DRAFT. and ATX Master Roof Tile Underlay IRISH AGRÉMENT BOARD CERTIFICATION. CERTIFICATE No. 03/0103

Size: px
Start display at page:

Download "DRAFT. and ATX Master Roof Tile Underlay IRISH AGRÉMENT BOARD CERTIFICATION. CERTIFICATE No. 03/0103"

Transcription

1 IRISH AGRÉMENT BOARD BUILDING PRODUCT CERTIFICATION CERTIFICATE No. 03/0103 Cl/SfB (47) Ln6 Griltex S.A., 66 rue Leruste B.P Wattrelos Cedex, France. Telephone: Fax: Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master Roof Tile Underlay Sous-toiture Dachlattung The Irish Agrément Board is designated by Government to issue European Technical Approvals. Irish Agrément Board Certificates establish proof that the certified products are proper materials suitable for their intended use under Irish site conditions, and in accordance with the Building Regulations 1997 to The Irish Agrément Board operates in association with the National Standards Authority of Ireland (NSAI) as the National Member of UEAtc. PRODUCT DESCRIPTION: This Certificate relates to Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof tile underlays. These products are manufactured from polypropylene mesh reinforced polyethylene film for use as underlays on ventilated pitched roofs. The ATX Classic, ATX Classic I and ATX Classic N are microperforated, the ATX Master is not micro-perforated and has a non-woven polypropylene fabric on the bottom surface. USE: The products are used as underlays for ventilated pitched roofs. They prevent the ingress of wind-blown rain and snow. MANUFACTURE AND MARKETING These products are manufactured by: GRILTEX S.A. 66, rue Leruste B.P. 56 F Wattrelos Cedex Telephone: Fax: PART 1 CERTIFICATION 1.1 ASSESSMENT In the opinion of the Irish Agrément Board (IAB), Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof tile underlays are satisfactory for the purpose defined above, and can meet the requirements of the Building Regulations 1997 to 2002 as indicated in Section 1.2 of this Certificate. 1.2 BUILDING REGULATIONS 1997 to 2002 Requirement: D1 & D3 - MATERIALS AND WORKMANSHIP D3 Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof tile underlays, as certified in this Irish Agrément Board Certificate, are proper materials, fit for the intended use (see Part 4 of this certificate). D1 - Forst ATX Classic, ATX Classic I and ATX Classic N and ATX Master roof tile underlays, used in Readers are advised to check that this Certificate has not been withdrawn or superseded by a later issue by contacting: Irish Agrément Board, NSAI, Glasnevin, Dublin 9

2 accordance with this Irish Agrément Board Certificate meet the requirements for materials and workmanship. PART A - STRUCTURE A1 - Loading Tests indicate that a roof incorporating Forst ATX Classic, ATX Classic I, ATX Classic N, and ATX Master roof tile underlay can meet the requirements, provided the installation complies with the conditions set out in Section 2.4 and Part 3 of this Certificate. PART B - FIRE SAFETY B4 - External Fire Spread ATX Master roof tile underlays will not prejudice the external fire resistance of roofs as indicated in Section 4.1 of this Certificate. PART C - SITE PREPARATION AND RESISTANCE TO MOISTURE. C4 - Resistance to Weather and Ground Moisture ATX Master roof tile underlays can meet the requirements when installed as indicated in Parts 2 and 3 of this Certificate. PART F VENTILATION F2 - Condensation in Roofs ATX Master roof underlays which provide water PART 2 vapour permeability of the same order as quoted as a minimum for conventional roof tile underlays in BS 5534: Part 1: 1997 Code of Practice for slating and tiling - Design, and hence, movement of moisture vapour can take place through the underlay. The design guidelines contained in the Technical Guidance to Part F of the Building Regulations 1997 and BS 5250: 1989 (1995) Code of Practice for control of condensation in buildings, sections to must be met when installing this product. Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof underlay should be treated as an impermeable underlay when considering the ventilation requirements of the roof. PART L - CONSERVATION OF FUEL AND ENERGY L1 - Conservation of Fuel and Energy Based on the measured vapour resistance of Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof tile underlays, insulation can be installed at ceiling level to meet the requirements of Part L of the Building Regulations 1997 to Where the ceiling has to be fixed to the soffit of the rafters and insulation is to be fitted between the rafters as in dormer roof construction, ventilation should be arranged for as shown in Diagram 6D of the Technical Guidance Document to Part F of the Building Regulations 1997 to 2002 ; in these circumstances a vapour control layer must be installed at the warm side of the insulation. TECHNICAL SPECIFICATION AND CONTROL DATA 2.1 PRODUCT DESCRIPTION This certificate relates to Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof underlay which are designed for use as an unsupported underlay for tiled or slated ventilated pitched roofs, to protect the roof from the ingress of windblown rain, dust and snow when constructed in accordance with I.C.P. 2: 2002 Irish code of practice for slating and tiling. Forst roof underlays are manufactured from a laminate of polypropylene mesh reinforced polyethylene film. The ATX Classic, ATX Classic I and ATX Classic N are micro-perforated, the ATX Master is not microperforated and has a non-woven polypropylene fabric on the bottom surface. The Forst ATX Classic N is black in colour. Product Range The underlay is available in the following grades and sizes: Table 1. Properties Product ATX Classic ATX Classic I ATX Classic N ATX Master (flame retardant) Colour Natural Natural Black Black Weight kg/m Roll length (m) /50 Roll width (m) Roll weight (kg) /14 Wind loading (kpa) (with 350mm batten spacing and 600mm rafter centres) Mullen burst (knm-2)

3 Table 2. Typical values of service performance Material Water Vapour resistance Water Vapour Permeability MNs/g gm-2 Day-1 Forst ATX Classic, Classic I, Classic N Forst ATX Master Traditional felt underlay maximum (min) Polythene (0.15mm) Table 3. Minimum overlaps Roof Pitch Horizontal lap (mm) Vertical lap (mm) MANUFACTURE Forst ATX Classic, ATX Classic I and ATX Classic N roof underlay is produced by an extrusion process from polyethylene granules. Polypropylene mesh is bonded between extruded polyethylene films to complete the sheet manufacture. The Forst ATX Classic I then has a flame retardant applied to it. The sheet is microperforated at a rate of 5000 perforations per square metre, slit to width and rolled. The ATX Master is manufactured by a similar process but has an additional layer of non-woven polypropylene fabric laminated on the bottom surface. It is thus a four layer product and it is not micro-perforated Quality Control Quality control checks include visual inspection and checks on dimensions, tensile strength, roll weight and water vapour permeability. 2.3 DELIVERY, STORAGE AND MARKING Forst ATX Classic, ATX Classic I, ATX Classic N roof underlays are supplied in 50m rolls and the ATX Master in 30m or 50m rolls. Each roll lists the manufacturer's name, product description, IAB identification mark, IAB Certificate number and contains instructions on storage and installation. Rolls may be stored on end or laid flat and should be kept under cover. Care must be taken to avoid contact with solvents and with materials containing volatile organic components such as coal tar and timbers newly treated with creosote. The rolls must not be exposed to a naked flame or other ignition sources. 2.4 INSTALLATION PROCEDURE General Forst ATX Roof Underlays must be installed and fixed in accordance with the manufacturer's instructions, a copy of which should accompany each roll and the recommendations of ICP 2: 2002 Code of practice for slating and tiling and BS 5534: Part 1: 1997: Code of practice for Slating and Tiling- Design. Installation can be carried out in all conditions normal for roofing work Installation Installation of Forst ATX Roof Underlays can be carried out in all conditions normal to pitched roofing work. In roof construction it is important to remember that Forst ATX Roof Underlays are the second line of defence in excluding water penetrating the roof from the external environment. For this reason the following list of criteria must be met to comply with the requirements of this certificate. Ensure that: Forst ATX underlays are correctly installed and not damaged. Where Forst ATX underlays become damaged for whatever reason, it is imperative that it is suitably repaired with a new piece of the same material or a self-adhesive bituminous strip if the damage is minimal. During the operations of installing the roof underlays it is imperative that persons working on the roof do not use Forst ATX roof underlays for supporting themselves or the slates/tiles independently of the roof. Overlaps of the Forst ATX roof underlay must be provided in accordance with the minimum dimensions given in Table 3 of this certificate. Batten gauges should not exceed that recommended by the tile/slate manufacturer for the particular tile/slate being used. Moisture content of battens at time of fixing does not exceed 22%. Where underlay overlaps do not coincide with a batten, consideration should be given to either including an extra batten at the overlap or increasing the underlay overlap to coincide with the next batten. Where timbers on roofs have been treated with wood preservative due to high moisture content of timbers, it is essential that manufacturer's guidance be sought in relation to chemical attack on the roofing underlay.

4 When tacking Forst ATX Roof Underlays to the rafters it is recommended that a 3mm diameter X 20mm long extra large head felt nails of copper, aluminium alloy or galvanised steel be used. It is important that all tacking nails be covered by the overlap of the next underlay course so that the minimum overlap is maintained between the tacks and the lower edge of the overlap underlay. Forst ATX Roof Underlays are not suitable for use in flat roof construction. Where hips and valleys occur on roofs they should be covered with an additional layer of underlay overlapped at least 350mm on each side. This additional layer of underlay should run continuously from eaves to ridge. Forst ATX Roof Underlays must be laid horizontally across the roof. At ridge level Forst ATX Roof Underlays should be carried over the ridge with a minimum overlap of 225mm (Ref. Fig. 3). Where the length of the rafter slope measured on plan exceeds 6m, Forst ATX should only be installed in accordance with the manufacturer s guidance. Forst ATX Roof Underlays should be draped with a deflection of 10mm between rafters to direct the water vapour into the gutter. Ventilation requirements should be in accordance with Technical Guidance Document to Part F of the Building Regulations 1997 to Continuous eaves ventilation should be provided at a minimum rate Type 5U (to IS 36 or BS 747) roofing felt to be used at eaves with a 500mm overlap and dressed 50mm into the gutter or eaves facia tray to provide UV protection to the Forst ATX Roof Tile Underlay. Interlocking single lap tiles equivalent to 10mm continuous and ridge ventilation of 5mm per linear meter. Where continuous eaves ventilation is provided, the soffit vent should incorporate a fly screen to prevent birds and insects entering the roof void. To facilitate in the ventilation of the eaves, the use of proprietary eaves ventilators is strongly recommended as they ensure that quilt or loose fill insulation will not obstruct the flow of ventilating air where the insulation and roof meet. (Ref. Fig.2) Where proprietary roof space ventilation products are used they should perform satisfactorily as roofing products and should offer adequate resistance to wind load, deluges and driving rain and should not adversely affect the durability performance of the roof. Ridge ventilators must be used with the Forst ATX range of underlays and they should be installed in accordance with the manufacturer instructions. When installing the tile/slate/ridge ventilators it is important that an undercloak is inserted under the Forst ATX Roof Underlay to protect the opening from moisture running down the membrane. When fitting tile/slate ventilators they should be installed as close to the ridge as possible to increase ventilation circulation. (Ref. Fig.4). Where Forst ATX Roof Underlay are used in dormer roof construction i.e. where the ventilation is along the line of the rafters, a vapour control layer must be installed on the warm side of the insulation. Roof truss Forst ATX roofing tile underlay Tiling batten Insulation Tilting fillet At least equal to continuous strip 10mm wide or 25mm wide (subject to roof pitch/profile) Insulation on vapour barrier on plasterboard or insulation on foiled backed plasterboard Eaves ventilator providing unobstructed ventilation passage of a minimum 50mm over insulation is required Figure 1. Cold roof eaves detail for interlocking single lap tiles

5 A vapour control layer should be of minimum 500- gauge polyethylene with sealed laps or its equivalent. Forst ATX if exposed to UV light on a continuous basis, will degrade; therefore at eaves the use of a type 5U felt to IS 36 or BS 747 (1994) Specification for Roofing Felts must be used. This felt should be laid typically with a 500mm lap to the gutter, and be dressed 50mm into the gutter and be provided with a tilting fillet. (Ref. Fig. 1). Once Forst ATX Roof Underlay is installed, it should not be exposed to UV light for more than 1 month as it will degrade if exposed to UV light. Figure 2. Cold roof eaves detail for double lap fibre cement slates Double lap fibre cement slates Slate batten Type 5U (to IS 36 or BS 747) roofing felt to be used at eaves with a 500mm overlap and dressed 50mm into the gutter or eaves facia tray to provide UV protection to the Forst ATX Roof Tile Underlay. Forst ATX roof tile underlay Roof truss Tilting fillet Insulation At least equal to continuous strip 10mm wide or 25mm wide (subject to roof pitch/profile) Insulation on vapour barrier on plasterboard or insulation on foiled backed plasterboard Eaves ventilator providing unobstructed ventilation passage of a minimum 50mm over insulation is required Figure 3. Ridge detail Ridge tile. Ventilation must be provided with Forst ATX roof tile underlays at least equal to a continuous strip 5mm wide 225mm overlap at ridge Slate batten Roof truss Forst ATX roof tile underlay

6 Figure 4. Warm roof detail At least 50mm unobstructed air path between top of insulation and underside of Forst ATX Ridge ventilation equal to a 5mm continuous strip must be provided Tile/slate vent to achieve high level roof ventilation Batten fixed to underside of rafter to achieve 50mm air path A sealed vapour control barrier must be installed on the warm side of the insulation At least equal to a 25mm wide strip PART 3 DESIGN DATA 3 GENERAL ATX Master roof underlays provide a satisfactory underlay in tiled and slated, ventilated pitched roofs constructed in accordance with Irish Code of Practice ICP 2: 1986, Slating and Tiling, BS 5534: Part 1: 1997, Code of practice for slating and tiling and BS 8000: Part 6: 1990: (1997) Code of practice for slating and tiling of roofs and claddings. Strength Forst ATX Classic, ATX Classic I and ATX Classic N and ATX Master roof underlays will resist the loads associated with the installation of the roof. Forst ATX Classic, ATX Classic I and ATX Classic N and ATX Master roof underlays have adequate resistance to wind uplift forces in most locations in Ireland and may be considered equivalent in strength to Type 1F reinforced bitumen underlay as defined in BS 747:1994 Specification for roofing felts. Tests on Forst ATX Classic, ATX Classic I and ATX Classic N and ATX Master roof underlays fixed over rafters at 500 mm centres with batten centres at 330 mm have shown that the material does not extend unduly or tear around nail holes when subjected to a suction of up to 2.5 kpa. Design wind speeds should be determined and wind uplift forces calculated in accordance with BS 6399 Part 2: 1997, Code of Practice for Wind Loads. Weathertightness Tests confirm that Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof underlay will resist the passage of water, wind-blown snow and dust into the interior of a building under all conditions to be found in a roof constructed to Irish Code of Practice ICP 2: 1986, Slating and Tiling, BS 5534: Part 1: 1997, Code of practice for slating and tiling and BS 8000: Part 6: 1990: (1997), Code of practice for slating and tiling of roofs and claddings. For effective water management of a roof subject to severe driving rain conditions all underlays must be installed so that any water leaking through the roof tiles is carried by the underlay to the gutters. Ventilation Particular attention should be given to ensure that there is adequate ventilation to the roof space at both eaves and ridge levels. Slate/tile vents must be installed at the highest point to the ridge as is possible. Where the ceiling has to be fixed to the soffit of the rafters and insulation is to be fitted between rafters as in dormer roof construction, a continuous ventilation space of at least 50mm should be arranged for as shown in Diagram 6D of the Technical Guidance Document to Part F of the Building Regulations 1997 to 2002; a vapour control layer must be installed on the warm side of the insulation. It is essential that roofs are constructed so as to minimise the risk of moisture vapour entering the attic space and the formation of condensation. In accordance with good building construction practice, all openings for services and trap doors should be draught sealed, and trap doors should not be located in bathrooms, shower rooms or kitchens.

7 PART 4 TECHNICAL INVESTIGATIONS 4.1 BEHAVIOUR IN FIRE (1) Tests on Forst ATX Classic and ATX Master roof underlays indicate that there is a risk that fire can spread if the material is accidentally ignited during maintenance works, (eg roofer or plumbers torch). Forst ATX Classic 1 and Forst ATX Master both have fire retardant treatment. As with all types of sarking material, care must be taken during building and maintenance to avoid the material becoming ignited, (2) Toxicity - Negligible when used in a roof situation. 4.2 WATER PENETRATION Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof underlays when used in accordance with this Certificate, presents no significant risk of water penetration. 4.3 RISK OF WATER VAPOUR PENETRATION AND CONDENSATION ATX Master roof underlays provide water vapour permeability of the same order as quoted as a minimum for conventional roof tile underlays in, BS 5534: Part 1: 1997, Code of practice for slating and tiling - Design, and hence, some movement of moisture vapour can take place through the overlaps of the underlay. This standard also describes the factors to be considered in reducing condensation to a satisfactory minimum. The design guidelines contained in the Technical Guidance Document F Ventilation of the Building Regulations 1997 to 2002 and BS 5250: 1989; (1995) Code of practice for control of condensation in buildings, sections to must be met when installing this product. ATX Master roof underlays should be treated as an impermeable underlays when considering the ventilation requirements of the roof. Typical values of water vapour resistance for Forst ATX Classic, ATX Classic I, ATX Classic N and ATX Master roof underlays and other roof sarking materials are given in Table DURABILITY ATX Master roof underlays are virtually unaffected by conditions normally found in a roof space and will have a life comparable with that of Type 1F bitumen underlay. 4.5 TESTS AND ASSESSMENTS WERE CARRIED OUT TO DETERMINE THE FOLLOWING: Density Water vapour resistance Dimensional accuracy Tear strength Elongation at break Dimensional stability UV stability Efficiency of the construction process 4.6 OTHER INVESTIGATIONS (I) Existing data on product properties in relation to fire, toxicity, environmental impact and the effect on mechanical strength/stability and durability were assessed. (ii) The manufacturing process was examined including the methods adopted for quality control, and details were obtained of the quality and composition of the materials used. (iii) Site visits were conducted to assess the practicability of installation and the history of performance in use of the product. (iv) Driving rain resistance was assessed. (v) A condensation risk analysis was performed. Table 4. Physical Properties ATX Master Test (units) Method* Mean results Machine Direction Cross Direction Tensile strength IS EN ISO (N/50mm) (Speed 500 mm/min) Elongation at break % IS EN ISO (Speed 500 mm/min) Nail tear resistence (N) MOAT 27 ( 5.4.1) Resistance to water pressure Ad hoc 40mm. (Minimum)

8 PART 5 CONDITIONS 5.1 CONDITIONS OF CERTIFICATION The National Standards Authority of Ireland ( NSAI ) following consultation with the Irish Agrément Board ( IAB ) has assessed the performance and method of installation of the product/process and the quality of the materials used in its manufacture and certifies the product/process to be fit for the use for which it is certified provided that it is manufactured, installed, used and maintained in accordance with the descriptions and specifications set out in this certificate and in accordance with the manufacturer s instructions and usual trade practice. This certificate shall remain valid so long as: (a) the specification of the product is unchanged; (b) the Building Regulations, 1997 to 2002 and any other regulation or standard applicable to the product/process, its use or installation remain unchanged; (c) the product continues to be assessed for the quality of its manufacture and marking by NSAI; (d) no new information becomes available, which in the opinion of the NSAI would preclude the granting of the certificate; (e) the product or process continues to be manufactured, installed, used and maintained in accordance with the description, specifications and safety recommendations set out in this certificate. 5.2 The IAB mark and certification number may only be used on or in relation to products/processes in respect of which a valid certificate exists. If the certificate becomes invalid, the certificate holder must not use the IAB mark and certification number and must remove them from products already marked. 5.3 In granting this certificate, the NSAI makes no representation as to: (a) the presence or absence of patent rights subsisting in the product/process; or (b) the legal right of the certificate holder to market, install or maintain the product/process; or (c) whether individual products have been manufactured or installed by the certificate holder in accordance with the descriptions and specifications set out in this certificate. 5.4 This certificate does not comprise installation instructions and does not replace the manufacturer s directions or any professional or trade advice relating to use and installation which may be appropriate. 5.5 Any recommendations contained in this certificate relating to the safe use of the certified product or process are preconditions to the validity of the certificate. However, the NSAI does not certify that the manufacture or installation of the certified product or process in accordance with the descriptions and specifications set out in this certificate will satisfy the requirements of the Safety, Health and Welfare at Work Act, 1989 or of any other current or future statute or current or future common law duty of care owed by the manufacturer or by the certificate holder. 5.6 The NSAI is not responsible to any person or body for loss or damage, including personal injury, arising as a direct or indirect result of the use of this product or process. 5.7 Where reference is made in this certificate to any Act of the Oireachtas, regulation made thereunder, statutory instrument, code of practice, national standards, manufacturer s instructions or similar publication, it shall be construed as reference to such publication in the form in which it is in force at the date of this certification. THE IRISH AGRÉMENT BOARD This Certificate No. 03/0103 is accordingly granted by NSAI to Griltex S.A. on behalf of The Irish Agrément Board. DATE OF ISSUE: November Readers may check that the status of this Certificate has not changed by contacting the Irish Agrément Board, NSAI, Glasnevin, Dublin 9. Ireland. Signed: Chief Executive, NSAI Telephone: (01) Telefax: (01) Revised 2003 IRISH AGRÉMENT BOARD BUILDING PRODUCT CERTIFICATION Irish Agrément Board NSAI Glasnevin Dublin 9 Ireland Telephone: (01) Telefax: (01)

Forst STX Master Breather Roof Tile Underlay

Forst STX Master Breather Roof Tile Underlay CI/SfB (47) Ln6 CERTIFICATE NO. 06/0245 Griltex, 66 Rue Leruste, 59392 Wattrelos, France. Tel: 0033 320817339 Fax: 0033 320817327 Forst STX Master Breather Roof Tile Underlay Souscouche de couverture en

More information

Roof Underlay. Sous-toiture Unterspannbahn für Schieferdach oder Ziegeldach

Roof Underlay. Sous-toiture Unterspannbahn für Schieferdach oder Ziegeldach CI/SfB (47) Ln6 CERTIFICATE No. 06/0240 Laydex Ltd. Unit 3 Allied Industrial Estate, Kylemore Road, Dublin 10 Tel: 01 6426600 Fax: 01 6426601 Email: sales@laydex.ie Website: www.laydex.com Roof Underlay

More information

Solitex WA Breathable Wall Protection Membrane

Solitex WA Breathable Wall Protection Membrane CI/SfB (42) Ln6 Solitex WA Breathable Wall Protection Membrane System de revetment Dachbelagsystem CERTIFICATE NO. 04/0210 Moll bauökologische Produkte GmbH, Rheintalstr. 35-43, 68723 Schwetzingen, Germany.

More information

Cromar Vent 3 and Vent 3 Classic Breathable Roofing Underlays

Cromar Vent 3 and Vent 3 Classic Breathable Roofing Underlays CI/SfB (47) Ln6 CERTIFICATE No. 07/0286 Cromar Building Products Ltd. Unit 3, the Maltings Ind Est, Doncaster Road, Whitley Bridge, North Yorkshire, DN14 0HH. Tel: 0044 1977 663133 Fax: 0044 1977 662186

More information

Solitex Plus & Solitex UD Vapour Permeable Roofing Underlays for Pitched Roofs Revétement D étanchéité Dachabdichtungen

Solitex Plus & Solitex UD Vapour Permeable Roofing Underlays for Pitched Roofs Revétement D étanchéité Dachabdichtungen CI/SfB (47) Ln6 CERTIFICATE NO. 02/0138 Moll Bauökologische Produkte GmbH, Pro Clima, Schwetzingen, Germany. Tel: 00353 (0)46 9432104 Fax: 00353 (0)46 9432435 Email: info@maccannandbyrne.ie Website: www.ecologicalbuildingsystems.com

More information

Corotop Breathable Membranes

Corotop Breathable Membranes CI/SfB (47) Ln6 IRISH AGRÉMENT BOARD CERTIFICATE NO. 11/0367 Laydex Ltd., Unit 3, Allied Industrial Estate, Kylemore Road, Dublin 10. T: 01 6426600 F: 01 6426601 Corotop Breathable Membranes Souscouche

More information

DuPont Tyvek SUPRO Vapour Permeable Roofing Underlays for Pitched Roofs Souscouche de couverture en tuiles Unterlage für Ziegeldach

DuPont Tyvek SUPRO Vapour Permeable Roofing Underlays for Pitched Roofs Souscouche de couverture en tuiles Unterlage für Ziegeldach CI/SfB (47) Ln6 IRISH AGRÉMENT BOARD CERTIFICATE NO. 04/0157 DuPont de Nemours (Luxembourg) S.à r.l., Rue General Patton, L-2984 Luxembourg. T: +352 3666 5885 E: tyvek.construction@dupont.com W: www.construction.tyvek.com

More information

KORE Lock Roof Insulation

KORE Lock Roof Insulation CI/SfB (29) IRISH AGRÉMENT BOARD CERTIFICATE NO. 05/0235 KORE Insulation, Kilnaleck, Co. Cavan, Ireland. T: +353 (0)49 4336998 F: +353 (0)49 4336823 E: info@kore-icf.com W: www.kore-system.com KORE Lock

More information

Permo Forte NG & Permo Light NG Roof Tile Underlays

Permo Forte NG & Permo Light NG Roof Tile Underlays CI/SfB (47) Ln6 IRISH AGRÉMENT BOARD CERTIFICATE NO. 03/0190 Klober Ltd., Unit 6F East Midlands Distribution Centre, Short Lane, Castle Donlington, Derbyshire DE74 2HA. T: +44 1332 813050 E: info@klober.co.uk

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 1 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN WARM NON-VENTILATED AND COLD VENTILATED ROOFS

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 1 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN WARM NON-VENTILATED AND COLD VENTILATED ROOFS DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com TYVEK ROOF LINING SYSTEMS

More information

KINGSPAN NILVENT ROOF TILE UNDERLAYS FOR USE IN WARM NON-VENTILATED OR COLD VENTILATED ROOF SYSTEMS

KINGSPAN NILVENT ROOF TILE UNDERLAYS FOR USE IN WARM NON-VENTILATED OR COLD VENTILATED ROOF SYSTEMS Kingspan Insulation Ltd Torvale Industrial Estate Pembridge, Leominster Herefordshire HR6 9LA Tel: 0870 850 8555 Fax: 0870 850 8666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com

More information

HIGH-PERFORMANCE ROOFING UNDERLAYS AND BUILDING MEMBRANES

HIGH-PERFORMANCE ROOFING UNDERLAYS AND BUILDING MEMBRANES .............................................. CI/SfB Ln6 Uniclass L6813 March 2010 HIGH-PERFORMANCE ROOFING UNDERLAYS AND BUILDING MEMBRANES...................................................................

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 2 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN ENERGY EFFICIENT COLD NON-VENTILATED ROOFS

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 2 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN ENERGY EFFICIENT COLD NON-VENTILATED ROOFS DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com Agrément Certificate

More information

HIGH-PERFORMANCE ROOFING UNDERLAYS AND TIMBER FRAME MEMBRANES

HIGH-PERFORMANCE ROOFING UNDERLAYS AND TIMBER FRAME MEMBRANES ...... CI/SfB Ln6 Uniclass L6813 June 2004 HIGH-PERFORMANCE ROOFING UNDERLAYS AND TIMBER FRAME MEMBRANES HIGH-PERFORMANCE ROOFING UNDERLAYS Roof underlays are required in virtually all modern tile and

More information

Protech Regular 870 Radon Resisting Membrane

Protech Regular 870 Radon Resisting Membrane CI/SfB Ln9 CERTIFICATE NO. 05/0104 BSK, Commissioners Road, Strood, Rochester, Kent ME2 4ED, United Kingdom. Tel: 0044 1634 292700 Fax: 0044 1634 291029 Email: sales@bsk-laminating.com Website: www.bsk-laminating.com

More information

Visqueen High Performance Radon Membrane

Visqueen High Performance Radon Membrane CI/SfB (47) Ln6 IRISH AGRÉMENT BOARD CERTIFICATE NO. 05/0214 Visqueen Building Products, Heanor Gate Ind Estate, Heanor, Derbyshire DE75 7RG, UK. T: 0044 845 302 4758 F: 0044 845 017 8663 E: enquiries@visqueenbuilding.co.uk

More information

Agrément Certificate 2009/367

Agrément Certificate 2009/367 Agrément Certificate 2009/367 Copyright Agrément South Africa, November 2009 The master copy of this document appears on the website: http://www.agrement.co.za Validity Users of any Agrément certificate

More information

Q-Mark Registration Schedule

Q-Mark Registration Schedule Q-Mark Registration Schedule Vapour Impermeable (Type HR) Roof Underlay Protect Membranes 2 Brooklands Road Sale Cheshire M33 3SS This Q-Mark Schedule is issued in accordance with our Terms and Conditions.

More information

Agrément Certificate 2011/384

Agrément Certificate 2011/384 Agrément Certificate 2011/384 Copyright Agrément South Africa, February 2011 The master copy of this document appears on the website: http://www.agrement.co.za Validity Users of any Agrément certificate

More information

Agrément Certificate 2014/469

Agrément Certificate 2014/469 ] Agrément Certificate 2014/469 Copyright Agrément South Africa, November 2014 The master copy of this document appears on the website: http://www.agrement.co.za Validity Users of any Agrément certificate

More information

Rhinoplast Super Gas Barrier & Rhinoplast Ultra Radon Barrier

Rhinoplast Super Gas Barrier & Rhinoplast Ultra Radon Barrier CI/SfB (L26) (A3j) IRISH AGRÉMENT BOARD CERTIFICATE No. 03/0177 Principal Building Products Ltd., Railmill Way, Parkgate, Rotherham S62 6JQ, UK. T: 0044 1709 780680 F: 0044 1709 781420 W: www.pbpltd.co.uk

More information

HARCON VPU VAPOUR PERMEABLE UNDERLAY FOR USE IN COLD NON-VENTILATED ROOFS

HARCON VPU VAPOUR PERMEABLE UNDERLAY FOR USE IN COLD NON-VENTILATED ROOFS Brett Martin Harcon Speedwell Industrial Estate Staveley Derbyshire S43 3JP Tel: 01246 280000 Fax: 01246 561111 e-mail: info@harcon.co.uk website: www.harcon.co.uk HARCON VPU VAPOUR PERMEABLE UNDERLAY

More information

TLX UV MEMBRANES TLX UV10, UV15 AND UV25 ROOF TILE UNDERLAYS FOR USE IN COLD VENTILATED AND WARM NON-VENTILATED PITCHED ROOF SYSTEMS

TLX UV MEMBRANES TLX UV10, UV15 AND UV25 ROOF TILE UNDERLAYS FOR USE IN COLD VENTILATED AND WARM NON-VENTILATED PITCHED ROOF SYSTEMS TLX Insulation Ltd Cardinal Point Rickmansworth Hertfordshire WD3 1RE Tel: 01923 498001 Fax: 01923 498004 e-mail: tlx@tlxinsulation.co.uk website: www.tlxinsulation.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN COLD NON-VENTILATED PITCHED ROOF SYSTEMS

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN COLD NON-VENTILATED PITCHED ROOF SYSTEMS Klober Ltd Unit 6F, East Midlands Distribution Centre Short Lane Castle Donington Derbyshire DE74 2HA Tel: 01332 813050 Fax: 01332 814033 e-mail: support@klober.co.uk website: www.klober.co.uk APPROVAL

More information

PROFELT BREATHABLE MEMBRANES

PROFELT BREATHABLE MEMBRANES Strukta Group Cherry Orchard Lane Churchfields Industrial Estate Salisbury Wiltshire SP2 7LD Tel: 033 33 21 00 13 Fax: 033 33 21 00 15 e-mail: sales@strukta.co.uk website: www.strukta.co.uk APPROVAL INSPECTION

More information

Supertec P4mm, PA 4mm and PA 4,5kg/m 2 Roof Waterproofing Systems Systém d étanchéité pour toitures Dachabdichtungen

Supertec P4mm, PA 4mm and PA 4,5kg/m 2 Roof Waterproofing Systems Systém d étanchéité pour toitures Dachabdichtungen CI/SfB (47) Ln6 IRISH AGRÉMENT BOARD CERTIFICATE NO. 07/0294 Pluvitec Spa, Via Quadrelli 69 37055 Roco all Adige, Italy Tel: 0039 045 6608111 Fax: 0039 045 6608177 Email :info@pluvitec.com Web: www.pluvitec.com

More information

HARCON VPU VAPOUR PERMEABLE UNDERLAY FOR USE IN WARM NON-VENTILATED AND COLD VENTILATED ROOFS

HARCON VPU VAPOUR PERMEABLE UNDERLAY FOR USE IN WARM NON-VENTILATED AND COLD VENTILATED ROOFS Brett Martin Harcon Speedwell Industrial Estate Staveley Derbyshire S43 3JP Tel: 01246 280000 Fax: 01246 561111 e-mail: info@harcon.co.uk website: www.harcon.co.uk Agrément Certificate 04/4145 Product

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 3 TYVEK SD2 AIR LEAKAGE BARRIER/VAPOUR CONTROL LAYER

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 3 TYVEK SD2 AIR LEAKAGE BARRIER/VAPOUR CONTROL LAYER DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com Agrément Certificate

More information

Agrément Certificate 11/4826 website: Product Sheet 1

Agrément Certificate   11/4826 website:   Product Sheet 1 SIG Roofing Supplies Ltd t/a SIG UK Exteriors Harding Way St Ives Cambridgeshire PE27 3YJ Tel: 014 466777 Fax: 014 302586 Agrément Certificate e-mail: info@sigroofing.co.uk 11/4826 website: www.sigroofing.co.uk

More information

Agrément Certificate 07/4420 website: Product Sheet 2

Agrément Certificate    07/4420 website:  Product Sheet 2 Mercury Building Products Ltd 114 Eckington Road Coal Aston Dronfield Sheffield S18 3AY Tel: 01246 292816 Fax: 01246 292867 Agrément Certificate e-mail: sales@vapfree.co.uk; danny@vaprfree.co.uk 07/4420

More information

JUTADACH BREATHER MEMBRANES FOR USE IN WARM NON-VENTILATED AND COLD VENTILATED ROOFS

JUTADACH BREATHER MEMBRANES FOR USE IN WARM NON-VENTILATED AND COLD VENTILATED ROOFS Juta a.s. Dukelska 417 544 15 Dvur Kralove n.l. Czech Republic Tel: 00 42 0499 314211 Fax: 00 42 0499 314210 e-mail: juta@juta.cz website: www.juta.cz APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Supertec P4mm, PA 4mm and PA 4,5kg/m 2 Roof Waterproofing Systems Systém d étanchéité pour toitures Dachabdichtungen

Supertec P4mm, PA 4mm and PA 4,5kg/m 2 Roof Waterproofing Systems Systém d étanchéité pour toitures Dachabdichtungen CI/SfB (47) Ln6 CERTIFICATE NO. 07/0294 Pluvitec Spa, Via Quadrelli 67/A, 37055 Roco all Adige, Italy Tel: 0039 045 6608111 Fax: 0039 045 6608132 Email :info@pluvitec.com Web: www.pluvitec.com Supertec

More information

Laydex Polysump Radon Sump

Laydex Polysump Radon Sump CI/SfB (L26) (A3j) IRISH AGRÉMENT BOARD CERTIFICATE No. 16/0386 Laydex Ltd, Unit 3 Allied Industrial Estate, Kylemore Road, Dublin 3. T: 01 6426600 W: www.laydex.ie Laydex Polysump Radon Sump Puisard au

More information

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN WARM NON-VENTILATED PITCHED ROOF SYSTEMS

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN WARM NON-VENTILATED PITCHED ROOF SYSTEMS Klober Ltd Unit 6F, East Midlands Distribution Centre Short Lane Castle Donington Derbyshire DE74 2HA Tel: 01332 813050 Fax: 01332 814033 e-mail: support@klober.co.uk website: www.klober.co.uk APPROVAL

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 3 DUPONT AIRGUARD CONTROL AIR LEAKAGE BARRIER/ VAPOUR CONTROL LAYER

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 3 DUPONT AIRGUARD CONTROL AIR LEAKAGE BARRIER/ VAPOUR CONTROL LAYER DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com Agrément Certificate

More information

Roofers Guide to Underslating Membranes

Roofers Guide to Underslating Membranes Roofers Guide to Underslating Membranes IKO is a worldwide enterprise, with more than 3000 employees, and manufacturing plants in Canada, the United States, United Kingdom, Belgium, Holland, France and

More information

Agrément Certificate 02/3932 website: Product Sheet 7

Agrément Certificate   02/3932 website:   Product Sheet 7 Icopal Ltd Barton Dock Road Stretford Manchester M32 OYL Tel: 0161 865 4444 Fax: 0161 865 8433 Page 1 of 9 Agrément Certificate e-mail: info.uk@icopal.com 02/3932 website: www.icopal.co.uk Product Sheet

More information

Agrément Certificate 10/4748 website: Product Sheet 1

Agrément Certificate   10/4748 website:   Product Sheet 1 Cromar Building Products Ltd Units 3, 4, 5 Northside Industrial Estate Selby Road Whitley Bridge North Yorkshire DN14 0GH Tel: 01977 663133 Fax: 01977 662186 Agrément Certificate e-mail: info@cromar.uk.com

More information

Supertec P4mm, PA 4mm and PA 4,5kg/m 2 Roof Waterproofing Systems Systém d étanchéité pour toitures Dachabdichtungen

Supertec P4mm, PA 4mm and PA 4,5kg/m 2 Roof Waterproofing Systems Systém d étanchéité pour toitures Dachabdichtungen CI/Sf B (47) Ln6 IRISH AGRÉMENT BOARD CERTIFICATE NO. 07/0294 Pluvitec Spa, Via Quadrelli 69 37055 Roco all Adige, Italy Tel: 0039 045 6608111 Fax: 0039 045 6608177 Email :info@pluvitec.com Web: www.pluvitec.com

More information

British Board of Agrément tel: Bucknalls Lane fax: Herts WD25 9BA 2015

British Board of Agrément tel: Bucknalls Lane fax: Herts WD25 9BA 2015 Don & Low Ltd Nonwovens Glamis Road Forfar Angus DD8 1EY Tel: 01307 452600 Fax: 01307 452610 e-mail: nonwovens@donlow.co.uk website: www.donlow.co.uk Agrément Certificate 99/3648 Product Sheet 1 DON &

More information

Alkorplan Roof Waterproof Membranes

Alkorplan Roof Waterproof Membranes CI/SfB (47) Ln6 CERTIFICATE NO. 03/0192 Renolit Belgium N.V., Industrie Park De Bruwaan 9, B9700 Oudenaarde, Belgium. Tel: +32 55 339711 Fax: +32 55 318658 Alkorplan Roof Waterproof Membranes Systéme d

More information

LOW-E FOIL INSULATION FOR PITCHED ROOFS, DRY LININGS AND FLOORS LOW-E FOIL INSULATION FOR USE IN PITCHED ROOF APPLICATIONS

LOW-E FOIL INSULATION FOR PITCHED ROOFS, DRY LININGS AND FLOORS LOW-E FOIL INSULATION FOR USE IN PITCHED ROOF APPLICATIONS Low-E UK Ltd Unit 48 Weaver Industrial Estate Blackburn Street Liverpool Merseyside L19 8JA Tel: 0151 494 9994 Fax: 0560 310 7699 e-mail: info@low-e.co.uk website: www.low-e.co.uk APPROVAL INSPECTION TESTING

More information

CI/SfB (47) Ln6 Uniclass Pr_25_57_51_66 April 2018 ROOF UNDERLAYS...

CI/SfB (47) Ln6 Uniclass Pr_25_57_51_66 April 2018 ROOF UNDERLAYS... CI/SfB (47) Ln6 Uniclass Pr_25_57_51_66 April 2018 ROOF UNDERLAYS................................ 2 .................................................................................. THE FUNCTION OF ROOF

More information

Date of Ninth issue: 27 February 2015 John Albon Claire Curtis-Thomas

Date of Ninth issue: 27 February 2015 John Albon Claire Curtis-Thomas Don & Low Ltd Nonwovens Glamis Road Forfar Angus DD8 1EY Tel: 01307 452600 Fax: 01307 452610 e-mail: nonwovens@donlow.co.uk website: www.donlow.co.uk Agrément Certificate 96/3220 Product Sheet 1 DON &

More information

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD REFLECTIVE

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD REFLECTIVE DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com APPROVAL INSPECTION

More information

Product Regulations Detail Sheet 1

Product Regulations Detail Sheet 1 Designated by Government to issue European Technical Approvals Electronic Copy Visqueen Building Products Zedcor Business Park Bridge Street Witney Oxfordshire OX8 6LJ Tel: 01993 776346 Fax: 01993 776233

More information

Kingspan Kooltherm K10, K10 Plus & K15 Insulation Products

Kingspan Kooltherm K10, K10 Plus & K15 Insulation Products CI/SfB (29) IRISH AGRÉMENT BOARD CERTIFICATE NO. 08/0321 Kingspan Insulation, Castleblayney, Co. Monaghan, Ireland. Tel: +353 (0)42 9795000 Fax: +353 (0)42 9754299 Email: info@insulation.kingspan.com Website:

More information

INTRODUCING THE NEW GUNDLE API RANGE OF LAMINATED ROOFING PRODUCTS

INTRODUCING THE NEW GUNDLE API RANGE OF LAMINATED ROOFING PRODUCTS INTRODUCING THE NEW GUNDLE API RANGE OF LAMINATED ROOFING PRODUCTS INSULATION MEMBRANES The latest addition to the Gundle range of products is the Durafoil insulation membranes. These membranes are all

More information

Protan G, GG and GX Roofing Membranes

Protan G, GG and GX Roofing Membranes CI/SfB (47) Ln6 CERTIFICATE NO. 06/0263 Protan AS, P.O. Box 420, NO-3002 Drammen, Norway. Tel: 0047 32221600 Fax: 0047 32221700 Web: www.protan.com Protan G, GG and GX Roofing Membranes Revetement d étanchéité

More information

Fibre cement slates. Cembrit Berona, Cembrit Berona Graphite, Cembrit Berona Xxtra, Cembrit Berona Stonedge, Cembrit Berona Structured

Fibre cement slates. Cembrit Berona, Cembrit Berona Graphite, Cembrit Berona Xxtra, Cembrit Berona Stonedge, Cembrit Berona Structured Fibre cement slates Cembrit Berona, Cembrit Berona Graphite, Cembrit Berona Xxtra, Cembrit Berona Stonedge, Cembrit Berona Structured Fibre cement slates PHOTO The Cembrit group are one of Europe s largest

More information

Thermakraft FIRE RETARDANT SELF SUPPORTING ABSORBENT BREATHABLE SYNTHETIC NON-WOVEN ROOF UNDERLAY STRENGTH BREATHER SHEET WATER RESISTANCE

Thermakraft FIRE RETARDANT SELF SUPPORTING ABSORBENT BREATHABLE SYNTHETIC NON-WOVEN ROOF UNDERLAY STRENGTH BREATHER SHEET WATER RESISTANCE CI/SfB MAY 2012 MEMBRANES OF THE FUTURE FIRE RETARDANT SELF SUPPORTING ABSORBENT BREATHABLE SYNTHETIC NON-WOVEN ROOF UNDERLAY STRENGTH BREATHER SHEET WATER RESISTANCE FLAMMABILITY < FLAMMABILITY INDEX

More information

Visqueen Building Products Maerdy Industrial Estate Rhymney Tredegar Gwent NP22 5PY Tel: Fax:

Visqueen Building Products Maerdy Industrial Estate Rhymney Tredegar Gwent NP22 5PY Tel: Fax: CI/SfB Visqueen Building Products Maerdy Industrial Estate Rhymney Tredegar Gwent NP22 5PY Tel: 01685 840672 Fax: 01685 842580 (13.9) n6 Agrément Certificate No 94/3009 Third issue* Designated by Government

More information

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide V1/0715/AI/TDO1 KORE Loft Insulated Flooring System Design Guide KORE Loft Insulated Flooring System Key Features Excellent thermal performance for the lifetime of the building Sheets tongue and grooved

More information

INTRODUCING THE NEW GUNDLE API RANGE OF LAMINATED ROOFING PRODUCTS

INTRODUCING THE NEW GUNDLE API RANGE OF LAMINATED ROOFING PRODUCTS INTRODUCING THE NEW GUNDLE API RANGE OF LAMINATED ROOFING PRODUCTS INSULATION MEMBRANES The latest addition to the Gundle range of products is the Durafoil insulation membranes. These membranes are all

More information

Regulations Detail Sheet 1

Regulations Detail Sheet 1 Electronic Copy Brett Martin Harcon Speedwell Industrial Estate Staveley Derbyshire S43 3JP Tel: 01246 280000 Fax: 01246 561111 e-mail: info@harcon.co.uk website: www.harcon.co.uk CI/SfB (52.5) In8 Agrément

More information

TRISO-SUPER 10 DATA SHEET

TRISO-SUPER 10 DATA SHEET 2010 Edition ACTIS THIN MULTIFOIL INSULATION DATA SHEET ROOFS ATTICS EUROPEAN TECHNICAL APPROVAL IN PROCESS Registration N 12.01/12 INSULATION FOR ROOFS AND ATTICS SPECIAL BENEFITS has been tested under

More information

Monarperm Systems. High performance for pitched roofs. Energy efficiency right under your roof WORLD LEADER IN BUILDING MEMBRANES. July 2006.

Monarperm Systems. High performance for pitched roofs. Energy efficiency right under your roof WORLD LEADER IN BUILDING MEMBRANES. July 2006. Monarperm Systems CI/SfB (47) Ln July 2006 High performance for pitched roofs Energy efficiency right under your roof ASSESSMENT OF PRODUCTS FOR CONSTRUCTION CERTIFICATE No 03/4062 CERTIFICATE No 02/3932

More information

Roofing and Cladding. ALTERNA NT-slate APPLICATION INSTRUCTIONS 11

Roofing and Cladding. ALTERNA NT-slate APPLICATION INSTRUCTIONS 11 Roofing and Cladding ALTERNA NT-slate APPLICATION INSTRUCTIONS 11 DOUBLE COVER SLATE LAYING SYSTEM 1. GENERAL Throughout the world slates have been traditionally laid on millions of roofs in a double cover

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

CERTIFICATE No VTT-C Date of issue

CERTIFICATE No VTT-C Date of issue NAME OF PRODUCT CERTIFICATE No VTT-C-9190-12 Date of issue 3.12.2012 CERTIFICATE HOLDER ACTIS SA Avenue de Catalogne 11300 Limoux France MANUFACTURER ACTIS SA PRODUCT DESCRIPTION is a vapour control multifoil

More information

Regulations Detail Sheet 1

Regulations Detail Sheet 1 Electronic Copy Monarflex Geomembranes Ltd Lyon Way St Albans Herts AL4 0LB Tel: 01727 830116 Fax: 01727 858998 CI/SfB (21) Ln9 Agrément Certificate No 00/3668 Designated by Government to issue European

More information

BS 5250:2011+A1:2016 CONTROL OF CONDENSATION IN BUILDINGS. ROOF VENTILATION EXPLAINED

BS 5250:2011+A1:2016 CONTROL OF CONDENSATION IN BUILDINGS. ROOF VENTILATION EXPLAINED CI/SfB (37.9) Uniclass Pr_30_9_29 November 2016 BS 20:2011+A1:2016 CONTROL OF CONDENSATION IN BUILDINGS. ROOF VENTILATION EXPLAINED BS 20:2011+A1:2016 CONTROL OF CONDENSATION IN BUILDING THE NEED FOR CONDENSATION

More information

Qual-PEX Plumbing, Central & Underfloor Heating Pipe

Qual-PEX Plumbing, Central & Underfloor Heating Pipe CERTIFICATE NO. 06/0067 Quality Plastics Ltd., P.O. Box 29, Whites Cross, Cork, Ireland. Tel: +353 (0)21 4884700 Fax: +353 (0)21 4884701 CI/SfB (23) K Qual-PEX Plumbing, Central & Underfloor Heating Pipe

More information

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD CONTROL AIR LEAKAGE BARRIER/VAPOUR CONTROL LAYER

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD CONTROL AIR LEAKAGE BARRIER/VAPOUR CONTROL LAYER DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 337660 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com TYVEK ROOF LINING SYSTEMS

More information

Bituminous Roofing Underlay & Valley Guard

Bituminous Roofing Underlay & Valley Guard CONTENTS SUMMARY OF FEATURES... 2 TECHNICAL INFORMATION... 2 Product Description... 2 Applications... 2 Product Information... 2 Handling & Storage... 5 Technical Data... 5 Installation Information...

More information

SPECIMEN COPY. Unipur Insulated Roof Panels IRISH AGRÉMENT BOARD. CERTIFICATE No. 03/0193 BUILDING PRODUCT CERTIFICATION

SPECIMEN COPY. Unipur Insulated Roof Panels IRISH AGRÉMENT BOARD. CERTIFICATE No. 03/0193 BUILDING PRODUCT CERTIFICATION IRISH AGRÉMENT BOARD BUILDING PRODUCT CERTIFICATION CERTIFICATE No. 03/0193 Cl/SfB (41) Pq4 Unilin Systems NV, Waregemstraat 112, B-8792 Desselgem, Belgium Tel: 0032 (0)56 73 50 91 Fax: 0032 (0)56 73 50

More information

SANDTOFT FLASHINGS KORAFLEX FLASHING SYSTEM

SANDTOFT FLASHINGS KORAFLEX FLASHING SYSTEM Sandtoft Roof Tiles Ltd Belton Road Sandtoft Doncaster South Yorkshire DN8 5SY Tel: 0844 9395 999 Fax: 0844 9359 950 e-mail: info@sandtoft.co.uk website: www.sandtoft.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

Bituminous Building Paper

Bituminous Building Paper CONTENTS SUMMARY OF FEATURES... 2 TECHNICAL INFORMATION... 2 Product Description... 2 Applications... 2 Product Information... 2 Handling & Storage... 5 Technical Data... 5 Installation... 5 Size Range

More information

Agrément Certificate 15/5274 website: Product Sheet 1

Agrément Certificate   15/5274 website:   Product Sheet 1 The A Proctor Group Ltd The Haugh Blairgowrie Perthshire PH10 7ER Tel: 01250 872261 Fax: 01250 872727 Agrément Certificate e-mail: contact@proctorgroup.com 15/5274 website: www.proctorgroup.com Product

More information

Qual-Pex Plumbing, Central & Underfloor Heating Pipe

Qual-Pex Plumbing, Central & Underfloor Heating Pipe CI/SfB (23)K CERTIFICATE NO. 06/0067 Quality Plastics Limited., P.O. box 29, Whites Cross, Cork. Ireland Tel: +353 (021) 4884700 Fax: +353 (021) 4884701 Qual-Pex Plumbing, Central & Underfloor Heating

More information

FINAL ACCEPTED DRAFT

FINAL ACCEPTED DRAFT Perform A/S Ndr. Stationsvej 4 DK-8721 Daugåard Denmark Tel: 001 45 7022 6230 Fax: 001 45 7022 6240 e-mail: perform@perform.dk website: www.perform.dk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland Product 1.1 Watergate-Plus is a fire retardant, flexible synthetic wall underlay for use under direct fixed and non-direct fixed wall cladding on timber and steel framed buildings. The product is manufactured

More information

PROOFEX ENGAGE Membrane d étanchéité Wasserdichtungsmittel. Regulations

PROOFEX ENGAGE Membrane d étanchéité Wasserdichtungsmittel. Regulations Electronic Copy Fosroc Limited Coleshill Road Tamworth Staffordshire B78 3TL Tel: 01827 262222 Fax: 01827 262444 e-mail: sales@fosrocuk.com website: www.fosrocuk.com CI/SfB (21) Ln9 Agrément Certificate

More information

ONDULINE BITUMINOUS CORRUGATED ROOFING MATERIALS ONDUTILE ROOF TILE UNDERLAY

ONDULINE BITUMINOUS CORRUGATED ROOFING MATERIALS ONDUTILE ROOF TILE UNDERLAY Onduline Building Products Ltd Eardley House 182 184 Campden Hill Road Kensington London W8 7AS Tel: 020 7727 0533 Fax: 020 7792 1390 e-mail: enquiries@onduline.net website: www.onduline.co.uk APPROVAL

More information

APPLICATION: Roof insulation warm pitched roof

APPLICATION: Roof insulation warm pitched roof 138 APPLICATION: Product: Jabroof Premium panel Jabroof Premium panel is specially designed to be incorporated into warm pitched-roof constructions to provide a high level of insulation to meet the current

More information

2 in 1 Breathable Multi-layer Insulation Blanket. Thermal insulation in a 40mm thin, flexible, multi-layer breathable membrane

2 in 1 Breathable Multi-layer Insulation Blanket. Thermal insulation in a 40mm thin, flexible, multi-layer breathable membrane 2 in 1 Breathable Multi-layer Insulation Blanket Thermal insulation in a 40mm thin, flexible, multi-layer breathable membrane 2 in 1 insulating breather membrane Non degradable maintaining thermal performance

More information

Co-extruded 3 Layer Films

Co-extruded 3 Layer Films Co-extruded 3 Layer Films INTRODUCING THE NEW GUNDLE SABS RANGE OF 3 LAYER CONSTRUCTION MEMBRANES Multi-layer co-extrusion has the following advantages: It has a cross-linking effect between the different

More information

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017]

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017] WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY This Appraisal replaces BRANZ Appraisal No. 695 (2010) BRANZ Appraisals Technical Assessments of products for building and construction. Product 1.1 Watergate-Plus

More information

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof. DELTA -VENT S Vapor Permeable (Breathable) Roof Underlayment Division 7 Thermal and Moisture Protection PART 1 GENERAL 1.1 SUMMARY A. This Section provides information regarding vapor permeable roof underlayment

More information

Rockwool Blown Cavity Wall Insulation System

Rockwool Blown Cavity Wall Insulation System CI/SfB (21) K IRISH AGRÉMENT BOARD CERTIFICATE NO. 05/0222 Rockwool Ltd., Unit 11, Northwood Court, Santry, Dublin 9. Tel: 01 4038456 Fax: 01 4038457 Email: info@rockwool.ie Rockwool Blown Cavity Wall

More information

Boost' R Hybrid Roof GENERAL INSTALLATION GUIDELINES GENERAL INFORMATION TOOLS / ACCESSORIES PRECAUTIONS -1- VIEW ACTIS HYBRID VIDEOS ON

Boost' R Hybrid Roof GENERAL INSTALLATION GUIDELINES GENERAL INFORMATION TOOLS / ACCESSORIES PRECAUTIONS -1- VIEW ACTIS HYBRID VIDEOS ON GENERAL INSTALLATION GUIDELINES Boost' R Hybrid Roof GENERAL INFORMATION BOOST R HYBRID ROOF is a breathable roof underlay with built-in thermal performance. BOOST R HYBRID ROOF is generally used for roof

More information

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP SECRET JOINING STRIP (GJS 1)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP SECRET JOINING STRIP (GJS 1) Filon Products Limited APPROVAL INSPECTION TESTING CERTIFICATION Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 2JQ Tel: 01543 687300 Fax: 01543 687303 TECHNICAL APPROVALS

More information

Bailey Roofing Systems Victoria Gardens Victoria Industrial Estate Burgess Hill West Sussex RH15 9NB Tel: Fax:

Bailey Roofing Systems Victoria Gardens Victoria Industrial Estate Burgess Hill West Sussex RH15 9NB Tel: Fax: CI/SfB Bailey Roofing Systems Victoria Gardens Victoria Industrial Estate Burgess Hill West Sussex RH15 9NB Tel: 01444 244330 Fax: 01444 244342 (47) Ln6 Agrément Certificate No 06/4375 Designated by Government

More information

SYNTHETIC SELF SUPPORT ROOFING UNDERLAY

SYNTHETIC SELF SUPPORT ROOFING UNDERLAY FIRE RETARDANT FAST WRAP FLAMESPEC SS ROOF UNDERLAY This Appraisal replaces BRANZ Appraisal No. 715 (2011) Amended 29 June 2018. BRANZ Appraisals Technical Assessments of products for building and construction.

More information

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP ABUTMENT SECRET GUTTER/SOAKER (GAS 1)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP ABUTMENT SECRET GUTTER/SOAKER (GAS 1) Filon Products Ltd Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 3JQ Agrément Certificate Tel: 01543 687300 Fax: 01543 687303 e-mail: sales@filon.co.uk 07/4492 website: www.filon.co.uk

More information

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+

NEW Not just a vapour control layer, it also acts as supplementary insulation! HCONTROL REFLEX+ NEW Not just a vapour control layer, it also acts as supplementary insulation! VAPOUR CONTROL LAYER WITH BUILT-IN THERMAL PERFORMANCE C-6044-10 hcontrol reflex+ Air leakage in buildings can lead to a significant

More information

GERARD ROOFING UNDERLAY

GERARD ROOFING UNDERLAY GERARD ROOFING UNDERLAY ROOFING UNDERLAY FACTS WHY ROOFING UNDERLAYS? Today roofing underlays, also called roof membranes or roof foils, are commonly used for securing attics and thermal insulation layers

More information

PAULOID SYNTHETIC ROOFING UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 984 [2017] Appraisal No. 984 (2017) BRANZ Appraisals

PAULOID SYNTHETIC ROOFING UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 984 [2017] Appraisal No. 984 (2017) BRANZ Appraisals PAULOID SYNTHETIC ROOFING BRANZ Appraisals Technical Assessments of products for building and construction. Judea Holdings Ltd T/A Paul Industries PO Box 308 Tauranga 3140 Free phone: 0800 330 320 Tel:

More information

GERARD ROOFING UNDERLAY

GERARD ROOFING UNDERLAY GERARD ROOFING UNDERLAY ROOFING UNDERLAY FACTS WHY ROOFING UNDERLAYS? Today roofing underlays, also called roof membranes or roof foils, are commonly used for securing attics and thermal insulation layers

More information

IMPORTANT INFORMATION ON THE USE OF INTERNALLY INSTALLED ROOF UNDERLAY LAP VENTILATORS. CI/SfB (47) Uniclass Pr_30_59_29 August 2018

IMPORTANT INFORMATION ON THE USE OF INTERNALLY INSTALLED ROOF UNDERLAY LAP VENTILATORS. CI/SfB (47) Uniclass Pr_30_59_29 August 2018 IMPORTANT INFORMATION ON THE USE OF INTERNALLY INSTALLED ROOF UNDERLAY LAP VENTILATORS CI/SfB (47) Uniclass Pr_30_59_29 August 2018 INTRODUCTION INTERNALLY INSTALLED UNDERLAY VENTILATORS As recent winters

More information

PRODUCT SHEET 1 TOUGHSHEET DAMP-PROOF MEMBRANES

PRODUCT SHEET 1 TOUGHSHEET DAMP-PROOF MEMBRANES CI/SfB (27.9) Ln6 Frank Mercer & Sons Ltd Chequerbent Works Manchester Road Chequerbent, Westhoughton Bolton Lancashire BL5 3JF Tel: 01942 841111 Fax: 01942 842388 e-mail: sales@toughsheet.co.uk website:

More information

MULTIFOIL INSULATION TLX SILVER AND TLX SILVER FB FOR PITCHED ROOFS

MULTIFOIL INSULATION TLX SILVER AND TLX SILVER FB FOR PITCHED ROOFS Web Dynamics Ltd Moss Lane Blackrod Bolton Lancashire BL6 5JB Tel: 01204 695666 Fax: 01204 695333 e-mail: tlx@webdynamics.co.uk website: www.webdynamics.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

FENTRIM SEALING TAPES

FENTRIM SEALING TAPES SIGA Cover AG Rütmattstrasse 7 Ruswil 6017 Switzerland Tel: 00 41 41 499 69 69 Agrément Certificate e-mail: siga@siga.swiss 16/5378 website: www.siga.swiss Product Sheet 1 SIGA AIR AND WEATHERTIGHTNESS

More information

BUILDBASE SUPPLIED BY IKO BREATHER MEMBRANE FOR USE IN TIMBER FRAME CONSTRUCTIONS

BUILDBASE SUPPLIED BY IKO BREATHER MEMBRANE FOR USE IN TIMBER FRAME CONSTRUCTIONS IKO PLC Appley Lane North Appley Bridge Wigan Lancashire WN6 9AB Tel: 01257 255771 Fax: 01257 252514 Agrément Certificate e-mail: technical.uk@ikogroup.com 15/5190 website: www.ikogroup.co.uk Product Sheet

More information

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION Insulation A4/6 TB055W AW2244 Issue 6 Oct 2017 WHITE-FACED THERMO REFLECTIVE INSULATION Innovative cross-linked closed cell insulation core 3-in-1 Insulation, vapour barrier and radiant barrier Helps achieve

More information

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110) Filon Products Limited Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 2JQ Tel: 01543 687300 Fax: 01543 687303 e-mail: sales@filon.co.uk website: www.filon.co.uk APPROVAL INSPECTION

More information

New versatile and effective dry fix solutions for the roofline and above

New versatile and effective dry fix solutions for the roofline and above Cavity trays Access panels Loft access doors Gas barrier and damp proofing accessories Under floor and through wall ventilation Cavity closers and stops Air leakage solutions New versatile and effective

More information

Flat roofs. Flat roof design. 2.3 Flat Roofs

Flat roofs. Flat roof design. 2.3 Flat Roofs Flat Roofs Flat roof design Condensation Thermal insulation and the flow of heat and water vapour through a construction are inextricably linked. The position of thermal insulation, vapour control layer

More information

Agrément Certificate 17/5466 website: Product Sheet 1 LEADAX FLASHINGS LEADAX

Agrément Certificate   17/5466 website:   Product Sheet 1 LEADAX FLASHINGS LEADAX Leadax BV Vlijtweg 4 8191 JP Wapenveld The Netherlands Tel: +31 085 065 37 46 Agrément Certificate e-mail: info@leadax.com 17/5466 website: www.leadax.com Product Sheet 1 This Agrément Certificate Product

More information

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description Roofing Product Data Sheet Edition 11.2014 / xtra UK Identification no. 02 09 45 05 100 0 000019 Version no. 03 S-Vap 5000E SA Self-adhesive Vapour Barrier Product Description S-Vap 5000E SA is a multi-layer

More information