Studies energy efficiency of the renewable sources use considering climate in Latvia

Similar documents
RESULTS OF LONG-TERM ENERGY EFFICIENCY MONITORING OF TEST BUILDINGS UNDER REAL CLIMATIC CONDITIONS

Energy Efficiency and Sustainability of Low Energy Houses in Latvian Climate Conditions

A Testing Ground for Measuring Influence of Building Envelope Materials on Energy Efficiency and Indoor Environment

Analysis of Thermal Comfort Conditions and Actual Energy Efficiency for Different Heating Systems in Test Buildings

ScienceDirect. Comparison of steady-state and in-situ testing of high thermal resistance walls incorporating vacuum insulation panels

Effect of insulation ground on anti-condensation in rural residence

Cost Optimal Retrofitting Of Shopping Malls In Europe

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 72 (2015 ) 27 33

Application of Low Cost Active and Passive Energy Saving Technologies in an Ultra-low Energy Consumption Building

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Retrofit of an historical building toward NZEB

Moisture conditions in passive house wall constructions

Energy impact of ASHRAE s museum climate classes: a simulation study on four museums with different quality of envelopes

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Life Cycle Assessment of energy related building renovation: methodology and case study

Full scale experimental performance assessment of a prefabricated timber panel for the energy retrofitting of multi-rise buildings

ScienceDirect. Energy and environmental monitoring of a school building deep energy renovation in Italy

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Title Inner Wall in Hagia Sophia, Istanbu. Citation Energy Procedia (2015), 78:

Thermal insulation performance of reflective foils in floor cavities - Hot box measurements and calculations

Adaption of the passive house concept in northern Sweden - a case study of performance

S. LONGO. The paper shows analysis of the impact on thermal comfort of natural ventilation in a nonresidential Mediterranean case-study.

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 78 (2015 )

CALCULATIONS OF COST-OPTIMAL LEVELS OF ENERGY PERFORMANCE REQUIREMENTS FOR RENOVATED BUILDINGS AND BUILDING ELEMENTS: A LATVIAN CASE

ANALYSIS OF THE EFFICIENCY OF NON-TRADITIONAL THERMAL INSULATION MATERIALS

THERMAL PERFORMANCE USING RADIANT BARRIER AND PHASE CHANGE MATERIAL IN ROOFS

Thermal Performance of Solar Heating System with Water Floor

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

A preliminary study on the climate adaptive design of green rural houses in west China

Design of a prefabricated concrete slab with PCM inside the hollows

Cost-Benefit Analysis of Dwelling Retrofit Options

Computational and the real energy performance of a single-family residential building in Poland an attempt to compare: a case study

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

ScienceDirect. Simulation based mixed mode building design

Energy consumption and thermal comfort in a passive house built in Romania

ScienceDirect. Thermal Performance Improvement of Prefab Houses by Covering Retro-reflective Materials

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Results from the Application of the Maltese Energy Performance Rating of Dwellings in Malta EPRDM Software to a New Block of Apartments

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Available online at ScienceDirect. Energy Procedia 78 (2015 )

ENERGY EFFICIENT TECHNIQUES AND SIMULATION OF ENERGY CONSUMPTION FOR THE SHANGHAI ECOLOGICAL BUILDING

Available online at ScienceDirect. Energy Procedia 57 (2014 )

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Dynamic facades, the smart way of meeting the energy requirements Johnsen, Kjeld; Winther, Frederik Vilbrad

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

Available online at ScienceDirect. Energy Procedia 91 (2016 )

The Operational and Maintenance Specificity of Heating Systems Depending on the Thermal Inertia of Buildings

Procedia - Social and Behavioral Sciences 216 ( 2016 )

Available online at ScienceDirect. Energy Procedia 81 (2015 )

Available online at ScienceDirect. Energy Procedia 96 (2016 ) 94 99

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Available online at ScienceDirect. Procedia Engineering 113 (2015 )

Experimental investigation of photovoltaic-thermal hybrid solar collector

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 20 26

Roels, Staf ; Bacher, Peder; Bauwens, Geert ; Madsen, Henrik; Jiménez, María José

Zero Energy Building Example in Estonia. Tõnu Mauring

Benefits from energy related building renovation beyond costs, energy and emissions

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Available online at ScienceDirect. Energy Procedia 78 (2015 )

CHAPTER 6 CONCLUSION

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

Investigations of Intelligent Solar Heating Systems for Single Family House

Thermal Environment of Chinese Residential Buildings with Different Thermal Insulation Materials in Hot-Summer-and-Cold-Winter Zone of China

Nocturnal radiation cooling tests

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

Available online at ScienceDirect. Procedia Engineering 169 (2016 )

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Simulation and Energy Analysis of Thermal Environment of Unassisted Passive Solar House

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

EFFICIENCY OF HEAT RECOVERY FROM PIGSTY MANURE

Moisture Risks in Multi-layered Walls - Comparison of COMSOL Multiphysics and WUFI PLUS Models with Experimental Results

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Aalborg Universitet Investigation of Different Configurations of a Ventilated Window to Optimize Both Energy Efficiency and Thermal Comfort

Advanced Design and Building Information Modeling February. Would you like to develop a BIM model of this project? no

IGEN. OCHSNER GMLW 19 - Air Source Heat Pump Performance in Irish Climate. One Year Monitoring Study

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

Potential for Improved Outdoor Comfort by Design in U.S. Climates

Simulation Studies on Performance of Solar Cooling System in UAE Conditions

Analysis of Heat Gain in Computer Laboratory and Excellent Centre by using CLTD/CLF/SCL Method

Estimate the size of the solar and hydro power resources in kw. [5 Marks]

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

Kull, Tuule Mall; Simson, Raimo; Thalfeldt, Martin; Kurnitski, Jarek Influence of time constants on low energy buildings' heating control

Dimensioning a small-sized PTC solar field for heating and cooling of a hotel in Almería (Spain)

Measured temperature and moisture conditions in the roof attic of a one-and-a-half story house Nielsen, Anker; Morelli, Martin

ScienceDirect. Appraising the effect of the primary systems on the cost optimal design of nzeb: A case study in two different climates

STUDY ON TESTING FEASIBILITY OF SOLAR ENERGY IN THE PALESTINIAN TERRITORIES

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Transcription:

Available online at www.sciencedirect.com ScienceDirect Energy Procedia (25) www.elsevier.com/locate/procedia 6th International Building Physics Conference, IBPC 25 Studies energy efficiency of the renewable sources use considering climate in Latvia Saule Sakipova a,b, *, Andris Jakovičs a, Stanislavs Gendelis a a University of Latvia, Department of Physics and Mathematics, Zellu Str. 8, Riga, LV-2, Latvia b E.A. Buketov Karaganda State University, Physical Technical Department, Universitetskaya Str. 28, Karaganda, Kazakhstan Abstract The paper discusses problems of energy supply of buildings using renewable sources given the local climatic conditions. The meteorological conditions in Latvia and Riga for last year were analyzed. In paper shows examples of energy efficient buildings allowing that to provide comfort temperature and indoor air quality. The structure and composition of local building materials, providing good thermal insulation are described. The heating systems for test buildings using renewable energy sources were investigated. The assessment of the energy efficiency of the "air-air" and "air-water" heat pumps is studied. 25 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the CENTRO CONGRESSI INTERNAZIONALE SRL. Keywords: energy efficiency, test buildings, renewable energy sources, energy consumtion, heating system, heat pump. Introduction The continuous increase in prices for electricity, heating and operational expenses on the maintenance of premises arouses increased interest both in the use of renewable energy sources and in development of methods for efficient energy consumption. Actually, it is important not only to be able to produce cheap energy from renewable sources, but also to optimize its use, taking into account the climatic conditions of a particular locality. When constructing * Corresponding author. Tel.: +7-777-999337; +37-2478; fax: +37-673378. E-mail address: sesaule@mail.ru 876-62 25 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the CENTRO CONGRESSI INTERNAZIONALE SRL.

2 Author name / Energy Procedia (25) buildings and residential houses, it is important to use quality thermal insulating construction materials, and besides, to use energy sources effectively. In this regard, during the last decade it becomes urgent to develop "energy efficient" or so-called "passive" houses. The main feature of such a house is low power consumption, which is on average % of the specific energy consumption of most modern buildings [-3]. In developed European countries there are different requirements for a passive house standard. As a rule, the rate of energy use for an object is determined by average heat energy losses per square meter, during a year or the heating season. A perfect passive house must have an independent power supply system, required to support and maintain a comfortable temperature inside the building. The heat generated by the residents and appliances in the house of this type should be enough to heat it, and, if necessary, alternative sources of energy may additionally be used. In order to solve the problems set forth the authors analyzed the features of the climate in Latvia, particularly in Riga, and reviewed the efficiency of renewable energy sources use for power supply to various buildings constructed from a variety of local building materials. 2. Statement of the problem 2.. A brief description of the climate in Latvia The geographical location of Latvia on the coast of the Baltic Sea and the Gulf of Riga largely determines its weather conditions. In general, the climate in Latvia can be characterized as intermediate between maritime and continental. According to long-term observations, the average annual temperature in Latvia is + 5.9 C. The warmest month is July. The average summer temperature is +7 C; the maximum temperature is +2.5 C. The coldest months are January and February; the average temperature is about -4.6 C, while the average minimum temperature is -7.7 C, Fig.. Southern, southwestern and western winds dominate in Latvia. The strongest winds (the average monthly speed about 4 m/s) are observed in November, December and January. The weakest winds (the average monthly speed is about 2.8 m/s) blow in July and August [4, 5]. Figure 2 shows the diagrams of wind speed and solar radiationin Riga. a 7 T, degr.c b T, degr.c 5 3 3 5 2 24 36 48 6 72 84 96 8 2 32 Fig.. Change of air temperature: a) at 7.3.24; b) during January 24, [5]. 5 5 5 days 3 5 7 9 35792232527293 These data were measured on-line at the meteorological station in the Botanical Garden of the University of Latvia, there are every minute changes during the day and month. Analysis of the data shows that in the central part of Latvia, the average annual wind speed is (2 3) m/s, and in Riga it is (.37 2.) m/s. The most part of the territory is characterized by partly cloudy weather and light rain during the year. There are only 4-45 shiny days. Although the potential of the solar energy in Latvia is low, but still it is comparable with many European countries; however, it is not enough to heat the building during the day, and keep it warm at night. In the winter intensity of solar radiation accounts for (.5.8) kw/m 2, in the summer this parameter is 2.6 kw/ m 2. In Riga the climate is mild enough. In winter, it keeps very cold for a short time, there is often thaw weather. However, the heating season lasts about 6 months, so to heat and supply electricity to a house an additional source of energy is necessary.

Author name / Energy Procedia (25) 3 a 4,5 4 3,5 3 2,5 2,5,5 V, m/s 62 V av=.72m/s 8 243 36 4248 54 666 72 7884 9 96 2 8 4 2 26 32 38 Fig. 2.Meteo data at 7.7.24.Every minute change of: a) wind speed; b) level of solar radiation, [5]. b 9 8 7 6 5 4 3 2 SR, W/m 2 62 SR av =27W/m 2 8 243 36 4248 54 6 6672 78 849 96 2 8 4 2 26 32 38 2.2. Experiment conditions To study the thermo-physical properties of the common construction materials made of local raw materials, in the laboratory of mathematical modeling of environment and technological processes of the University of Latvia (LU) five test buildings were built [5]. The test buildings with identical geometrical parameters are located in the same geographical conditions in the Botanical Garden of the University of Latvia. The structure and composition of test buildings construction materials (Fig.3) are follows: AER aerated concrete blocks (375 mm) with flexible stone wool layer on the external side; CER perforated ceramic blocks (44 mm) with flexible stone wool insulation layeroutside PLY modular plywood panels with flexible stone wool filling (2 mm) and fibrolite (7 mm) inside EXP perforated ceramic blocks (5 mm)with cavities filled with insulating granules of polystyrene foam; LOG laminated beams (2 mm) with flexible stone wool insulation layer and wood paneling inside Fig.3. The construction materials structure of test buildings. The materials of the exterior walls are different, but with approximately the same thermo-physical properties. The thermal transmission coefficient U of the walls varies in interval (.5.6) W/m 2 K. The evaluation of thermal insulation properties of the construction materials was carried out in accordance with EN ISO 6946:23 standard. Heating /cooling systems using renewable energy sources were installed in the test buildings. They were a heat pump "air-air" and the system "water-air" with capillary type heat exchanger, read more in [5, 6]. Energy analysis of heating systems data as compared with a conventional electric oil heater through the seasons, taking into account the ambient temperature, was carried out. On average, 38 sensors that measure the air temperature inside the building, pressure, humidity, power of energy consumption, the amount of electricity energy, heat consumption and others were set in each test building. Monitoring of the sensors readings is carried out automatically; data are recorded in the collection unit every minute. Besides, the special measuring equipment is connected to the site of the meteorological station.

4 Author name / Energy Procedia (25) It is not simple to analyze the energy consumption in different buildings with different heating systems. In our opinion, energy efficiency of buildings and heating systems can be most appropriately determined by SPF coefficient, which is determined by the ratio of consumed energy to the amount of produced one. 3. Discussion of results Data on the consumption of electric energy in three test buildings for the period from 2.2.24 to 29.4.24 are shown in Table.Outside air temperature was an average 5.9ºC. During the heating period the temperature of (9 2) C was maintained inside the buildings. Table. Energy consumtion of heating systems. Type of heating system Test building W, (kwh) SPF T out, ºC electric heater CER 287. «air-air» heat pump LOG 9.5 5,9 «air-water» heat pump PLY 6 2.7 The resulting heat can be estimated from the electric heater indications in the CER building; in this case as much energy is produced as it is consumed, that is SPF=.. The same thermal energy is produced in the other two buildings, because there is the same internal temperature. So, the most energy-efficient is the system «air-water» in the test building PLY, because with this system produced energy 2.7 times more energy than it is expended. It is also profitable to use the system «air-air» in a LOG building. Figure 4 shows the results of the assessment of energy efficiency of test buildings in March-April 24, depending on the ambient temperature. Fig.4. SPF assessment using PLY «air-water»heating system data. The lines on the graph indicate the following: PLY-T-ROOM is indoor air temperature; numerical values are given in C on the right; MET-T-AIR.OUT is outdoor temperature, C; PLY-POW is power consumption, the numerical values are shown on the left, W.

Author name / Energy Procedia (25) 5 The analysis of experimental data shows that the energy efficiency ratio depends not only on the ambient temperature, but also on the duration of the heating system operation. The more often it is turned on, as it was in the case of the lowest ambient temperatures in the period from.3.24 to 3.2.24, the greater the index SPF. During the period from 2.4.24 to 3.4.24, when the ambient temperature was quite high, the ratio of energy efficiency is the least, as this heating system did not operate and produced only % of the energy consumed. Fig. 5 shows the dependence of the ratio of energy efficiency on the length of operation of the «air-water» heating system during a day. Fig.5. SPF assessment on the duration of using heating system «air-water». The experiments show that the higher the outdoor temperature, the less the «air-water»heating system should operate in order to achieve the same level of energy efficiency. 4. Conclusion Energy efficiency is dependent on the quality, thermal insulation properties and structure of a construction material. It was established experimentally that the most energy-efficient building is that of LOG type. However, it should be noted that the results are valid only for the climatic conditions in Riga, for the mentioned test buildings and heating systems. However, the study results show that when analyzing the energy efficiency of buildings and heating systems under real operating conditions, it is necessary to consider not only the temperature difference between the outside and inside the building, but also the mode of their work. Acknowledgements This research is done with financial support of European Social Fund, project is realized by University of Latvia, No. 23/27/DP/...2./3/APIA/VIAA/7. References [] Cellura M., Guarino F.; Longo S.; Mistretta M. Energy life-cycle approach in Net zero energy buildings balance: Operation and embodied energy of an Italian case study. Energy and Buildings 72, 24, p.37 38. [2] Cabeza F.L., Castell A., Medrano M., Martorell I., Perez G., Fernandez I. Experimental study on the performance of insulation materials in Mediterranean construction. Energy and Buildings. Vol. 42, Issue 5, 2, p. 63-636. [3] Jakovich A., Gendelis S., Ozolins A., Sakipova S.E. Energy Efficiency and Sustainability of Low Energy Houses in Latvian Climate Conditions. Proceedings of the th Intern. Conf. Energy, Environment, Development and Economics, Greece, 24, p.9-4. [4] Operative information of Latvian Center for Environment, Geology and Meteorology http://www.meteo.lv/meteorologijas-operativainformacija /?nid=459&pid= [5] Project on buildings energy efficiency monitoring in Latvian Climate. 23-25 [online] Available: http://www.eem.lv [6] Dimdiņa, I., Jakovičs, A., Gendelis, S., Kļaviņš J. Testing of Energy-Efficient Building Envelope Materials in Natural Conditions. Proceedings of World Sustainable Energy Days 23, Wels, Austria.