Miscellaneous and Cast Iron Listings

Similar documents
Effective Date: Revision #: 1. Section I: Castings and Aluminum Covers. Valve Boxes. Service Clean-out Box and Lid

STANDARD CONSTRUCTION DETAILS SANITARY SEWER REVISED MARCH 2018 DEPARTMENT OF ENGINEERING

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

PERMANENT PAVEMENT REPAIR NO SCALE

APPLICABILITY TABLE. Council BSC CHRC GRC IRC LSC MRC RRC Applicable Yes Yes Yes Yes Yes Yes Yes

Light Duty Ramps. Loadingdocksupply.com PHONE:

AWI MANUFACTURING. Quality Products Since USDA Certified. Stainless Steel Floor Drains

4 ft. and 6 ft. Downstream Defender Handling and Installation Instructions

SDCS-02 CONSTRUCTION STANDARD FOR

ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.

General Legend Details...100

UNIVERSITY OF MISSOURI Electrical Manholes and Handholes 2016 Q1

The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 7

Qualified Product Policy 15 Drainage Structure Miscellaneous Components Qualified Product List 14 [G] Heavy Duty Gray Cast Iron

SECTION STORM DRAINAGE

Current Standard Plates including Transmittal Letters are available on the web at:

LINEAR DRAINAGE. Z886 Perma-Trench. 6" Perma-Trench Installation Instructions

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

16. Design of Pipeline Structures.

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

Miller Collective Safety at Height Solutions EPIC ULTRA Barrier System EPIC Post-N-Barrier System EPIC Basic Barrier System

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE

INTER-BUILDING CONDUIT & MANHOLE SYSTEM. Table of Contents PART 1 GENERAL 1 A. RELATED DOCUMENTS 1 B. SCOPE OF WORK 1 PART 2 PRODUCTS 6

Defence ] Defence 9/14 A DIVISION OF STRONGFORM GROUP

SUPPLEMENTAL DRAWINGS

WCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS

PRECAST RECTANGULAR CHAMBERS

STANDARDIZED STRUCTURES

SECTION A-A NTS. Figure 4.1 Alternative Flow Dispersal Trench NOTES:

Inlets & Catch Basins

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

Above are some of the trench drain components typical to an installation. Double check your order to ensure that you have all components particular to

Fabrication and Installation Table of Contents

Smarter. Safer. Leaner.

TYPE "A" CATCH BASIN

STANDARD DESIGN NOTES 1 / 2

Zurn Z886. 6" Perma-Trench. Installation Instructions

Wall Panels. Structural wall panel. Architectural wall panel. Cladding wall panel. Sandwich wall panel

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI

1. Add new Section 02655: Chilled Water (CHW) Distribution System (added 30 September 2009)

Installation and Maintenance Manual for EMH Freestanding Workstation Jib Cranes

Amendments to the January 2016 Design Criteria Manual & Supplementary Master Municipal Construction Documents

MAXIMUM TRENCH WIDTH AS REQUIRED SEE MEASUREMENT AND PAYMENT SECTION OF SPECIFICATIONS

BGZ-S Heavy-duty channel

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

Transformer Pads and BURD Cages

SCALE BAR 1:2500 RM OF WOODLANDS OVERALL PLAN - LOW PRESSURE SEWER MAIN. Certificate of Authorization JESSICA MANNESS ENGINEERING, INC. No.

SECTION WELDED STEEL WATER STORAGE TANKS

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

CONSTRUCTION SPECIFICATION FOR POLE ERECTION

Specialty Applications. for Keystone Walls

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF DESIGN

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

GB-20. Submittal Specifications Installation Application Specific Details

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION METAL ATHLETIC LOCKERS

INSTALLATION MANUAL. Hydrodynamic Separation. Bio Clean Environmental Services, Inc. 398 Via El Centro Oceanside, CA 92058

NOTE: 1) PRIOR TO BEGINNING WORK TRANSFER RIM ELEV. FROM MH K1 TO A TEMPORARY BENCH MARK FOR USE AS CONTROL DURING CONSTRUCTION. 2) CONTRACTOR TO INST

Linear Drainage ZF806 ZF812

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

Information Bulletin:

Zurn Z874. Trench Drain System. Installation Instructions

Zurn Z874. Trench Drain System. Installation Instructions

TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

TABLE OF CONTENTS

UNIFORM STANDARD DRAWINGS CLARK COUNTY AREA, NEVADA YEAR 2015 REVISIONS

Specification Drainage

Section SPHEROID ELEVATED WATER STORAGE TANK

MATERIAL SPECIFICATION FOR FRAMES, GRATES, COVERS, AND GRATINGS

PART 1- GENERAL. A. This section includes the following gymnasium equipment:

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

FLAT. The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

Concrete channels for professionals.

This drawing. is preliminary. and not for. construction or. implementation. purposes. project number 170 END VIEW DESIGN STRENGTHS: PLAN

FLOOR DRAINS AWI MANUFACTURING

ONTARIO PROVINCIAL STANDARD SPECIFICATION

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

Linear Drainage Z886. Perma-Trench. Installation Instructions. 100mm Clear Opening

Description Unit Quantity Rate Kshs. Amount Kshs.

SECTION PRECAST CONCRETE MANHOLES

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

SECTION MISCELLANEOUS METALS

FLOOR DRAINS AWI MANUFACTURING

Transcription:

aeconcrete.com May 2017 Miscellaneous and Cast Iron Listings Drawing Number Item Description Product Size (Length X Width X Depth in mm) SVVZ-20-SUMP-C Drainage Sump w/ Cover 660 x 510 x 765 i.d. SVVZ-NC-SUMP-C Drainage Sump w/ Cast Iron Frame & Grate 660 x 510 x 765 i.d. HD00-ZZ-FISH-C Fish Ladder 1400 x 900 x 1250 TRCH-20-1220-C Concrete Trench w/ B-10 Cast Iron Grate 1220 x 90 x 100 i.d. TRCH-20-0620-C Custom Slot Drain w/ B-14C Grate 7660 x 130 x 450 i.d. TRCH-92-B14C Slot Drain Grate (B-14C) 915 x 222 x 38 TRCH-20-1616-C Concrete Trench 5775 x 390 x 400 i.d. TRCH-20-0710-C Concrete Trench 5995 x 750 x1025 i.d. TRCH-NA-1010-C Concrete Trench 1010 (Flush Cover) Varies TRCH-NB-1010-C Concrete Trench 1010 (Super Imposed Cover) Varies LAWN-20-0255-C 255Ø Lawn Drain w/ 305Ø Cast Iron Grate 255Ø x 495 i.d. LOCK & LOAD-1-C LOCK & LOAD-2-C LOCK & LOAD-3-C 00CM-ZZ-2424-C Lock and Load Retaining Wall System (3 Pages) L & L Standard Panel & Counterfort L & L Corner Panel & Cap Stone L & L Half Wide Panel - Transition Pieces Cable Markers Large Cable Marker Small 610 sq x 100 310 sq x 75 FPAD-ZZ-2424-C Evergreen Pad 610 sq x 102 FPAD-ZZ-1616-C Heritage Lightweight Foundation Pad 406 sq x 100 0CCS-ZZ-0007-C 2130mm (7 Foot) Curb Stop 2130 x 200 x 152 SVTZ-41-ZZZZ-C Riser Ring 915Ø (100, 125, 150 High) Varies 00GR-41-ZZZZ-C Riser Grade Ring MH 610Ø (50, 100, 150 High) Varies Sales Office: 19060-54th Avenue, Surrey, B.C. Canada V3S 8E5 Shipping: 5353-192nd Street, Surrey, B.C. Canada V3S 8E5 Page 1

aeconcrete.com May 2017 Miscellaneous and Cast Iron Listings Drawing Number Item Description Product Size (Length X Width X Depth in mm) MHFC-97-0760-C C23 / C23A Cast Iron Manhole Frame & Cover MHFC-96-0610-C C18 Cast Iron Frame & Cover MHFR-93-MR6 MR-6 Valve Box Varies MHFR-93-MR8 MR-8 Valve Box MHFC-93-D14C D-14C Cleanout 454Ø x 104 RSLA-MB-3050-C VCLA-19AL-RUNG-C Aluminum Ladder w/ Safety Post (Ceiling or Wall Mount) Aluminum Ladder Rung Varies SUMP-RS-MISC-C Sumps, Risers & Covers 12" to 36" Diameter Varies Sales Office: 19060-54th Avenue, Surrey, B.C. Canada V3S 8E5 Shipping: 5353-192nd Street, Surrey, B.C. Canada V3S 8E5 Page 2

Painted Black, Steel Checker Plate Lids Options: Galvanizing, 25Ø Perforations 915 800 660 510 770 655 - Sump - Cover 805 660 695 550 765 865 300 x 300 K/O 100 End View Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Designed for Boulevard (Off-Road) Use - H-20 Static Loading Site Installation, Backfilling & Suitability for Use is the responsibility of others Drainage Sump w/ Cover Sump: 1,555 lbs / 710 kgs Cover: 125 lbs / 60 kgs Scale: 1:20 mm Rev: 28Jun08 SVVZ-20-SUMP-C

B-39/39A Cast Iron Frame and Grate 915 613 660 510 770 410 - Sump - Grate 765 865 300 x 300 K/O 100 End View Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Designed for Boulevard (Off-Road) Use - H-20 Static Loading Site Installation, Backfilling & Suitability for Use is the responsibility of others Drainage Sump w/ Cast Iron Frame and Grate Sump: 1,555 lbs / 710 kgs Grate & Frame: 210 lbs / 95 kgs Scale: 1:20 mm Rev: 28Jun08 SVVZ-NC-SUMP-C

1410 1100 600 910 700 1250 750 450 960 1350 300 300 1060 100 End View Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Site Installation, Backfilling & Suitability for Use is the responsibility of others Fish Ladder Sump: 2,950 lbs / 1,340 kgs Scale: 1:20 mm Rev: 21Jul14 HD00-ZZ-FISH-C

610 610 152 - Grate B-10 Cast Iron Grate (Typ 2) 1220 230 - Trench 170 115 90 End View Site Installation, Backfilling & Suitability for Use is the responsibility of others Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Concrete Trench w/ B-10 Cast Iron Grate Trench: 170 lbs / 77 kgs Grate: 32 lbs / 15 kgs Total: 202 lbs / 92 kgs Scale: 1:10 mm Rev: 28Jun08 TRCH-20-1220-C

7660 476 675 450 226 151 500 675 130 476 Section Scale: 1:10 Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Site Installation, Backfilling & Suitability for Use is the responsibility of others Custom Slot Drain Drain: 9,700 lbs / 4,400 kgs Scale: 1:50 mm Rev: 28Jun08 TRCH-20-0620-C

222 19 38 38 Cast Iron 915 38 End View Slot Drain Grate (B-14C) Grate: 77 lbs / 35 kgs Scale: 1:50 mm Rev: 28Jun08 TRCH-92-B14C-C

5775 600 500 410 Lid Options: Roof Slabs, Steel Covers, or Grating Recessed or Top Mounted to Suit Loading 500 400 50 100 390 Section Scale: 1:10 Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Site Installation, Backfilling & Suitability for Use is the responsibility of others Concrete Trench Trench: 4,450 lbs / 2,025 kgs Scale: 1:50 mm Rev: 28Jun08 TRCH-20-1616-C

5995 75 75 1150 Varies 750 Lid Options: Roof Slabs, Steel Covers, or Grating Recessed or Top Mounted to Suit Loading 600-1225 400-1025 200 1150 Section Scale: 1:30 Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Site Installation, Backfilling & Suitability for Use is the responsibility of others Concrete Trench Trench: 13,000 lbs - 21,350 lbs / 5,900 kgs - 9,700 kgs Scale: 1:50 mm Rev: 01May14 TRCH-20-0710-C

2390 2390 977-1892 - Trench - Cover Lid Options: -Roof Slabs, Steel Covers, or Grating -Recessed or Top Mounted to Suit Loading 100-150 580-1245 180 Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Site Installation, Backfilling & Suitability for Use is the responsibility of others * 300-965 Clear Inside 965 * Additional Widths Available (610, 760, 1220, 1525, or to Suit) End View Concrete Trench 1010 (Flush Cover) Trench: Subject to Height & Width Scale: N.T.S. Rev: 02Jun16 Cover: Subject to Height & Width TRCH-NA-1010-C

2390 2390 977-1892 - Trench - Cover Lid Options: -Roof Slabs, Steel Covers, or Grating -Super Imposed or Flush to Suit Loading 130-200 500-1165 300-965 Clear Inside 610-1525 * 180 * Additional Widths Available (610, 760, 1220, 1525, or to Suit) End View Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations). Typically Designed for 300 psf (14.4 kpa) or H-20 Traffic Loading. Site Installation, Backfilling & Suitability for Use is the responsibility of others Concrete Trench 1010 (Super Imposed Cover) Trench: Subject to Height & Width Scale: N.T.S. Page: 1/1 Cover: Subject to Height & Width TRCH-NB-1010-C

355Ø 305Ø 255Ø - Drain - Grate B2B Cast Iron Grate 110Ø Thru Hole 530 495 Product manufactured in accordance with CSA A23.4 Site Installation, Backfilling & Suitability for Use is the responsibility of others Lift Points Provided (See Shop Drawing for Quantity & Locations) Designed for Boulevard (Off-Road) Use - H-20 Static Loading 255Ø Lawn Drain w/ 305Ø Cast Iron Grate Drain: Grate: Total: 130 lbs / 60 kgs 8 lbs / 8 kgs 148 lbs / 68 kgs Scale: 1:10 mm Rev: 28Jun08 LAWN-20-0255-C

140 660 5/16" Stainless Steel Loop 30 95 812 406 25 Front View Terracing Panel & Counterfort Connection Stacking Process Products manufactured in accordance with CSA A23.4 Site Installation, Backfilling & Suitability for Use is the responsibility of others. Custom wall design available upon request Lock & Load Retaining Wall Wall: 160 lbs / 73 kgs Scale: 1:10 mm Rev: 28Jun08 LOCK & LOAD-1-C

(A) Corner Piece 5/16" Stainless Steel Loop 200 Note: Left Corner shown Right Corners available Inside Corners also available ~ 490 406 Front View (B) Cap Stone 710 325 Note: Std Cap Stone Shown 45º Corners also available 130 20 Front View 40 90 195 Products manufactured in accordance with CSA A23.4 Site Installation, Backfilling & Suitability for Use is the responsibility of others. Custom wall design available upon request Lock & Load Corner Piece & Cap Stone Corner: 140 lbs / 64 kgs Cap Stone: 135 lbs / 61 kgs Scale: 1:10 mm Rev: 28Jun08 LOCK & LOAD-2-C

95 406 35 406 20 25 40 Front View Products manufactured in accordance with CSA A23.4 Site Installation, Backfilling & Suitability for Use is the responsibility of others. Custom wall design available upon request Lock & Load - Half Wide Panels Panel: 55 lbs / 25 kgs Scale: 1:10 mm Rev: 28Jun08 LOCK & LOAD-3-C

610 Sq CABLE 305 Sq CABLE 100 75 Product manufactured in accordance with CSA A23.4 50 (2") High Letters on 305 x 305 Cable Marker 100 (4") High Letters on 610 x 610 Cable Marker Arrows Positioned as Required Lift Points Provided (See Shop Drawing for Quantity & Locations) Site Installation, Backfilling & Suitability for Use is the responsibility of others Cable Markers 305 Sq: 40 lbs / 20 kgs 610 Sq: 610 lbs / 100 kgs Scale: 1:10 mm Rev: 28Jun08 00CM-ZZ-2424-C

610 Sq 102 Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Site Installation, Backfilling & Suitability for Use is the responsibility of others Evergreen Pad Pad: 200 lbs / 91 kgs Scale: 1:10 mm Rev: 28Jun08 FPAD-ZZ-2424-C

406 Sq. 203 End View Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Site Installation, Backfilling & Suitability for Use is the responsibility of others Heritage Lwt Trailer Foundation Pad Pad: 75 lbs / 34 kgs Scale: 1:15 mm Rev: 28Jun08 FPAD-ZZ-1616-C

2130 Custom Length Available 200 Ø 25 Typ 152 (Optional) Custom Debris Drain Recess 152 200 End View. Scale: 1:5 Product manufactured in accordance with CSA A23.4 Lift Points Provided (See Shop Drawing for Quantity & Locations) Anchor Pins are Available as a Separate Item Site Installation & Suitability for Use is the responsibility of others 2130mm (7 Foot) Curb Stop Curb: 305 lbs / 140 kgs Scale: 1:15 mm Rev: 28Jun08 0CCS-ZZ-0007-C

940Ø min 60 35 Max Hook Clearance 1170 H Product manufactured in accordance with CSA A23.4 Site Installation, Backfilling & Suitability for Use is the responsibility of others Suitable for C23 / C23A Cast Iron Frame & Cover Hook Size: 10-8 (WLL= 3.15 T) Fits Recess Maximum Lift: 4 Risers w/ Lift Loops but lifting Voids Must align with 2nd Product otherwise Damage may Occur (min 1500 Rigging Length w/ 3 Lifter Bridle) Risers to be Set using Non-Shrink Grout by Others Riser Rings 915Ø H = 100 (4"): 200 lbs / 95 kgs, 12 / Pallet H = 127 (5"): 250 lbs / 115 kgs, 10 / Pallet H = 152 (6"): 300 lbs / 140 kgs, 8 / Pallet Scale: 1:15 mm Rev: 02Dec16 SVTZ-41-01ZZ-C

610Ø Ladder Rung Slots (150 & 100 Riser Only) 864 H Site Installation, Backfilling & Suitability for Use is the responsibility of others Product manufactured in accordance with CSA A23.4 Suitable for C18 Cast Iron Frame & Cover Riser Grade Rings MH 610Ø H= 50(2"): 80 lbs / 36 kgs H = 100(4"): 160 lbs / 73 kgs H = 150(6"): 250 lbs / 91 kgs Scale: 1:10 mm Rev: 28Jun08 00GR-41-ZZZZ-C

1020 Sq 762Ø 762Ø - Square Frame - Round Frame 835Ø 876 876 146 146 1130 Section Section Suitable for installation in roadways Site installation is the responsibility of others Custom marking of cover available (Electrical, Water, etc.) Available in Ductile Iron C23 Cast Iron Manhole Frame and Cover Frame: 340 lbs / 154 kgs Cover: 240 lbs / 109 kgs Scale: 1:20 mm Rev: 28Jun08 MHFC-97-0760-C

508Ø - Frame 565Ø 92 616 181 813 Section Suitable for installation in roadways Site installation is the responsibility of others Custom marking of cover available (Electrical, Water, etc.) Available in Ductile Iron C18 Cast Iron Frame and Cover Frame: 240 lbs / 109 kgs Cover: 140 lbs / 63 kgs Scale: 1:10 mm Rev: 28Jun08 MHFC-96-0610-C

SEWER DOBNEY Plan - Valve Box Plan - Lid Wgt: 15 lbs / 7 kgs 346 191 146 22 51 Section H H-20 Traffic Load Rated Lid Marking: "SEWER" or "WATER" or "OBSERV'N MONITOR WELL" 188 214 Elevation / Section MR-6 Valve Box H = 467 (18-3/8"): H = 314 (12-3/8"): 80 lbs / 36 kgs 55 lbs / 25 kgs Scale: NTS Rev: 28Jun08 MHFR-93-MR6-C

25 DOBNEY S E W E R Plan - Valve Box Plan - Lid 397 245 203 19 86 Section 467 H-20 Traffic Load Rated Option: Boltdown Lid Lid Marking: "SEWER" or "WATER" 233 251 Elevation / Section MR-8 Valve Box Box: 125 lbs / 57 kgs Scale: NTS Rev: 20Jan09 MHFR-93-MR8-C

SEWER DOBNEY DOBNEY 19 270 323 272 Bolt Locking Bar 104 254 454 Section D-14C Cleanout Cleanout: 75 lbs / 34 kgs Scale: 1:8 mm Rev: 28Jun08 MHFC-93-D14C-C

Ceiling Mount Brackets - Shipped Loose 369 155 Standard Offset 483 Top Two Rungs are Reinforced For Safety Post Wall Mount Brackets - Contractor Can Specify Custom Length - Bracket can be Welded to Ladder at Specified Location - Typically Shipped Loose - MH Mount Brackets Available upon Request Safety Post Extends and Locks 915mm Above Ladder 102 230 Standard Dimensions - Meets or Exceeds CSA Grade 1 Heavy Duty, ANSI Type 1A & OSHA (WLL: 300 lbs) - Standard Ladder Lengths are 3.0m, 3.66m, & 6.0m (10', 12', 20') 300 Typ Hardware Required to Install (Supplied & Installed by Others): - 1/2"Ø SS Bolts - 1/2"Ø SS Hilti Anchors Installation Instructions: - Ladders Typically Supplied Over Length to allow for Risers - Ladders over 3.66m Long are Supplied with an additional Center Support - Cut Ladder to Length Ensuring Clearance to the Access Hatch or MH Casting - Top Rung to be within 500mm of Finished Grade Elevation - Top Brackets to be Mounted within Top 2 Rungs (203 from Top of Ladder) - Manhole Mount Brackets Available Upon Request - Install Foot Brackets to Ladder by Drilling and Bolting through Ladder Frame (1/2"Ø SS Bolt) - Position Ladder & Mark Holes in the Ladder Frame for the Ceiling / Wall Brackets - Drill Holes in Ladder Frame - Install the Ceiling or Wall Mount Brackets to Ladder (1/2"Ø SS Bolts) 1 Each (Typ 4 to 6) - Place Ladder in Position & Hilti Bolt Brackets to Floor & Ceiling / Wall (1/2"Ø SS Hilti Anchors) - Confirm that All Bolts are Tight, Ladder is Secure, Safety Post Operates Smoothly & doesn't Interfere with Access Cover 76 457 Foot Brackets Shipped Loose Aluminum Ladder w/ Safety Post Scale: N.T.S. Rev: 20Feb17 RSLA-MB-3050-C

304 Plan 220 90 40 Front View Ø 19 Aluminum Ladder Rung Rung: 0.75 lbs / 0.4 kgs Scale: 1:4 mm Rev: 28Jun08 VCLA-19AL-RUNG-C

Sump w/ Base Armtec is a Distributor of the following products: Item # ID H A B C D INLET K/Os OUTLET K/O Weight (lbs) 12"Ø 305 457 229 229 178 178 1-130Ø 1-130Ø 170 18"Ø 457 610 406 381 356 330 1-130Ø 1-130Ø 340 24"Ø 610 914 584 508 533 457 1-200Ø & 2-130Ø 1-200Ø 861 30"Ø 762 914 584 508 533 457 1-200Ø & 2-130Ø 1-130Ø 1150 36"Ø 914 914 584 508 533 457 1-200Ø & 2-130Ø 1-130Ø 1400 Outlet 130Ø Donut Cover-Section Sump-Plan 3-3/4" Inlet & Outlet K/Os vary See Schedule below 130Ø 200Ø 130Ø Inlet 12"Ø (305mm) Risers & Covers Weight (lbs) 305Ø x 152 Riser 40 305Ø x 457 Riser (2 K/O) 145 Cover Solid Concrete 25 Cover Cast Iron D-14 Grate 35 18"Ø (457mm) Risers & Covers Weight (lbs) 457Ø x 152 Riser 65 457Ø x 305 Riser 130 457Ø x 610 Riser (2 K/O) 270 Cover Solid Concrete 30 Cover Perforated Concrete 30 Cover Cast Iron B-26C Grate 75 24"Ø (610mm) Risers & Covers Weight (lbs) 610Ø x 152 Riser 130 610Ø x 254 Riser 260 610Ø x 610 Riser 515 610Ø x 915 Riser 750 Cover Solid Concrete 120 Cover Cast Iron B-22B Grate 155 B D All Dimensions in mm unless noted otherwise Other Lid options & sizes may be available Ø C Sump-Section A H 30"Ø (762mm) Risers & Covers Weight (lbs) 762Ø x 152 Riser 150 762Ø x 152 Riser 300 762Ø x 254 Riser 700 762Ø x 915 Riser 960 Cover Solid Concrete 190 Cover Cast Iron B-22C Grate 95 Cover Donut Lid w/ 610Ø Opening (H-20) 300 36"Ø (915mm) Risers & Covers Weight (lbs) 915Ø x 152 Riser 195 915Ø x 254 Riser 385 915Ø x 254 Riser 770 915Ø x 915 Riser 1150 Cover Solid Concrete 250 Cover Donut Lid w/ 610Ø Opening (H-20) 350 Ladder Rungs Available in 915H Riser Sumps, Risers & Covers Scale: NTS Rev: 12Mar09 SUMP-RS-MISC-C