CORDEK VENTILATION VOID FORMERS VENTFORM PANELS

Size: px
Start display at page:

Download "CORDEK VENTILATION VOID FORMERS VENTFORM PANELS"

Transcription

1 APPROVAL INSPECTION TESTING CERTIFICATION Cordek Ltd Spring Copse Business Park Slinfold West Sussex RH13 0SZ Tel: Fax: TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate 12/ website: Product Sheet 1 CORDEK VENTILATION VOID FORMERS VENTFORM PANELS This Agrément Certificate Product Sheet (1) relates to Ventform Panels, a range of profiled expanded polystyrene panels for use as ventilating void formers under suspended reinforced concrete ground-floor slab and ground-bearing concrete slab constructions, to facilitate the passive ventilation of hazardous gases (eg landfill gas and radon) emanating from the ground beneath the building. (1) Hereinafter referred to as Certificate. CERTIFICATION INCLUDES: factors relating to compliance with Building Regulations where applicable factors relating to additional non-regulatory information where applicable independently verified technical specification assessment criteria and technical investigations design considerations installation guidance regular surveillance of production formal three-yearly review. KEY FACTORS ASSESSED Ventilation capacity when used in conjunction with an appropriate gas-resistant membrane and adequate vents to the outside of the building, the panels will facilitate the effective passive ventilation of hazardous gases emanating from the ground beneath the building subject to the ventilation capacity limits given in section 6. Structural performance the panels have adequate strength to resist short-term construction phase load loading and long-term loads transmitted from the floor construction without undue deformation (see section 7). Thermal performance the panels can contribute towards achieving the design U values specified in the national Building Regulation requirements for a building (see section 8). Durability the long-term durability of the panels has been assessed and is adequate for the design life of the building (see section 10). The BBA has awarded this Certificate to the company named above for the products described herein. These products have been assessed by the BBA as being fit for their intended use provided they are installed, used and maintained as set out in this Certificate. On behalf of the British Board of Agrément Date of Second issue: 8 December 2016 Brian Chamberlain Claire Curtis-Thomas Originally certificated on 31 May 2012 Head of Technical Excellence Chief Executive The BBA is a UKAS accredited certification body Number 113. The schedule of the current scope of accreditation for product certification is available in pdf format via the UKAS link on the BBA website at Readers are advised to check the validity and latest issue number of this Agrément Certificate by either referring to the BBA website or contacting the BBA direct. British Board of Agrément Bucknalls Lane Watford Herts WD25 9BA 2016 Page 1 of 9 tel: fax: clientservices@bba.star.co.uk

2 Regulations In the opinion of the BBA, Ventform Panels, if installed, used and maintained in accordance with this Certificate, can satisfy or contribute to satisfying the relevant requirements of the following Building Regulations (the presence of a UK map indicates that the subject is related to the Building Regulations in the region or regions of the UK depicted): The Building Regulations 2010 (England and Wales) Requirement: A1(1) Loading Floors incorporating the products can be designed to sustain and transmit dead and imposed floor loads to the ground. See section 7 of this Certificate. Requirement: C1(2) Preparation of site and resistance to contaminants The products, used in conjunction with an appropriate gas-retardant membrane, can contribute to a floor structure satisfying this Requirement. See section 6 of this Certificate. Regulation: L1(a)(i) Conservation of fuel and power When used with additional layers of insulation, the products can contribute to meeting this Requirement. See section 8 of this Certificate. Regulation: 7 Materials and workmanship The products are acceptable. See section 10 and the Installation part of this Certificate. The Building (Scotland) Regulations 2004 (as amended) Regulation: 8(1)(2) Durability, workmanship and fitness of materials The products can contribute to a construction meeting this Regulation. See section 10 and the Installation part of this Certificate. Regulation: 9 Building standards applicable to construction Standard: 1.1 Structure The products contribute to meeting the relevant requirements of this Standard with reference to clause (1)(2). See section 7 of this Certificate. Standard: 3.1 Site preparation harmful and dangerous substances Standard: 3.2 Site preparation protection from radon gas The products, used in conjunction with an appropriate gas-retardant membrane, can contribute to a floor structure satisfying these Standards with reference to clauses (1)(2) and (1)(2) respectively. See section 6 of this Certificate. Standard: 6.2 Building Envelope When used with additional insulating layers, the products can contribute to satisfying the requirements of this Standard, with reference to clauses (1)(2) to (1)(2). See section 8 of this Certificate. Standard: 7.1(a)(b) Statement of sustainability The products can contribute to meeting the relevant requirements of Regulation 9, Standards 1 to 6 and therefore will contribute to a construction meeting a bronze level of sustainability as defined in this Standard. Regulation: 12 Building standards applicable to conversions All comments given for the products under Regulation 9, Standards 1 to 6 also apply to this Regulation, with reference to clause (1)(2) and Schedule 6 (1)(2). (1) Technical Handbook (Domestic). (2) Technical Handbook (Non-Domestic). The Building Regulations (Northern Ireland) 2000 (as amended) Regulation: 23(a)(b) Fitness of materials and workmanship The products are acceptable. See section 10 and the Installation part of this Certificate. Regulation: 26 Site preparation and resistance to contaminants The products, used in conjunction with an appropriate gas-retardant membrane, can contribute to a floor structure satisfying this Regulation. See section 6 of this Certificate. Regulation: Stability Floors incorporating the products can be designed to sustain and transmit dead and imposed floor loads to the ground. See section 7 of this Certificate. Regulation: 39 Conservation Measures Regulation: Target carbon dioxide Emission Rate When used with additional insulating layers, the products can contribute to satisfying the requirements of this Regulation. See section 8 of this Certificate. Construction (Design and Management) Regulations 2015 Construction (Design and Management) Regulations (Northern Ireland) 2016 Information in this Certificate may assist the client, designer (including Principal Designer) and contractor (including Principal Contractor) to address their obligations under these Regulations. See section: 3 Delivery and site handling (3.1 and 3.6) and the Installation part of this Certificate. Page 2 of 9

3 Additional Information NHBC Standards 2016 NHBC accepts the use of Ventform Panels, provided they are installed, used and maintained in accordance with this Certificate, in relation to NHBC Standards, Chapters 4.1 Land quality managing ground conditions, 5.1 Substructure and ground bearing floors and 5.2 Suspended ground floors. Technical Specification 1 Description 1.1 Ventform Panels comprise a flat polystyrene (EPS) square panel top piece of dimensions 1200 mm by 1200 mm and of either mm or 70 mm thickness, with integral EPS projections (legs) of varying profile and length beneath (see Figure 1). Figure 1 Ventform panels Ventform and Panels Ventform and 200 Panels / 70 / square legs (dimensions in mm) 120 nominal 120 nominal 2 centres ovular tapered legs (nominal width 120) 1.2 The panels are available in four different overall depths, giving different ventilation capacities and with six maximum load capacities (see Table 1). Page 3 of 9

4 Table 1 Panel characteristics Panel specification Overall depth Maximum of panel load capacity (kn m 2 ) Leg height Equivalent clear void depth (1) Ventilation capacity Nominal ventilated cross-sectional area (2) as seen in elevation (mm 2 per m width of floor) Ventform /20 Ventform / Ventform / Ventform /50 Ventform /20 Ventform / Ventform / Ventform /50 Ventform /9 Ventform /13 Ventform 200/9 Ventform 200/ (1) Equivalent clear void depth after making allowance for the panel top and the panel legs. (2) Ventilated cross sectional area available for the through-flow of air. 1.3 Ancillary items used with Ventform Panels but outside the scope of this Certificate are: gas-resistant and damp-proof membrane specification with third-party approval or equivalent air bricks and/or telescopic underfloor ventilators cavity trays. 2 Manufacture 2.1 The panels are moulded from flame-retardant grade EPS in accordance with BS EN : Different EPS grades are used to create the different load-bearing capacities. 2.2 As part of the assessment and ongoing surveillance of product quality, the BBA has: agreed with the manufacturer the quality control procedures and product testing to be undertaken assessed and agreed the quality control operated over batches of incoming materials monitored the production process and verified that it is in accordance with the documented process evaluated the process for management of nonconformities checked that equipment has been properly tested and calibrated undertaken to carry out the above measures on a regular basis through a surveillance process, to verify that the specifications and quality control operated by the manufacturer are being maintained. 2.3 The management system of Cordek Ltd has been assessed and registered as meeting the requirements of BS EN ISO 9001 : 2008 and BS EN ISO 101 : 2004 by ISOQAR (Certificate No QMS, EMS 001). 3 Delivery and site handling 3.1 The panels are delivered to site shrink-wrapped in polythene sheet in packs of 10 to 15 panels. 3.2 Each panel is embossed with the Certificate holder s name, the product name and the product specification (depth/maximum load capacity). 3.3 The panels must be protected from high winds and prolonged weathering and stored under cover to avoid prolonged exposure to sunlight. 3.4 The panels must be stored flat, on a firm, level and dry base, and be fully supported to ensure that they do not distort or bow. 3.5 Contact with solvents and organic-based materials should be avoided. 3.6 The panels must not be exposed to flame or ignition, and careful consideration should also be given to the management of fire risk when in storage. Assessment and Technical Investigations The following is a summary of the assessment and technical investigations carried out on Ventform Panels. Page 4 of 9

5 Design Considerations 4 General 4.1 Ventform Panels are satisfactory, when used in accordance with this Certificate, for use as a ventilated void former beneath suspended reinforced concrete floor slabs and ground-bearing concrete floor slabs, to facilitate the passive ventilation of hazardous gases (eg landfill gas or radon) emanating from the ground under the building. 4.2 To provide an effective gas protection system, the panels must be used with a suitable gas-resistant membrane (1) and have adequate ventilation arrangements provided through external walls of the building to allow air to enter and circulate freely through the void created by the panels (see section 6). (1) Membrane third-party Certificated. 4.3 Detailed guidance on the design and detailing of protective measures for buildings constructed on gas contaminated land is given in the national Building Regulations, BS 8485 : 2015 and the following BRE Reports: BRE Report 211 (BR 211 : 2015) Radon: Guidance on protective measures for new dwellings BRE Report 212 (BR 212 : 1991) Construction of new buildings on gas-contaminated land BRE Report (BR 376 : 1999) Radon: guidance on protective measures for new dwellings in Scotland BRE Report (BR 413 : 2001) Radon: guidance on protective measures for new dwellings in Northern Ireland BRE Report (BR 414 : 2001) Protective measures for housing on gas-contaminated land. 4.4 The panels are not designed for use in ground subject to clay heave. 5 Practicability of installation The panels are designed to be installed by a competent general builder, or a contractor, experienced with this type of product. 6 Ventilation capacity 6.1 Where subfloor ventilation is to be provided as part of the gas protection measures, the engineer responsible for the design of the building should determine the required ventilation capacity in accordance with design documents referenced in section 4.3, taking account of: the recorded concentration of the soil gas the known or likely volumetric emission rates of gas the area and shape of the slab the location of the building, the prevailing wind direction and the topography of the surrounding ground. 6.2 The appropriate panel specification should be selected with a ventilation capacity at least equal to that calculated. Equivalent clear void depth and ventilated cross-sectional area per metre width of panel are given in Table 1 for each panel specification. 6.3 The design must incorporate adequate provision in the form of air bricks, telescopic vents and other means to allow air to enter into and circulate freely within the void created by the panels. The type and location of the vents should be determined by the engineer responsible for the design of the building and should be shown on the construction drawings. Minimum vent opening sizes are given in the design guidance documents referenced in section Structural performance 7.1 For suspended, reinforced concrete floor slabs, the appropriate panel specification is selected according to the proposed finished thickness of the concrete slab. To limit the maximum anticipated compressive creep deformation of the panel to an acceptable level of 2 mm or less, the maximum uniformly distributed load (UDL) carried by the panel during the initial period (1 to 16 hours) from commencement of the concrete pour must not exceed the maximum load capacity of the panel (see Table 1). The design UDL load should include the weight of the wet concrete and an allowance for heaping of the concrete during pouring. The minimum allowance for heaping should be taken as 1.5 kn m 2, but may need to be increased depending on the methods used for placing and compacting the concrete. 7.2 For ground-bearing floor slabs, the panel specification should be selected so that it also limits the anticipated maximum long-term (50-year) compressive creep deformation to the level determined by the structural design engineer responsible for the design of the building. This will depend on the type of building and its intended use. 7.3 Anticipated 50-year compressive creep deformations and permissible design loads for each panel specification are given in Table 2. In all cases, the design load should be taken as the maximum combination of unfactored dead and imposed load likely to be transmitted to the panel, determined in accordance with BS EN 1990 : 2002 and BS EN : 2002 and their UK National Annexes. Page 5 of 9

6 Table 2 Long-term creep deformation ground-bearing long-term creep compression Panel depth Panel specification Maximum load-carrying capacity of the panel (kn m 2 ) Maximum anticipated 50-year compressive creep deformation under a design load equal to maximum load-bearing capacity of the panel (%) Maximum permissible design load to limit 50-year creep deformation to 2% (kn m 2 ) and and and and and 200 and For both suspended and ground-bearing floor slabs, the structural engineer responsible for the design of the building should confirm the adequacy of the bearing substrate to carry maximum short- and long-term design loads transmitted through the panels. 7.5 Provision should also be incorporated into the design to limit short-term concentrated loads that could cause localised damage to the panels and gas-resistant membrane (for example, under reinforcement spacers). Reinforcement spacers should be selected with large base areas and should be located at sufficiently close centres to ensure that the maximum load beneath the spacer does not exceed the maximum load-carrying capacity of the panel (see Tables 1 and 2). Where necessary, load-spreader plates should be specified beneath the reinforcement spacers. 8 Thermal performance 8.1 Depending on the panel specification selected, a typical floor construction comprising a mm concrete slab constructed above a Ventform Panel and having a p/a ratio between 0.4 and 0.9 will achieve a calculated U value between 0.27 W m 2 K 1 and 0. W m 2 K 1. Designers should allow for additional insulation as required to meet the typical design U values quoted in the documents supporting the national Building Regulations. 8.2 Calculation of specific design floor U values should be completed in accordance with BS EN ISO : 2007, BS EN ISO 6946 : 2007 and BR443 Conventions for U value calculations (2006 Edition). All floor constructions incorporating Ventform Panels should be treated as suspended. The thermal conductivity values given in Table 3 should be used for the panels. The panels may be simplified as plane boards with the effective thicknesses given in Table 3. Alternatively, detailed thermal modelling may be carried out in accordance with BS EN ISO : Table 3 Design values for use in U value calculations Ventform panel specification (panel depth/grade) /20 and /20 /9 and 200/9 / and / /13 and 200/13 / and / /50 and /50 Thermal conductivity 90/90 (W m 1 K 1 ) (1) (1) Panel effective thickness (1) For the /, /50, / and /50 panels, the thermal conductivity values quoted have been determined from available mean thermal conductivity data with an increment added as no 90/90 values were available. 8.3 Care should be taken during detailed design to avoid thermal bridging at junctions. 9 Maintenance 9.1 Once installed, the panels do not require maintenance. 9.2 To ensure effective ventilation of the void space created beneath the floor construction, airbricks and other venting devices installed in the perimeter walls of the building must be inspected at intervals and maintained free of blockage. 10 Durability The products will perform effectively as a void former for the life of the building. They are rot-proof and waterresistant, dimensionally stable under varying conditions of temperature and humidity, and unaffected by exposure to radon and methane gas. 11 Reuse and recyclability The products are made from polystyrene, which can be recycled. Page 6 of 9

7 Installation 12 General 12.1 Installation of Ventform Panels must follow the requirements of this Certificate and the Certificate holder s installation instructions. Adequate supervision must be maintained and, if required, the Certificate holder s specialists, experienced in site practice and installation of the material, will attend the site to provide demonstrations to ensure correct installation Normal precautions for handling EPS materials should be taken to avoid damaging the panels during offloading, storage, handling and installation. Any damaged panels must be replaced before pouring the concrete Protection from wind uplift may be required during installation. 13 Preparation 13.1 All loose material, eg vegetation, must be removed prior to installation of the panels Preparation and levelling of the formation must be as specified on the construction drawings prepared by the structural engineer responsible for the design of the building. This may comprise a layer of concrete blinding over a layer of hardcore, or a compactable blinding Ventilators must be installed in accordance with the construction drawings on opposite walls with sufficient air gaps in any intervening walls to ensure that no stagnant gas pockets (dead zones) exist, or are created (see Figures 2 and 3). The ventilators must be placed securely and sealed in position, and must be leak-tight Where cavity trays are specified, care should be taken to ensure continuity with the gas resistant membrane. Figure 2 Typical suspended floor slab construction gas membrane taped or welded joint FFL air brick cavity tray gas resistant dpc ground level adjustable cavity vent vent connector additional insulation (if required) Ventform concrete blinding Page 7 of 9

8 Figure 3 Typical ground-bearing floor slab construction gas membrane taped or welded joint FFL air brick cavity tray gas resistant dpc ground level adjustable cavity vent vent connector additional insulation (if required) Ventform concrete blinding 14 Procedure 14.1 The panels should be arranged to minimise the amount of cutting and re-shaping. Panels must be butted tightly together, ensuring that all gaps are minimal. Any gaps formed must be no greater than the maximum that can be bridged by the gas-resistant membrane. Where cutting is unavoidable, this can be easily completed using a fine tooth saw Once the panels have been installed, a compatible damp-proofing and gas-resistant membrane is laid over the panels with all sealing, joints and details carried out strictly in accordance with the membrane manufacturer s instructions Service entries can be accommodated by cutting the panels to ensure a tight fit. Where holes or cuts are made in the gas-resistant membrane, these must be made good using the sealing and jointing compounds and methods (eg tapes and top-hats) specified by the membrane manufacturer The membrane must be checked thoroughly for integrity by a competent person and any damaged repaired prior to concrete placement To provide protection and avoid damage during the construction phase, such as laying reinforcement and during pouring and placing of the concrete floor slabs, a suitable protective layer can be laid over the gas-resistant membrane Reinforcement spacers should be carefully selected and positioned as set out in section Trafficking across panels should be minimised, and concrete poured from a low height or concrete pumping equipment used to avoid localised impact or overloading. Technical Investigations 15 Investigations 15.1 An assessment was made of existing data to determine: long/short term creep thermal performance resistance of EPS to methane gas durability Typical U values were derived for the floor system using modelling and calculation in accordance with BS EN ISO : 2007, BS EN ISO : 2007, BS EN ISO 6946 : 2007 and BR443 Conventions for U value calculations (2006 Edition) The manufacturing process was evaluated, including the methods adopted for quality control, and details were obtained of the quality and composition of the materials used An assessment was made of the practicability of installation, including site handling. Page 8 of 9

9 Bibliography BS 8485 : 2015 Code of practice for the design of protective measures for methane and carbon dioxide ground gases for new buildings BS EN 16 : 2013 Thermal insulating products for building applications Determination of compressive creep BS EN 1990 : A1 : 2005 Eurocode Basis of structural design NA to BS EN 1990 : A1 : 2005 UK National Annex to Eurocode Basis of structural design BS EN : 2002 Eurocode 1 Actions on structures General actions NA to BS EN : 2002 UK National Annex to Eurocode 1 Actions on structures General actions BS EN ISO : 2007 Thermal bridges in building construction Heat flows and surface temperatures Detailed calculations BS EN : A1 : 2015 Thermal insulation products for buildings Factory made products of expanded polystyrene (EPS) Specification BS EN ISO 6946 : 2007 Building components and building elements Thermal resistance and thermal transmittance Calculation method BS EN ISO : 2007 Thermal performance of buildings Heat transfer via the ground Calculation methods Conditions of Certification 16 Conditions 16.1 This Certificate: relates only to the product/system that is named and described on the front page is issued only to the company, firm, organisation or person named on the front page no other company, firm, organisation or person may hold or claim that this Certificate has been issued to them is valid only within the UK has to be read, considered and used as a whole document it may be misleading and will be incomplete to be selective is copyright of the BBA is subject to English Law Publications, documents, specifications, legislation, regulations, standards and the like referenced in this Certificate are those that were current and/or deemed relevant by the BBA at the date of issue or reissue of this Certificate This Certificate will remain valid for an unlimited period provided that the product/system and its manufacture and/or fabrication, including all related and relevant parts and processes thereof: are maintained at or above the levels which have been assessed and found to be satisfactory by the BBA continue to be checked as and when deemed appropriate by the BBA under arrangements that it will determine are reviewed by the BBA as and when it considers appropriate The BBA has used due skill, care and diligence in preparing this Certificate, but no warranty is provided In issuing this Certificate, the BBA is not responsible and is excluded from any liability to any company, firm, organisation or person, for any matters arising directly or indirectly from: the presence or absence of any patent, intellectual property or similar rights subsisting in the product/system or any other product/system the right of the Certificate holder to manufacture, supply, install, maintain or market the product/system actual installations of the product/system, including their nature, design, methods, performance, workmanship and maintenance any works and constructions in which the product/system is installed, including their nature, design, methods, performance, workmanship and maintenance any loss or damage, including personal injury, howsoever caused by the product/system, including its manufacture, supply, installation, use, maintenance and removal any claims by the manufacturer relating to CE marking Any information relating to the manufacture, supply, installation, use, maintenance and removal of this product/ system which is contained or referred to in this Certificate is the minimum required to be met when the product/system is manufactured, supplied, installed, used, maintained and removed. It does not purport in any way to restate the requirements of the Health and Safety at Work etc. Act 1974, or of any other statutory, common law or other duty which may exist at the date of issue or reissue of this Certificate; nor is conformity with such information to be taken as satisfying the requirements of the 1974 Act or of any statutory, common law or other duty of care. British Board of Agrément tel: Bucknalls Lane fax: Watford clientservices@bba.star.co.uk Herts WD25 9BA Page 9 of 9

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX BONDING STRIP (GDFBS 70 AND GDFBS 110) Filon Products Limited Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 2JQ Tel: 01543 687300 Fax: 01543 687303 e-mail: sales@filon.co.uk website: www.filon.co.uk APPROVAL INSPECTION

More information

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE

RADBAR DAMP-PROOF COURSES RADBAR HIGH PERFORMANCE DAMP-PROOF COURSE Capital Valley Plastics Ltd Cwmavon Works Cwmavon Nr Pontypool Gwent NP4 8UW Tel: 01495 772255 Fax: 01495 772251 e-mail: sales@capitalvalleyplastics.com website: www.capitalvalleyplastics.com APPROVAL

More information

PITTSBURGH CORNING (UK) PERINSUL HL PERINSUL HL

PITTSBURGH CORNING (UK) PERINSUL HL PERINSUL HL Pittsburgh Corning (UK) Ltd 31-35 Kirby Street Hatton Garden London EC1N 8TE Tel: 020 7492 1731 Fax: 020 7492 1730 e-mail: info@foamglas.co.uk website: www.foamglas.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

WAVIN ROAD GULLIES. Date of First issue: 16 April 2014 Brian Chamberlain Claire Curtis-Thomas

WAVIN ROAD GULLIES. Date of First issue: 16 April 2014 Brian Chamberlain Claire Curtis-Thomas HAPAS Wavin Ltd Parsonage Way Chippenham Wiltshire SN15 5PN Tel: 01249 766600 Fax: 01249 443286 e-mail: info@wavin.co.uk website: www.wavin.co.uk WAVIN ROAD GULLIES APPROVAL INSPECTION TESTING CERTIFICATION

More information

Agrément Certificate 17/5450 website: Product Sheet 1 FOSROC HYDRO-EXPANSIVE WATERSTOPS SUPERCAST SW

Agrément Certificate   17/5450 website:  Product Sheet 1 FOSROC HYDRO-EXPANSIVE WATERSTOPS SUPERCAST SW Fosroc Limited Drayton Manor Business Park Coleshill Road Tamworth Staffordshire B78 3XN Tel: 01827 262222 Fax: 01827 262444 Agrément Certificate e-mail: enquiryuk@fosroc.com 17/5450 website: www.fosroc.com

More information

TYVEK CONSTRUCTION MEMBRANES DUPONT AIRGUARD REFLECTIVE

TYVEK CONSTRUCTION MEMBRANES DUPONT AIRGUARD REFLECTIVE DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 337660 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com APPROVAL INSPECTION

More information

FENTRIM SEALING TAPES

FENTRIM SEALING TAPES SIGA Cover AG Rütmattstrasse 7 Ruswil 6017 Switzerland Tel: 00 41 41 499 69 69 Agrément Certificate e-mail: siga@siga.swiss 16/5378 website: www.siga.swiss Product Sheet 1 SIGA AIR AND WEATHERTIGHTNESS

More information

XTRATHERM THIN-R INSULATION XTRATHERM THIN-R FLAT ROOF INSULATION BOARD (FR ALU)

XTRATHERM THIN-R INSULATION XTRATHERM THIN-R FLAT ROOF INSULATION BOARD (FR ALU) Xtratherm UK Ltd Park Road Holmewood Industrial Park Holmewood Chesterfield Tel: 0371 222 1033 Fax: 0371 222 1044 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD

PRODUCT SHEET 1 KINGSPAN KOOLTHERM K3 FLOORBOARD Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 4LA Tel: 0870 8508555 Fax: 0870 8508666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com Agrément Certificate

More information

Agrément Certificate 12/4912 website: Product Sheet 2 JUTA GAS-RESISTANT MEMBRANE JUTA GP2 GAS BARRIER

Agrément Certificate   12/4912 website:  Product Sheet 2 JUTA GAS-RESISTANT MEMBRANE JUTA GP2 GAS BARRIER Juta a.s. Dukelska 417 544 15 Dvur Kralove n.l Czech Republic Tel: 00 42 0499 314211 Fax: 00 42 0499 314210 Agrément Certificate e-mail: juta@juta.cz 12/4912 website: www.juta.cz Product Sheet 2 This Agrément

More information

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX VALLEY TROUGHS (GDFVT 70 AND GDFVT 110)

FILON GRP VALLEY TROUGH AND FLASHINGS RANGE FILON GRP DRY FIX VALLEY TROUGHS (GDFVT 70 AND GDFVT 110) Filon Products Limited Unit 3 Ring Road, Zone 2 Burntwood Business Park Burntwood Staffordshire WS7 2JQ Tel: 01543 687300 Fax: 01543 687303 e-mail: sales@filon.co.uk website: www.filon.co.uk APPROVAL INSPECTION

More information

RECTICEL INSULATION EUROTHANE LIQUID ROOFING INSULATION BOARD

RECTICEL INSULATION EUROTHANE LIQUID ROOFING INSULATION BOARD Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke on Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

BALLYTHERM INSULATION BALLYTHERM BTR PITCHED ROOF INSULATION

BALLYTHERM INSULATION BALLYTHERM BTR PITCHED ROOF INSULATION Ballytherm Ltd Annagh Industrial Park Ballyconnell Co Cavan Ireland Tel: 00 353 49 9527000 Fax: 00 353 49 9527002 e-mail: info@ballytherm.ie website: www.ballytherm.ie APPROVAL INSPECTION TESTING CERTIFICATION

More information

Agrément Certificate 13/5069 website: Product Sheet 1

Agrément Certificate   13/5069 website:  Product Sheet 1 British Polythene Limited t/a Visqueen Building Products Heanor Gate Derbyshire DE75 7RG Tel: 0333 202 6800 Fax: 0333 202 6886 Page 1 of 9 Agrément Certificate e-mail: enquiries@visqueenbuilding.co.uk

More information

BAKOR HOT-APPLIED MONOLITHIC STRUCTURAL WATERPROOFING SYSTEM BAKOR EV HOT-APPLIED MONOLITHIC MEMBRANE DAMP-PROOFING SYSTEM

BAKOR HOT-APPLIED MONOLITHIC STRUCTURAL WATERPROOFING SYSTEM BAKOR EV HOT-APPLIED MONOLITHIC MEMBRANE DAMP-PROOFING SYSTEM APPROVAL INSPECTION TESTING CERTIFICATION Bauder Ltd 70 Landseer Road Ipswich Suffolk IP3 1DH Tel: 01473 257671 Fax: 01473 230761 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate 06/4350 e-mail:

More information

CARPENTER LOFT INSULATION EASY LOFT FOR LOFT APPLICATIONS

CARPENTER LOFT INSULATION EASY LOFT FOR LOFT APPLICATIONS Carpenter Ltd Dinting Lodge Industrial Estate Glossop Derbyshire SK13 6LE Tel: 01457 861141 Fax: 01457 892424 e-mail: sales.uk@carpenter.com website: www.carpenter.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

RIW LIQUID-APPLIED WATERPROOFING SYSTEMS

RIW LIQUID-APPLIED WATERPROOFING SYSTEMS RIW Ltd Arc House Terrace Road South Binfield Bracknell Berkshire RG42 4PZ Tel: 01344 397777 Fax: 01344 862010 e-mail: technical@riw.co.uk website: www.riw.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

TIMBERWISE DAMP-PROOF SYSTEMS DRIWISE

TIMBERWISE DAMP-PROOF SYSTEMS DRIWISE Timberwise (UK) Ltd 1 Drake Mews Gadbrook Way Gadbrook Park Cheshire CW9 7XF Tel: 01606 333636 Fax: 01606 334748 e-mail: hq@timberwise.co.uk website: www.timberwise.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

JABLITE FULL FILL CAVITY WALL INSULATION JABFILL PREMIUM

JABLITE FULL FILL CAVITY WALL INSULATION JABFILL PREMIUM APPROVAL INSPECTION TESTING CERTIFICATION Jablite Limited Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9100 Fax: 020 8320 9110 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate

More information

XTRATHERM XTROLINER (XO) XTRATHERM XTROLINER RAINSCREEN BOARD (XO/RS)

XTRATHERM XTROLINER (XO) XTRATHERM XTROLINER RAINSCREEN BOARD (XO/RS) Xtratherm Ltd Liscarton Industrial Estate Kells Road Navan Co Meath Ireland Tel: 00 353 46 906 6000 Fax: 00 353 46 906 6090 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING

More information

JABLITE JABFLOOR BOARDS JABFLOOR PREMIUM 70 AND 100

JABLITE JABFLOOR BOARDS JABFLOOR PREMIUM 70 AND 100 Jablite Limited Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9100 Fax: 020 8320 9110 website: www.jablite.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION

More information

EUROTHANE GP EUROTHANE GP PITCHED ROOF INSULATION

EUROTHANE GP EUROTHANE GP PITCHED ROOF INSULATION Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke on Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

KINGSPAN KOOLTHERM RANGE FOR FLOORS, WALLS AND PITCHED ROOFS KOOLTHERM K8

KINGSPAN KOOLTHERM RANGE FOR FLOORS, WALLS AND PITCHED ROOFS KOOLTHERM K8 Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info@kingspaninsulation.co.uk website: www.kingspaninsulation.co.uk APPROVAL INSPECTION

More information

STIRLING LLOYD WATERPROOFING SYSTEMS INTEGRITANK

STIRLING LLOYD WATERPROOFING SYSTEMS INTEGRITANK Stirling Lloyd Polychem Ltd Union Bank King Street Knutsford Cheshire WA16 6EF Tel: 01565 633111 Fax: 01565 633555 e-mail: info@stirlinglloyd.com website: www.stirlinglloyd.com APPROVAL INSPECTION TESTING

More information

JABLITE EPS BLOCKS JABLITE QUICKFLOOR EPS INFILL BLOCKS

JABLITE EPS BLOCKS JABLITE QUICKFLOOR EPS INFILL BLOCKS Jablite Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9 Fax: 020 8320 9110 e-mail: sales@jablite.co.uk website: www.jablite.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK)

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK) Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

SIKA HYDROPHILIC WATERSTOPS SIKASWELL A2010

SIKA HYDROPHILIC WATERSTOPS SIKASWELL A2010 Sika Ltd Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: technical@uk.sika.com website: www.sika.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

TYVEK CONSTRUCTION MEMBRANES TYVEK REFLEX INSULATING BREATHER MEMBRANE

TYVEK CONSTRUCTION MEMBRANES TYVEK REFLEX INSULATING BREATHER MEMBRANE DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 337660 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com APPROVAL INSPECTION

More information

ECOTHERM ECO RANGE FOR FLOORS, WALLS AND PITCHED ROOFS ECOTHERM ECO-CAVITY

ECOTHERM ECO RANGE FOR FLOORS, WALLS AND PITCHED ROOFS ECOTHERM ECO-CAVITY EcoTherm Insulation (UK) Ltd Burnt Mills Industrial Estate Harvey Road Basildon Essex SS13 1QJ Tel: 01702 520166 Fax: 01702 420636 e-mail: info@ecotherm.co.uk website: www.ecotherm.co.uk APPROVAL INSPECTION

More information

ISOVER CAVITY WALL INSULATION CWS 36, CWS 34 AND CWS 32 FULL FILL CAVITY WALL SLABS

ISOVER CAVITY WALL INSULATION CWS 36, CWS 34 AND CWS 32 FULL FILL CAVITY WALL SLABS Saint Gobain Isover UK Whitehouse Industrial Estate Runcorn Cheshire WA7 3DP Tel: 0115 969 8009 Fax: 0115 945 1948 e-mail: isover.enquiries@saint-gobain.com website: www.isover.co.uk APPROVAL INSPECTION

More information

MULTIFOIL INSULATION TLX GOLD INSULATING BREATHER MEMBRANE FOR PITCHED ROOFS

MULTIFOIL INSULATION TLX GOLD INSULATING BREATHER MEMBRANE FOR PITCHED ROOFS TLX Insulation Ltd Moss Lane Blackrod Bolton Lancashire BL6 5JB Tel: 01204 695666 Fax: 01204 695333 e-mail: tlx@tlxinsulation.co.uk website: www.tlxinsulation.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

WEDI SHOWER ELEMENTS WEDI FUNDO SHOWER ELEMENTS

WEDI SHOWER ELEMENTS WEDI FUNDO SHOWER ELEMENTS wedi Systems (UK) Ltd Unit 4 Mercury Park Mercury Way Trafford Park Manchester M41 7LY Tel: 0161 864 2336 Fax: 0161 864 1323 e-mail: info@wedi.co.uk website: www.wedi.co.uk APPROVAL INSPECTION TESTING

More information

PURUS DRAINAGE PRODUCTS PURUS FLOOR GULLIES

PURUS DRAINAGE PRODUCTS PURUS FLOOR GULLIES PURUS AB Södra Dragongatan 15 SE-271 39 Ystad Sweden Tel: +46 10 41 44 900 Fax: +46 10 41 44 996 e-mail: info@purus.se web: www.purus.se/en-gb APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

VITRABOND RAINSCREEN CLADDING SYSTEMS VITRABOND FR ALUMINIUM COMPOSITE RAINSCREEN CLADDING PANELS

VITRABOND RAINSCREEN CLADDING SYSTEMS VITRABOND FR ALUMINIUM COMPOSITE RAINSCREEN CLADDING PANELS Valcan Ltd APPROVAL INSPECTION TESTING CERTIFICATION Unit 7 Robins Drive Castlefields Industrial Estate Bridgwater Somerset TA6 4DL Tel: 01278 428 245 Fax: 01278 425 662 TECHNICAL APPROVALS FOR CONSTRUCTION

More information

KOMPOZITOR CHIMNEY SYSTEMS FURANFLEX-RWV CHIMNEY LINING SYSTEM

KOMPOZITOR CHIMNEY SYSTEMS FURANFLEX-RWV CHIMNEY LINING SYSTEM Kompozitor Plastics Development Ltd Széchenyi út 60 Vecsés 2220 Hungary Tel: +36 29 554 600 Fax: +36 29 554 610 e-mail: info@kompozitor.hu website: www.furanflex.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

VISQUEEN WATERPROOFING MEMBRANES VISQUEEN GAS RESISTANT SELF ADHESIVE MEMBRANE

VISQUEEN WATERPROOFING MEMBRANES VISQUEEN GAS RESISTANT SELF ADHESIVE MEMBRANE Visqueen Building Products Heanor Gate Heanor Derbyshire DE75 7RG Tel: 0333 202 6800 Fax: 0333 202 6886 e-mail: enquiries@visqueenbuilding.co.uk website: www.visqueenbuilding.co.uk APPROVAL INSPECTION

More information

THERMABLOK AEROGEL LTD THERMAL INSULATION SYSTEMS THERMABLOK AEROGEL THERMASLIM INTERNAL WALL INSULATION SYSTEMS

THERMABLOK AEROGEL LTD THERMAL INSULATION SYSTEMS THERMABLOK AEROGEL THERMASLIM INTERNAL WALL INSULATION SYSTEMS Intelligent Insulation Ltd The Oasts Church Farm Estates Ulcombe Kent ME17 1DN Tel: 01622 840289 Fax: 0844 7792242 e-mail: info@thermablok.co.uk website: www.thermablok.co.uk APPROVAL INSPECTION TESTING

More information

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN WARM NON-VENTILATED PITCHED ROOF SYSTEMS

PERMO AIR LR AIR OPEN ROOFING MEMBRANE FOR USE IN WARM NON-VENTILATED PITCHED ROOF SYSTEMS Klober Ltd Unit 6F, East Midlands Distribution Centre Short Lane Castle Donington Derbyshire DE74 2HA Tel: 01332 813050 Fax: 01332 814033 e-mail: support@klober.co.uk website: www.klober.co.uk APPROVAL

More information

URSA PARTIAL AND FULL FILL CAVITY WALL INSULATION URSA CAVITY BATT 32 INSULATION

URSA PARTIAL AND FULL FILL CAVITY WALL INSULATION URSA CAVITY BATT 32 INSULATION URSA UK Ltd Crest House 102-104 Church Road Teddington Middlesex TW11 8PY Tel: 0208 977 9697 Fax: 0208 977 9456 e-mail: ursauk@ursa.com website: www.ursa-uk.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR EXTERNAL WALLS

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR EXTERNAL WALLS Demilec Inc. 2925 Galleria Drive Arlington Texas 76011 USA Tel: + 011-817-640-4900 Fax: + 011-817-663-2000 e-mail: info@demilecusa.com website: www.demilecusa.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

SPRINGVALE FLOORING INSULATION FOR CONCRETE GROUND FLOORS

SPRINGVALE FLOORING INSULATION FOR CONCRETE GROUND FLOORS Springvale EPS Ltd Dinting Vale Business Park Dinting Vale Glossop Derbyshire SK13 6LG Tel: 01457 863211 Fax: 01457 869269 e-mail: sales@springvale.com website: www.springvale.com APPROVAL INSPECTION TESTING

More information

KINGSPAN THERMAFLOOR TF73 Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden

KINGSPAN THERMAFLOOR TF73 Isolation en polystyrène pour planchers en béton Wärmedämmung aus Polystyrol für Betonfußboden Designated by Government to issue European Technical Approvals Product Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info.uk@insulation.kingspan.com

More information

Agrément Certificate 08/4575 website: Product Sheet 1

Agrément Certificate   08/4575 website:  Product Sheet 1 Specialist Tiling Supplies Unit 5 Wortley Trading Estate Wortley Moor Lane Leeds West Yorkshire LS12 4HX Tel: 0113 202 2010 Fax: 0113 301 0212 Agrément Certificate e-mail: info@specialisttilingsupplies.com

More information

CABERDEK. Date of First issue: 28 November 2008 Simon Wroe Greg Cooper

CABERDEK. Date of First issue: 28 November 2008 Simon Wroe Greg Cooper Norbord Ltd Station Road Cowie Stirling FK7 7BQ Tel: 01786 812921 Fax: 01786 817143 e-mail: info@norbord.net website: www.norbord.net APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION

More information

SIKA ADHESIVE SYSTEM

SIKA ADHESIVE SYSTEM Sika Ltd Watchmead Welwyn Garden City Hertfordshire AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: technical@uk.sika.com website: www.sika.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

RECTICEL INSULATION RECTICEL EUROWALL +

RECTICEL INSULATION RECTICEL EUROWALL + Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke on Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

SPRINGVALE CAVITY WALL INSULATION ECOBEAD PLATINUM CAVITY WALL INSULATION

SPRINGVALE CAVITY WALL INSULATION ECOBEAD PLATINUM CAVITY WALL INSULATION Springvale EPS Ltd Dinting Vale Business Park Glossop Derbyshire SK13 6LG Tel: 01457 863 211 Fax: 01457 869 269 e-mail: sales@springvale.com website: www.springvale.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

GENERAL MEMBRANE ROOF WATERPROOFING MEMBRANES PHOENIX STAR AND PHOENIX STAR MINERAL ROOF WATERPROOFING MEMBRANES

GENERAL MEMBRANE ROOF WATERPROOFING MEMBRANES PHOENIX STAR AND PHOENIX STAR MINERAL ROOF WATERPROOFING MEMBRANES General Membrane SpA Via Venezia 28 30022 Ceggia (VE) Italy Tel: 00 39 0421 322000 Fax: 00 39 0421 322800 e-mail: info@generalmembrane.it website: generalmembrane.it APPROVAL INSPECTION TESTING CERTIFICATION

More information

Agrément Certificate 17/5420 Product Sheet 1 ULTRA LIQUID POLYMERS ROOF WATERPROOFING SYSTEMS

Agrément Certificate   17/5420 Product Sheet 1 ULTRA LIQUID POLYMERS ROOF WATERPROOFING SYSTEMS Ultra Liquid Polymers Ltd 39 Everton Road Birkdale Merseyside PR8 4BT Tel: +44 (0) 3304 004457 Fax: +44 (0) 3304 004458 Agrément Certificate e-mail: info@ultra-polymers.com 17/5420 Product Sheet 1 ULTRA

More information

EUROTHANE GP. Date of Second issue: 17 October 2013 John Albon Head of Approvals Claire Curtis-Thomas

EUROTHANE GP. Date of Second issue: 17 October 2013 John Albon Head of Approvals Claire Curtis-Thomas Recticel Insulation Products (a division of Recticel Ltd) Enterprise Way Meir Park Stoke-on-Trent Staffordshire ST3 7UN Tel: 01782 590470 Fax: 01782 590497 e-mail: technicalservices@recticel.com website:

More information

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM KVT Dichtungssysteme GmbH Rugenbergener Strasse 2a Ellerbek 25474 Hamburg Germany Tel: 00 49 4101 383073 Fax: 00 49 4101 383074 e-mail: info@hydrostopeu.com website: www.hydrostopeu.com APPROVAL INSPECTION

More information

MAX FRANK EGCOBOX CANTILEVER CONNECTION SYSTEM EGCOBOX CANTILEVER CONNECTION SYSTEM

MAX FRANK EGCOBOX CANTILEVER CONNECTION SYSTEM EGCOBOX CANTILEVER CONNECTION SYSTEM Max Frank Ltd Whittle Road Meir Stoke on Trent Staffordshire ST3 7HF Tel: 01782 598041 email: info@maxfrank.co.uk website: www.maxfrank.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

KINGSPAN THERMAROOF TR21

KINGSPAN THERMAROOF TR21 CI/SfB Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 0870 8508555 Fax: 0870 8508666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com (47) Rn Agrément

More information

JABLITE FLAT ROOF INSULATION ROOF BOARDS JABLITE INVERTED ROOF INSULATION HIGH PERFORMANCE (HP)

JABLITE FLAT ROOF INSULATION ROOF BOARDS JABLITE INVERTED ROOF INSULATION HIGH PERFORMANCE (HP) APPROVAL INSPECTION TESTING CERTIFICATION Jablite Limited Infinity House Anderson Way Belvedere Kent DA17 6BG Tel: 020 8320 9100 Fax: 020 8320 9110 TECHNICAL APPROVALS FOR CONSTRUCTION Agrément Certificate

More information

Agrément Certificate 08/4551 website: Product Sheet 1

Agrément Certificate   08/4551 website:  Product Sheet 1 Alucoil SA Pol Ind Bayas C/Ircio, parc R72-R77 09200 Miranda de Ebro (Burgos) Spain Tel: 00 34 947 33 33 20 Fax: 00 34 947 33 12 24 Page 1 of 10 Agrément Certificate e-mail: info@alucoil.com 08/4551 website:

More information

KINGSPAN NILVENT ROOF TILE UNDERLAYS FOR USE IN WARM NON-VENTILATED OR COLD VENTILATED ROOF SYSTEMS

KINGSPAN NILVENT ROOF TILE UNDERLAYS FOR USE IN WARM NON-VENTILATED OR COLD VENTILATED ROOF SYSTEMS Kingspan Insulation Ltd Torvale Industrial Estate Pembridge, Leominster Herefordshire HR6 9LA Tel: 0870 850 8555 Fax: 0870 850 8666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com

More information

KINGSPAN INSULATION KOOLTHERM K15 RAINSCREEN INSULATION BOARD

KINGSPAN INSULATION KOOLTHERM K15 RAINSCREEN INSULATION BOARD Kingspan Insulation Ltd Pembridge Leominster Herefordshire HR6 9LA Tel: 0870 850 8555 Fax: 0870 850 8666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com APPROVAL INSPECTION

More information

PERMAROOF 500 LIQUID ROOF SYSTEM

PERMAROOF 500 LIQUID ROOF SYSTEM Permaroof UK Ltd Unit 1, Westway Cotes Park Industrial Estate Alfreton Derbyshire DE55 4QJ Tel: 0800 161 3722 Fax: 01773 608 408 Agrément Certificate e-mail: sales@permaroof.co.uk 16/5372 website: www.permaroof.co.uk

More information

TRUSTSEAL HIGH-FRICTION SURFACING SYSTEM KEYGRIP EPOXY 924

TRUSTSEAL HIGH-FRICTION SURFACING SYSTEM KEYGRIP EPOXY 924 HAPAS Roads and Bridges Trustseal Ltd Unit 10 Southfield Industrial Estate Southfield Lane Whitwell, Worksop Nottinghamshire S80 4NW Tel: 01909 722662 Fax: 01909 720228 e-mail: info@trustseal.co.uk website:

More information

SPRINGVALE FLOORING SYSTEMS SPRINGVALE BEAMSHIELD PLUS AND PLATINUM BEAMSHIELD PLUS EPS BLOCKS

SPRINGVALE FLOORING SYSTEMS SPRINGVALE BEAMSHIELD PLUS AND PLATINUM BEAMSHIELD PLUS EPS BLOCKS Springvale EPS Ltd Dinting Vale Glossop Derbyshire SK13 6LG Tel: 0845 769 7452 (Technical Advisory Service) e-mail: technical@springvale.com website: www.springvale.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK)

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK) Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung CI/SfB Designated by Government to issue European Technical Approvals Product Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 01544 388601 Fax: 01544 388888 e-mail: info@insulation.kingspan.com

More information

XTRATHERM THIN-R INSULATION XTRATHERM XT/TL THERMAL LINER DRY LINING SYSTEM

XTRATHERM THIN-R INSULATION XTRATHERM XT/TL THERMAL LINER DRY LINING SYSTEM Xtratherm Limited Kells Road Navan Co Meath, Ireland Tel: 00 353 46 9066000 Fax: 00 353 46 9066090 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

XYPEX WATERTIGHT CONCRETE SYSTEM XYPEX ADMIX C-1000 NF

XYPEX WATERTIGHT CONCRETE SYSTEM XYPEX ADMIX C-1000 NF Xypex (UK) LLP Unit 7 Britannia Business Centre Britannia Way Malvern Worcestershire WR14 1GZ Tel: 01684 577756 Fax: 01684 897750 e-mail: adamtrow@xypexuk.com website: www.xypex.com APPROVAL INSPECTION

More information

H + H AIRCRETE BLOCKS AND THIN-JOINT SYSTEM H + H THIN-JOINT SYSTEM

H + H AIRCRETE BLOCKS AND THIN-JOINT SYSTEM H + H THIN-JOINT SYSTEM H + H UK Ltd Celcon House Ightham Sevenoaks Kent TN15 9HZ Tel: 01732 886333 Fax: 01732 886810 e-mail: marketing@hhcelcon.co.uk website: www.hhcelcon.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

PUDLO CWP (CEMENT WATERPROOFING POWDER)

PUDLO CWP (CEMENT WATERPROOFING POWDER) David Ball Group plc Huntingdon Road Bar Hill Cambridge CB3 8HN Tel: 01954 780687 Fax: 01954 782912 e-mail: sales@pudlo.com website: www.davidballgroup.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Agrément Certificate 07/4420 website: Product Sheet 2

Agrément Certificate    07/4420 website:  Product Sheet 2 Mercury Building Products Ltd 114 Eckington Road Coal Aston Dronfield Sheffield S18 3AY Tel: 01246 292816 Fax: 01246 292867 Agrément Certificate e-mail: sales@vapfree.co.uk; danny@vaprfree.co.uk 07/4420

More information

THERMALITE AIRCRETE BLOCKS AND THIN-JOINT SYSTEM THERMALITE THIN-JOINT SYSTEM

THERMALITE AIRCRETE BLOCKS AND THIN-JOINT SYSTEM THERMALITE THIN-JOINT SYSTEM Forterra Building Products Limited 5 Grange Park Court Roman Way Northampton NN4 5EA Tel: 0330 123 1018 Fax: 01530 273183 e-mail: asktechnical@forterra.co.uk website: www.forterra.co.uk APPROVAL INSPECTION

More information

RESITRIX ROOF WATERPROOFING SYSTEMS RESITRIX SK W WATERPROOFING SYSTEM

RESITRIX ROOF WATERPROOFING SYSTEMS RESITRIX SK W WATERPROOFING SYSTEM Phoenix Dichtungstechnik GmbH Eisenacher Landstrasse 70 D-99880 Walterhaussen Germany Tel: 00 49 40 7667 2807 Fax: 00 49 40 7667 2949 website: www.pdt-waterproofing.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

PRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS)

PRODUCT SHEET 1 KRYSTOL INTERNAL MEMBRANE HS (KIM-HS) CI/SfB Yu2 Kryton International Inc 1645 East Kent Avenue Vancouver British Columbia Canada V5P 2S8 Tel: 00 1 604 324 8280 Fax: 00 1 604 324 8899 e-mail: info@kryton.com website: www.kryton.com Agrément

More information

DANOSA SINGLE-PLY ROOF WATERPROOFING MEMBRANES DANOPOL FV PVC ROOF WATERPROOFING MEMBRANES

DANOSA SINGLE-PLY ROOF WATERPROOFING MEMBRANES DANOPOL FV PVC ROOF WATERPROOFING MEMBRANES Danosa (Derivados Normalizados Asfálticos S.A) Polígono Industrial Sector 9 19290 Fontanar Guadalajara Spain Tel: 00 34 94 98 88 210 Fax: 00 34 94 98 88 223 e-mail: info@danosa.com website: www.danosa.com

More information

BAUDER PIR INSULATION BAUDER PIR ROOF INSULATION BOARDS

BAUDER PIR INSULATION BAUDER PIR ROOF INSULATION BOARDS Bauder Ltd 70 Landseer Road Ipswich Suffolk IP3 0DH Tel: 01473 257671 Fax: 01473 230761 e-mail: info@bauder.co.uk website: www.bauder.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

Date of Second issue: 6 May 2010 Chris Hunt Greg Cooper

Date of Second issue: 6 May 2010 Chris Hunt Greg Cooper Domestic and General Insulation Ltd Energy House Magnis Works Roman Road Hereford HR4 9QR Tel: 0844 543 0043 Fax: 01432 268680 e-mail: headoffice@dgi.org.uk website: www.dgi.org.uk APPROVAL INSPECTION

More information

RESITRIX ROOF WATERPROOFING SYSTEMS

RESITRIX ROOF WATERPROOFING SYSTEMS Carlisle Construction Materials GmbH Schellerdamm 18 D-21079 Hamburg Germany Tel: 00 49 40 788 933 200 Fax: 00 49 40 788 933 201 e-mail: info@ccm-europe.com website: www.ccm-europe.com APPROVAL INSPECTION

More information

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR PITCHED ROOFS AND LOFT SPACES

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR PITCHED ROOFS AND LOFT SPACES Demilec Inc. 2925 Galleria Drive Arlington Texas 76011 USA Tel: + 011-817-640-4900 Fax: + 011-817-663-2000 e-mail: info@demilecusa.com website: www.demilecusa.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

SAINT-GOBAIN ISOVER CAVITY WALL INSULATION WALLTHERM(2) CAVITY WALL INSULATION

SAINT-GOBAIN ISOVER CAVITY WALL INSULATION WALLTHERM(2) CAVITY WALL INSULATION Saint-Gobain Isover UK East Leake Loughborough Leicestershire LE12 6JQ Tel: 0115 9451000 Fax: 0115 9451154 e-mail: isover.enquiries@saint-gobain.com website: www.isover.co.uk APPROVAL INSPECTION TESTING

More information

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC Lapolla Industries, Inc 15402 Vantage Parkway East, Suite 322 Houston Texas 77032 USA Tel: + 001 877 636 2648 e-mail: info@lapolla.com website: www.lapolla.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

MULTIFOIL INSULATION PRODUCT SHEET 1 THINSULEX SILVER

MULTIFOIL INSULATION PRODUCT SHEET 1 THINSULEX SILVER CI/SfB Lh4 (M2) Web Dynamics Ltd Moss Lane Blackrod Bolton Lancashire BL6 5JB Tel: 01204 695666 Fax: 01204 695333 e-mail: thinsulex@webdynamics.co.uk website: www.webdynamics.co.uk Agrément Certificate

More information

TECHNICAL DATA SHEET CIVILS & INFRASTRUCTURE CLAY HEAVE PROTECTION

TECHNICAL DATA SHEET CIVILS & INFRASTRUCTURE CLAY HEAVE PROTECTION Claymaster Building Substructure - Below ground clay heave protection Claymaster is an EPS compressible-fill material used to reduce the pressure against foundations due to clay heave. Supplied coloured

More information

GRAF STORMWATER MANAGEMENT SYSTEMS GRAF INFILTRATION TUNNEL SYSTEM

GRAF STORMWATER MANAGEMENT SYSTEMS GRAF INFILTRATION TUNNEL SYSTEM GRAF UK Ltd Target House Thorpe Way Industrial Estate Banbury Oxfordshire OX16 4SP Tel: 01608 661500 e-mail: info@grafuk.co.uk website: www.grafuk.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM

HYDROSTOPEU LIQUID APPLIED ROOF WATERPROOFING SYSTEMS AH 25 LIQUID WATERPROOFING SYSTEM KVT Dichtungssysteme GmbH Rugenbergener Strasse 2a Ellerbek 25474 Hamburg Germany Tel: 00 49 4101 383073 Fax: 00 49 4101 383074 e-mail: info@hydrostopeu.com website: www.hydrostopeu.com APPROVAL INSPECTION

More information

ICYNENE INSULATION H 2 FOAMLITE

ICYNENE INSULATION H 2 FOAMLITE Icynene Inc 6747 Campobello Road Mississauga Ontario L5N 2L7 Canada Tel: 00 1 905 363 4040 Fax: 00 1 905 363 0102 e-mail: info@icynene.com website: www.icynene.com APPROVAL INSPECTION TESTING CERTIFICATION

More information

Agrément Certificate 16/5333 website: Product Sheet 1

Agrément Certificate   16/5333 website:  Product Sheet 1 Icopal Limited Barton Dock Road Stretford Manchester M32 0YL Tel: 0161 865 4444 Fax: 0161 866 9859 (Marketing) 0161 865 8433 (Technical) Agrément Certificate e-mail: info.uk@icopal.com 16/5333 website:

More information

DELTA MEMBRANE SYSTEMS DELTA-MS500

DELTA MEMBRANE SYSTEMS DELTA-MS500 Delta Membrane Systems Ltd Delta House Merlin Way North Weald, Epping Essex CM16 6HR Tel: 01992 523523 Fax: 01992 523250 e-mail: info@deltamembranes.com website: www.deltamembranes.com APPROVAL INSPECTION

More information

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm

BEAM & BLOCK SYSTEM. 108mm. 175mm Deep (160mm) Wide Beam. 160mm RH F RACKHAM HOUSEFLOORS BEAM & BLOCK SYSTEM BEAM & BLOCK SYSTEM 1. THE BEAMS 60mm 108mm 90mm 75mm 75mm 100mm 175mm 100mm 175mm 125mm 100mm 175mm Deep Beam 175mm Deep (160mm) Wide Beam 225mm Deep Beam

More information

CEMBRIT SLATES ZEELAND SLATES

CEMBRIT SLATES ZEELAND SLATES Cembrit a.s. Lidická 302 266 38 Beroun 3 Czech Republic Tel: 00 420 311 744111 Fax: 00 420 311 744248 e-mail: info@cembrit.cz website: www.cembrit.cz APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

SIKA WATERPROOFING SYSTEMS SIKA-1 WATERPROOFING SYSTEMS

SIKA WATERPROOFING SYSTEMS SIKA-1 WATERPROOFING SYSTEMS Sika Ltd Watchmead Welwyn Garden City Herts AL7 1BQ Tel: 01707 394444 Fax: 01707 329129 e-mail: waterproofing@uk.sika.com website: www.sika.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 2 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN ENERGY EFFICIENT COLD NON-VENTILATED ROOFS

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 2 TYVEK SUPRO ROOF TILE UNDERLAY FOR USE IN ENERGY EFFICIENT COLD NON-VENTILATED ROOFS DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com Agrément Certificate

More information

DECOTHANE ROOF COATING SYSTEMS DECOTHANE GAMMA 20 ROOF COATING SYSTEM

DECOTHANE ROOF COATING SYSTEMS DECOTHANE GAMMA 20 ROOF COATING SYSTEM Sika Liquid Plastics Sika House Miller Street Preston Lancashire PR1 1EA Tel: 01772 259781 Fax: 01772 255670 e-mail: liquidplastics@uk.sika.com website: www.liquidplastics.co.uk APPROVAL INSPECTION TESTING

More information

DELTA MEMBRANE SYSTEMS DELTA-PT

DELTA MEMBRANE SYSTEMS DELTA-PT Delta Membrane Systems Ltd Unit 7 Bassett Business Centre Hurricane Way North Weald, Epping Essex CM16 6AA Tel: 01992 523811 Fax: 01992 524046 e-mail: info@deltamembranes.com website: www.deltamembranes.com

More information

Dow Building Solutions. Insulating floors with STYROFOAM Solutions: basic principles

Dow Building Solutions. Insulating floors with STYROFOAM Solutions: basic principles Dow Building Solutions Insulating floors with STYROFOAM Solutions: basic principles Introduction STYROFOAM -A Dow Building Solutions STYROFOAM -A products include FLOORMATE -A materials for flooring applications.

More information

Garage Conversion - Between and Under Joist Applications

Garage Conversion - Between and Under Joist Applications Issue 1, August 2013 CI/SfB (2 -) Rn7 (M2) Garage Conversion - Between and Under Joist Applications Flat Roof Insulation Introduction Celotex is the brand leading manufacturer of PIR insulation boards,

More information

FATRA ROOF COVERING SYSTEMS FATRAFOL FF 810 AND FATRAFOL FF 810/V ROOF COVERING SYSTEMS

FATRA ROOF COVERING SYSTEMS FATRAFOL FF 810 AND FATRAFOL FF 810/V ROOF COVERING SYSTEMS Fatra UK Ltd Unit 12 The Timber Yard East Moors Road Ocean Park Cardiff CF24 5EE Tel: 029 2048 7954 Fax: 029 2048 9226 e-mail: sales@fatra.co.uk website: www.fatra.co.uk APPROVAL INSPECTION TESTING CERTIFICATION

More information

Building Regulations

Building Regulations Product 1.1 Technobond is a range of polyester fibre insulation used as thermal and acoustic insulating material in ceilings, roofs and walls of buildings. Appraisal No.69 [010] BRANZ Appraisals Technical

More information

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings I n s u l a t i o n CI/Sfb (23.9) Rn7 M2 First Issue September 2012 INSULATION FOR FLOORS High performance thermal insulation Suitable for installation in all weather conditions Suitable for use above

More information

ROGER BULLIVANT LIMITED SYSTEMFIRST HOUSE FOUNDATION SYSTEM

ROGER BULLIVANT LIMITED SYSTEMFIRST HOUSE FOUNDATION SYSTEM Roger Bullivant Limited Walton Road Drakelow Burton-on-Trent Staffordshire DE15 9UA Tel: 01283 511115 Fax: 01283 543395 e-mail: design@roger-bullivant.co.uk website: www.roger-bullivant.co.uk APPROVAL

More information

XYPEX ADMIX C-1000 NF Additif pour béton imperméable Beimischung zur Beton Wasserdichtung. Regulations

XYPEX ADMIX C-1000 NF Additif pour béton imperméable Beimischung zur Beton Wasserdichtung. Regulations Fullstop Technology Limited Caidan House Canal Road Timperley Cheshire WA14 1TE Tel: 0161-962 8093 Fax: 0161-905 1436 e-mail: xypexfullstop@aol.com website: www.xypex.com CI/SfB Yu2 Agrément Certificate

More information

ALUPANEL XT WORKING PRACTISE. For any projects where Alupanel XT or Alupanel XTFR are considered for any building cladding.

ALUPANEL XT WORKING PRACTISE. For any projects where Alupanel XT or Alupanel XTFR are considered for any building cladding. ALUPANEL XT WORKING PRACTISE For any projects where Alupanel XT or Alupanel XTFR are considered for any building cladding. Before we are able to supply a quotation for the supply of this material, we require

More information

CHAPTER 3: Modern Methods of Construction (MMC)

CHAPTER 3: Modern Methods of Construction (MMC) CONTENTS 3.1.1 INTRODUCTION 3.1.2 SUITABILITY OF SYSTEMS AND COMPONENTS 3.1.3 TYPES OF MODERN METHODS OF CONSTRUCTION (MMC) 3.1.4 SUITABILITY OF SYSTEMS TO MEET WARRANTY REQUIREMENTS 3.1.5 INSULATED CONCRETE

More information