Applications of sustainable post-tensioned concrete slabs

Size: px
Start display at page:

Download "Applications of sustainable post-tensioned concrete slabs"

Transcription

1 Innov. Infrastruct. Solut. (2017) 2:42 DOI /s TECHNICAL PAPER Applications of sustainable post-tensioned concrete slabs Amr A. Abdelrahman 1 Received: 4 May 2017 / Accepted: 2 June 2017 / Published online: 7 July 2017 Ó Springer International Publishing AG 2017 Abstract Post-tensioning is used for the last decades for different concrete elements such as slabs, beams, walls and mat foundations. For industrial and office buildings with large spans, application of post-tensioned, (PT), concrete floors is competitive to reinforced concrete. Use of PT slabs results in small sections, better serviceability, durable structures and faster construction compared to reinforced concrete construction. In some cases, it demonstrates an economic alternative to conventional concrete or steel floors. Post-tensioning concrete slabs are applied using either bonded or unbonded tendons. Bonded tendons is achieved by grouting the ducts containing the steel tendons after stressing. Consequently, the prestressing force is transmitted to the concrete by bond along the steel tendons. In unbonded tendons applications, the ducts are left after stressing without grouting and the force is transmitted at the anchorages of the prestressing steel. This paper introduces analysis, design and construction techniques of PT concrete floors. Computer model specifically made to design PT slabs satisfying the requirements of the code is introduced. Case studies carried out in Egypt and in the Gulf area in the last few years with particular application of post-tensioning are also introduced. These case studies include buildings of spans up to 24.0 ms, as well as water tank of 100,000 m 3 capacity. Recommendations and design guidelines of PT concrete slabs as well as the assessment of the current Egyptian code are highlighted. This paper was selected from GeoMEast 2017 Sustainable Civil Infrastructures: Innovative Infrastructure Geotechnology. & Amr A. Abdelrahman amr_abdelrahman@eng.asu.edu.eg 1 Concrete Structures and Chair of the Structural Engineering Department, Ain Shams University, Abasia, Cairo, Egypt Keywords Application Computer model Design Posttensioning Prestressed concrete Slabs Introduction Post-tensioned (PT) concrete floors are used on a large scale in residential and office buildings in North America, Europe, Fareast and Gulf area. Compared to conventional reinforced concrete (RC) floors, PT slabs provide less thickness, fast construction cycle for each floor, durable concrete and, consequently, cost-effective structure. Posttensioning utilizes high-quality high strength steel such that 1 kg of post-tensioning strand may replace 3 or 4 kg of ordinary non-prestressed reinforcement [1]. This can reduce congestion of steel reinforcement in concrete members. In Egypt, PT floors are not used on the same scale as in other countries, which may be attributed to the fact that until year 2001 there was no design code for prestressed concrete. However, it should be mentioned that research in prestressed concrete started in Egypt as early as in 1959 [2]. The edition of the Egyptian Code for Design and Construction of Reinforced Concrete Structures ECP [3] addresses design and constructional details of prestressed concrete elements. Post-tensioned slabs are constructed using either bonded or unbonded prestressing tendons. Bonded tendons can be achieved by grouting the ducts containing the steel tendons after stressing. Therefore, the prestressing force is transmitted to the concrete by bond along the prestressing steel reinforcement. This introduces compatibility between the prestressing steel and concrete, which means that after bonding any strain experienced by the concrete is experienced by the prestressing steel and vice versa. In unbonded tendons applications, the ducts are left after stressing

2 42 Page 2 of 12 Innov. Infrastruct. Solut. (2017) 2:42 without grouting and the force is transmitted at the anchorages of the reinforcement. This means that bond is deliberately prevented along the length of the tendon. Thus, concrete strains are not translated directly into similar strains in the prestressing steel. Corrosion protection of the unbonded prestressing steel should be carefully applied to improve the durability of the concrete. Failure of unbonded steel strands at the anchorage zone was monitored as a result of steel corrosion. This paper introduces analysis and design technique of PT floors according to ECP [3] and other current international codes [4, 5]. Computer model specifically made to calculate the prestressing forces, losses and stresses and to design statically indeterminate PT concrete members is presented. The paper also presents case studies constructed in Egypt and in the Gulf area with PT floors. The first case study is an office building consisting of two basements, ground, three typical floors and roof, which was completed in The typical floor has an area of 3200 m 2 with spacing between columns of 10.8 and 5.4 m in both directions. Posttensioned flat slab with thickness of 250 mm was used. The second case is an exhibition hall constructed in 2003 of two floors, 2400 m 2 per floor. The maximum spacing between columns is 17.0 and 16.0 m in the two directions. The floor is constructed using PT main and secondary beams and oneway RC slabs on the top. Another case study is presented where the typical floor has a distribution of the columns with the largest panel of m. The floor is constructed with post-tensioned ribbed slab of 600 mm depth. The last case study is water tank, where the slab-on-ground was prestressed to minimize the dimension and the amount of used steel. Assessment of different design aspects of PT concrete members according to the current Egyptian [3] code with comparison to the ACI [4] and British [5] codes is also introduced. Different design recommendations and construction details are given. Analysis of post-tensioned flat slabs Thickness of PT flat slabs is chosen as span/40 to 50 with span/45 as most commonly used value for two-way flat slabs and span/40 for one way slabs [6]. Different analytical techniques are recommended by design codes [3 5] for post-tensioned flat slabs including finite element method and equivalent frame analysis method, which is similar to that used for RC flat plates. In the frame analysis method, the relative stiffness between columns and slabs should be taken into consideration. Distribution of the bending moments between the column and field s is carried out according to the percentages given by the code. A computer code was specifically made using visual basic and Spreadsheet MS Excel to perform the analysis of PT statically indeterminate concrete members, as shown in Fig. 1. The computer code is linked to a structural analysis program SAP2000 to calculate the straining actions in the members due to gravity, horizontal and prestressing loads. The computer code can also perform the design of PT members under service and ultimate loading conditions. The code applies the equivalent frame method as a design tool of PT slabs. It also calculates the losses of prestressing forces and serviceability limit states of PT members. Finally, it generates the eccentricities of the cable profile and links it with a drawing program AutoCAD for implementation in the drawings. The following discusses the analysis and design aspects of PT concrete slabs. Cable pattern Different cable layout may be used in flat slabs depending on the percentage of the prestressing steel in the column and field s, as shown in Fig. 2. Prestressing steel in the column may vary from 50 to 100% out of the total amount of steel. Steel layout shown in Fig. 2a represents 100% of the prestressing steel banded through columns in both directions, while the middle part of the slab is reinforced by normal steel reinforcement. Figure 2b represents 100% of the prestressing steel banded through columns in one direction and uniformly distributed in the other direction. 75% of the prestressing steel may be concentrated in the column s and 25% in the field s in both directions, as in Fig. 2c, or only in one direction and uniformly distributed in the other direction as in Fig. 2d. Choice of the cable layout depends on the dimensions of the concrete panel as well as on different constructibility aspects of the PT flat slab. For example in Fig. 2c, d, elevation of the cables in the x-direction should top the cables in the y-direction at certain locations and laid under the cables at other locations to achieve the designed eccentricity of the prestressing tendons. This certainly will complicate the process of laying out the cables. The most common cable pattern is shown in Fig. 2b, where cables in the y-direction are laid out first according to the designed profile and topped with the cables in the x-direction. For flat slabs with aspect ratio more than 1.5, the distributed tendons are laid out in the long direction and tendons in the short direction are concentrated above the columns, as shown in Fig. 2b. In that case, the slab will act as a one-way slab in the long direction supported on embedded beams in the short direction. Cable profile Profile of the prestressing tendons should be carefully selected to optimize the number of steel strands. Figure 3 shows the general profile of a tendon in one panel. Three curves are used to characterize the profile using a parabolic shape described by the expression given in Eq. 1 for each

3 Innov. Infrastruct. Solut. (2017) 2:42 Page 3 of Fig. 1 Computer code solving the cable profile curve. Length of curves 1 and 3 jjl is determined to satisfy the minimum radius R of the prestressing cables. The value of jj shown in Fig. 3 is typically taken between 0.05 and 0.1. y i ¼ a i x 2 i þ b i x i þ c i ð1þ where y i and x i are the eccentricity and distance of the tendon of the curve i, respectively. a i, b i and c i are constants. i = 1, 2 or 3. Constraints defining the cable profile are given for the curves in Eqs Based on the selected concrete cover and thickness of the ducts, the eccentricities at sections Introduction, Design of PT floors and Conclusions are assumed (Eqs. 2, 3, 4). Concrete cover is selected to satisfy both the fire rating and durability of the building. The eccentricity and tangent of curves 1 and 2 at point 2 should be the same (Eqs. 5, 7), and of curves 2 and 3 at point 4 should also be the same (Eqs. 6, 8). The tangent of curves 1 and 3 at points 1 and 5 is assumed to be zero (Eqs. 9, 10). An iteration process is carried out to solve Eqs and the constants a, b and c given in Eq. 1 are determined for the three curves to describe the cable profile along the given span. Figure 1 shows the computer code established to describe the cable profile. y 1 ¼ e 1 ðfor curve 1Þ ð2þ y 3 ¼ e 3 ðfor curve 2Þ ð3þ y 5 ¼ e 5 ðfor curve 3Þ ð4þ y 2 ðfor curve 1Þ ¼ y 2 ðfor curve 2Þ ð5þ y 4 ðfor curve 2Þ ¼ y 4 ðfor curve 3Þ ð6þ dy dx dy dx dy dx dy dx for curve 1 ¼ 2 for curve 2 ¼ 3 ¼ 0 ðfor curve 1Þ 1 ¼ 0 ðfor curve 3Þ 5 Structural analysis dy dx dy dx for curve 2 2 for curve 3 4 ð7þ ð8þ ð9þ ð10þ The structure is divided into a series of frames in the x and y directions and solved to calculate the straining actions taking into consideration effect of prestressing

4 42 Page 4 of 12 Innov. Infrastruct. Solut. (2017) 2:42 Fig. 2 Cable pattern normal reinforcement tendons (a) 100% banded through columns in both directions and normal reinforcement (b) 100% banded through columns in one direction and uniform distribution in other direction middle column middle middle column middle (c) 75% concentrated in column and 25% in middle in both directions middle column middle (d) 75% concentrated in column and 25% in middle in one direction-other direction uniform Fig. 3 Cable profile e 5 e e 3 1 R Curve (1) Curve (2) Curve (3) column βl (1-2β) L βl L forces. The computer code shown in Fig. 1 generates the required data of prestressing forces and eccentricities of the cables to be linked to a structural analysis program using FEM SAP2000. Effect of the prestressing force on the supporting elements is considered in the analysis. For high column stiffness, it is expected that a large bending moment due to prestressing is transferred to the columns; in addition, less prestressing force is transferred to the slabs. These forces will change by time due to creep of concrete and losses in the prestressing force. In some cases, the concrete area of the slab around the stiff columns or shear walls is cast after stressing the columns to reduce the losses in the prestressing force. More deformation is expected for the flexible columns and, consequently, larger axial force in the slabs due to prestressing.

5 Innov. Infrastruct. Solut. (2017) 2:42 Page 5 of Design of PT floors Post-tensioned floors should be designed to satisfy allowable stresses in the concrete under service loading condition. Ultimate limit state of flexure, shear (one-way or punching shear) should be checked using factored loads. Serviceability limit states in terms of camber, deflection and vibration should also be checked. In addition, crack width and fatigue of prestressed and non-prestressed steel should be calculated in case of partial prestressing. The previously described computer code was extended for the design of statically indeterminate PT elements including service and ultimate limit states. The computer code can solve any number of continuous spans and calculate the prestress losses, service stresses and required additional non-prestressing steel. Service stresses in concrete A major difference exists between design codes since the Egyptian code [3] does not allow partial prestressing; i.e., no cracks are allowed in the prestressed concrete members under service loading. It is the author s understanding that partial prestressing was not allowed in the code since it is only the first edition for prestressed concrete code in Egypt and it will be included in the coming issue. In the ACI code [4], partial prestressing is not allowed in prestressed twoway slabs but allowed in all other members. The British Standards [5] allows three classes for prestressed members; class 1 where no tensile stresses are allowed, class 2 where tensile stresses are still below the rupture strength of concrete and class 3 where concrete sections are allowed to crack. The difference in the allowable values of concrete stresses under initial and final loading conditions is minor in the three design codes. Ultimate limit state of flexure One of the most crucial issues in the design of statically indeterminate prestressed members is the effect of secondary moment (M r ) on the ultimate limit state of flexure. The secondary moment is the moment resulting from the reactions induced by prestressing forces, and can be calculated as the difference between the moment due to prestressing (M f ) minus the primary moment (M o ) resulting from the product of the prestressing force and eccentricity of the cable, as given in Eq. 11. M r ¼ M f M o ð11þ The secondary moment is significant in both the elastic and inelastic states. The elastic deformations caused by a non-concordant tendon change the amount of inelastic rotation required to obtain a given amount of moment redistribution. Conversely, for a member with a given inelastic rotational capacity, the amount by which the moment at the support may be varied is changed by an amount equal to the secondary moment at the support due to prestressing. Therefore, the secondary moments should be included in determining design moments [7]. The ACI code states that moments used to compute required strength shall be the sum of the secondary moments (with a load factor of 1.0) and the moments due to factored loads. The ACI also permits to increase or decrease negative moments calculated by elastic theory for any assumed loading, where bonded reinforcement is provided at supports. It shall be permitted to increase or decrease negative moments calculated by elastic theory at supports of continuous flexural members for any assumed loading arrangement by not more than 1000 jj t %, with a maximum of 20%. Redistribution of negative moments shall be made only when jj t is equal to or greater than at the section at which moment is reduced. jj t is the net tensile strain in extreme tension steel at nominal strength excluding the strains due to effective prestress, creep, shrinkage, and temperature. The commentary of the ACI code states, When hinges and full redistribution of moments occur to create a statically determinate structure, secondary moments disappear. Bondy [7] introduced an analytical approach to show that the secondary moments do not disappear at any load level. The Egyptian code ECP does not address the effect of secondary moment on the ultimate limit state of flexure. Ultimate limit state of shear Both one-way and two-way (punching) shear of PT flat slabs should be checked using limit state design. Prestressing has a marked increase on the resistance of concrete sections to shear forces. The ACI and British codes permit the use of shear reinforcement in the slabs in the form of bars or wires and single- or multiple-leg stirrups in slabs. The Egyptian code ECP addresses oneway and two-way shear for prestressed members. The code does not also allow use of steel reinforcement to resist punching shear stresses in the slabs. Serviceability limit states Both camber and deflection of fully prestressed members are calculated based on the gross moment of inertia. However, for partially prestressed members the inertia should be reduced to account for cracks. The ACI code recommends the bi-linear moment-deflection relationship or an effective moment of inertia (I e ) method to calculate the deflection. The British code recommends using the

6 42 Page 6 of 12 Innov. Infrastruct. Solut. (2017) 2:42 Moment curvature curve for deflection calculation of partially prestressed members. Case studies Case studies are presented in this paper. The first case study is an office building, where PT flat slab was used with banded tendons in one direction and distributed tendons in the other. The second study is an exhibition hall with a limited clear height and large spans between the columns. PT main and secondary beams were used to cover the accessible slabs. Considerable savings in cost and time were achieved in the construction of the two structures. In the third case study, a larger panel of dimensions m was constructed using post-tensioned ribbed slab with 600 mm depth. The last case is a water tank with overall dimensions m in plan. The slabon-ground with thickness of 300/600 mm was post-tensioned in both directions. First case study The first case study is an office building, which consists of two basements, ground, three typical floors and a roof. The typical floor has an area of 3200 m 2 with spacing between columns of 10.8 and 5.4 m in both directions. The building was divided into three parts by two expansion joints, as shown in Figs. 4 and 5. The structural design of the floors in the tender document included one-way ribbed slab and embedded RC beams. The contractor was challenged to finish the project in 9 months and was faced by an unexpected increase in the price of steel reinforcement. Posttensioned flat slab with thickness of 250 mm was proposed to substitute the RC slab. RC beams were used on the Fig. 4 Plan of the 1st case study Fig. 5 Aerial view of the 1st case study outside perimeter of the building to maintain the architectural appearance of the façade. The project was completed on time with considerable savings in the cost of floor slabs. Construction details Selection of the cable pattern was based on the rectangularity of the slabs. A total of five banded prestressing steel tendons were located in the short direction; i.e., in the direction of 5.40 m spans between columns. Distributed tendons every 1.35 m were placed in the long direction of the slab, as shown in Fig. 6. Four and three prestressing steel strands of 15 mm diameter were used in the banded and distributed tendons, respectively. The prestressing steel conformed to the ASTM A416 with tensile strength and strain of 1860 MPa and 3.5%, respectively. The strands were placed in galvanized steel ducts with overall dimensions of mm. Steel bars of 10 mm diameter were PART PART 1 PART x 5.4 = 43.2

7 Innov. Infrastruct. Solut. (2017) 2:42 Page 7 of Fig. 6 Details of the prestressing steel Fig. 9 Dead end free edge regions not prestressed in direction parallel to tendons banded tendons Fig. 7 Profiling of the steel tendons Fig. 10 Non-prestressed regions in slabs Fig. 8 Jacking end Fig. 11 Casting concrete slabs

8 42 Page 8 of 12 Innov. Infrastruct. Solut. (2017) 2:42 Fig. 12 Structural plan of the exhibition hall 13.6 Main beam secondary beams Main beam Fig. 13 Overview of the floor slab before casting concrete used as chairs with varying heights to shape the profile of the tendons, as shown in Fig. 7. The jacking and dead ends of the prestressing steel tendons are shown in Figs. 8 and 9, respectively. Special reinforcement was used around the end blocks to resist the splitting tensile stresses induced from the prestressing forces. Additional non-prestressed steel was used on top of the columns to ensure enough flexural capacity at ultimate loads. Unlike the distributed tendons, the banded tendons induce compressive stresses that are not uniform on the edge of the slab, as shown in Fig. 10. Additional nonprestressed steel reinforcement of 10 mm diameter every 160 mm was placed perpendicular to the free edge in the non-prestressed zones. Concrete with characteristic cube strength of 40 MPa after 28 days was used to cast the slabs, as shown in Fig. 11. Curing compound was applied on the concrete surface directly after casting to minimize the tensile stresses due to shrinkage. Fig. 14 Details of the intersection between main and secondary beams Fig. 15 View of the case study number 3 After the concrete had reached 30 MPa, which was normally achieved in 3 days, the steel strands were tensioned to 75% of its ultimate tensile strength. Elongations of the strands were measured and compared to the calculated values. Once the prestressing forces were applied, the

9 Innov. Infrastruct. Solut. (2017) 2:42 Page 9 of formwork was removed and assembled for the next floor. Ducts containing the prestressing steel strands were grouted with a flowable mix with 40 MPa compressive strength. Construction cycle of each part of the floor slab took only 7 days. Second case study The second case study is an exhibition hall constructed of two floors with an area of 2400 m 2 per floor. The maximum spacing between columns is 17.0 and 16.0 m in the two directions, as shown in Fig. 12. Maximum thickness of floors was selected to maintain the clear height given by the architect. Due to the limited height of floors, RC frames were not a structural alternative. Two structural systems of the floor slabs were studied. The first system was composite steel beams and concrete slabs and the second was post-tensioned main and secondary beams with one-way RC slab on top. The second system was selected due to its cost effectiveness and durability. Two four-span continuous main beams were used to support a group of secondary beams. The main beams were Fig. 16 a Plan of the typical PT concrete floor with banded tendons. b Plan of the typical PT concrete floor with distributed tendons (a) (b)

10 42 Page 10 of 12 Innov. Infrastruct. Solut. (2017) 2: m apart, while the secondary beams were spaced every 3.0 m. Post-tensioned beams were designed to be fully prestressed tensile stresses under service loading according to the ECP Ultimate limit states of flexure and shear were checked and additional reinforcement was placed at the columns and mid-spans. Constructional details The main beams were 1500 mm wide and 1100 mm deep, while the secondary beams had a varying width of mm and a depth of 700 mm. The varying width of the secondary beams was mainly to allow for the extra reinforcement placed at the end blocks of the prestressing forces. The one-way RC slab used on top was 160 mm thick. Five prestressing steel cables with 12 steel strands per one were used to prestress each main beam. Ducts used in the main beams were circular of 90 mm diameter. Two prestressing steel cables of eight steel strands per each were used in the secondary beams. Seven wire steel strands of 15 mm diameter conforming to ASTM A416 were used. Figure 13 shows an overview of the floor slab before casting concrete. Details of the intersection between the main and secondary beams are shown in Fig. 14. The characteristic concrete strength was 35 MPa after 28 days and 30 MPa at time of prestressing. The prestressing sequence of the cables was designed to maintain minimum straining actions in the beams during tensioning. 50% of the cables in the main beams were tensioned first, followed by full force in the secondary beams. The remaining part of the prestressing forces in the beams was jacked. After ping the formwork of the first floor, Props were left to support the slab to help carrying the weight of the concrete slab in the second floor. Third case study The first LEED certified project in Egypt and Africa; the 21,000 m 2 LEED Gold Certified HSBC Egypt Global Service Centre is a four-story building with two levels of underground parking located in Egypt s Smart Village Cairo master-planned development. The building serves as a regional and global hub for HSBC s Middle East and Europe and has been designed and constructed to LEED standards (Leadership in Energy and Environmental Design) an international green building rating system by USGBC (United States Green Building Council). The building consists of two basements, ground and three typical floors with semi-circle shape in plan, as shown in Fig. 15. Fig. 17 Typical plan of the office building 5T10/m` 5T10/m` 5T10/m` 5T10/m` Min.2cm Mortar Fig. 18 Typical cross section of the slab

11 Innov. Infrastruct. Solut. (2017) 2:42 Page 11 of prestressing pattern of the concrete floors was chosen so that the distributed tendons were in the radial direction, while the banded tendons were in the tangential direction, as shown in the figure. Fourth case study Fig. 19 Plan of a typical panel in the slab The fourth case study is an office building, which consists of two basements, ground, three typical floors and a roof. The typical floor has an area of 9000 m 2 with spacing between columns up to m. The building was divided into three parts, as shown in Fig. 17. The slab is a ribbed slab with a depth of only 600 mm and Prestressed in both directions and supported on embedded post-tensioned beams with 600 mm depth, as shown in Figs. 18 and 19. The choice of this structural system allowed for a minimum depth to result in the largest possible clear height of the floor. Due to the small stiffness of the slab, a detailed vibrational analysis of the slab was carried out to provide comfort for the users of the building. The project was successfully completed in Fifth case study Fig. 20 Plan of the water tank showing sequence of construction The total length of the curved façade was 125 m, which was divided into three parts with pour s, as shown in Fig. 16. Each part was cast separately in order to minimize the concrete shrinkage effect on the floors and columns. The pour s separating the adjacent parts were cast after 30 days from casting the last concrete part. The The fourth case study is a water tank with overall dimensions of m divided by expansion joints into 15 parts, as shown in Fig. 20. The slab-on-ground has a variable thickness of 300/600 mm, while the elevated slab has a variable thickness of 280/400 mm, as shown in Fig. 21. Both slabs were post-tensioned in both directions using banded tendons in one direction and distributed tendons in the other direction. Computation of the losses in the prestressing force due to friction with the soil was a challenging parameter in the design. Overestimating the friction between the slab-on-ground and the soil will result in less compression on the concrete slab than the actual value. Sequence of casting was carefully selected, asshowninfig.20, in order to minimize the cold joints in the slab. Several concrete pockets were introduced to allow for prestressing when an adjacent part is already cast. Fig. 21 Typical cross section of the water tank

12 42 Page 12 of 12 Innov. Infrastruct. Solut. (2017) 2:42 Conclusions A computer code was made to optimize the prestressing cable profile and design of statically indeterminate posttensioned slabs. The Egyptian Code for Design and Construction of Reinforced Concrete Structures ECP addresses design of PT members. Several case studies are presented proving the feasibility of post-tensioned slabs in terms of cost and construction time. References Division of the South African Institution of Civil Engineering and the Institution of Structural Engineers 2. Aboueleied A (1958) An investigation of two-span continuous prestressed concrete beams, M.Sc Thesis, Cairo University, p Ministry of Housing, Utilities and Urban Communities (2001) The Egyptian Code for Design and Construction of Reinforced Concrete Structures ECP , Ministerial No. 208, 2nd edn 4. American Concrete Institute (2002) Building code requirements for structural concrete (ACI 318 m-02) and commentary (ACI 318rm-02), p British Standards Institution (1997) Structural use of concrete, part 1. Code of practice for design and construction, BS Collins MP, Mitchel D (1997) Prestressed concrete structures. Response Publications, London 7. Bondy K (2003) Moment redistribution: principles and practice using ACI PTI J: The South African Institution of Civil Engineering (2001) Design of prestressed concrete flat slabs. Report of Joint Structural

ST7008 PRESTRESSED CONCRETE

ST7008 PRESTRESSED CONCRETE ST7008 PRESTRESSED CONCRETE QUESTION BANK UNIT-I PRINCIPLES OF PRESTRESSING PART-A 1. Define modular ratio. 2. What is meant by creep coefficient? 3. Is the deflection control essential? Discuss. 4. Give

More information

POST-TENSIONING APPLICATION AND TECHNOLOGY. Moe Kyaw Aung

POST-TENSIONING APPLICATION AND TECHNOLOGY. Moe Kyaw Aung POST-TENSIONING APPLICATION AND TECHNOLOGY Moe Kyaw Aung Overview 1. Background 2. Basic Design Concept 3. Application and Benefits 4. Components of Post-tensioning System 5. Installation Process 6. Construction

More information

POST TENSIONED SLABS. Imagineering the possibilities

POST TENSIONED SLABS. Imagineering the possibilities POST TENSIONED SLABS Imagineering the possibilities imagineering... CCL post - tensioned slab solutions represent continuous development through involvement in building structures worldwide. CCL systems

More information

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures CFA Technical Note: 008-2010 A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures CFA Technical This CFA Technical Note is intended to serve as a guide to assist

More information

The Hashemite University Department of Civil Engineering. Dr. Hazim Dwairi. Dr. Hazim Dwairi 1

The Hashemite University Department of Civil Engineering. Dr. Hazim Dwairi. Dr. Hazim Dwairi 1 Department of Civil Engineering Lecture 2.1 Methods of Prestressing Advantages of Prestressing Section remains uncracked under service loads Reduction of steel corrosion (increase durability) Full section

More information

Hyperstatic (Secondary) Actions In Prestressing and Their Computation

Hyperstatic (Secondary) Actions In Prestressing and Their Computation 5.5 Hyperstatic (Secondary) Actions In Prestressing and Their Computation Bijan O Aalami 1 SYNOPSIS This Technical Note describes the definition, computation, and the significance of hyperstatic (secondary)

More information

Design of Post Tensioned Slab (Review)

Design of Post Tensioned Slab (Review) Design of Post Tensioned Slab (Review) Arun S. Bhutekar, Kishor S. Mirge, Bhavna Mhaske, Mangesh J. Sarkate, Prof,N. N. Shinde Department Civil Engineering, Email: bhutekararun143@gmail.com ABSTRACT- The

More information

Sabah Shawkat Cabinet of Structural Engineering 2017

Sabah Shawkat Cabinet of Structural Engineering 2017 3.1-1 Continuous beams Every building, whether it is large or small, must have a structural system capable of carrying all kinds of loads - vertical, horizontal, temperature, etc. In principle, the entire

More information

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES F. El M e s k i 1 ; M. Harajli 2 1 PhD student, Dept. of Civil and Environmental Engineering, American Univ. of Beirut;

More information

Strength Design of Reinforced Concrete Structures

Strength Design of Reinforced Concrete Structures Chapter 6 Strength Design of Reinforced Concrete Structures 6.1 Analysis and Design General Considerations 6.1.1 Convention and Notation Unless otherwise explicitly stated, the following units shall be

More information

CHAPTER 11: PRESTRESSED CONCRETE

CHAPTER 11: PRESTRESSED CONCRETE CHAPTER 11: PRESTRESSED CONCRETE 11.1 GENERAL (1) This chapter gives general guidelines required for the design of prestressed concrete structures or members with CFRM tendons or CFRM tendons in conjunction

More information

1. Cast-in-place concrete is specified in Section

1. Cast-in-place concrete is specified in Section SECTION 03 38 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for furnishing and installing post-tensioned slabs, jacks, jacking and anchors at Parking Structure, and record

More information

CSU GUIDELINES. April 27, 2018 FOR POST-TENSIONED CONCRETE STRUCTURES.

CSU GUIDELINES. April 27, 2018 FOR POST-TENSIONED CONCRETE STRUCTURES. CSU GUIDELINES FOR POST-TENSIONED CONCRETE STRUCTURES April 27, 2018 http://www.calstate.edu/cpdc/ae California State University Seismic Review Board Technical Guidelines January 9, 2018 The CSU Seismic

More information

Section A A: Slab & Beam Elevation

Section A A: Slab & Beam Elevation CE 331, Spring 2011 Flexure Strength of Reinforced Concrete s 1 / 5 A typical reinforced concrete floor system is shown in the sketches below. The floor is supported by the beams, which in turn are supported

More information

Structural Option April 7 th, 2010

Structural Option April 7 th, 2010 Gravity System (Depth Topic I) Post Tensioned Slab A new floor system was designed in an attempt to create a more consistent flooring system throughout the entire building. This new design consists of

More information

THEORETICAL AND EXPERIMENTAL STUDY OF UNBOUNDED POST-TENSIONED CONTINUOUS SLAB DECKS CONSISTING OF HIGH STRENGTH SCC

THEORETICAL AND EXPERIMENTAL STUDY OF UNBOUNDED POST-TENSIONED CONTINUOUS SLAB DECKS CONSISTING OF HIGH STRENGTH SCC CD02-017 THEORETICAL AND EXPERIMENTAL STUDY OF UNBOUNDED POST-TENSIONED CONTINUOUS SLAB DECKS CONSISTING OF HIGH STRENGTH SCC A.A. Maghsoudi 1, M. Torkamanzadeh 2 1 Associate. Prof., Civil Engineering.

More information

Two-way slabs. Flat plate with or without drop panels / capitals

Two-way slabs. Flat plate with or without drop panels / capitals Two-way slabs Two-way slab behavior is described by plate bending theory which is a complex extension of beam bending. Codes of practice allow use of simplified methods for analysis and design of two-way

More information

SECTION 1 INTRODUCTION TO POST-TENSIONED CONCRETE DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE

SECTION 1 INTRODUCTION TO POST-TENSIONED CONCRETE DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE SECTION 1 INTRODUCTION TO POST-TENSIONED CONCRETE DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE NOTE: MOMENT DIAGRAM CONVENTION In PT design, it is preferable to draw moment diagrams to the tensile

More information

Comparative Study on Post - Tensioned and Reinforced Concrete flat Slab Systems for a Multistory Building

Comparative Study on Post - Tensioned and Reinforced Concrete flat Slab Systems for a Multistory Building Comparative Study on Post - Tensioned and Reinforced Concrete flat Slab Systems for a Multistory Building Thayapraba M Civil Department, NIT Trichy, (India) ABSTRACT Designers have a huge number of choices

More information

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams 111 Nonlinear Models of Reinforced and Post-tensioned Concrete Beams ABSTRACT P. Fanning Lecturer, Department of Civil Engineering, University College Dublin Earlsfort Terrace, Dublin 2, Ireland. Email:

More information

In-plane testing of precast concrete wall panels with grouted sleeve

In-plane testing of precast concrete wall panels with grouted sleeve In-plane testing of precast concrete wall panels with grouted sleeve P. Seifi, R.S. Henry & J.M. Ingham Department of Civil Engineering, University of Auckland, Auckland. 2017 NZSEE Conference ABSTRACT:

More information

An Overview on Tendon Layout for Prestressed Concrete Beams

An Overview on Tendon Layout for Prestressed Concrete Beams P P P Assistant P Assistant P P PG P P HOD, IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 9, September 2015. An Overview on Tendon Layout for Prestressed

More information

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode Update: August 2016 Copyright ADAPT Corporation all rights reserved ADAPT-PT/RC 2016-Tutorial- 1 This ADAPT-PTRC 2016 Getting Started Tutorial is

More information

DIRECT DESIGN METHOD DDM

DIRECT DESIGN METHOD DDM DIRECT DESIGN METHOD DDM Load Transfer Path For Gravity Loads All gravity loads are basically Volume Loads generated due to mass contained in a volume Mechanism and path must be found to transfer these

More information

CVEN 483. Structural System Overview

CVEN 483. Structural System Overview CVEN 483 Structural System Overview Dr. J. Bracci Fall 2001 Semester Presentation Overview 1. Building system primary function 2. Types of load 3. Building materials 4. Structural members 5. Structural

More information

PROFESSIONAL DEVELOPMENT SERIES

PROFESSIONAL DEVELOPMENT SERIES Post-Tensioning for Two-Way Flat Plate Construction By Amy Reineke Trygestad, P.E. PROFESSIONAL DEVELOPMENT SERIES October 2005 Professional Development Series Every major metropolitan area is getting

More information

TWO-WAY POST-TENSIONED SLABS WITH BONDED TENDONS

TWO-WAY POST-TENSIONED SLABS WITH BONDED TENDONS PTI JOURNAL TECHNICAL PAPER TWO-WAY POST-TENSIONED SLABS WITH BONDED TENDONS By Kenneth B. Bondy Authorized reprint from: December 2012 issue of the PTI Journal Copyrighted 2012, Post-Tensioning Institute

More information

ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT

ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT Update: April 2010 Copyright ADAPT Corporation all rights reserved ADAPT-PT 2010-Tutorial- 1 Main Toolbar Menu Bar View Toolbar Structure

More information

Deflection Analysis with Shoring Load Transfer Coefficient for Post-Tensioned Slab

Deflection Analysis with Shoring Load Transfer Coefficient for Post-Tensioned Slab Deflection Analysis with Shoring Load Transfer Coefficient for Post-Tensioned Slab *Ah Sir Cho 1) and Thomas Kang 2) 1), 2) Department of Architecture & Architectural Engineering, Seoul National University,

More information

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS Qiang SHEN Graduate Research Assistant Yahya C. KURAMA Assistant Professor University of Notre Dame, Civil Engineering and Geological

More information

Two-way Slabs Using a Dual Banded Tendon Layout. Jonathan Hirsch Rashid Ahmed Asit Baxi

Two-way Slabs Using a Dual Banded Tendon Layout. Jonathan Hirsch Rashid Ahmed Asit Baxi Two-way Slabs Using a Dual Banded Tendon Layout Jonathan Hirsch Rashid Ahmed Asit Baxi Tendon Layouts - History Primary tendon layout in the 1950 s and 1960 s was the Basket Weave layout with 60/40 to

More information

THE DESIGN OF LONG CANTILEVER BEAM USING POST-TENSIONED TENDONS IN KUMJUNG STADIUM

THE DESIGN OF LONG CANTILEVER BEAM USING POST-TENSIONED TENDONS IN KUMJUNG STADIUM D.S. Choi (E-353) 1/6 THE DESIGN OF LONG CANTILEVER BEAM USING POST-TENSIONED TENDONS IN KUMJUNG STADIUM Dong-Sub Choi Jong-Soo Kim Dong-Hwan Kim C.S Structural Engineers Inc., #413-4, Tokok2 dong, Kangnam-Gu,

More information

Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle

Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle Overall Information Location: Singapore Date of Completion: 2010 Cost: $5.7 billion Architect: Moshe Safdie Executive Architect: Aedas, Pte

More information

Post-tensioned prestressed concrete bridge - assignment

Post-tensioned prestressed concrete bridge - assignment Post-tensioned prestressed concrete bridge - assignment Design a post-tensioned prestressed concrete bridge of a three-span arrangement. The construction is prestressed at the age of 7 days and put into

More information

Do It Right The First Time, Every Time And On Time. An Introduction to HERCULES LMK PT. Website:

Do It Right The First Time, Every Time And On Time. An Introduction to HERCULES LMK PT. Website: Do It Right The First Time, Every Time And On Time An Introduction to HERCULES LMK PT Content 1.Introduction 2.Post-Tensioning System 3.Typical Stressing Procedure 4.Typical Preliminary Design 5.PT Slab

More information

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET 1.0 Introduction USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET There is growing interest within the reinforced concrete industry

More information

Types of Foundations

Types of Foundations Shallow Foundations Types of Foundations Foundations can be classified to two major categories: Shallow. Deep. 1 Introduction If the soil stratum is suitable for supporting the structural loads from the

More information

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND AND Introduction to Structural Analysis TYPES OF STRUCTURES LOADS INTRODUCTION What is the role of structural analysis in structural engineering projects? Structural engineering is the science and art

More information

7.1 Transmission of Prestress (Part I)

7.1 Transmission of Prestress (Part I) 7.1 Transmission of Prestress (Part I) This section covers the following topics. Pre-tensioned Members 7.1.1 Pre-tensioned Members The stretched tendons transfer the prestress to the concrete leading to

More information

***************************************************************************************************************

*************************************************************************************************************** 03365 POST-TENSIONED CONCRETE *************************************************************************************************************** SPECIFIER: CSI MasterFormat 2004 number 03 38 00. ***************************************************************************************************************

More information

One-Way Wide Module Joist Concrete Floor Design

One-Way Wide Module Joist Concrete Floor Design One-Way Wide Module Joist Concrete Floor Design A 1 3 4 30'-0" 30'-0" 30'-0" 3' B 3' C 3' D 3' E 4" 4" (typ.) 3' F 0" 0" (typ.) Figure 1 One-Way Wide Module Joist Concrete Floor Framing System 1 Overview

More information

Seismic Detailing of RC Structures (IS: )

Seismic Detailing of RC Structures (IS: ) Seismic Detailing of RC Structures (IS:13920-1993) Sudhir K Jain Indian Institute of Technology Gandhinagar November 2012 1 Outline This lecture covers: Covers important clauses of IS13920 With particular

More information

Fundamentals of Post Tensioned Concrete Design for Buildings

Fundamentals of Post Tensioned Concrete Design for Buildings Fundamentals of Post Tensioned Concrete Design for Buildings Part Three by John P. Miller Overview of This Course This is Part Two of a two-part course that covers the fundamentals of post-tensioned concrete

More information

> 0. 1 f, they are treated as beam-columns.

> 0. 1 f, they are treated as beam-columns. 223 A- Flexural Members (Beams) of Special Moment Frames Requirements of ACI 21.5 are applicable for special moment frame members proportioned primarily to resist flexure with factored axial forces 0.

More information

A Research on Comparison of R.C.C and Post Tensioned Flat Slab with or Without Drop Using Software

A Research on Comparison of R.C.C and Post Tensioned Flat Slab with or Without Drop Using Software 2016 IJSRSET Volume 2 Issue 2 Print ISSN : 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology A Research on Comparison of R.C.C and Post Tensioned Flat Slab with or Without Drop

More information

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE SECTION 1. mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE 1.1 Overview of AS 3600:2009 AS 3600:2009 is the latest Australian

More information

1.7 Prestressing Steel

1.7 Prestressing Steel 1.7 Prestressing Steel This section covers the following topics. Forms of Prestressing Steel Types of Prestressing Steel Properties of Prestressing Steel Codal Provisions of Steel 1.7.1 Forms of Prestressing

More information

Modelling of RC moment resisting frames with precast-prestressed flooring system

Modelling of RC moment resisting frames with precast-prestressed flooring system Modelling of RC moment resisting frames with precast-prestressed flooring system B.H.H. Peng, R.P. Dhakal, R.C. Fenwick & A.J. Carr Department of Civil Engineering, University of Canterbury, Christchurch.

More information

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Executive Summary The proposed thesis will include an investigation of two different alternative structural

More information

Parametric Study of Continuous Concrete Beam Prestressed with External Tendon

Parametric Study of Continuous Concrete Beam Prestressed with External Tendon Parametric Study of Continuous Concrete Beam Prestressed with External Tendon Assistant Professor, College of Engineering, Diyala University, Iraq ABSTRACT This paper presents the results of a parametric

More information

2012 IBC/2011 MSJC MASONRY CODE COMPILATION

2012 IBC/2011 MSJC MASONRY CODE COMPILATION 2012 IBC/2011 MSJC MASONRY CODE COMPILATION 2012 IBC CHAPTER 21 MASONRY Merged IBC/MSJC 2011 MSJC CODE CHAPTER 1 BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES SECTION 2101 GENERAL

More information

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer: Chapter II. REVIEW OF PREVIOUS RESEARCH II.1. Introduction: The purpose of this chapter is to review first the basic concepts for earthquake engineering. It is not intended to review the basic concepts

More information

14.1 PCI Standard Design Practice

14.1 PCI Standard Design Practice SPECIFICATIONS AND STANDARD PRACTICES Chapter.1 PCI Standard Design Practice Precast and prestressed concrete structures have provided decades of satisfactory performance. This performance is the result

More information

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8 WISCONSIN PLACE RESIDENTIAL TECHNICAL ASSIGNMENT 2 OCTOBER 29, 2007 KURT KRASAVAGE THE PENNSYLVANIA STATE UNIVERSITY STRUCTURAL OPTION FACULTY ADVISOR: DR. ALI MEMARI 1 Table of Contents Table of Contents.2

More information

Flexure Design Sequence

Flexure Design Sequence Prestressed Concrete Beam Design Workshop Load and Resistance Factor Design Flexure Design Flexure Design Sequence Determine Effective flange width Determine maximum tensile beam stresses (without prestress)

More information

The cracking behaviour of reinforced concrete beams under static and dynamic loading

The cracking behaviour of reinforced concrete beams under static and dynamic loading The cracking behaviour of reinforced concrete beams under static and dynamic loading J.A. Huffadine, A.G. van Bysterveldt, G.C. Clifton & G.W. Ferguson Department of Civil Engineering, University of Auckland,

More information

Technical Assignment 1 10/8/03

Technical Assignment 1 10/8/03 Executive Summary Technical Assignment 1 10/8/03 The is 55 story high-rise condominium being built off the northern Miami coast. The structural design presented in this building is a direct result of its

More information

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition CHAPTER REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition Fifth Edition REINFORCED CONCRETE A. J. Clark School of Engineering Department of Civil and Environmental Engineering

More information

Franklin Square Hospital Center Patient Tower

Franklin Square Hospital Center Patient Tower Thomas Weaver Structural Option Franklin Square Hospital Center Patient Tower Baltimore, MD Thomas Weaver Structural Option AE 481W Senior Thesis Consultant: Professor M. Kevin Parfitt 12/14/2009 Page

More information

Fundamentals of Post-Tensioned Concrete Design for Buildings

Fundamentals of Post-Tensioned Concrete Design for Buildings Fundamentals of Post-Tensioned Concrete Design for Buildings Part One by John P. Miller www.suncam.com Copyright 2012 John P. Miller Page 1 of 49 Overview of This Course This is Part One of a three-part

More information

Comparative Study of R.C.C and Steel Concrete Composite Structures

Comparative Study of R.C.C and Steel Concrete Composite Structures RESEARCH ARTICLE OPEN ACCESS Comparative Study of R.C.C and Steel Concrete Composite Structures Shweta A. Wagh*, Dr. U. P. Waghe** *(Post Graduate Student in Structural Engineering, Y.C.C.E, Nagpur 441

More information

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET Introduction There is growing interest within the reinforced concrete industry

More information

DUCTILITY REQUIREMENTS FOR BUILDINGS

DUCTILITY REQUIREMENTS FOR BUILDINGS DUCTILITY REQUIREMENTS FOR BUILDINGS Prof. P. C. Vasani, Applied Mechanics Department, L. D. College of Engineering, Ahmedabad 380015. profvasani@rediffmail.com Bhumika B. Mehta M. E. CIVIL - (CASAD) Sem

More information

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems Mohamad J. Terro Associate Professor. Civil Engineering Department, Kuwait University. Sameer

More information

5.4 Analysis for Torsion

5.4 Analysis for Torsion 5.4 Analysis for Torsion This section covers the following topics. Stresses in an Uncracked Beam Crack Pattern Under Pure Torsion Components of Resistance for Pure Torsion Modes of Failure Effect of Prestressing

More information

Practical Prestress Detailing

Practical Prestress Detailing Practical Prestress Detailing Disclaimer: "This presentation is for guidance only & is not to be taken as specific advice applicable to a particular project." This presentation will only cover bonded post-tensioning,

More information

Continuous Beam Design with Moment Redistribution (ACI )

Continuous Beam Design with Moment Redistribution (ACI ) Continuous Beam Design with Moment Redistribution (ACI 318-14) Continuous Beam Design with Moment Redistribution (ACI 318-14) A structural reinforced concrete continuous beam at an intermediate floor level

More information

Shear studs in slab-column connections with rectangular column

Shear studs in slab-column connections with rectangular column Shear studs in slab-column connections with rectangular column C B Tan*, Nanyang Techological University, Singapore s C Lee, Nanyang Techological University, Singapore s Teng, Nanyang Techological University,

More information

Lintel Tables Design Notes and Limitations

Lintel Tables Design Notes and Limitations LINTEL TABLES Lintel Tables Design Notes and Limitations 1. These tables apply to one and two family residential structures only that conform to the requirements of the 2006, 2009 or 2012 International

More information

Chapter. Masonry Design

Chapter. Masonry Design Chapter Masonry Design The masonry design section contains modules for the analysis of reinforced masonry beams subjected to pure bending and unreinforced masonry walls subjected to axial compression and

More information

Council on Tall Buildings

Council on Tall Buildings Structure Design of Sino Steel (Tianjin) International Plaza Xueyi Fu, Group Chief Engineer, China Construction Design International 1 1 Brief of Project 2 Location: Tianjin Xiangluowan Business District

More information

DESIGN FOR PROGRESSIVE COLLAPSE 1

DESIGN FOR PROGRESSIVE COLLAPSE 1 Your Partner in Structural Concrete Design TN447_progressive_collapse_110713 DESIGN FOR PROGRESSIVE COLLAPSE 1 Bijan O Aalami 2 This Technical Note outlines the design of column-supported conventionally

More information

Code Requirements for Nuclear Safety-Related Concrete Structures (ACI ) and Commentary An ACI Standard

Code Requirements for Nuclear Safety-Related Concrete Structures (ACI ) and Commentary An ACI Standard ACI 349-06 Code Requirements for Nuclear Safety-Related Concrete Structures (ACI 349-06) and Commentary An ACI Standard Reported by ACI Committee 349 Ronald J. Janowiak Chair Hansraj G. Ashar Partha S.

More information

GIRDER DESIGN FOR BUILDINGS

GIRDER DESIGN FOR BUILDINGS POST-TENSIONED TRANSFER GIRDER DESIGN FOR BUILDINGS Overload, Restraint and Construction Staging g Issues Almıla Uzel and Neb Erakovic (C) COPYRIGHT POST-TENSIONING INSTITUTE, ALL RIGHTS RESERVED Page

More information

PUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA

PUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA 2011 PUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA A. Ramos 1, V. Lúcio 2, D. Faria 3, M. Inácio 4 Abstract At the Civil Engineering Department of Universidade Nova de Lisboa punching research has been

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

Bijan Khaleghi, Ph, D. P.E., S.E.

Bijan Khaleghi, Ph, D. P.E., S.E. 0 Submission date: July, 0 Word count: 0 Author Name: Bijan Khaleghi Affiliations: Washington State D.O.T. Address: Linderson Way SW, Tumwater WA 0 INTEGRAL BENT CAP FOR CONTINUOUS PRECAST PRESTRESSED

More information

Special Reinforced Concrete Structural Walls

Special Reinforced Concrete Structural Walls 135 Special Reinforced Concrete Structural Walls The requirements of this section apply to special reinforced concrete structural walls serving as part of the earthquake force-resisting system. Shear Strength:

More information

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3 ISSN: 239-5967 ISO 900:2008 Certified Volume 4, Issue 5, September 205 Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain, Khaled Fawzy 2, and Mahmoud Nasr 3 Abstract-

More information

DEVELOPMENT OF THE STRUCTURAL DESIGN AND CONSTRUCTION GUIDELINE FOR HIGH-RISE PC BUILDINGS - JAPANESE PC PROJECT

DEVELOPMENT OF THE STRUCTURAL DESIGN AND CONSTRUCTION GUIDELINE FOR HIGH-RISE PC BUILDINGS - JAPANESE PC PROJECT 16 DEVELOPMENT OF THE STRUCTURAL DESIGN AND CONSTRUCTION GUIDELINE FOR HIGH-RISE PC BUILDINGS - JAPANESE PC PROJECT Fumio WATANABE 1, Shin OKAMOTO And Hisahiro HIRAISHI 3 SUMMARY Prestressed concrete has

More information

MIDAS Training Series

MIDAS Training Series MIDAS midas Civil Title: All-In-One Super and Sub Structure Design NAME Edgar De Los Santos / MIDAS IT United States 2016 Substructure Session 1: 3D substructure analysis and design midas Civil Session

More information

Technical Notes POST-TENSIONING IN GROUND-SUPPORTED SLAB 1. Bijan O Aalami 2 First draft

Technical Notes POST-TENSIONING IN GROUND-SUPPORTED SLAB 1. Bijan O Aalami 2 First draft Post-Tensioning Expertise and Design August 11, 2014 TN207_sog_stresses_4 POST-TENSIONING IN GROUND-SUPPORTED SLAB 1 Bijan O Aalami 2 First draft CONTENTS C.1 OVERVIEW C.2 ENGINEERS BENDING STRESS ASSUMPTIONS

More information

Principal Bridge Engineer Middle East & India Atkins Abu Dhabi, UAE

Principal Bridge Engineer Middle East & India Atkins Abu Dhabi, UAE Design of continuity slabs and the 020 Gajanan Chaudhari Principal Bridge Engineer Middle East & India Atkins Abu Dhabi, UAE Anand Panpate Senior Bridge Engineer Middle East & India Atkins Abu Dhabi, UAE

More information

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment Omar M. Ben-Sasi Abstract A total of fourteen slab-edge beam-column connection specimens were tested gradually to

More information

Applications of FRP Projects in Egypt

Applications of FRP Projects in Egypt Applications of FRP Projects in Egypt Abdel-Hady Hosny Emeritus Professor Ain Shams University, Cairo, Egypt Abdel-Hady Hosny received his PhD degree from Leeds Univ., Chairman of the Egyptian Engineering

More information

Design for Shear for Prestressed Concrete Beam

Design for Shear for Prestressed Concrete Beam Design for Shear for Prestressed Concrete Beam Introduction The behaviour of prestressed beams at failure in shear is distinctly different from their behaviour in flexure. The beam will tend to fail abruptly

More information

TORSION SIMPLIFIED: A FAILURE PLANE MODEL FOR DESIGN OF SPANDREL BEAMS

TORSION SIMPLIFIED: A FAILURE PLANE MODEL FOR DESIGN OF SPANDREL BEAMS TORSION SIMPLIFIED: A FAILURE PLANE MODEL FOR DESIGN OF SPANDREL BEAMS Gary Klein, Gregory Lucier, Sami Rizkalla, Paul Zia and Harry Gleich Biography: Gary Klein, FACI, is Executive Vice President and

More information

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS Weichen XUE Professor Tongji University Siping Road 1239#, Shanghai 200092, China xuewc@tongji.edu.cn*

More information

APPENDIX B ABC STRUCTURES DESIGN GUIDE

APPENDIX B ABC STRUCTURES DESIGN GUIDE APPENDIX B ABC STRUCTURES DESIGN GUIDE The Cohos Evamy Partners TABLE OF CONTENTS Page No. DISCLAIMER... I 1. STRUCTURAL DESIGN GUIDELINES... 1 2. GENERAL REQUIREMENTS (FIGURE B.2, STEP 1)... 1 3. GENERAL

More information

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure Performance based Displacement Limits for Reinforced Concrete Columns under Flexure Ahmet Yakut, Taylan Solmaz Earthquake Engineering Research Center, Middle East Technical University, Ankara,Turkey SUMMARY:

More information

PRESTRESSED CONCRETE SEISMIC DESIGN

PRESTRESSED CONCRETE SEISMIC DESIGN PRESTRESSED CONCRETE SEISMIC DESIGN K. E. Williamson* 1. Editorial Foreword This paper is reproduced from the proceedings of a seminar on "Seismic Problems in Structural Engineering" arranged by the Departments

More information

Flat Slabs. d 2. A typical flat slab (without drop and column head)

Flat Slabs. d 2. A typical flat slab (without drop and column head) 1 CHAPTER Flat Slabs 1.1 INTRDUCTIN Common practice of design and construction is to support the slabs by beams and support the beams by columns. This may be called as beam-slab construction. The beams

More information

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS D.S. Lunn 1,2, V. Hariharan 1, G. Lucier 1, S.H. Rizkalla 1, and Z. Smith 3 1 North Carolina State University, Constructed Facilities Laboratory,

More information

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating FLORUŢ SORIN-CODRUŢ*, NAGY-GYÖRGY TAMÁS*, STOIAN VALERIU*, DIACONU DAN* * Department of Civil Engineering

More information

WATER RESEARCH COMMISSION. KSA 1: Water Resource Management. Thrust 2: Management of Natural and Human-induced Impacts on Water Resources

WATER RESEARCH COMMISSION. KSA 1: Water Resource Management. Thrust 2: Management of Natural and Human-induced Impacts on Water Resources WATER RESEARCH COMMISSION KSA 1: Water Resource Management Thrust 2: Management of Natural and Human-induced Impacts on Water Resources P3: Integrated flood and drought management REPORT ON DESIGN CODES

More information

PUNCHING SHEAR STRENGTH OF GFRP REINFORCED DECK SLABS IN SLAB- GIRDER BRIDGES

PUNCHING SHEAR STRENGTH OF GFRP REINFORCED DECK SLABS IN SLAB- GIRDER BRIDGES IV ACMBS MCAPC 4 th International Conference on Advanced Composite Materials in Bridges and Structures 4 ième Conférence Internationale sur les matériaux composites d avant-garde pour ponts et charpentes

More information

Pile to Slab Bridge Connections

Pile to Slab Bridge Connections Pile to Slab Bridge Connections Mohamed I. Ayoub 1, David H. Sanders 2 and Ahmed Ibrahim 3 Abstract Slab bridges are a common bridge type, where the pile extends directly from the ground to the superstructure.

More information

Tips For Designing Constructable Concrete Buildings

Tips For Designing Constructable Concrete Buildings Tips For Designing Constructable Concrete Buildings by Clifford Schwinger, P.E. The Harman Group, Structural Engineers King of Prussia, Pa. Structural Engineers Association of Ohio Annual Conference Presentation

More information

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University November 16 th, 2007 William J. Buchko AE 481w Senior Thesis The Pennsylvania State University Thesis Advisor: Kevin Parfitt Table of Contents Executive Summary... 3 Structural System Overview Foundation...

More information