1 Electronic Copy Brett Martin Harcon Speedwell Industrial Estate Staveley Derbyshire S43 3JP Tel: Fax: website: CI/SfB (52.5) In8 Agrément Certificate No 89/2153 Third issue* Designated by Government to issue European Technical Approvals HARCON GRP VALLEY TROUGH SECTIONS Produit d étanchéité pour toitures PRV Dachabdichtungen GFX Product Harcon GRP Valley Trough THIS CERTIFICATE RELATES TO HARCON GRP VALLEY TROUGH SECTIONS. Each product is for use in slated or tiled roofs constructed in accordance with the relevant requirements of BS 5534 : The products are for use to provide a weatherproof junction at changes of direction and materials. The products are manufactured and marketed by the Certificate holder. These Front Sheets must be read in conjunction with the accompanying Detail Sheets, which provide information to specific products. Regulations Detail Sheet 1 1 The Building Regulations 2000 (as amended) (England and Wales) The Secretary of State has agreed with the British Board of Agrément the aspects of performance to be used by the BBA in assessing the compliance of roof waterproofing systems with the Building Regulations. In the opinion of the BBA, Harcon GRP Valley Trough Sections, if used in accordance with the provisions of this Certificate, will meet or contribute to meeting the relevant requirements. Requirement: B4(2) External fire spread Data obtained on tests to BS : 1958, indicate that the use of the products will enable a roof to be unrestricted by this Requirement. See tinted areas of the Properties in relation to fire section of these Front Sheets. Requirement: C2(b) Resistance to moisture Tests for water resistance indicate that the products meet this Requirement. See the tinted area of the Weathertightness section of these Front Sheets. Requirement: Regulation 7 Materials and workmanship The products are acceptable materials. See the tinted area of the Durability section of these Front Sheets. Readers are advised to check the validity of this Certificate by either referring to the BBA s website ( or contacting the BBA direct (Telephone Hotline ).

2 Electronic Copy 2 The Building (Scotland) Regulations 2004 In the opinion of the BBA, Harcon GRP Valley Trough Sections, if used in accordance with the provisions of this Certificate, will satisfy or contribute to satisfying the various Regulations and related Mandatory Standards as listed below. Regulation: 8 Fitness and durability of materials and workmanship Regulation: 8(1) Fitness and durability of materials and workmanship The products can contribute to a construction satisfying this Regulation. See the tinted area of the Durability section of these Front Sheets and the Installation part of the accompanying Detail Sheets. Regulation: 9 Building standards construction Standard: 2.8 Spread from neighbouring buildings Data obtained from tests to BS : 1958, indicate that the use of the products will enable a roof to be unrestricted under this Standard, with reference to clauses (1)(2) and (1)(2). See the tinted areas of the Properties in relation to fire section of these Front Sheets. Standard: 3.10 Precipitation Tests for water resistance indicate that the use of the products will enable a roof to satisfy the requirements of this Standard, with reference to clauses (1)(2) and (1)(2). See the tinted areas of the Weathertightness section of these Front Sheets. Regulation: 12 Building standards conversions All comments given for this product under Regulation 9, also apply to this Regulation with reference to clause (1)(2) and Schedule 6 (1)(2). (1) Technical Handbook (Domestic). (2) Technical Handbook (Non-Domestic). 3 The Building Regulations (Northern Ireland) 2000 In the opinion of the BBA, Harcon GRP Valley Trough Sections, if used in accordance with the provisions of this Certificate, will satisfy or contribute to satisfying the various Building Regulations as listed below. Regulations: B2 Fitness of materials and workmanship The products are acceptable materials. See the tinted area of Durability section of these Front Sheets. Regulation: C4 Resistance to ground moisture and weather Tests for water resistance indicate that the use of the products can contribute towards enabling a roof to satisfy the requirements of this Regulation. See the tinted area of the Weathertightness section of these Front Sheets. Regulation: E5 External fire spread Data obtained from tests to BS : 1958, indicate that the use of the products will enable a roof to be unrestricted under the requirements of this Regulation. See the tinted areas of the Properties in relation to fire section of these Front Sheets. 4 Construction (Design and Management) Regulations 1994 (as amended) Construction (Design and Management) Regulations (Northern Ireland) 1995 (as amended) Information in this Certificate may assist the client, planning supervisor, designer and contractors to address their obligations under these Regulations. See section: 1 Description (1.2) (of the relevant Detail Sheet). 2

3 Technical Specification 5 Delivery and site handling Harcon GRP Valley Trough Sections are delivered to site in packs of 10. Each item bears the BBA identification mark incorporating the number of this Certificate. Packs should be stored flat on a clean, level surface. Design Data 6 General 6.1 Harcon GRP Valley Trough Sections are suitable for use on slated/tiled roofs constructed in accordance with the relevant requirements of BS 5534 : The sections should be cut to size with a finetoothed saw and can accept holes being drilled using a sharp drill bit. 7 Strength The products have adequate strength to resist impacts likely to occur during installation and use. 8 Weathertightness Test data confirm that the products will adequately resist the passage of moisture to the inside of the building and so meet the requirements of: England and Wales Approved Document C, Requirement C2(b) Section 6.0 Scotland Mandatory Standard 3.10 Northern Ireland Regulation C4. Electronic Copy 9 Properties in relation to fire 9.1 Samples of GRP, representative of that used in the manufacture of the products, when tested in accordance with BS : 1958, achieved an EXT.S.AA rating. 9.2 Samples of GRP, representative of that used in the manufacture of the products, when tested in accordance with BS : 1987, achieved a Class 3 surface spread of flame. 10 Maintenance Minimum maintenance is required and the smooth surface finish will inhibit the build-up of foreign matter. Damaged lengths can be replaced without having to remove adjacent lengths. 11 Durability Available test data and knowledge of the material suggest that the products, when installed in accordance with this Certificate, should have a life of at least 20 years. Bibliography BS : 1958 Fire tests on building materials and structures External fire exposure roof test BS : 1987 Fire tests on building materials and structures Method for classification of the surface spread of flame of products BS 5534 : 2003 Code of practice for slating and tiling (including shingles) 3

4 Conditions of Certification 12 Conditions 12.1 This Certificate: (a) relates only to the product that is named, described, installed, used and maintained as set out in this Certificate; (b) is granted only to the company, firm or person identified on the front cover no other company, firm or person may hold or claim any entitlement to this Certificate; (c) is valid only within the UK; (d) has to be read, considered and used as a whole document it may be misleading and will be incomplete to be selective; (e) is copyright of the BBA; (f) is subject to English law References in this Certificate to any Act of Parliament, Regulation made thereunder, Directive or Regulation of the European Union, Statutory Instrument, Code of Practice, British Standard, manufacturers instructions or similar publication, are references to such publication in the form in which it was current at the date of this Certificate This Certificate will remain valid for an unlimited period provided that the product and the manufacture and/or fabrication including all related and relevant processes thereof: (a) are maintained at or above the levels which have been assessed and found to be satisfactory by the BBA; (b) continue to be checked as and when deemed appropriate by the BBA under arrangements that it will determine; and Electronic Copy (c) are reviewed by the BBA as and when it considers appropriate In granting this Certificate, the BBA is not responsible for: (a) the presence or absence of any patent, intellectual property or similar rights subsisting in the product or any other product; (b) the right of the Certificate holder to market, supply, install or maintain the product; and (c) the actual works in which the product is installed, used and maintained, including the nature, design, methods and workmanship of such works Any recommendations relating to the use or installation of this product which are contained or referred to in this Certificate are the minimum standards required to be met when the product is used. They do not purport in any way to restate the requirements of the Health & Safety at Work etc Act 1974, or of any other statutory, common law or other duty which may exist at the date of this Certificate or in the future; nor is conformity with such recommendations to be taken as satisfying the requirements of the 1974 Act or of any present or future statutory, common law or other duty of care. In granting this Certificate, the BBA does not accept responsibility to any person or body for any loss or damage, including personal injury, arising as a direct or indirect result of the installation and use of this product. In the opinion of the British Board of Agrément, Harcon GRP Valley Trough Sections are fit for their intended use provided they are installed, used and maintained as set out in this Certificate. Certificate No 89/2153 is accordingly awarded to Brett Martin Harcon. On behalf of the British Board of Agrément Date of Third issue: 23rd March 2006 Chief Executive *Original Certificate issued 2nd February This revised version includes change of Certificate holder s name, and contact numbers, reference to the revised Regulations and Standards, and new Conditions of Certification. British Board of Agrément P O Box No 195, Bucknalls Lane Garston, Watford, Herts WD25 9BA Fax: mail@bba.star.co.uk website: For technical or additional information, contact the Certificate holder (see front page). For information about the Agrément Certificate, including validity and scope, tel: Hotline , or check the BBA website.

5 Electronic Copy CI/SfB (52.5) In8 Brett Martin Harcon HARCON GRP VALLEY TROUGHS TYPES A AND D Certificate No 89/2153 DETAIL SHEET 2 Third issue* Product THIS DETAIL SHEET RELATES TO HARCON GRP VALLEY TROUGHS TYPES A AND D, GRP VALLEY TROUGHS FOR USE ON TILED ROOFS. Tiled roofs must be constructed in accordance with the relevant requirements of BS 5534 : This Detail Sheet must be read in conjunction with the Front Sheets, which give the product s position regarding the Building Regulations, general information relating to the product, and the Conditions of Certification. Technical Specification Figure 2 Tile Valley Trough 1 Description 1.1 Harcon GRP Valley Troughs Types A and D are manufactured from glass-fibre/polyester laminates in a continuous process to the profiles shown in Figures 1 and 2. Sanded strips bonded along the upper surface of each edge provide a key for bedding the roof tiles in mortar. 1.2 The troughs are manufactured to the nominal specification: thickness (mm) 1.3 area weight (kgm 2 ) 1.83 width (mm) 360 (Type A) 410 (Type D) length (m) 1.8, 2.4, 3.0 sanded strip width (mm) 40 standard colour (1) grey/blue (1) Other colours are available to order. Figure 1 Harcon GRP Valley Troughs Types A and D sanded strips type A sanded strips type D all dimensions in mm mm valley boards set between rafters on noggings or alternative continuous 6 mm board 1.3 The valley troughs are produced with an angle between the two sides of 17 and can be readily adapted by bending to accommodate roof pitches from 5 to Quality control checks are performed on incoming materials, during production and on the final product. Checks on the final product include: visual inspection weight dimensions. Installation valley trough tile valley 2 General Installation of Harcon GRP Valley Troughs Types A and D should be in accordance with the manufacturer s instructions and the relevant recommendations of BS 5534 : 2003 and BS : Procedure 3.1 The use of valley boards, 12 mm boards supported on noggings between rafters or, Readers are advised to check the validity of this Detail Sheet by either referring to the BBA s website ( or contacting the BBA direct (Telephone Hotline ).

6 alternatively, 6 mm boards laid over rafters, is recommended. Valley troughs can be installed without the use of valley boards provided the trough is pushed down snugly against the rafters and is drilled and nailed correctly. However, there is a greater risk of mortar bedding being loosened, and foot traffic must be avoided. A heavier weight X grade valley trough weighing 2.4 kgm 2 reducing the need for valley boards is also available. 3.2 The valley should be lined first longitudinally with reinforced underlay one metre wide. A length of the trough should be pressed to a snug fit into the valley and the line of the outer edges marked. The pitch angle of the valley trough, originally 17, will adapt to suit pitches from 5 to Counter battens of similar size to the roofing battens should be fixed along the marked line to support the edges of the trough, using nails of a quality acceptable in good roofing practice. 3.4 Commencing at the foot of the valley, troughs should be nailed at 400 mm spacings to the counter battens through drilled holes. 3.5 Consecutive lengths of valley trough should be laid allowing a 150 mm overlap at the joints, finally trimming at the head and foot of the valley using a fine-toothed saw. 3.6 The tiles should be bedded onto mortar laid on the sanded strips, keeping the water channels clear. Technical Investigations The following is a summary of the technical investigations carried out on Harcon GRP Valley Troughs Types A and D. 4 Tests Samples of the troughs and representative samples of the material were supplied by the manufacturer for testing. Tests were carried out in accordance with MOAT No 9 : 1973 to determine: resin/glass ratio dimensions Electronic Copy tensile strength/elongation cross-breaking strength effect of elevated temperatures effect of water impact resistance. 5 Investigations 5.1 The results of fire tests on samples of GRP used in the manufacture of the product, carried out in accordance with BS : 1958 and BS : 1987 by an independent test authority, were assessed. 5.2 The manufacturing process was examined, including the methods adopted for quality control, and details were obtained of the quality and composition of the materials used. 5.3 A visit was made to a site in progress to assess the practicability of installation. 5.4 A visit was made to an existing site to examine the performance of the product. Bibliography BS : 1958 Fire tests on building materials and structures External fire exposure roof test BS : 1987 Fire tests on building materials and structures Method for classification of the surface spread of flame of products BS 5534 : 2003 Code of practice for slating and tiling (including shingles) BS : 1990 Workmanship on building sites Code of practice for slating and tiling of roofs and claddings MOAT No 9 : 1973 Directive for the Assessment of Products in Glass-Reinforced Polyester for use in Building On behalf of the British Board of Agrément Date of Third issue: 23rd March 2006 Chief Executive *Original Detail Sheet issued 2nd February This revised version includes change of Certificate holder s name and reference to the revised Building Regulations and Standards. British Board of Agrément P O Box No 195, Bucknalls Lane Garston, Watford, Herts WD25 9BA Fax: mail@bba.star.co.uk website: For technical or additional information, contact the Certificate holder (see front page). For information about the Agrément Certificate, including validity and scope, tel: Hotline , or check the BBA website.

7 Electronic Copy CI/SfB (52.5) In8 Brett Martin Harcon HARCON GRP SLATE VALLEY TROUGH TYPE B Certificate No 89/2153 DETAIL SHEET 3 Third issue* Product THIS DETAIL SHEET RELATES TO HARCON GRP SLATE VALLEY TROUGH TYPE B, A GRP SECTION FOR USE ON SLATED ROOFS. Slated roofs must be constructed in accordance with the relevant requirements of BS 5534 : This Detail Sheet must be read in conjunction with the Front Sheets, which give the product s position regarding the Building Regulations, general information relating to the product, and the Conditions of Certification. Technical Specification 1 Description 1.1 The Harcon GRP Slate Valley Trough Type B is manufactured from glass- fibre/polyester laminates in a continuous process to the profile shown in Figure 1. Figure 1 Harcon Trough Type B valley trough 12 mm valley boards set between rafters on noggings or alternative continuous 6 mm board all dimensions in mm slate valley 1.2 The sections are manufactured to the nominal characteristics: thickness (mm) 1.3 weight (kgm 2 ) 1.83 width (mm) 305 length (m) 1.8, 2.4, 3.0 standard colour (1) grey/blue (1) Other colours are available to order. 1.3 The troughs are produced with an angle between the two sides of 17 and can be readily adapted by bending to accommodate roof pitches from 5 to Quality control checks are performed on incoming materials, during production and on the final product. Checks on the final product include: visual inspection weight dimensions. Installation 2 General Installation of Harcon GRP Slate Valley Trough Type B should be in accordance with the manufacturer s instructions and the relevant recommendations of BS 5534 : 2003 and BS : Procedure 3.1 The use of valley boards, 12 mm boards supported on noggings between rafters or, alternatively, 6 mm boards laid over rafters, is recommended. Valley troughs can be installed without the use of valley boards provided the trough is pushed down snugly against the rafters and is drilled and nailed correctly. However, foot traffic must be avoided. A heavier weight X grade valley trough weighing 2.4 kgm 2 reducing the need for valley boards is also available. 3.2 The valley should be lined first longitudinally with reinforced underlay one metre wide. A length Readers are advised to check the validity of this Detail Sheet by either referring to the Index of Current BBA Publications or contacting the BBA direct (Telephone Hotline ).

8 of the trough should be pressed to a snug fit into the valley and the line of the outer edges marked. The pitch angle of the valley trough, originally 17, will adapt to suit pitches from 5 to Counter battens of similar size to the roofing battens should be fixed along the marked line to support the edges of the trough, using nails of a quality acceptable in good roofing practice. 3.4 Commencing at the foot of the valley, troughs should be nailed at 400 mm spacings to the counter battens through drilled holes. 3.5 Consecutive lengths of valley trough should be laid allowing a 150 mm overlap at the joints, finally trimming the head and foot of the valley using a fine-toothed saw. Technical Investigations Electronic Copy 5 Investigations 5.1 The results of fire tests on samples of GRP used in the manufacture of the product, carried out in accordance with BS : 1958 and BS : 1987 by an independent test authority, were assessed. 5.2 The manufacturing process was examined, including the methods adopted for quality control, and details were obtained of the quality and composition of the materials used. Bibliography BS : 1958 Fire tests on building materials and structures External fire exposure roof test BS : 1987 Fire tests on building materials and structures Method for classification of the surface spread of flame of products The following is a summary of the technical investigations carried out on Harcon GRP Slate Valley Trough Type B. 4 Tests Samples of the slate valley trough sections, and representative samples of the material were supplied by the manufacturer for testing. Tests were carried out in accordance with MOAT No 9 : 1973 to determine: density resin/glass ratio dimensions tensile strength/elongation cross-breaking strength effect of elevated temperatures effect of water soak impact resistance. BS 5534 : 2003 Code of practice for slating and tiling (including shingles) BS : 1990 Workmanship on building sites Code of practice for slating and tiling of roofs and claddings MOAT No 9 : 1973 Directive for the Assessment of Products in Glass-Reinforced Polyester for use in Building On behalf of the British Board of Agrément Date of Third issue: 23rd March 2006 Chief Executive *Original Detail Sheet issued 2nd February This revised version includes change of company name, reference to the revised Building Regulations and associated text. British Board of Agrément P O Box No 195, Bucknalls Lane Garston, Watford, Herts WD25 9BA Fax: mail@bba.star.co.uk website: For technical or additional information, contact the Certificate holder (see front page). For information about the Agrément Certificate, including validity and scope, tel: Hotline , or check the BBA website.

9 Electronic Copy CI/SfB (52.5) In8 Brett Martin Harcon HARCON GRP SECRET GUTTER TYPE C Certificate No 89/2153 DETAIL SHEET 4 Third issue* Product THIS DETAIL SHEET RELATES TO HARCON GRP SECRET GUTTER TYPE C, A GRP BONDING GUTTER FOR USE AS A SEAL AT THE JUNCTION OF OLD AND NEW ROOFS ON TERRACED, SEMI- DETACHED OR EXTENDED HOUSES. Roofs must be constructed in accordance with the relevant requirements of BS 5534 : This Detail Sheet must be read in conjunction with the Front Sheets, which give the product s position regarding the Building Regulations, general information relating to the product, and the Conditions of Certification. Technical Specification 1 Description 1.1 Harcon GRP Secret Gutter Type C sections are manufactured from glass-fibre/polyester laminate in a continuous process to the profile illustrated (see Figure 1) with a sanded strip bonded along the centre line of the upper surface to provide a key for bedding the roof tiles/slates in mortar. 1.3 Quality control checks are performed on incoming materials, during production and on the final product. Checks on the final product include: visual inspections weight dimensions. Installation Figure 1 Secret Gutter Type C 260 mm sanded strip 2 General Installation of Harcon GRP Secret Gutter Type C should be in accordance with the manufacturer s instructions and the relevant recommendations of BS 5534 : 2003 and BS : mm secret gutter 1.2 The sections are manufactured to the nominal characteristics: thickness (mm) 1.1 area weight (kgm 2 ) 1.5 total width (mm) 260 length (m) 1.8, 2.4, 3.0 sanded strip width (mm) 40 standard colour (1) grey/blue (1) Other colours are available to order. 3 Procedure 3.1 The underlay and battens over the joint area of the separating-wall should be made good. Battens may cross over the separating-wall without trimming. 3.2 The adjoining roof should be prepared by renewing any nails in the first 130 mm, and cutting the tiles or slates in the straight line mid-way over the separating-wall. 3.3 The gutter should be slid under undisturbed tiles or slates, approximately 115 mm, and nailed to the battens through drilled holes using nails of a quality acceptable to good roofing practice. 3.4 Consecutive lengths of valley trough should be laid allowing a 150 mm overlap at the joints and extending over the fascia board into the gutter. 3.5 The tiles or slates should then be fixed with a butt joint over the centre of the trough and bedded onto mortar or mastic laid on the sanded strip. The water channels must be left free from mortar or mastic. Readers are advised to check the validity of this Detail Sheet by either referring to the BBA s website ( or contacting the BBA direct (Telephone Hotline ).

10 Technical Investigations Electronic Copy Bibliography The following is a summary of the technical investigations carried out on Harcon GRP Secret Gutter Type C sections. 4 Tests Samples of the gutter and samples of the material, were supplied by the manufacturer for testing. Tests were carried out in accordance with MOAT No 9 : 1973 to determine: density resin/glass ratio dimensions tensile strength/elongation cross-breaking strength effect of elevated temperatures effect of water soak impact resistance. BS : 1958 Fire tests on building materials and structures External fire exposure roof test BS : 1987 Fire tests on building materials and structures Method for classification of the surface spread of flame of products BS 5534 : 2003 Code of practice for slating and tiling (including shingles) BS : 1990 Workmanship on building sites Code of practice for slating and tiling of roofs and claddings MOAT No 9 : 1973 Directive for the Assessment of Products in Glass-Reinforced Polyester for use in Building 5 Investigations 5.1 The results of fire tests on samples of GRP used in the manufacture of the product, carried out in accordance with BS : 1958 and BS : 1987 by an independent test authority, were assessed. 5.2 The manufacturing process was examined, including the methods adopted for quality control, and details were obtained of the quality and composition of the materials used. On behalf of the British Board of Agrément Date of Third issue: 23rd March 2006 Chief Executive *Original Detail Sheet issued 2nd February This revised version includes change of Certificate holder s name, and reference to the revised Building Regulations and Standards. British Board of Agrément P O Box No 195, Bucknalls Lane Garston, Watford, Herts WD25 9BA Fax: mail@bba.star.co.uk website: For technical or additional information, contact the Certificate holder (see front page). For information about the Agrément Certificate, including validity and scope, tel: Hotline , or check the BBA website.

11 Electronic Copy CI/SfB (52.5) In8 Brett Martin Harcon HARCON GRP DRY VALLEY TROUGHS TYPES DVA AND DVB Certificate No 89/2153 DETAIL SHEET 5 Product THIS DETAIL SHEET RELATES TO HARCON GRP DRY VALLEY TROUGHS TYPES DVA AND DVB, GRP VALLEY TROUGHS FOR USE ON TILED ROOFS. Tiled roofs must be constructed in accordance with the relevant requirements of BS 5534 : This Detail Sheet must be read in conjunction with the Front Sheets, which give the product s position regarding the Building Regulations, general information relating to the product, and the Conditions of Certification. Technical Specification Figure 1 Harcon GRP Dry Valley Troughs 1 Description 1.1 Harcon GRP Dry Valley Troughs Types DVA and DVB are manufactured from glass-fibre/ polyester laminates in a continuous process to the profiles shown in Figures 1 and The troughs are manufactured to the nominal specification: thickness (mm) 1.3 area weight (kgm 2 ) 1.64 width (mm) 330 (Type DVA) 355 (Type DVB) length (m) 1.8, 2.4, 3.0 standard colour (1) grey/blue (1) Other colours are available to order. 1.3 The valley troughs are produced at an angle and can be readily adapted by bending to accommodate roof pitches from 20 to Quality control checks are performed on incoming materials, during production and on the final product. Checks on the final product include: visual inspection weight dimensions. DVA shallow dr y fix valley (all dimensions in mm) DVB deep dr y fix valley Figure 2 Dry Valley Trough Types DVA and DVB dry fix valley trough valley board Readers are advised to check the validity of this Detail Sheet by either referring to the BBA s website ( or contacting the BBA direct (Telephone Hotline ).

12 Installation Electronic Copy Technical Investigations 2 General Installation of Harcon GRP Dry Valley Troughs Types DVA and DVB should be in accordance with the manufacturer s instructions and the relevant recommendations of BS 5534 : 2003 and BS : Procedure 3.1 The use of valley boards, 12 mm boards supported on noggings between rafters or, alternatively, 6 mm boards laid over rafters, is recommended. 3.2 The valley should be lined first longitudinally with reinforced underlay one metre wide. 3.3 Counter battens of similar size to the roofing battens to support the edge of the trough, should be fixed at the correct distance from the centre of the valley (varying according to roof pitch) using nails of a quality acceptable in good roofing practice. Ensure that the roof tile underlay is laid over the counter battens before fitting the tiling battens. The ends of the tiling battens should be firmly secured to the valley boards. 3.4 A section in the fascia board should be cut to allow the valley to run straight into the gutter without having to bend up over it. 3.5 A V shape should then be cut out at the end of the valley to fit neatly into the gutter. 3.6 Position the Dry Valley Trough by locating firmly between the counter battens. The eaves filler is located at the tail of any run to close the cavity and can be trimmed to suit, if necessary. 3.7 Fix the Dry Valley Trough by nailing at 400 mm centres. 3.8 Consecutive lengths of Dry Valley Troughs should be laid allowing a 150 mm overlap at the joints, finally trimming at the head and foot of the valley using a fine-toothed saw. 3.9 The tiles should be laid in accordance with the manufacturer s instructions. The following is a summary of the technical investigations carried out on Harcon GRP Dry Valley Troughs Types DVA and DVB. 4 Tests Samples of the troughs and representative samples of the material were supplied by the manufacturer for testing. Tests were carried out in accordance with MOAT No 9 : 1973 to determine: resin/glass ratio dimensions tensile strength/elongation cross-breaking strength effect of elevated temperatures effect of water impact resistance. 5 Investigations 5.1 The results of fire tests on samples of GRP used in the manufacture of the product, carried out in accordance with BS : 2004 and BS : 1987 by an independent test authority, were assessed. 5.2 The manufacturing process was examined, including the methods adopted for quality control, and details were obtained of the quality and composition of the materials used. 2

13 Bibliography BS : 2004 Fire tests on building materials and structures Classification and method of test for external fire exposure to roofs BS : 1987 Fire tests on building materials and structures Method for classification of the surface spread of flame of products BS 5534 : 2003 Code of practice for slating and tiling (including shingles) Electronic Copy BS : 1990 Workmanship on building sites Code of practice for slating and tiling of roofs and claddings MOAT No 9 : 1973 Directive for the Assessment of Products in Glass-Reinforced Polyester for use in Building On behalf of the British Board of Agrément Date of issue: 23rd March 2006 Chief Executive 3

14 Electronic Copy British Board of Agrément P O Box No 195, Bucknalls Lane Garston, Watford, Herts WD25 9BA Fax: mail@bba.star.co.uk website: For technical or additional information, contact the Certificate holder (see front page). For information about the Agrément Certificate, including validity and scope, tel: Hotline , or check the BBA website.

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110) Filon Products Limited Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 2JQ Tel: 01543 687300 Fax: 01543 687303 e-mail: sales@filon.co.uk website: www.filon.co.uk APPROVAL INSPECTION

More information

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX VALLEY TROUGHS (GDFVT 70 AND GDFVT 110)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX VALLEY TROUGHS (GDFVT 70 AND GDFVT 110) Filon Products Limited Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 2JQ Tel: 01543 687300 Fax: 01543 687303 e-mail: sales@filon.co.uk website: www.filon.co.uk APPROVAL INSPECTION

More information

Visqueen Building Products Maerdy Industrial Estate Rhymney Tredegar Gwent NP22 5PY Tel: Fax:

Visqueen Building Products Maerdy Industrial Estate Rhymney Tredegar Gwent NP22 5PY Tel: Fax: CI/SfB Visqueen Building Products Maerdy Industrial Estate Rhymney Tredegar Gwent NP22 5PY Tel: 01685 840672 Fax: 01685 842580 (13.9) n6 Agrément Certificate No 94/3009 Third issue* Designated by Government

More information

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD REFLECTIVE

TYVEK ROOF LINING SYSTEMS DUPONT AIRGUARD REFLECTIVE DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com APPROVAL INSPECTION

More information

KINGSPAN NILVENT ROOF TILE UNDERLAYS FOR USE IN WARM NON-VENTILATED OR COLD VENTILATED ROOF SYSTEMS

KINGSPAN NILVENT ROOF TILE UNDERLAYS FOR USE IN WARM NON-VENTILATED OR COLD VENTILATED ROOF SYSTEMS Kingspan Insulation Ltd Torvale Industrial Estate Pembridge, Leominster Herefordshire HR6 9LA Tel: 0870 850 8555 Fax: 0870 850 8666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com

More information

Regulations Detail Sheet 1

Regulations Detail Sheet 1 Electronic Copy Monarflex Geomembranes Ltd Lyon Way St Albans Herts AL4 0LB Tel: 01727 830116 Fax: 01727 858998 CI/SfB (21) Ln9 Agrément Certificate No 00/3668 Designated by Government to issue European

More information

CEMBRIT SLATES ZEELAND SLATES

CEMBRIT SLATES ZEELAND SLATES Cembrit a.s. Lidická 302 266 38 Beroun 3 Czech Republic Tel: 00 420 311 744111 Fax: 00 420 311 744248 e-mail: info@cembrit.cz website: www.cembrit.cz APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

KINGSPAN THERMAROOF TR21

KINGSPAN THERMAROOF TR21 CI/SfB Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 0870 8508555 Fax: 0870 8508666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com (47) Rn Agrément

More information

GRACE CONSTRUCTION PRODUCTS HYDROPHILIC WATERSTOPS ADCOR 500S

GRACE CONSTRUCTION PRODUCTS HYDROPHILIC WATERSTOPS ADCOR 500S APPROVAL INSPECTION TESTING CERTIFICATION Grace Construction Products Ltd 580/581 Ipswich Road Slough Berks SL1 4EQ Tel: 01753 490000 Fax: 01753 490001 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate

More information

CARPENTER LOFT INSULATION EASY LOFT FOR LOFT APPLICATIONS

CARPENTER LOFT INSULATION EASY LOFT FOR LOFT APPLICATIONS Carpenter Ltd Dinting Lodge Industrial Estate Glossop Derbyshire SK13 6LE Tel: 01457 861141 Fax: 01457 892424 e-mail: sales.uk@carpenter.com website: www.carpenter.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 1 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN WARM NON-VENTILATED AND COLD VENTILATED ROOFS

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 1 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN WARM NON-VENTILATED AND COLD VENTILATED ROOFS DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com TYVEK ROOF LINING SYSTEMS

More information

GENERAL MEMBRANE ROOF WATERPROOFING MEMBRANES PHOENIX STAR AND PHOENIX STAR MINERAL ROOF WATERPROOFING MEMBRANES

GENERAL MEMBRANE ROOF WATERPROOFING MEMBRANES PHOENIX STAR AND PHOENIX STAR MINERAL ROOF WATERPROOFING MEMBRANES General Membrane SpA Via Venezia 28 30022 Ceggia (VE) Italy Tel: 00 39 0421 322000 Fax: 00 39 0421 322800 e-mail: info@generalmembrane.it website: generalmembrane.it APPROVAL INSPECTION TESTING CERTIFICATION

More information

Building Regulations

Building Regulations Electronic Copy CI/SfB Akzo Nobel Powder Coatings Ltd Stoneygate Lane Felling Gateshead Tyne and Wear NE10 0JY Tel: 0191-469 6111 Fax: 0191-469 1560 (49) Vu Agrément Certificate No 91/2704 Second issue*

More information

CABERDEK. Date of First issue: 28 November 2008 Simon Wroe Greg Cooper

CABERDEK. Date of First issue: 28 November 2008 Simon Wroe Greg Cooper Norbord Ltd Station Road Cowie Stirling FK7 7BQ Tel: 01786 812921 Fax: 01786 817143 e-mail: info@norbord.net website: www.norbord.net APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION

More information

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN WARM NON-VENTILATED PITCHED ROOF SYSTEMS

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN WARM NON-VENTILATED PITCHED ROOF SYSTEMS Klober Ltd Unit 6F, East Midlands Distribution Centre Short Lane Castle Donington Derbyshire DE74 2HA Tel: 01332 813050 Fax: 01332 814033 e-mail: support@klober.co.uk website: www.klober.co.uk APPROVAL

More information

Agrément Certificate 17/5450 website: Product Sheet 1 FOSROC HYDRO-EXPANSIVE WATERSTOPS SUPERCAST SW

Agrément Certificate   17/5450 website:  Product Sheet 1 FOSROC HYDRO-EXPANSIVE WATERSTOPS SUPERCAST SW Fosroc Limited Drayton Manor Business Park Coleshill Road Tamworth Staffordshire B78 3XN Tel: 01827 262222 Fax: 01827 262444 Agrément Certificate e-mail: enquiryuk@fosroc.com 17/5450 website: www.fosroc.com

More information

YBS MULTI-LAYER INSULATION SUPERQUILT

YBS MULTI-LAYER INSULATION SUPERQUILT Yorkshire Building Services (Whitwell) Limited T/A YBS Insulation Crags Industrial Park Morven Street Creswell Derbyshire S80 4AJ Tel: 0844 99 100 44 e-mail: technical@ybsinsulation.com website: http://www.ybsinsulation.com

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 2 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN ENERGY EFFICIENT COLD NON-VENTILATED ROOFS

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 2 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN ENERGY EFFICIENT COLD NON-VENTILATED ROOFS DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com Agrément Certificate

More information

TRUSTSEAL HIGH-FRICTION SURFACING SYSTEM KEYGRIP EPOXY 924

TRUSTSEAL HIGH-FRICTION SURFACING SYSTEM KEYGRIP EPOXY 924 HAPAS Roads and Bridges Trustseal Ltd Unit 10 Southfield Industrial Estate Southfield Lane Whitwell, Worksop Nottinghamshire S80 4NW Tel: 01909 722662 Fax: 01909 720228 e-mail: info@trustseal.co.uk website:

More information

Regulations Detail Sheet 1

Regulations Detail Sheet 1 Marley Eternit Ltd Station Road Coleshill Birmingham B46 1HP Tel: 01763 264686 Fax: 01763 260384 e-mail: cladding@marleyeternit.co.uk website: www.marleyeternit.co.uk CI/SfB (41) Rq2 Agrément Certificate

More information

MULTIFOIL INSULATION PRODUCT SHEET 1 THINSULEX SILVER

MULTIFOIL INSULATION PRODUCT SHEET 1 THINSULEX SILVER CI/SfB Lh4 (M2) Web Dynamics Ltd Moss Lane Blackrod Bolton Lancashire BL6 5JB Tel: 01204 695666 Fax: 01204 695333 e-mail: thinsulex@webdynamics.co.uk website: www.webdynamics.co.uk Agrément Certificate

More information

RESITRIX ROOF WATERPROOFING SYSTEMS RESITRIX SK W WATERPROOFING SYSTEM

RESITRIX ROOF WATERPROOFING SYSTEMS RESITRIX SK W WATERPROOFING SYSTEM Phoenix Dichtungstechnik GmbH Eisenacher Landstrasse 70 D-99880 Walterhaussen Germany Tel: 00 49 40 7667 2807 Fax: 00 49 40 7667 2949 website: www.pdt-waterproofing.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

RIW LIQUID-APPLIED WATERPROOFING SYSTEMS

RIW LIQUID-APPLIED WATERPROOFING SYSTEMS RIW Ltd Arc House Terrace Road South Binfield Bracknell Berkshire RG42 4PZ Tel: 01344 397777 Fax: 01344 862010 e-mail: technical@riw.co.uk website: www.riw.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

WAVIN ROAD GULLIES. Date of First issue: 16 April 2014 Brian Chamberlain Claire Curtis-Thomas

WAVIN ROAD GULLIES. Date of First issue: 16 April 2014 Brian Chamberlain Claire Curtis-Thomas HAPAS Wavin Ltd Parsonage Way Chippenham Wiltshire SN15 5PN Tel: 01249 766600 Fax: 01249 443286 e-mail: info@wavin.co.uk website: www.wavin.co.uk WAVIN ROAD GULLIES APPROVAL INSPECTION TESTING CERTIFICATION

More information

BAKOR HOT-APPLIED MONOLITHIC STRUCTURAL WATERPROOFING SYSTEM BAKOR EV HOT-APPLIED MONOLITHIC MEMBRANE DAMP-PROOFING SYSTEM

BAKOR HOT-APPLIED MONOLITHIC STRUCTURAL WATERPROOFING SYSTEM BAKOR EV HOT-APPLIED MONOLITHIC MEMBRANE DAMP-PROOFING SYSTEM APPROVAL INSPECTION TESTING CERTIFICATION Bauder Ltd 70 Landseer Road Ipswich Suffolk IP3 1DH Tel: 01473 257671 Fax: 01473 230761 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate 06/4350 e-mail:

More information

PRODUCT SHEET 1 ARGETON TERRACOTTA RAINSCREEN CLADDING SYSTEM

PRODUCT SHEET 1 ARGETON TERRACOTTA RAINSCREEN CLADDING SYSTEM CI/SfB (27.9) Ln6 Telling Architectural Ltd Primrose Avenue Fordhouses Wolverhampton West Midlands WV10 8AW Tel: 01902 789777 Fax: 01902 398777 e-mail: info@telling.co.uk website: www.telling.co.uk Agrément

More information

FENTRIM SEALING TAPES

FENTRIM SEALING TAPES SIGA Cover AG Rütmattstrasse 7 Ruswil 6017 Switzerland Tel: 00 41 41 499 69 69 Agrément Certificate e-mail: siga@siga.swiss 16/5378 website: www.siga.swiss Product Sheet 1 SIGA AIR AND WEATHERTIGHTNESS

More information

TUFFPAVE THIN SURFACING SYSTEMS FOR HIGHWAYS TUFFPAVE 10 MM THIN SURFACING SYSTEM

TUFFPAVE THIN SURFACING SYSTEMS FOR HIGHWAYS TUFFPAVE 10 MM THIN SURFACING SYSTEM H A P A S Hanson Quarry Products Europe Ltd Hanson House 14 Castle Hill Maidenhead Berkshire SL6 4JJ Tel: 01628 774100 e-mail: enquiries@hanson.com website: www.hanson.co.uk TUFFPAVE THIN SURFACING SYSTEMS

More information

Regulations Detail Sheet 1

Regulations Detail Sheet 1 Electronic Copy H B Fuller Coatings Ltd 95 Aston Church Road Nechells, Birmingham B7 5RQ United Kingdom Tel: +44 (0)121-322 6900 Fax: +44 (0)121-322 6901 website: www.synthapulvin.co.uk www.synthatec.com

More information

Alcan Singen GmbH D Singen Germany Tel: Fax: website:

Alcan Singen GmbH D Singen Germany Tel: Fax: website: CI/SfB (41) Rn6 Alcan Singen GmbH D-78221 Singen Germany Tel: 00 49 77 31 80 0 Fax: 00 49 77 31 80 2845 e-mail: composites@alcan.com website: www.alucobond.com Designated by Government to issue European

More information

BALLYTHERM INSULATION BALLYTHERM BTR PITCHED ROOF INSULATION

BALLYTHERM INSULATION BALLYTHERM BTR PITCHED ROOF INSULATION Ballytherm Ltd Annagh Industrial Park Ballyconnell Co Cavan Ireland Tel: 00 353 49 9527000 Fax: 00 353 49 9527002 e-mail: info@ballytherm.ie website: www.ballytherm.ie APPROVAL INSPECTION TESTING CERTIFICATION

More information

SIKA HYDROPHILIC WATERSTOPS SIKASWELL A2010

SIKA HYDROPHILIC WATERSTOPS SIKASWELL A2010 Sika Ltd Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: technical@uk.sika.com website: www.sika.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

NOVABRIK MORTARLESS BRICK SYSTEM Parement extérieur Verkleidung Bedachung. Regulations

NOVABRIK MORTARLESS BRICK SYSTEM Parement extérieur Verkleidung Bedachung. Regulations CI/SfB Acheson & Glover 64 Old Moy Road Dungannon Co Tyrone BT71 6PU Tel: 028 8778 4208 Fax: 028 8778 4805 e-mail: novabriksales@acheson-glover.com website: www.acheson-glover.com/www.novabrik.com (21.9)

More information

EUROTHANE GP EUROTHANE GP PITCHED ROOF INSULATION

EUROTHANE GP EUROTHANE GP PITCHED ROOF INSULATION Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke on Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

TARMAC THIN SURFACING SYSTEMS FOR HIGHWAYS. ULTIPAVE 6 mm THIN SURFACING SYSTEM

TARMAC THIN SURFACING SYSTEMS FOR HIGHWAYS. ULTIPAVE 6 mm THIN SURFACING SYSTEM H A P A S Tarmac Trading Ltd Bickenhill Lane Solihull Birmingham B37 7BQ Tel: 0845 812 6400 Fax: 0845 812 6200 e-mail: enquiries@tarmac.com website: www.tarmac.com TARMAC THIN SURFACING SYSTEMS FOR HIGHWAYS

More information

ARCH TIMBER PROTECTION FIRE-RETARDANT TREATMENT DRICON

ARCH TIMBER PROTECTION FIRE-RETARDANT TREATMENT DRICON Arch Timber Protection Ltd t/a Lonza Wood Protection APPROVAL INSPECTION TESTING CERTIFICATION Wheldon Road Castleford West Yorkshire WF10 2JT Tel: 01977 714000 Fax: 01977 714001 TECHNICAL APPROVALS FOR

More information

TIMBERWISE DAMP-PROOF SYSTEMS DRIWISE

TIMBERWISE DAMP-PROOF SYSTEMS DRIWISE Timberwise (UK) Ltd 1 Drake Mews Gadbrook Way Gadbrook Park Cheshire CW9 7XF Tel: 01606 333636 Fax: 01606 334748 e-mail: hq@timberwise.co.uk website: www.timberwise.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

TYVEK CONSTRUCTION MEMBRANES DUPONT AIRGUARD REFLECTIVE

TYVEK CONSTRUCTION MEMBRANES DUPONT AIRGUARD REFLECTIVE DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 337660 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com APPROVAL INSPECTION

More information

PERMACRIB RETAINING WALLS Murs de soutènement Stützmauer. Regulations

PERMACRIB RETAINING WALLS Murs de soutènement Stützmauer. Regulations Designated by Government to issue European Technical Approvals Phi Group Ltd (a Keller company) Harcourt House Royal Crescent Cheltenham Gloucestershire GL50 3DA Tel: 0870 333 4122 Fax: 0870 333 4127 e-mail:

More information

PERMAROOF 500 LIQUID ROOF SYSTEM

PERMAROOF 500 LIQUID ROOF SYSTEM Permaroof UK Ltd Unit 1, Westway Cotes Park Industrial Estate Alfreton Derbyshire DE55 4QJ Tel: 0800 161 3722 Fax: 01773 608 408 Agrément Certificate e-mail: sales@permaroof.co.uk 16/5372 website: www.permaroof.co.uk

More information

VITRABOND RAINSCREEN CLADDING SYSTEMS VITRABOND FR ALUMINIUM COMPOSITE RAINSCREEN CLADDING PANELS

VITRABOND RAINSCREEN CLADDING SYSTEMS VITRABOND FR ALUMINIUM COMPOSITE RAINSCREEN CLADDING PANELS Valcan Ltd APPROVAL INSPECTION TESTING CERTIFICATION Unit 7 Robins Drive Castlefields Industrial Estate Bridgwater Somerset TA6 4DL Tel: 01278 428 245 Fax: 01278 425 662 TECHNICAL APPROVALS FOR CONSTRUCTION

More information

MULTIFOIL INSULATION TLX GOLD INSULATING BREATHER MEMBRANE FOR PITCHED ROOFS

MULTIFOIL INSULATION TLX GOLD INSULATING BREATHER MEMBRANE FOR PITCHED ROOFS TLX Insulation Ltd Moss Lane Blackrod Bolton Lancashire BL6 5JB Tel: 01204 695666 Fax: 01204 695333 e-mail: tlx@tlxinsulation.co.uk website: www.tlxinsulation.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

STIRLING LLOYD WATERPROOFING SYSTEMS INTEGRITANK

STIRLING LLOYD WATERPROOFING SYSTEMS INTEGRITANK Stirling Lloyd Polychem Ltd Union Bank King Street Knutsford Cheshire WA16 6EF Tel: 01565 633111 Fax: 01565 633555 e-mail: info@stirlinglloyd.com website: www.stirlinglloyd.com APPROVAL INSPECTION TESTING

More information

Agrément Certificate 17/5420 Product Sheet 1 ULTRA LIQUID POLYMERS ROOF WATERPROOFING SYSTEMS

Agrément Certificate   17/5420 Product Sheet 1 ULTRA LIQUID POLYMERS ROOF WATERPROOFING SYSTEMS Ultra Liquid Polymers Ltd 39 Everton Road Birkdale Merseyside PR8 4BT Tel: +44 (0) 3304 004457 Fax: +44 (0) 3304 004458 Agrément Certificate e-mail: info@ultra-polymers.com 17/5420 Product Sheet 1 ULTRA

More information

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 4LA Tel: 0870 8508555 Fax: 0870 8508666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com Agrément Certificate

More information

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM KVT Dichtungssysteme GmbH Rugenbergener Strasse 2a Ellerbek 25474 Hamburg Germany Tel: 00 49 4101 383073 Fax: 00 49 4101 383074 e-mail: info@hydrostopeu.com website: www.hydrostopeu.com APPROVAL INSPECTION

More information

WEDI SHOWER ELEMENTS WEDI FUNDO SHOWER ELEMENTS

WEDI SHOWER ELEMENTS WEDI FUNDO SHOWER ELEMENTS wedi Systems (UK) Ltd Unit 4 Mercury Park Mercury Way Trafford Park Manchester M41 7LY Tel: 0161 864 2336 Fax: 0161 864 1323 e-mail: info@wedi.co.uk website: www.wedi.co.uk APPROVAL INSPECTION TESTING

More information

Agrément Certificate 08/4575 website: Product Sheet 1

Agrément Certificate   08/4575 website:  Product Sheet 1 Specialist Tiling Supplies Unit 5 Wortley Trading Estate Wortley Moor Lane Leeds West Yorkshire LS12 4HX Tel: 0113 202 2010 Fax: 0113 301 0212 Agrément Certificate e-mail: info@specialisttilingsupplies.com

More information

XYPEX ADMIX C-1000 NF Additif pour béton imperméable Beimischung zur Beton Wasserdichtung. Regulations

XYPEX ADMIX C-1000 NF Additif pour béton imperméable Beimischung zur Beton Wasserdichtung. Regulations Fullstop Technology Limited Caidan House Canal Road Timperley Cheshire WA14 1TE Tel: 0161-962 8093 Fax: 0161-905 1436 e-mail: xypexfullstop@aol.com website: www.xypex.com CI/SfB Yu2 Agrément Certificate

More information

Agrément Certificate 12/4912 website: Product Sheet 2 JUTA GAS-RESISTANT MEMBRANE JUTA GP2 GAS BARRIER

Agrément Certificate   12/4912 website:  Product Sheet 2 JUTA GAS-RESISTANT MEMBRANE JUTA GP2 GAS BARRIER Juta a.s. Dukelska 417 544 15 Dvur Kralove n.l Czech Republic Tel: 00 42 0499 314211 Fax: 00 42 0499 314210 Agrément Certificate e-mail: juta@juta.cz 12/4912 website: www.juta.cz Product Sheet 2 This Agrément

More information

SAINT-GOBAIN ISOVER CAVITY WALL INSULATION WALLTHERM(2) CAVITY WALL INSULATION

SAINT-GOBAIN ISOVER CAVITY WALL INSULATION WALLTHERM(2) CAVITY WALL INSULATION Saint-Gobain Isover UK East Leake Loughborough Leicestershire LE12 6JQ Tel: 0115 9451000 Fax: 0115 9451154 e-mail: isover.enquiries@saint-gobain.com website: www.isover.co.uk APPROVAL INSPECTION TESTING

More information

Cementaid (UK) Limited 2 Rutherford Way Industrial Estate Crawley West Sussex RH10 9LN Tel: Fax: website:

Cementaid (UK) Limited 2 Rutherford Way Industrial Estate Crawley West Sussex RH10 9LN Tel: Fax: website: CI/SfB Designated by Government to issue European Technical Approvals Product Cementaid (UK) Limited 2 Rutherford Way Industrial Estate Crawley West Sussex RH10 9LN Tel: 01293 447878 Fax: 01293 447880

More information

KINGSPAN THERMAFLOOR TF73 Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden

KINGSPAN THERMAFLOOR TF73 Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden Designated by Government to issue European Technical Approvals Product Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info.uk@insulation.kingspan.com

More information

PITTSBURGH CORNING (UK) PERINSUL HL PERINSUL HL

PITTSBURGH CORNING (UK) PERINSUL HL PERINSUL HL Pittsburgh Corning (UK) Ltd 31-35 Kirby Street Hatton Garden London EC1N 8TE Tel: 020 7492 1731 Fax: 020 7492 1730 e-mail: info@foamglas.co.uk website: www.foamglas.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

KOMPOZITOR CHIMNEY SYSTEMS FURANFLEX-RWV CHIMNEY LINING SYSTEM

KOMPOZITOR CHIMNEY SYSTEMS FURANFLEX-RWV CHIMNEY LINING SYSTEM Kompozitor Plastics Development Ltd Széchenyi út 60 Vecsés 2220 Hungary Tel: +36 29 554 600 Fax: +36 29 554 610 e-mail: info@kompozitor.hu website: www.furanflex.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

Agrément Certificate 07/4420 website: Product Sheet 2

Agrément Certificate    07/4420 website:  Product Sheet 2 Mercury Building Products Ltd 114 Eckington Road Coal Aston Dronfield Sheffield S18 3AY Tel: 01246 292816 Fax: 01246 292867 Agrément Certificate e-mail: sales@vapfree.co.uk; danny@vaprfree.co.uk 07/4420

More information

MONARFLOOR ACOUSTIC SYSTEMS MONAFLOOR 9, 18 AND 22 ACOUSTIC DECK SYSTEMS

MONARFLOOR ACOUSTIC SYSTEMS MONAFLOOR 9, 18 AND 22 ACOUSTIC DECK SYSTEMS Icopal Ltd Barton Dock Road Stretford Manchester M32 0YL Tel: 0161-854 4444 Fax: 0161-864 2616 e-mail: acoustics.technical.uk@icopal.com website: www.monarfloor.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

K-SCREED FLOOR SCREEDS PRODUCT SHEET 1 STANDARD K-SCREED

K-SCREED FLOOR SCREEDS PRODUCT SHEET 1 STANDARD K-SCREED Flowcrete UK Ltd The Flooring Technology Centre Booth Lane Moston, Sandbach Cheshire CW11 3QF Tel: 01270 753000 Fax: 01270 753333 e-mail: uk@flowcrete.com website: www.flowcrete.com Agrément Certificate

More information

RECTICEL INSULATION EUROTHANE LIQUID ROOFING INSULATION BOARD

RECTICEL INSULATION EUROTHANE LIQUID ROOFING INSULATION BOARD Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke on Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung CI/SfB Designated by Government to issue European Technical Approvals Product Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info@insulation.kingspan.com

More information

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE Capital Valley Plastics Ltd Cwmavon Works Cwmavon Nr Pontypool Gwent NP4 8UW Tel: 01495 772255 Fax: 01495 772251 e-mail: sales@capitalvalleyplastics.com website: www.capitalvalleyplastics.com APPROVAL

More information

Date of Ninth issue: 27 February 2015 John Albon Claire Curtis-Thomas

Date of Ninth issue: 27 February 2015 John Albon Claire Curtis-Thomas Don & Low Ltd Nonwovens Glamis Road Forfar Angus DD8 1EY Tel: 01307 452600 Fax: 01307 452610 e-mail: nonwovens@donlow.co.uk website: www.donlow.co.uk Agrément Certificate 96/3220 Product Sheet 1 DON &

More information

XYPEX WATERTIGHT CONCRETE SYSTEM XYPEX ADMIX C-1000 NF

XYPEX WATERTIGHT CONCRETE SYSTEM XYPEX ADMIX C-1000 NF Xypex (UK) LLP Unit 7 Britannia Business Centre Britannia Way Malvern Worcestershire WR14 1GZ Tel: 01684 577756 Fax: 01684 897750 e-mail: adamtrow@xypexuk.com website: www.xypex.com APPROVAL INSPECTION

More information

PRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS)

PRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS) CI/SfB Yu2 Kryton International Inc 1645 East Kent Avenue Vancouver British Columbia Canada V5P 2S8 Tel: 00 1 604 324 8280 Fax: 00 1 604 324 8899 e-mail: info@kryton.com website: www.kryton.com Agrément

More information

HAPAS Certificate 18/H276 website: Product Sheet 1

HAPAS Certificate   18/H276 website:  Product Sheet 1 Reinforced Earth Company Ltd Innovation House Euston Way, Town Centre Telford Shropshire TF3 4LT Tel: 01952 201901 Fax: 01952 201753 HAPAS Certificate e-mail: info@reinforcedearth.co.uk 18/H276 website:

More information

ARGETON CLADDING SYSTEMS ARGETON TERRACOTTA RAINSCREEN CLADDING SYSTEM

ARGETON CLADDING SYSTEMS ARGETON TERRACOTTA RAINSCREEN CLADDING SYSTEM Telling Architectural Limited 7 The Dell Enterprise Drive Four Ashes Wolverhampton West Midlands WV10 7DF Tel: 01902 797700 Fax: 01902 797720 e-mail: info@telling.co.uk website: www.telling.co.uk APPROVAL

More information

XTRATHERM THIN-R INSULATION XTRATHERM THIN-R FLAT ROOF INSULATION BOARD (FR ALU)

XTRATHERM THIN-R INSULATION XTRATHERM THIN-R FLAT ROOF INSULATION BOARD (FR ALU) Xtratherm UK Ltd Park Road Holmewood Industrial Park Holmewood Chesterfield Tel: 0371 222 1033 Fax: 0371 222 1044 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

ROCKWOOL BUILT IN CAVITY WALL INSULATION BATTS ROCKWOOL CAVITY WALL BATT

ROCKWOOL BUILT IN CAVITY WALL INSULATION BATTS ROCKWOOL CAVITY WALL BATT Rockwool Ltd Pencoed Bridgend CF35 6NY Tel: 01656 862621 Fax: 01656 862302 e-mail: customer.support@rockwool.co.uk website: www.rockwool.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

Agrément Certificate 08/4551 website: Product Sheet 1

Agrément Certificate   08/4551 website:  Product Sheet 1 Alucoil SA Pol Ind Bayas C/Ircio, parc R72-R77 09200 Miranda de Ebro (Burgos) Spain Tel: 00 34 947 33 33 20 Fax: 00 34 947 33 12 24 Page 1 of 10 Agrément Certificate e-mail: info@alucoil.com 08/4551 website:

More information

LINK MIDDLE EAST (LME) EARTH RETENTION AND PROTECTION SYSTEMS LME WELDED MESH GABION BOXES AND MATTRESSES

LINK MIDDLE EAST (LME) EARTH RETENTION AND PROTECTION SYSTEMS LME WELDED MESH GABION BOXES AND MATTRESSES Link Middle East Ltd P O Box 16846 Jebel Ali Dubai United Arab Emirates Tel: 00 971 4 8816750 Fax: 00 971 4 8816250 e-mail: lmedubai@emirates.net.ae website: lmewireproducts.com APPROVAL INSPECTION TESTING

More information

KINGSPAN INSULATION KOOLTHERM K15 RAINSCREEN INSULATION BOARD

KINGSPAN INSULATION KOOLTHERM K15 RAINSCREEN INSULATION BOARD Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 9LA Tel: 0870 850 8555 Fax: 0870 850 8666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com APPROVAL INSPECTION

More information

British Board of Agrément tel: Bucknalls Lane fax: Herts WD25 9BA 2015

British Board of Agrément tel: Bucknalls Lane fax: Herts WD25 9BA 2015 Don & Low Ltd Nonwovens Glamis Road Forfar Angus DD8 1EY Tel: 01307 452600 Fax: 01307 452610 e-mail: nonwovens@donlow.co.uk website: www.donlow.co.uk Agrément Certificate 99/3648 Product Sheet 1 DON &

More information

SIKA ADHESIVE SYSTEM

SIKA ADHESIVE SYSTEM Sika Ltd Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: technical@uk.sika.com website: www.sika.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

DANOSA SINGLE-PLY ROOF WATERPROOFING MEMBRANES DANOPOL HS PVC ROOF WATERPROOFING MEMBRANES

DANOSA SINGLE-PLY ROOF WATERPROOFING MEMBRANES DANOPOL HS PVC ROOF WATERPROOFING MEMBRANES Danosa (Derivados Normalizados Asfálticos S.A) Polígono Industrial Sector 9 19290 Fontanar Guadalajara Spain Tel: 00 34 94 98 88 210 Fax: 00 34 94 98 88 223 e-mail: info@danosa.com website: www.danosa.com

More information

RESITRIX ROOF WATERPROOFING SYSTEMS

RESITRIX ROOF WATERPROOFING SYSTEMS Carlisle Construction Materials GmbH Schellerdamm 18 D-21079 Hamburg Germany Tel: 00 49 40 788 933 200 Fax: 00 49 40 788 933 201 e-mail: info@ccm-europe.com website: www.ccm-europe.com APPROVAL INSPECTION

More information

KINGSPAN KOOLTHERM RANGE FOR FLOORS, WALLS AND PITCHED ROOFS KOOLTHERM K8

KINGSPAN KOOLTHERM RANGE FOR FLOORS, WALLS AND PITCHED ROOFS KOOLTHERM K8 Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info@kingspaninsulation.co.uk website: www.kingspaninsulation.co.uk APPROVAL INSPECTION

More information

Agrément Certificate 16/5333 website: Product Sheet 1

Agrément Certificate   16/5333 website:  Product Sheet 1 Icopal Limited Barton Dock Road Stretford Manchester M32 0YL Tel: 0161 865 4444 Fax: 0161 866 9859 (Marketing) 0161 865 8433 (Technical) Agrément Certificate e-mail: info.uk@icopal.com 16/5333 website:

More information

Vandex (UK) Ltd P O Box 200 Guildford Surrey GU2 4WD Tel: Fax: website:

Vandex (UK) Ltd P O Box 200 Guildford Surrey GU2 4WD Tel: Fax: website: Vandex (UK) Ltd P O Box 200 Guildford Surrey GU2 4WD Tel: 0870 241 6264 Fax: 0870 241 6274 e-mail: info@vandex.co.uk website: www.vandex.co.uk CI/SfB Vq4 Agrément Certificate No 04/4188 Designated by Government

More information

Date of Second issue: 6 May 2010 Chris Hunt Greg Cooper

Date of Second issue: 6 May 2010 Chris Hunt Greg Cooper Domestic and General Insulation Ltd Energy House Magnis Works Roman Road Hereford HR4 9QR Tel: 0844 543 0043 Fax: 01432 268680 e-mail: headoffice@dgi.org.uk website: www.dgi.org.uk APPROVAL INSPECTION

More information

Agrément Certificate 13/5069 website: Product Sheet 1

Agrément Certificate   13/5069 website:  Product Sheet 1 British Polythene Limited t/a Visqueen Building Products Heanor Gate Derbyshire DE75 7RG Tel: 0333 202 6800 Fax: 0333 202 6886 Page 1 of 9 Agrément Certificate e-mail: enquiries@visqueenbuilding.co.uk

More information

PURUS DRAINAGE PRODUCTS PURUS FLOOR GULLIES

PURUS DRAINAGE PRODUCTS PURUS FLOOR GULLIES PURUS AB Södra Dragongatan 15 SE-271 39 Ystad Sweden Tel: +46 10 41 44 900 Fax: +46 10 41 44 996 e-mail: info@purus.se web: www.purus.se/en-gb APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

XTRATHERM XTROLINER (XO) XTRATHERM XTROLINER RAINSCREEN BOARD (XO/RS)

XTRATHERM XTROLINER (XO) XTRATHERM XTROLINER RAINSCREEN BOARD (XO/RS) Xtratherm Ltd Liscarton Industrial Estate Kells Road Navan Co Meath Ireland Tel: 00 353 46 906 6000 Fax: 00 353 46 906 6090 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING

More information

ECOTHERM ECO RANGE FOR FLOORS, WALLS AND PITCHED ROOFS ECOTHERM ECO-CAVITY

ECOTHERM ECO RANGE FOR FLOORS, WALLS AND PITCHED ROOFS ECOTHERM ECO-CAVITY EcoTherm Insulation (UK) Ltd Burnt Mills Industrial Estate Harvey Road Basildon Essex SS13 1QJ Tel: 01702 520166 Fax: 01702 420636 e-mail: info@ecotherm.co.uk website: www.ecotherm.co.uk APPROVAL INSPECTION

More information

DANOSA SINGLE-PLY ROOF WATERPROOFING MEMBRANES DANOPOL FV PVC ROOF WATERPROOFING MEMBRANES

DANOSA SINGLE-PLY ROOF WATERPROOFING MEMBRANES DANOPOL FV PVC ROOF WATERPROOFING MEMBRANES Danosa (Derivados Normalizados Asfálticos S.A) Polígono Industrial Sector 9 19290 Fontanar Guadalajara Spain Tel: 00 34 94 98 88 210 Fax: 00 34 94 98 88 223 e-mail: info@danosa.com website: www.danosa.com

More information

DECOTHANE ROOF COATING SYSTEMS DECOTHANE GAMMA 20 ROOF COATING SYSTEM

DECOTHANE ROOF COATING SYSTEMS DECOTHANE GAMMA 20 ROOF COATING SYSTEM Sika Liquid Plastics Sika House Miller Street Preston Lancashire PR1 1EA Tel: 01772 259781 Fax: 01772 255670 e-mail: liquidplastics@uk.sika.com website: www.liquidplastics.co.uk APPROVAL INSPECTION TESTING

More information

JABLITE FULL FILL CAVITY WALL INSULATION JABFILL PREMIUM

JABLITE FULL FILL CAVITY WALL INSULATION JABFILL PREMIUM APPROVAL INSPECTION TESTING CERTIFICATION Jablite Limited Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9100 Fax: 020 8320 9110 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate

More information

CARLISLE SYNTEC SYSTEMS PRODUCT SHEET 1 CARLISLE SURESEAL NON-REINFORCED EPDM ROOF WATERPROOFING SYSTEMS

CARLISLE SYNTEC SYSTEMS PRODUCT SHEET 1 CARLISLE SURESEAL NON-REINFORCED EPDM ROOF WATERPROOFING SYSTEMS CI/SfB (47) Ln Carlisle Syntec Incorporated 104 High Street Tetsworth Oxfordshire OX9 7AE Tel: 01844 281643 Fax: 01844 281597 e-mail: enquires@carlisleroofing.co.uk website: www.carlisle-syntec.com Agrément

More information

URSA PARTIAL AND FULL FILL CAVITY WALL INSULATION URSA CAVITY BATT 32 INSULATION

URSA PARTIAL AND FULL FILL CAVITY WALL INSULATION URSA CAVITY BATT 32 INSULATION URSA UK Ltd Crest House 102-104 Church Road Teddington Middlesex TW11 8PY Tel: 0208 977 9697 Fax: 0208 977 9456 e-mail: ursauk@ursa.com website: www.ursa-uk.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

Regulations Detail Sheet 1

Regulations Detail Sheet 1 Fakro Sp. z.o.o. ul. We,gierska 144a 33 300 Nowy Sa,cz Poland Tel: 00 18 48 444 0444 Fax: 00 18 48 444 0333 CI/SfB (37.4) Xn6 Agrément Certificate No 02/3944 Second issue* Designated by Government to issue

More information

SPRINGVALE CAVITY WALL INSULATION ECOBEAD PLATINUM CAVITY WALL INSULATION

SPRINGVALE CAVITY WALL INSULATION ECOBEAD PLATINUM CAVITY WALL INSULATION Springvale EPS Ltd Dinting Vale Business Park Glossop Derbyshire SK13 6LG Tel: 01457 863 211 Fax: 01457 869 269 e-mail: sales@springvale.com website: www.springvale.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

POLYROOF GRP ROOFING POLYROOF 185 AND POLYROOF 185 NON-SLIP ROOF WATERPROOFING SYSTEMS

POLYROOF GRP ROOFING POLYROOF 185 AND POLYROOF 185 NON-SLIP ROOF WATERPROOFING SYSTEMS Polyroof Products Ltd Furness House Castle Park Industrial Estate Flint Flintshire CH6 5XA Tel: 01352 735135 Fax: 01352 735182 e-mail: info@polyroof.co.uk website: www.polyroof.co.uk APPROVAL INSPECTION

More information

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM KVT Dichtungssysteme GmbH Rugenbergener Strasse 2a Ellerbek 25474 Hamburg Germany Tel: 00 49 4101 383073 Fax: 00 49 4101 383074 e-mail: info@hydrostopeu.com website: www.hydrostopeu.com APPROVAL INSPECTION

More information

FORTRAC GEOSYNTHETICS FORTRAC T AND R-T GEOGRIDS

FORTRAC GEOSYNTHETICS FORTRAC T AND R-T GEOGRIDS APPROVAL INSPECTION TESTING CERTIFICATION Huesker Synthetic GmbH Fabrikstrasse 13 15 D-48712 Gescher Germany Tel: 00 49 2542 7010 Fax: 00 49 2542 701499 TECHNICAL APPROVALS FOR CONSTRUCTION Roads and Bridges

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal

More information

XTRATHERM THIN-R INSULATION XTRATHERM XT/TL THERMAL LINER DRY LINING SYSTEM

XTRATHERM THIN-R INSULATION XTRATHERM XT/TL THERMAL LINER DRY LINING SYSTEM Xtratherm Limited Kells Road Navan Co Meath, Ireland Tel: 00 353 46 9066000 Fax: 00 353 46 9066090 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

PUDLO CWP (CEMENT WATERPROOFING POWDER)

PUDLO CWP (CEMENT WATERPROOFING POWDER) David Ball Group plc Huntingdon Road Bar Hill Cambridge CB3 8HN Tel: 01954 780687 Fax: 01954 782912 e-mail: sales@pudlo.com website: www.davidballgroup.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

PAVACLAD SYSTEM ISOLAIR AND PAVATHERM-PLUS WOOD FIBRE INSULATION BOARDS

PAVACLAD SYSTEM ISOLAIR AND PAVATHERM-PLUS WOOD FIBRE INSULATION BOARDS Natural Building Technologies The Hangar Worminghall Road Oakley Buckinghamshire HP18 9UL Tel: 01844 338338 Fax: 01844 338525 e-mail: info@natural-building.co.uk website: www.natural-building.co.uk PAVACLAD

More information

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

WOLFIN POLYMERIC ROOF WATERPROOFING SYSTEMS TECTOFIN RV ROOF WATERPROOFING MEMBRANES

WOLFIN POLYMERIC ROOF WATERPROOFING SYSTEMS TECTOFIN RV ROOF WATERPROOFING MEMBRANES WOLFIN Bautechnik GmbH Am Rosengarten 5 D-63607 Wächtersbach Neudorf Germany Tel: 00 49 6053 708 0 Fax: 00 49 6053 708 130 e-mail: service@wolfin.com website: www.wolfin.com APPROVAL INSPECTION TESTING

More information

VISQUEEN WATERPROOFING MEMBRANES VISQUEEN GAS RESISTANT SELF ADHESIVE MEMBRANE

VISQUEEN WATERPROOFING MEMBRANES VISQUEEN GAS RESISTANT SELF ADHESIVE MEMBRANE Visqueen Building Products Heanor Gate Heanor Derbyshire DE75 7RG Tel: 0333 202 6800 Fax: 0333 202 6886 e-mail: enquiries@visqueenbuilding.co.uk website: www.visqueenbuilding.co.uk APPROVAL INSPECTION

More information