VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

Similar documents
VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

OPTIMASS 7400 Technical Datasheet

VersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet. Specification. The superior solution. Highlights. Applications.

OPTIMASS 7400 Technical Datasheet

VersaFlow Coriolis 6000 Sensor for Mass Flow Specifications

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

Micro Motion TA-Series Flow and Density Meters

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

ALTOFLUX IFS 4000/4005

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Coriolis Mass Flowmeter serving thousands of worldwide applications

The perfect fit for tight spaces

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Micro Motion LNG Series Meters

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

METAL & DUAL SEATED PISTON VALVES

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

VESSEL & REACTOR VALVES. VR Series RISING DISC PROCESS VALVES. Sold by: G&W Industrial Sales

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

VESSEL & REACTOR VALVES. VD Series DISC VALVES PROCESS VALVES

I/A Series Coriolis Mass Flow and Density Meters for Standard and 3A Sanitary Applications Models CFS10 and CFS20 Mass Flowtubes

Micro Motion H-Series Hygienic Mass, Density, and Volume Meter

Micro Motion Technical Overview and Specification Summary. Product Data Sheet PS-00232, Rev W January 2019

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

OPTIMASS Sensor for mass flow

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Coriolis Mass Flow Meter

Pressure transducers DMU 02 Vario (flush)

RHM 100. Coriolis Mass Flowmeter for High Flow Applications. Applications. Features. Advantages

Flow Measurement SITRANS F M

SECTION Coriolis Mass Flow Meters

METAL SEATED BUTTERFLY VALVES

CALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

FLOMID FX Electromagnetic Flowmeter

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Process Inline Filter, Change-Over

Proline Added Values Simply clever. Proline in industries Innovative products for your business

THERMOWELL ASSEMBLIES & THERMOWELLS INDEX

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Diaphragm seal with threaded connection Threaded design Model

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

Tuffy II Liquid Level Controls with Electric Switches

Large Flange Connections Specification Type LF

DATA SHEET MS2500_EN-IT_DS006REV14

DATA SHEET MS2500_EN-IT_DS006REV17

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

VLM10 In-line Vortex Mass Flow Meter

Target Inline Flowmeter

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)

Ball Float Steam Trap UNA 45, UNA 46, UNA 46A PN 40/Class 300 DN 15, 20, 25, 40, 50, 65

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)

H250 M40. The modular variable area flowmeter

Diaphragm seal with flange connection Cell-type with extended diaphragm Model

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Micro Motion Technical Overview and Specification Summary

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

94130 Pressure Relief Vent (Open or Closed Vent Option) Features

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

VERIS Accelabar. Superior Flow Measurement Accuracy

TURBINE METER RQ Series 1 and 2

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

Digital E3 Modulevel Liquid Level Displacer Transmitter

Thermometer in stainless steel with vertical stem in stainless steel

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Fractional Pressure Gauge Heavy Duty Pressure Gauge Homogenizer Pressure Gauge High Accuracy Pressure Transmitter Homogenizer Pressure Transmitter

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

SECTION Inline ULTRASONIC FLOW METERS

TRICOR Series TCM Coriolis Mass Flow Meters

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

HTM series. The Helical Turbine Meter for Custody Transfer Application

94110 Vacuum Vent. Features. Vacuum Vent. Less need for special materials in corrosive and extreme temperature

Coriolis Mass Flow Measurement System promass 63

Battery-Powered Magnetic Flow Meter

Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series

Thermometer in stainless steel with adjustable stem in stainless steel. Compression fitting for direct mounting or mounting in separate thermowell

Type Type 2000 Transducers. I/P & E/P Transducers

Diaphragm seal with flange connection With internal diaphragm Model

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates

Presented By. NicolScales.com Contact Us

L-DENS 7000 DENSITY SENSOR SERIES

MAGFLO. Flow metering based on electromagnetic technology. For value-adding performance you can count on. FLOW DIVISION Simply Better

SECTION CORIOLIS MASS FLOW MEASURING SYSTEM

Transcription:

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications 34-VF-03-12 June 2011 The Solution for Bulk Mass Flow Measurement The VersaFlow Coriolis 200 has been developed to meet the demanding transfer requirements of the oil and gas industry. It is well suited to bulk measurement in many applications. A high level of performance makes the VersaFlow Coriolis 200 suitable for the bulk measurement of petroleum and oil as well as products like syrup, molasses and raw chemicals. Combined with the power of the TWC9000, the VersaFlow Coriolis 200 will provide accurate measurement of mass, volume, density and concentration. Features Innovative twin measuring tube design Figure 1 VersaFlow Coriolis 200 sensor for mass flow High flow rate capacity Easily drained and easy to clean Optional heating jacket High accuracy for custody transfer Optimized flow divider for minimum pressure drop Modular electronics concept: electronics and sensor are easy to replace Large tube size for bulk measurement 1. Comprehensive diagnostic capabilities 2. Available with a range of process connections 3. Outer casing in stainless steel 304L or 316L 4. Common electronics across the range of sensors with redundant storage of calibration and sensor data 5. Modular electronics with all output options. Industries Oil &Gas Applications Bulk loading/unloading Chemical Custody transfer for volume and mass Paper &Pulp High Volume Food &Beverage Pipeline measurement applications Pharmaceutical Fresh water Waste water

VersaFlow Coriolis 200 Sensor for Mass Flow 2 Features and Options Features VersaFlow Coriolis 200 provides the best solution for a variety of applications where bulk measurement is required Flow rates up to 2,300,000 kg/h Integrated electronics Best in class for zero stability Connection Options The VersaFlow Coriolis 200 range of meters are available with both hygienic and flange connections. Standard flanges with ratings up to 1500 lbs. Hygienic connections (S100 only) for bulk measurement in the food/beverage industry Heating Jacket & Purge Port VersaFlow Coriolis 200 is available with both heating jacket and purge port options. Heating jacket option for use with temperature dependant products. Prevents solidification of process product. Purge port option for protection in the event of measuring tube failure. Allows hazardous chemicals to be drained away safely Can also be used for the early detection of measuring tube failure where highly toxic chemicals are being measured.

VersaFlow Coriolis 200 Sensor for Mass Flow 3 Versions Compact VersaFlow Coriolis 200 compact provides high accuracy with easy installation. Pre-programmed TWC9000 for plug &play installation. available with certified TWC9000 housing for use in hazardous areas. Stainless Steel option for TWC9000 housing for use in aggressive environments Remote VersaFlow Coriolis 200 remote version for use with either the TWC9000 F, TWC9000 W or TWC9000 R converter. Suited to applications where data collection needs to be centralized. Allows the TWC9000 converter to be installed in a safe area. 300m maximum distance between meter and converter. Stainless steel option for junction box housing for use in aggressive environments. TWC010 VersaFlow Coriolis 200 is also available with the TWC010 MODBUS communications option. Stand alone meter - operates without the TWC9000 converter. Provides industry standard MODBUS communication. Easy integration with MODBUS skids.

VersaFlow Coriolis 200 Sensor for Mass Flow 4 Outer Cylinder Please Note Honeywell strongly recommends that the burst disk option is ordered where the meter is being used to measure: high pressure gases gases kept as liquids at high pressure and/or where there is a risk of tube failure because of: the use corrosive and/or erosive process pressure and/or temperature shocking seismic or other shock loading If in doubt please contact Honeywell Field Solutions. Please note that meters ordered with flange rating of 100 barg or above, will automatically be supplied with a burst disk in the outer cylinder.

VersaFlow Coriolis 200 Sensor for Mass Flow 5 Technical data Operating Data Size S100 S150 S250 Flow Rates Maximum (kg/h) 420,000 900,000 2,300,000 Maximum (lbs/min) 14,698 33,804 84,510 Minimum (kg/h) 11,000 25,000 60,000 Custody Transfer (Mass) Custody Transfer (Volume-Operating Density 1000kg/m 3 ) Minimum (lbs/min) 404 919 2205 Maximum (kg/h) 220,000 500,000 1,200,000 Maximum (lbs/min) 8084 18,372 44,092 Minimum (m 3 /h) 11 25 60 Minimum (bbl/day) 1660 3774 9057 Maximum (m 3 /h) 220 500 1200 Maximum (bbl/day) 33,210 75,478 181,150 Measuring System Measuring principle Application range Measured values Calculated values Design Basic Features Variants Compact version Remote version Modbus version Coriolis mass flow Mass flow and density measurement of fluids, gases and solids Mass, density, temperature Volume, referred density, concentration, velocity System consists of a measuring sensor and a converter to process the output signal Fully welded maintenance free sensor with dual-straight measuring tube Integral converter Available with field, wall or 19" rack mount versions of the converter Sensor with integral electronics providing Modbus output for connection to a PLC Accuracy Mass Liquid Gas Repeatability Zero stability S100 S150 S250 ±0.1% of actual measured flow rate + zero stability ±0.5% of actual measured flow rate + zero stability Better than 0.05% plus zero stability (includes the combined effects of repeatability, linearity and hysteresis) < 7 kg/h < 18 kg/h < 50 kg/h

VersaFlow Coriolis 200 Sensor for Mass Flow 6 Reference conditions Product Temperature Operating pressure Water +20 C / +68 F 1 barg / 14.5 psig Effect on sensor zero point caused by a shift in process temperature Stainless Steel 0.0004% per 1 C / 0.000022% per 1 F Effect on sensor zero point caused by a shift in process pressure Stainless Steel 0.0002% of the max flow rate per 1 barrel. / 0.0000014% of the max flow rate per 1 psig Density Measuring range 400...3000 kg/m 3 / 25...187 lbs/ft 3 Accuracy ±2 kg/m 3 / ±0.13 lbs/ft 3 (stainless steel DN15: ±5 kg/m 3 / ±0.33 lbs/ft 3 ) On site calibration ±0.5 kg/m 3 / ±0.033 lbs/ft 3 Temperature Accuracy ±1 C / ±1.8 F Ambient temperature Compact version with Aluminium converter Compact version with Stainless Steel converter Remote versions -40...+60 C / -40 +140 F Extended temperature range: 65 C / 149 F for some I/O options. For more information contact manufacturer. -40...+55 C / -40 +130 F -40...+65 C / -40 +149 F Process temperature Flanged connection Hygienic connection (S100 only) -45 +130 C / -49 +266 F -20 +130 C / -4 +266 F Nominal pressure at 20 C / 68 F Measuring tube Duplex UNS S31803 Super Duplex UNS S32750 FM -1 140 barg / -14.5 2030 psig -1 140 barg / -14.5 2030 psig CRN / ASME B31.3-1 100 barg / -14.5 1450 psig -1 130 barg / -14.5 1885 psig Outer cylinder Non CRN approved Typical burst pressure > 100 barg / 1450 psig at 20 C / 68 F Effect on sensor zero point caused by a shift in process temperature Stainless Steel 0.0004% per 1 C / 0.000022% per 1 F Effect on sensor zero point caused by a shift in process pressure Stainless Steel 0.0002% of the max flow rate per 1 barrel. / 0.0000014% of the max flow rate per 1 psig Fluid properties Permissible physical condition Liquids, gases, slurries

VersaFlow Coriolis 200 Sensor for Mass Flow 7 Permissible gas content (volume) Permissible solid content (volume) Protection category (acc. to EN 60529) Installation conditions Inlet runs Outlet runs Contact manufacturer for information. Contact manufacturer for information. IP 67, NEMA 4X None required None required Materials Measuring tube Stainless Steel UNS S31803 (1.4462) Optional UNS S32750 (1.4410) Spigot Stainless Steel UNS J92205 (1.4470) Optional UNS J93404 (1.4469) Flanges Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified Optional Stainless Steel UNS S31803 (1.4462) (NACE approved) Optional UNS S32750 (1.4410) (NACE approved) Outer cylinder Stainless Steel AISI 304 / 304L (1.4301 / 1.4307) dual certified Optional Stainless Steel AISI 316 / 316L (1.4401 / 1.4404) dual certified Optional Stainless Steel UNS S31803 (1.4462) (1) Heating jacket version Heating jacket Stainless Steel 316L (1.4404) Note: the outer cylinder is in contact with the heating medium All versions Sensor electronics housing Stainless Steel 316L (1.4409). Optional Stainless Steel (1.4469) Junction box (remote version) Die cast Aluminium (polyurethane coating) Process Connections Flange DIN DN100 300 / PN16 160 ASME 4...12" / ASME 150 1500 JIS 100A / 10...20K Hygienic (S100 only) Tri-clover 4" Tri-clamp DIN 32676 DN100 Tri-clamp ISO 2852 4" DIN 11864-2 Form A DN100 Male thread DIN 11851 DN100 Male thread SMS 4" Male thread IDF / ISS 4" Male thread RJT 4" (1) Where this option is ordered, ther electronics stem material is UNS J92205 (1.4470) Electrical Connections Electrical connections For full details, including: power supply, power consumption etc., see technical data for the relevant converter.

VersaFlow Coriolis 200 Sensor for Mass Flow 8 I/O For full details of I/O options, including data streams and protocols, see technical data for the relevant converter. Approvals Mechanical Electromagnetic compatibility (EMC) Namur NE 21/5.95 acc. to CE 2004/108/EC (EMC) 2006/95/EC (Low Voltage Directive) Factory Mutual / CSA Class I, Div 1 groups A, B, C, D Class II, Div 1 groups E, F, G Class III, Div 1 hazardous areas Class I, Div 2 groups A, B, C, D Class II, Div 2 groups F, G Class III, Div 2 hazardous areas ANSI / CSA (Dual Seal) 12.27.901-2003 Hygienic 3A 28-03 ASME BPE Custody Transfer (pending) MID 2004/22/EC MI-005 ATEX (acc. 94/9/EC) Coriolis 200 with TWC9000C non Ex i Signal outputs Ex d connection compartment II 2 G Ex d [ib] IIC T6...T1 II 2 D Ex td A21 IP6x T160 C Ex e connection compartment II 2 G Ex de [ib] IIC T6...T1 II 2 D Ex td A21 IP6x T160 C Coriolis 200 with TWC9000C Ex i signal outputs Ex d connection compartment II 2(1) G Ex d [ia/ib] IIC T6...T1 II 2(1) D Ex td [iad] A21 IP6x T160 C Ex e connection compartment II 2(1) G Ex de [ia/ib] IIC T6...T1 II 2(1) D Ex td [iad] A21 IP6x T160 C Coriolis 200 with TWC010 II 2 G Ex ib IIC T6 T1 II 2 D Ex ibd 21 T165 C

VersaFlow Coriolis 200 Sensor for Mass Flow 9 ATEX (acc. 94/9/EC) temperature limits Coriolis 200 with TWC010 with or without heating jacket / insulation Coriolis 200 with TWC9000C Aluminium converter housing - with or without heating jacket / insulation Coriolis 200 with TWC9000C Stainless Steel converter housing - with or without heating jacket / insulation Ambient temp. Tamb C (1) depending on I/O option. Please call for more information. 40 65 40 Max. medium temp. Tm C Temp. class 65 T6 T80 75 T5 T95 110 T4 T130 130 T3-T1 T150 75 T5 T95 110 T4 T130 130 T3-T1 T150 50 T6 T80 65 T5 T95 100 T4 T130 130 T3-T1 T160 50 65 T5 T95 100 T4-T1 T130 60 60 T4-T1 T90 65 (1) 65 T5 T95 40 50 50 T6 T80 65 T5 T95 100 T4 T130 120 T3-T1 T150 65 T5 T95 75 T4-T1 T130 55 55 T5-T1 T85 Max. surface temp. C Maximum End Loadings S100 S150 S250 Flanges 20 C 40 barg 150kN 650kN 550kN 100 barg 100kN 120kN 60kN 130 C 150 barg 32 barg 150kN 280kN 400kN 80 barg 60kN 50kN 50kN 115 barg Hygienic (all connections) 130 C 10 barg 5kN - -

VersaFlow Coriolis 200 Sensor for Mass Flow 10 Measuring Accuracy Measuring Error The measuring error is obtained from the combined effects of accuracy and zero stability. Reference Conditions Product Temperature Operating pressure Water +20 C / +68 F 1 barg / 14.5 psig Dimensions and Weights Weights Weights (Kg) S100 S150 S250 Compact with aluminum converter 84.8 211.5 444.5 Compact with stainless steel converter 90.1 216.8 449.8 Remote with aluminum junction box 80.8 207.5 440.5 Remote with stainless steel junction box 81.7 208.4 441.4 Weights (lbs) S100 S150 S250 Compact with aluminum converter 187 466 980 Compact with stainless steel converter 198 478 991 Remote with aluminum junction box 178 457 971 Remote with stainless steel junction box 180 459 973

VersaFlow Coriolis 200 Sensor for Mass Flow 11 Dimensions (mm) Flanged Versions Measuring Tube in Stainless Steel Dimensions mm (inches) S100 S150 S250 A 219 ±5 (8.6 ±0.2) 323 ±5 (12.7 ±0.2) 406 ±5 (16 ±0.2) C1 (compact) 370 ±5 (14.6 ±0.2) 422 ±5 (16.6 ±0.2) 463 ±5 (18.2 ±0.2) C2 (remote) 293 ±5 (11.5 ±0.2) 345 ±5 (13.6 ±0.2) 386 ±5 (15.2 ±0.2) D 160 (6.3) E 60 (2.4) F 123.5 (4.9) G 137 (5.4) H 98.5 (3.9)

VersaFlow Coriolis 200 Sensor for Mass Flow 12 Flanged Connections PN40 DN100 1310 (51.6) Dimension B mm (inches) S100 S150 S250 DN150 1330 (52.6) 1621 (64) DN200 1647 (65.5) DN250 2030 (80.7) DN300 2050 (82.3) PN63 DN100 1336 (53.2) DN150 1370 (55.5) 1661 (67) DN200 1691 (65) DN250 2070 (84.8) DN300 2100 (81.5) PN100 DN100 1360 (53.9) DN150 1410 (55.5) 1701 (66.6) DN200 1731 (68.3) DN250 1977 (83.5) DN300 2160 (85.9) ASME 150 4 1334 (52.5) 6 1358 (53.4) 1649 (65) 8 1675 (66) 10 2024 (80.4) 12 2050 (81.5) ASME 300 4 1352 (53.2) 6 1378 (54.2) 1669 (65.8) 8 1695 (66.8) 10 2056 (81.7) 12 2082 (82.7) ASME 600 4 1398 (54.9) 6 1428 (56.1) 1719 (67.8) 8 1428 (69) 10 2138 (85) 12 2146 (85.2) ASME 900 4 1422 (55.2) 6 1474 (57.9) 1765 (69.5) 8 1474 (71.2) 10 2202 (87.5) 12 2234 (88.7) JIS 10K 100A 1332 (52.5) JIS 20K 100A 1332 (52.5)

VersaFlow Coriolis 200 Sensor for Mass Flow 13 Hygienic Versions Hygienic Connections: All Welded Versions Dimension B mm (inches) S100 S150 S250 Tri-clover 4 1223 (48) Tri-clamp DIN 32676 DN100 1236 (48.7) Tri-clamp ISO 2852 4 1223 (48) DIN 11864-2 Form A DN100 1296 (51) Hygienic Connections: Adapter Versions (male thread) Dimension B mm (inches) S100 S150 S250 Male thread DIN 11851 DN100 1288 (50.1) Male thread SMS 4 1236 (48.7) Male thread IDF/ISS 4 1223 (48) Male thread RJT 4 1234 (48.6)

VersaFlow Coriolis 200 Sensor for Mass Flow 14 Heating Jacket Version Dimensions mm (inches) S100 S150 S250 Heating connection size 25 mm (ERMETO) 1" (NPTF) A 254 ±2.5 (10 ±0.1) 355 ±2.5 (14 ±0.1) 444 ±2.5 (17.5 ±0.06) B 178 ±2.0 (7 ±0.08) 228 ±2.0 (9 ±0.08) 208 ±2.0 (8.2 ±0.08) C 28 ±2.0 (1.1 ±0.08) 28 ±2.0 (1.1 ±0.08) 6.5 ±2.0 (0.25 ±0.08) Purge Port Option Dimensions mm (inches) S100 S150 S250 A 70 ±1.0 (2.75 ±0.04) 100 ±1.0 (4.0 ±0.04) B 70 ±1.0 (2.75 ±0.04) 100 ±1.0 (4.0 ±0.04)

VersaFlow Coriolis 200 Sensor for Mass Flow 15 Guidelines for Maximum Operating Pressure Notes: Ensure that the meter is used within its operating limits All hygienic process connections have a maximum operating rating of 10 barg at 130 C/ 145 C at 266 F 1. Measuring tube [UNS S32750] PED certification 2. Measuring tube [UNS S31803] PED certification 3. Measuring tube [UNS S31803/S32750] FM certification 4. Measuring tube [UNS S31803] CRN certification Linear de-rating of PED certified secondary containment Outer cylinder material -45 C 20 C 130 C 304 /L or 316 /L 40 barg 40 barg 32 barg UNS S31803 150 barg 150 barg 100 barg Outer cylinder material -49 F 68 F 266 F 304 /L or 316 /L 580 psig 580 psig 464 psig UNS S31803 2175 psig 2175 psig 1450 psig Flanges DIN flange ratings are based on EN 1092-1 2007 table G.1 material group 14EO. ASME flange ratings are based on ASME B16.5 2003 table 2 material group 2.2 JIS flange ratings are based on JIS 2220: 2001 table 1 division 1 material group 022a Notes The maximum operating pressure will be either the flange rating or the measuring tube rating. WHICHEVER IS THE LOWER! The manufacturer recommends that the seals are replaced at regular intervals. This will maintain the hygienic integrity of the connection.

VersaFlow Coriolis 200 Sensor for Mass Flow 16 Specifications are subject to change without notice. For More Information Learn more about how Honeywell s VersaFlow Coriolis 200 Sensor for Mass Flow is well suited for bulk measurement in many applications, visit our website www.honeywell.com/ps/hfs or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps 34-VF-03-12 June 2011 2010 Honeywell International Inc.