CT post processing and low dose scanning
|
|
- Denis Daniels
- 5 years ago
- Views:
Transcription
1 CT post processing and low dose scanning Gabor Szell GE Healthcare CT Modality Manager EE Annual Scientific and Educational Meeting Innovations in Cardiothoracic Imaging May 2011, Tokuda Hospital Sofia
2 What CT users ask for? To go further in diagnostic capabilities, we need higher resolution To push the limits of CT research, we need dynamic imaging & more than HU To further develop CT imaging we need to drastically reduce dose See more, know more, less dose Vascular 5% Thorax 12% Cardiac 1% 1% Interventional 1% Extremities Spine 4% Other 0% Virtual Colonoscopy 0% Abdomen 29% Pelvis 19% Brain/Head/Neck 28%
3 Looking for an optimal solution the best compromise Spatial resolution Fine-cell Detector + Visualization of fine structure - Image noise IQ Low dose Opti-Dose + 4D Modulation + Bowtie filters ++ Iterative reconstruction Temporal resolution EBCT Dual Source CT + Temporal resolution - Spatial resolution - Fast Dual energy Coverage Flat-Panel CT + Volume acquisition - Large angle Blurring, Dose
4 Looking for an optimal solution the best compromise Spatial resolution m coverage with new GEMSTONE detector fast response Low dose Temporal resolution ASiR iterative recon on raw data up to 35 fps Veo TM - the new CT breakthrough 0.5ms fast kv Dual Energy spectral imaging Coverage up to 31.5 cm dynamic & perfusion imaging
5 From conventional to Iterative Reconstructions FBP: - Fast - Make assumptions - Sensitive to noise - Amplifies artifacts Projection based IR
6 Adaptive Statistical Iterative Reconstruction - Models noise root causes (photon statistics, object noise) - As a result noise can be extracted during image reconstruction throughout several iterations - same noise level at 50% less dose
7 ASiR: 0.22 msv Coronary CT Angio 5 beats Snapshot pulse acquisition X-Ray Exposure: 1.7 s 80 kv & 90 mas DLP = mgy.cm (Eqv dose = 0.22 msv*) * Obtained by IRCP, using an adult chest factor of 0.014*DLP
8 ASiR: 0.86 msv Thorax 100 kvp & mas DLP = 51 mgy.cm (Eff Dose* = 0.86 msv) * Obtained by EUR EN, using an adult chest factor of 0.017*DLP
9 ASiR: 1,42 msv Colonoscopy Prone & supine acquisitions DLP = mgy.cm Eqv dose = 1.42 msv* * Obtained by EUR EN, using an adult abdomen-pelvis factor of 0.017*DLP
10 ASiR: 3 msv Abdomen / Pelvis DLP = 192 mgy.cm Effective dose = 3,2 msv* * Obtained by EUR EN, using an adult abdomen-pelvis factor of 0.017*DLP
11 Introducing Veo TM Model Based IR Raw data FBP Direct Reconstruction ASiR SYSTEM NOISE STATISTICS REAL 3D SYSTEM OPTICS Veo FBP with iterative image space correction Limited dose reduction opportunity Improved image quality** at lower dose SYSTEM NOISE STATISTICS Exceptional image quality at the lowest dose CPU required CPU required CPU required The diagram compares three reconstruction methods currently applied by GE Healthcare. **Image quality measured as image standard deviation.
12 Improving resolution & reducing blooming effect FBP Veo Images courtesy of J.L. Sablayrolles, M.D.
13 Ultra low dose Chest follow-up 4mAs, 0.09mSv* FBP ASiR (50%) Typical CXR effective dose is about 0.06 msv. Source: Health Physics Society. Veo 100kV, 10mA, 0.4 rot 6.3DLP, 0.09mSv* 3.0mm 277mm * Obtained by EUR EN, using a chest factor of 0.014*D
14 450mm Ultra low dose Abdomen Pelvis 0.68mSv* FBP ASiR (50%) Veo 100kV, 35-44mA, 0.5 rot DLP 40, 0.68mSv* 0.625mm slice thickness * Obtained by EUR EN, using an abdomen factor of 0.015*DLP and a pe
15 Water Iodine Spectral Imaging Challenge: speed and registration Single tube ultra-fast dual energy switching 0.5 ms switching between two energies Full 50 cm FOV Raw data based processing Accuracy of material separation Access to monochromatic images (spectral) Separate tissues to characterize
16 Spectral Imaging- Clinical benefits Quantitative CT characterize the chemical compositions such as kidney stones Characterize small lesions help characterize enhancing vs nonenhancing lesions Optimize the contrast visualization with monochromatic imaging Reduce Metal and Beam Hardening Artifacts for clearer anatomical visualization
17 Quantitative Small Lesion Characterization Normalized Spectral HU Curves Clinical Value Spectral Curves aid physicians to graphically see the attenuation characteristic via ROI s, like iodinated contrast for characterization of lesions Normalized Spectral Curves allow clearer characterization Used in all anatomical areas to help characterize enhancing lesions vs. cysts or hemorrhagic lesions Quantify the material characteristics across all energy levels for a confident diagnosis Cases Courtesy of Dr. Hara
18 Spectral Imaging Improved Visualization Left Kidney Stone Clinical Value Evaluate for kidney stones when IV contrast is utilized MD Water image described as a virtual non-contrast like With IV contrast administered, GSI MD Water clearly shows a very small kidney stone in the left kidney Monochromatic 70 kev Water (Virtual non-contrast) Images courtesy of Dr. Amy Hara, Mayo Clinic Arizona
19 Spectral Imaging Pulmonary embolism Spectral 70 kev Image Iodine (Water) Color Map Iodine (Water) 70 kev w/roi Placements Spectral HU Curve Clinical value Thrombus in right pulmonary vein is depicted on 70 kev image MD Iodine images show clearly lung hypo perfusion resulting from the pulmonary emboli. This hypo perfusion is correlated with Nuclear medicine exam The spectral HU curve confirms a low contrast enhancement in the lung tissue surrounding the embolus. GSI allows physicians to evaluate lung perfusion defect resulting from pulmonary emboli
20 Metal Artifact Reduction Bilateral Hip Prosthetics Clinical value GSI with MARs can dramatically reduce metal artifacts Conventional 140 kvp image Conventional 140 kvp image 75 kev with MAR 75 kev with MAR 75 kev with MAR Metal / bone interface can be more easily appreciated GSI clearly shows loss of bone around the femoral prosthesis and soft tissue filling the metal-bone interface (Blue arrows) The intact bone around the lower part of the femoral prosthesis is also better seen (Red arrow)
21 Growing number of applications Neuro beam hardening correction Neuro clips Metal implants Lung perfusion Renal Stone characterization White/ grey matter differentiation CTA with implants Stent artefact reduction Lung nodules Virtual non-contrast imaging Brain hemorrhagecta calcium removal Endoleak assessmentlung vessels Gout
22 CT Advanced Technologies Spectral Imaging Iterative reconstruction Adaptive statistical IR Model Based IR Thank you!
23 Why spatial resolution is important in cardiac? 1. Calcium 2. Intracoronary stents 3. Moderate to severe stenosis 4. High heart rates, Arrhythmia 5. Bypass grafts - Native vessel heavily calcified 6. Dose Spatial resolution Spatial resolution Spatial resolution Temporal resolution Spatial resolution Image Noise /Dose
24 Highest Cardiac Spatial Resolution in the Industry 18.2 lp/cm Stent Follow-up Distal stents clearly visualized
25 Spectral Imaging Material Quantification Unusual example of quantifying renal calculi Renal stone passed by a 48 yo The stone was scanned using GSI GSI reports effective Z of 17.3 to 17.6 indicating Calcium Monohydrate. Lab analysis of the stone confirmed GSI finding Case and Data Courtesy of Dr Dowe at Atlantic Medical Imaging Chemical Composition Chemical Name Composition Formula Mineralogical Name Calcium Oxalate Monohydrate 80% CaC 2 O 4 H 2 O Whewellite Calcium Oxalate Dihydrate 10% CaC 2 O 4 2H 2 O Wheddellite Uric Acid 10% C 5 H 4 N 4 O 3 Urate
GE Healthcare. Revolution GSI. A Better Exam.
GE Healthcare Revolution GSI A Better Exam. Put yourself instantly at the forefront of spectral CT. Revolution* GSI is a new generation of CT that delivers consistently high-definition imaging, for confident
More informationGE Healthcare. Introducing Veo * on Discovery * CT750 HD Great care by design
GE Healthcare Introducing Veo * on Discovery * CT750 HD Great care by design Radiologists and clinicians demand the ultimate levels of clarity and detail in their images. In making an informed and confident
More informationLow-dose and High-resolution Cardiovascular Imaging with Revolution* CT
GE Healthcare Case study Low-dose and High-resolution Cardiovascular Imaging with Revolution* CT Jean-Louis Sablayrolles, M.D. Laurent Macron, M.D. Jacques Feignoux, M.D. Centre Cardiologique du Nord,
More informationGENESIS Edition. Transforming CT
GENESIS Edition Transforming CT Transforming clinical confidence Transforming patient experience Transforming your workspace GENESIS Edition Transforming CT Brought to you by the leaders in area detector
More information40TH ANNUAL MEETING. CTA Dose Reduction: Special Considerations in Children. Jeffrey C. Hellinger, MD FACC. October 13 16, 2012 Pasadena, CA
40TH ANNUAL MEETING October 13 16, 2012 Pasadena, CA CTA Dose Reduction: Special Considerations in Children Jeffrey C. Hellinger, MD FACC New York Cardiovascular Institute Lenox Hill Radiology and Medical
More informationGENESIS Edition Transforming CT
GENESIS Edition Transforming CT 2 Transforming clinical confidence Transforming patient experience Transforming your workspace GENESIS Edition Transforming CT Brought to you by the leaders in area detector
More informationPatient radiation dose and image quality optimization in CT. Optimiser la dose patient et la qualité image en scanner
Conférence SPIMED - 8 juin 2012 IQ Patient safety Dose Reduction Patient radiation dose and image quality optimization in CT Optimiser la dose patient et la qualité image en scanner Philippe Coulon, PhD.
More informationMaking Reliable Low-dose CT a Clinical Reality
Making Reliable Low-dose CT a Clinical Reality By Ramakrishnan RS, MD, DNB, Consultant Radiologist 1 ; George Joseph, MD, DMRD, Consultant Radiologist 2 ; and Sundar RK, BSc, DRT, DAMIT, Clinical Applications
More informationComputed tomography. High. performance. no trade-offs. Philips Ingenuity CT family
Computed tomography High performance no trade-offs Philips Ingenuity CT family Keeping you ahead Until now, CT scanning has too often been about trade-offs. You ve been forced to choose between high image
More informationThe Latest in Radiation Dose Reduction Techniques in CT
The Latest in Radiation Dose Reduction Techniques in CT Cynthia H. McCollough, PhD, FAAPM, FACR Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo Clinic,
More informationSpectral CT: A Brave New World of Quantitative, Functional Imaging
G E M S T O N E S P E C T R A L I M A G I N G C L I N I C A L V A L U E Spectral CT: A Brave New World of Quantitative, Functional Imaging CT has long been considered an excellent method for viewing high-resolution
More informationAdaptive Iterative Dose Reduction in 3D
technology history For over 130 years, Toshiba has been a world leader in developing technology to improve the quality of life. Our 50,000 global patents demonstrate a long, rich history of leading innovation.
More informationComputed Tomography: Optimization of acquisition protocols & Justification of clinical referrals. Koos Geleijns, medical physicist
Computed Tomography: Optimization of acquisition protocols & Justification of clinical referrals Koos Geleijns, medical physicist CT delivers excellent 3D image quality CT delivers excellent 3D image quality
More informationLow Dose, Lightning Speed, Latest Applications
RXL EDITION Low Dose, Lightning Speed, Latest Applications The New Standard for Radiology Toshiba Medical Systems is committed to the development of new technologies to minimize radiation dose while maintaining
More informationGE Healthcare. Optima * CT660 Second Edition
GE Healthcare Optima * CT660 Second Edition Your vision of quality care made real The Optima CT660 system helps you deliver competent, personalized care that helps fulfill your mission and please your
More informationFuture bound. Philips Ingenuity Core
Future bound Philips Ingenuity Core High reliability Low-dose, high-quality imaging and coverage, and the ability to personalize image quality* patient by patient. Expect excellence in routine imaging,
More informationRadiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology
Radiology Rounds A Newsletter for Referring Physicians Massachusetts General Hospital Department of Radiology Multi-Energy Computed Tomography - New Opportunities In Imaging the Abdomen Materials can be
More informationGE Healthcare. Introducing Discovery MI DISCOVERY MI
GE Healthcare Introducing Discovery MI DISCOVERY MI Introducing Discovery MI Introducing Discovery MI MEANINGFUL INSIGHTS. FROM YOUR PATIENT TO EVERY PATIENT. Meet Discovery TM MI. A PET/CT system conceptualized
More informationThe FUTURE has ARRIVED NeuViz 128
Contacts Middle East & North Africa No. 705/706, Building 26,Al-Baker Building, Dubai Healthcare City, UAE Tel: +971 4 4404885 North America 14425 Torrey Chase, Suite 100, Houston, TX 77014 Tel: +1 281
More informationTrusted Performance. Smart Investment. 80 detector row Ultra Helical CT
TM Trusted Performance. Smart Investment. 80 detector row Ultra Helical CT 2 High performance, highly economical Increased productivity and patient safety Maximum clinical capabilities Are you looking
More informationFast enough to stop the Capable of delineating Unprecedented imaging power for the. Virtual endoscopy. The gatewa
Fast enough to stop the Capable of delineating Unprecedented imaging power for the M U L T I S L I C E Virtual endoscopy The gatewa motion of a beating heart. anatomic structures as small as 0.25mm. earliest,
More informationOptima * CT520 Personalized CT solution
GE Healthcare Optima * CT520 Personalized CT solution Not for use or distribution in the United States Broader vis Fast acquisition, reconstruction, and post-processing meet clinical and workflow challenges.
More informationNeuViz The NEW Standard in Multi-Slice CT Scanners
NeuViz The NEW Standard in Multi-Slice CT Scanners Setting a New Pace in CT Evolution 2012 NeuViz 64 2008 NeuViz 16 2007 Over 1000 CT installations worldwide 2006 NeuViz Dual 2004 Neusoft forms a joint
More informationGE Healthcare. Revolution ACT. Your Aspirations. Realized.
GE Healthcare Revolution ACT Your Aspirations. Realized. Your Aspirations. Realized. Helping you feel MORE CONFIDENT about moving to the next level, CLINICALLY & ECONOMICALLY that s intelligent innovation.
More informationNeuViz. Computed TomographyPrime. Advanced, Value-Rich 128-Slice CT Technology
NeuViz Computed TomographyPrime Advanced, Value-Rich 128-Slice CT Technology Prime NeuViz Value-based healthcare, a new financial challenge Make your imaging budget go further. Hospitals are faced with
More informationExtending quality care to more people. Brivo CT315
GE Healthcare Extending quality care to more people. Brivo CT315 Big impact. Improving the quality of healthcare around the world is a goal we all share. But this can be a daunting challenge, with patients
More informationDual Source Flash Spiral for a scan speed of 458 mm/s
Core Technologies Dual Source Flash Spiral for a scan speed of 458 mm/s With Flash Spiral, dose values under 1 msv especially important for the most dose-sensitive patients are so frequent they can be
More informationNeuViz 64 In/En. Flagship Product. Contacts
Contacts Headquarters Neusoft Medical Systems Co., Ltd. No.16 Shiji Road, Hunnan Industrial Area Shenyang, 110179, Liaoning, China Email: zhang-dan@neusoft.com Africa Neusoft Medical Systems (Africa) Co.
More information8/1/2018. Optimization Strategies for Pediatric CT Imaging. Educational Objectives. Brain CT
Image Quality Radiation Dose Contrast Dose Sedation Optimization Strategies for Pediatric CT Imaging Samuel Brady, M.S. Ph.D. DABR samuel.brady@cchmc.org 8-1-218 @CincyKidsRad facebook.com/cincykidsrad
More informationClarity CT Technology
Clarity CT Technology WHITE PAPER January 2013 Using state of the art algorithms Sapheneia Clarity CT allows physicians to lower radiation dose when acquiring CT data while maintaining image quality. The
More informationCTA Throughout the Ages
CTA Throughout the Ages Suhny Abbara, MD Associate Professor, Harvard Medical School Director of Education, Cardiac MRCT Program Director Cardiovascular Imaging Fellowship, Massachusetts General Hospital
More informationHandzettel 1. CARE Right Computed Tomography, committed to the right dose Ivo Driesser Austin, July 22 nd 2014
CARE Right Computed Tomography, committed to the right dose Ivo Driesser Austin, July 22 nd 2014 Answers for life. Answers for life. Is 1 msv the right dose for every patient? Female, 54 Abdominal CT Male,
More informationLeading Canadian Pediatric Hospital Continues to Drive Dose Down for Sick Children
Leading Canadian Pediatric Hospital Continues to Drive Dose Down for Sick Children At Canada s premier pediatric hospital also recognized as one of the world s foremost pediatric healthcare institutions
More informationPatient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose
Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose ipatient is an advanced platform that delivers focused innovations to facilitate patient-centered
More informationA New Standard for the Future
technology history For over 130 years, Toshiba has been a world leader in developing technology to improve the quality of life. Our 50,000 global patents demonstrate a long, rich history of leading innovation.
More informationCT QA SOLUTIONS. Ensure Accurate Screening, Diagnosis and Monitoring ACCREDITATION CT IMAGE QUALITY QA CTDI CT CHARACTERIZATION CT PERFUSION QA
CT QA SOLUTIONS Ensure Accurate Screening, Diagnosis and Monitoring ACCREDITATION CT IMAGE QUALITY QA CTDI CT CHARACTERIZATION CT PERFUSION QA COMPLETE CT QA With more than 40 years of experience in the
More informationPower of BRANSIST safire in Neuroendovascular Therapy
Vascular Power of BRANSIST safire in Neuroendovascular Therapy Department of Radiology, Kinki University Hospital Suguru Ueda Mr. Suguru Ueda 1. Introduction Kinki University Hospital is located in the
More informationTable of Contents. Adaptive Diagnostics...7 Integrated Dose Reduction Streamlined Workflow Clinical Images... 26
2 Table of Contents Adaptive Diagnostics...7 Integrated Dose Reduction... 17 Streamlined Workflow... 21 Clinical Images... 26 3 AQUILION TM PRIME PROVIDES CLINICAL FLEXIBILITY, ENHANCED WORKFLOW FEATURES
More informationJonathon A. Nye, Ph.D Emory University School of Medicine Atlanta, GA
Artifacts related to CT Jonathon A. Nye, Ph.D Emory University School of Medicine Atlanta, GA Acknowledgements: Fabio Esteves MD 1, James Galt PhD 1, Perry Sprawls PhD 1, Robert Eisner PhD 2, James Hamill
More informationBrivo * CT385 Great care by design
GE Healthcare Brivo * CT385 Great care by design Not for sale or distribution in the United States. Built for total returns. Superb image quality. Advanced features. Compact size. All in one CT system
More informationTHE NEW 640 SLICE CT SCANNER
THE NEW 640 SLICE CT SCANNER www.ahdubai.com The American Hospital Dubai has recently acquired a state-ofthe-art computerized tomography (CT) scanner that houses a variety of intelligent and industry-leading
More informationMore flexibility More performance Less dose
2010 General Electric Company All rights reserved. GE and GE Monogram are trademarks of General Electric Company. GE Healthcare ASiR, Performix, microvoxel, Volara, and SmartView are trademarks of General
More informationFlash Speed. Lowest Dose.
Draft version www.siemens.com/healthcare Flash Speed. Lowest Dose. SOMATOM Definition Flash Answers for life. SOMATOM Flash SOMATOM Definition Flash 3 CT Vision Siemens CT Vision Today s reality Better
More informationGE Healthcare. Optima NM/CT 640
GE Healthcare Optima NM/CT 640 Great and lasting performance in a SPECT/CT system? Precisely. We invented hybrid SPECT/CT. And now we re perfecting it. Introducing the Optima* NM/CT 640 from GE Healthcare
More informationOptimisation in CT. A case for shared approach. Stephen J. Golding University of Oxford
Optimisation in CT A case for shared approach Stephen J. Golding University of Oxford Body CT 1979: 10 mm sections 20 second exposure 60 second reconstruction Body CT 2007 Submillimetre sections instant
More informationMeasurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method
Iran. J. Radiat. Res., 2004; 1(4): 187-194 Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method M.R. Ay 1, M. Shahriari 2, S. Sarkar 3, P.
More informationProgress Towards an International Image Quality Monitoring Framework for Quantitative Imaging
Progress Towards an International Image Quality Monitoring Framework for Quantitative Imaging Ricardo S. Avila rick.avila@accumetra.com October 2, 2017 Quantitative Imaging Workshop XIV Hubble Space Telescope
More informationThe World s First Adaptive Scanner
The World s First Adaptive Scanner SOMATOM Definition AS Excel Edition Answers for life. SOMATOM Definition AS Excel Edition 2 3 Siemens CT Vision Siemens CT Vision The justification for the existence
More informationR/F. Experiences Using SONIALVISION safire and the Utility of Tomosynthesis. 1. Introduction. 2. Basics of Tomosynthesis.
R/F Experiences Using SONIALVISION safire and the Utility of Tomosynthesis Radiology Division, Dokkyo Medical University Koshigaya Hospital Masahiro Nakajima Mr. Masahiro Nakajima 1. Introduction The hospital
More informationCT QA SOLUTIONS. Ensure Accurate Screening, Diagnosis and Monitoring
CT QA SOLUTIONS Ensure Accurate Screening, Diagnosis and Monitoring ACCREDITATION ADVANCED CT IMAGE QUALITY QA AUTOMATIC EXPOSURE CONTROL CT CHARACTERIZATION MULTI-ENERGY CT CT PERFUSION QA COMPLETE CT
More informationAAPM Scientific Meeting Imaging Symposium. State of the Art in Quantitative Imaging CT, PET and MRI. Which Imaging Modality is the Most Quantitative
AAPM Scientific Meeting Imaging Symposium State of the Art in Quantitative Imaging CT, PET and MRI Michael McNitt-Gray, PhD, FAAPM; UCLA Paul Kinahan, PhD, U. Washington Ed Jackson, PhD, FAAPM, UT-MD Anderson
More informationUGG, CT AND MRI- WHATS ON THE MENU CONSULTANT RADIOLOGIST- SURAKSHA DIAGNOSTIC CENTRE, SAINI ENCLAVE DR MONOJIT MONDAL MBBS,MD,DNB
UGG, CT AND MRI- WHATS ON THE MENU CONSULTANT RADIOLOGIST- SURAKSHA DIAGNOSTIC CENTRE, SAINI ENCLAVE DR MONOJIT MONDAL MBBS,MD,DNB THREE COURSE MENU COMPLIMENTARY NOT SUBSTITUTION USG/CT/MRI WHICH IS BETTER???
More information3D Filtered Backprojection Fundamentals, Practicalities, and Applications
. H. Siewerdsen et al. (AAPM 2011, Vancouver BC) For PPT slides, contact: jeff.siewerdsen@jhu.edu Education Image Reconstruction I 3D Filtered Backprojection Fundamentals, Practicalities, and Applications
More informationClinical Applications of the Latest Ultra-High-Resolution CT and Iterative Reconstruction Algorithm: Things Radiologist and Radiographer Need to Know
Clinical Applications of the Latest Ultra-High-Resolution CT and Iterative Reconstruction Algorithm: Things Radiologist and Radiographer Need to Know Poster No.: C-1477 Congress: ECR 2018 Type: Educational
More informationAbdominal CT with Single-Energy Metal Artifact Reduction (SEMAR): Initial Experiences
Abdominal CT with Single-Energy Metal Artifact Reduction (SEMAR): Initial Experiences Poster No.: C-0674 Congress: ECR 2014 Type: Scientific Exhibit Authors: K. Sofue 1, T. Yoshikawa 1, N. Negi 1, Y. Ohno
More informationExcellence in CT. SOMATOM Definition.
Excellence in CT SOMATOM Definition www.siemens.com/medical Contents SOMATOM Definition Dual Source CT Faster than Every Beating Heart Full Cardiac Detail at Half the Dose One-Stop Diagnosis in Acute
More informationwww.aquilionprime.com WARNING: Any reference to x-ray exposure, intravenous contrast dosage, and other medication is intended as a reference guideline only. The guidelines in this document do not substitute
More informationYour diagnostic partner. Every day. Optima* CT540
GE Healthcare Your diagnostic partner. Every day. Optima* CT540 At GE Healthcare, the goal was to design a CT system that would provide our clinical partners with the imaging capabilities needed every
More informationPrecision in Quantitative Imaging: Trial Development and Quality Assurance
Precision in Quantitative Imaging: Trial Development and Quality Assurance Susanna I Lee MD, PhD Thanks to: Mitchell Schnall, Mark Rosen. Dan Sullivan, Patrick Bossuyt Imaging Chain: Patient Data Raw data
More informationYour diagnostic partner. Every day. Optima* CT540
GE Healthcare Your diagnostic partner. Every day. Optima* CT540 At GE Healthcare, the goal was to design a CT system that would provide our clinical partners with the imaging capabilities needed every
More informationlow Dose, Lightning Speed
CXL edition low Dose, Lightning Speed Maximize the potential of today s clinical resources. In today s demanding healthcare environment, you need a CT system that satisfies all your requirements on a day-to-day
More informationSiemens Healthineers A paradigm shift in MRI and CT
Siemens Healthineers A paradigm shift in MRI and CT Ing. Federico Lensi Area Sales Specialist Imaging diagnostico in Sanità Stato Attuale e prospettive Pisa 20 Dicembre 2016 What are some of the challenges
More information7/28/2017. Michael Speidel. University of Wisconsin - Madison
Scanning-Beam Digital X-ray (SBDX) is a technology for real-time fluoroscopy and angiography in the cardiac cath lab Michael Speidel Characterized by high speed beam scanning with a 2D array of focal spots
More informationwww.aquilionprime.com WARNING: Any reference to x-ray exposure, intravenous contrast dosage, and other medication is intended as a reference guideline only. The guidelines in this document do not substitute
More informationAAPM ACTIVITIES WITH RESPECT TO CT IMAGING Cynthia McCollough, PhD, DABR, FAAPM, FACR, FAIMBE
AAPM ACTIVITIES WITH RESPECT TO CT IMAGING Cynthia McCollough, PhD, DABR, FAAPM, FACR, FAIMBE 1631 Prince Street, Alexandria, VA 22314 571-298-1300 www.aapm.org DISCLOSURES President-elect designate, AAPM
More informationA post-processing system uses these differential data to generate:
Iterative reconstruction in single source dual-energy CT pulmonary angiography: Is sufficient to achieve a radiation dose as low as state-of-the-art single-energy CTPA? Poster No.: B-0300 Congress: ECR
More informationOn the Importance of Computation in Clinical Radiology
On the Importance of Computation in Clinical Radiology Manuel Arreola, Ph.D., DABR Director of Radiological Physics Radiology Department University of Florida/Shands Healthcare My Disclaimer I ve received
More informationMaking the difference
Intuis Interventional X-ray Making the difference with Live Image Guidance Making the difference with Live Image Guidance Philips Intuis Together we make the difference in minimally invasive treatment
More informationInterventional Radiology
Angiography Systems Interventional Radiology *Pictured system is INFX-8000C Unprecedented Flexibility and Integration. Today s radiology interventions require speed, flexibility and high performance. Canon
More informationPerformance in CT SOMATOM Sensation
Performance in CT SOMATOM Sensation With the SOMATOM Sensation and z-sharp Technology, the future of volume imaging for cardiac and noncardiac applications has arrived. This scanner is the standard to
More informationCertainty lives in layers
Computed tomography Certainty lives in layers Philips IQon Elite Spectral CT Empowering the people behind the image 2 At Philips, we believe there s always a way to make life better which means breaking
More informationNew PET/CT from Siemens helps more patients benefit from premium technologies
Press Healthcare Erlangen, October 9, 2015 EANM 2015, Congress Center Hamburg (CCH) New PET/CT from Siemens helps more patients benefit from premium technologies Versatile new PET/CT system addresses a
More informationJessop M*(1), Thompson JD(2), Coward J(2), Sanderud A(3), Jorge J(4), Groot M de(5), Lança L(6), Hogg P(2).
Jessop M*(1), Thompson JD(2), Coward J(2), Sanderud A(3), Jorge J(4), Groot M de(5), Lança L(6), Hogg P(2). *Corresponding author 1.University of Salford; Brighton and Sussex University Hospitals NHS Trust
More informationThe time has come. Philips GEMINI TF PET/CT with TruFlight technology
The time has come Philips GEMINI TF PET/CT with TruFlight technology TruFlight has arrived Time-of-flight technology has always held the promise of better PET imaging. But it took Philips to harness its
More informationImaging anytime, anywhere.
Imaging anytime, anywhere. Vitrea Enterprise Suite Vitrea Enterprise Suite is Vital Images premier advanced visualization solution that provides clinical applications and data management systems, backed
More informationMaking the difference with Live Image Guidance
OncoSuite Interventional X-ray Making the difference with Live Image Guidance Next generation of Image Guided Therapy in Interventional Oncology Live Image Guidance in Interventional Oncology OncoSuite:
More informationComputed Tomography. Printed in Japan
Computed Tomography WARNING: Any reference to x-ray exposure, intravenous contrast dosage, and other medication is intended as a reference guideline only. The guidelines in this document do not substitute
More informationMinimum Detectability and Dose Analysis for Size- based Optimization of CT Protocols. Christopher Craig Smitherman
Minimum Detectability and Dose Analysis for Size- based Optimization of CT Protocols by Christopher Craig Smitherman Graduate Program in Medical Physics Duke University Date: Approved: Ehsan Samei, Supervisor
More informationA.K. Because edema should have attenuation of around zero Hounsfield units. D.A.B. Around water? A.K. Around water, yes.
Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis Radiology 2018; 286:205 213 Aleksander Kosmala,
More informationPropel your imaging abilities into the future.
GE Healthcare Propel your imaging abilities into the future. SIGNA CREATOR Imagine what MR can be. Leap ahead and create your future in imaging. Meet SIGNA Creator, named for its ability to help you create
More informationOptimisation of Clinical Protocols
Optimisation of Clinical Protocols K Pathmaraj MSc, BSc, Grad Dip Comp Science Chief Technologist (PET) Dept of Molecular Imaging & Therapy Austin Health, Victoria, Australia Senior Clinical Associate
More informationIntracranial stent visualization for image guided interventions and therapy
Intracranial stent visualization for image guided interventions and therapy Daniel Ruijters, Peter van de Haar, Ruben Roijers, Niels J. Noordhoek, Jan Timmer, and Drazenko Babic interventional X-Ray, Philips
More informationMaking the difference
Intuis Interventional X-ray Making the difference with Live Image Guidance Making the difference with Live Image Guidance Philips Intuis Together we make the difference in minimally invasive treatment
More informationLow radiation dose subtraction CT angiography (CTA) for diagnosis of peripheral arterial occlusive disease
Low radiation dose subtraction CT angiography (CTA) for diagnosis of peripheral arterial occlusive disease Poster No.: C-1978 Congress: ECR 2013 Type: Authors: Scientific Exhibit M. Suzuki 1, R. Tanaka
More informationBy completing this questionnaire, you are indicating your consent to participate in this research.
Introduction "Is your Imaging EuroSafe?" comprises a series of monthly surveys on CT DRLs for different indications, which are being carried out by the EuroSafe Imaging campaign, coordinated by the European
More informationOptimize efficiency with a universal system.
wins www.siemens.com/artis-one Optimize efficiency with a universal system.. Designed around you. Answers for life. Consistently efficient. Improve your competitiveness by mastering the balancing act between
More information2017 ACR Computed Tomography Quality Control Manual FAQS
Updated 11-15-2017 2017 ACR Computed Tomography Quality Control Manual FAQS Q. The updated 2017 ACR Computed Tomography Quality Control Manual has been released. (Visit www.acr.org/education/education-catalog.)
More informationClinical Applications. ImagingRite. Neuro Intervention. 1 ImagingRite
Clinical Applications ImagingRite Neuro Intervention 1 ImagingRite ImagingRite, a comprehensive suite of imaging tools offered with Infinix -i angiographic systems, was designed to assist clinicians in
More informationIntroducing a new take on efficient workflow: Deeply integrated clinical applications
Clinical Applications Introducing a new take on efficient workflow: Deeply integrated clinical applications The EXPERIENCE of TRUE CLINICAL APPLICATIONS While developments in image acquisition technology
More informationFrequently Asked Questions (FAQ's)
Frequently Asked Questions (FAQ's) Critical Comments on Proper Patient Centering 1. Using the UW protocols, I sometimes find that parts of the image are too noisy, particularly towards the posterior part
More informationEhsan Samei, PhD. Duke University
Ehsan Samei, PhD Duke University Duke CIPG Clinical Imaging Physics Group Medical Physics 2.0? A bold vision for an existential transition of clinical imaging physics 12 hrs didactic lectures on CT, MRI,
More informationComputed tomography. IQon Spectral CT. A scientific review of dual-energy and spectral computed tomography imaging
Computed tomography IQon Spectral CT A scientific review of dual-energy and spectral computed tomography imaging Contents 2 Introduction 4 The role of anatomical and tissue compositional information in
More informationSPECIFICATION. SPECT/CT Gamma Camera System
1. Scope SPECIFICATION SPECT/CT Gamma Camera System This specification describes the requirements for a dual-head SPECT/CT Gamma camera and work station solution (hereinafter referred as the System ),
More informationGE Healthcare LOGIQ P3. Advancing your imaging capabilities
GE Healthcare LOGIQ P3 Advancing your imaging capabilities Clear imaging to help inform diagnosis. The LOGIQ P3 incorporates the innovative technologies that have made GE Healthcare a trusted partner of
More informationAdvanced digital radiographic system powered by FlashPad.
GE Healthcare Discovery XR656 Plus Advanced digital radiographic system powered by FlashPad. Step up to the world of freedom. Discovery* XR656 Plus lets you enjoy productivity and workflow benefits thanks
More informationPhilips PET/CT Gemini GXL. Total performance. Total confidence.
Philips PET/CT Gemini GXL Total performance. Total confidence. Gemini GXL The one for all. Healthcare isn t about to slow down. Your best bet? 2 Accelerate. All patients. All applications. All the time.
More informationOptimization of Parameters in 16-slice CT-scan Protocols for Reduction of the Absorbed Dose
Iranian Journal of Medical Physics Vol. 11, No. 2 & 3, Spring & Summer 2014, 270-275 Received: March 10, 2014; Accepted: April 27, 2014 Original Article Optimization of Parameters in 16-slice CT-scan Protocols
More informationClinical Applications. ImagingRite. Interventional Radiology
Clinical Applications ImagingRite Interventional Radiology ImagingRite, a comprehensive suite of imaging tools offered with Infinix -i angiographic systems, was designed to assist clinicians in optimizing
More information