SECTION RESIDENTIAL ELEVATOR. (Freedom Green Residential Elevator)

Similar documents
SECTION RESIDENTIAL ELEVATOR. (Freedom Elite Residential Elevator)

Division 16 Sections for electrical service for elevators to and including disconnect and fused switches at machine room.

RESIDENTIAL. Legacy PLANNING GUIDE

ELVORON STELLA HOME ELEVATOR

Savaria Eclipse Home Elevator

Residential Elevator Design Guide

SECTION VERTICAL WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

ELVORON LU/LA ELEVATOR

SECTION HYDRAULIC DRIVE MACHINE ROOM (MR) RESIDENTIAL ELEVATORS

Introduction. Disclaimer. Table of contents

Residential Elevators

Planning Guide for Limited Use/Limited Application Elevator

Roped Hydraulic Residential Elevator Planning Guide

SERENUS LULA PLANNING GUIDE

SECTION The specification section is organized by placing information in three standard parts:

Introduction. Disclaimer. Table of contents

Savaria Eclipse Home Elevator OPTIONS. In business for over 30 years, Savaria designs,

Quality Elevators by Garaventa ELVORON HR. Hydraulic Residential Elevator

INCLINATOR ELEVETTE HOME ELEVATOR. America s most customizable brand

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

SECTION DUMBWAITERS

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

Limited Use/Limited Application Elevator DESIGN GUIDE. ASME A17.1, Part V, Section 5.2. LU/LA Hydraulic Drive. symmetryelevator.com

A Quality Elevator by Garaventa

MACHINE ROOM INCLINATOR HOME ELEVATORS. Elevette : America s most customizable brand

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

Beautifully Crafted, Expertly Engineered, Thoughtfully Constructed

Residential Elevators

VERTICAL PLATFORM LIFT PLANNING GUIDE

SECTION INCLINE WHEELCHAIR LIFT PART 1 GENERAL 1.1 SECTION INCLUDES. A. Stair wheel chair lift. 1.2 RELATED SECTIONS

Vuelift Residential Elevator. Planning Guide

Vuelift RESIDENTIAL ELEVATOR PLANNING GUIDE

A LUXURY STANDARD CREATING A LIFETIME HOME

Planning Guide. Limited Use / Limited Application Elevator. Applicable Codes: ASME A17.1 Section 5.2 CAN/CSA B44

Planning Guide. Limited Use / Limited Application Elevator. Applicable Codes: ASME A17.1 Section 5.2 CAN/CSA B44. Part No m

Telecab RESIDENTIAL ELEVATOR. Planning Guide

Savaria Infinity Home Elevator. about Savaria. additional infinity options. t h E u lt i m at E q u i E t, S m o ot h r i d E. infinity cab FEaturES

An AIA Continuing Education Program

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR

You dream it. We build it. ELEVATORS

Your dream home deserves a dream elevator.

INTRODUCTION DEM RESIDENTIAL PLANNING GUIDE

VPL-3200B Residential Vertical Platform Lift Technical Specifications

Telecab RESIDENTIAL ELEVATOR. Planning Guide

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SPECIFICATIONS RENAISSANCE - Residential Elevator

Design Guide ASME A17.1, Part V, Section 5.3

Missouri Army National Guard (RTI) MOARNG Project No. T Rev. 0 Ft. Leonard Wood, Missouri 15 April 2013 Bid Final Submittal

PART 1- General LULA Elevator Section 14200

2. Cab, interior finishes, control panel and facings including cab doors. 3. Fire rated hoistway doors, sills, and frames.

VPL-3300B Commercial Vertical Platform Lift Technical Specifications

You dream it. We build it. ELEVATORS

Specification for MRL Passenger Elevators

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

SECTION HYDRAULIC PASSENGER ELEVATORS. A. Section ( ) - Cast-in-Place Concrete: Elevator pits.

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

FREEDOM 750 RESIDENTIAL ELEVATOR

SPECIFICATIONS. Part 1- General

Residential & Commercial Dumbwaiters

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

DIVISION 14 CONVEYING EQUIPMENT ELEVATORS

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

Series - 1

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

ORIONTM LIMITED USE / LIMITED APPLICATION ELEVATOR

VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) ILS-01100

Elevating your standard of living

Elevating your standard of living

Division 14 Conveying Systems

Series - 1

SECTION VEHICLE LIFTS. B. Section Basic Electrical Materials and Methods: Power and controls wiring.

Design Guide ASME A17.1, Part V, Section 5.2

Planning Guide (Imperial)

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

Outdoor Elevator ODE-500

2.2 Elevators may not include any proprietary controls or systems.

Project Manual Index of Specifications Shenandoah Schools Concession Building

REQUEST FOR INFORMATION

SECTION SECTIONAL OVERHEAD DOORS 592 SERIES THERMACORE INSULATED STEEL DOORS

Specification for Borehole Freight Elevators

Specification for Holeless Freight Elevators

Elevators and Lifts

SECTION SECTIONAL OVERHEAD DOORS THERMACORE AP MODEL 850 INSULATED STEEL DOORS

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 14 - CONVEYING EQUIPMENT DESIGN STANDARDS SECTION

PURCHASE CONTRACT FLA16-

SECTION VERTICAL PLATFORM LIFT

VILLAGE OF NEW LENOX COMMUNITY DEVELOPMENT DEPARTMENT 1 VETERANS PARKWAY NEW LENOX IL PHONE: (815) FAX:

LULA Commercial Elevator Specifications

July 17, 2009 Jarman Auditorium Renovation Project Code Little Project No

C. Section Metal Fabrications: Steel frame and supports.

Transcription:

SECTION 14 20 10 RESIDENTIAL ELEVATOR (Freedom Green Residential Elevator) PART 1 GENERAL 1.1 SECTION INCLUDES A. Residential Elevator. 1.2 RELATED SECTIONS A. Section 03 30 00 Cast-in-Place Concrete. B. Section 06 10 00 Rough Carpentry. C. Section 08 10 00 Doors and Frames. D. Section 09 21 16 Gypsum Board Assemblies. E. Section 09 60 00 Flooring. F. Division 16 Electrical. 1. Electrical service and disconnects. 2. Wire routing and connections. 3. Telephone service. 1.3 REFERENCES A. ASME A17.1 / CSA B44 Safety Code for Elevators and Escalators. B. NFPA 70 National Electric Code. C. CSA C22.1 Canadian Electric Code. D. Local state, province, city, township applicable codes. 1.4 REGULATORY REQUIREMENTS A. Obtain approvals from local jurisdiction authority. B. Complete work in compliance with national and local codes as listed in 1.3. 1.5 SUBMITTALS 14 20 10-1

A. Submit under provisions of 01 30 00. B. Product Information. 1. Site preparation instructions. 2. Freight receiving, handling, and storage instructions. 3. Installation methods. C. Shop Drawings. 1. Plan view with finished dimensions. 2. Elevation view with travel distances and anchor locations. 3. Isometric view showing orientation of openings. 4. Machine room details (if needed) 5. Electrical requirements. D. Finish Selection. 1. Make finish selections available digitally and physically. 2. Provide video with 3D virtual walk thru showing elevator with selected finishes. 1.6 DELIVERY, STORAGE, AND HANDLING A. Store products (unopened) until installation. B. Store products in covered, dry location. C. Protect products from theft and vandalism. 1.7 PROJECT CONDITIONS A. Elevator may not be used for hoisting materials and personnel during construction period. 1.8 WARRANTY A. Provide a 10-Year Warranty on mechanical components. B. Provide a 3-Year Warranty on electrical components. C. Provide a 1-Year Warranty on labor. 1.9 MAINTENANCE SERVICE A. Provide service and maintenance for one year after date of substantial completion. B. Provide maintenance contract for paid maintenance beyond 1 st year. C. Provide 24/7 phone support. 14 20 10-2

PART 2 PRODUCTS 2.1 MANUFACTURER A. Acceptable Manufacturer: Nationwide Lifts 1. Address: 10 Holden Avenue, Queensbury, NY 12804 2. Email: info@elevators.com 3. Toll Free: 888-323-8755 4. Website: www.elevators.com B. Substitutions not permitted. 2.2 FREEDOM GREEN RESIDENTIAL ELEVATOR A. Model Name. 1. Freedom Green. B. Drive System. 1. Cable Winding Drum or Chain Traction. 2. Variable Frequency Motor Drive. C. Safety Features. 1. Overspeed limiting device. 2. Safety brake system. 3. Emergency alarm and stop switch. 4. Final limit switches. 5. Gate switch. 6. Landing door interlocks. D. Electrical Requirements. 1. 230V, 30A service to a fused, lockable disconnect with auxiliary contact. 2. 115V, 15A service to a fused, lockable disconnect (for lighting circuit). 3. Functional phone line. E. Controls. 1. Fully automatic push button in cab and at landings. 2. Automatic car lighting. 14 20 10-3

F. Speed. 3. Position indicator in cab. 4. Microprocessor based controller. 1. 40 fpm (0.20 m/s). G. Number of Levels Serviced. H. Travel. 1. levels. 1. feet inches. I. Capacity. (choose one of the options below) 1. 950 lbs (431 kg). -OR- 2. 1000 lbs (454 kg). -OR- 3. 1400 lbs (635 kg). not allowed in all regions J. Car Size. (choose one of the options below) 1. 36 inches by 48 inches (914 mm by 1219 mm). -OR- 2. 36 inches by 54 inches (914 mm by 1372 mm). -OR- 3. 36 inches by 60 inches (914 mm by 1524 mm). -OR- 4. 40 inches by 48 inches (1016 mm by 1219 mm). -OR- 5. 40 inches by 54 inches (1016 mm by 1372 mm). -OR- 6. 44 inches by 48 inches (1118 mm by 1219 mm). -OR- 7. 40 inches by 60 inches (1016 mm by 1524 mm). requires 1400 lb capacity -OR- 8. 44 inches by 54 inches (1118 mm by 1372 mm). requires 1400 lb capacity -OR- 9. 48 inches by 48 inches (1219 mm by 1219 mm). requires 1400 lb capacity K. Platform Configuration. (choose one of the options below) 1. Enter/exit same side. -OR- 2. Enter/exit opposite sides (front and rear). -OR- 3. Enter/exit 90 degrees (front and side). L. Cab Fixtures Finish. (choose one of the options below) 1. Stainless Steel. -OR- 2. Oil Rubbed Bronze. -OR- 3. Brass. M. Cab Gate(s). (choose one of the options below) 1. Center-parting dual bi-fold gate. -OR- 2. Folding accordion gate. -OR- 3. Sliding 2-speed gate. N. Cab Gate Operation. (choose one of the options below) 1. Manual. -OR- 2. Automatic. 14 20 10-4

O. Cab Gate Finish. (choose one of the options below) 1. White Vinyl. -OR- 2. Clear Acrylic. -OR- 3. Aluminum. -OR- 4. Primed for paint. -OR- 5. Stainless Steel. -OR- 6. Unfinished Veneer Cherry. -OR- 7. Unfinished Veneer Maple. -OR- 8. Unfinished Veneer Oak. -OR- 9. Glass Panels. P. Landing Doors. (choose one of the options below) 1. Solid core wood doors at each landing, provided by GC. -OR- 2. Sliding 2-speed doors, provided by Nationwide Lifts. Q. Landing Door Operation. (choose one of the options below) 1. Manual. -OR- 2. Automatic. R. Landing Door Finish. (choose one of the options below) 1. By GC. -OR- 2. Primed for paint. -OR- 3. Stainless Steel. -OR- 4. Unfinished Veneer Cherry. -OR- 5. Unfinished Veneer Maple. -OR- 6. Unfinished Veneer Oak. -OR- 7. Glass Panels. S. Cab Wall Finish. (choose one of the options below) 1. Melamine Cherry. -OR- 2. Melamine Maple. -OR- 3. Melamine Oak. -OR- 4. Melamine White. -OR- 5. Unfinished Hardwood Veneer Cherry. -OR- 6. Unfinished Hardwood Veneer Maple. -OR- 7. Unfinished Hardwood Veneer Oak. -OR- 8. Finished Hardwood Veneer Cherry. -OR- 9. Finished Hardwood Veneer Maple. -OR- 10. Finished Hardwood Veneer Oak. -OR- 11. Finished Raised Hardwood Veneer Cherry. -OR- 12. Finished Raised Hardwood Veneer Maple. -OR- 13. Finished Raised Hardwood Veneer Oak. -OR- 14. Glass Panels. T. Cab Ceiling. (choose one of the options below) 1. White Melamine. -OR- 2. Match cab walls. U. Cab Lighting. (choose one of the options below) 14 20 10-5

1. LED recessed lights. PART 3 EXECUTION 3.1 EXAMINATION A. Site must be properly prepared prior to starting installation. B. Hoistway must be built to correct finished dimensions. C. Landing openings must have correct size and centerline location. D. Electrical power must be provided to disconnects as directed. E. Phone line must be provided. F. Controller space must have proper electrical clearances. G. If machine room is required, light and GFI outlet must be provided. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation. B. Prepare surfaces according to manufacturer s recommendations. 3.3 ELEVATOR INSTALLATION A. Install elevator in compliance with applicable codes noted in section 1.3. B. Install according to manufacturer s manuals and drawings. C. Startup and adjust equipment according to manufacturer s instructions. 3.4 FIELD QUALITY CONTROL A. Perform tests in compliance with applicable codes as noted in section 1.3. B. Perform tests/inspections as required by local jurisdiction. C. Demonstrate operation in front of Owner and Contractor. 3.5 CLEANING A. Remove protective films and coverings from equipment. B. Clean all components. 3.6 PROTECTION A. Protect installed products until completion of the project. B. Touch-up, repair, or replace any damaged components prior to completion. 14 20 10-6

END OF SECTION 14 20 10-7