Weathertightness test to BS 6375: Part 1: 2009 on a Beaufort Secure Design Ltd open outward, Bi-folding/ sliding door with standard threshold

Similar documents
Weathertightness test to BS 6375: Part 1: 2009 on a Beaufort Secure Design Ltd open outward, single door with side screen

Weathertightness test to BS EN :2006 +A1:2010 clauses 4.2, 4.5 and 4.14 on a Smart Architectural Aluminium Alitherm 700 reversible window

BS EN :2006 +A1:2010

Wind uplift testing on the Click Fit PV mounting system to MCS012. Prepared for: Gary Bowden Cleaner Air Solutions UK Ltd.

Load testing of a PVC coated handrail system. 25 th March Test report number

Laboratory Airborne and Impact Sound Insulation of a Robust Details Appendix F Floor with PhotonStar LED Ltd. Downlights

Laboratory Airborne Sound Insulation of Stud Walls with Warmcel 500 Insulation. Prepared for:

BS8414 Part 1: 2002 Test on a Phenolic Insulated Rainscreen system. Prepared for: Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 9LA

Testing of Three Ply Floor Protection Product Tensile and Tear Strength

Classification report for roofs/roof coverings exposed to external fire in accordance with BS EN : 2005+A1:2009

Evidence of Performance. Class 4. Class E900. Class C3 / B3. Test Report No PR02. DOMIS d.o.o. Miokovci bb Cacak Serbia

BRE Global Test Report

Test Report. Test Report Debar Ltd. Page 1 of 20

BRE Global Test Report

BRE Global Test Report

TEST REPORT EN : A1:2010

BRE Global Test Report

BRE Global Test Report

BS :2005 test on a Kingspan Benchmark External Wall Insulation System

BRE Global Ltd Watford, Herts WD25 9XX. d+b facades (UK) Ltd. The Packway, Larkhill, Salisbury, SP4 8PY. Customer Services

BRE Global Classification Report

BS 476: Part 3: 2004 test on SureSeal EPDM 1.2mm on a plywood deck

BRE Global Test Report

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Test Report: Fire resistance test in accordance with BS EN :1999 on a nonloadbearing. incorporating Scolmore Doubled Switched electrical sockets

ACOUSTIC PERFORMANCE AND STC RATING OF A PARTITION WALL WITH DOUBLE SOCKETS AND POLYSEAM PUTTY PADS

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

Testing a Prefabricated Floor System. Prepared for: Lee O Connor Director Grants of Shoreditch Ltd. 21 October Client report number

Evidence of Performance

BRE Global Test Report

BRE Global Test Report

TEST REPORT. Report No.: A Rendered to: TUBELITE, INC. Walker, Michigan

BRE Global Classification Report

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: BUILDERS ACCESSORIES, INC.

The Alitherm Plus door system is suitable for domestic and medium duty applications

*) This is a translation of Test Report dated 07 August Window system M 9400 SOFTLINE PLUS Frame material: Aluminium

BRE Global Classification Report

BRE Global Test Report

Draft for Public Comment Australian/New Zealand Standard LIABLE TO ALTERATION DO NOT USE AS A STANDARD

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: ALUMIL US. SERIES/MODEL: M300 Falcon PRODUCT TYPE: Aluminum Horizontal Sliding Window (XO)

1.1.2 All window frames will be Kite marked to indicate compliance with these standards.


Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

Aluminium SLIDING & BI-FOLD DOOR SYSTEMS

Biological testing to classify the natural durability of Eastern white cedar Thuja occidentalis

BRE Global Test Report

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: COASTAL INNOVATIVE PRODUCTS

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

SPECIFICATION FOR Aluminium alloy windows

Client Report : Prepared for : Assessment of energy efficiency impact of Building Regulations compliance. Client report number

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: C.R. LAURENCE CO., INC. SERIES/MODEL: S80 Monterey. TYPE: Bi-fold Door

BRE Global Classification Report

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: FLEETWOOD WINDOWS & DOORS. SERIES/MODEL: Norwood 3070HI OOX PRODUCT TYPE: Sliding Glass Door

BRE Global Test Report

Comparison of UK Window Standards to Canadian Standards

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

CRITERIA FOR TESTING IMPACT & NON IMPACT RESISTANT BUILDING ENVELOPE COMPONENTS USING UNIFORM STATIC AIR PRESSURE

BRE Global Test Report

TEST REPORT. Report No.: B Rendered to: MI WINDOWS AND DOORS, INC. Gratz, Pennsylvania

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: ALL SEASONS DOOR & WINDOW, MFG SERIES/MODEL: A500. TYPE: Double Hung Window

SLIDING AND FOLDING DOOR SYSTEMS

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: MGM WINDOW COMPANY Hendersonville, Tennessee

BRE Global Client Report

INTERNATIONAL WINDOW TEST REPORT

AAMA/WDMA/CSA 101/I.S.2/A440-08

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

TEST REPORT AAMA/WDMA/CSA 101/I.S.2/A440-11

CF 68 Bifold Door ISO9001 ISO50001 ISO14001 ISO16001

TESTING APPLICATION STANDARD (TAS) CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING

TESTING APPLICATION STANDARD (TAS) CRITERIA FOR TESTING PRODUCTS SUBJECT TO CYCLIC WIND PRESSURE LOADING

BRE Global Test Report

DESIGN DOORS TEL:

DESIGN DOORS TEL:

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)

BRE Global Classification Report

Wooden joinery (windows and doors)

Classification of fire performance in accordance with BR 135: Annex B: Prepared for: Alsecco (U.K) Ltd Whitebridge Way Stone Staffs.

A Guide To: Weatherseal selection & specification in Europe. Ensuring Superior performance

CERTIFICATE OF APPROVAL No CF 292 NORMA DOORS TECHNOLOGIES, S.A.

BRE Global Assessment Report

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling

BRE Global Test Report

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Classic-Craft, Fiber Classic, and Smooth Star

BRE Test Report. Load and Slip Testing of 4 types of Paving Light and 1 Smoke Outlet Panels. Prepared for: Marc Parkinson. BRE Watford, Herts WD25 9XX

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

Structural Performance Certification Authorization Report

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: WASHOE EQUIPMENT, INC. DBA SUNOPTICS PRISMATIC SKYLIGHTS

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MI WINDOWS AND DOORS, INC. SERIES/MODEL: 390. TYPE: Sliding Glass Door

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

The Royale Collection Aluminium windows and doors

TEST REPORT. Report No.: E Rendered to: INTERNATIONAL WINDOW Fullerton, California

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 900 Series. TYPE: Out-swing Double Terrace Door

TEST REPORT. Report No.: A Rendered to: DEALERS SUPPLY AND LUMBER CO., LLC Greenville, South Carolina

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America Inc. SERIES/MODEL: VCM/VCE B PRODUCT TYPE: Venting Curb Mounted Skylight

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 6/8 Sliding Patio Door

Technical Report. Report No: R Stonel Oy Ahlmaninkatu 2 E FI Jyväskylä Finland. Project. Stofix Brick Cladding

Transcription:

Weathertightness test to BS 637: Part 1: 2009 on a Beaufort Secure Design Ltd open outward, Bi-folding/ sliding door with standard threshold Prepared for: Mr. Dale Pegler Beaufort Secure Design Ltd 26 August 2009 078 Page 1 of 14

Tested on behalf of BRE by Name Malcolm Pound Position Laboratory Manager and Senior Consultant, Actions, Building Technology Date 13 July 2009 Signature Prepared on behalf of BRE by Name Malcolm Pound Position Laboratory Manager and Senior Consultant, Actions, Building Technology Date 26 August 2009 Signature Approved on behalf of BRE Name Dr. P. Blackmore Position Associate Director of Actions, Building Technology Date 27 August 2009 Signature BRE Garston WD2 9XX T + 44 (0) 1923 664000 F + 44 (0) 1923 664010 E enquiries@bre.co.uk www.bre.co.uk BRE is not UKAS accredited to make opinions and interpretation. Any opinions and interpretations included as part of this report are clearly marked as such. 078 This report may only be distributed in its entirety and in accordance with the terms and conditions of the contract. Test results relate only to the items tested. BRE has no responsibility for the design, materials, workmanship or performance of the product or items tested. This report does not constitute an approval, certification or endorsement of the product tested. This report is made on behalf of BRE. By receiving the report and action on it, the client or any third party relying on it accepts that no individual is personally liable in contract, tort or breach of statutory duty (including negligence). Page 2 of 14

1 Introduction At the request of Mr. D. Pegler of Beaufort Secure Design Ltd, 2 Queenway Meadows, Newport, Gwent, NP19 4SQ, BRE issued proposal number 12191 on 30 June 2009. The proposal was accepted on 30 June and BRE tested a specimen door on 13 July 2009. The tests to methods in BS 637: Part 1: 2009, BS EN 1026¹, 1027² and 12211³ measure the weathertightness of the specimen in terms of air permeability, watertightness and resistance to wind load respectively. Classification of the results is based on BS 637: Part 1: 2009 4 and BS EN 12207, 12208 6, 12210 7. The tests on the specimen were carried out under the BRE Standard Terms and Conditions of Business for testing and to the UKAS BRE Specific Procedures Series F, as BRE Job number 24786 in project number CV317. The tests were witnessed by: Mr. D. Pegler Mr. H. John Beaufort Secure Design Ltd Beaufort Secure Design Ltd Page 3 of 14

2 Details of tests carried out BS 637: Part 1: 2009 specifies that the air permeability test is performed under both positive and negative test pressures and that the average of the measurements defines the results. It also specifies that water tightness test method A is used and that deflections measured during the resistance to wind load test do not exceed 1/10 of the span. The weathertightness test comprised of three parts in the sequence: 1. Air permeability to BS EN 1026: 2000; by application of a series of test air pressure differentials across the specimen with measurement of the air permeability of it at each pressure step. The maximum positive and negative pressure differential was 600 Pa reached in pressure steps of 0, 100, 10, 200, 20, 300, 40 and 600 Pa. 2. Watertightness to BS EN 1027: 2000; by applying specified amounts of water spray to the outside face of the specimen while incrementally increasing the air pressure differential across it. The test pressure, time and position of any water penetration are recorded. The maximum positive air pressure differential was 900 Pa. Pressure (Pa)/time (min) steps were 0/1, 0/, 100/, 10/, 200/, 20/, 300/, 40/ and 600/. 3. Resistance to wind load to BS EN 12211: 2000; by application of a series of positive and negative test air pressures. Measurements and inspections are made to assess relative frontal deflection and resistance to damage from wind loads. The resistance to wind load test includes a deflection test, a repeated pressure test and operational test, an air permeability test and finally a safety test. For the purpose of the resistance to wind load test three test pressures are defined: P1 applied to measure the deflections of parts of the test specimen. P2 0 cycles of pulsating pressure to assess performance under repeated wind loads. P3 applied to assess the safety of the test specimen under extreme conditions. The values of P1, P2 and P3 are related as follows: P2 = 0.P1, P3 = 1.P1. For these tests the values are: P1 = 2400 Pa, P2 = 1200 Pa and P3 = 3600 Pa. Note: The repeat air permeability test is an integral part of the resistance to wind load test and its significance is as an indicator of damage that may occur during that test. Page 4 of 14

3 Classification of results BS 637: Part 1: 2009 classifies the results for products in the UK. For a door to be included in an exposure category the appropriate test pressures for air permeability, watertightness and resistance to wind shall be attained or exceeded. The relevant product standard BS EN 1431-1:2006 8 also states that classification of air permeability is based on the averages of the positive and negative air leakage values at each pressure step. The specimen was tested to a UK exposure category of 2000+ (2400 Pa). The classifications set in BS 637: Part 1: 2009 for a UK exposure category of 2000+ for windows are: Air permeability at Class 2/300 Pa or Classes 3 and 4 when tested to 600 Pa, watertightness at Class 7A/300 Pa and resistance to wind load at Class AE at P1 2400 Pa, P2 1200 Pa and P3 3600 Pa. For Air permeability Clause 4.6 of BS EN 12207 explains the relationship between classifications based on air leakage over the overall area and the length of the opening joint. When this results in adjacent classes (as is the case in these tests) then the most favourable class with lower rate is given. The BS EN classifications are explained below: Air permeability: BS EN 12207: 1999. The classification is based on a comparison of the air permeability of the test specimen related to both overall area and length of opening joint. There are four classes; Class 4 is applicable to the most airtight specimens while Class 1 describes those with most air leakage. To meet any class the measured air permeability of the specimen must not exceed the upper limit at any test pressure step in that class. Watertightness: BS EN 12208: 2000. The classification is based on a comparison of the watertightness of the test specimen related to test pressures and duration of the test. There are nine classes; 1A/1B up to 9A for test pressures from 0 Pa to 600 Pa. For specimens that remain watertight over 600 Pa for minutes a class Exxx is used. The xxx is the maximum test pressure e.g. 70 Pa. To meet any class the specimen must remain watertight for minutes up to and at the test pressure set for that class. Resistance to wind load: BS EN 12210: 1999. The classification is based on a comparison of the resistance to wind loads of the test specimen when subjected to test pressures P1, P2 and P3. There are five classes; 1 up to for P1 test pressures from 400 Pa to 2000 Pa. For specimens that are tested to P1 pressures exceeding 2000 Pa a class Exxxx is used. The xxxx is the actual test pressure P1 used e.g. 2400 Pa. To achieve any class the resistance of the specimen to wind load must meet all the requirements for that class. Note: This report has results for air permeability under positive and negative test pressures and a graph showing the average air permeability for them at each pressure step. Page of 14

4 Test specimen The general details about the test specimen supplied by Beaufort Secure Design Ltd for these tests are given below and in drawings in the Annex of this report. Type: Glazing: Seals: Hardware: Fixings: Drainage: Aluminium frame members with three outward opening glazed door leafs arranged as a bifolding and sliding unit. Reference: Beaufort Secure Design Ltd 2100 mm high x 3000 mm wide Folding Sliding door. All of the door leafs are internally glazed with 4 mm thick clear toughened glass Both of the lights are internally glazed with insulating glass units with 4 mm thick toughened glass and a 20 mm air gap. Snap-in aluminium beads retain the glazing seals and the glazing. Around the door frame indoor edge there is an 8 mm thick brush pile type seal with central plastic fin. Bottom and top of the door frame has a weatherseal that engages with a similar one on the door leafs. The two folding joints have weatherseals front and back of the joint as do the opening joints at the right and left hand ends of the door. The top and bottom of the door leafs have a single row of seal near the outdoor face. All fixing holes have plastic caps fitted. At the right hand stile on the right hand door leaf one handle operates two claw bolts a central bolt and a latch. The key below this handle locks these bolts. On the left hand stile of the middle leaf a recessed handle (spring loaded) operates shoot bolts to the top and bottom of that stile. There are three hinges at each left hand stile on the three door leafs. For these tests the specimen was fixed and sealed into a wood surround frame with screws at the top, bottom and sides. Four slots with plastic hoods in the outdoor face of the threshold and five slots in the channel in the threshold under the closed door leafs. One cut-away connecting front and back channels in the threshold. Dimensions: 2100 mm high x 3000 mm wide (overall). Area: 6.30 m² Length of opening joint = 13.68 m Page 6 of 14

Test rig and preparatory procedures The test specimen was conditioned for at least 4 hours within temperature and humidity ranges specified in the test standards of 10 C to 30 C and 2% to 7% RH respectively. The water temperature in the watertightness test was within the specified range of 4 C to 30 C. The door was mounted in the BRE test rig G, to form one wall of a pressure box, with the outdoor face of the door enclosed in the box. A single spray bar with seven full circular cone nozzles was mounted in the pressure box to apply water to the outside face of the specimen at the rate of 2 L/min per nozzle in accordance with BS EN 1027 spraying method 1A. Transducers were mounted on independent supports to measure deflections of a frame member retaining an insulating glass unit. Deflections were measured on the span at the positions indicated in Figure 1. Page 7 of 14

6 Summary of test results The test results are summarised in Table 1 below for a UK exposure category of 2000+. Figures show detail of the door and detailed results are given in Annex 1. BS or BS EN Air permeability Watertightness Resistance to wind loads Requirements Results Requirement Results Requirements Results BS 637 Class 3 or 4 to 600 Pa Met* the requirements of Class 4 based on the averages of readings in positive and negative tests Class 7A at 300 Pa Met & exceeded the require ments. Class 9A at 600 Pa Class AE2400 P1 = 2400 Pa P2 = 1200 Pa P3 = 3600 Pa All met. Class AE2400 *considering Clause 4.6 of BSEN12207 Table 1. Summary of weathertightness test results Page 8 of 14

7 Conclusions When the specimen Beaufort Secure Design Ltd 2100 mm x 3000 mm open outward Bi-folding/sliding door with standard threshold was tested to the standards described herein it was found to be: When considering Clause 4.6 of BS EN 12207 sufficiently airtight to attain Class 4 air permeability when the averages of the readings under positive and negative test pressures were considered, thus meeting the BS 637: Part 1: 2009 requirements. Resistant to water penetration using method 1A to Class 9A up to and at 600 Pa thus meeting and exceeding the BS 637: Part 1: 2009 requirements. Resistant to wind loads of ±2400 Pa causing deflections less than 1/10 of the span of a door stile. Resistant to repeated pressure cycles of ±1200 Pa and able to sustain the corresponding safety test pressure of ±3600 Pa. The overall classification for resistance to wind load is Class AE2400 meets the requirements of BS 637: Part 1: 2009. 8 References 1. BS EN 1026: 2000. Windows and doors Air permeability Test method. British Standards Institution, London. 2. BS EN 1027: 2000. Windows and doors Watertightness Test method. British Standards Institution, London. 3. BS EN 12211: 2000. Windows and doors Resistance to wind load Test method. British Standards Institution, London. 4. BS 637: Part 1: 2009. Performance of windows and doors Classification for weathertightness and guidance on selection and specification. BS EN 12207: 2000. Windows and doors Air permeability - Classification. British Standards Institution, London. 6. BS EN 12208: 2000. Windows and doors Watertightness - Classification. British Standards Institution, London. 7. BS EN 12210: 2000. Windows and doors Resistance to wind load - Classification. British Standards Institution, London. 8. BS EN 1431-1:2006 Windows and doors Product standard. British Standards Institution, London Page 9 of 14

ANNEX 1. Weathertightness test results positive pressure differential Pa 0 100 10 200 20 300 40 600 Air flow through the specimen m³/h 9.73 14.8 17.0 1.40 18.89 19.94 26.34 30.62 Air flow per unit area of the specimen m³/h.m² 1.4 2.31 2.78 2.44 3.00 3.17 4.18 4.86 Air flow per metre of opening joint m³/h.m 0.71 1.07 1.28 1.13 1.38 1.46 1.93 2.24 Table A1. Air permeability under positive air pressure; test results negative pressure differential Pa 0 100 10 200 20 300 40 600 Air flow through the specimen m³/h 11.24 17.9 23.32 23.03 30.27 3.07 46.98 1.60 Air flow per unit area of the specimen m³/h.m² 1.78 2.8 3.70 3.66 4.80.7 7.46 8.19 Air flow per metre of opening joint m³/h.m 0.82 1.31 1.70 1.68 2.21 2.6 3.43 3.77 Table A2. Air permeability under negative air pressure; test results Pressure differential Pa 0 100 10 200 20 300 40 600 Average air flow per unit area of the specimen m³/h.m² 1.66 2.8 3.24 3.0 3.90 4.37.82 6.3 Average air flow per metre of opening joint m³/h.m 0.77 1.19 1.49 1.41 1.97 2.01 2.68 2.81 Table A3. Averages of air permeabilities under positive and negative air pressures; test results Page 10 of 14

10 Air permeability m 3 /h per m 2 of specimen and per m of opening joint 9 8 7 6 4 3 2 1 m3/h.m2 m3/h.m Neg' m3/h.m2 Neg' m3/h.m Av +/-m2 Av +/-m Class 4 m3/h.m2 Class 4 m3/h.m 0 0 100 200 300 400 00 600 Air pressure differential Pa Figure A1. Air permeability under positive and negative air pressure; test results Page 11 of 14

Watertightness test Pressure differential Pa 0 0 100 10 200 20 300 40 600 Duration Minutes 1 Water leaks Test laboratory conditions: Air pressure 1000 mb. Relative humidity 62.9% at 21.6 C Air temperature 21.6 C. Test chamber air temperature 21.4 C. Water temperature 21. C Table A4. Watertightness test results Resistance to wind load Deflection test at ± 2400 Pa Position deflection measured Positive pressure P1 to +2400 Pa Deflection Negative pressure P1 to - 2400 Pa Deflection mm defl./span mm defl./span Mid height of right hand side stile on middle leaf 8.90 1/222 9.06 1/219 Note: The deflection at the mid-point of a member is measured relative to its ends, e.g. with reference to Figure 1: Deflection at the mid-point = deflection at the mid-point average of deflections at the two ends of the same member. Table A. Deflections measured on right hand stile on middle leaf in the resistance to wind load test at ±2400Pa. Page 12 of 14

Resistance to wind load Repeated pressure test including the second air permeability test Repeated pressure Damage or functional defects 0 cycles to P2 at ±1200 Pa None Table A6. Damage or functional defects after repeated pressures to P2 at ±1200 Pa Second air permeability test under positive air pressures (part of resistance to wind load test) Positive pressure differential Pa 0 100 10 200 20 300 40 600 Air flow through the specimen m³/h 10.7 14.8 17.79 1.6 19.29 20.13 27.40 32.8 Air flow through the specimen as measured previously m³/h 9.73 14.8 17.0 1.40 18.89 19.94 26.34 30.62 Comparison to the air permeability measured previously (see Table A1) After the test pressures P1 and P2 were applied the amounts of air flowing through the test specimen were not significantly different to those measured previously Table A7. Second air permeability test results under positive air pressures Second air permeability test under negative air pressures (part of resistance to wind load test) Negative pressure differential Pa 0 100 10 200 20 300 40 600 Air flow through the specimen m³/h 11.6 18.96 24.32 23.86 30.97 3.99 48.6 3.11 Air flow through the specimen as measured previously m³/h 11.24 17.9 23.32 23.03 30.27 3.07 46.98 1.60 Comparison to the air permeability measured previously (see Table A2) After the test pressures P1 and P2 were applied the amounts of air flowing through the test specimen were not significantly different to those measured previously Table A8. Second air permeability test results under negative air pressures Page 13 of 14

Resistance to wind load - Safety test Safety test Condition after test One pressure pulse to pressure: P3 at then + 3600 Pa No parts became detached and the test specimen remained closed Table A9. Condition of the door after the safety test to P3 at ±3600 Pa Points 1, 2 & 3 where deflections were measured Figure 1. The specimen in the BRE Test rig G ==============REPORT ENDS============= Page 14 of 14