Gas Filtration Catalogue

Similar documents
Dräger Gas Filtration SUPER CLEAN GAS FILTERS. Dräger: Technology for Life

Super Clean TM Gas Filters

Super Clean Gas Filters Simply the best

Super Clean Gas Filters Simply the best

TTE N TTE N

Capillary GC Troubleshooting: a Practical Approach

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

MATERIALS OF CONSTRUCTION

Equipment. Description. Features. Ordering Information. indicating oxygen trap Series 6200

Alumina BOND/MAPD PLOT Columns!

2014 Chromatography Supplies & Instruments Catalog - Gas Purifiers

Hydrogen Generators for Fuel Gas

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Analytical Gas Systems Product Catalog

OXYGEN TRAPS MOISTURE

Gas Generators. Parker Balston

APPLICATIONS BENEFITS INTELLIGENT

Hydrogen Generators Flow Capacities up to 500 cc/min

SCION GC Series. The Gas Chromatographers Choice for Separations

Fast Refinery Gas Analysis Using the Agilent 490 Micro GC QUAD

Agilent Consumables Improve Performance with Shimadzu GC/MS

Hamilton PRP Polymeric Columns

Varian Supplies/Parts. GC Accessories. Septum Nut. Merlin Microseal Kit

order:

Content Page OPTIC Liners OPTIC 2 OPTIC 3 OPTIC-4 LINEX PHASER

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

PROCESS ANALYZERS FOR PURIFIED BULK GAS QC/QA: ENTERING THE PPT RANGE

GC Consumables Product Guide C184-E034

Markes International Thermal Desorption G8125A, G8126A, G8127A, G8128A, G8131A, G8132A, G8136A, G8133A, MKI-MicroC Site Preparation Checklist

For highest levels of purity

PACK YOUR OWN CAPILLARIES FOR HPLC AND MASS SPEC

Agilent Gas Phase Solutions

VWR ANALYTICAL GAS GENERATORS FOR CHROMATOGRAPHY APPLICATIONS

Gas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator

Gas Chromatography SSI-GC-003

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

( ) IONPAC ATC-HC ANION TRAP COLUMN

ANALYTICAL GAS GENERATORS

PerkinElmer Supplies/Parts. GC Accessories. Autosampler Syringes

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

ANALYTICAL GAS GENERATORS INNOVATIVE GAS SOLUTIONS FOR YOUR LAB

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

TRACE ANALYTICAL. ta7000 Series UHP Gas Purity Monitors At the critical link in your manufacturing process. Features /Benefits

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas

Electron Capture Detector for GC-2010 Plus

Field Tests of Chloroform Collection/Analysis Methods

Meet the airgc. Ambient air carrier. Top performance. catalytics accelerated

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

Preparation of Reagent Water

TRACE 1300 and TRACE 1310 Gas Chromatographs Dual Detector Microfluidics Installation Guide

Quick Reference Guide. Supplies for CTC GC and HPLC Autosamplers

Liners and consumables for OPTIC Inlet. Liner Selection Guide

FINAL REPORT. Participants in the reported tasks 1. Ravi Subramanian 2. Manoranjan Misra 3. Kent Hoekman

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC June 2014

AUTOMATIC PEROXYACETYL NITRATE (PAN) ANALYZER

Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author.

Agilent MetaCarb 87H Organic Acids Column H + Form User Manual Part No. A5214

Isotope Ratio MS. Continuous Flow. Consumables and Spare Parts for Thermo Scientific Elemental Analyzers

Select Al2O3 MAPD : a new Inert Al2O3 column for the trace analysis of polar reactive hydrocarbons.

40% savings SS /8" SS nut (20) SS /4" SS nut (20) SS /8" SS front ferrule (20) SS

DETECTORS Dry Electrolytic Conductivity Detector - DELCD. Overview

Agilent Ultimate Plus Fused Silica Tubing

Miniature Helium Purifier and Nitrogen Purifier Instruction Manual

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

for Acclaim Carbamate Column

Please enclose a item wise compliance report along with the technical bid.

HPLC. Chrompack ChromSep Cartridge System

Gas Chromatography Assignment Chem 543/443

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer

C146-E096 TD-20. Shimadzu Thermal Desorption System

0.01 Micron Membrane Filters

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Ultra High Purity Hydrogen Generators

Continuously Regenerated Trap (CR-TC 500, Capillary)

A Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis. Application. Authors. Abstract.

Heated FID OVF Portable THC/TVOC Analyzer

Autosampler Supplies for Agilent GC and HPLC Systems with CTC Autosamplers

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

Ensure high performance chromatography by using particle free mobile phases and sample solutions

TVOC Heated FID VE 7

Laboratory Gas Generators

mdi Filters for Sample Preparation

ASI MODEL DM 100 SERIES DILUTING MODULES

Large Valve Oven Analyzers for Refinery Gas Analysis. ASTS 2015 Houston Shannon Coleman Application Specialist Agilent Technologies

Corn Syrup Analysis E-1a- 1. ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

Hydrogen Generators. Zero Air Generators

Introduction Ron Majors is a Senior Scientist at Agilent. Bill Champion is a chemist in Agilent s HPLC Columns tech support group.

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

Line filters LINE FILTERS

INDUSTRIAL AND ULTRA PURE GAS PURIFICATION

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

TDLAS. Application Note. Tunable Diode Laser Absorption Spectroscopy (TDLAS) for Carbon Dioxide Measurements In Natural Gas Processing

Contract Laboratory Program (CLP) Pesticide Analysis with 0.18 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas. Application.

Agilent Max-Light Cartridge Cell Information for G4212A and G4212B DAD

Formulas: See Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1. METHOD: 2555, Issue 1 EVALUATION: PARTIAL Issue 1: 15 March 2003

Gas Chromatograph. GC-8A Series C184-E016B

C184-E016. GC-8A Series. Shimadzu Gas Chromatographs

Transcription:

Gas Filtration Catalogue

2 SHIMADZU GAS FILTRATION CATALOGUE ABOUT SUPER CLEAN GAS FILTERS Cartridge systems make changing gas filters quick and easy. A base plate allows cartridges to be exchanged without introducing oxygen. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process WHY GAS PURITY IS IMPORTANT Carrier gas should contain less than 1 ppm of oxygen, moisture, or other trace contaminants, to prevent column degradation, increase column lifetime, and decrease stationary phase bleed. The expense of using high-purity gases in combination with carrier gas line purifiers will be offset by longer column lifetime and less GC maintenance. Contaminants cause ghost peaks to appear during temperature programming and degrade the validity of analytical data. Make-up gas also should be contaminantfree, or baseline fluctuations and excessive detector noise can occur; detector gases should be free of water and hydrocarbons, or excessive baseline noise can result. Gas purifiers remove these contaminants from gas sources, thereby improving system performance.

SHIMADZU GAS FILTRATION CATALOGUE 3 GAS FILTER SYSTEM COMPONENTS BASE PLATE Connecting unit with in- and outlet connectors for the gas line and two spring-loaded check valves that automatically start the flow of gas once a filter is installed. FILTER CARTRIDGE The filter cartridges are made of glass to prevent diffusion, and protected by a plastic housing for safety. The PTFE seals at the base of the Filter will only be punctured during installation on the base plate. UNIVERSAL RING NUT The Universal Ring Nut is used for mounting a filter cartridge or flush-cap to a base plate. It can also serve as a mounting point for the Electronic Maintenance Indicator device. ELECTRONIC INDICATOR Optional Electronic Maintenance Indicator device warns when scheduled replacement or maintenance is due. WALL MOUNT BRACKET SET Optional wall mounting brackets to mount a base plate to a wall.

4 SHIMADZU GAS FILTRATION CATALOGUE CONNECTION DIAGRAMS GC / MS (ITD/MSD) Carrier Gas GC MS Triple Filter 226-50710-00 1 1 Position Base plate 226-50771-00 1 Kit Part Number 226-50751-00 TOC Analyzer Carrier Gas TOC Analyzer CO 2 / Moisture Filter 226-50759-00 1 1 Position Base plate 226-50771-00 1 Kit Part Number 226-50740-00 GC / ECD Carrier Gas Nitrogen GC Triple Helium Filter 226-50752-00 1 Oxygen/Moisture Filter 226-50758-00 1 Make-Up Gas ECD 2 Position Base plate 226-50772-00 1 Kit Part Number 226-50781-00 Anode Purge Gas ICP-OES / ICP-MS Plasma Gas = Nebulizer Gas Supply Gas High-Flow Base plate ICP-MS High Flow Oxygen/ Moisture Filter Bundle 226-50766-00 1 ICP-MS Base plate 226-50776-00 1 ICP-OES Kit Part Number 226-50767-00

CONNECTION DIAGRAMS SHIMADZU GAS FILTRATION CATALOGUE 5 GC / FID GC/FID Solution 2 (Carrier Gas = Make-Up Gas) Carrier = Make-Up Gas Hydrogen Triple Filter 226-50710-00 1 Air GC Hydrocarbon/Moisture Filter 226-50750-00 2 3 Position Base plate 226-50773-00 1 Kit Part Number 226-50751-00 FID Supply Gas High-Flow Base plate LC High Flow Hydrocarbon Filter Bundle 226-50760-00 1 MS Particle Filter 226-50794-01 1 High Flow Base plate 226-50775-01 1 Kit Part Number 226-50720-00 Supply Gas High-Flow Base plate LC MS High Flow Moisture Filter Bundle 226-50762-00 1 Particle Filter 226-50794-01 1 High Flow Base plate 226-50775-01 1 Kit Part Number 226-50722-00 Supply Gas High-Flow Base plate LC High Flow Hydrocarbon/ Moisture Filter Bundle 226-50764-00 1 MS Particle Filter 226-50794-01 1 High Flow Base plate 226-50775-01 1 Kit Part Number 226-50724-00

6 SHIMADZU GAS FILTRATION CATALOGUE INSTALLATION KITS Catalog No. 226-50710-00 226-50712-00 (Helium) GC/MS GC/TCD Higher data accuracy and less maintenance Greater sensitivity and less maintenance GC/MS TRIPLE FILTER KIT The triple combination filter kit is ideal for purifying GC/MS carrier gas.es. It contains oxygen, moisture and hydrocarbon scrubbers in one easy to change economical cartridge Catalog No. 226-50740-00 TOC Analyzer Greater sensitivity Zero-Air generator Cleaner gas TOC CO2/MOISTURE FILTER KIT The carbon dioxide/moisture combination filter kit is ideal for TOC analysers and Zero-Air generators. It removes both carbon dioxide and moisture from gas streams.. Catalog No. 226-50767-00 ICP-MS Greater sensitivity ICP-OES Greater sensitivity ICP-MS MOISTURE/OXYGEN FILTER KIT Removes Oxygen and Moisture from gas streams. Catalog No. 226-50780-00 GC/ECD Greater sensitivity GC/ECD FILTER KIT Removes oxygen, moisture and hydrocarbons from the carrier gas and removes moisture and oxygen from the make-up and purge gas.

INSTALLATION KITS SHIMADZU GAS FILTRATION CATALOGUE 7 Catalog No. 226-50730-00 GC/FID Greater sensitivity FID 3 POSITION KIT The FID Filter kit is the perfect all-in-one solution for purifying flame ionization detector (FID) fuel gases together with the carrier gas. This kit removes hydrocarbons, moisture and oxygen from the carrier gas and removes both moisture and hydrocarbons from the Hydrogen and Air fuel gases. Catalog No. 226-50720-00 Greater sensitivity HYDROCARBON KIT Up to 20 L/min. of hydrocarbon-free nitrogen per minute with this High Flow Kit Catalog No. 226-50722-00 Greater sensitivity MOISTURE KIT Up to 20 L/min. of moisture-free nitrogen per minute with this High Flow Kit Catalog No. 226-50724-00 Greater sensitivity COMBI (HYDROCARBON/MOISTURE) KIT Removes Moisture and Hydrocarbons from high flow gas streams.

8 SHIMADZU GAS FILTRATION CATALOGUE REPLACEMENT FILTERS AND BUNDLES Catalog No. 226-50710-00 226-50752-00 (Helium) 226-50752-10 (Hydrogen) Replacement Filter for GC/MS Triple Filter Kit GC/MS TRIPLE (OXYGEN/MOISTURE/ HYDROCARBON) FILTER The Triple trap is ideal for purifying carrier gas. It contains oxygen, moisture and hydrocarbon scrubbers in one easy to change economical cartridge H 2 O 1.8 g O 2 75 ml HC 4 g (as n-butane) Catalog No. 226-50759-00 Replacement Filter for TOC CO 2 /Moisture Filter Kit TOC COMBI (CARBON DIOXIDE/ MOISTURE) FILTER Removes carbon dioxide and moisture from gas streams. H 2 O 3.5 g CO 2 6 g Catalog No. 226-50766-00 Replacement Filters for ICP-MS Moisture/Oxygen Filter Kit ICP-MS COMBI (OXYGEN/MOISTURE) FILTER BUNDLE Removes Oxygen and Moisture from the ICP-MS supply gas stream. To be used in combination with a high flow ICP-MS base plate. H 2 O 7.2 g 150 ml O 2 Catalog No. 226-50781-00 Replacement Filters for GC/ECD Filter Kit GC/ECD FILTER BUNDLE Removes oxygen, moisture and hydrocarbons from the carrier gas and removes moisture and oxygen from the make-up and purge gas. H 2 O 1.8 g / 3.5 O 2 75 ml / 75 ml HC 4 g (as n-butane)

REPLACEMENT FILTERS AND BUNDLES SHIMADZU GAS FILTRATION CATALOGUE 9 Catalog No. 226-50761-00 Replacement Filters for FID 3 Position Filter Kit FID FILTER BUNDLE OF 3 Removes Oxygen and Moisture from high flow gas streams. To be used in combination with a high flow base plate. H 2 O 7.2 g 150 ml O 2 Catalog No. 226-50760-00 Replacement Filters for Hydrocarbon Filter Kit HIGH FLOW HYDROCARBON FILTER BUNDLE Up to 20 L/min. of hydrocarbon-free nitrogen per minute. To be used in combination with a high flow base plate. HC 24 g (as n-butane) Catalog No. 226-50762-00 Replacement Filters for Moisture Filter Kit HIGH FLOW MOISTURE FIL- TER BUNDLE Removes moisture from high flow gas streams. To be used in combination with a high flow base plate. H 2 O 14.4 g Catalog No. 226-50764-00 Replacement Filters for Combi (hydrocarbon/ moisture) Filter Kit HIGH FLOW COMBI (HYDRO- CARBON/MOISTURE) FILTER BUNDLE Removes Moisture and Hydrocarbons from high flow gas streams. To be used in combination with a high flow base plate. HC 12 g (as n-butane) H 2 O 7.2 g

10 SHIMADZU GAS FILTRATION CATALOGUE INDIVIDUAL FILTERS Catalog No. 226-50754-00 Inert carrier gas, He, H2, N2, AR, Air MOISTURE FILTER Moisture in carrier gas lines will prematurely degrade oxygen and hydrocarbon traps and increase detector noise. As a precaution, we higly recommend installing a moisture trap before the hydrocarbon and oxygen traps on all carrier gas lines. H 2 O 7.2 g Catalog No. 226-50755-00 Inert carrier gas, He, H2, N2, AR OXYGEN FILTER Oxygen is a column killer. It is present even in UHP gases, as minutes leaks at fittings allow oxygen to influx against the concentration gradient. Because oxygen can enter a gas line at any fitting or during gas bottle exchange, the oxygen trap should be the last connection before the gas line enters the chromatograph. 150 ml O 2 Catalog No. 226-50756-00 Inert carrier gas, He, H2, N2, AR, Air HYDROCARBON FILTER Use a hydrocarbon trap if your gas has a potential source of hydrocarbon contaminants or if you suspect you are observing carrier gas ghost peaks. Install the hydrocarbon trap after the moisture trap, to prevent moisture from degrading the hydrocarbon-trapping ability of the activated carbon in the hydrocarbon trap. HC 12 g (as n-butane) Catalog No. 226-50757-00 Inert carrier gas, He, H2, N2, AR, Air CARBON DIOXIDE FILTER Removes carbon dioxide from gas streams. To be used in combination with a Moisture Filter CO 2 12 g

COMBINATION FILTERS SHIMADZU GAS FILTRATION CATALOGUE 11 Catalog No. 226-50750-00 Inert carrier gas, He, H2, N2, AR, Air COMBI (HYDROCARBON/ MOISTURE) FILTER The Fuel Gas Filter is perfect for purifying flame ionization detector (FID) fuel gases, removing both moisture and hydrocarbons. Using the Fuel Gas Filter for FID Hydrogen and air will produce a stable baseline, improving overall reproducability and sensitivity. H 2 O 3.5 g HC 6 g (as n-butane) Catalog No. 226-50758-00 Inert carrier gas, He, H2, N2, AR COMBI (OXYGEN/MOISTURE) FILTER This Combi trap is ideal for purifying carrier gas. It contains oxygen and moisture scrubbers in one easy to change economical cartridge H 2 O 3.5 g 75 ml O 2 Catalog No. 226-50759-00 Inert carrier gas, He, H2, N2, AR, Air COMBI (CARBON DIOXIDE/ MOISTURE) FILTER Removes carbon dioxide and moisture from gas streams. H 2 O 3.5 g CO 2 6 g Catalog No. 226-50751-00 226-50752-00 (Helium Specific) 226-50752-10 (Hydrogen Specific) Inert carrier gas, He, H2, N2, AR TRIPLE (OXYGEN/MOISTURE/ HYDROCARBON) FILTER The Triple trap is ideal for purifying carrier gas. It contains oxygen, moisture and hydrocarbon scrubbers in one easy to change economical cartridge H 2 O 1.8 g O 2 75 ml HC 4 g (as n-butane)

12 SHIMADZU GAS FILTRATION CATALOGUE BASE PLATES Catalog No. Fitting Type 226-50771-00 1/8 SS 1 POSITION BASE PLATE Single position base plate Catalog No. Fitting Type 226-50772-00 1/8 SS 2 POSITION BASE PLATE Double position base plate Catalog No. Fitting Type 226-50773-00 1/8 SS 3 POSITION BASE PLATE Three position base plate Catalog No. Fitting Type 226-50776-00 1/8 SS ICP-MS HIGH FLOW BASE PLATE High Flow Base plate for ICP-MS (in parallel) Catalog No. Fitting Type 226-50775-01 1/4 Brass 226-50775-00 1/4 SS HIGH FLOW BASE PLATE High Flow double position base plate (in parallel)

BASE PLATE ACCESORIES SHIMADZU GAS FILTRATION CATALOGUE 13 Catalog No. Clip Type 226-50798-00 Filter Cartridge 226-50797-00 Universal Ring Nut All base plates with Universal Ring Nut ELECTRONIC INDICATOR Electronic Maintenance Indicator device warns when scheduled filter replacement or base plate maintenance is due. Catalog No. 226-50799-00 All base plates Catalog No. 226-50770-00 All base plates UNIVERSAL RING NUT Universal Ring Nut to mount a filter or flush-cap on a base plate. O-RING REPLACEMENT SET O-ring replacement set for replacing the O-rings on the in- and outlet valves on a base plate. Catalog No. 226-50790-00 All base plates WALL-MOUNT BRACKET SET Wall mounting brackets to mount a Base plate on a wall. Catalog No. 226-50796-00 All base plates UNIVERSAL FLUSH-CAP SET Flush-cap that mounts on a base plate, and allows the gas to pass through the base plate without a filter attached. Catalog No. Connection Type 226-50792-01 1/4 Brass 226-50791-01 1/8 Brass 226-50792-00 1/4 SS 226-50791-00 1/8 SS 1, 2, 3 and 4 position base plates STANDARD BASE PLATE CONNECTOR SET Replacement connectors for standard base plates. Catalog No. Connection Type 226-50793-01 1/4 Brass 226-50793-00 1/4 SS High flow base plates HIGH FLOW BASE PLATE CONNECTOR SET Replacement connector for high flow base plates. Catalog No. Description 226-50794-01 0.5 Micron Particle Filter (1/4 Brass) 226-50795-00 0.5 Micron Particle Filter Cup Replacement Pack PARTICULATE FILTER Particulate filter for high flow base plates.

14 SHIMADZU GAS FILTRATION CATALOGUE CAPILLARY COLUMN CUTTERS Catalog No. 226-50700-00 Fused Silica Capillary Column Ø 0.5 Use with 0.25mm ID to 0.53mm ID tubing (0.78mm OD maximum). 9.2 cm x 1.7 cm x 1.7 cm 94 g SHORTIX TM GC In Gas chromatography, the Glass Quick-Fit connection is often used (e.g. for Retention Gaps, Guard Columns). This connection will only be leaktight when the column is cut extremely straight and without any damage to the fused-silica column wall. Catalog No. 226-50700-01 Fused Silica Capillary Column Ø 0.25micron 9.7 cm x 1.7 cm x 1.7 cm 94 g SHORTIX TM CE-CEC For CE/CEC analyses, a clean and straight cut of the capillary column is needed to assure symetrical Field- Strength over the inlet of the column. When there is no symetrical Field- Strength, the analytical results will be non-reproducible. Catalog No. 226-50700-10 Shortix TM GC MAINTENANCE KIT FOR SHORTIX TM GC Includes diamond cutting wheel, O-rings and a tool to open the column cutter. Catalog No. 226-50700-11 Shortix TM CE-CEC MAINTENANCE KIT FOR SHORTIX TM CE-CEC Includes diamond cutting wheel, O-rings and a tool to open the column cutter.

Shimadzu Corporation www.shimadzu.com