Submittal Packages Detailed with Items and Reviewers

Similar documents
Residential and Commercial Insulation Products

CertaPro Thermal FSK-25 Faced Batts

Commercial Insulation

Thermal/Acoustical Insulation. Knauf Data Sheet BI-BT-DS 08-13

Knauf Data Sheet BI-DS Thermal/Acoustical Insulation

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 2-17

EcoTouch Insulation with PureFiber Technology

Thermal/Acoustical Insulation. Data Sheet BI-RL-DS 05-18

THERMAL INSULATION

Section Roof/Ceiling Thermal Insulation

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17

RESIDENTIAL INSULATION

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Originally Issued: 05/03/2013 Revised: 06/06/2016 Valid Through: 05/31/2017

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 11-15

Foil Back Gypsum Board

Distinguish your homes with spray foam insulation from a name you can trust.

Thermal/Acoustical Insulation. Data Sheet BI-BT-DS 08-17

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards PAGE

RAY-CORE Structural Insulated Roof and Wall Panels

Residential Product Selector Guide

Residential Insulation

Deer Ridge Consulting, Inc.

Building Insulation Submittal Form

SECTION Blown Insulation THERMAL INSULATION

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

SECTION A. American Society for Testing and Materials (ASTM):

12 MOST COMMONLY ASKED QUESTIONS ABOUT HOME INSULATION

THERMAL AND MOISTURE PROTECTION

SECTION PRE-ENGINEERED BUILDING INSULATION

HPW Protocol Reference Manual

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

(Rev. 2000) STANDARD

SECTION (07200) - THERMAL PROTECTION

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SECTION INSULATED CONCRETE FORMS - RASTRA 1.01 SUMMARY

A. ASTM C203: Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation

SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here)

RLGA. Gypsum Board Construction 2012 International Building Code. By Ronald L. Geren, AIA, CSI, CCS, CCCA, SCIP

EcoTouch INSULATION SPECIFICATIONS

SECTION INSULATION. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

A. Source Limitations: Obtain each type of building insulation through one source.

1. Building insulation in batt form. 2. Rigid board insulation. 3. Cavity wall insulation.

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

DiSorb Diffuser Product Specifications Section Sound Diffuser-Absorber for Ceilings and Walls (DiSorb Diffuser-Absorber)

Residential. Building Insulation Guide

Ceiling Tiles C200B - Specification

Insulation Systems Submittal Form

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

(Rev. 2000) STANDARD

EcoTouch INSULATION SPECIFICATIONS

Building Insulation Submittal Form

BENJAMIN OBDYKE INCORPORATED

Guide Specification for the OSI QUAD Window and Door Flashing System

The Optimal Solution for MidFloor Applications

SECTION STRUCTURAL INSULATED PANELS

In addition to performing as an interior vapor retarder, MemBrain the Smart Vapor Retarder may be installed as a continuous, interior

SECTION SPRAY FOAM INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Guide Specification SECTION DUCT INSULATION

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Geometrik Manufacturing Inc.

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

SECTION Fiber Reinforced Stucco 1

CertainTeed DRYRIGHT. Moisture Control Fiber Glass Insulation

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Architectural precast Concrete EARTH FRIENDLY BLOCK

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

Insulation Board. Knauf Data Sheet PE-DS

ROCKWOOL Board Insulation Section Master Guide Specification Page 1 Jan 2017

OptiLiner Banded Liner System, Thermal, Metal Building

EXTERIOR PLANK SERIES SPECIFICATION DATA

SECTION GYPSUM BOARD

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

SECTION THERMAL INSULATION

Geometrik Manufacturing Inc.

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

C. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each product.

Friendly Feel Duct Wrap with KwikStretch Markings. Knauf Data Sheet AH-DS

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Gold Bond BRAND Kal-Kore Plaster Base

FIREBLOCK/DRAFTSTOPPING INFORMATION CODE INFORMATION FOR 1 & 2-FAMILY DWELLINGS FOR WOOD-FRAMED CONSTRUCTION FIREBLOCK

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

A. Description of Work: Work of this section includes self leveling underlayment for interior finish flooring but is not limited to, the following:

Submittal Transmittal

A. Thermal Conductivity: Thicknesses indicated are for thermal conductivity (k-value at 75 degrees F) specified for each material.

SECTION (09800) - Suspended Acoustic Baffles. This Section is based on TECHLITE Accent Linear Ceiling Baffles.

SECTION SPRAY FOAM INSULATION

UNITED STATES COMMERCIAL + RESIDENTIAL Building Insulation Guide

Framed Decorative Panel Systems

Transcription:

Submittal Packages Detailed with Items and Reviewers Tenochca Upgrades Project # 2351 San Diego State University 5500 Campanile Drive San Diego, CA 92182 Tel: 619-594-3740 Fax: 0077-098413-0 Acoustical Author Company Contact Author Package # Trade Importance Kitchell Richard Krauss STRETCHED FABRIC ACOUSTICAL Normal WALL SYSTEM Items Item No. Register No. Rev. Description Type Action Logged By Returned Closed 001 154 0 Acoustical Product Data Approved Reviewers From Company To Company Sent Date DueDate Received Date +/- Action Sent For Kitchell O'Connor Construction 8/11/2016 8/18/2016 Review Kitchell Pacific Cornerstone Architects 8/11/2016 8/18/2016 Review Kitchell Pacific Cornerstone Architects 8/11/2016 8/18/2016 Review O'Connor Construction Kitchell 8/12/2016 8/26/2016 8/12/2016-14 Approved Review O'Connor Construction Kitchell 8/12/2016 8/26/2016 8/12/2016-14 Approved Review þ þ Package Notes Reviewer General Comments Encompass Printed On: 8/12/2016 Page 1 of 1

Submittal Review Project #: 6194A Submittal #: 0077-09 81 33-0 Date: 08/11/2016 4:36:29 PM Submittal Name : Acoustical X Reviewed Resubmit as Noted Not in Compliance with Drawings and Specifications These documents have been reviewed for general conformance with the Contract Documents. This review shall not be construed as direction from the Contractor to the Subcontractor to deviate from the requirements of the Contract Documents. By : Richard Krauss Reviewed Furnish As Corrected Rejected Revise and Resubmit Submit Specific Item For Architect's Record Only This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the shop drawings during this review do not relieve contractor from compliance with the requirements of the plans and specifications. Approval of a specific item shall not include approval of an assembly of which the item is a component. Contractor is responsible for: dimensions to be confirmed and correlated at the job site; information that pertains solely to the fabrication processes or to the means, methods, techniques, sequences and procedures of construction; coordination of his or her Work with that of all other trades; and for performing all work in a safe and satisfactory manner. PACIFIC CORNERSTONE ARCHITECTS, INC. Date: 08/12/16 By: Randy Chumley

CertainTeed Residential and Commercial Products Submittal Form Submitted to: Job Name: Submitted by: Date: This Submittal Form is provided to assist you in specifying and selecting the proper CertainTeed products. Basic product descriptions and performance data are included. For further information or technical assistance, contact your local CertainTeed representative. CertainTeed Corporation, P.O. Box 860, Valley Forge, PA 19482 1-800-233-8990 Visit our web site at: www.certainteed.com/insulation Many of CertainTeed s Manufacturing plants are registered to ISO 9001:2000 standards.

Product Description R-Values and Thicknesses* Applicable Standards Unfaced Sustainable manufactured in widths to permit pressure fit installation. Used with a separate vapor retarder or where no vapor retarder is required or recommended. 38 12 " 21 5½ " 38C* 10¼ " 19 6¼ " 30 10 " 15 3½ " 30C* 8¼ " 13 3½ " Complies with ASTM C665, Type I. Is noncombustible, meeting test criteria of ASTM E136. Thermal 25 8 " 11 3½ " 22 6½ " *Cathedral Ceiling Batt Kraft Faced Sustainable manufactured with a kraft paper facing with a vapor permeance rating of 1.0 or less. Includes stapling flanges. 38 12 " 22 6½ " 38C* 10¼ " 21 5½ " 30 10 " 19 6¼ " Complies with ASTM C665, Type II, Class C, Category 1. Thermal 30C* 8¼ " 15 3½ " 26 8 3 8 " 13 3½ " 25 8 " 11 3½ " *Cathedral Ceiling Batt DryRight Sustainable DryRight batt, faced with MemBrain, the Smart Vapor Retarder, is intended for use in either residential or commercial construction as thermal and acoustical insulation in wood framed assemblies. 38 12 " 19 6¼ " 30 10 " 13 3½ " 30C* 8¼ " 15 3½ " 21 5½ " 11 3½ " Complies with ASTM C665, Type II, Class A, Category 1. Thermal performance determined by Water vapor permeance values are determined by ASTM E96. *Cathedral Ceiling Batt < 2 ) (ASTM E96, Standard Desiccant method) Dry Cup Mean, Relative Humidity=25% 2 ) (ASTM E96, Standard Water method) SpeedyR Kraft Faced Sustainable manufactured with a kraft paper facing with a vapor permeance rating of 1.0 or less. No stapling required. 21 5½ 13 3½ " 19 6¼" Complies with ASTM C665, Type II, Class C, Category 1. Thermal Masonry Wall Sustainable unfaced batts designed for use behind paneling in masonry-type construction where cavity depth is limited by the furring strips. Used with a separate vapor retarder or where no vapor retarder is required or recommended. Nominal R Thickness 6 1¾ " 3 ¾ " Complies with ASTM C665, Type I. Is noncombustible, meeting test criteria of ASTM E136. Thermal *Additional R-values & thicknesses may be available. Contact your CertainTeed representative for more information.

Product Characteristics (continued) Surface Burning Characteristics These products have the following maximum flame spread and smoke developed ratings when tested per ASTM E84: Product Flame Spread Smoke Developed Unfaced 5 0 UltraTherm 5 0 InsulSafe SP 5 5 OPTIMA 5 5 FSK-25 25 50 Basement Wall 25 50 Standard Foil Faced 75 150 MemBrain 20 55 DryRight <25 <50 CertaSpray Open Cell Foam <25 <450 CertaSpray Closed Cell Foam <25 <450 FSK-25, Basement Wall and standard foil-faced insulation products have a critical radiant flux flame propagation resistance equal to or greater than 0.12 w/cm 2. Fire Safety CertainTeed Unfaced Fiber Glass, OPTIMA, InsulSafe SP, and UltraTherm are noncombustible per ASTM E136 test criteria. Many building codes require that foam plastic insulation be covered with an approved 15-minute thermal barrier. Consult local building code officials to ensure the application meets local building codes and regulations. Approximate STC Ratings Wood Frame Partitions With Gypsum Wallboard Facings (1/2" & 5/8") Single studs/single layer facings Single studs/resilient channel Staggered studs/single layer facings Double stud walls/single layer facings Steel Stud Partitions With Gypsum Wallboard Facings (1/2" & 5/8") Single layer facings Double layer one side, single layer other side Double layer each side No 3 1 2" of CertainTeed Fiber Glass (batts or blown) 1/2" 5/8" 1/2" 5/8" 34 35 39 38 39 40 46 50 39 43 50 51 46 45 57 57 No 3 1 2" of CertainTeed Fiber Glass (batts or blown) 2 1 2" Studs 3 5 8" Studs 2 1 2" Studs 3 5 8" Studs 1/2" 5/8" 1/2" 5/8" 1/2" 5/8" 1/2" 5/8" 36 39 36 39 45 47 47 50 39 44 42 47 50 52 52 55 45 48 50 52 54 57 56 58 Guide Specifications for CertainTeed Fiber Glass Thermal and Acoustical s Note to the specifier: Provide information as required; delete inappropriate items and fill in where indicated. This guide specification applies to thermal and acoustical insulation in walls, ceilings and floors. It follows Construction Specifications Institute (CSI) format. Part 1 General 1.01 Work Included State type of insulation and where it is to be installed. 1.02 Related Work State if separate vapor retarder and/or air barrier is to be installed. 1.03 References Include appropriate insulation standards. Part 2 Products 2.01 Acceptable Manufacturers CertainTeed Corporation 2.02 Materials Thermal for (ceilings) (walls) (floors) shall be CertainTeed inches thick, with R-Value of, or for (ceilings) (or other approved location) shall be CertainTeed installed at minimum of inches thick, with bags/1,000 sq. ft. for R-Value of. Sound Control for (ceilings) (walls) (floors) shall be CertainTeed. Acoustical Ceiling Batts over suspended ceilings shall be CertainTeed kraft-faced (3 1 2 R-11) (6 1 4 R-19) Acoustical Ceiling Batts. Part 3 Execution 3.01 Preparation Verify that mechanical and electrical services in (ceilings) (walls) (floors) have been installed and tested and, if appropriate, verify that adjacent materials are dry and ready to receive insulation. 3.02 Installation Installation shall be in accordance with CertainTeed s instructions.

Guide Specifications for CertainTeed Commercial Fiber Glass Products PART 1 GENERAL 1.01 Summary A. This section includes commercial building thermal/acoustical insulation for application to: 1. Exterior building walls; 2. Interior partition walls, shaft walls, and other interior surfaces; 3. Ceiling suspension systems. 1.02 Submittals A. Prepare and submit for approval information as required by the conditions of the contract and Division 1 Submittals sections. B. Submit product data for each thermal and acoustical insulation product specified. 1.03 Quality Assurance A. Installers shall be qualified to perform work of this section and shall be experienced in the performance of installation operations as appropriate to the project. 1.04 Delivery and Storage A. Deliver all insulation materials and accessories to the project site in manufacturer s original, unopened, undamaged packaging, with all identification labels intact. Store in a safe place protected from dust, dirt, moisture and physical abuse before and during installation. PART 2 PRODUCTS 2.01 Approved Manufacturer and Products A. All thermal/acoustical insulation materials shall be in accordance with Division 1 Submittals, manufactured by CertainTeed Corporation, including but not limited to: or Kraft Faced (no tabs). 2. CertaPro Partition Batts, Unfaced. 3. CertaPro Thermal Kraft Faced Batts. 4. CertaPro Thermal Foil Faced Batts. 5. CertaPro Thermal FSK-25 Faced Batts. 6. CertaPro Thermal Extended Flange Batts, FSK Faced. 7. CertaPro Thermal Extended Flange Batts, Black PSK Faced. 8. CertaPro Thermal Extended Flange Batts, White PSK Faced. 9., Unfaced, Kraft Faced. 10. CertaPro Commercial Board, Unfaced, FSK Faced, ASJ Faced. 11. CertaPro AcoustaBoard Black. 12. CertaPro AcoustaBlanket Black. 13. Metal 202-96 (Rev. 2000). 14. Commercial Blanket. B. Where applicable, specify product thicknesses and length/width dimensions so insulation completely fills wall cavities to meet thermal and acoustical performance specifications. C. Specify type of vapor retarder facing to meet water vapor transmission and fire rating specifications. 2.01 Products and Applications A. Curtain Wall : or Kraft Faced (no tabs). 2. CertaPro Thermal Kraft, Foil, or FSK-25 Faced Batts. 3. CertaPro Commercial Board, Unfaced, FSK or ASJ Faced. B. Partition : 1. CertaPro Partition Batts, Unfaced. R-Value: 5.8. C. Interior Cavity Wall : or Kraft Faced. 2. CertaPro Thermal Batts, Kraft, Foil, or FSK-25 Faced. 3. CertaPro Thermal Extended Flange Batts, FSK or PSK Faced. D. over ceiling suspension systems: or Kraft Faced (no tabs). E. for acoustic control in theaters, sound studios, etc.: 1. CertaPro AcoustaBoard Black. 2. CertaPro AcoustaBlanket Black. F. for metal building ceiling and side wall applications: 1. CertainTeed Metal 202-96 (Rev. 2000). 2. Commercial Blanket. PART 3 EXECUTION 3.01 Inspection A. Verify that all insulation may be installed in accordance with project drawings, thermal and acoustical design requirements and fire ratings. B. Confirm that all exterior and interior wall, partition, and floor/ceiling assembly construction has been completed to the point where the insulation may be correctly installed. 3.02 Installation B. Install all insulation in compliance with manufacturer s published instructions and good workmanship so that acoustical and thermal performance requirements are met. 3.03 Safety Precautions A. Properly protect insulation contractor s employees during installation of all insulation. Protection shall include proper attire when handling and applying insulation materials, and shall include but not be limited to gloves, hard hats, disposable dust respirators, and eye protection. B. Conduct all job site operations in compliance with applicable provisions of the Occupational Safety and Health Act and/or local safety and health codes and regulations.