ICC INTERNATIONAL, MECHANICAL CODE 2012 edition

Similar documents
ORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

APPLICATION FOR FINISHED BASEMENT PERMIT

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Advanced Ventilation for Residential applications FBC Res 2010.

ORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

Chapter 2: Foundation

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Village of Glen Ellyn Basement Remodeling Project Guidelines

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

Supplementary Standard SB-12. Energy Efficiency For Housing

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training

IECC Residential Significant Changes Summary. Tier I

Questar ThermWise Duct Technical Specifications

Department of Public Safety and Corrections Uniform Construction Code Council. Uniform Construction Code (LAC 55:VI.301)

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS

NAHB s Recommendations on Critical 2015 ICC Code Change Proposals

2018 IECC Residential Provisions with Corresponding IRC Sections

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Residential Basement Finish Guide

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

Standards for Jackson EMC s Right Choice Program Revised: June 2011

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

Energy Efficiency Requirements 9.36

Avenue, NW, 6`h Floor, Washington, DC 20001, is adopted by reference and

Energy Efficiency For Housing

UNIFORM CONSTRUCTION CODE (UCC) BUILDING PERMIT APPLICATION RESIDENTIAL NEW CONSTRUCTION AND/OR IMPROVEMENTS

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

Energy Efficiency For Housing

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Air Sealing for 5 ACH 50

GENERAL MECHANICAL SYSTEM REQUIREMENTS

Island County Noise Zone Maps Adopted with Ordinance C [PLG ] August 12, 2002 Approved by WA State Building Code Council November 26, 2002

County of Yolo Development Services Building Inspection Division

2014 British Columbia Building Code Changes

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

G59 12: Final Decision AMPC1

UNIFORM CONSTRUCTION CODE (UCC) BUILDING PERMIT APPLICATION RESIDENTIAL NEW CONSTRUCTION AND/OR IMPROVEMENTS

2006 INTERNATIONAL MECHANICAL CODE

$ Plan Review Fee when Permit Application is submitted BASEMENT REMODEL BUILDING PERMIT APPLICATION. Status Sticker OFFICIAL USE ONLY

Recommended Amendments to the

fort collins building & zoning

RESIDENTIAL MECHANICAL/FIREPLACE

2018 IRC Sections R303 through R310 Building Planning II

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Andy Schreder CBO Building Official for St Francis, Nowthen

IRC 2012 Key Changes

Administrative Changes

CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

The following chapters or articles of the New Jersey electrical subcode are amended as follows:

Recommendations on Proposed International Code Changes

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

Minimum Requirements for Residential Occupancy Codes and FAQs

INTERNATIONAL Mechanical Code CODE ALERT!

Basement Renovation Guide For Residential Dwellings

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.

780 CMR: 9 th Edition Massachusetts State Building Code. Presented to: BSA Codes Committee. DATE: January 20, 2016

General Residential Code Requirements

General Residential Code Requirements

NOTICE OF ADOPTED AMENDMENTS

Plan Check & Field Inspection Guide

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

Major Texas Energy Code Changes (CZ3) TexEnergy Solutions August 30 th, 2016

Residential Accessory Structures & Room Additions

* RESIDENTIAL PLAN REVIEW *

SOUTHERN NEVADA AMENDMENTS TO THE 2018 UNIFORM MECHANICAL CODE

Supplementary Standard SB-12. Energy Efficiency For Housing

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

2015 Proposed Residential Code with Amendments

BUILDING CODES & DESIGN CRITERIA

BILL NO ORDINANCE NO Sponsored by: Mayor Hennessy

NC 2009 Residential Code changes (Highlights on changes between the 2006 and 2009 NC Residential Code)

Recommended Amendments to the 2012 International Residential Code (IRC)

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

2012 INTERNATIONAL ENERGY CONSERVATION CODE ADOPTION TOOLKIT OCTOBER 2012

General Residential Code Requirements

SOUTHERN NEVADA AMENDMENTS TO THE 2012 UNIFORM MECHANICAL CODE

CHECKLIST Inspecting a Garage

Crawl Space Moisture Control

GENERAL MECHANICAL SYSTEM REQUIREMENTS

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

CODE ACTION AMENDMENTS

Boulder City NV Prepared by (Print Name) Signature Date

Elko County Building & Safety Division

RESIDENTIAL REMODELING AND BASEMENT FINISH

INTERIOR ENVIRONMENT

R vertical and horizontal.

Hardin County Planning and Development Commission

Transcription:

City of Elmhurst AMENDMENTS to the ICC INTERNATIONAL, MECHANICAL CODE 2012 edition GENERAL AMENDMENTS Table of Contents 1. Applicability 2. Conflicts 3. General Amendments 4. Energy Efficiency SPECIFIC AMENDMENTS to the Sections of the IMC 2012 5. Fuel Fired Appliances 6. Section 304.6 Private Garages - Furnaces 7. Section 306.3 Appliances in Attics 8. Section 306.4 Appliances Under Floors 9. Section 403.3 Ventilation Systems 10. Section 504.6 Domestic Clothes Dryer Ducts 11. Section 602.3 Stud Cavity and Joist Space Plenums - Not Permitted 12. Section 603.5 & 603.5.1 Gypsum Ducts Not Permitted 13. Section 910 Floor Furnaces Not Permitted 14. Section 922 Kerosene and Oil-Fired Stoves Not Permitted 15. Chapter 15 Referenced Standards - adopted 16. Appendix A adopted 17. Rule Making Authority 18. Matters not provided for 1

City of Elmhurst AMENDMENTS To the ICC INTERNATIONAL, MECHANICAL CODE 2012 edition 1. APPLICABILITY The City of Elmhurst Amendments, Zoning Ordinance, and Municipal Ordinance and all of the adopted model codes shall be applicable to the planning and construction of all projects within the City. 2. Conflicts Whenever two codes are in conflict, the more stringent requirement shall govern. 3. GENERAL AMENDMENTS a) Attic furnaces and crawlspace furnaces are not b) Concrete Pad When the floor construction is combustible all gas fired furnaces shall be placed on a minimum of 2 of concrete or on a solid precast concrete pad or on 2 layers of DURA ROCK. (The precast pad may be under the furnace only, and extend a few inches beyond the perimeter of the unit s footprint.) Furnaces may be placed directly on concrete basement floor slabs. c) Air conditioning equipment, including pads, condensing units, heat pumps, etc. are not permitted in the required sideyard setbacks. (per Zoning Ordinance) d) All dryer vents shall be metal or metal flex. Non-metallic vents for dryers are not See Section 504.6.1. e) All ductwork shall be a closed system and in compliance with the International Mechanical Code Section 603. Use of a stud space or joist 2

space for a supply or plenum return is not Gypsum ducts are not Delete Section 603.5.1. f) Provide a 1-1/2 precast concrete pad under all furnaces which are set on a wood floor. (or use 2 layers of ½ DURA ROCK or a 2 Thickness of poured concrete). g) All bathroom, shower and powder room exhaust fans shall have insulated ductwork, R-6, unless ducts or portions thereof are located completely inside the building envelope. (reference International Energy Code, Section R403.2.1) 4. ENERGY EFFICIENCY This code (IMC) shall comply with all of the requirements of the International Energy Conservation Code 2015 edition. (as required by the State of Illinois) SPECIFIC AMENDMENTS to the Sections of the IMC, 2012 edition 5. Fuel Fired Appliances See Section 303 for approved and prohibited locations. a) Section 303.3 Prohibited locations Fuel-fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces. 1. Sleeping rooms 2. Bathrooms 3. Toilet rooms 4. Storage closets 5. Surgical rooms b) Exception: This section shall not apply to the following appliances: 1. Direct-vent appliances that obtain all combustion air directly from the outdoors. 2. Solid fuel-fired appliances, provided that the room is not a confined space and the building is not of unusually tight construction. 3. Appliances installed in a dedicated enclosure in which all combustion air is taken directly from the outdoors, in accordance with Chapter 7. Access to such enclosure shall be through a solid door, weatherstripped in accordance with the exterior door air leakage requirements of the International Energy Conservation Code and equipped with an approved self-closing device. (hydraulic closer required) 3

6. Section 304.7 Private Garages - furnaces Appliances located in private garages and carports shall be installed with a minimum clearance of 6 feet above the floor. EXCEPTION: The requirements of this section shall not apply where the appliances are protected from motor vehicle impact and installed in accordance with Section 304.3 of the IMC. 7. Section 306.3 Appliances in Attics Attic furnaces are not 8. Section 306.4 Appliances under floors Furnaces in the crawlspace or other appliances under floors are not 9. Section 403.3 Ventilation Systems Ventilation Systems shall be designed to provide the minimum ventilation rates for the occupancy classifications presented in Table 403.3. 10. Section 504.6 Domestic clothes dryer ducts Clothes dryer exhaust ducts shall be constructed of galvanized steel or aluminum. Clothes dryer transition ducts used to connect the appliance to the exhaust duct system shall be limited to single lengths not to exceed 8 feet. Transition ducts shall be metal flex and shall not be concealed within construction. The maximum allowable exhaust duct length shall be determined by one of the methods specified in Section 504.6.4.1 or 504.6.4.2. 11. Section 602.3 Stud cavity and joist space Plenums Not Permitted Delete this section in its entirety. Stud cavity and joist space plenums are not 12. Section 603.5.1 Gypsum ducts not permitted Delete this section in its entirety. The use of gypsum board to form ducts is not 13. Section 910 Floor Furnaces not permitted Delete this section in its entirety. Floor furnaces are not 14. Section 922 Kerosene and Oil-fired Stoves not permitted Delete this section in its entirety. Kerosene and oil-fired stoves are not 15. Chapter 15 Referenced Standards All of the referenced standards listed in Chapter 15 of the IMC 2012 edition are hereby adopted by the City of Elmhurst. 4

16. Appendix A Appendix A of the IMC 2012 edition is hereby adopted by the City of Elmhurst. 17. Rule Making Authority The Code Official shall have authority as necessary in the interest of public health, safety and general welfare, to adopt and promulgate rules, regulations and policies to interpret and implement the provisions of this code to secure the intent thereof and to designate requirements applicable because of local climatic, other unique conditions or extenuating circumstances. Such rules shall not have the effect of waiving structural or fire performance requirements specifically provided for in this code of violating accepted engineering practice involving public safety. 18. Matters not provided for Any requirements that are essential for the structural, fire or sanitary safety of an existing or proposed building or structure, or for the safety of the occupants thereof, which are not specifically provided for by this code, shall be determined by the code official. The Code Official shall have the authority to enforce such requirements. END Amendments-ICC-NATL-Mechanical.section5 July 2, 2014 REVISED 2.8.16 5