CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance

Similar documents
BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

Design No. M507. Design No. M507

Design No. L565. Design No. L565

Page 2 of 5 1. Flooring Systems The flooring system shall consist of one of the following: System No. 1 Subflooring Nom 23/32 in. thick wood structura

Duct Wrap Flexible Wraps

Design No. U415 BXUV.U415 Fire-resistance Ratings - ANSI/UL 263. Design No. U415

Design No. L551. Design No. L551

BXUV.U435. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

Joint Systems. System No. FF-D-0044

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

BXUV.L576 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

BXUV.U415 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

AUTHORIZATION TO MARK

UL Design System HW-D-1012 continued

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 11

BXUV.L548 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

XHBN.HW-D Joint Systems. Design/System/Construction/Assembly Usage Disclaimer. Joint Systems. System No. HW-D-0631

research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP REVISION 2007

Building Division Informational Handout

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

PinkWood Ltd. Revised September 29, 2017

LISTING INFORMATION OF International Fireproof Technology Inc. - Joint Systems SPEC ID: 43848

BXUV.U411. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Stark Truss Company, Inc. Revised December 14, 2018

WALL ASSEMBLIES. PHILLIPS MANUFACTURING CO. - Omaha, NE USA DESIGN NO. PMC/WA DESIGN NO. PMC/WA 60-01

BXUV.L521 - Fire Resistance Ratings - ANSI/UL 263. Fire Resistance Ratings - ANSI/UL 263

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

CHEF YANG 118 HOMETOWN PLAZA SELLERSBURG, IN CHEF YANG SELLERSBURG, IN HOMETOWN PLAZA WOMEN MEN LAVATORY SIDE SITE. 56"min.

Colorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International

Boise Cascade Company Revised June 25, 2018

System No. SP777 (FOR HORIZONTAL OR VERTICAL SEPARATIONS)

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

FIRESTOP SUBMITTAL PACKAGE

Building Guide. olorado Chapter of the International Conference of Building Officials. Lancaster County Building Department

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

JB ENGINEERING AND CODE CONSULTING, P.C Cardinal Drive Munster, IN Phone: Fax:

SECTION THERMAL INSULATION

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

Fire Protection Products. Firestop Submittal Package FIP 1-Step Firestop Foam. Electrical Trade

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

SECTION NON-STRUCTURAL METAL FRAMING

WALL CONSTRUCTION CHAPTER 6

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

System No. C-AJ-8133

GAF EnergyGuard Polyiso Wall Sheathing

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

R-Matte Plus-3: Insulation for the Building Envelope

FIRESTOP SUBMITTAL PACKAGE

WALL CONSTRUCTION CHAPTER 6

CAJ. Combos. C-AJ of 5. Through Penetrations Series. Concrete. 3Fire Protection Products

SECTION Fiber Reinforced Stucco 1

GA APPLICATION OF GYPSUM SHEATHING

System No. HW-D-0548

GYPSUM BOARD AND PLASTER

WALL CONSTRUCTION CHAPTER 6

REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: September 14, 2012 REVISED DATE: N/A

Acknowledgments. Abstract

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].

System No. HW-D-0119

ICC-ES Evaluation Report Reissued May 1, 2010 This report is subject to re-examination in two years.

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

FIRE DESIGN & INSTALLATION GUIDE

The System U.S. Patent No. 5,913,788

Gold Bond BRAND Gypsum Sheathing

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

Appendix D. -Weyerhaeuser Fire Rated Assembly Listings-

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

Acknowledgments. Abstract

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

EVALUATION SUBJECT: AQUAPEX PRESSURE RATED TUBING, PROPEX AND COMPRESSION TYPE FITTINGS

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION NON--STRUCTURAL METAL FRAMING

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

Gold Bond BRAND Kal-Kore Plaster Base

SECTION GYPSUM BOARD

SECTION HANGERS AND SUPPORTS FOR PLUMBING

ATI Evaluation Service A Division of Architectural Testing Certification Services

HIGH PERFORMANCE FIRE RETARDANT TREATED WOOD PRODUCTS

System No. C-AJ-8048

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Response to Bidder Questions

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

WALL CONSTRUCTION CHAPTER 6

Design No. L524 BXUV.L524

Transcription:

INFO 33, page 1 CEYDC.R25563 Nonmetallic Plumbing System Components Listed for Fire Resistance HEATLINK GROUP INC R25563 4603E 13TH ST NE CALGARY, AB T2E 6M3 CANADA Types Purelink PEXa, Heatlink PEXa and Purelink Plus nonmetallic tubing for use in Design Nos. J900, M516, W316 and W458. As an option, Purelink PEXa, Heatlink PEXa and Purelink Plus nonmetallic tubing covered with Classified Floor Topping Mixtures or other concrete toppings may be installed over the required floor system components in L500 and M500 series designs. L500 or M500 series fire-rated assembly Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of ULC Listed products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by ULC for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear ULC's Mark are considered Listed.

INFO 33, page 2 Design No. J900 BXUVC.J900 Restrained Assembly Rating 2 h Unrestrained Assembly Rating 1-1/2 and 2 h (See Item 1) 1 2 3 1. Normal Weight Reinforced Concrete Reinforced slab and beam designed in accordance with the current edition of CSA A23.3, Design of Concrete Structures. Carbonate aggregate, minimum compressive strength of 25 MPa. Minimum slab thickness and reinforcement cover specified in the table below: Restrained Assembly Rating, h Unrestrained Assembly Rating, h Min Total Slab Thickness, mm 2 2 150 38 Min Concrete Cover for Positive Reinforcement, mm 2. Steel Reinforcement Various sized Grade 280 and Grade 420 deformed steel bars located as required by CSA A23.3 for positive and negative reinforcement. Minimum concrete cover for positive reinforcement as described in Item 1. 3. Non-Metallic Plumbing Components (CEYDC) Nominal 12.7 mm through 50.8 mm O.D. tubing, evenly distributed and tied to the top side of the positive reinforcing bars. The tubing may be placed inside a flexible or rigid polyethelene or rigid PVC sleeve. The tubing may penetrate the floor slab through a sill plate and into a stud cavity of a wall as necessary. Tube bends may be supported by suitably sized PVC elbows. The maximum amount of tubing shall be as specified in the table below: Restrained Assembly Rating, h Unrestrained Assembly Rating, h 2 2 0.925 Max. volume of tube per cubic metre of concrete, % HEATLINK GROUP INC Types Purelink PEXa, Heatlink PEXa, PureLink Plus

INFO 33, page 3 Design No. M516 BXUVC.M516 Unrestrained Assembly Rating - 1 h Combustible Construction (Finish Rating - 27 minutes) 1. Flooring System The flooring system shall consist of one of the following: (a) Subflooring Minimum 12 mm thick wood structural panels, min grade "C-D" or "Sheathing". Face grain of plywood or strength axis of panels to be perpendicular to the joists with joints staggered. (b) Vapor Barrier Nominal 0.25 mm thick commercial rosin-sized building paper. (c) Finish Flooring Minimum 15 mm thick plywood, minimum grade "Underlayment" or "Single Floor". Face grain of plywood to be perpendicular to the joists with joints staggered. 2. Wood Joists Minimum 38 mm by 235 mm, spaced 406 mm OC and effectively firestopped in accordance with the Building Code. 3. Cross Bridging Minimum 19 mm by 64 mm or minimum 38 mm by 235 mm solid blocking. 4. Gypsum Board (CKNXC). 15.9 mm thick, 1220 mm wide gypsum board installed with long dimension perpendicular to joists with end joints located under bottom of joists. End joints in adjacent rows shall be staggered on adjacent joists. Gypsum board secured with 8d cement coated common nails spaced 150 mm OC along the edges and in the field. Nails located 13 mm from butted end joints. CGC INC Types C, AR, WRC.

INFO 33, page 4 5. Non-Metallic Plumbing Components (CEYDC). Nominal 6mm, 10 mm, 13mm, 16mm, 19mm, 25 mm, 32 mm, 38 mm and 50 diameter tubing attached to joists with plastic, steel or copper hangers (Item 6), spaced maximum 1015 mm OC. The minimum spacing between the bottom of tubing and the top or backside of the gypsum board shall be 75 mm. The tubing shall penetrate the floor through a sill plate and into a stud cavity of a wall. The maximum amount of tubing shall be 0.31 kg of tube per meter length of joist cavity. HEATLINK GROUP INC Types Purelink PEXa, Heatlink PEXa, Purelink Plus 6. Fasteners Nominal 12 mm to 25 mm wide perforated steel or copper straps, or steel or copper U or C shaped brackets with a radius conforming to the outer circumference of the tube to be supported. Plastic fastener supplied by tubing manufacturer may also be used. Fasteners to be nailed to the wood joists using minimum 25 mm long nails. 7. Fill Void or Cavity Material - Sealant (XHJZC). Minimum 10 mm thickness of fill material applied within the annulus, flush with top surface of the sill plate. Prior to the application of the sealant, 10 mm thickness of 64 kg/m3 mineral wool insulation shall be installed in the annular space and recessed by 10 mm from the top surface of the sill plate. Maximum annular space between tube and edge of opening shall be 6 mm. Tubing (Item 5) intended as a process or supply plumbing component. 3M COMPANY 3M FIRE PROTECTION PRODUCTS Type CP 25W+. 8. Finishing System (Not shown) Joint compound, applied in two coats to joints and nail-heads. Nominal 50 mm wide paper tape embedded in first layer of compound over all joints.

INFO 33, page 5 Design No. W458 BXUVC.W458 Assembly Rating 1 h 7 1. Floor and Ceiling Runners (not shown) - Channel shaped runners, minimum 92 mm. wide with 32 mm legs, formed from minimum 0.838 mm thick (20 MSG) galvanized steel, attached to floor and ceiling with fasteners spaced maximum 600 mm OC. 4 8 4 2 2. Steel Studs Channel shaped, minimum 92 mm wide, 32 mm legs, 5 mm folded back returns, formed from minimum 0.838 mm thick (20 MSG) galvanized steel spaced maximum 600 mm OC. 6 3. Batts and Blankets (Optional, Not shown) - ULC listed mineral wool or glass fibre batts partially or completely filling stud cavity. 4. Gypsum Board (CKNXC). 15.9 mm thick, 1220 mm wide, attached to steel studs and floor and ceiling track with 25 mm long, Type S steel screws spaced 204 mm OC. along edges of board and 305 mm OC in the field of the board. Joints oriented vertically and staggered on opposite sides of the assembly. CGC INC Types C, AR, WRC, SECUROCK FIRECODE X, Type USGX. 5. Joint Tape and Compound (Not Shown)- Joint compound applied in two coats to joints and screw heads; paper tape, 50 mm wide, embedded in first layer of compound over all joints. 6. Non-Metallic Plumbing System Components (CEYDC) Nominal 6mm, 10 mm, 13 mm, 16 mm, 19 mm, 25 mm, 32 mm, 38 mm and 50 mm diameter tubing attached to cross bracing (item 7) with plastic, steel or copper fasteners (Item 8). The tubing may be connected to standard copper or brass-plumbing components, tees, bend supports and manifolds within the cavity. Plastic manifolds, with a weight not exceeding 2.13 kg per cavity may be used in lieu of or in addition to copper or brass manifolds. The maximum amount of tubing per stud cavity shall be 0.7 kg/m and shall not exceed a total weight of 2.13 kg per stud cavity. HEATLINK GROUP INC Types Purelink PEXa, Heatlink PEXa, Purelink Plus Nonbearing Wall 7. Bracing Minimum 0.838 mm thick (20 MSG) galvanized steel, minimum 92 mm wide, 32 mm legs, 5 mm folded back returns, or 38 mm by 89 mm lumber cut to fit within the stud cavity. The maximum spacing between bracing in cavities that contain tubing shall be 1015 mm OC. The bracing shall be screw attached to the studs using two standard 25 mm long Type S screws at each end of bracing member. 8. Fasteners Standard copper, brass, steel or plastic plumbing fasteners. The fasteners shall be screw attached to the bracing using a minimum 22 mm long screw.

INFO 33, page 6 Design No. W316 BXUVC.W316 Assembly Rating - 1 Hr 6 1. Wood Studs Nominal 38 mm by 89 mm spaced 406 mm on center, effectively cross braced at midheight and fire stopped at top and bottom. 3 2. Batts and Blankets (Optional, Not shown) - ULC listed mineral wool or glass fibre batts partially or completely filling stud cavity. 3 7 5 1 3. Gypsum Board (CKNXC). 15.9 mm thick wallboard applied vertically. Wallboard nailed 175 mm OC with 6d cement coated nails 48 mm long, 2.5 mm shank diameter and 6 mm diameter heads. CGC INC Type C, AR, WRC, SECUROCK FIRECODE X, Type USGX Bearing Wall - (Finish Rating 23 Min) 4. Joint Tape and Compound (Not Shown). Joint compound, applied in two coats to joints and nails heads; paper tape, 50 mm wide, embedded in first layer of compound over all joints. 5. Non-Metallic Plumbing System Components (CEYDC). Nominal 6mm, 10 mm, 13 mm, 16 mm, 19 mm, 25 mm, 32 mm, 38 mm and 50 mm diameter tubing attached to cross bracing (Item 6) with plastic, steel or copper fasteners (Item 7). The tubing may be connected to standard copper or brass-plumbing components, tees, bend supports and manifolds within the cavity. Plastic manifolds, with a weight not exceeding 2.13 kg per cavity may be used in lieu of or in addition to copper or brass manifolds. The maximum amount of tubing per stud cavity shall be 0.83 kg/m and shall not exceed a total weight of 2.54 kg per stud cavity. HEATLINK GROUP INC Types Purelink PEXa, Heatlink PEXa, Purelink Plus 6. Bracing Nominal 38 mm by 89 mm lumber cut to fit within the stud cavity. The maximum spacing between bracing in cavities that contain tubing shall be 1015 mm OC. The bracing shall be screw attached to the studs using standard 25 mm long Type S screws or nailed with nails suitable for wood framing construction. 7. Fasteners Standard copper, brass, steel or plastic plumbing fasteners. The fasteners shall be screw attached to the bracing using a minimum 22 mm long screw.