Distribution System Upgrades to Improve Water Quality

Similar documents
SYSTEM ID: KY 10 NARRATIVE DESCRIPTION

Environmental Engineering-I

SYSTEM ID: KY 3 NARRATIVE DESCRIPTION

Thermal and Hydro Power Plant Maintenance Deer Island Treatment Plant

APPENDIX B. WSSC Design Criteria for Water Distribution Systems

CHAPTER 8 WATER SUPPLY SYSTEM

CITY OF ITHACA 108 East Green Street, Ithaca, New York OFFICIAL NOTICE OF MEETING/SPECIAL PRESENTATION CITY OF ITHACA COMMON COUNCIL

VILLAGE OF BEAR LAKE. Water Reliability Study & General Plan Update

TOWN OF MOUNT PLEASANT WESTCHESTER COUNTY, NEW YORK

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

SYSTEM ID: New York Tunnels System

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

Aurora Highlands Civic Association Meeting. Arlington County Department of Environmental Services May 9, 2018

Pipe User Group. Tuesday March 14, Walnut Creek, CA. Matt Wassam

Utilities are constantly striving to

Data Management from Water Utility Perspective

Table of Contents. 3.1 Source Capacity Analysis

City of Moline Water Infrastructure Overview

DRAFT TECHNICAL MEMORANDUM

Public Works Technical Bulletins are published by the U.S. Army Center for Public W VA. Public works Technical Bulletins are intended to provide

SECTION 4 RECOMMENDED DISTRIBUTION SYSTEM IMPROVEMENTS

IDEA Campus Energy 2015

Partnership for Safe Water Distribution System Optimization Program. Barbara Martin, AWWA

Utility Partner Data Report

3 TM Scotchkote TM Spray in Place Pipe 269 Coating. Case Study: Syracuse, New York

Mokapu CIPP Case Study & Innovations in Trenchless Technologies for Wastewater System Rehabilitation

ADVANCED WATER DISTRIBUTION MODELING AND MANAGEMENT

Anew approach to prioritizing water

SECTION WATER DISTRIBUTION SYSTEM

Partnership for Safe Water: Distribution System Optimization Program. Adam Feffer San Jose Water Company November 8, 2017

Bruce Power Pipeline Assessment Workshop. May 31, 2018

MUNICIPAL WASTEWATER PUMP STATION DESIGN PROBLEMS AND SOLUTIONS Jeff Chapin, P.E. Dewberry 8401 Arlington Boulevard Fairfax, VA 22032

Trenchless and Dry Watermain Rehabilitation using Tomahawk in Victoria and Vancouver BC

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

OTCO 12/11/13 Water Audits Meter Testing & Leaks

Why does my water bill cost so much?

Providence Water. Water Main Rehabilitation 2019 Project Overview. Marieville, City of North Providence

Hydraulic Modeling and System Optimization

Cured-in-Place Pipe (CIPP) for Pressure Pipe. Presented by: Mike Moore

ICC-ES Report. PMG-1009 Reissued 10/2017 This report is subject to renewal 10/2018 EPIPE EPOXY LINED PIPING SYSTEM ACE DURAFLO SYSTEMS, LLC

Presentation Outline ENERGY CONSERVATION: 10/20/2017

SECTION C10 CLEANING AND CEMENT LINING GENERAL

CEE 371 Fall 2009 Design Problem 1 (work in teams of 3) DESIGN OF AMHERST TRANSMISSION MAIN

About Me. Overview. Seattle Regional Water System. Seattle Regional Water System. Water System Analysis and Design at Seattle Public Utilities

Massachusetts Water Resources Authority

Drinking Water Systems Regulation (O. Reg. 170/03) 2018 Annual Report

What Tool is the Best Tool?

Business Plan: Drinking Water Supply

Appendix A EXAMPLE COLLECTION SYSTEM PERFORMANCE INDICATOR DATA COLLECTION FORM

CHAPTER 3 INTRODUCTION TO TREATMENT PROCESSES

Pipe-Bursting Success with AC Pipe

Water Utility Science Water Math and Hydraulics 050. Name: Date:

Advances in Condition Assessment Technologies for Pipelines

Hydraulic Modeling, PUDs & Managing Water System Growth

Presenter: Peter C. Gorham, P.E. Director of Engineering

Pipeline Condition Assessment Technology

Water Distribution System Calibration Report

TOWN OF RICHMOND PRELIMINARY ENGINEERING REPORT UPDATES FOR WATER STORAGE IMPROVEMENTS DECEMBER, 2013

WATER MAIN EXTENSION DESIGN REQUIREMENTS

Water Systems for Livestock. Joe Zulovich Extension Agricultural Engineer Commercial Agriculture Program

System-wide Sewer Rehabilitation: Efficiency in Design. May 5, 2011 OWEA Collection Systems Specialty Workshop Eric Dunn, PE Brown and Caldwell

Fiber Reinforced Cured-in-Place Rehabilitation Under an Interstate

Soil Improvement by Compaction Grouting

Cerro Gallina Water Distribution Systems

Diagnostic Method on Cast Iron Pipes JWRC

Amesville Water System

Pump Station No. 1 and Storage Tank

EO = IHP= The efficiency of a pumping plant is calculated as follows:

South Carolina B Operator Study Guide

Ivins City Standard Specifications for Design and Construction Part 2 Engineering and Design Standards

CHAPTER 8 CAPITAL IMPROVEMENT PLAN

ITEM 432 TUNNEL CONSTRUCTION

Replacing an Existing Elevated Storage Tank on the Same Site

WATER LOSS CONTROL PROGRAMS

This is a digital document from the collections of the Wyoming Water Resources Data System (WRDS) Library.

Design Criteria for Walnut Street Emergency Bypass Force Main Jacksonville, FL

ADDENDUM NO. 3 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

DRINKING WATER CONSTRUCTION PERMIT APPLICATON

Solving the Mystery of Non-Revenue Water in High Point

Request for Proposals for Professional Engineering Services for the Front Street Pump Station Upgrade

Inland Pipe Rehabilitation. August 17 OAWWA Canton, OH

PIPELINE CONDITION ASSESSMENT & CLEANING DEVIL IS IN THE DETAILS CITY OF DE SOTO, KANSAS RAW WATER MAIN

NRDCA 300 PROCEDURES TO DETERMINE THE ACCURACY OF MATERIAL MEASURING EQUIPMENT FOR LIGHTWEIGHT INSULATING CONCRETE

Calculate the Costs of Piping System Elements

Session 2 Pump Selection. Mark Markham, P.E. Gresham, Smith and Partners September 14, 2017

B. Stipulated Price (Lump Sum). If Contract is Stipulated Price Contract, payment for work is in this Section is included in total Stipulated Price.

San Antonio Water System Standard Specifications for Construction ITEM NO. 813 WATER SERVICE FOR FIRELINES

Task 5. Christopher Mack Zack Kaldy MET 330 Fluid Mechanics November 8, Purpose

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

SPECIAL SPECIFICATION 5787 Manhole Rehabilitation

Exploration of Utulei Clarigester #1 for Facility Upgrade

SUPPLEMENTAL SPECIFICATIONS TO STANDARD SPECIFICATIONS FOR WATER MAIN AND SERVICE LINE INSTALLATION NO. 2611

EXISTING SYSTEM ANALYSIS

Vapor Extraction / Groundwater Extraction (VE/GE) System Initial Report

There are many technologies available for

LADWP WATER INFRASTRUCTURE PLAN

Proposed Construction of Public Water Supply System for the Village of East Williston Presented by Paul J. Granger, P.E.

Draft. Saipan Final Water Project List

SECTION GROUND STORAGE TANK

Figure 1. Report of Inspection Process Flowchart.

Transcription:

Distribution System Upgrades to Improve Water Quality Christopher Evans, P.E., Hatch Mott MacDonald

Outline Replace Water Lines Project Project Purpose Study Phase Utility Source Evaluation Elevated Storage Tank Evaluation Plumbing System Evaluation Distribution System Evaluation Hydraulic Model Design Phase Construction Phase Conclusions

Harrisburg, Pennsylvania Vicinity Project Driver Brown Water Quality Complaints Consecutive Distribution System Purchase Water From Utility Booster Pump Station / Chlorine Booster Station 250,000 Gallon Elevated Storage Tank Business Campus Established in 1947 Project Purpose Business Model Changes -Large Reduction in Water Demand

Project Scope Project Purpose 20,040 Linear Feet of Distribution System Investigate Condition 6 Buildings (18 Stories) - Investigate Plumbing Condition Identify Source of Brown Water Quality & Design Upgrade Utility Source Evaluation Elevated Storage Tank Evaluation Distribution System Evaluation Plumbing System Evaluation

Site Plan Project Purpose Booster Pump Station Service Connection Elevated Storage Tank

Site Plan Project Purpose Booster Pump Station Service Connection Elevated Storage Tank Blue Buildings Brown Water Quality Issues

Study Phase Utility Source Evaluation CCR Primary Contaminants Normal Ranges No Apparent Discolored Water Source

Study Phase Utility Source Evaluation CCR Secondary Contaminants Fe & MnNormal Ranges ph Abnormally High

Utility Source Evaluation Distribution Samples Fe Normal Range 0.01 to 0.04 ppb MnNormal Range 0.00 to 0.04 ppb Elevated Storage Tank Evaluation Recent inspection No solids accumulation Interior coating needed replacement Tank not considered source Tank scheduled for replacement Study Phase

Water Quality Sampling Event Service Connection Samples Fe (Total) 0.48 ppm Study Phase Mn 0.02 ppm 10 Sample Locations Plumbing & Distribution System Fe (Total) Range 0.48 to 4.8 ppm MnRange 0.02 to 0.33 ppm

Plumbing System Evaluation Study Phase Galvanized Pipe - 60 Years of Service

Distribution System Evaluation Bone Yard Study Phase Transite Pipe - 60 Years of Service

Distribution System Evaluation Study Phase Condition Assessment Spool Piece Unlined Cast Iron Pipe - 60 Years of Service

Distribution System Evaluation Limited Distribution System Understanding Study Phase Pipe Material: Yes Pipe Diameter: Yes Interior Lining: No Water Quality: Soil Conditions: Break History: No No No Exterior Coating: No Non-Revenue Water: No Pipe Condition: No Renewal Rate: No Year Installed: 30 Year Accuracy Construct Distribution System Map / GIS Database

Distribution System Evaluation Study Phase Transite (ACP) 1947 Unlined Metallic After 1947 DIP Cement Lined After 2000

Distribution System Evaluation Study Phase Transite (ACP) 1947 Unlined Metallic After 1947 DIP Cement Lined After 2000 Blue Buildings Brown Water Quality Issues

Hydraulic Model Study Phase Diameter Length (ft) < = 4" 3,955 6" 4,880 8" 2,915 10" 3,525 12" 4,765 Total Pipe 20,040

Hydraulic Model C Value Tests Gauge Health Calibrate Model Study Phase

Hydraulic Model C Value Tests Start 10 Minutes Study Phase

Hydraulic Model C Value Tests Test No. Pipe Material Pipe Diameter Study Phase Calculate d C-Value Design C-Value 1 Asbestos-Cement 8" 126 140 2 Cast Iron 12" 32 100 3 Cast Iron 10" 40 100 4 Cast Iron 8" 53 100 5 Cast Iron 10" 40 100 6 Asbestos-Cement and Cast Iron 6" 83 N/A Hazen and Williams Friction Factor C

Study Phase Hydraulic Model Existing Available Fire Flow Maximum Day Demand 20 psi Min. Pressure Available Fire Flow 12 of 36 < 1,500 gpm

Study Phase Hydraulic Model Proposed Available Fire Flow Yellow = Proposed Cleaning & Lining Fire Flow > Domestic Demand Maximum Day Demand 20 psi Min. Pressure Available Fire Flow All 36 > 2,500 gpm

Recommended a Tiered Approach Tier 1 Water Quality Monitoring Program Baseline Water Quality Monitor Upgrade Water Quality Improvements Tier 2 WatermainUpgrades Fire Flow > Domestic Demand Watermains Oversized for Domestic Demands 6-inch Diameter and Larger Cleaning & Lining 4-inch Diameter and Smaller Replacement Tier 3 Building Plumbing Upgrades Select highest priority building Design Phase

Why Cleaning and Lining? Pros Cost Savings Time Savings Less Disruption Typically Cheaper to Repair Than Replace Pipe Design Phase Cons Risk Unknown Subsurface Conditions Unknown Pipe Condition Pipe Diameter Increase Rehabilitation Cost Savings Increase

Cleaning & Lining Project Requirements? Access Pits Every 500 to 700 Linear Feet Access Pit Typical Locations In Line Valves Side Line Mains Hydrant Laterals Fittings 22 ½ to 90 Degree Elbows Pipe Diameter Change Design Phase

Recommendations Design Phase Phased Construction Rehabilitation by Cleaning and Lining 7,500 linear feet of Cleaning and Cement Mortar Lining 1,200 linear feet of service connection replacement Base Bid Bid Alternates to control contract upper limit Source: Heitkamp, Inc.

Install Bypass Pipe Disinfect Bypass Pipe / Bacteria Test Install Bypass Service Connections Bypass Hydrant Construction Phase Bypass Service Connection

Excavate Access Pits Construction Phase Isolate Water Main Remove Water Main From Service Cut Water Main At Access Pits Rehabilitate Water Main Cleaning & Cement Mortar Lining

Construction Phase Cleaning Scrapers Tuberculation Removal at Access Pit

Repair Water Main At Access Pits Disinfect Water Main / Bacteria Test Restore Water Main Service Connections Remove Bypass Construction Phase Road Restoration At Access Pits

Rehabilitation Versus Replacement Project Specific Comparison Recommended Conclusions Cleaning & Cement Mortar Lining Cost Savings Accomplished Client Goals of Reducing Brown Water Quality Extends Watermain Service Life Client In Process of Removing Bottled Water Stations

Acknowledgment Herb Spencer, Shannon Chemical Corporation HMM Staff Jeff Abrams Vince Manners Kate Greising Mike DeNichilo

Questions Christopher A. Evans, P.E. Associate Hatch Mott MacDonald The Public Ledger Building, Suite 1040 150 South Independence Mall West Philadelphia, PA 19106 P: (215) 399-1159 F: (215) 627-2278 M: (215) 668-1746 christopher.evans@hatchmott.com