1 Autofil Bottle Top Filters Autofil is the most innovative bottle top vacuum operated laboratory filtration system in the world. The filters are used for the sterile preparation of buffers, tissue culture media, microbiological media, and other biological fluids. Fluid andling System Sterile Vacuum Filtration of Aqueous Fluids INDEX Filtration System Autofil 281 Cellulose Nitrate Membrane (ESTERS) Filters 283 Gridded Cellulose Nitrate Membrane Disc Filter 284 Cellulose Acetate Membrane Filter 284 Nylon-66 Membrane Filter 285 Nylon-66 Membrane Disc Filter 285 Nitrocellulose Membranes 286 Nylon 6,6 Blotting Membranes 287 Cellulose Acetate Syringe Filters 288 PES (Poly Ethersulfone) Syringe Filters 288 PVDF (Poly Vinylidene Fluoride) Syringe Filters 289 Nylon Syringe Filters Filtration System Autofil Benefits of using the Autofil TM filtration System 3 Vacuum hose is connected just one time 3 Pedestal offers fast connection and hands-free operation 3 Forward facing graduation marks on tubes and bottles 3 Vacuum on and off switch conveniently located 3 Autofil TM design including an ergonomic bottle shape. molded finger grips and patented bottle cap 3 Conveniently sold presterilized 3 Autofil TM is available as a complete system or as a bottles-top filter A B Protein Binding increased throughput (90mm Membrane) A Centrifuge tubes available in 15ml and 50ml B Bottles available in 250ml, 500ml and 1000ml sizes 0.22µm and 0.45µm PES membrane pore-size options available Available in 0.22µm or 0.45µm asymmetric membrane filter Easy initial setup of Autofil TM filtration System 1 Connect a vacuum tube just 2 Vacuum connects automatically 3 Once fluid is added to the top once to the back of the Autofil TM when filter is placed on the of the Autofil TM system, turn the pedestal. Autofil TM pedestal. vacuum switch on.

2 282 Autofil Filtration System Complete Assembly GX CA Autofil, Complete Assembly, PES, 15ml,.22µm, 24/Cs 12,771 GX CA Autofil, Complete Assembly, PES, 15ml,.45µm, 24/Cs 12,771 GX CA Autofil, Complete Assembly, PES, 50ml,.22µm, 24/Cs 12,771 GX CA Autofil, Complete Assembly, PES, 50ml,.45µm, 24/Cs 12,771 GX CA Autofil, Complete Assembly, PES, 250ml, 66mm,.22µm, 12/Cs 7,822 GX CA Autofil, Complete Assembly, PES, 250ml, 66mm,.45µm, 12/Cs 7,822 GX CA Autofil, Complete Assembly, PES, 500ml, 90mm,.22µm, 12/Cs 10,633 GX CA Autofil, Complete Assembly, PES, 500ml, 90mm,.45µm, 12/Cs 9,707 GX CA Autofil, Complete Assembly, PES, 1000ml, 90mm,.22µm, 12/Cs 12,182 GX CA Autofil, Complete Assembly, PES, 1000ml, 90mm,.45µm, 12/Cs 12,182 Bottle-Top Only GX BT Autofil, Bottle-Top, PES, 250ml, 66mm,.22µm, 24/Cs 11,217 GX BT Autofil, Bottle-Top, PES, 250ml, 66mm,.45µm, 24/Cs 11,217 GX BT Autofil, Bottle-Top, PES, 500ml, 90mm,.22µm, 24/Cs 12,817 Selection Guide Pore Size Best For 0.1μm 0.2μm 0.45μm 0.8μm Cell Culture (Sterilization & Mycoplasma removal) Cell Culture (Sterilization) Buffers (clarification, particle removal) Prefilteration and Clarification Membrane Attributes Best For PES Lowest protein binding, lowest Cell Culture media and serum extractables, fastest flow SFCA Lower extractables than standard Cell Culture media and serum cellulose acetate CN igher extractables Buffers Nylon igher protein binding, Alcoholic solutions alcohol resistance GX BT Autofil, Bottle-Top, PES, 500ml, 90mm,.45µm, 24/Cs 12,817 GX BT Autofil, Bottle-Top, PES, 1000ml, 90mm,.22µm, 24/Cs 20,028 GX BT Autofil, Bottle-Top, PES, 1000ml, 90mm,.45µm, 24/Cs 20,028 Pedestal Stand GX-81PDS Pedestal Stand 58,710 Bottles Only GX PS 250ml Bottle Only ( 24/Cs) 6,080 GX PS 500ml Bottle Only ( 24/Cs) 8,718 GX PS 1000ml Bottle Only ( 24/Cs) 10,697 GX PC 250ml Bottle Only ( 24/Cs) 7,776 GX PC 500ml Bottle Only ( 24/Cs) 11,735 GX PC 1000ml Bottle Only ( 24/Cs) 15,880 GX PETG 250ml Bottle Only (24/Cs) 7,304 GX PETG 500ml Bottle Only (24/Cs) 10,697 GX PETG 1000ml Bottle Only (24/Cs) 13,902 Selection Chart For Blotting Membranes This selection chart highlights the suitability of various blotting membranes for different applications based on their properties. Membrane Type SCN Pure SNN Pure Cellulose Nitrate Nylon-66 Biomolecules Nucleic Acids R R Proteins R R Transfer Method Dot Blot R R Colony or Plaque Lift R R Electrotransfer R* R Capillary Blot R R Vaccum Blot R R Alkaline Transfer NR R Molecule Fixation Baking R R Drying R R UV Crosslinking P R Alkali Fixation NR R Molecule Removal NR NR Detection Method Colorimetric R R Radiolabelled R R Luminescent R P Fluorescent R P Staining R P Reprobing Once NR R Multiple NR R R=ighlyRecommended, R=Recommended, R*=RecommendedforProteinsonly, P=Possible, NR = Not Recommended

3 Membrane Filters Cellulose Nitrate Membrane Disc Filters are hydrophilic, non-media, migrating, biologically inert, plain white absolute membrane filters available in a wide range of pore sizes. Features and Benefits 3 Absolute retention 3 igh flow rates 3 Narrow pore size distribution 3 Low extractable levels 3 Sterilisation: Autoclavable at 121 C in dry conditions 3 Maximum Operating Temperature: 80 C continuous 3 Maximum Operating Pressure: 3 Kg/cm2 3 Biosafety: Passed the Biological tests for Class VI plastics as described in USP 3 Oxidizable Matter: Passed as per USP Cellulose Nitrate Membrane (ESTERS) Filters Cellulose nitrate membranes have a very uniform pore structure and are available in a wide range of pore sizes. 283 Cellulose Nitrate Membrane Filters 0.2 um for the sterile filtration of aqueous buffer water 0.45um pore size for particle collection, filtering beverages etc. The larger pore sizes (5um, 3um) find use for chemo taxis and cell and particle retentions stidies. The high non-specific adsorption of the cellulose nitrate membrane is advantageous for diagnostic kits. The adsorption decrease with increasing pore sizes. ONO 2 C 2 ONO 2 O O ONO i. Sample Preparations, ii. Microbiological studies, iii. Filtration of aqueous solutions 2 O O O C 2 ONO 2 ONO 2 n Specifications Pore Size 0.22µm 0.45µm Diameter 13mm, 25mm, 47mm, Water Flow Rate (ml/min/cm²) at ΔP = 10psi, 20 C Retention Efficiency 0.22µm: LRV > 7 for br. diminuta Integrity Test Data Pore Size Wetting Fluid Bubble Point 0.22µm Water 52psi 3.65 kg/cm² 0.45µm Water 33psi 2.32 kg/cm² 0.8µm Water 14psi 0.98 kg/cm² Cellulose Nitrate Membrane (Ester)Filters GX22013CN Cellulose Nitrate, 0.2µm, 13mm, 100/Pk 595 GX22025CN Cellulose Nitrate, 0.2µm, 25mm, 100/Pk 675 GX22047CN Cellulose Nitrate, 0.2µm, 47mm, 100/Pk 895 GX45013CN Cellulose Nitrate, 0.45µm, 13mm, 100/Pk 595 GX45025CN Cellulose Nitrate, 0.45µm, 25mm, 100/Pk 675 GX45047CN Cellulose Nitrate, 0.45µm, 47mm, 100/Pk 895 GX12013CN Cellulose Nitrate, 1.2µm, 13mm,100/Pk 595 GX12025CN Cellulose Nitrate, 1.2µm, 25mm, 100/Pk 675 GX12047CN Cellulose Nitrate, 1.2µm, 47mm, 100/Pk, 895

4 284 Membrane Filters Cellulose Nitrate / Acetate Membrane Filters Gridded Cellulose Nitrate Membrane Disc Filters - GCN GCN membrane are made of Cellulose Nitrate, a material which assures effective retention with high flow rates. These membranes are useful for water microbiology. A grid is printed on the surface to facilitate counting of colonies. Features and Benefits 3 igh flow rates 3 Non-inhibiting ink grids 3 Validated for microbial recovery GCN membranes are useful for water microbiology. The printed grid eases the counting of bacterial colonies, micro colonies etc., and in no way influences the growth of bacteria. CN Grided Membrane Disc Filters GX22025CN-GS CN Grided, 0.2µm, 25mm, 100/Pk 1,350 GX22047CN-GS CN Grided, 0.2µm, 47mm, 100/Pk 1,620 GX45025CN-GS CN Grided, 0.45µm, 25mm, 100/Pk 1,350 GX45047CN-GS CN Grided, 0.45µm, 47mm, 100/Pk 2,696 Sterile Membrane Disc Filters GX22013CN-S Cellulose Nitrate, 0.2µm, 13mm, 100/Pk 845 GX22025CN-S Cellulose Nitrate, 0.2µm, 25mm, 100/Pk 925 GX22047CN-S Cellulose Nitrate, 0.2µm, 47mm, 100/Pk 1,075 GX45013CN-S Cellulose Nitrate, 0.45µm, 13mm, 100/Pk 845 GX45025CN-S Cellulose Nitrate, 0.45µm, 25mm, 100/Pk 925 GX45047CN-S Cellulose Nitrate, 0.45µm, 47mm, 100/Pk 1,075 GX08013CN-S Cellulose Nitrate, 0.8µm, 13mm, 100/Pk 845 GX12013CN-S Cellulose Nitrate, 1.2µm, 13mm, 100/Pk 845 GX12025CN-S Cellulose Nitrate, 1.2µm, 25mm, 100/Pk 925 GX12047CN-S Cellulose Nitrate, 1.2µm, 47mm, 100/Pk 1,075 Cellulose Acetate Membrane Filter Cellulose acetate membranes are fine pored film materials having pore sizes ranging from 0.2μm to 3μm and total porosity of 80-85%.These membranes are produced unsupported or supported as discs of various-diameters (13, 35 & 47mm). These membranes are used for filtration of microbiological, biological, physical-chemical research work & of various other samples for different applications. Sterile filtration of water, culture media, solutions containing antibiotics or proteins, cell harvesting. Features 3 Very low non-specific adsorption 3 Excellent thermal resistance 3 Validated using Brevundimonas dimimuta 3 Technical Advantages 3 Minimum loss of proteins, preservatives etc. Autoclavable at 121 C or 134 C 3 Dry heat sterilization possible; Reliable sterile filtration OCOC 3 O O O C 2 OCOC 3 C 2 OCOC 3 O O OCOC 3 Specifications n Adsorption BSA<10ug/cm 2 Bubble point for 0.2um=3.3bar, 0.45um=1.9bar Chemical compatibility Resistant to aqueous solutions, p 4-8, against most alcohols, hydrocarbons and oils Extractable with water Less than 1% Material Cellulose acetate Sterilization By autoclaving at 121 o C or 134 o C with g radiation, dry heat or ethylene oxide Sterilized filtration Filters with 0.2um pore size validated by bacteria challenge Tests. Thermal Stability MAX 180 o C Cellulose Acetate GX22013CA Cellulose Acetate, 0.2µm, 13mm, 100/Pk 1,945 GX22025CA Cellulose Acetate, 0.2µm, 25mm, 100/Pk 2,380 GX22047CA Cellulose Acetate, 0.2µm, 47mm, 100/Pk 3,455 GX45013CA Cellulose Acetate, 0.45µm, 13mm, 100/Pk 1,945 GX45025CA Cellulose Acetate, 0.45µm, 25mm, 100/Pk 2,380 GX45047CA Cellulose Acetate, 0.45µm, 47mm, 100/Pk 3,455 OCOC 3

5 285 Nylon-66 Membrane Filter - Type NN Nylon Membrane Disc Filters are double layered hydrophilic, non-media migrating, biologically inert, flexible, durable, plain white absolute membrane filters offering a wide chemical compatibility. Features and Benefits 3 Absolute retention 3 Wide Chemical Compatibility( Compatible to many solvents & alkali solutions - p Range No extractables). 3 igh heat resistance 3 ave better base of handling Specifications Pore Size 0.22µm 0.45µm Diameter 13mm, 25mm, 47mm, Water Flow Rate (ml/min/cm²) at ΔP = 10psi, 20 C Retention Efficiency 0.22µm: LRV > 7 for br. diminuta Sterilisation: Autoclavable at 121 C for 5 cycles Maximum Operating Temperature: 80 C continuous Maximum Operating Pressure: 3 Kg/cm² Biosafety: Passes the Biological tests for Class VI plastics as described in USP Extractables with Water: Within Limits as specified in USP Oxidizable Matter: Passes as per USP Integrity Test Data Pore Size Wetting Fluid Bubble Point 0.22µm Water 52psi 3.65 kg/cm² 0.45µm Water 33psi 2.32 kg/cm² Nylon-66 Membrane Disc Filter - Type NN NN Membrane Disc Filters are hydrophilic, biologically inert, non media migrating, plain white absolute membranes. Recommended for filtration, sterilisation & clarification of mobile Phase in PLC processes with aqueous, alkaline & organic samples. Features and Benefits 3 Wide Chemical Compatibility 3 Low extractables 3 PCL Certified - Assures that the filters do not add any artefacts to the sample. Membrane Filters Nylon Nylon Membrane Filters for the Filtration of Alkaline Solutions & Organic Solvents Membrane Disc Filter Type- NN GX22013NN Nylon-66, 0.2µm, 13mm, 100/Pk 675 GX22025NN Nylon-66, 0.2µm, 25mm, 100/Pk 950 GX22047NN Nylon-66, 0.2µm, 47mm, 100/Pk 1,225 GX45013NN Nylon-66, 0.45µm, 13mm, 100/Pk 675 GX45025NN Nylon-66, 0.45µm, 25mm, 100/Pk 950 GX45047NN Nylon-66, 0.45µm, 47mm, 100/Pk 1,225 Membrane Disc Filter Type - NN GX22013NN Nylon-66, 0.2µm, 13mm, 100/Pk 675 GX22025NN Nylon-66, 0.2µm, 25mm, 100/Pk 950 GX22047NN Nylon-66, 0.2µm, 47mm, 100/Pk 1,225 GX45013NN Nylon-66, 0.45µm, 13mm, 100/Pk 675 GX45025NN Nylon-66, 0.45µm, 25mm, 100/Pk 950 GX45047NN Nylon-66, 0.45µm, 47mm, 100/Pk 1,225

6 286 Nitrocellulose Membranes Transfer / Blotting Membrane Transfer/Blotting Mambranes Nitrocellulose Membranes These membranes are produced specially for life science research. They are used both for dot blot as well as gel transfer. They have a high binding capacity for proteins. These membranes are well adapted to all kinds of protein blotting systems e.g. semi dry, capillary or electro transfer. They can also be used for nucleic acids. NC membranes are available as an economical alternative for nucleic acid and protein blotting protocols. These nitrocellulose transfer membranes were the original matrices used in key Southern, colony/plaque, and protein protocols. NC contains mixed cellulose esters matrix with no surfactant to interfere with cell wall integrity during cell growth. Use these membranes for colony lifts. These are mixed cellulose esters with surfactants that improve wetability ability and handling during the transfer process. Both membranes have a high binding capacity for nucleic acids and proteins. They are suitable for routine transfers. Features and Benefits 3 igh binding capacities for proteins and nucleic acid molecules Minimum background 3 igh signal to noise ratio 3 Uniform and easy wetability 3 Can be blocked by normal blocking methods 3 Does not bind common protein stains 3 Compatible with colorimetric, radiolabelled, chemiluminescent, fluorescent and staining detection methods Protein blotting, nucleic acid dot/slot blots, colony/plaque lifts, enzyme immunoassays Specifications Type Pore Size Size SCN 0.22µm 0.45µm 82 mm circles 90 mm circles 142 mm circles 150 mm x 150 mm sheets 200 mm x 200 mm sheets 300 mm x 300 mm sheets 300mm x 3mtr. roll GX222020SCN NitroCellulose, 0.2µm, 200 x 200mm sheet, 25/Pk 12,500 GX223030SCN NitroCellulose, 0.2µm, 300 x 300mm sheet, 25/Pk 27,500 GX22082SCN NitroCellulose, 0.2µm, 82mm, 50/Pk 4,085 GX CN NitroCellulose, 0.2µm, 30cm x 3m, 1 roll 8,750 GX22090SCN NitroCellulose, 0.2µm, 90mm, 50/Pk 4,085 GX45090SCN NitroCellulose, 0.45µm, 90mm, 50/Pk 4,085 GX22142SCN NitroCellulose, 0.2µm, 142mm, 50/Pk 6,805 GX452020SCN NitroCellulose, 0.45µm, 200 x 200mm sheet, 25/Pk 12,500 GX221515SCN NitroCellulose, 0.2µm, 150 x 150mm sheet, 25/Pk 8,200 GX453030SCN NitroCellulose, 0.45µm, 300 x 300mm sheet, 25/Pk 27,500 GX CN NitroCellulose, 0.45µm, 30cm x 3m, 1 roll 8,750 Transfer Membrane Nitro Cellulose Membrane

7 287 Nylon 6,6 Blotting Membrane SNN membranes are pure Nylon-66 highly uniform membranes, specially useful for nucleic acid binding. Nylon membranes cast from nylon 6,6 polymer(1,2) have superior handling characteristics relative to nitrocellulose membranes and are better able to withstand the chemical conditions for stripping DNA or RNA probes. The use of nylon membranes in nucleic acid blotting applications has improved the performance and capabilities of hybridization-based assays.these are positively charged with 0.2um & 0.45um pore sizes. The open pore structure permits maximum accessibility of target sequences to the probe and allows efficient removal of unhybridized probes, thereby reducing background. Micro-Por range offers choice of transfer membranes for nucleic acid applications. For superior results in Southern blotting, Northern blotting, and colony/plaque lifts, positively charged Ny+ transfer membrane is recommended for Southern and colony plaque protocols, and is also available as a less sensitive and more economical alternative. Ny+positively charged nylon membrane optimized for reliable and reproducible transfer, immobilization, hybridization, and subsequent reprobing. The density and uniformity of the positively charged surface produces maximum sensitivity with minimal background. The membrane is reinforced for enhanced durability, which is especially important in reprobing experiments. Features and Benefits 3 Maximum transfer of bimolecules from the gel 3 Maximum binding and retention of the transferred biomolecules on the membrane throughout subsequent analyses 3 Maximum accessibility of all membrane-bound bimolecules to the probe 3 Maximum detection sensitivity and minimum background 3 Exceptional reprobing characteristics 3 Performs well in both chemiluminescent and radioactive detection systems Nucleic acid transfers, dots/slot blots, colony/plaque lifts and multiple reprobing Specifications Type Pore Size Size SNN 0.22µm 0.45µm 82 mm circles 90 mm circles 142 mm circles 150 mm x 150 mm sheets 200 mm x 200 mm sheets 300 mm x 300 mm sheets 300mm x 3mtr. roll Positively Charged Nylon Membrane GX22082BNN Nylon-66, 0.2µm, 82mm, 50/Pk 4,480 GX22090BNN Nylon-66, 0.2µm, 90mm, 50/Pk 4,480 GX221515BNN Nylon-66, 0.2µm, 15cm x 15cm, 25/Pk 17,550 GX222020BNN Nylon-66, 0.2µm, 20 x 20cm, 25/Pk 13,410 GX223030BNN Nylon-66, 0.2µm, 30 x 30cm, 25/Pk 29,769 GX BNN Nylon-66, 0.2µm, 82mm, 30cm x 3m, 1 Roll 10,800 GX452020BNN Nylon-66, 0.45µm, 20 x 20cm, 25/Pk 13,410 GX453030BNN Nylon-66, 0.45µm, 30 x 30cm, 25/Pk 29,769 GX BNN Nylon-66, 0.45µm, 30 x 30m, 1 Roll 10,800 Transfer/Blotting Mambranes Nylon 6,6 Blotting Membranes

8 288 Cellulose Acetate Syringe Filter PES (Poly Ethersulfone) Syringe Filters Cellilose Acetate Cellulose Acetate Syringe Filters show high flow rates and thermal stability with very low adsorption characteristics. Ideal for filtration of all kinds of biological samples for tissue culture applications, water & buffer samples, etc. Specification Retention Efficiency Wetability Sterilization Effective filtration area old up volume Extractables (NVR) Initial Water flow rate Filtration Volume 0.2 μm LRV > 7 for Brevundimonas diminuta 0.45 μm LRV > 7 for Serratia marcescens ydrophilic ETO 0.8 cm2 for 13mm & 3.9 cm2 for 25mm < 20 μl for 13 mm & < 100 μl for 25 mm (after air purge) Very low (with in limit as specified in USP XXIV) 38.4 ml/min for 0.2 μm & 72.3 ml/min for 0.45 μm (at 10 psi for 25 mm) 1-10ml for 13mm & ml for 25mm Minigen Cellulose Acetate Syringe filters, Sterile MG13020-CASL MG13045-CASL MG25020-CASL MG25045-CASL Minigen Cellulose Acetate Syringe Filters, Sterile, 0.20µm, 13mm, 1-10ml, 50/Pk 2,525 Minigen Cellulose Acetate Syringe Filters, Sterile, 0.45µm, 13mm, 1-10ml, 50/Pk 2,525 Minigen Cellulose Acetate Syringe Filters, Sterile, 0.20µm, 25mm, ml, 50/Pk 2,575 Minigen Cellulose Acetate Syringe Filters, Sterile, 0.45µm, 25mm, ml, 50/Pk 2,575 PES Syringe Filters are used for various laboratory filtration applications. These syringe filters are validated for retention efficiency, protein binding, chemical compatibility and extractables. Biological and pharmaceutical solutions can be filtered, in a wide p range of p2-12, because of their low protein adsorption shown by them. Specific Features 3 Low protein binding to minimize sample loss 3 Wide chemical compatibility 3 Low sample absorption 3 For Analytical and Research applications 3 Recommended for aqueous as well as organic solvent filtration 3 Filtration of difficult solutions Minigen Plus Syringe Filters, Sterile MG25020-CASGFL Minigen Plus Syringe Filters, Sterile, 0.2µm, 25mm, ml, 50/Pk 3,850 Minigen Cellulose Acetate Syringe filters, Non-Sterile MG13020-CABL Minigen Cellulose Acetate Syringe Filters, Non-Sterile, 00.20µm, 13mm, 1-10ml, 50/Pk 1,950 MG13045-CABL Minigen Cellulose Acetate Syringe Filters, Non-Sterile, 0.45µm, 13mm, 1-10ml, 50/Pk 1,950 MG25020-CABL Minigen Cellulose Acetate Syringe Filters, Non-Sterile, 0.20µm, 25mm, ml, 50/Pk 2,000 MG25045-CABL Minigen Cellulose Acetate Syringe Filters, Non-Sterile, 0.45µm, 25mm, ml, 50/Pk 2,000 Note : Non-Sterile, packed in transparent Plastic Jar (BULK PACK) Retention Efficiency 0.2 μm LRV > 7 for Brevundimonas diminuta 0.45 μm LRV > 7 for Serratia marcescens Wettability ydrophilic Sterilization ETO Effective filtration area 0.8 cm2 for 13mm & 3.9 cm2 for 25mm old up volume < 20 μl for 13 mm & < 100 μl for 25 mm (after air purge) Extractable (NVR) Very low (with in limit as specified in USP XXIV) Initial Water flow rate 46.2ml/min for 0.2 μm & 68.0ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume 1-10ml for 13mm & ml for 25mm Minigen PES Syringe Filters MG25022PESL Minigen PES Syringe Filters, 0.22µm, 25mm, ml, 50/Pk 3,000 MG25045PESL Minigen PES Syringe Filters, 0.45µm, 25mm, ml, 50/Pk 3,000

9 289 PVDF (Poly Vinylidene Fluoride) For fast sterile filtration, low binding, sterile syringe filters are used specifically for sterile filtration of aqueous and mild organic solvent. Supplied as individually packed and bulk packaged or bulk packed in a jar (non-sterile), surfactant-free PVDF membranes. Specifications Retention Efficiency Wettability Sterilization Effective filtration area old up volume Extractable (NVR) Initial Water flow rate Filtration Volume 0.2 μm LRV > 7 for Brevundimonas diminuta 0.45 μm LRV > 7 for Serratia marcescens ydrophilic ETO 0.8 cm2 for 13mm & 3.9 cm2 for 25mm < 20 μl for 13 mm & < 100 μl for 25 mm (after air purge) Very low (with in limit as specified in USP XXIV) 41.3ml/min for 0.2 μm & 94.3 ml/min for 0.45 μm (at 10 psi for 25 mm) 1-10ml for 13mm & ml for 25mm 3 For Analytical and Research applications 3 For aqueous as well as organic solvent filtration 3 Filtration of difficult solutions Minigen PVDF Syringe Filters, Sterile MG13020-PVDFSL Minigen PVDF Syringe Filters, Sterile, 0.20µm, 13mm, 1-10ml, 50/Pk 2,850 MG13045-PVDFSL Minigen PVDF Syringe Filters, Sterile, 0.45µm, 13mm, 1-10ml, 50/Pk 2,850 MG25020-PVDFSL Minigen PVDF Syringe Filters, Sterile, 0.20µm, 25mm, 1-10ml, 50/Pk 2,950 MG25045-PVDFSL Minigen PVDF Syringe Filters, Sterile, 0.45µm, 25mm, ml, 50/Pk 2,950 Minigen PVDF Syringe Filters, Non-Sterile MG13020-PVDFBL Minigen PVDF Syringe Filters, Non-Sterile, 0.20µm, 13mm, 1-10ml, 50/Pk 2,000 MG13045-PVDFBL Minigen PVDF Syringe Filters, Non-Sterile, 0.45µm, 13mm, 1-10ml, 50/Pk 2,000 MG25020-PVDFBL Minigen PVDF Syringe Filters, Non-Sterile, 0.20µm, 25mm, ml, 50/Pk 2,100 MG25045-PVDFBL Minigen PVDF Syringe Filters, Non-Sterile, 0.45µm, 25mm, ml, 50/Pk 2,100 Note : Non-Sterile, packed in a transparent Plastic Jar (BULK PACK) Nylon Nylon syringe filters are used in different analytical applications.ydrophilic in nature, suitable for aqueous or organic sample preparation for PLC<GC or dissolution sample analysis. With its excellent flow characteristics, very low extractable levels and mechanical stability nylon offers the best combination of physical parameters to meet stringent analytical needs. Available as sterile, individually packed or bulk packed in a jar (non-sterile), PP2 housing. 3 PLC Solvents Sample Filtration 3 Mobile phase separation 3 For aqueous as well as organic solvent filtration Retention Efficiency 0.2 μm LRV > 7 for Brevundimonas diminuta 0.45 μm LRV > 7 for Serratia marcescens Wettability ydrophilic Sterilization ETO Effective filtration area 0.1cm2 for 4mm, 0.8 cm2 for 13mm & 3.9 cm2 for 25 mm old up volume < 20 μl for 13 mm & < 100 μl for 25 mm (after air purge) Extractable (NVR) Very low (with in limit as specified in USP XXIV) Initial Water flow rate 35.4 ml/min for 0.2 μm & 67.2 ml/min for 0.45 μm (ml/min at 10 psi for 25 mm) Filtration Volume 1-10ml for 13mm & ml for 25mm Minigen NYLON Syringe Filters, Sterile MG13020-NYSL Minigen NYLON Syringe Filters, Sterile, 0.20µm, 13mm, 1-10ml, 50/Pk 2,525 MG13045-NYSL Minigen NYLON Syringe Filters, Sterile, 0.45µm, 13mm, 1-10ml, 50/Pk 2,525 MG25020-NYSL Minigen NYLON Syringe Filters, Sterile, 0.20µm, 25mm, ml, 50/Pk 2,575 MG25045-NYSL Minigen NYLON Syringe Filters, Sterile, 0.45µm, 25mm, ml, 50/Pk 2,575 Minigen NYLON Syringe Filters, Non-Sterile MG13020-NYBL Minigen NYLON Syringe Filters, Non-Sterile, 0.20µm, 13mm, 1-10ml, 50/Pk 1,950 MG13045-NYBL Minigen NYLON Syringe Filters, Non-Sterile, 0.45µm, 13mm, 1-10ml, 50/Pk 1,950 MG25020-NYBL Minigen NYLON Syringe Filters, Non-Sterile, 0.20µm, 25mm, ml, 50/Pk 2,000 MG25045-NYBL Minigen NYLON Syringe Filters, Non-Sterile, 0.45µm, 25mm, ml, 50/Pk 2,000 Syringe Filters PVDF & Nylon

10 290 Biostat A Your Professional Start to Controlled Cultivation Biostat B The Multi-Talent for Research and Process Development Biostat A is a minimum footprint and easy-to-use bioreactor fermenter designed as an entry-level model for microbial fermentation and cell culture. The Biostat B is our universal benchtop controller for stirred and rocking motion systems. l Microbial fermentation and cell culture l Academic education and technical training l Early-stage research and development l Microbial, insect and mammalian cell culture l Suspension and microcarrier cultivation l Process development l Process optimization l Process characterization With its compact design, Biostat A saves valuable space in your laboratory. If you are looking for a bioreactor for training purposes or for scale-up from shake flask to controlled cell growth, Biostat A is the perfect fit. Biostat A is available in configurations for microbial fermentation and for cell culture applications. Using the advanced package, you can operate it by a tablet or a smartphone and can perform fed-batch processes. With multiple thousand installations worldwide, the Biostat B is the market leading benchtop system for various R&D applications. One Biostat B control tower controls up to two culture vessels completely independently, saving valuable bench space. It is available with the UniVessel Glass in a range of 1 L, 2 L, 5 L and 10 L, as well as with the 2 L single-use UniVessel SU and with the RM Rocker in a choice of 20 L and 50 L.

11 291 Biostat Cplus The Stainless Steel Fermenter & Bioreactor for Your Laboratory Biostat D-DCU Your Fast Lane to Production Biostat Cplus is a fermenter bioreactor developed for the fermentation of microorganisms and cultivation of animal cells. Biostat D-DCU incorporates many advanced features and preferred options to meet virtually any requirements for leading-edge bioprocess applications. l Microbial and cell culture l Suspension and microcarrier cultures l Process development and scale-up l Seed production l Protein supply for research and development l Microbial and cell culture l Suspension and microcarrier cultures l Process development and scale-up l Seed production l Production The system can be flexibly integrated into an existing laboratory infrastructure. The culture vessel can be sterilized by electro or steam heating. The casters under the supply unit of the bioreactor enable it to be easily moved to another location. The Biostat Cplus is a floor standing version, available with a selection of culture vessels with working volumes of 10 L, 15 L, 20 L and 30 L. A benchtop version is available with a 5 L working volume culture vessel. Extended functionality and ease of use is provided by a wide choice of in-line sensors and anaylzers with an integrated display of process values on the DCU screen. It is designed to interface single-use storage bags for media addition and harvesting, as well as the TAKEONE single-use aseptic sampling systems. Further enhanced functionality and ease of use are provided by a wide selection of in-line sensors and analyzers and by integrated display of process values on the DCU screen. Due to the bioreactor s modular design, various configurations are available from basic to fully featured. The system offers an excellent solution for any budget and every need. Working volumes are available in a choice of 10 L, 20 L, 30 L, 50 L, 100 L and 200 L.

12 292 Product Description Price( ) CAT# Product Description Price( ) Integra Liquid andling System CAT# The peristaltic pump DOSE IT makes dispensing of culture media, buffers and other solutions easy and ef cient. Forget about complicated programming. Choose a mode, a preprogrammed protocol or simply combine the 7 different step types, edit their parameters according to your needs and store them as a customized protocol in one of the 20 available program slots. Website:

mdi Filters for Pharmaceutical and Biological

mdi Filters for Pharmaceutical and Biological mdi Filters for Pharmaceutical and Biological Applications mdi Filters for Biologicals are specially designed filtration devices for filtration of culture media, culture soups, serum solutions, nutrients,

More information

Why filter your samples before analysis? Benefits of Using Chromfilter Syringe Filters Daily: Designed for your application:

Why filter your samples before analysis? Benefits of Using Chromfilter Syringe Filters Daily: Designed for your application: Why filter your samples before analysis? Prefiltering your sample and mobile phase solutions for particulates and microbial growth prior to analysis is critical to preventing column and frit blockage,

More information

MicroFunnel Filter Funnels

MicroFunnel Filter Funnels MicroFunnel Filter Funnels Description Increase laboratory efficiency with a newly designed, disposable filter funnel and Petri dish all in one. Certified. Each lot is certified for microbiological analysis

More information

Process Filtration From Pure to Sterile

Process Filtration From Pure to Sterile From Pure to Sterile MAIN FEATURES & BENEFITS: Excellent material resistance towards all aggressive media Inherently hydrophobic PTFE membrane Absolute rating at 0,2 µm (HIMA/ASTM) High flow rates Biologically

More information

Process Filtration From Pure to Sterile

Process Filtration From Pure to Sterile From Pure to Sterile MAIN FEATURES & BENEFITS: Extremely durable polypropylene construction Absolute rating at 0,2 µm (HIMA/ASTM) High flow rates Biologically inert Approved for Food Contact Use acc. to

More information

Polysep II Filters. Superior filters provide multiple filtration stages in a single compact configuration for critical prefiltration applications

Polysep II Filters. Superior filters provide multiple filtration stages in a single compact configuration for critical prefiltration applications Data Sheet Data Sheet Polysep II Filters Superior filters provide multiple filtration stages in a single compact configuration for critical prefiltration applications Polysep II filters are ideal for a

More information

porablot nitrocellulose membranes

porablot nitrocellulose membranes Table of Contents 1. Introduction 2 2. Southern (DNA) and Northern (RNA) Hybridizations 2 2.1 Gel Preparation 2 2.2 Membrane Preparation 2 2.3 Capillary Transfer 2 2.4 Alternative Transfer Systems 3 2.5

More information

Minisart Syringe Filters. turning science into solutions

Minisart Syringe Filters. turning science into solutions Minisart Syringe Filters turning science into solutions Table of Contents Sterile Filtration page 7 Removal of microorganisms and particles from liquids with hydrophilic Minisarts, pore sizes < 0.2 μm

More information

Cell Culture Flasks DATA SHEET

Cell Culture Flasks DATA SHEET DATA SHEET Cell Culture Flasks In research cell culture flasks are used as a matter of routine for the cultivation of eukaryotic cells. They are optimal products for adherent cells as well as for suspension

More information

Validation of Sterilizing Grade Filters

Validation of Sterilizing Grade Filters Validation of Sterilizing Grade Filters Presented by Laura Okhio-Seaman Sartorius Corporation 1 Sterilizing Grade Filters The definition of a sterilizing grade filter is one that will produce a sterile

More information

Positively Charged Membrane

Positively Charged Membrane BIOBOND NYLON MEMBRANES ProductInformation Technical Bulletin No. MB-570 June 1999 Size Quantity Positively Charged Membrane Neutral Membrane 30 cm x 3.5 m 1 roll N4781 N1031 30 cm x 12 m 1 roll N4906

More information

Plastic Storage Bottles Product Selection Guide

Plastic Storage Bottles Product Selection Guide Plastic Product Selection Guide A Wide Selection of Bottle Shapes, Sizes, and Materials for All Your Laboratory Needs Corning s disposable bottles are designed for safe, secure storage of tissue culture

More information

Filtration in Preparation of Cell Culture Media and Buffers

Filtration in Preparation of Cell Culture Media and Buffers Filtration in Preparation of Cell Culture Media and Buffers Cell Culture Media and Buffers in Biopharmaceutical Production Cell culture media and process buffers are used in all biopharmaceutical operations.

More information

Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges

Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges Validation Guide USTR 2114 (2) Validation Guide for Pall Emflon PFR Filter Cartridges CONTENTS Part I. Overview 4 1. Introduction 4 2. Summary of Conclusions 4 Part II. Studies on Removal Efficiency 6

More information

Filtration of Cell Culture Growth Media and Process Buffers

Filtration of Cell Culture Growth Media and Process Buffers Customer Application Brief Bioprocess, Biologicals, & Pharmaceutical Filtration of Cell Culture Growth Media and Process Buffers Introduction Media feeds and process buffers are two universal additives

More information

Your Guide to Upstream Processing Solutions From Research to Production

Your Guide to Upstream Processing Solutions From Research to Production Your Guide to Upstream Processing Solutions From Research to Production Upstream Process Overview Our Solutions for Your Upstream Processing Needs Sartorius offers a wide range of process solutions for

More information

Sartorius Biotechnology Filter Cartridges

Sartorius Biotechnology Filter Cartridges Sartorius Biotechnology Filter Cartridges Sartorius filter products designed for the pharmaceutical industry At Sartorius, we don t just sell you a filter. You work with experienced Sartorius filtration

More information

mdi AseptiVent VF- Gamma Irradiatable PVDF Capsule Filters Data Sheet for Sterile Filtration of Air/Gases in Biopharmaceuticals Membrane Technologies

mdi AseptiVent VF- Gamma Irradiatable PVDF Capsule Filters Data Sheet for Sterile Filtration of Air/Gases in Biopharmaceuticals Membrane Technologies DV1875C-178 AseptiVent VF-γ LVL5501EERT101 LVL 0.2µm LV 8855K - 220 Membrane Technologies AseptiVent VF-γ LVL5401EERT101 LVL 0.2µm LV 8885H - 478 DVL5701EERT101 DV1876C- 078 DVL5301EDRT101 DV2355L- 078

More information

Table of Contents. Pipette Tips. Table of Contents

Table of Contents. Pipette Tips. Table of Contents Table of Contents 53 Table of Contents 54 56 Optifit Tips 57 SafetySpace Filter Tips 58 Low Retention Tips 60 Packaging Options 54 Optifit Tips and SafetySpace Filter Tips The Perfect Match for Your Pipette

More information

Simplifying Sample Prep for Research Laboratories

Simplifying Sample Prep for Research Laboratories Simplifying Sample Prep for Research Laboratories Products for molecular purification and characterization, media prep, analytical chemistry and microbiology Simplifying Sample Prep Pall Laboratories develops

More information

Microfil Filtration System

Microfil Filtration System Data Sheet Microfil Filtration System An easy to use, fast and accurate system for the routine microbiological analysis of your beverages and drinking water The Microfil filtration system is a simple and

More information

Optiblot ECL Ultra Detect Kit (1.2pg 2ng)

Optiblot ECL Ultra Detect Kit (1.2pg 2ng) ab133409 Optiblot ECL Ultra Detect Kit (1.2pg 2ng) Instructions for Use For enhanced chemiluminescent Western blotting. This product is for research use only and is not intended for diagnostic use. 1 Table

More information

SINTERED WIRE MESH.

SINTERED WIRE MESH. SINTERED WIRE MESH www.sinteredfilter.org "Total filtration solution provider" For over 15 years, Boegger has been providing filtration solutions to a wide range of filtering industries where air, liquid

More information

DK7895C-125 DKSX5101AAXX101 DK7786D- 477

DK7895C-125 DKSX5101AAXX101 DK7786D- 477 DK7895C-125 AseptiCap KS LKSX5501EEXX101 LKS 0.2µm LK 1476B - 124 Membrane Technologies LKSX5401EEXX101 LKS 0.2µm LK 7895A - 789 AseptiCap KS DKSX5701EEXX101 DK1146C- 147 DKSX5301EDXX101 DK4555B- 147 DKSX5101JJXX101

More information

PDA Technical Report #26:

PDA Technical Report #26: PDA Technical Report #26: Implications on Liquid Filter Validation Maik W. Jornitz, Sartorius Corp. Filter Qualification Tests for internal Validation Guides Physical Tests flow rates/delta p throughput

More information

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum Microbiological Methods IX-B- 1 PRESUMPTIVE MEMBRANE FILTER METHOD AND CONFIRMATION OF PSEUDOMONAS AERUGINOSA PRINCIPLE SCOPE Presumptive Pseudomonas bacteria are quantitated by a membrane filter technique,

More information

Mini filter cartridges and capsules for the biopharmaceutical industry

Mini filter cartridges and capsules for the biopharmaceutical industry Mini filter cartridges and capsules for the biopharmaceutical industry Sartorius filter products designed for the pharmaceutical industry At Sartorius, we don t just sell you a filter. You work with experienced

More information

LumiPico ECL Kit. ShineGene. User Manual. For Western Blot. Cat.Nos.ZK00901(12.5ml 2) ZK00902(50.0ml 2) LumiPico ECL Kits User Manual

LumiPico ECL Kit. ShineGene. User Manual. For Western Blot. Cat.Nos.ZK00901(12.5ml 2) ZK00902(50.0ml 2) LumiPico ECL Kits User Manual LumiPico ECL Kits User Manual ShineGene LumiPico ECL Kit For Western Blot User Manual Cat.Nos.ZK00901(12.5ml 2) ZK00902(50.0ml 2) USD44.46 USD175.20 Published 24 Feb 2007 ShineGene LumiPico ECL Kits User

More information

Adsorptive and Mechanical Mechanisms of Fluid Purification Using Charge Modified Depth Filtration Media. Dr. Robert Conway, Ph.D.

Adsorptive and Mechanical Mechanisms of Fluid Purification Using Charge Modified Depth Filtration Media. Dr. Robert Conway, Ph.D. Adsorptive and Mechanical Mechanisms of Fluid Purification Using Charge Modified Depth Filtration Media Dr. Robert Conway, Ph.D. Depth Filter Cartridge Construction Zeta Plus Media Materials of Construction

More information

Flexsafe 3D Pre-Designed Solutions for Storage and Shipping Take Your Facility Into The Future

Flexsafe 3D Pre-Designed Solutions for Storage and Shipping Take Your Facility Into The Future Flexsafe 3D Pre-Designed Solutions for Storage and Shipping Take Your Facility Into The Future 2 Flexsafe 3D Pre-designed Solutions Table Please click on headline to go to the selected page Digital Selection

More information

Syringe Filters. Performance and Protection

Syringe Filters. Performance and Protection Syringe Filters Performance and Protection A Product You Can Trust Benefits of Using Phenex Syringe Filters Daily: Less system down time Consistent, reproducible results Increased column lifetime Quality

More information

CASY Model TT E L E C T R I C A L C U R R E N T EXCLUSION ECE BASED CELL ANALYSIS

CASY Model TT E L E C T R I C A L C U R R E N T EXCLUSION ECE BASED CELL ANALYSIS CASY Model TT Cell Counter + AnalyZer E L E C T R I C A L C U R R E N T EXCLUSION ECE BASED CELL ANALYSIS ELECTRICAL CURRENT EXCLUSION CASY Model TT Cell Counter + Analyzer R&D Easy and fast adaptation

More information

KPL SignaLOCK ChemiWestern Kits (Film and Imager Analysis)

KPL SignaLOCK ChemiWestern Kits (Film and Imager Analysis) KPL SignaLOCK ChemiWestern Kits (Film and Imager Analysis) SignaLOCK HRP ChemiWestern Kit (Film) Catalog No. 54-53-00 SignaLOCK HRP ChemiWestern Kit (Imager) Catalog No. 54-54-00 SignaLOCK AP ChemiWestern

More information

EXTRACTME Kits, Product Brochure

EXTRACTME Kits, Product Brochure EXTRACTME Kits, Product Brochure Interest in any of the products, request or order them at Bio-Connect. Bio-Connect B.V. T NL +31 (0)26 326 44 50 T BE +32 (0)2 503 03 48 Begonialaan 3a F NL +31 (0)26 326

More information

arium mini Ultrapure Water System

arium mini Ultrapure Water System arium mini Ultrapure Water System Unique bagtank technology for the Highest Efficiency Advantages Reliable: Delivers consistently high water quality for reliable and reproducible results Efficient: Avoids

More information

Development of next-generation single-use films for optimal performance in biomanufacturing

Development of next-generation single-use films for optimal performance in biomanufacturing Development of next-generation single-use films for optimal performance in biomanufacturing Susan Burke, PhD Bioprocess R&D GE Healthcare, Life Sciences Overview Importance of voice of customer in film

More information

Cells and cell cultivation

Cells and cell cultivation Cells and cell cultivation Exclusive and variable for small volumes and applications in biotechnology, medical enginnering, pharmaceutical and food Industries medorex e.k. Industriestr. 2 Tor 1 Phone:

More information

Protocol for Small-Scale Microcarrier Culture

Protocol for Small-Scale Microcarrier Culture Protocol for Small-Scale Microcarrier Culture Hillex II Microcarriers This document provides a general protocol for initiation of small-scale mammalian cell spinner cultures. This procedure is based upon

More information

Novel Advanced Polyethylene Membrane Structures

Novel Advanced Polyethylene Membrane Structures specialty engineered products and materials Novel Advanced Polyethylene Membrane Structures Magda Avramescu, John op den Kamp & Danny Hendricks THIS DOCUMENT, OR AN EMBODIMENT OF IT IN ANY MEDIA, DISCLOSES

More information

Ready to Use Disposable 96-Sample Equilibrium Dialysis Plates

Ready to Use Disposable 96-Sample Equilibrium Dialysis Plates Ready to Use Disposable 96-Sample Equilibrium Dialysis Plates Ideal for the analysis of free or unbound analytes like free T4, free Cortisol, free Testosterone, or for Protein-Ligand Binding Studies. 96-Well

More information

JM BioConnect - Make the Connection

JM BioConnect - Make the Connection JM BioConnect - Make the Connection JM BioConnect s mission statement is to be the upstream and downstream disposable process solution specialist based on open architecture. This is not limited to single

More information

Extraction Products Separator Paper 188 Solid Phase Extraction (SPE) 189 Extraction Thimbles 192. Extraction Products

Extraction Products Separator Paper 188 Solid Phase Extraction (SPE) 189 Extraction Thimbles 192. Extraction Products Separator Paper 188 Solid Phase Extraction (SPE) 189 192 : Used to determine the oil and fat content in food, an indispensable tool for food manufacturers and health practitioners. Also used to test for

More information

Reference Guide. Thermo Scientific Solutions. Automated Liquid Handling, Detection and Sample Purification

Reference Guide. Thermo Scientific Solutions. Automated Liquid Handling, Detection and Sample Purification Reference Guide Thermo Scientific Solutions Automated Liquid Handling, Detection and Sample Purification Reference Guide Thermo Scientific Solutions Automated Liquid Handling, Detection and Sample Purification

More information

Amazon FILTRATION SOLUTIONS PHARMACEUTICAL MANUFACTURING

Amazon FILTRATION SOLUTIONS PHARMACEUTICAL MANUFACTURING Amazon FILTRATION SOLUTIONS PHARMACEUTICAL MANUFACTURING FILTRATION SOLUTIONS FOR PHARMACEUTICAL MANUFACTURING Delivering quality filtration products As one of Europe s leading manufacturers of process

More information

Radiance. Long Protocol for Catalog Numbers. Chemiluminescent substrate for quantitative chemiluminescent Westerns

Radiance. Long Protocol for Catalog Numbers. Chemiluminescent substrate for quantitative chemiluminescent Westerns Radiance Chemiluminescent substrate for quantitative chemiluminescent Westerns Long Protocol for Catalog Numbers AC2100 Radiance Sample, sufficient for 140 cm 2 membrane AC2101 Radiance, 150 ml, sufficient

More information

E.Z.N.A. Bacterial RNA Kit. R preps R preps

E.Z.N.A. Bacterial RNA Kit. R preps R preps E.Z.N.A. Bacterial RNA Kit R6950-00 5 preps R6950-01 50 preps July 2017 E.Z.N.A. Bacterial RNA Kit Table of Contents Introduction and Overview...2 Kit Contents/Storage and Stability...3 Before Beginning...4

More information

E.Z.N.A. MicroElute Genomic DNA Kit. D preps D preps D preps

E.Z.N.A. MicroElute Genomic DNA Kit. D preps D preps D preps E.Z.N.A. MicroElute Genomic DNA Kit D3096-00 5 preps D3096-01 50 preps D3096-02 200 preps December 2013 E.Z.N.A. MicroElute Genomic DNA Kit Table of Contents Introduction...2 Kit Contents/Storage and Stability...3

More information

THE DISSOLUTION PROCEDURE: DEVELOPMENT AND VALIDATION

THE DISSOLUTION PROCEDURE: DEVELOPMENT AND VALIDATION THE DISSOLUTION PROCEDURE: DEVELOPMENT AND VALIDATION Pharmacopeial Forum Vol. 31(5)(Sept.-Oct. 2005) By : Mr. Seubpong Kumpusiri Mrs. Patima Maneesatid 26 May 2006 THE DISSOLUTION PROCEDURE: DEVELOPMENT

More information

F2 15/30 SIP PILOT SCALE BIOREACTORS

F2 15/30 SIP PILOT SCALE BIOREACTORS F2 15/30 SIP PILOT SCALE BIOREACTORS THE COMPANY Bionet is a specialist in bioprocesses engineering. We provide equipment (Bioreactors, Cross-Flow Filtration Systems and Cleaning-In-Place Systems) and

More information

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS FILTRATION SOLUTIONS Pharmaceutical Manufacturing filtration specialists Delivering quality filtration products As one of Europe s leading manufacturers of process filters, Amazon Filters is able to offer

More information

Annex A2. Guidance on Process Validation Scheme for Aseptically Processed Products

Annex A2. Guidance on Process Validation Scheme for Aseptically Processed Products Annex A2 Guidance on Process Validation Scheme for Aseptically Processed Products 1 Table of content 1 PURPOSE... 3 2 SCOPE... 3 3 GENERAL INFORMATION... 3 4 INFORMATION NEEDED FOR ASEPTIC PROCESSES VALIDATION...

More information

WesternBright Quantum

WesternBright Quantum User Manual WesternBright Quantum Chemiluminescent HRP Substrate For Catalog Numbers K-12042-C20 20 ml, sufficient for 200 cm 2 K-12042-D10 100 ml, sufficient for 1000 cm 2 K-12042-D20 200 ml, sufficient

More information

3M Emphaze. AEX Hybrid Purifier. 3M Innovation. Transform and Redefi ne. Effi ciency. Purity. Economics. 3M Purification

3M Emphaze. AEX Hybrid Purifier. 3M Innovation. Transform and Redefi ne. Effi ciency. Purity. Economics. 3M Purification 3M Purification SingleUse Hybrid Clarifier for Biopharmaceutical Processes 3M Emphaze AEX Hybrid Purifier 3M Innovation. Transform and Redefi ne. Effi ciency. Purity. Economics. 3M Emphaze AEX Hybrid Purifi

More information

BCH 462. Western Blot

BCH 462. Western Blot BCH 462 Western Blot Blotting Immunoassay: A test that uses antibody and antigen complexes [immuno-complexes] as a means of generating measurable results. Antigens [Ag]: A substance that when introduced

More information

EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration

EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Ready-to-use sterilized filtration devices for

More information

Your Filtration Partner. Whatman Capsule Filtration Products

Your Filtration Partner. Whatman Capsule Filtration Products Your Filtration Partner Whatman Capsule Filtration Products Product Selection Chart CAPSULES About Whatman Capsule Products Whether you are conducting research, pilot manufacturing or full-scale production,

More information

E.Z.N.A. Cycle Pure Kit

E.Z.N.A. Cycle Pure Kit E.Z.N.A. Cycle Pure Kit D6492-00 5 preps V-spin D6492-01 50 preps V-spin D6492-02 200 preps V-spin D6493-00 5 preps Q-spin D6493-01 50 preps Q-spin D6493-02 200 preps Q-spin March 2017 E.Z.N.A. Cycle Pure

More information

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Membrane Filtration Technology: Meeting Today s Water Treatment Challenges Growing global demand for clean water and increasing environmental concerns make membrane filtration the technology of choice

More information

MicroVantage MAN Series

MicroVantage MAN Series MicroVantage MAN Series Nylon 66 Membrane Filter Cartridges Absolute retention ratings from. to.65 microns Nylon 66 membranes provide electropositive charge to enhance particle removal through electrokinetic

More information

Hoefer SUBHT High Throughput Submarine Gel Electrophoresis Unit. Training Presentation

Hoefer SUBHT High Throughput Submarine Gel Electrophoresis Unit. Training Presentation Hoefer SUBHT High Throughput Submarine Gel Electrophoresis Unit Training Presentation - 2011 Agenda Product Description Customer Pain SUBHT Solution Customers Who How -? s and sample script Beating the

More information

Single-Use Simplicity

Single-Use Simplicity Single-Use Simplicity BioBLU c and BioBLU p Single-Use Vessels for cell culture »Proven stirred-tank design meets single-use technology.«reliable performance and ease-of-use Combine the benefits of single-use

More information

Advancements on implementation of single use technology in vaccine manufacturing

Advancements on implementation of single use technology in vaccine manufacturing Advancements on implementation of single use technology in vaccine manufacturing October 25 th, 2013 DCVMN Meeting Rio de Janeiro, Brazil Outline Overview of single use products Applications of single

More information

qpcr Kit, DNA-free Product components 100 rxn 250 rxn Product description

qpcr Kit, DNA-free Product components 100 rxn 250 rxn Product description qpcr Kit, DNA-free For the PCR detection and identification of bacterial and fungal DNA using custom primers Product code A8514 Product components 100 rxn 250 rxn A 2.5x mastermix (3 mm MgCl 2 final concentration)

More information

Biotin 3' End DNA Labeling Kit

Biotin 3' End DNA Labeling Kit INSTRUCTIONS Biotin 3' End DNA Labeling Kit 3747 N. Meridian Road P.O. Box 117 Rockford, IL 61105 89818 1290.4 Number Description 89818 Biotin 3' End DNA Labeling Kit, sufficient reagents to perform 20

More information

Note: for laboratory research use only. RNA High-purity Total RNA Rapid Extraction Kit (Spin-column) Signalway Biotechnology

Note: for laboratory research use only. RNA High-purity Total RNA Rapid Extraction Kit (Spin-column) Signalway Biotechnology Note: for laboratory research use only RNA High-purity Total RNA Rapid Extraction Kit (Spin-column) Cat. #: RP1202 (50preps) Signalway Biotechnology I. Kit Content, Storage Condition and Stability Content

More information

Transwell Permeable Supports Including Snapwell and Netwell Inserts Instructions for Use

Transwell Permeable Supports Including Snapwell and Netwell Inserts Instructions for Use Transwell Permeable Supports Including Snapwell and Netwell Inserts Instructions for Use Life Sciences TABLE OF CONTENTS Introduction..................................... 1 Transwell Insert Product Descriptions...............

More information

Sterilizing Grade Filters USD 2461

Sterilizing Grade Filters USD 2461 Pall Supor EKV Sterilizing Grade Filters USD 6 Supor EKV Sterilizing Grade Filters Pall Supor EKV filters are validated sterilizing grade membranes for the most cost effective filtration of a wide range

More information

E.Z.N.A. Water DNA Kit. D preps D preps D preps

E.Z.N.A. Water DNA Kit. D preps D preps D preps E.Z.N.A. Water DNA Kit D5525-00 5 preps D5525-01 50 preps D5525-02 200 preps April 2017 E.Z.N.A. Water DNA Kit Table of Contents Introduction and Overview...2 Kit Contents/Storage and Stability...3 Preparing

More information

PREFILTERS/DEPTH TYPE M EDIA

PREFILTERS/DEPTH TYPE M EDIA PREFILTERS/DEPTH TYPE M EDIA Prefilters/Depth Type Media Cellulose Fiber Filters Glass Fiber Filters Quartz Fiber Filters Specifications: Glass/Quartz Fiber Polyflon PTFE Fiber Filters Dacron Mesh Separators

More information

The Opta SFT-D is available as individual device for end-user assembly with TPE tubing and autoclave sterilization.

The Opta SFT-D is available as individual device for end-user assembly with TPE tubing and autoclave sterilization. Fluid Management 259 Connections 260 Flexboy Bags 264 Flexel 3D Bags 276 Palletank 304 Instruments 314 Single-Use Mixing 318 Freeze-Thaw Systems 354 Aseptic Transfer System 380 Configurable Solutions FlexAct

More information

ProSignal Pico Juniper Creek Lane, San Diego, CA Phone: Fax:

ProSignal Pico Juniper Creek Lane, San Diego, CA Phone: Fax: ProSignal Pico 8430 Juniper Creek Lane, San Diego, CA 92126 Phone: 800.789.5550 Fax: 888.789.0444 Email: support@geneseesci.com www.geneseesci.com User Manual ProSignal Pico Chemiluminescent HRP Substrate

More information

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions LAMBDA 265 / 365 / 465 UV/Vis Solutions MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE 2 PUTTING OUR FOCUS ON THE NEEDS OF INDUSTRY AND ACADEMIA Based on our long history of UV/Vis leadership, our LAMBDA

More information

Analytical and formulation attributes

Analytical and formulation attributes Peer reviewed article Analytical and formulation attributes in developing generic sterile injectable liquid and lyophilized drugs (part 1) Arindam Roy ARINDAM ROY 1,2 *, GURMUKH CHANANA 1 *Corresponding

More information

1 ml gel corresponds to ml of 75% (v/v) Glutathione Agarose suspension.

1 ml gel corresponds to ml of 75% (v/v) Glutathione Agarose suspension. 1 AFFINITY GST PURIFICATION Procedure for Use Glutathione Agarose 4 Resin DESCRIPTION Glutathione Agarose Resin is used to purify recombinant derivatives of glutathione S-transferases or glutathione binding

More information

FS 1000/3000 SIP BIOREACTORS/FERMENTORS FOR INDUSTRIAL PROCESSES

FS 1000/3000 SIP BIOREACTORS/FERMENTORS FOR INDUSTRIAL PROCESSES FS 1000/3000 SIP BIOREACTORS/FERMENTORS FOR INDUSTRIAL PROCESSES THE COMPANY Bionet is a specialist in bioprocesses engineering. We provide equipment (Bioreactors, Cross-Flow Filtration Systems and Cleaning-In-Place

More information

Flexboy 2D Pre-designed Solutions for Storage Best Performance, Assurance of Supply and Closure Integrity for All Process Steps

Flexboy 2D Pre-designed Solutions for Storage Best Performance, Assurance of Supply and Closure Integrity for All Process Steps Storage Best Performance, Assurance of Supply and Closure Integrity for All Process Steps 2 Flexboy 2D Pre-designed Solutions Table Please click on the headline to go to the selected topic Digital Selection

More information

High Quality Pipette Tips for Consistent and Reliable Results

High Quality Pipette Tips for Consistent and Reliable Results High Quality Pipette Tips for Consistent and Reliable Results Excellence in Quality and Convenience Sartorius pipette tips meet the highest quality and purity standards. Sartorius tips are designed and

More information

Nitor Cross-Flow Filtration Systems Designed specifically for wine

Nitor Cross-Flow Filtration Systems Designed specifically for wine Nitor Cross-Flow Filtration Systems Designed specifically for wine Nitor Cross-Flow filtration systems The Padovan NITOR Cross-Flow Filtration System was developed in 1989 as an answer to the growing issues

More information

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , , Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual Catalog Numbers 732-0026, 732-0027 732-0066, 732-0067 Table of Contents Section 1 Introduction... 1 Section 2 Connection to Bio-Rad

More information

Membranes for Transfer and Immobilization BioTrace, Biodyne, FluoroTrans and UltraBind Membranes

Membranes for Transfer and Immobilization BioTrace, Biodyne, FluoroTrans and UltraBind Membranes Product Data s for Transfer and Immobilization BioTrace, Biodyne, FluoroTrans and UltraBind s A variety of membrane chemistries for sensitive detection and consistent results in all applications and detection

More information

ab Optiblot Fluorescent Western Blot Kit

ab Optiblot Fluorescent Western Blot Kit ab133410 Optiblot Fluorescent Western Blot Kit Instructions for Use For quantitative, multi-color fluorescent Western blotting. This product is for research use only and is not intended for diagnostic

More information

ProductInformation TECHNICAL BULLETIN

ProductInformation TECHNICAL BULLETIN RapidBlot Senior Transfer System RapidBlot Junior Transfer System RapidBlot Membrane Packs with BioBond or BioBond Plus Membranes Product Codes RAPID-1, RAPID-2, RP-1, RP-2, RP-3, RP-4 Technical Bulletin

More information

Flexsafe 2D & 3D Pre-Designed Solutions for Storage and Shipping Take Your Facility Into The Future

Flexsafe 2D & 3D Pre-Designed Solutions for Storage and Shipping Take Your Facility Into The Future & 3D Pre-Designed Solutions for Storage and Shipping Take Your Facility Into The Future 2 & 3D Pre-designed Solutions Table of Contents Please click on headline to go to the selected page Back Go to to

More information

Presto Mini gdna Bacteria Kit

Presto Mini gdna Bacteria Kit Instruction Manual Ver. 02.10.17 For Research Use Only Presto Mini gdna Bacteria Kit Advantages GBB004 (4 Preparation Sample Kit) GBB100/101 (100 Preparation Kit) GBB300/301 (300 Preparation Kit) Sample:

More information

Sample Quantitation. Spectrophotometry 18. Protein Assays 20. Ordering Information 23

Sample Quantitation. Spectrophotometry 18. Protein Assays 20. Ordering Information 23 Sample Quantitation Spectrophotometry 18 Protein Assays 20 Ordering Information 23 Spectrophotometry www.bio-rad.com/spectrophotometry Spectrophotometry SmartSpec Plus Spectrophotometer Order Info: Pg

More information

Azure Biosystems Western Blotting Workflow

Azure Biosystems Western Blotting Workflow Azure Biosystems Western Blotting Workflow PROBE PLAN SEPARATE ANALYZE VISUALIZE PLAN Plan your experiment and choose your detection method Chemiluminescent Western Blotting The most common method for

More information

3.1.1 Introduction WESTERN BLOTTING. 3.1 Section

3.1.1 Introduction WESTERN BLOTTING. 3.1 Section WESTERN BLOTTING 3.1 Section 3.1.1 3.1.1 Introduction s have been standard tools in molecular biology laboratories since the 1970s, when it was discovered that biomolecules could be spotted directly onto

More information

Product Permission Document (PPD) of Botulinum Toxin Type A for Injection Ph.Eur Purified Neurotoxin Complex

Product Permission Document (PPD) of Botulinum Toxin Type A for Injection Ph.Eur Purified Neurotoxin Complex Product Permission Document (PPD) of Botulinum Toxin Type A for Injection Ph.Eur Purified Neurotoxin Complex Brand Name : BOTO GENIE 1. Introduction : BOTO GENIE (Botulinum Toxin Type A for Injection Ph.Eur)

More information

GETINGE ISOFLEX MULTI-PURPOSE ISOLATOR

GETINGE ISOFLEX MULTI-PURPOSE ISOLATOR GETINGE ISOFLEX MULTI-PURPOSE ISOLATOR 2 GETINGE ISOFLEX THE ANSWER TO YOUR DAILY NEEDS FOR STERILE HANDLING In any sterile operation, maintaining the sterility of goods -- whether you have purchased them

More information

Lecture Four. Molecular Approaches I: Nucleic Acids

Lecture Four. Molecular Approaches I: Nucleic Acids Lecture Four. Molecular Approaches I: Nucleic Acids I. Recombinant DNA and Gene Cloning Recombinant DNA is DNA that has been created artificially. DNA from two or more sources is incorporated into a single

More information

Bioreactor System ERT 314. Sidang /2012

Bioreactor System ERT 314. Sidang /2012 Bioreactor System ERT 314 Sidang 1 2011/2012 Chapter 3:Types of Bioreactors Week 4-5 Handouts : Chapter 13 in Doran, Bioprocess Engineering Principles Background to Bioreactors The bioreactor is the heart

More information

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study MagSi Beads Magnetic Silica Beads for Life Science and Biotechnology study MagnaMedics Diagnostics B.V. / Rev. 9.2 / 2012 Wide range of products for numerous applications MagnaMedics separation solutions

More information

COLIFORM FILTERS. All filters listed on this page are white with black grids, 47 mm diameter, sterile.

COLIFORM FILTERS. All filters listed on this page are white with black grids, 47 mm diameter, sterile. COLIFORM FILTERS Which filters do I use for Fecal coliforms, and which do I use for Total coliforms? According to the 22 nd edition of Standard Methods, Procedure 9222B (Total Coliform MF-Procedure) and

More information

3M Purification Inc. Filter Systems for Small Molecule Pharmaceutical Purification

3M Purification Inc. Filter Systems for Small Molecule Pharmaceutical Purification 3M Purification Inc. Filter Systems for Small Molecule Pharmaceutical Purification 2 Filter Systems for Pharmaceutical Separations 3M Purification Inc. Core Filtration Applications 3M Purification Inc.

More information

Plasmid Midiprep Plus Purification Kit. Cat. # : DP01MD-P10/ DP01MD-P50 Size : 10/50 Reactions Store at RT For research use only

Plasmid Midiprep Plus Purification Kit. Cat. # : DP01MD-P10/ DP01MD-P50 Size : 10/50 Reactions Store at RT For research use only Plasmid Midiprep Plus Purification Kit Cat. # : DP01MD-P10/ DP01MD-P50 Size : 10/50 Reactions Store at RT For research use only 1 Description: The Plasmid Midiprep Plus Purification Kit provides simple

More information

F1 1/10 R&D BIOREACTORS/FERMENTORS

F1 1/10 R&D BIOREACTORS/FERMENTORS F1 1/10 R&D BIOREACTORS/FERMENTORS THE COMPANY Bionet is a specialist in Bioprocesses Engineering. We provide equipment (Bioreactors, Cross-Flow Filtration Systems and Cleaning-In-Place Systems) and advanced

More information

Tests to Support Sterility Claim. Imtiaz Ahmed

Tests to Support Sterility Claim. Imtiaz Ahmed Tests to Support Sterility Claim Imtiaz Ahmed Sterile Product As per TGO 77, a sterile product must comply with the requirements of the following tests: Sterility Test Bacterial Endotoxins Test Appendix

More information

Oxygen Sensor Probes. Options for a Wide Range of Sensing Environments. Sensors

Oxygen Sensor Probes. Options for a Wide Range of Sensing Environments. Sensors Oxygen Sensor Probes Oxygen sensor probes typically are available in a variety of designs and with each of our standard coating formulations (FOXY, FOSPOR and HIOXY). Custom probes and accessories are

More information

MicroElute Cycle-Pure Kit

MicroElute Cycle-Pure Kit MicroElute Cycle-Pure Kit D6293-00 5 preps D6293-01 50 preps D6293-02 200 preps MicroElute Gel Extraction Kit D6294-00 5 preps D6294-01 50 preps D6294-02 200 preps MicroElute DNA Clean Up Kit D6296-00

More information

Safe Environmental Analytics Sampling Sample Preparation Analysis. Soil. Air. Water

Safe Environmental Analytics Sampling Sample Preparation Analysis. Soil. Air. Water Safe Environmental Analytics Sampling Sample Preparation Analysis Air Soil Sampling and sample analysis Objective: An optimal filter material simplifies and supports the contamination-free sampling of

More information