LABORATORY & DEIONIZED WATER SYSTEMS DESIGN AND CONSTRUCTION STANDARD

Similar documents
C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

A. Codes and Standards that are Standard at the University: 1. AGA Compliance: LC 1-91 Interior Fuel Gas Piping Systems

Systems. Barnstead MIX AND MATCH...WITH BARNSTEAD YOU HAVE A CHOICE

SECTION PACKAGE BOOSTER PUMP STATIONS

A. ASTM F Standard Specification for Pressure-rated Polypropylene (PP) Piping Systems.

SECTION PLUMBING PIPING SYSTEMS

Submittal for Aquatherm Piping System

University of Delaware

STATE UNIVERPROGRAM DIRECTIVES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.

2. Water Pressure Booster Systems. 3. Duplex Pedestal Type Sump Pumps.

Section 12 Hydraulics.

East Central College

Copyright 2004 and 2005 by The American Institute of Architects (AIA)

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

Design & Construction Standards, Revised January

SECTION SWIMMING POOLS STAINLESS, FULL TILE, OR TILE TRIM

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES

Series Sump and Sewage Systems

HYDRONIC PIPING CHAPTER 12

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

SECTION CHEMICAL FEED SYSTEM

University of Delaware

A. Piping materials shall bear label, stamp, or other markings of specified testing agency.

Preparation of Reagent Water

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

C. Up to Two and One-half (2-1/2) inches: Full port, 2-piece, bronze body ball valves with teflon seat conforming to MSS SP-110.

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

SECTION PLUMBING PIPING SYSTEM

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

HYDRONIC PIPING CHAPTER 12

University of Delaware

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building.

SECTION COOLING TOWER

SANITARY WASTE AND VENT PIPING

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

REVERSE OSMOSIS WATER TREATMENT

SAFE-TANK DOUBLE WALL TANKS HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)

SECTION FACILITY STORM DRAINAGE PIPING

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

SECTION POLYVINYL CHLORIDE (PVC) WATERLINE

Bid Opportunity PLUMBING SYSTEMS Section Installation of Boiler Heating Systems Page 1 of 7 Centennial Pool, 90 Sinclair

Advanced Water Supply and Distribution

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

SECTION FACILITY POTABLE WATER DISTIBUTION

Design and Construction Standards SECTION POTABLE WATER SYSTEMS

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S

Sea Water Reverse Osmosis Container. 1. Description:

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

A. This Section includes exterior piping for vertical, direct-buried, ground-loop, heat-pump systems that operate between 23 and 104 deg F.

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

B. System Design and Performance Requirements

A. Product Data: For Piping, fittings, transition fittings and dielectric fittings.

SUGGESTED SPECIFICATIONS Pump Frames through 64132

Fencing, locks on access manholes, and other necessary precautions shall be provided to prevent trespassing, vandalism, and sabotage.

Michigan State University Construction Standards. DOMESTIC WATER PIPING Page SECTION DOMESTIC WATER PIPING PART 1 - GENERAL

HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

2. A preconstruction meeting with the TWA s staff is required prior to initiating construction.

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

SECTION HVAC WATER TREATMENT

1. Add new Section 02655: Chilled Water (CHW) Distribution System (added 30 September 2009)

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

SECTION (15150) - SANITARY WASTE AND VENT PIPING

TARRANT COUNTY PURCHASING DEPARTMENT

UNIVERSITY OF MISSOURI Hydronic Energy Distribution 2016 Q1

1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s].

1. Required Minimum Flow:

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

BuildingName The Description of the Project P DOCUMENTS

SECTION HYDRONIC PIPING

SEWER SYSTEM DESIGN GUIDELINES

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

MRI Chiller Installation Guidelines

D-10 OUTLINE SPECIFICATION FOR PRE FAB Undergrd Piping System

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal

SUGGESTED SPECIFICATIONS

MRI Chiller Installation Guidelines

PERC-RITE DRIP DISPERSAL DESIGN SUBMITTAL American Manufacturing Company, Inc

SECTION FACILITY STORM DRAINAGE PIPING

SECTION WET-PIPE SPRINKLER SYSTEMS

DUKE UNIVERSITY CONSTRUCTION & DESIGN STANDARDS

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.

San Antonio Water System Standard Specifications for Construction ITEM NO. 848 SANITARY SEWERS

System & Equipment Checkout Procedure Client Name Plant Location

BASIC MATERIALS & METHODS

PROJ. NO SECTION DOMESTIC WATER SOFTENERS

A. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.

Youngstown State University

SECTION HVAC INSTRUMENTATION AND CONTROLS INSTALLATION. (Applicable to IUPUI Only)

VSS S U B M E R S I B L E S E W A G E P U M P S

Index - Section 40M Medium Sump / Drainage Pumps Bulletins 4508

TYPICAL INSTALLATION INSTRUCTIONS

CMS, FDA and AAMI Requirements for Bicarbonate Systems Made Simple. Compiled January 2012 by AmeriWater Incorporated

t y p e V S A S E W A G E P U M P

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System

Transcription:

PART 1: GENERAL 1.01 Purpose A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the principles of this section such that the University may achieve a level of quality and consistency in the design and construction of their facilities. Deviations from these guidelines must be justified through LCC analysis and submitted to the University for approval. 1.02 Codes and Standards A. Plumbing Code Compliance: Comply with applicable portions of International Plumbing Code pertaining to selection and installation of plumbing materials and products. Design shall conform to the Uniform Plumbing Code requirements where interaction occurs with City of Austin utilities or infrastructure. 1.03 Requirements A. The UT-Austin campus has a central system for distribution of de-ionized water which is referred to as lab water. (For historical reasons, it is often referred to as distilled water.) The Lab water is carried in pressurized PVC Schedule 80 lines in the utility tunnels and up to the building storage tanks. B. The central reverse osmosis/demineralizer system is designed to produce water that meets the following quality specifications: Parameter Quality Specification* Conductivity < 15 microsiemens ph 6.0 to 9.0 Nonvolatile TOC < 1.0 ppm * Under normal operating conditions, conductivity is less than 0.5 micromhos/cm, and TOC is non-detectable (Practical Quantitative Limit of.5 ppm). C. If project requirements demand water quality in excess of that listed above, provide supplemental point-of-use polishing systems necessary to provide a continuous supply of water that meets individual water purity requirements. D. For buildings requiring DW, provide a 1 PVC 80 line from the tunnel DW main up to a nonpressurized DW tank in the attic. This supply line should have a stainless steel ball valve for isolation purposes with a tee and stainless steel drain ball valve located at the tunnel entrance. Provide a stainless-steel orifice in the line (1/4 for buildings with large DW demand, 1/8 for buildings with small demand) to limit the amount of makeup to the tank. Provide a valved bypass line around the orifice to allow expedited system refill after being drained. E. Provide a stainless-steel solenoid valve to maintain the level in the DW tank. Provide a valved bypass line with stainless steel ball valves to bypass the solenoid and orifice. Provide a larger PVC line (often 2 inch) to allow DW flow by gravity or booster pump system from the tank to Design & Construction Standards, Revised January 2014 22.67.13.19-1

the building uses. Booster pump systems shall be required to provide adequate pressure to upper floors and building areas with high volume demand equipment. F. An ultraviolet sterilizer shall be installed in the piping downstream of the DW storage tank. G. DW Storage tank shall be provided with tank level sight glass. Sight glass shall be piped external to tank and be provided with isolation service valves at top and bottom of glass. Sight glass shall be equipped with high and low level switches as well as high-high and low-low level alarm switches. Switches shall be located within the section of sight glass isolated by service valves. Switches shall provide dry contacts for reporting conditions to BAS/FCMS system. H. Provide means of flushing DW system from each end of main system feed on each floor of building with access. New or modified systems shall be designed to incorporate the means to maintain the integrity of water quality to prevent any system contamination. Care shall also be taken to prevent contamination to materials stored or in transit. Any modifications to the system piping or equipment shall require prior notification and pre approval from UT Facilities Services. Design shall provide for future remodeling and incorporate the flexibility to accommodate future changes in research having minimal effect on adjacent labs and research programs and the means to maintain the integrity of water quality during any system modifications to prevent system contamination. I. Provide each riser connection serving a building floor or area with section valves for isolation with access. Provide each branch connection to main feed serving a floor or area with section valves for isolation with access. Branch connections from main feeds shall be from top of header. J. Provide de-ionized water piping loop to minimize dead legs. Dead legs over 12 shall not be allowed. K. Provide circulation in all de-ionized water loops at three feet per second minimum, with a target pipe velocity of five feet per second. PART 2: PRODUCTS 2.01 Standards for Basic Identification: A. General: Piping identification Standard at the University is ANSI A13.1 "Scheme for Identification of Piping Systems. All piping shall have flow arrows indicating direction of flow. 2.02 Lab Water Piping, Valves and Fittings: A. Pipe valves and fittings for purified water service shall be Schedule 80, Flame Retardant natural virgin, unpigmented Polypropylene or PVDF with socket thermo seal fusion fittings. The piping upstream of the tank should be schedule 80 PVC with stainless steel ball valves. B. Installation practices, including support spacing and joint fusion, shall be in compliance with manufacturer's printed recommendations. Design & Construction Standards, Revised January 2014 22.67.13.19-2

C. Materials from which pipe, fittings and valves are manufactured shall have been tested and approved for conveying potable water by the National Sanitation Foundation (NSF). All pipe, fittings and valves shall bear the NSF hallmark indicating that the material has been tested and approved for conveying lab water by the (NSF). D. To ensure installation uniformity, all system piping components shall be the products of one manufacturer. E. All piping shall be thoroughly rinsed and flushed to remove all dirt and debris before installation. After installation the Contractor shall flush the entire piping system with deionized water to the satisfaction of the Owner. F. All piping exposed within plenums shall have a smoke-developed index of no more than 50 and flame-spread index of no more than 25. All non-conforming piping material located in plenums shall be sleeved. Contractor shall provide a sleeved system through the installation of grooved Schedule 10 galvanized piping and couplings. The sleeve piping shall be no less than 2 inches greater diameter than the polypropylene piping contained within it. Only rolled groove piping may be used. The Victaulic "Fit" fittings and piping system, or any similar set screw type fitting system is specifically prohibited. Vic-Let and Vic-O-Well or similar type fittings are specifically prohibited for use in this application. Where a reduced tee fitting is required, then a reducing tee or regular tee with bell reducer shall be used. If any of the above described prohibited materials or installation methods are used, then the material or installation method shall be corrected at the contractor s expense. G. Valves shall be ball valve type and shall be manufactured of the same virgin, unpigmented molding compound as the fittings to assure compatibility. H. All ball valves shall have Viton seals, and PTFE seats. Ball valves shall carry a pressure rating of 150 psi at a minimum of 68F, and shall be of True Union design. 2.03 Lab Water Pumps: A. Pumps shall be heavy duty plastic or stainless steel duplex, centrifugal type. B. Pump heads, sleeve and impeller shall be polypropylene or stainless steel. Seal shall be mechanical type. C. Each pump shall be provided with a fused safety switch and a magnetic starter providing overload and under voltage protection. A mechanical alternator shall automatically alternate the operation of the pumps D. Pumps shall be furnished completed with Vinton, or approved equal, suction and discharge pressure gauge isolator-activators to separate gauge from deionized water. 2.04 Level Controller: A. Level controller shall be full plastic body type with no metal parts in contact with deionized water. Ultrasonic controllers are also approved. 2.05 Holding Tanks: Design & Construction Standards, Revised January 2014 22.67.13.19-3

A. Furnish and install heavy duty plastic polypropylene or polyethylene tanks that are food grade or NSF rated. B. Tanks shall be suitable for 75 psig pressure and 120 degree F. temperature. C. Tanks shall be vertical cylindrical type, with dished or conical bottom. Tank overflow can be piped to the steam condensate system when possible or the recovered water system. Tank shall have a tight-fitting removable cover, a steel floor stand, an air filter capable of removing particles as small as 0.5 micron. 2.06 Flow Control Valves: A. Provide a 3/8 inch PP flow control valve in each and every lab water outlet that limits the flow to 1/2 GPM. Provide a 2 GPM a natural, virgin, unpigmented polypropylene flow control valve in each de-ionized water connection to equipment. B. Flow control valves shall maintain a constant flow regardless of inlet pressure changes between 15 and 100 psig. No metal shall be in contact with the liquid. 2.07 Pressure Regulating Valves: A. Contractor shall supply and install, where shown on the drawings, socket fusion natural, virgin, unpigmented polypropylene pressure regulating valves. B. Valves shall accurately reduce and regulate steady or varying inlet pressures and maintain a constant predetermined outlet pressure. 2.08 Pressure Gauges: A. Pressure GAUGES shall be 2-1/2 inch diameter, dual calibrated for 0 to 100 psig and SI units, having 316 stainless steel bourdon tube. Provide gauges with inline dead-leg gauge guards where possible. 2.09 Purified Water Storage Tank: A. Tank shall be vertical cylindrical type, stainless steel or FRP-jacketed polyethylene, with dished or conical bottom. Tank shall have a tight-fitting removable cover, a steel floor stand, an air filter capable of removing particles as small as 0.5 micron, and rounded interior corners. All tank penetrations shall be factory made. Stainless steel tanks shall be No. 4 finish; polyethylene tanks shall be made of FDA approved resin. Stainless steel tanks shall be No. 4 finish; polyethylene tanks shall be made of FDA approved resin. 2.10 Level Sensors: A. Level sensors shall have only stainless steel and Viton in contact with the fluid. Each shall have a snap action switch rated for 125 volts, with an adjustable deadband initially set at 3 inches. B. One level sensor shall be wired with the solenoid valve to automatically maintain the liquid level in the tank. The other is to be connected to the BAS system. Design & Construction Standards, Revised January 2014 22.67.13.19-4

PART 3 EXECUTION 3.01 Installation: A. At every floor penetration a cast in sleeve or other monolithic curbing at least 2 inches high shall be provided to help contain water spills or leaks. B. Locate groups of pipes parallel to each other, spaced to permit applying full insulation and servicing of valves. END OF STANDARD Design & Construction Standards, Revised January 2014 22.67.13.19-5

5.22.60 LABORATORY & DEIONIZED WATER SYSTEMS Design & Construction Standards, Revised September 2012 5.22.60-6