AAR Open Top Loading Rules Manual
|
|
- Brooke Little
- 6 years ago
- Views:
Transcription
1 Fig. 850 (New 01/06) (oncluded) HASSIS, GOOSNK 20 FT TO 40 FT LONG, FOUR-HIGH ON ONTAINR SHIPPING UNIT Notes and Additional Requirements (concluded): 11. Secure the chassis to the SU using all three Item B tie-down straps as follows: (Note: All three straps are to be removed from their storage position and used for either the 20-ft or 40-ft chassis loading.) 11.1.For loading three 20-ft chassis, two Item B straps are to be positioned over the top of the No. 3 chassis as shown in Sketch 1. A third Item B strap is positioned over the No. 2 chassis. If only two chassis are loaded, two Item B straps must be applied over the No. 2 chassis, with the third applied over the No. 1 chassis In loading 40-ft chassis, all three Item B straps are positioned over the top of the upper-most chassis, regardless of the number of chassis loaded Position each strap over the top of the appropriate chassis in alignment with one of the winch sets enter the protective (black) sleeves of the web strap over the sharp angles of the chassis frame so as to protect the webbing from damage Using the winch bar (located in a stowage cavity at the inside of the front left-hand corner of the SU), winch the Item B straps taut from each side of the SU to obtain uniform tension. After the straps are tightened, return the winch bar to the stowage location. Note: If the stowed winch bar is not available, a steel bar 24 in. long and no greater is to be used to tighten the straps. This is to ensure the straps are adequately tightened without applying an excessive amount of force on the chassis After tightening, check that the protective sleeves remain properly positioned to avoid damage to the tie-down webbing. 12. When loading the SU on a 45-ft ground chassis, the SU shall be placed on the chassis so the rear-most ISO sockets of the SU engage the chassis twistlocks and the chassis front pins can engage the slots of the SU. Lock the twistlocks of the chassis and engage the front chassis pins. 13. The fork pockets are to be used only when the SU is empty. Lifting and placing the loaded SU on a OF railcar shall be performed using a container handler with the spreader retracted to the 20-ft ISO position. The SU is to be picked up by the F2 and F3 stanchion locations only. The top-lift operation is the same as that for a standard 20-ft container in OF service. 14. When transporting empty SUs, the eight stanchions of the SU are to be folded down and locked to create a flat-rack. (See Detail A.) Four SUs can be connected together using ISO interbox connectors (IBs). (See Sketch 3.)The four inter-connected SUs can be handled with standard container handling equipment retracted to the 20-ft ISO position. Reference the General Rules in Section No. 1 of the Open Top Loading Rules Manual for additional details. 03/ Section 7, Part 3
2 Fig. 902 (Rev. 07/11) (New 9/90) LUMBR, 6 FT LONG OR OVR, PAKAGD FLAT RAK ONTAINRS, WITH BULKHADS Item No. of Pcs. Description A 2 per pkg. Bearing pieces: lumber, 2 in. 4 in., in one piece, length to extend beyond sides of load, but not beyond container sides. B 2 per pkg. Separators: lumber, 2 in. 4 in., in one piece. Length equal to width of package. May be attached to package with Item package ties. Length of separators may be equal to width of load, if side-by-side packages are equal height. 2 per pkg. Package bands: 5/8 in..020 in. high tension bands. Locate one about one-fourth length from each end of package. D 2 per pile 10 ft long or less. 3 per pile over 10 ft long up to and including 16 ft. 4 per pile over 16 ft long. ncircling bands: 1 1/4 in..029 in. high tension, encircling entire pile. Locate not less than 9 in. in from ends of pile when possible. May be substituted with approved 1 5/8-in.-wide Type IA, Grade 6, polyester strapping per Section 1, General Rule 19. F 2 per pile 10 ft long Tie down bands: 1 1/4 in..029 in. high tension. Pass over top of load and secure to lading strap or less. anchors on each side of container. May be substituted with approved 1 5/8-in.-wide Type IA, Grade 6, 3 per pile over polyester strapping per Section 1, General Rule ft long up to and including 16 ft. 4 per pile over 16 ft long. 1 band on top package on either side of a void space greater than 4 ft. and on both ends of load when packages are above bulkheads. ompression package band: 1 1/4 in..029 in. high tension band. May be substituted with approved 1 1/4-in.-wide Type IA, Grade 4, polyester strapping per General Rule 19, Section 1. Locate near the center of the package as shown in Detail A. In accordance with Detail A, apply compression blocks, one on top of each package (or packages) and one on each side of the package (or outer packages) as shown. Blocks are to be lumber, minimum 2 in. 4 in., length equal to about one third the width of the surface to which they are to be applied. Position each block centrally across the package surface as shown. Secure each block with a minimum of two nails. The nail length must be sufficient to penetrate package material at least 1 in. and have about 3/4 in. remaining above the block. ncircle the package with the band, placing it over each block, then bend the nail heads over the band as shown. See Sketch 1, Detail A and B. See Sketch 2 for required location of compression package(s). Section 7, Part /2010
3 Fig. 902 (Rev. 07/11) (ontinued) (New 9/90) LUMBR, 6 FT LONG OR OVR, PAKAGD FLAT RAK ONTAINRS, WITH BULKHADS Item No. of Pcs. Description Notes and Additional Requirements: 1. Maximum width of package must not exceed 4 ft; height must not exceed width. 2. All packages within the load must be loaded perpendicular to bulkheads. 3. At point of origin, load must be centered on container. 4. All packages must be butted as close together as possible. 5. Use of stickers within the individual packages is optional. When used they must be uniform thickness throughout. Length of stickers must not exceed width of packages. 6. Packages must not exceed height of bulkhead. 7. All packages must be composed of pieces of uniform width, length, and thickness. 8. Laminated bearing pieces and separators are not permitted unless AAR approved and stamped. 9. Attached dunnage may be applied to either the top or bottom of packages. If applied to the top of packages, all dunnage in the top layer must have one 10-D nail applied in addition to the package band, to prevent displacement. 10. When using non-metallic strapping, edge protectors must be used. 11. Top packages on either side of a void space greater than 4 ft must be protected using Item F. A top layer package is defined as any package with no packages loaded directly above. A package that is not completely covered by a package above is also considered a top package and is required to have a compression package band applied. Packages at the end of the flat rack container higher than the bulkhead means any packages that are partially or fully above the bulkhead Reference the General Rules in Section No. 1 of the Open Top Loading Rules Manual for additional details. 03/ Section 7, Part 3
4 Fig. 902 (Rev. 07/11) (ontinued) (New 9/90) LUMBR, 6 FT LONG OR OVR, PAKAGD FLAT RAK ONTAINRS, WITH BULKHADS SKTH 1 DTAILS A AND B DTAIL A DTAIL B Section 7, Part /2010
5 Fig. 902 (Rev. 07/11) (oncluded) (New 9/90) LUMBR, 6 FT LONG OR OVR, PAKAGD FLAT RAK ONTAINRS, WITH BULKHADS SKTH 2 03/ Section 7, Part 3
6 Fig. 910 (Rev. 07/11) (New 9/94) LUMBR, 5 FT LONG OR OVR, PAKAGD FLAT RAK ONTAINRS, WITH BULKHADS AND POLYSTR WBBING TI-DOWN SYSTM D OR ALT. D Item No. of Pcs. Description A 2 per package 8 ft long or less, 3 over 8 ft to 16 ft, inclusive, 4 over 16 ft. Bearing pieces: lumber, 2 in. 4 in. in one piece. Length to extend beyond sides of load, but not beyond container sides. B D 2 per package 8 ft long or less, 3 over 8 ft to 16 ft, inclusive, 4 over 16 ft. 2 per package 14 ft long or less. Add 1 for each additional 5 ft or less. 2 per each package 8 ft long or less, 3 per package over 8 ft to 16 ft inclusive, 4 per package over 16 ft. 1 per each package 8 ft long or less, 2 per package over 8 ft. Separators: lumber, 2 in. 4 in., in one piece. Length equal to width of package. May be attached to package with Item package ties. Length of separators may be equal to width of load, if side-by-side packages are equal height. Package ties: 1,275 lb minimum breaking strength, high tension bands or wire, except on packages exceeding 26 in. high, high tension bands or wire with minimum breaking strength of 1,600 lb. Locate end tie approximately one-fourth from each end of package with others, when needed, equally spaced. This banding may be substituted with approved nonmetallic strapping as shown in General Rule Load retaining straps: polyester webbing with 4,300 lb working load limit. Locate over top of load and secure to opposite side of container. Winch taut. Load retaining straps: polyester webbing with 4,300 lb working load limit. Locate over packages in the bottom layer and secure to opposite side of container. Winch taut (used only in conjunction with Item D). A B Section 7, Part /2010
7 Fig. 910 (Rev. 07/11) (ontinued) (New 9/94) LUMBR, 5 FT LONG OR OVR, PAKAGD FLAT RAK ONTAINRS, WITH BULKHADS AND POLYSTR WBBING TI-DOWN SYSTM Item No. of Pcs. Description F 1 band on top package ompression package band: 1 1/4 in..029 in. high tension band. May be substituted with approved on either side of a void space greater than 4 ft. and on both ends of load when 1 1/4-in.-wide Type IA, Grade 4, polyester strapping per General Rule 19, Section 1. Locate near the center of the package as shown in Detail A. In accordance with Detail A, apply compression blocks, one on top of each package (or packages) and one on each side of the package (or outer packages) as shown. packages are above Blocks are to be lumber, minimum 2 in. 4 in., length equal to about one third the width of the surface bulkheads. to which they are to be applied. Position each block centrally across the package surface as shown. Secure each block with a minimum of two nails. The nail length must be sufficient to penetrate package material at least 1 in. and have about 3/4 in. remaining above the block. ncircle the package with the band, placing it over each block, then bend the nail heads over the band as shown. See Sketch 1, Detail A and B. See Sketch 2 for required location of compression package(s). Alternate Item D D 2 per each package 8 ft long or less, 3 per package over 8 ft to 16 ft inclusive, 4 over 16 ft. Load retaining straps: polyester webbing with 5,000 lb working load limit. Locate over top of load and secure to opposite side of container. Winch taut. Notes and Additional Requirements: 1. Maximum width of packages must not exceed 51 in. Height must not exceed width. 2. All packages must be loaded perpendicular to bulkheads. 3. At point of origin, load must be centrally located on container. 4. All packages must be butted as close together as possible. 5. All end packages in any layer must have a minimum of two Item D or Alternate Item D straps applied. 6. Use of stickers within the individual packages is optional. When used, they must be of uniform thickness throughout. Length must not exceed width of package. 7. Packages must not exceed height of bulkheads. 8. All packages must be composed of pieces of uniform width and thickness. 9. Laminated bearing pieces and separators are not permitted unless AAR approved and stamped. 10. Anchor clips on webbing must be secured with wire or other suitable means to prevent displacement. 11. All polyester webbing straps on container must be applied when practical. 12. Attached dunnage may be applied to either the top or bottom of packages. If applied to the top of packages, all dunnage in the top layer must have one 10-D nail applied in addition to the package band, to prevent displacement. 13. Top packages on either side of a void space greater than 4 ft must be protected using Item F. A top layer package is defined as any package with no packages loaded directly above. A package that is not completely covered by a package above is also considered a top package and is required to have a compression package band applied. Packages at the end of the flat rack container higher than the bulkhead means any packages that are partially or fully above the bulkhead Reference the General Rules in Section No. 1 of the Open Top Loading Rules Manual for additional details. 03/ Section 7, Part 3
8 Fig. 910 (Rev. 07/11) (ontinued) (New 9/94) LUMBR, 5 FT LONG OR OVR, PAKAGD FLAT RAK ONTAINRS, WITH BULKHADS AND POLYSTR WBBING TI-DOWN SYSTM SKTH 1 DTAILS A AND B DTAIL A DTAIL B Section 7, Part /2010
9 Fig. 910 (Rev. 07/11) (oncluded) (New 9/94) LUMBR, 5 FT LONG OR OVR, PAKAGD FLAT RAK ONTAINRS, WITH BULKHADS AND POLYSTR WBBING TI-DOWN SYSTM SKTH 2 03/ Section 7, Part 3
10 Fig. 912 (Rev. 07/11) (New 9/95) LUMBR, 8 FT LONG OR OVR, WITH OR WITHOUT UNQUAL LNGTHS, PAKAGD FLAT RAK ONTAINRS, WITH ND BULKHADS AND POLYSTR WBBING TI-DOWN SYSTM D Item No. of Pcs. Description A 3 per pile 16 ft long or less, 4 per pile over 16 ft. Bearing pieces: lumber, 2 in. 3 in. in one piece. Length to extend beyond side of load, but not beyond sides of the container. nd piece must be placed approximately 12 in. in from solid ends of packages. Remaining pieces to be equally spaced between. B 3 per pkg. 16 ft long or less, 4 per pkg. over 16 ft. 2 per pkg. 16 ft long or less, 3 per pkg. over 16 ft. Separators: lumber, 2 in. 3 in. in one piece. Length equal to width of package. If side-by-side packages are of equal height, separators may be in one piece with length equal to width of load. Locate in approximate vertical alignment with Item A. Package ties: 1,275 lb minimum breaking strength, high tension bands or wires. For packages exceeding 26 in. high, high tension bands or wires must have minimum breaking strength of 1,600 lb. Locate approximately 12 in. in from each solid end of package. Third package tie, when required, to be centered between end ties. This banding may be substituted with approved nonmetallic strapping as shown in General Rule D 2 per pile. ncircling bands: 1 1/4 in..029 in. high tension bands. ncircle entire pile approximately 9 in. in from solid ends of package. Minimum 2 per top pkg. 8 ft long, 3 per top pkgs. over 8 ft to 16 ft long, 4 per top pkg. 16 ft. Add 1 for each additional 4 ft or less. A B Load retaining straps: polyester webbing with 5,000 lb working load limit. Locate over top of load and secure to opposite side of container. Winch taut. All tie-downs must be used except over voids and soft ends of packages. Section 7, Part /2010
11 Fig. 912 (Rev. 07/11) (ontinued) (New 9/95) LUMBR, 8 FT LONG OR OVR, WITH OR WITHOUT UNQUAL LNGTHS, PAKAGD FLAT RAK ONTAINRS, WITH ND BULKHADS AND POLYSTR WBBING TI-DOWN SYSTM Item No. of Pcs. Description F 1 band on top package ompression package band: 1 1/4 in..029 in. high tension band. May be substituted with approved on either side of a void space greater than 4 ft. and on both ends of load when 1 1/4-in.-wide Type IA, Grade 4, polyester strapping per General Rule 19, Section 1. Locate near the center of the package as shown in Detail A. In accordance with Detail A, apply compression blocks, one on top of each package (or packages) and one on each side of the package (or outer packages) as shown. packages are above Blocks are to be lumber, minimum 2 in. 4 in., length equal to about one third the width of the surface bulkheads. to which they are to be applied. Position each block centrally across the package surface as shown. Secure each block with a minimum of two nails. The nail length must be sufficient to penetrate package material at least 1 in. and have about 3/4 in. remaining above the block. ncircle the package with the band, placing it over each block, then bend the nail heads over the band as shown. See Sketch 1, Detail A and B. See Sketch 2 for required location of compression package(s). Alternate Minimum 5 per top pkg. Load retaining straps: polyester webbing with 4,300 lb working load limit. Locate over top of load and secure to opposite side of container. Winch taut. All tie-downs must be used except over voids and soft ends of packages. Notes and Additional Requirements: 1. Minimum width of packages must not exceed 51 in. Height must not exceed width. 2. All packages must be loaded lengthwise on container. 3. At point of origin, load must be centrally located on container. 4. All packages must be butted as close together as possible. 5. Finished packages must have sides square and must be composed of pieces of uniform width and thickness. 6. Use of stickers within the individual packages is optional. When used they must be of uniform thickness throughout. 7. Packages must not exceed height of bulkheads. 8. Laminated bearing pieces and separators are not permitted unless AAR approved and stamped. 9. Anchor clips on webbing must be secured with wire or other suitable means to prevent displacement. 10. When lumber of unequal lengths is included in the same package, only the following variances are permitted: Solid 8-ft packages may include 10-, 12-, 14-, and 16-ft lengths. Solid 10-ft packages may include 12-, 14-, and 16-ft lengths. Solid 12-ft packages may include 14-, 16-, and 18-ft lengths. Solid 14-ft packages may include 16-, 18-, and 20-ft lengths. 11. When variations in lengths are greater than 4 ft, solid portion of package must be centrally located within package. 12. In 8-ft and 10-ft packages with mixed length lumber, no more than two layers of 8-ft or 10-ft lumber are permitted without longer length layers being applied. 13. Top packages on either side of a void space greater than 4 ft must be protected using Item F. A top layer package is defined as any package with no packages loaded directly above. A package that is not completely covered by a package above is also considered a top package and is required to have a compression package band applied. Packages at the end of the flat rack container higher than the bulkhead means any packages that are partially or fully above the bulkhead Reference the General Rules in Section No. 1 of the Open Top Loading Rules Manual for additional details. 03/ Section 7, Part 3
12 Fig. 912 (Rev. 07/11) (ontinued) (New 9/95) LUMBR, 8 FT LONG OR OVR, WITH OR WITHOUT UNQUAL LNGTHS, PAKAGD FLAT RAK ONTAINRS, WITH ND BULKHADS AND POLYSTR WBBING TI-DOWN SYSTM SKTH 1 DTAILS A AND B DTAIL A DTAIL B Section 7, Part /2010
13 Fig. 912 (Rev. 07/11) (oncluded) (New 9/95) LUMBR, 8 FT LONG OR OVR, WITH OR WITHOUT UNQUAL LNGTHS, PAKAGD FLAT RAK ONTAINRS, WITH ND BULKHADS AND POLYSTR WBBING TI-DOWN SYSTM SKTH 2 03/ Section 7, Part 3
14 Fig. 531 (Rev. 9/93) (New 6/70) PLYWOOD OR OMPOSITION BOARDS, PAKAGD FLATBD TRAILRS F D G A B 1" 6" 12" nds of pile only (Nail to triangular chock block with three 10-D nails) Item No. of Pcs. Description A 2 per package. Hardwood: 4 in. 6 in. length equal to width of load. B 2 ea. layer. Separators: hardwood, 2 in. 4 in. length equal to width of load. As required. Hardwood: triangular chock block. Secure with five 20-D nails. (Note 1) D 3 per package. High tension bands: 3/4 in..022 in., around each package. If dunnage is attached to packages with Item D bands, see OTLRM Section 1, General Rule per package. Spreader board: hardwood, 2 in. 4 in. length equal to width of load. F 4 per package. Top two-thirds and bottom two-thirds interlacing ties, 2 in..044 in. high tension band. G 2 per package. Binder chain: 3/8 in. HT or equivalent. Secure to opposite stake pockets. Notes and Additional Requirements: 1. Use at least one chock block, Item, at each end of load and on each side of individual piles. Locate on decking and against load near center of pile. 2. Laminated bearing pieces, separators and vertical stabilizers are not permitted unless AAR approved and stamped. Reference the General Rules in Section No. 1 of the Open Top Loading Rules Manual for additional details. Section 7, Part /2010
Click on image to enlarge.
Assembly Open the bundle and unfold each unit. Lift the sides, the ends and the diaphragms of each unit into vertical position. Attach the sides of four corners together with locking wire fastener or lacing
More informationACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings
ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory
More informationGeneral Information Series No in. to 50 in. Diameter Roll Paper on End Using Rubber Mats (New Intermodal Loading Guide Method E-21)
47 in. to 50 in. Diameter Roll Paper on End Using Rubber Mats Approved by DAMAGE PREVENTION & FREIGHT CLAIM COMMITTEE Association of American Railroads Issued May 2013 Published by Association of American
More informationMinimum Loading Standards for Intermediate Bulk Containers (Including Drums) in Closed Cars
Closed Car Loading Guide Part 7 Minimum Loading Standards for Intermediate Bulk Containers (Including Drums) in Closed Cars Approved June 25, 2014, by the Damage Prevention and Freight Claim Committee
More informationWalco Equipment has grown into a successful Canadian manufacturing & distribution Company.
WALCO CARGO CONTROL COMPONENTS WINCHES H.D. Small Frame ------Page 1 Portable-----------------Page 1 Loose Frame -----------Page 1 Weld-on ----------------Page 1 Low Profile -------------Page 2 Three Bar
More informationCan Process Scrap Specification
Rev 3 February 2018 Can Process Scrap Specification Document Manager: Kerry Ward Approved by: Michael Anderson Note: This is considered an uncontrolled document unless it is being viewed on-line from the
More informationHouston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College
SECTION 323113 - CHAIN LINK FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationStandard Duty Cantilever Rack Installation and Assembly Guide
Standard Duty Cantilever Rack Installation and Assembly Guide Steel King Industries, Inc. 2700 Chamber St Stevens Pont, WI 54481 (800) 826 0203 www.steelking.com info@steelking.com ASSEMBLY INSTRUCTIONS:
More informationSafety on Heights: Our Policy
11/17/14 Safety on Heights: Our Policy Only volunteers over the age of 18 are allowed to work on heights of more than six feet off the ground. This includes all work on scaffolds. Only volunteers who are
More informationOptiLedge Implementation Handbook
OptiLedge Implementation Handbook Page 1 The Index Introduction to the OptiLedge 3 OptiLedge Product Sheets 4 OptiLedge Specifications 5 OptiLedge Load Capacities 5 Solution Development and the Implementation
More informationNPCA Precast Learning Lab. Dunnage, Loading & Shipping. Precast Show 2017 NPCA 1
NPCA Precast Learning Lab What is it? A new library of short, educational videos What can I learn? Topics cover production best practices and sales and marketing How many videos are available? Four videos
More informationProfessional Grade Racking
UNIRAK STORAGE SYSTEMS Professional Grade Racking Stock Solutions Quick Ship Rack Intralogistics Optimized Rack North America has standardized the Tear Drop/ Riveted Beam End Plate design for good reason
More information4.6 Procedures for Connections
4.6 Procedures for Connections This section provides Tier 2 evaluation procedures that apply to structural connections: anchorage for normal forces, shear transfer, vertical components, interconnection
More informationPATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge
Assembly Manual 8x9 PATENTS ARE PENDING Approximate Size 7640303 Storage Area Building Dimensions Exterior Dimensions Roof Edge to Roof Edge Interior Dimensions Wall to Wall Sq. Ft. Cu. Ft. Width Depth
More informationGARAGES/ONE-STORY City of Grand Rapids Building Safety Division
GARAGES/ONE-STORY City of Grand Rapids Building Safety Division 218-326-7601 www.cityofgrandrapidsmn.com This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building
More informationPS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.
C.9. DOOR AND WINDOW OPENINGS Openings for doors and windows are formed with bucks, or frames, which are constructed to the rough opening dimensions required for the doors and windows to be installed.
More informationIndustry guidance for the safe operation of tilt-tray vehicles
Industry guidance for the safe operation of tilt-tray vehicles This document provides practical advice on meeting the Duty of Care requirements of the Occupational Safety and Health Act 1984 (the Act)
More informationFlotation Docking Systems, Inc.
GENERAL SPECIFICATIONS The following data outlines the design calculations and specifications around which Flotation Docking Systems, Inc. products are constructed. The use of such information for contract
More information(01) Thermo Bond Buildings Military Service Shelter: DOG KENNEL OPERATING AND SETUP MANUAL MSS-RP-1-20P
Thermo Bond Buildings Military Service Shelter: DOG KENNEL OPERATING AND SETUP MANUAL MSS-RP-1-20P Tool-free assembly Portable Durable Climate-controlled Warnings & Safety Quick overview Assembly Maintenance
More informationGeneral Information Series No. 768
Gearboxes Mounted on Sleds in 20 ft. Long ISO Containers Approved by DAMAGE PREVENTION & FREIGHT CLAIM COMMITTEE Association of American Railroads Issued September 2017 Published by Association of American
More informationSECTION 1043 FENCE MATERIAL
SECTION 1043 FENCE MATERIAL 1043.1 Scope. This specification covers the material required in the construction of chainlink fence and woven wire fence. 1043.2 Basis of Acceptance. The basis of acceptance
More informationTechnical Services Information Bureau
Technical Services Information Bureau INSTALLING ACOUSTICAL LAY-IN TYPE CEILINGS IN SEISMIC REGIONS AUGUST 2009 UPDATED MAY 2017 TECHNICAL BULLETIN This document covers the installation practices recognized
More informationThe entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35
Packaged-Products for Less-Than-Truckload (LTL) Shipment ISTA 3 Series General Simulation Performance Test PROCEDURE VERSION DATE Last TECHNICAL Change: MARCH 2017 Last EDITORIAL Change: MARCH 2017 For
More informationPERI PD 8 The cost-effective shoring for slab tables and high loads
PERI PD 8 The cost-effective shoring for slab tables and high loads Edition 06/2010 PERI GmbH Formwork Scaffolding Engineering P.O. Box 1264 89259 Weissenhorn Germany Tel +49 (0)7309.950-0 Fax +49 (0)7309.951-0
More informationAnchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi
STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel
More informationGeneral Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety
Instructions for Part # SC500-AF General Guidelines It is the user s responsibility to read and follow all instructions. Keep these instructions with the product at all times and review before each use.
More informationSELECTIVE PALLET RACK
SELECTIVE PALLET RACK Selective Pallet Rack 2 www.mecaluxusa.com Selective Pallet Rack Selective Pallet Rack is one of the best solutions for warehouses where it is necessary to keep a wide variety of
More informationInstalling DELTABEAM. Installation of DELTABEAM. Deliveries. Storage on-site
Installing DELTABEAM Installation of DELTABEAM These DELTABEAM installation instructions are intended to complement the project s erection plan. Peikko s technical support can help with the erection plan
More informationBasic Suspension Systems
CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system
More informationThe better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................
More informationSEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets
SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic
More informationIntroduction to Shipping
Introduction to Shipping Shipping is one of the most important areas where you, as a supplier, can help the mill. The safety of the load is our number-one focus. This section will cover the following aspects
More informationSECTION CHAIN LINK FENCES AND GATES
SECTION 32 31 13 CHAIN LINK FENCES AND GATES SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this section in specifying permanent chain
More informationMERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing
MERCHANTS METALS SECTION 32 31 13 COLORBOND CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements,
More informationTable of Contents. Page Title
Page Title Table of Contents 1 Floor plan/ Room utilization 2 Elevation (EAST) 3 Elevation (SOUTH) 4 Elevation (WEST) 5 Elevation (NORTH) 6 Foundation plan details 7 Foundation cross sections A Main grade
More informationINTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR THE TESTING AND ANALYSIS OF STEEL SHEET SHEATHING FOR WOOD AND COLD FORMED STEEL LIGHT
More informationColorado Chapter of the International Conference of Building Officials. Building Guide. The Colorado Chapter of the International
Building Guide Colorado Chapter of the International Conference of Building Officials Colorado Building Chapter of the International Guide Code Council Single Family Residential One Story Detached Garage
More informationCIRCULAR NO. 42-K (Supersedes Circular No. 42-J)
CIRCULAR NO. 2-K (Supersedes Circular No. 2-J) GENERAL RULES COVERING LOADING OF CARLOAD SHIPMENTS OF COMMODITIES IN CLOSED CARS Issued November 1, 2010 The "General Rules" quoted in AAR Circular No. 2-J,
More informationSuspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F
NWCB Technical Document SUSPENDED CEILINGS 401 Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F 10/09 This document has been revised based on current Building Code standards.
More informationSteel Door Frame Installation in Masonry Construction
Steel Door Frame Installation in Masonry Construction Steel Door Frame Installation in Masonry Construction This manual provides step-by-step instructions for the installation of a steel door frame in
More information1 Exam Prep Placing Reinforcing Bars Tabs and Highlights
1 Exam Prep Placing Reinforcing Bars Tabs and s These 1 Exam Prep Tabs are based on the CRSI Placing Reinforcing Bars Recommended Practices, 9 th Edition. Each 1 Exam Prep tabs sheet has five rows of tabs.
More informationSECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.
SECTION 02830 CHAIN LINK FENCES AND GATES (GALVANIZED) 1.0 GENERAL 1.1 Section Includes A. Fence framework, fabric, gates, and accessories. B. Excavation for post bases; concrete footing for posts. C.
More informationThe System Slotted Deflection Track (pat# 5,913,788)
The System Slotted Deflection Track (pat# 5,913,788) UBC 1997/CBC 1997 Section 702. Definitions A FIRE-RESISTIVE JOINT SYSTEM is an assemblage of specific materials or products that are designed, tested,
More informationMechanical Loading Dock Levelers
Mechanical Loading Dock Levelers With over 30 years of experience manufacturing quality loading dock equipment, Pentalift is your single-source supplier for loading dock levelers, dock lifts, dock seals
More informationModular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper
Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)
More informationGHSP Supplier Packaging Requirements and Guidelines
Revision History Revision Date Section Description Revised By 10/1/15 ALL Initial Release M. Weisenreder 04/04/2017 2.1 Added Inside carton dimensions for parts that are re-packed at GHSP, Box Style columns
More informationstorage solutions Averys group PAL RACK The high quality pallet storage system for goods of all sizes and weights.
storage solutions Averys group PAL RACK The high quality pallet storage system for goods of all sizes and weights. CONVENTIONAL PALLET RACKING The Stow Pal Rack system consists of a full range of basic
More informationCargotec improves the efficiency of cargo flows on land and at sea
Cargotec improves the efficiency of cargo flows on land and at sea Cargotec s daughter brands Hiab, Kalmar and MacGregor are recognised leaders in cargo and load handling Cargotec s sales totalled EUR
More informationBY DAYTON SUPERIOR. FormRight FORMING SYSTEM
BY DAYTON SUPERIOR FormRight FORMING SYSTEM System Design The FormRight concrete forming system is a modular design suitable in handset or gangform applications. Modular versatility Panels come in 23 different
More informationPOST FRAME BUILDING STANDARDS
CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 POST FRAME BUILDING STANDARDS 201.3
More informationCITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures
CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE - 268-5161 Residential Accessory Structures This information has been compiled for the benefit of any person
More informationTF-14. TF-14 Installation Guide
TF-14 Trench Drain Forming System Installation Manual TF-14 Installation Guide P.O. Box 837 # 259 Murdock Road # Troutman, NC 28166 Tel (704) 528-9806 # Fax (704) 528-5478 Toll free in the U.S., Canada,
More informationResidential Building Inspections
Residential Building Inspections Foundations, Grade Beams, Pile Caps, Foundation Pads 1. All trenches or excavations and formwork shall be in accordance with the size(s) and configuration(s) as per approved
More informationBNSF Intermodal Loading Guide
BNSF Intermodal Loading Guide Revised 2010 2011 Load And Ride Solutions TABLE OF CONTENTS SECTION I SECTION II SECTION III SECTION IV SECTION V SECTION VI SECTION VII General Information Trailer/Container
More information216 Upton Drive St. Joseph, MI Phone: [269] Fax: [269]
216 Upton Drive St. Joseph, MI 49085 CANTILEVER RACK SYSTEM Strong and durable structural steel construction No front posts unrestricted access to your product Arms adjustable on 4 centers to accommodate
More informationCHAPTER 6 TYPES OF CONSTRUCTION
CHAPTER 6 TYPES OF CONSTRUCTION SECTION 61 GENERAL 61.1 Scope. The provisions of this chapter shall control the classification of buildings as to type of construction. SECTION 62 CONSTRUCTION CLASSIFICATION
More informationMECHANICAL BRIDGING AND BRIDGING ANCHORAGE OF LOAD BEARING COLD-FORMED STEEL STUDS. Paul E. Lackey, EIT Nabil A. Rahman, Ph.D.
INTRODUCTION MECHANICAL BRIDGING AND BRIDGING ANCHORAGE OF LOAD BEARING COLD-FORMED STEEL STUDS Paul E. Lackey, EIT Nabil A. Rahman, Ph.D., PE Gary Bennett The purpose of this technical note is to provide
More informationGold Bond BRAND Gypsum Sheathing
BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant
More informationGHSP Supplier Packaging Requirements and Guidelines
Revision History Revision Date Section Description Revised By 10/1/15 ALL Initial Release M. Weisenreder 04/04/2017 2.1 Added Inside carton dimensions for parts that are re-packed at GHSP, Box Style columns
More informationCONSTRUCTION SURVEY. Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following:
CONSTRUCTION SURVEY PART 1 - GENERAL 1.01 SECTION INCLUDES Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following: A. Construction Survey: 1. Project
More informationInstallation Instructions
EconoDrain Trench Forming System Installation Instructions MultiDrain We Drain Your Site, Not Your Budget MultiDrain Systems, Inc. P.O. Box 88, Barium Springs, NC 28010 (704) 508-1010 or Toll Free 800-433-1119
More informationSingle Post Anchor Part Number Spectrum Lane ~ Missoula MT ~
Single Post Anchor Part Number 21700 7100 Spectrum Lane ~ Missoula MT 59808 800.791.8056 ~ www.spectrumproducts.com 21700 Man Rev B You have purchased a Spectrum Aquatics Single Post Anchor. Providing
More informationTechnical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION
Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION This Technical Notes contains the guide specifications in CSI format for Part III
More informationPLYWOOD FLOATING FLOOR
PLYWOOD FLOATING FLOOR Read First These suggestions represent generally accepted procedures for successful installation of Enka Building Products. These instructions may be followed, modified, or rejected
More informationSTANDARD OPERATING PROCEDURES MANUAL Material Planning & Logistics Futuris Automotive Interiors
STANDARD OPERATING PROCEDURES MANUAL Material Planning & Logistics Futuris Automotive Interiors [ Packaging Specifications for International Suppliers ] Version 1.0 [1] Copyright Futuris Automotive Interiors
More informationFIGURE R502.2 FLOOR CONSTRUCTION
CHAPTER 5 FLOORS 11 I SECTION R501 GENERAL R501.1 Application. The provisions of this chapter shall control the design and construction of the floors for all buildings including the floors of attic spaces
More informationROOFING APPLICATION STANDARD (TAS) No. 102(A)-95
ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, CLIPPED, RIGID, ROOF SYSTEMS (For Methods of Mechanical Attachment Excluding Clips,
More informationTYPICAL BEARING WALL FRAMING
BASIC WOOD FRAMING City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code,
More informationTEST REPORT. Rendered to: SENTINEL FENCE AND RAIL. For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post
TEST REPORT Rendered to: SENTINEL FENCE AND RAIL For: 120 in by 42 in Fully-Welded Aluminum Guardrail Assembly with Intermediate Support Post Report No: Report Date: 10/23/12 130 Derry Court York, PA 17406-8405
More informationSafe Transport of Steel Coils in Standard Dry Van and Open Top Containers
Safe Transport of Steel Coils in Standard Dry Van and Open Top Containers Sea conditions The weather is not always like this!!! Ordinary Sea Passage Specially in winter periods, sea passages are often
More informationR Code and Commentary for 2012 NC Residential Code final 03/06/13
R602.10 Code and Commentary for 2012 NC Residential Code final 03/06/13 Commentary italicized and printed in red 1. Section R602.10 -- provides charging language for two simplified bracing approaches (isolated
More informationGypLyner (walls) Metal framed wall lining system. GypLyner.
GypLyner GypLyner (walls) Metal framed wall lining system GypLyner is a cost-effective, virtually independent metal frame drylining system for lining walls. General purpose and suitable for all internal
More informationZurn Z874. Trench Drain System. Installation Instructions
Zurn Z874 Trench Drain System Installation Instructions Z874 Accessories Trench Drain System Below are the components of the Z874-X trench drain typical to an installation. Check your order to verify you
More informationIndustrial Shelving. Q Line, Z-Line/Steel Shelves, Bulk Storage and Heavy-Duty Reinforced Shelving SYSTEMS FOR SUCCESS
Industrial Shelving Q Line, Z-Line/Steel Shelves, Bulk Storage and Heavy-Duty Reinforced Shelving Q Line & Z-Line/Steel Shelving Heavy Duty Reinforced Shelving & Bulk Storage Shelving 2 Industrial Shelving
More informationSECTION CHAIN-LINK FENCES AND GATES 02821/1
SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where
More information6032 SH 3P Residential Shower Installation Instructions Gelcoat & Solid Surface Bathware
Tools/materials you might need for proper installation 6D galvanized screws 100% silicone caulking caulking gun acrylic latex caulk shims tape measure 1/8 drill bit Phillips screw driver cardboard china
More informationSECTION NON-STRUCTURAL METAL FRAMING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 09 22 16 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable
More informationWood Truss Restraint and Bracing Guide
BUILDERS Wood Truss Restraint and Bracing Guide Using Simpson Strong Tie Products To Meet the Recommendations of the Building Component Safety Information (BCSI) Guide (800) 999-099 www.strongtie.com Wood
More informationSECTION HANGERS AND SUPPORTS FOR PLUMBING
SECTION 22 05 29 HANGERS AND SUPPORTS FOR PLUMBING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationUpright Frame Selection Guide K-1000 is today s best teardrop pallet rack value. NOTES: K-1000 Selective Upright Capacity (pounds)
Pallet rack K-1000 K-1000 the strength and torsion resistance of closed column construction with the compatibility of teardrop design. Speedrack K-1000 VERSATILITY K-1000 offers a wide range of accessories
More informationGABIONS AND REVET MATTRESSES
GABIONS AND REVET MATTRESSES PART 1 - GENERAL 1.01 SECTION INCLUDES A. Gabions B. Revet Mattresses (Gabion Mattresses) 1.02 DESCRIPTION OF WORK A. Assembly and installation of gabions. B. Assembly and
More informationM7 Shelving for picking. for medium and heavy loads
M7 Shelving for picking for medium and heavy loads Storage system for manual picking of products following the man-togoods principle. Its main benefits are: - Possibility of storing medium to heavy loads.
More informationLight Duty Ramps. Loadingdocksupply.com PHONE:
Light Duty Ramps Light Duty Aluminum Dockplates Designed for use by pallet trucks, carts, and foot traffic the A & B model Aluminum Dockplate is lightweight and portable. Accomodates differentials up to
More informationHOT ROLLED STEEL FLAT PRODUCTS FOR STRUCTURAL FORMING AND FLANGING PURPOSES SPECIFICATION (Third Revision of IS 5986)
For Comments Only Draft Indian Standard Doc: MTD 4(4939) HOT ROLLED STEEL FLAT PRODUCTS FOR STRUCTURAL FORMING AND FLANGING PURPOSES SPECIFICATION (Third Revision of IS 5986) ICS 77.140.50 Not to be reproduced
More informationZurn Z886. 6" Perma-Trench. Installation Instructions
Zurn Z886 6" Perma-Trench Installation Instructions Z886 Accessories 6" [152mm] Wide Trench Drain System Below are the components of the Z886 trench drain typical to an installation. Check your order to
More informationUniversal Panels & Accessories
Universal Panels & Accessories Erection Procedures INTRODUCTION Use common sense when working with Scaffold Your Safety is our #1 Concern Universal Scaffolds are designed with your safety in mind every
More informationSection 6 - Loading/Unloading Rules, Regulations & Charges
Section 6 - Loading/Unloading Rules, Regulations & Charges DEFINITION - LOADING AND UNLOADING 600 Loading and unloading means the services of loading or unloading cargo between any place or point of rest
More informationMethod of Measurement for Road Works Series MM Structural Concrete
Method of Measurement for Road Works Series MM 1700 - CC-RMP-01700 December 2013 CC Construction & Commissioning Standards TRANSPORT INFRASTRUCTURE IRELAND (TII) PUBLICATIONS About TII Transport Infrastructure
More informationLow-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.
RM140A-R3 RM140A-M-R3 RM145A-R3 RM145A-M-R3 Small Office/Home Office (SOHO) Cabinets Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. Fit under most desktops in the
More informationSECTION METAL FLOOR PLATE STAIRS
SECTION 05513 - METAL FLOOR PLATE STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationYOUR LITE-DECK SECTIONS
General Information Warning - Serious injury or death may result from safety hazards caused by improper use or installation. When in doubt about proper use or installation of Lite-Deck, immediately contact
More informationCITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.
City of Fruitland Building Inspections 208 South Division Street Fruitland, Maryland 21826 410.548.2804 CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE GENERAL NOTES This design guide
More informationMeasuring Walls in Accordance with ARM4 - An Introductory Demonstration
Dublin Institute of Technology ARROW@DIT Other Resources School of Surveying and Construction Management 2017-11-20 Measuring Walls in Accordance with ARM4 - An Introductory Demonstration Tony Cunningham
More informationSPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...
SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL TABLE OF CONTENTS 5.1 General...5-1 5.2 Certification...5-1 5.3 Fabrication...5-1 5.4 Handling and Storage...5-1 5.5 Field Repair of Epoxy
More informationTECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9
MARKINGWALLING OF SAFETY GLASS SPANDREL CURTAIN PANELS FORMED TO COLDFROM ROOFS STACKED WINDOW 7.2 /25 January ARRANGEMENTS (First Issue) XXXX EXXON QUESTION Which factors should be taken into account
More informationLOADING ON MEANS OF TRANSPORT
PD 070721 ED D del 07/09/2016 Page 1/29 1. ITER DI APPROVAZIONE REDAZIONE C. Frescura Methods and time costing and testing VERIFICA G. Martinelli Italy Warehouse S. Sette Brazil A. Piccinno China F. Stasolla
More informationConstruction Procedures
Construction Procedures 2014 Rev. 1.6 1 Introduction This manual presents the methods and procedures necessary for the proper erection of a LOCK+LOAD retaining wall. problems later during the service life
More informationAutomotive and Mechanical Parts Packaging Guidelines and Designs
Automotive and Mechanical Parts Packaging Guidelines and Designs Responsible packaging can save you money and improve the safety and handling of your shipments. Follow these tips and design recommendations.
More informationGLASS WALL SPECIFICATIONS
GLASS WALL SPECIFICATIONS Series GA1 Ultra Acoustical, STC 45/46, Omni, Glass Wall PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional s Manually Operated Maximum Opening Height: 12'
More information1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:
SECTION 04220 CONCRETE UNIT MASONRY PART 1 - GENERAL 1.01 SCOPE: A. The CONTRACTOR shall furnish all labor, materials and equipment necessary for the masonry construction as shown on the drawings or as
More information