AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: BUILDERS ACCESSORIES, INC.

Similar documents
TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: WASHOE EQUIPMENT, INC. DBA SUNOPTICS PRISMATIC SKYLIGHTS

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: ALUMIL US. SERIES/MODEL: M300 Falcon PRODUCT TYPE: Aluminum Horizontal Sliding Window (XO)

TEST REPORT. Report No.: A Rendered to: DEALERS SUPPLY AND LUMBER CO., LLC Greenville, South Carolina

INTERNATIONAL WINDOW TEST REPORT

TEST REPORT. Report No.: B Rendered to: MI WINDOWS AND DOORS, INC. Gratz, Pennsylvania

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. Rendered to: EARTHWISE GROUP, LLC Liberty Township, Ohio

Structural Performance Certification Authorization Report

Architectural Testing TEST REPORT. Rendered to: COEUR D'ALENE WINDOW Spokane Valley, Washington. PRODUCT TYPE: PVC Fixed Window SERIES/MODEL: 3310

TEST REPORT. Report No.: F Rendered to: MI WINDOWS AND DOORS, LLC Gratz, Pennsylvania

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

TEST REPORT. ASSOCIATED MATERIALS, INCORPORATED Cuyahoga Falls, Ohio. Rendered to: PRODUCT TYPE: Fixed Window SERIES/MODEL: A780 SPECIFICATIONS:

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Structural Performance Certification Authorization Report

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Structural Performance Certification Authorization Report

Structural Performance Certification Authorization Report

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

Dennis Fassnacht Jr :59:35-04'00'

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

TEST REPORT. Report No.: A Rendered to: TUBELITE, INC. Walker, Michigan

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A AAMA TEST REPORT SUMMARY

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT SUMMARY. Rendered to:

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America Inc. SERIES/MODEL: VCM/VCE B PRODUCT TYPE: Venting Curb Mounted Skylight

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: FLEETWOOD WINDOWS & DOORS. SERIES/MODEL: Norwood 3070HI OOX PRODUCT TYPE: Sliding Glass Door

PERFORMANCE TEST REPORT. Rendered to: ALL-WEATHER INSULATED PANELS. SERIES/MODEL: SM40 PRODUCT TYPE: Insulated Sandwich Wall Panel

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: MGM WINDOW COMPANY Hendersonville, Tennessee

PERFORMANCE TEST REPORT. Report No.: H Rendered to: VELUX America LLC Greenwood, South Carolina

ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC

AAMA 506 TEST REPORT. Report No.: G Rendered to: VEKA INC. Fombell, Pennsylvania

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Report No.: B Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC Marshall, Arkansas. Cycles 2,000,000. Summary of Results

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

ETC Laboratories Measuring Up To Your Standards And More

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: COASTAL INNOVATIVE PRODUCTS

AAMA/WDMA/CSA 101/I.S.2/A440-08

TEST REPORT. Rendered to: All Weather Insulated Panels Vacaville, California. PRODUCT TYPE: Roofing Panels SERIES/MODEL: SR Series

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America LLC. SERIES/MODEL: FCM B PRODUCT TYPE: Fixed Glass Glazed Curb Mount Skylight

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

MOCK-UP TEST REPORT. Rendered to: TUBELITE INC. PROJECT: 300 ES Interior Glazed Curtain Wall

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX AMERICA INC. SERIES/MODEL: CAP-1 PRODUCT TYPE: Fixed Acrylic Glazed Skylight

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: LEED HIMMEL INDUSTRIES, INC. Hamden, Connecticut

OSHA FALL PROTECTION TEST REPORT. Rendered to: SERIES/MODEL: FS S PRODUCT TYPE: Fixed Deck Mounted Skylight

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: BRICK-IT. SERIES/MODEL: Brick Veneer Panel Systems PRODUCT TYPE: Wall Panel Systems

TEST REPORT. Rendered to: ALL WEATHER INSULATED PANELS Vacaville, California. PRODUCT TYPE: Wall Panels SERIES/MODEL: DM45 Series

TEST REPORT. Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

STRUCTURAL PERFORMANCE TEST REPORT. Series Casement (Rep/Impact/AAMA) C-C70 940mm x 1930mm (37 x 76 )

AAMA 1801 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 420/430/440. TYPE: Sliding Glass Door

TEST REPORT. Report No.: B Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, LLC. SERIES/MODEL: 1650 Polyvinyl Chloride (PVC)

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: C.R. LAURENCE CO., INC. SERIES/MODEL: S80 Monterey. TYPE: Bi-fold Door

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

AAMA/WDMA/CSA 101/I.S.2/A440-08

TEST REPORT. Report No.: F Rendered to: FAIRFIELD METAL, LLC Fairfield, New Jersey

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: GAMCO CORPORATION. SERIES/MODEL: W250C Awning TYPE: Projecting (Awning)

Construction Consulting Laboratory, International

H R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: CUSTOM VINYL PRODUCTS, LLC SERIES/MODEL: SHA4. TYPE: Single Hung Window

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door with Impact Glass

TEST REPORT. Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

G R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: MI WINDOWS AND DOORS, LLC. SERIES/MODEL: 1650 Vinyl

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: ALL SEASONS DOOR & WINDOW, MFG SERIES/MODEL: A500. TYPE: Double Hung Window

TEST REPORT. Report No.: F Rendered to: VELUX America LLC Greenwood, South Carolina

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 6/8 Sliding Patio Door

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 390. TYPE: Sliding Glass Door

TEST REPORT. Rendered to: AD SKYLIGHTS, INC. Algonquin, Illinois. AD Skylight without Guard


ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 900 Series. TYPE: Out-swing Double Terrace Door

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

TEST REPORT ASTM E331. Report No.: E Rendered to: IMISON USA Houston, Texas

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: GAMCO CORPORATION. SERIES/MODEL: Curtain Wall TYPE: Glazed Wall Systems (Site-built)

AAMA 1801 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 185/3185 SP. TYPE: Picture Window

TEST REPORT. Report No.: F Rendered to: ALTECH PANEL SYSTEMS, LLC Cartersville, Georgia

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Classic-Craft, Fiber Classic, and Smooth Star

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

SECTION VINYL (PVC) WINDOWS

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: MGM INDUSTRIES. SERIES/MODEL: 4600 Double Hung

Awning Windows Tuscany Vinyl Replacement Window

Casement Windows Montecito New Construction Window

Awning Windows Montecito New Construction Window

TEST REPORT. Rendered to: KEYLINK FENCING & RAILING, INC. For: PRODUCT: Lancaster Series. TYPE: Aluminum Level Guardrail System

Intertek NAFS-11 Testing

TEST REPORT. Report No.: H Rendered to: GEORGIA-PACIFIC WOOD PRODUCTS, LLC Atlanta, Georgia

7520 Casement Windows

AAMAIWDMAlCSA S.2/ A "NAFS - North American Fenestration Standard/Specification for Windows, Doors and Skylights."

Casement Windows Tuscany Vinyl Replacement Window

SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

TEST REPORT. Rendered to: COLLINS LIMITED, LLC. For:

CR LAURENCE CO, INC. ACOUSTICAL PERFORMANCE TEST REPORT

Heavy Commercial / Architectural Projected Windows Series L900T AW150

Transcription:

AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT Rendered to: BUILDERS ACCESSORIES, INC. SERIES/MODEL: 6490 PRODUCT TYPE: Polyvinyl Chloride (PVC) Casement Window Title Summary of Results Primary Product Designator C-C30 800 x 1499 (32 x 59) Design Pressure ±1440 Pa (±30.08 psf) Operating Force (in motion) 17 N (3.8 lbf) Air Infiltration 0.05 L/s/m 2 (0.01 cfm/ft 2 ) Water Penetration Resistance Test Pressure 580 Pa (12.11 psf) Uniform Load Structural Test Pressure ±2160 Pa (±45.11 psf) Forced Entry Resistance Grade 10 Test Completion Date: 04/26/10 Reference must be made to Report No. 99077.01-301-44, dated 05/18/10 for complete test specimen description and data. 2524 E. Jensen Ave Fresno, CA 93706 phone: 559-233-8705 fax: 559-233-8360 www.archtest.com

AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT Rendered to: BULDERS ACCESSORIES, INC. 550 West Southern Avenue #101 Tempe, Arizona 85282-4506 Report No.: 99077.01-301-44 Test Dates: 03/08/10 Through: 04/26/10 Report Date: 05/18/10 Expiration Date: 04/26/14 Project Summary: Architectural Testing, Inc. was contracted by Builders Accessories, Inc. to perform testing on a Series/Model 6490, Polyvinyl Chloride (PVC) Casement Window. The sample tested successfully met the performance requirements for a C-C30 800 x 1499 (32 x 59) rating. Test specimen description and results are reported herein. The sample was provided by the client. Test Specification: The test specimen was evaluated in accordance with AAMA/WDMA/CSA 101/I.S.2/A440-05, Standard/Specification for Windows, Doors, and Unit Skylights. Test Specimen Description: Series/Model: 6490 Product Type: Polyvinyl Chloride (PVC) Casement Window Overall Size: 800 mm (31-1/2") wide by 1499 mm (59") high Vent Size: 679 mm (26-3/4") wide by 1378 mm (54-1/4") high Overall Area: 1.20 m 2 (12.91 ft 2 ) Finish: All PVC was white Frame Construction: All members were constructed of extruded PVC. The corners were mitered and fully welded. Vent Construction: All members were constructed of extruded PVC. The corners were mitered and fully welded. 2524 E. Jensen Ave Fresno, CA 93706 phone: 559-233-8705 fax: 559-233-8360 www.archtest.com

99077.01-301-44 Page 2 of 7 Test Specimen Description: (Continued) Weatherstripping: Description Quantity Location Wrapped foam gasket 3 Rows All members of vent. Glazing Details: The window utilized 7/16" thick overall sealed insulating glass. The insulating glass was comprised of two 1/8" thick clear annealed sheets with an aluminum Butyl composite (A8) spacer system. The glass was exterior glazed onto a 3/8" wide x 1/16" tall glazing tape and secured with a snap-in extruded PVC glazing bead. Drainage: No drainage was utilized. Hardware: Description Quantity Location Hinges (part# 14.97.00.005) 2 Head and sill at hinge jamb secured to the vent with four #8 x 3/4" Phillips flat head screws and to the frame with four #6 x 1/2" Phillips flat head screws. Three Point Lock Assembly 1 Lock jamb with plastic guides 16- (part# 11917.92 / 45300) 3/4", 29-1/4", 39-1/2" and 44-1/4" from sill secured with two #8 x 3/4" Phillips flat head screws each. Lock Handle (part# 24.33.32.002) 1 9" from sill secured to through lock jamb of frame with two 10-24 x 9/16" Phillips pan head screws. Keepers (part# 41129.92) 3 11-1/2", 23-1/2" and 40-1/4" from bottom rail on lock stile of vent secured with two M4 x 1/2" Phillips flat head screws each.

99077.01-301-44 Page 3 of 7 Test Specimen Description: (Continued) Hardware: (Continued) Description Quantity Location Rotor operator (part# 50.50.32.012) 1 10-1/2" from hinge jamb on sill secured to frame with eight #8 x 3/4" Phillips flat head screws and to the vent with three 8-32 x 3/4" slotted oval head bolt with 1/2" sex nuts and three #8 x 3/4" Phillips flat head screws. Snubbers (part# 6301) 6 9-1/4" from each and end and midspan on hinge stile of vent and opposite on frame secured with two #8 x 3/4" Phillips flat head screws each. Reinforcement: No reinforcement was utilized. Installation: The window was installed into a 2 x 10 test buck constructed of Douglas Fir No. 2 lumber. The nailing fin was set against the test buck and secured using #6 x 1-5/8" drywall screws located 3" from each corner and 16" on center. The rough opening was 1/8" wider and a 1/2" taller than the window. The nailing fin was sealed to the test buck with silicone.

99077.01-301-44 Page 4 of 7 Test Results: The temperature during testing was 16-23 C (60-73 F). The results are tabulated as follows: Paragraph Title of Test - Test Method Results Allowed 5.3.1 Operating Force per ASTM E 2068 Open Initiate motion 17 N (3.8 lbf) Report Only Maintain motion 17 N (3.8 lbf) 45 N (10.1 lbf) Latches 59 N (13.3 lbf) 100 N (22.5 lbf) Close Initiate motion 26 N (5.9 lbf) Report Only Maintain motion 13 N (3.0 lbf) 45 N (10.1 lbf) Latches 85 N (19.0 lbf) 100 N (22.5 lbf) 5.3.2.1 Air Leakage Resistance per ASTM E 283 75 Pa (1.57 psf) 0.05 L/s/m 2 1.5 L/s/m 2 (0.01 cfm/ft 2 ) (0.3 cfm/ft 2 ) max. Note #1: The tested specimen meets (or exceeds) the performance levels specified in AAMA/WDMA/CSA 101/I.S.2/A440-05 for air leakage resistance. 5.3.3.2 Water Penetration Resistance per ASTM E 547 and E 331 See Note #2 Note #2: The client opted to start at a pressure higher than the minimum required. Those results are listed under "Optional Performance". 5.3.4.2 Uniform Load Deflection per ASTM E 330 (Deflections were taken on the top rail of vent) (Loads were held for 10 seconds) 1440 Pa (30.08 psf) (positive) 1.5 mm (0.06") See Note #3 1440 Pa (30.08 psf) (negative) 3.0 mm (0.12") See Note #3 Note #3: The deflections reported are not limited by AAMA/WDMA/CSA 101/I.S.2/A440-05 for this product designation. The deflection data is recorded in this report for special code compliance and information only. 5.3.4.3 Uniform Load Structural per ASTM E 330 (Permanent sets were taken on the top rail of vent)) (Loads were held for 10 seconds) 2160 Pa (45.11 psf) (positive) 0.3 mm (0.01") 2.1 mm (0.08") max. 2160 Pa (45.11 psf) (negative) 0.5 mm (0.02") 2.1 mm (0.08") max.

99077.01-301-44 Page 5 of 7 Test Results: (Continued) Paragraph Title of Test - Test Method Results Allowed 5.3.5 Forced Entry Resistance per ASTM F 588 Type: B Grade: 10 Disassembly Test No entry No entry Test B1 No entry No entry Test B2 No entry No entry Test B3 No entry No entry Sash/Panel Manipulation Test No entry No entry Lock Hardware Manipulation Test No entry No entry 5.3.6.2 Thermoplastic Corner Weld Test Meets as stated Meets as stated 5.3.6.4.3 Sash Vertical Deflection Test 270 N (60.7 lbf) 2.5 mm (0.10") 13.5 mm (0.53") max. 5.3.6.6.2 Distributed Load Test 300 Pa (6.27 psf) No damage No damage Optional Performance 4.4.2.6 Water Penetration Resistance per ASTM E 547 and E 331 580 Pa (12.11 psf) No leakage No leakage Tape and film were used to seal against air leakage during structural testing. In our opinion, the tape and film did not influence the results of the test. Drawing Reference: The test specimen drawings have been reviewed by Architectural Testing and are representative of the test specimen reported herein. List of Official Observers: Name David Douglass Mason Kelly Company Architectural Testing Inc. Architectural Testing Inc.

99077.01-301-44 Page 6 of 7 Detailed drawings, data sheets, representative samples of test specimens, a copy of this report, or other pertinent project documentation will be retained by Architectural Testing, Inc. for a period of four years from the original test date. At the end of this retention period, such materials shall be discarded without notice and the service life of this report will expire. Results obtained are tested values and were secured by using the designated test methods. If test specimen contains glazing, no conclusions of any kind regarding the adequacy or inadequacy of the glass in the test specimen can be made. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Architectural Testing, Inc. For ARCHITECTURAL TESTING, INC. Jeffrey T. Osugi Technician Leaton Kirk Director-Regional Operations JO: ms Attachments (pages): This report is complete only when all attachments listed are included. Appendix-A: Alteration Addendum (1) Appendix-B: Test Equipment (1) Appendix-C: Drawings (6)

99077.01-301-44 Page 7 of 7 Revision Log Rev. # Date Page(s) Revision(s) 0 05/18/10 N/A Original report issue This report produced from controlled document template ATI 00159, revised 03/05/09.

99097.01-301-44 Appendix A Alteration Addendum Alteration #1: Date-03/25/10 Cause for alteration- Failed uniform load test. Remedial action taken- Snubber changed from Truth (Part# 31496.92) to Mikron (part# 6301). Operator screws changed to sex nuts and bolts. Alteration #2: Date-04/26/10 Cause for alteration- Failed distributed load test. Remedial action taken- Operator changed from Truth split single arm to dual arm.

99077.01-301-44 Appendix B Test Equipment

99077.01-301-44 Instrument Manufacturer Asset # Torque Wrench CDI C000494 Operating force gauge Chatillon 005698 Control Panel ATI 005724 Spray Rack ATI 004047 Linear Transducer Celesco 005283 Linear Transducer Celesco 004488 Linear Transducer Celesco 003428 Control Panel ATI 005062 Spring Scale Pelouze 004499 Bench Scale My Weigh C62323 Dial Indicator Starrett 62008 MULE (mini) ATI 005722 Load Cell 1K Interface 005135

99077.01-301-44 Appendix C Drawings