Pipe and Metal Building Components

For Metal Roofing Systems Fascia, Mansards,& Soffits

StrongSeam SSFF1 Panel

Light-Metal Roof Edge, Raised

PRE-ENGINEERED METAL BUILDING SYSTEM

T-Rib Roofing System

1 1/2" SSR. FABRAL The pursuit of excellence since 1967

Black s Metals Installation Guide

COMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER

Guide Specification SDP 200

SHEET METAL ROOF TEST REPORT

SECTION STEEL DECKING

SECTION ROOF SPECIALTIES

SECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.

PROLOK EAVE PROLOK ROOFING PANEL ROOFING NAIL

Architectural Roof Products Guide Specifications

Residential, 26 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

SECTION ROOFING AND SIDING PANELS

SECTION STANDING SEAM METAL ROOFING

Architectural Roof Products Guide Specifications

SL175 Panel Technical Data Guide

FABRAL The pursuit of excellence since 1967

Transcription:

Table of ontents Product Page No. Product Page No. Panel Information Profiles... PIM-2 Panel Overview...PIM-2 Flashing Profiles Eave...PIM-3 Extended Eave...PIM-3 leat...pim-3 Offset leat...pim-3 5K Gutter...PIM-3 5K Gutter Endcap...PIM-3 3" Downspout...PIM-3 3" Downspout Elbow...PIM-3 2" Downspout Bracket...PIM-3 2" oil...pim-3 Valley...PIM-3 Image II Rake...PIM-3 Image II Step Rake...PIM-3 Rakewall...PIM-3 Image II Step Rakewall...PIM-3 ounter Flashing...PIM-4 Reglet Flashing...PIM-4 Step Ridge/Hip over...pim-4 3" Ridge/Hip over...pim-4 Perforated Vent Drip...PIM-4 Peak...PIM-4 Pitch Break...PIM-4.5" Sill/Head...PIM-4.5" Sill to Soffit...PIM-4 " Z-losure...PIM-4 Accessory Profiles obra Vented losure...pim-5 Outlet Tube...PIM-5 Fascia Bracket...PIM-5...PIM-5 Tape Sealant...PIM-5 Outside losure...pim-5 Rubber Roof Jack...PIM-5 Touch-Up Paint...PIM-5 Metal Panel Hemming Tool... PIM-5 Detail onditions Eave Detail...PIM-0 Eave with Offset Detail...PIM-0 5K Gutter Detail... PIM- 5K Gutter with Offset Detail... PIM- Slope hange Detail...PIM-2 Valley Detail...PIM-2 Valley with Offset leat Detail... PIM-3 Step Rake Detail...PIM-3 Rake Z-losure Detail...PIM-4 Rakewall Z-losure ounter Detail... PIM-4 Rakewall Z-losure Reglet Detail... PIM-5 Step Rakewall ounter Detail... PIM-5 Step Rakewall Reglet Detail... PIM-6 Endwall Z-losure ounter Detail... PIM-6 Endwall Z-losure Reglet Detail... PIM-7 Endwall Foam-losure ounter Detail... PIM-7 Endwall Foam-losure Reglet Detail... PIM-8 Peak Z-losure Detail...PIM-8 Peak Foam-losure Detail... PIM-9 Ridge/Hip over Detail...PIM-9 Vented Ridge (obra Vent) Detail... PIM-20 Vented Ridge (Perforated Vent Drip) Detail... PIM-20 Testing Information UL 263 Fire Resistance Ratings... PIM-6 Section Properties and General Information... PIM-7 Design/Installation onsiderations Fastener Installation Technique... PIM-8 ondition of Substructure... PIM-8 Ventilation...PIM-9 Panel Applications...PIM-9 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-

Panel Overview PANEL PROFILES With Striations 2" overage " With Striations " 6" overage With Minor Ribs " With Minor Ribs " 2" overage 6" overage SLOPE SUBSTRATE OVERAGE LENGTH AVAILABILITY APPLIATION PERFORMANE TEST FASTENING SYSTEM FASTENERS MATERIALS FINISH The minimum recommended slope for any Image II roofing panel is 3:2. The recommended substrate is 5 /8" plywood with a 30 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure. Please note that Image II panels are not recommended for use over open framing. Image II panels are available in a 2" and 6" widths with a " rib height. panel length is 5'-0". Maximum recommended panel length is 30'-0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult your Metal Sales branch for recommendations (see PGI-2 and 3 for locations). Image II panels material gauges and finishes vary. Please refer to the Image II brochure/color chart. Applications include residential and architectural buildings ranging from new construction to retrofit. The term retrofit as applied to construction methods is to replace or rework. UL 228, UL790, UL263, ASTM E-592 oncealed direct fastening system using Truss Head Woodscrews applied through factory punched fastening slots/groove into wood decking. Fastener spacing is 8" on center, except where extreame wind uplift conditions exist. The fastener selection guide should be consulted for choosing proper fasteners for specific applications. Quantity and type of fastener must meet necessary loading and code requirements (see PGI-2-3). Steel, minimum grade 50 * Acrylic oated Galvalume (AG) / ASTM A 792 Prepainted Galvanized / ASTM A 792 ** PVDF Fluorocarbon * Differential appearance of Acrylic oated Galvalume roofing materials is not a cause for rejection. ** Meets both Kynar 500 and Hylar 5000 specifications. PIM-2 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

Flashing Profiles EAVE EXTENDED EAVE LEAT 3 7 /8" X* 3" Hem Length 0'-2" - *Specify Slope Angle 5 /8" 6" /2" X* 3" 5 /8" Length 0'-2" - *Specify Slope Angle 2 /2" 35 /2" Length 0'-2" OFFSET LEAT 5K GUTTER 5K GUTTER ENDAP /2" " /2" Length 0'-2" 3" DOWNSPOUT Length 20'-6" 3" DOWNSPOUT ELBOW 2" DOWNSPOUT BRAKET 2" 29 Gauge - Length 0'-3" Style "A" Style "B" 2" OIL VALLEY RAKE (For ontinuous Gutters) 3 /2" X* 2" 0" 4" 6" Inside Diameter Length 50'-0" Length 0'-2", 20'-3" - *Specify Slope Angle Length 0'-2", 20'-3" 5 /8" 3 /8" STEP RAKE 2 7 /8" RAKEWALL STEP RAKEWALL " Hem /8" 4" 3 /2" 4" 4" /8" Hem Hem Length 0'-2", 20'-3" 5 /8" Length 0'-2" Hem 2 7 /8" Length 0'-2" " Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-3

Flashing Profiles (cont.) OUNTER FLASHING REGLET FLASHING STEP RIDGE/HIP OVER 5 /8" " 3 /4" 2" " /2" /2" X* 3 /2" Hem /2" 3 /4" Length 0'-2" Hem Length 0'-2" Length 0'-2" - *Specify Slope Angle 3" RIDGE/HIP OVER 5 /2" " X* " Length 0'-2", 20'-3" - *Specify Slope Angle PERFORATED VENT DRIP /4" 3 /4" 60 20 PEAK 3 /4".032 Aluminum 3 /8" Linen White Only Length 0'-2" Length 0'-2", 20'-3" - *Specify Slope Angle 5" X* 6" PITH BREAK.5" SILL/HEAD.5" SILL TO SOFFIT 6" X* 4" 2 /2" " /2" /2" 3 /8" 2 /2" /2" 4 3 /4" /2" Length 0'-2" - *Specify Slope Angle Length 0'-2" Length 0'-2" " Z-LOSURE " " - Indicates color side of flashing. " Length 0'-2" PIM-4 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

Accessory Profiles OBRA VENTED LOSURE OUTLET TUBE 2" X 3" FAIA BRAKET 36" TUBE SEALANT TAPE SEALANT OUTSIDE LOSURE 36" 0.3 oz. artridge Urethane 7 /8" X 3 /6" X 25' Double Bead Butyl - Gray " RUBBER ROOF JAK TOUH-UP PAINT METAL PANEL HEMMING TOOL MINI ( /4" to /8" O.D. Pipe) #2 ( 3 /4" to 3" O.D. Pipe) #4 (3" to 6" O.D. Pipe) #6 (6" to 9" O.D. Pipe) #8 (7" to 3" O.D. Pipe) Available in pints PVDF / MS olorfast45 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-5

UL 263 Fire Resistance Ratings Metal Roof Deck Panels Metal Sales Manufacturing orporation has obtained fire resistance ratings for various products conducted according to test criteria set forth by 'Underwriters Laboratories' "Standard Fire Tests of Building onstruction and Material" (ANSI/UL 263). This test procedure is identical to ASTM E-9 and NFPA 25. The fire resistance rating is for the total assembly and not just the external metal panel. Ratings are expressed in hours and vary depending upon the assemblies. In general, the test criteria is to evaluate the assembly's ability to continue to support the superimposed loads and resist the passage of flame, high temperatures, or hot gases which will ignite combustible materials. The test assemblies are identified by an alpha-numeric design number. For detail information on specific assemblies and hourly ratings see UL Fire Resistance Directory. METAL SALES MFG ORP R9697 Mechanically attached metal roof panels - Type Image II For use in Design Nos. P224, P225, P227, P230, P237, P508, P50, P52, P70, P7, P72, P73, P75, P77, P720, P722, P723, P724, P726, P73, P734, P736, P803, P84, P85, P88, P89, P82, P823, P824. *Hat shaped member to be a minimum of 6 gauge. The member will be fastened through the roof insulation to the steel roof deck with min. No. 4 self-drilling and/or self-tapping fasteners. Spacing to be determined by the structural loading requirements. In addition any compressible UL lassified glass fiber blanket insulation with or without a vapor retarder facing may be used between the specified roof insulation and the metal roof panels. **Bearing plate to be a minimum of 6 gauge. Member will be fastened through the roof insulation to the steel deck with min. No. 4 self-drilling and/or self-tapping fasteners. See the UL Fire Resistance Directory for explanation of each design number listed above. U L Underwriters Laboratories Inc. LISTED PIM-6 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

Section Properties and General Information 2" 2" overage Striations " 6" 6" overage Striations " 2" " 6" " 2" overage Minor Ribs 6" overage Minor Ribs Ga. Width in Yield ksi SETION PROPERTIES Weight psf Top In ompression Bottom In ompression Ixx in 4 /ft Sxx in 3 /ft Ixx in 4 /ft ALLOWABLE UNIFORM LOADS psf (3 or More Equal Spans) Outward Sxx Load in 3 /ft 0'-6" '-0" '-3" '-6" '-9" 2'-0" 26 6" 80 0.90 0.057 0.068 0.063 0.075 86 7 64 56 46 42 24 6" 50.9 0.020 0.0226 0.020 0.0226 86 7 64 56 46 42. Theoretical section properties have been calculated per AISI 200 Specification for the Design of old-formed Steel Structural Members with 2004 Supplement. Ixx and Sxx are effective section properties for deflection and bending. 2. Allowable load is calculated in accordance with AISI 200 specifications considering bending, shear, combined bending and shear, deflection, testing, fastener pullout from 5/8" plywood, and pullover. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling. Panel weight is not considered. 3. Deflection consideration is limited by a maximum deflection ratio of L/80 of span. 4. Allowable loads do not include a /3 stress increase in uplift. GENERAL INFORMATION ATTAHMENT DETAIL #0-2x" PH Woodscrew Slope The minimum recommended slope for the Image II roof panel is 3:2. Substructure Image II is designed to be utilized over a solid substrate. To avoid panel distortion use a properly aligned and uniform substructure. NOTE: Image II roof panels are not recommended for use over open structural framing. overage Image II panels are available in a " seam height with a 2" or 6" width coverage. FASTENING PATTERN Length factory cut length is 5'-0". Maximum recommended panel length is 30'-0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult Metal Sales for recommendations. Fasteners The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading and code requirements. NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment. Availability Finishes: Acrylic oated Galvalume, MS olorfast45, or various Kynar 500 (PVDF) colors. Gauge: 26 ga standard, 24 ga optional Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-7

Design / Installation onsiderations FASTENER INSTALLATION TEHNIQUE Recommended Tool Type - Use depth locating nose or adjustable clutch on screw gun to prevent overdrilling and strip out. Do not use impact tools or runners. Seating the washer - Apply sufficient torque to seat the washer - do not overdrive the fastener. ORRET Sealing material slightly visible at edge of metal washer. Assembly is watertight. TOO LOOSE Sealing material is not visible; not enough compression to seal properly. TOO TIGHT Metal washer deformed; sealing material pressed beyond washer edge. WOODSREW To prevent wobbling - Make sure fastener head is completely engaged in the socket. If the head does not go all the way in the socket - tap the magnet deeper into the socket to allow full head engagement. Metal chips will build up from drilling and should be removed from time to time. Protect drill point - Push only hard enough on the screw gun to engage clutch. This prevents excess friction and burn out of the drill point. orrect pressure will allow screw to drill and tap without binding. Drilling through sheet and insulation - Ease up on pressure when drilling through insulation to avoid striking the purlin or girt with the point - apply more pressure after drill point contacts purlin or girt. Drilling through purlin overlaps - Drilling through lapped purlins requires extra care. Excessive voids between purlins sometimes damages drill points and two self-drillers might be necessary to complete the operation. It is sometimes advantageous to predrill. ONDITION OF SUBSTRUTURE Whether over solid substrate or open structural framing, panel distortion may occur if not applied over properly aligned and uniform substructure. The installer should check the roof deck for squareness before installing Image II panels. Several methods can be used to verify squareness of the structure for proper installation of the panels. METHOD "A" - One method for checking the roof for squareness is to measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension. METHOD "B" - The 3-4-5 triangle system may also be used. To use this system measure a point from the corner along the edge of the roof at a module of three (3). Measure a point from the same corner along another edge at a module of four (4). Then by measuring diagonally between the two points established, the dimension should be exactly a module of five (5) to have a square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square, the roof system cannot be installed as shown in these instructions. METHOD A 30 30 5 3 4 METHOD B PIM-8 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

Design / Installation onsiderations (cont) VENTILATION Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency. ondensation occurs when moisture laden air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique with metal roofing; these problems are common to all types of construction. The underside of the metal roof on a typical Architectural building should be protected from condensation by installing panels directly over a minimum 30 lb moisture barrier and uniform solid substrate. This reduces airspace and the potential of condensation forming on the underside of the panels. Vent Vent Insulation Vent at wall Vent at eave Typical metal building (no attic) Building with attic or retrofitted PANEL APPLIATIONS The following chart highlights UL 580 lass 90 for clip installation on the selected applications (see Fastener Selection Guide page PGI-2-4 for other fasteners available). For more information on UL onstruction numbers, refer to UL Roofing Materials and System Directories. Panel gauges and clip spacing should be determined by a professional engineer according to the governing building code. PANEL TYPE APPLIATION INSTALLATION REQUIREMENTS FASTENER SPAING *TYPE OF FASTENER NUMBER REQUIRED OVER 5 /8" WOOD DEK AND METAL DEK Standard 26 GAUGE 8" o.c. ALL YOUR METAL SALES BRANH FOR ASTM-E592 UPLIFT VALUE * Subject to project loading, closer fastener spacing may be required. ontact your local Metal Sales branch representative for more information (see pages PGI-2-3). Fastener spacing is based on maximum uplift suction load of 32 psf. BEARING PLATE Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-9

Eave Detail 3:2 Slope #9-5 x " Woodscrew (4 per panel) Eave #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) leat AUTION 3:2 Slope Eave with Offset Detail #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) Offset leat Eave #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) leat Panel rib must be field notched and flat part of panel must be field bent to accept offset cleat (see Architectural Manual). PIM-0 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

5K Gutter Detail 3:2 Slope #9-5 x " Woodscrew (4 per panel) Eave Fascia Bracket #9-5 x " Woodscrew ('-0" o.c.) 5K Gutter (by others) AUTION 5K Gutter with Offset Detail 3:2 Slope #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) Offset leat Eave Fascia Bracket 5K Gutter (by others) #9-5 x " Woodscrew ('-0" o.c.) Panel rib must be field notched and flat part of panel must be field bent to accept offset cleat (see Architectural Manual). Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-

Slope hange Detail 3:2 Slope #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) Offset leat Pitch Break #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) /8" x 3 /6" Pop-Rivet (3 per panel) Z-losure 3" Note: Z-losures must be field cut and bent to fit between panel ribs (see Architectural Manual). Panel rib must be field notched and flat part of panel must be field bent to accept offset cleat (see Architectural Manual). Valley Detail 3:2 Slope #9-5 x " Woodscrew (4 per panel) Valley 3" AUTION PIM-2 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

Valley with Offset leat Detail 3:2 Slope Offset leat #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) Valley 3" Panel rib must be field notched and flat part of panel must be field bent to accept offset cleat (see Architectural Manual). Step Rake Detail 3:2 Slope #9-5 x " Woodscrew ('-0" o.c.) (field cut and bend) Image II Step Rake #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) leat Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-3

Rake with Z-losure Detail /8" x 3 /6" Pop-Rivet ('-0" o.c.) Z-losure (field cut and bend) #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) Rake leat Rakewall with Z-losure (ounter) Detail Fasteners (by others) ounter Flashing Rakewall /8" x 3 /6" Pop-Rivet ('-0" o.c.) Z-losure #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) PIM-4 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

Rakewall with Z-losure (Reglet) Detail Reglet Flashing Fasteners (by others) Rakewall /8" x 3 /6" Pop-Rivet ('-0" o.c.) Z-losure #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) Step Rakewall (ounter) Detail Fasteners (by others) ounter Flashing Image II Step Rakewall #9-5 x " Woodscrew ('-0" o.c.) Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-5

Step Rakewall (Reglet) Detail Reglet Flashing Fasteners (by others) Image II Step Rakewall (field cut and bend) #9-5 x " Woodscrew ('-0" o.c.) Endwall with Z-losure (ounter) Detail Fasteners (by others) ounter Flashing Pitch Break #8-8 x 3 /4" Truss Head Woodscrew (4 per panel) /8" x 3 /6" Pop-Rivet (3 per panel) Z-losure Note: Z-losures must be field cut and bent to fit between panel ribs (see Architectural Manual). AUTION PIM-6 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

3:2 Slope Endwall with Z-losure (Reglet) Detail Fasteners (by others) Reglet Flashing Pitch Break #8-8 x 3 /4" Truss Head Woodscrew (4 per panel) /8" x 3 /6" Pop-Rivet (3 per panel) Z-losure Note: Z-losures must be field cut and bent to fit between panel ribs (see Architectural Manual). AUTION 3:2 Slope Endwall with Foam-losure (ounter) Detail Fasteners (by others) ounter Flashing Pitch Break /8" x 3 /6" Pop-Rivet ('-0" o.c.) Image II Outside losure AUTION Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-7

3:2 Slope Endwall with Foam-losure (Reglet) Detail Fasteners (by others) Reglet Flashing Pitch Break /8" x 3 /6" Pop-Rivet (every rib) Image II Outside losure AUTION 3:2 Slope Peak with Z-losure Detail /8" x 3 /6" Pop-Rivet (3 per panel) #8-8 x 3 /4" Truss Head Woodscrew (4 per panel) Z-losure Peak #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) leat Note: Z-losures must be field cut and bent to fit between panel ribs (see Architectural Manual). AUTION PIM-8 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com

3:2 Slope Peak with Foam-losure Detail /8" x 3 /6" Pop-Rivet (every rib) Image II Outside losure Peak #8-8 x 3 /4" Truss Head Woodscrew ('-0" o.c.) leat AUTION 3:2 Slope Ridge/Hip over Detail /8" x 3 /6" Pop-Rivet (3 per panel) Z-losure #8-8 x 3 /4" Truss Head Woodscrew (4 per panel) 0" Step Ridge/Hip over AUTION Note: Z-losures must be field cut and bent to fit between panel ribs (see Architectural Manual). Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com PIM-9

Vented Ridge (obra Vent) Detail 3:2 Slope /8" x 3 /6" Pop-Rivet (every rib) obra Vented losure 3" Step Ridge/Hip over AUTION 2" Max 3:2 Slope Vented Ridge (Perforated Vent Drip) Detail /8" x 3 /6" Pop-Rivet ('-0" o.c.) Perforated Vent Drip 3" Step Ridge/Hip over /8" x 3 /6" Pop-Rivet (every rib) Image II Outside losure AUTION 2" Max PIM-20 Metal Sales Manufacturing orporation/ Subject to change without notice/ Effective Date 9/ 800.406.7387 (orporate Office) www.metalsales.us.com