Equipment designated as OFOI is to be Owner Furnished Owner Installed and is shown for reference and coordination

Size: px
Start display at page:

Download "Equipment designated as OFOI is to be Owner Furnished Owner Installed and is shown for reference and coordination"

Transcription

1 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA Equipment designated as OFOI is to be Owner Furnished Owner Installed and is shown for reference and coordination only. ITEM : Quantity: Eighteen () Owner/Operator Existing/Relocated DUNNAGE RACKS, EXISTING/RELOCATED. Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : Quantity: Four () Owner/Operator Existing/Relocated INGREDIENT SHELVING & BINS, EXISTING/RELOCATED. Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : Quantity: Nineteen () Owner/Operator Existing/Relocated STORAGE SHELVING, EXISTING/RELOCATED 0 00-

2 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : Owner/Operator Existing/Relocated HANDSINK, EXISTING/RELOCATED. Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : Owner/Operator Existing/Relocated PREPTABLE & INGREDIENT BINS, EXISTING/RELOCATED. Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : Owner/Operator Existing/Relocated FILE CABINET, EXISTING/RELOCATED. Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : Owner/Operator Existing/Relocated MOBILE WORKTABLE, EXISTING/RELOCATED 0 00-

3 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : DRY STORAGE SHELVING - OFOI Quantity: Six () Metro MetroMax (Q). Length, width and configuration per plan and verified room dimensions.. MetroMax (Q) open grid mat shelving.. " High with five tiers.. Each section shall be free-standing with four legs. ITEM : CATERING STORAGE SHELVING - OFOI Quantity: Fourteen () Metro MetroMax (Q). Length, width and configuration per plan and verified room dimensions.. MetroMax (Q) open grid mat shelving.. " High with five tiers.. Each section shall be free-standing with four legs. ITEM 0: HEATED BANQUET CARTS, EXISTING/RELOCATED Quantity: Six () Owner/Operator Existing/Relocated. Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K

4 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA ITEM : ITEM : INGREDIENT COOLER Bally Refrigerated Boxes Prefabricated Wall Panels. Bally drawing number JE. See Plans for Exact Size and Configuration. Walk-In Cooler to be prefabricated of modular design and construction.. All Walk-In panels shall be provided with an overall thickness of ".. Panels: a. Panels shall consist of interior and exterior metal skins precisely formed with steel dies and roll-form equipment and thoroughly checked with gauges for accuracy. The insulation shall be "Foamed-In Place" (not laminated) and when completely heat-cured, bind tenaciously to the metal skins to form a rigid ", " or " thick insulated panel. Urethane shall be CFC free Enovate 000 (poured, not frothed). To insure tight joints, panel edges must have foamed-in-place tongues and grooves which are of the same density as the rest of the panel. A flexible vinyl gasket, which is also foamed in place (not glued or stapled) shall extend around the interior and exterior perimeter of all tongue edges. Gaskets shall be resistant to damage from oil, fats, water and detergents and must be NSF-approved. b. Foam core of panels shall be Underwriters Laboratories-listed as having flame spread of or lower and smoke generation of 0 or lower when tested in accordance with ASTME-- and certified with a UL Label. Panels shall be approved by Factory Mutual as a Class I building type. They shall be foamed using a high impingement mixing process utilizing Enovate 000 HFC expanding agents (zero ozone depleting). Panels shall be in compliance with the Federal Energy Independence and Security Act of 00 with minimum R-values tested and approved per the code. c. All panels except corner panels shall be made in " and " widths, fully interchangeable for fast, easy assembly. Panels -/", -/" or -/" wide are to be furnished only if required to fit the allocated space. Custom width panels shall be provided to meet non-nominal sizes. To assure perfect alignment and maximum strength, corner panels shall employ a right-angle configuration with exterior horizontal dimensions of " on each side. Vertical panels (except corner panels) shall be supplied in a single length up to ' high (' high for installations with aluminum or stainless steel finish). For outdoor applications, single-height panels greater than ' (' for aluminum) or multi-tiered vertical panels must be secured to horizontal grits mounted between building columns. d. Panels shall be equipped with Bally Speed-Lok diaphragmatic joining devices. The distance between locks shall not exceed ". Each device shall consist of a cam action, hooked locking arm placed in one panel, and a steel rod positioned in the adjoining panel, so that when the arm is rotated, the hook engages the rod and draws the panels tightly together with cam action. Arms and rods shall be housed in individual steel pockets. Pockets on one side of the panel shall be connected to pockets on the other side in width, by the use of "-wide metal straps and foamed-in place. When panels are joined together, these straps shall form lock-to-lock connections for added strength

5 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA Panel Finishes: a. Interior ceiling finish shall be.0" white smooth aluminum. b. Interior walls shall be.0" embossed aluminum pre painted white. c. Exterior finish where exposed to be 0 gauge smooth stainless steel, balance of exterior finish un-exposed to be gauge embossed galvalume. All exterior exposed walls to be finished with two rows of Boston 0 bumper rails set at " and 0" AFF respectively.. Floor Type; Refer to drawings to confirm which of the following floor conditions apply: a. Walk-In floor located on top of floor slab: Provide floor panels with foamed-in-place /" plywood and a.00" rigidized aluminum wearing floor finish. Provide with " deep interior ramp with the same wearing floor surface. Provide floor panels with "super floor" structural reinforcement members foamed in place or equal when doors larger than " wide are provided. Insulated floor panels are to be supplied by panel manufacturer. b. Walk-In floor located in /" floor slab depression: Provide floor panels with foamed-in-place /" plywood and a.00" rigidized aluminum wearing floor finish. Provide floor panels with "super floor" structural reinforcement members foamed in place or equal when doors larger than " wide are provided. Insulated floor panels are to be supplied by panel manufacturer. c. Walk-In floor located in /" floor slab depression: Provide floor panels with.00" smooth aluminum surface. Insulated floor panels are to be supplied by panel manufacturer. Walk-in to be installed in." building floor recess per manufacturer s drawings and topped with topping slab and quarry tile by G.C. Installing Contractor to verify levelness of recess and provide sand and shims as necessary to provide a completely level walk-in floor (as required per manufacturers drawings). Finished floor materials to be as specified by the Architect, and provided and installed by General Contractor. KEC to coordinate door buck, door length and door threshold requirements.. Swing Doors: a. Where swing doors are shown in plan, provide entrance door - sized per plan and frame numbered per plan. Door to be hinged as shown on plan, complete with three hinges. The door to be flush type, constructed and insulated in the same manner as the wall panels, and finished inside and out, to match adjacent walls. Door to be complete with." alumunim tread brite kick plates to " AFF inside and out. b. Three () spring-loaded cam-lift hinges, one () Kason C door latch hardware to have provisions for padlocking and a safety release to prevent entrapment of personnel within the box. c. Provide door section with an LED type vapor-proof light with clear globe and pilot light switch and conduit between switch box and receptacle box. All conduit and wiring to be concealed. d. Door to be complete with heavy-duty Clear-Vu vinyl strip door, heated viewport and door closer. Door buck to be coordinated with finished floor elevation to allow minimum door sweep exposure at threshold interface. Threshold to be constructed of gauge stainless steel " in depth and to be secured in the center of the door threshold reaching " beyond the cooler wall face in and out. Threshold to be secured to floors with stainless steel countersunk fasteners. e. Heated pressure relief port (air-vent) where required (freezer cavity). f. Modularm LC alarm to be included in door section, with remote sensor and adjustable alarm points to indicate the temperature inside, and sound an alarm when the temperature is unsatisfactory. The alarm shall have a mute switch to silence the audible alarm and a reset button to reset the alarm once the temperature conditions are satisfactory. Control wiring to building s alarm system (if applicable) shall be by Electrical Division. Dial thermometers are not allowed. g. Magnetic core gaskets on the top edge and both sides of the door shall keep the door in a closed position, forming a tight seal; a flexible, dual-blade wiper gasket shall be installed at the bottom 0 00-

6 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA of the door. NSF-approved gaskets shall be replaceable. h. Door shall have structural reinforcing type of frame around entire perimeter of the door opening with thermal breaker and reinforcement plates foamed in place for hardware.. Glass Display Doors: a. When shown on the plan, provide maximum number of full height doors as possible in a single framed opening. Doors to be fabricated of polished extruded aluminum frames with pull type door handles, self closing hinges and tempered insulating safety glass. b. Doors, glass, and frames shall be heated to eliminate condensation; temperature/humidity control system to be provided to regulate heated glass. c. Doors to have adjustable closing tension. d. LED lights to be provided at each side of each door for display illumination. Electrical junction boxes shall be provided for 0V PH service. Light fixtures to be suitable for low-temperature operation and to include lamps, shields and pre-wired ballast. e. Each door shall have " deep white epoxy coated, individually adjustable display shelving assembly with six () tiers. f. Number of doors, door swings, and sizes shall be as shown on plan.. LED light fixtures. Provide extra low temperature Kason 0 LED light fixtures with heavy duty tubes for field installation by the Electrical Division. All light fixtures to be U.L. listed for use inside walk-in cooler or freezer. All conduit and wiring between light fixtures to be concealed where possible. Refer to foodservice walk in electrical plan for number and location of light fixtures. Provide lighting inside walk-in to meet or exceed 0 foot candles as measured at " above finish floor.. Fan Control Switch: Provide at entrance of freezer, door time switch toggle and pilot light, to shut blower fan motor of freezer to allow entrance by personnel without fan blowing on them. Use M.H.Rhodes Series #0. 0. Matching finish trim strips, from floor to ceiling, at all exposed vertical edges, corners, and joints to building wall(s). Kitchen Equipment Contractor is responsible for verifying dimensions.. Matching finish closure panels from top of walk-in to finished ceiling, on exposed sides. Kitchen Contractor is responsible for verifying dimensions, and for providing access panels as necessary, verify with Architect.. Unit and all components to be N.S.F. and meet the requirements of N.S.F. Standard #.. For any installation requiring additional ceiling support for equipment above or due to span length, provide self-supporting ceiling structural framework over the top of the walk-in compartment(s), and supported by the walk-in walls.. Verify all dimensions with building conditions for proper fit. Provide maximum size possible to fit available space, using standard panels.. All penetrations to be sealed with approved expandable foam insulation and approved silicone sealant.. Bally Refrigeration Boxes, Inc. is the basis of design. Other acceptable manufacturers include Thermo- Kool, Imperial Manufacturing. - provide with same size and features as basis of design. ITEM : ITEM : COOLER EVAPORATOR COIL - INCLUDED IN REFRIGERATION SYSTEM. COOLER REFRIGERATION SYSTEM Bally Refrigerated Boxes BEHA* 0 00-

7 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA One () pre assembled, remote, R0A, cooler compartment refrigeration system. System to consist of condensing unit (high side assembly) and low profile evaporator coil (low side assembly), evaporator mounting kit, thermostatic expansion valve, pump down cycle kit, solenoid valve, temperature control, sight glass, drier, vibration eliminator, pressure control, crankcase heater, extreme low ambient controls, weatherproof housing, and any accessories necessary for a completely installed and functional system for a cooler box temperature of + to + 0 degrees F. Verify exact installation location with Architect, architectural plans, and site conditions.>contractors certified refrigeration mechanic to install all components supplied with the compressor, as per manufacturer's instructions. Also furnish and install refrigeration lines, insulation, refrigerant and accessories as per manufacturer's instruction's and as required.. System shall be designed for Outdoor operation.. Provide with Semi Hermetic Air Cooled compressor.. Provide " x " x /" (minimum) angle iron welded rack for mounting compressors to wall.. Verify and coordinate dimensions and structural requirements with compressors.. Insall with adequate space between (and around) compressors for proper ventilation and servicing.. Prime coat and paint with a high quality rust preventative primer and paint equal to Rustoleum. Finish color to be flat black.. Bally Refrigeration Boxes, Inc. is the basis of design. Other acceptable manufacturers include Thermo- Kool, Imperial Manufacturing. - provide with same size and features as basis of design. ITEM : Quantity: Three () Owner/Operator Existing/Relocated STORAGE SHELVING, EXISTING/RELOCATED. Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : Quantity: Five () Metro MetroMax (Q) COOLER SHELVING - OFOI. Metro Length, width and configuration per plan and verified walk in cooler dimensions.. MetroMax (Q) open grid mat shelving.. " High with five tiers.. Each section shall be free-standing with four legs.. Each section to have two () #MPX polyurethane swivel casters and two () #MPBX polyurethane casters with brakes

8 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA ITEM : ITEM : ITEM : RATH KEG COOLER Bally Refrigerated Boxes Prefabricated Wall Panels. Bally drawing number JE. See Plans for Exact Size and Configuration. Walk-In Cooler to be prefabricated of modular design and construction.. All Walk-In panels shall be provided with an overall thickness of ".. Panels: a. Panels shall consist of interior and exterior metal skins precisely formed with steel dies and roll-form equipment and thoroughly checked with gauges for accuracy. The insulation shall be "Foamed-In Place" (not laminated) and when completely heat-cured, bind tenaciously to the metal skins to form a rigid ", " or " thick insulated panel. Urethane shall be CFC free Enovate 000 (poured, not frothed). To insure tight joints, panel edges must have foamed-in-place tongues and grooves which are of the same density as the rest of the panel. A flexible vinyl gasket, which is also foamed in place (not glued or stapled) shall extend around the interior and exterior perimeter of all tongue edges. Gaskets shall be resistant to damage from oil, fats, water and detergents and must be NSF-approved. b. Foam core of panels shall be Underwriters Laboratories-listed as having flame spread of or lower and smoke generation of 0 or lower when tested in accordance with ASTME-- and certified with a UL Label. Panels shall be approved by Factory Mutual as a Class I building type. They shall be foamed using a high impingement mixing process utilizing Enovate 000 HFC expanding agents (zero ozone depleting). Panels shall be in compliance with the Federal Energy Independence and Security Act of 00 with minimum R-values tested and approved per the code. c. All panels except corner panels shall be made in " and " widths, fully interchangeable for fast, easy assembly. Panels -/", -/" or -/" wide are to be furnished only if required to fit the allocated space. Custom width panels shall be provided to meet non-nominal sizes. To assure perfect alignment and maximum strength, corner panels shall employ a right-angle configuration with exterior horizontal dimensions of " on each side. Vertical panels (except corner panels) shall be supplied in a single length up to ' high (' high for installations with aluminum or stainless steel finish). For outdoor applications, single-height panels greater than ' (' for aluminum) or multi-tiered vertical panels must be secured to horizontal grits mounted between building columns. d. Panels shall be equipped with Bally Speed-Lok diaphragmatic joining devices. The distance between locks shall not exceed ". Each device shall consist of a cam action, hooked locking arm placed in one panel, and a steel rod positioned in the adjoining panel, so that when the arm is rotated, the hook engages the rod and draws the panels tightly together with cam action. Arms and 0 00-

9 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA rods shall be housed in individual steel pockets. Pockets on one side of the panel shall be connected to pockets on the other side in width, by the use of "-wide metal straps and foamed-in place. When panels are joined together, these straps shall form lock-to-lock connections for added strength.. Panel Finishes: a. Interior ceiling finish shall be.0" white smooth aluminum. b. Interior walls shall be.0" embossed aluminum pre painted white. c. Exterior finish where exposed to be 0 gauge smooth stainless steel, balance of exterior finish un-exposed to be gauge embossed galvalume. All exterior exposed walls to be finished with two rows of Boston 0 bumper rails set at " and 0" AFF respectively.. Floor Type; Refer to drawings to confirm which of the following floor conditions apply: a. Walk-In floor located on top of floor slab: Provide floor panels with foamed-in-place /" plywood and a.00" rigidized aluminum wearing floor finish. Provide with " deep interior ramp with the same wearing floor surface. Provide floor panels with "super floor" structural reinforcement members foamed in place or equal when doors larger than " wide are provided. Insulated floor panels are to be supplied by panel manufacturer. b. Walk-In floor located in /" floor slab depression: Provide floor panels with foamed-in-place /" plywood and a.00" rigidized aluminum wearing floor finish. Provide floor panels with "super floor" structural reinforcement members foamed in place or equal when doors larger than " wide are provided. Insulated floor panels are to be supplied by panel manufacturer. c. Walk-In floor located in /" floor slab depression: Provide floor panels with.00" smooth aluminum surface. Insulated floor panels are to be supplied by panel manufacturer. Walk-in to be installed in." building floor recess per manufacturer s drawings and topped with topping slab and quarry tile by G.C. Installing Contractor to verify levelness of recess and provide sand and shims as necessary to provide a completely level walk-in floor (as required per manufacturers drawings). Finished floor materials to be as specified by the Architect, and provided and installed by General Contractor. KEC to coordinate door buck, door length and door threshold requirements.. Swing Doors: a. Where swing doors are shown in plan, provide entrance door - sized per plan and frame numbered per plan. Door to be hinged as shown on plan, complete with three hinges. The door to be flush type, constructed and insulated in the same manner as the wall panels, and finished inside and out, to match adjacent walls. Door to be complete with." alumunim tread brite kick plates to " AFF inside and out. b. Three () spring-loaded cam-lift hinges, one () Kason C door latch hardware to have provisions for padlocking and a safety release to prevent entrapment of personnel within the box. c. Provide door section with an LED type vapor-proof light with clear globe and pilot light switch and conduit between switch box and receptacle box. All conduit and wiring to be concealed. d. Door to be complete with heavy-duty Clear-Vu vinyl strip door, heated viewport and door closer. Door buck to be coordinated with finished floor elevation to allow minimum door sweep exposure at threshold interface. Threshold to be constructed of gauge stainless steel " in depth and to be secured in the center of the door threshold reaching " beyond the cooler wall face in and out. Threshold to be secured to floors with stainless steel countersunk fasteners. e. Heated pressure relief port (air-vent) where required (freezer cavity). f. Modularm LC alarm to be included in door section, with remote sensor and adjustable alarm points to indicate the temperature inside, and sound an alarm when the temperature is unsatisfactory. The alarm shall have a mute switch to silence the audible alarm and a reset button 0 00-

10 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA to reset the alarm once the temperature conditions are satisfactory. Control wiring to building s alarm system (if applicable) shall be by Electrical Division. Dial thermometers are not allowed. g. Magnetic core gaskets on the top edge and both sides of the door shall keep the door in a closed position, forming a tight seal; a flexible, dual-blade wiper gasket shall be installed at the bottom of the door. NSF-approved gaskets shall be replaceable. h. Door shall have structural reinforcing type of frame around entire perimeter of the door opening with thermal breaker and reinforcement plates foamed in place for hardware.. Glass Display Doors: a. When shown on the plan, provide maximum number of full height doors as possible in a single framed opening. Doors to be fabricated of polished extruded aluminum frames with pull type door handles, self closing hinges and tempered insulating safety glass. b. Doors, glass, and frames shall be heated to eliminate condensation; temperature/humidity control system to be provided to regulate heated glass. c. Doors to have adjustable closing tension. d. LED lights to be provided at each side of each door for display illumination. Electrical junction boxes shall be provided for 0V PH service. Light fixtures to be suitable for low-temperature operation and to include lamps, shields and pre-wired ballast. e. Each door shall have " deep white epoxy coated, individually adjustable display shelving assembly with six () tiers. f. Number of doors, door swings, and sizes shall be as shown on plan.. LED light fixtures. Provide extra low temperature Kason 0 LED light fixtures with heavy duty tubes for field installation by the Electrical Division. All light fixtures to be U.L. listed for use inside walk-in cooler or freezer. All conduit and wiring between light fixtures to be concealed where possible. Refer to foodservice walk in electrical plan for number and location of light fixtures. Provide lighting inside walk-in to meet or exceed 0 foot candles as measured at " above finish floor.. Fan Control Switch: Provide at entrance of freezer, door time switch toggle and pilot light, to shut blower fan motor of freezer to allow entrance by personnel without fan blowing on them. Use M.H.Rhodes Series #0. 0. Matching finish trim strips, from floor to ceiling, at all exposed vertical edges, corners, and joints to building wall(s). Kitchen Equipment Contractor is responsible for verifying dimensions.. Matching finish closure panels from top of walk-in to finished ceiling, on exposed sides. Kitchen Contractor is responsible for verifying dimensions, and for providing access panels as necessary, verify with Architect.. Unit and all components to be N.S.F. and meet the requirements of N.S.F. Standard #.. For any installation requiring additional ceiling support for equipment above or due to span length, provide self-supporting ceiling structural framework over the top of the walk-in compartment(s), and supported by the walk-in walls.. Verify all dimensions with building conditions for proper fit. Provide maximum size possible to fit available space, using standard panels.. All penetrations to be sealed with approved expandable foam insulation and approved silicone sealant.. Bally Refrigeration Boxes, Inc. is the basis of design. Other acceptable manufacturers include Thermo- Kool, Imperial Manufacturing. - provide with same size and features as basis of design. ITEM 0: ITEM : COOLER EVAPORATOR COIL - INCLUDED IN REFRIGERATION SYSTEM. COOLER REFRIGERATION SYSTEM 0 00-

11 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA Bally Refrigerated Boxes BEHA*. One () pre assembled, remote, R0A, cooler compartment refrigeration system. System to consist of condensing unit (high side assembly) and low profile evaporator coil (low side assembly), evaporator mounting kit, thermostatic expansion valve, pump down cycle kit, solenoid valve, temperature control, sight glass, drier, vibration eliminator, pressure control, crankcase heater, extreme low ambient controls, weatherproof housing, and any accessories necessary for a completely installed and functional system for a cooler box temperature of + to + 0 degrees F. Verify exact installation location with Architect, architectural plans, and site conditions.>contractors certified refrigeration mechanic to install all components supplied with the compressor, as per manufacturer's instructions. Also furnish and install refrigeration lines, insulation, refrigerant and accessories as per manufacturer's instruction's and as required.. System shall be designed for Outdoor operation.. Provide with Semi Hermetic Air Cooled compressor.. Provide " x " x /" (minimum) angle iron welded rack for mounting compressors to wall.. Verify and coordinate dimensions and structural requirements with compressors.. Insall with adequate space between (and around) compressors for proper ventilation and servicing.. Prime coat and paint with a high quality rust preventative primer and paint equal to Rustoleum. Finish color to be flat black.. Bally Refrigeration Boxes, Inc. is the basis of design. Other acceptable manufacturers include Thermo- Kool, Imperial Manufacturing. - provide with same size and features as basis of design. ITEM : ITEM : ITEM : WALK-IN FREEZER Bally Refrigerated Boxes Prefabricated Wall Panels. Bally drawing number JE. See Plans for Exact Size and Configuration. Walk-In Freezer to be prefabricated of modular design and construction.. All Walk-In panels shall be provided with an overall thickness of ".. Panels: a. Panels shall consist of interior and exterior metal skins precisely formed with steel dies and roll-form equipment and thoroughly checked with gauges for accuracy. The insulation shall be "Foamed-In Place" (not laminated) and when completely heat-cured, bind tenaciously to the metal 0 00-

12 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA skins to form a rigid ", " or " thick insulated panel. Urethane shall be CFC free Enovate 000 (poured, not frothed). To insure tight joints, panel edges must have foamed-in-place tongues and grooves which are of the same density as the rest of the panel. A flexible vinyl gasket, which is also foamed in place (not glued or stapled) shall extend around the interior and exterior perimeter of all tongue edges. Gaskets shall be resistant to damage from oil, fats, water and detergents and must be NSF-approved. b. Foam core of panels shall be Underwriters Laboratories-listed as having flame spread of or lower and smoke generation of 0 or lower when tested in accordance with ASTME-- and certified with a UL Label. Panels shall be approved by Factory Mutual as a Class I building type. They shall be foamed using a high impingement mixing process utilizing Enovate 000 HFC expanding agents (zero ozone depleting). Panels shall be in compliance with the Federal Energy Independence and Security Act of 00 with minimum R-values tested and approved per the code. c. All panels except corner panels shall be made in " and " widths, fully interchangeable for fast, easy assembly. Panels -/", -/" or -/" wide are to be furnished only if required to fit the allocated space. Custom width panels shall be provided to meet non-nominal sizes. To assure perfect alignment and maximum strength, corner panels shall employ a right-angle configuration with exterior horizontal dimensions of " on each side. Vertical panels (except corner panels) shall be supplied in a single length up to ' high (' high for installations with aluminum or stainless steel finish). For outdoor applications, single-height panels greater than ' (' for aluminum) or multi-tiered vertical panels must be secured to horizontal grits mounted between building columns. d. Panels shall be equipped with Bally Speed-Lok diaphragmatic joining devices. The distance between locks shall not exceed ". Each device shall consist of a cam action, hooked locking arm placed in one panel, and a steel rod positioned in the adjoining panel, so that when the arm is rotated, the hook engages the rod and draws the panels tightly together with cam action. Arms and rods shall be housed in individual steel pockets. Pockets on one side of the panel shall be connected to pockets on the other side in width, by the use of "-wide metal straps and foamed-in place. When panels are joined together, these straps shall form lock-to-lock connections for added strength.. Panel Finishes: a. Interior ceiling finish shall be.0" white smooth aluminum. b. Interior walls shall be.0" embossed aluminum pre painted white. c. Exterior finish where exposed to be 0 gauge smooth stainless steel, balance of exterior finish un-exposed to be gauge embossed galvalume. All exterior exposed walls to be finished with two rows of Boston 0 bumper rails set at " and 0" AFF respectively.. Floor Type; Refer to drawings to confirm which of the following floor conditions apply: a. Walk-In floor located on top of floor slab: Provide floor panels with foamed-in-place /" plywood and a.00" rigidized aluminum wearing floor finish. Provide with " deep interior ramp with the same wearing floor surface. Provide floor panels with "super floor" structural reinforcement members foamed in place or equal when doors larger than " wide are provided. Insulated floor panels are to be supplied by panel manufacturer. b. Walk-In floor located in /" floor slab depression: Provide floor panels with foamed-in-place /" plywood and a.00" rigidized aluminum wearing floor finish. Provide floor panels with "super floor" structural reinforcement members foamed in place or equal when doors larger than " wide are provided. Insulated floor panels are to be supplied by panel manufacturer. c. Walk-In floor located in /" floor slab depression: Provide floor panels with.00" smooth aluminum surface. Insulated floor panels are to be 0 00-

13 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA supplied by panel manufacturer. Walk-in to be installed in." building floor recess per manufacturer s drawings and topped with topping slab and quarry tile by G.C. Installing Contractor to verify levelness of recess and provide sand and shims as necessary to provide a completely level walk-in floor (as required per manufacturers drawings). Finished floor materials to be as specified by the Architect, and provided and installed by General Contractor. KEC to coordinate door buck, door length and door threshold requirements.. Swing Doors: a. Where swing doors are shown in plan, provide entrance door - sized per plan and frame numbered per plan. Door to be hinged as shown on plan, complete with three hinges. The door to be flush type, constructed and insulated in the same manner as the wall panels, and finished inside and out, to match adjacent walls. Door to be complete with." alumunim tread brite kick plates to " AFF inside and out. b. Three () spring-loaded cam-lift hinges, one () Kason C door latch hardware to have provisions for padlocking and a safety release to prevent entrapment of personnel within the box. c. Provide door section with an LED type vapor-proof light with clear globe and pilot light switch and conduit between switch box and receptacle box. All conduit and wiring to be concealed. d. Door to be complete with heavy-duty Clear-Vu vinyl strip door, heated viewport and door closer. Door buck to be coordinated with finished floor elevation to allow minimum door sweep exposure at threshold interface. Threshold to be constructed of gauge stainless steel " in depth and to be secured in the center of the door threshold reaching " beyond the cooler wall face in and out. Threshold to be secured to floors with stainless steel countersunk fasteners. e. Heated pressure relief port (air-vent) where required (freezer cavity). f. Modularm LC alarm to be included in door section, with remote sensor and adjustable alarm points to indicate the temperature inside, and sound an alarm when the temperature is unsatisfactory. The alarm shall have a mute switch to silence the audible alarm and a reset button to reset the alarm once the temperature conditions are satisfactory. Control wiring to building s alarm system (if applicable) shall be by Electrical Division. Dial thermometers are not allowed. g. Magnetic core gaskets on the top edge and both sides of the door shall keep the door in a closed position, forming a tight seal; a flexible, dual-blade wiper gasket shall be installed at the bottom of the door. NSF-approved gaskets shall be replaceable. h. Door shall have structural reinforcing type of frame around entire perimeter of the door opening with thermal breaker and reinforcement plates foamed in place for hardware.. Glass Display Doors: a. When shown on the plan, provide maximum number of full height doors as possible in a single framed opening. Doors to be fabricated of polished extruded aluminum frames with pull type door handles, self closing hinges and tempered insulating safety glass. b. Doors, glass, and frames shall be heated to eliminate condensation; temperature/humidity control system to be provided to regulate heated glass. c. Doors to have adjustable closing tension. d. LED lights to be provided at each side of each door for display illumination. Electrical junction boxes shall be provided for 0V PH service. Light fixtures to be suitable for low-temperature operation and to include lamps, shields and pre-wired ballast. e. Each door shall have " deep white epoxy coated, individually adjustable display shelving assembly with six () tiers. f. Number of doors, door swings, and sizes shall be as shown on plan.. LED light fixtures. Provide extra low temperature Kason 0 LED light fixtures with heavy duty tubes for field installation by the Electrical Division. All light fixtures to be U.L. listed for use inside walk-in cooler or freezer. All conduit and wiring between light fixtures to be concealed where possible. Refer to foodservice walk in electrical plan for number and location of light fixtures. Provide lighting inside 0 00-

14 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA walk-in to meet or exceed 0 foot candles as measured at " above finish floor.. Fan Control Switch: Provide at entrance of freezer, door time switch toggle and pilot light, to shut blower fan motor of freezer to allow entrance by personnel without fan blowing on them. Use M.H.Rhodes Series #0. 0. Matching finish trim strips, from floor to ceiling, at all exposed vertical edges, corners, and joints to building wall(s). Kitchen Equipment Contractor is responsible for verifying dimensions.. Matching finish closure panels from top of walk-in to finished ceiling, on exposed sides. Kitchen Contractor is responsible for verifying dimensions, and for providing access panels as necessary, verify with Architect.. Unit and all components to be N.S.F. and meet the requirements of N.S.F. Standard #.. For any installation requiring additional ceiling support for equipment above or due to span length, provide self-supporting ceiling structural framework over the top of the walk-in compartment(s), and supported by the walk-in walls.. Verify all dimensions with building conditions for proper fit. Provide maximum size possible to fit available space, using standard panels.. All penetrations to be sealed with approved expandable foam insulation and approved silicone sealant.. Bally Refrigeration Boxes, Inc. is the basis of design. Other acceptable manufacturers include Thermo- Kool, Imperial Manufacturing. - provide with same size and features as basis of design. ITEM : ITEM : FREEZER EVAPORATOR COIL - INCLUDED IN REFRIGERATION SYSTEM. FREEZER REFRIGERATION SYSTEM Bally Refrigerated Boxes BEZA*. One () pre assembled, remote, R0A, freezer compartment refrigeration system. System to consist of condensing unit (high side assembly) and low profile evaporator coil (low side assembly), evaporator mounting kit, automatic electric defrost system, time clock, thermostatic expansion valve, pump down cycle kit, solenoid valve, temperature control, sight glass, drier, vibration eliminator, pressure control, crankcase heater, extreme low ambient controls, weatherproof housing, and any accessories necessary for a completely installed and functional system for a freezer box temperature of -0 to - degrees F. Verify exact installation location with Architect, architectural plans, and site conditions.>contractor's certified refrigeration mechanic to install all components supplied with the compressor, as per manufacturer's instructions. Also furnish and install refrigeration lines, insulation, refrigerant, drain line heater kit and insulation, and accessories as per manufacturer's instruction's and as required.. System shall be designed for Outdoor operation.. Provide with Semi Hermetic Air Cooled compressor.. Provide " x " x /" (minimum) angle iron welded rack for mounting compressors to wall.. Verify and coordinate dimensions and structural requirements with compressors.. Insall with adequate space between (and around) compressors for proper ventilation and servicing.. Prime coat and paint with a high quality rust preventative primer and paint equal to Rustoleum. Finish color to be flat black

15 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA Bally Refrigeration Boxes, Inc. is the basis of design. Other acceptable manufacturers include Thermo- Kool, Imperial Manufacturing. - provide with same size and features as basis of design. ITEM : Quantity: Twenty (0) Metro MetroMax (Q) FREEZER SHELVING - OFOI. Metro Length, width and configuration per plan and verified walk in freezer dimensions.. MetroMax (Q) Open Grid Mat Shelving.. " High With Five Tiers.. Each section shall be free-standing with four legs.. Each section to have two () #MPX polyurethane swivel casters and two () #MPBX polyurethane casters with brakes. ITEM : Quantity: Three () Owner/Operator Existing/Relocated DUNNAGE RACKS, EXISTING/RELOCATED. Renovate and relocate per plans and Section 000, Article. Existing Equipment, Paragraphs A through K. ITEM : ITEM 0: ITEM : MEAT WALK-IN COOLER Bally Refrigerated Boxes Prefabricated Wall Panels. Bally drawing number JE. See Plans for Exact Size and Configuration. Walk-In Cooler to be 0 00-

16 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA prefabricated of modular design and construction.. All Walk-In panels shall be provided with an overall thickness of ".. Panels: a. Panels shall consist of interior and exterior metal skins precisely formed with steel dies and roll-form equipment and thoroughly checked with gauges for accuracy. The insulation shall be "Foamed-In Place" (not laminated) and when completely heat-cured, bind tenaciously to the metal skins to form a rigid ", " or " thick insulated panel. Urethane shall be CFC free Enovate 000 (poured, not frothed). To insure tight joints, panel edges must have foamed-in-place tongues and grooves which are of the same density as the rest of the panel. A flexible vinyl gasket, which is also foamed in place (not glued or stapled) shall extend around the interior and exterior perimeter of all tongue edges. Gaskets shall be resistant to damage from oil, fats, water and detergents and must be NSF-approved. b. Foam core of panels shall be Underwriters Laboratories-listed as having flame spread of or lower and smoke generation of 0 or lower when tested in accordance with ASTME-- and certified with a UL Label. Panels shall be approved by Factory Mutual as a Class I building type. They shall be foamed using a high impingement mixing process utilizing Enovate 000 HFC expanding agents (zero ozone depleting). Panels shall be in compliance with the Federal Energy Independence and Security Act of 00 with minimum R-values tested and approved per the code. c. All panels except corner panels shall be made in " and " widths, fully interchangeable for fast, easy assembly. Panels -/", -/" or -/" wide are to be furnished only if required to fit the allocated space. Custom width panels shall be provided to meet non-nominal sizes. To assure perfect alignment and maximum strength, corner panels shall employ a right-angle configuration with exterior horizontal dimensions of " on each side. Vertical panels (except corner panels) shall be supplied in a single length up to ' high (' high for installations with aluminum or stainless steel finish). For outdoor applications, single-height panels greater than ' (' for aluminum) or multi-tiered vertical panels must be secured to horizontal grits mounted between building columns. d. Panels shall be equipped with Bally Speed-Lok diaphragmatic joining devices. The distance between locks shall not exceed ". Each device shall consist of a cam action, hooked locking arm placed in one panel, and a steel rod positioned in the adjoining panel, so that when the arm is rotated, the hook engages the rod and draws the panels tightly together with cam action. Arms and rods shall be housed in individual steel pockets. Pockets on one side of the panel shall be connected to pockets on the other side in width, by the use of "-wide metal straps and foamed-in place. When panels are joined together, these straps shall form lock-to-lock connections for added strength.. Panel Finishes: a. Interior ceiling finish shall be.0" white smooth aluminum. b. Interior walls shall be.0" embossed aluminum pre painted white. c. Exterior finish where exposed to be 0 gauge smooth stainless steel, balance of exterior finish un-exposed to be gauge embossed galvalume. All exterior exposed walls to be finished with two rows of Boston 0 bumper rails set at " and 0" AFF respectively.. Floor Type; Refer to drawings to confirm which of the following floor conditions apply: a. Walk-In floor located on top of floor slab: Provide floor panels with foamed-in-place /" plywood and a.00" rigidized aluminum wearing floor finish. Provide with " deep interior ramp with the same wearing floor surface. Provide floor panels with "super floor" structural reinforcement members foamed in place or equal when doors larger than " wide are provided. Insulated floor panels are to be supplied by panel manufacturer. b. Walk-In floor located in /" floor slab depression: 0 00-

17 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA Provide floor panels with foamed-in-place /" plywood and a.00" rigidized aluminum wearing floor finish. Provide floor panels with "super floor" structural reinforcement members foamed in place or equal when doors larger than " wide are provided. Insulated floor panels are to be supplied by panel manufacturer. c. Walk-In floor located in /" floor slab depression: Provide floor panels with.00" smooth aluminum surface. Insulated floor panels are to be supplied by panel manufacturer. Walk-in to be installed in." building floor recess per manufacturer s drawings and topped with topping slab and quarry tile by G.C. Installing Contractor to verify levelness of recess and provide sand and shims as necessary to provide a completely level walk-in floor (as required per manufacturers drawings). Finished floor materials to be as specified by the Architect, and provided and installed by General Contractor. KEC to coordinate door buck, door length and door threshold requirements.. Swing Doors: a. Where swing doors are shown in plan, provide entrance door - sized per plan and frame numbered per plan. Door to be hinged as shown on plan, complete with three hinges. The door to be flush type, constructed and insulated in the same manner as the wall panels, and finished inside and out, to match adjacent walls. Door to be complete with." alumunim tread brite kick plates to " AFF inside and out. b. Three () spring-loaded cam-lift hinges, one () Kason C door latch hardware to have provisions for padlocking and a safety release to prevent entrapment of personnel within the box. c. Provide door section with an LED type vapor-proof light with clear globe and pilot light switch and conduit between switch box and receptacle box. All conduit and wiring to be concealed. d. Door to be complete with heavy-duty Clear-Vu vinyl strip door, heated viewport and door closer. Door buck to be coordinated with finished floor elevation to allow minimum door sweep exposure at threshold interface. Threshold to be constructed of gauge stainless steel " in depth and to be secured in the center of the door threshold reaching " beyond the cooler wall face in and out. Threshold to be secured to floors with stainless steel countersunk fasteners. e. Heated pressure relief port (air-vent) where required (freezer cavity). f. Modularm LC alarm to be included in door section, with remote sensor and adjustable alarm points to indicate the temperature inside, and sound an alarm when the temperature is unsatisfactory. The alarm shall have a mute switch to silence the audible alarm and a reset button to reset the alarm once the temperature conditions are satisfactory. Control wiring to building s alarm system (if applicable) shall be by Electrical Division. Dial thermometers are not allowed. g. Magnetic core gaskets on the top edge and both sides of the door shall keep the door in a closed position, forming a tight seal; a flexible, dual-blade wiper gasket shall be installed at the bottom of the door. NSF-approved gaskets shall be replaceable. h. Door shall have structural reinforcing type of frame around entire perimeter of the door opening with thermal breaker and reinforcement plates foamed in place for hardware.. Glass Display Doors: a. When shown on the plan, provide maximum number of full height doors as possible in a single framed opening. Doors to be fabricated of polished extruded aluminum frames with pull type door handles, self closing hinges and tempered insulating safety glass. b. Doors, glass, and frames shall be heated to eliminate condensation; temperature/humidity control system to be provided to regulate heated glass. c. Doors to have adjustable closing tension. d. LED lights to be provided at each side of each door for display illumination. Electrical junction boxes shall be provided for 0V PH service. Light fixtures to be suitable for low-temperature operation and to include lamps, shields and pre-wired ballast. e. Each door shall have " deep white epoxy coated, individually adjustable display shelving 0 00-

18 Wisconsin Union Redevelopment Project Phase II/Alumni Park March, 0 U/WA assembly with six () tiers. f. Number of doors, door swings, and sizes shall be as shown on plan.. LED light fixtures. Provide extra low temperature Kason 0 LED light fixtures with heavy duty tubes for field installation by the Electrical Division. All light fixtures to be U.L. listed for use inside walk-in cooler or freezer. All conduit and wiring between light fixtures to be concealed where possible. Refer to foodservice walk in electrical plan for number and location of light fixtures. Provide lighting inside walk-in to meet or exceed 0 foot candles as measured at " above finish floor.. Fan Control Switch: Provide at entrance of freezer, door time switch toggle and pilot light, to shut blower fan motor of freezer to allow entrance by personnel without fan blowing on them. Use M.H.Rhodes Series #0. 0. Matching finish trim strips, from floor to ceiling, at all exposed vertical edges, corners, and joints to building wall(s). Kitchen Equipment Contractor is responsible for verifying dimensions.. Matching finish closure panels from top of walk-in to finished ceiling, on exposed sides. Kitchen Contractor is responsible for verifying dimensions, and for providing access panels as necessary, verify with Architect.. Unit and all components to be N.S.F. and meet the requirements of N.S.F. Standard #.. For any installation requiring additional ceiling support for equipment above or due to span length, provide self-supporting ceiling structural framework over the top of the walk-in compartment(s), and supported by the walk-in walls.. Verify all dimensions with building conditions for proper fit. Provide maximum size possible to fit available space, using standard panels.. All penetrations to be sealed with approved expandable foam insulation and approved silicone sealant.. Bally Refrigeration Boxes, Inc. is the basis of design. Other acceptable manufacturers include Thermo- Kool, Imperial Manufacturing. - provide with same size and features as basis of design. ITEM : COOLER EVAPORATOR COIL - INCLUDED IN REFRIGERATION SYSTEM. ITEM : COOLER REFRIGERATION SYSTEM Bally Refrigerated Boxes BEHA*. One () pre assembled, remote, R0A, cooler compartment refrigeration system. System to consist of condensing unit (high side assembly) and low profile evaporator coil (low side assembly), evaporator mounting kit, thermostatic expansion valve, pump down cycle kit, solenoid valve, temperature control, sight glass, drier, vibration eliminator, pressure control, crankcase heater, extreme low ambient controls, weatherproof housing, and any accessories necessary for a completely installed and functional system for a cooler box temperature of + to + 0 degrees F. Verify exact installation location with Architect, architectural plans, and site conditions.>contractors certified refrigeration mechanic to install all components supplied with the compressor, as per manufacturer's instructions. Also furnish and install refrigeration lines, insulation, refrigerant and accessories as per manufacturer's instruction's and as required.. System shall be designed for Outdoor operation

SPECIFICATION GUIDE BALLY

SPECIFICATION GUIDE BALLY SPECIFICATION GUIDE 1-800-24BALLY www.ballyrefboxes.com sales@ballync.com Trade Approvals Underwriters Laboratories (UL): Bally Refrigerated Boxes, Inc. 4, 5, and 6 panels generated a flame spread of 25

More information

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4290 FAX www.norlake.com Kold Locker Walk-Ins Standard

More information

SECTION ACCORDION FOLDING PARTITIONS

SECTION ACCORDION FOLDING PARTITIONS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 22 26.13 ACCORDION FOLDING PARTITIONS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Series 3000 Pocket Doors

Series 3000 Pocket Doors Series 3000 Pocket Doors Introduction: The following three (3) part specification offers the Standard and Optional features for the Series 3000 Pocket Doors. The yellow highlighted areas in the specification

More information

Pre-Engineered Walk-In Coolers and Freezers. Installation Manual

Pre-Engineered Walk-In Coolers and Freezers. Installation Manual Pre-Engineered Walk-In Coolers and Freezers Installation Manual Part One: The Bally Walk-In 1. Preparation for Installing the Walk-In 3 2. Operation of the Bally Speed-Lok 3 Part Two: Installation 1. Positioning

More information

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? SECTION 08360 SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Glazed Aluminum

More information

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter

More information

INC Pre-Assembled Structures

INC Pre-Assembled Structures INC Pre-Assembled Structures Drop-In In-Place Noise Control Pre-Engineered Factory Finished High Performance Rugged Durability INC pre-assembled structures offer a high performance, cost-effective alternative

More information

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work. SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

A. Submit the following in addition to the standard requirements.

A. Submit the following in addition to the standard requirements. SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,

More information

TABLE OF CONTENTS. Subject Paragraph# Page. Introduction Why Nor-Lake? Letter from the President How to Use the Specification Manual

TABLE OF CONTENTS. Subject Paragraph# Page. Introduction Why Nor-Lake? Letter from the President How to Use the Specification Manual TABLE OF CONTENTS Subject Paragraph# Page Introduction Why Nor-Lake? Letter from the President How to Use the Specification Manual i ii iii Part 1 - General Summary 1.01 13038-1 Submittals 1.02 13038-2

More information

Modular Buildings. Installation Manual

Modular Buildings. Installation Manual Modular Buildings Installation Manual 1. Introduction 2 2. Marking Installation Area 2 3. Speed-Lok Operation 2 4. 'Z' Base Trim 3 5. Less Floor Walk-Ins 3 6. Floor Panel Installation 4 7. With-Floor Installation

More information

University Apartments on Brooklyn PROJECT MANUAL

University Apartments on Brooklyn PROJECT MANUAL Section 122100 Horizontal Louver Blinds University Apartments on Brooklyn PART 1 - GENERAL 1.1 SECTION INCLUDES A. Horizontal slat louver blinds. B. Operating hardware. 1.2 RELATED SECTIONS A. Section

More information

2000 POCKET DOOR TECHNICAL DATA

2000 POCKET DOOR TECHNICAL DATA 2000 POCKET DOOR TECHNICAL DATA KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 2000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 10505 - METAL STUDENT LOCKERS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc. P a g e 1 PART I. GENERAL 1.01 Scope A. Furnish and install SoftWalls HIGH-TENSION Acoustical & Tackable Stretch Fabric Systems B. Related Work Specified Elsewhere: 1.Preparation of a smooth, flat and

More information

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION IMPACT RESISTANT WALL PROTECTION SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,

More information

Aluminum-Framed Entrances and Storefronts

Aluminum-Framed Entrances and Storefronts University of New Hampshire University of New Hampshire Scholars' Repository Division 08 Openings Chapter 5 Technical Construction and Renovation Standards 1-25-2013 084113 - Aluminum-Framed Entrances

More information

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM) SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM) Construction Criteria The unit costs for the Physical Fitness Center (Exercise Room) space type are based on the construction quality and design features in

More information

3000 SERIES POCKET DOOR

3000 SERIES POCKET DOOR 3000 SERIES POCKET DOOR KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 3000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose

More information

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS SECTION 08 32 20 CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS Page 1 of 6 USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY,

More information

G. UNDERWRITERS LABORATORY, INC.: 1. UL 325: Electrical Door, Drapery, Gate, Louver, and Window Operators and Systems

G. UNDERWRITERS LABORATORY, INC.: 1. UL 325: Electrical Door, Drapery, Gate, Louver, and Window Operators and Systems B6.0 DIVISION 8 - DOORS AND WINDOWS SECTION 08460 - AUTOMATIC ENTRANCE DOORS Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section numbers and titles

More information

Section BUILDINGS, SHELTERS, ENCLOSURES

Section BUILDINGS, SHELTERS, ENCLOSURES Section 13121 BUILDINGS, SHELTERS, ENCLOSURES Part 1 GENERAL 1.1 SECTION INCLUDES 1.2 A. Pre-engineered buildings. B. Pre-engineered shelters. C. Pre-engineered enclosures. D. Electrical wiring and devices

More information

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM Page 1 of 6 SECTION 08 32 20 LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED GLASS SLIDING DOORS. SECTION INCLUDES OVERHEAD SLIDING TUBE ASSEMBLY, MOUNTING

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA1 Ultra Acoustical, STC 45/46, Omni, Glass Wall PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional s Manually Operated Maximum Opening Height: 12'

More information

Architectural Specifications, Section Phenolic Lockers

Architectural Specifications, Section Phenolic Lockers Architectural Specifications, Section 10500 Phenolic Lockers Hollman, Inc., 1825 W. Walnut Hill Lane, Irving, TX 75038, (972) 815-4000, www.hollman.com 1.0 GENERAL 1.1 SECTION INCLUDES A. Phenolic Lockers.

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

Division 08 OPENINGS TABLE OF CONTENTS

Division 08 OPENINGS TABLE OF CONTENTS Division 08 OPENINGS TABLE OF CONTENTS 08 1000 GENERAL... 2 A. RELATED DIVISIONS... 2 B. GENERAL... 2 08 1000 DOORS AND FRAMES... 2... 2 B. EXTERIOR DOORS AND FRAMES... 2 C. DOOR FRAMES... 2 D. HOLLOW

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-11 41 11 (August 2017) ----------------------------- Preparing Activity: NAVFAC Superseding UFGS-11 41 11 (February 2016) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PRODUCT OVERVIEW: Top Supported Center Stack Paired s Manually Operated Maximum Opening Height: 12' 2 [3.7m] Maximum

More information

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

SPACE TYPE: OUTSIDE PARKING (STRUCTURE) SPACE TYPE: OUTSIDE PARKING (STRUCTURE) Construction Criteria The unit costs for Outside Parking (Structure) space types are based on the construction quality and design features in the following table.

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8 SLIDING WINDOW PAGE 1 PAGE 1 SPECIFICATIONS GENERAL Sliding windows shall be Marlin series #3500-HC (thermally improved) as manufactured by Marlin windows, and shall conform to ANSI/AAMA 101-88 HS-HC40. Series #3500 shall have

More information

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,

More information

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features DESIGN CRITERIA FOR STANDARD CONSTRUCTION: These standard design elements of the P.E.I. Power Equipment Center are utilized to meet the following design criteria per ASCE 7-05 as adopted by the IBC (International

More information

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16 long / 1/2 thick or 16 oz. copper Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)

More information

INSTALLATION/MAINTENANCE MANUAL FOR WALK-IN COOLERS/FREEZERS

INSTALLATION/MAINTENANCE MANUAL FOR WALK-IN COOLERS/FREEZERS INSTALLATION/MAINTENANCE MANUAL FOR WALK-IN COOLERS/FREEZERS THERMO-KOOL/MID-SOUTH INDUSTRIES, INC. 723 East 21st Street, Laurel MS 39440 Phone: (601) 649-4600 Fax: (601) 649-0558 THERMO-KOOL/Mid-South

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME SECTION 08331 OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

Series - 1

Series - 1 SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS DIVISION 10 SPECIALTIES SECTION 10 22 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SPACE TYPE: ENHANCED OFFICE

SPACE TYPE: ENHANCED OFFICE SPACE TYPE: ENHANCED OFFICE Construction Criteria The unit costs for Enhanced Office space types are based on the construction quality and design features in the following table. This information has been

More information

SECTION ROOF ACCESSORIES

SECTION ROOF ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 72 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors 2000/2100/2200 Series Heavy Commercial Sliding Patio Doors MANKO WINDOW SYSTEMS, INC. 800 HAYES DRIVE MANHATTAN, KANSAS 66502 PHONE: (800) 642-1488 (785) 776-9643 FAX: (800) 576-2656 (785) 776-9644 MANKO

More information

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1 GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials, and services to furnish and install VERSA SHIELD Window

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

Vinyl Windows and Doors

Vinyl Windows and Doors Install Atrium 0UZ[PSS *VUÄKLUJL Vinyl Windows and Doors Atrium Vinyl Windows A Commitment to Excellence Since 1948 Welcome the beauty of The Vinyl Advantage Vinyl is the ideal material for engineering

More information

PH6000. Key Features

PH6000. Key Features Phenolic Locker Series PH6000 Key Features ½ inch doors and end panels Durable, backed by a 20 year warranty. Ideal choice for wet-use areas including pools and recreation centers Graffiti resistant, permanent

More information

DIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations

DIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations DIVISION 11 - EQUIPMENT 11400 FOOD SERVICE EQUIPMENT A. Design Considerations 1. The A/E shall use the services of a food service equipment specialist in preparation of kitchen areas and other food preparation

More information

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM Form 15 Work Write-Up Owner-Builder Applicant Owner-Builder Co-Applicant Physical Address: City,

More information

Model 4010 Individual Panels / Curve & Diverter

Model 4010 Individual Panels / Curve & Diverter Model 4010 Individual Panels / Curve & Diverter Introduction: The following three (3) part specification offers the Standard and Optional features for the Model 4010 Curve & Diverter Operable Wall System.

More information

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following: SECTION 10501 PERSONNEL DUTY LOCKERS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 specifications

More information

Key Features. Glass Locker Series GL5000. ¼ inch tempered glass doors with soft closing hinges. Back-painted glass can be matched to any Pantone color

Key Features. Glass Locker Series GL5000. ¼ inch tempered glass doors with soft closing hinges. Back-painted glass can be matched to any Pantone color Glass Locker Series GL5000 Key Features ¼ inch tempered glass doors with soft closing hinges Back-painted glass can be matched to any Pantone color Low iron glass for ultra-clear, pure colors Wood locker

More information

Architectural Details. Walls. Including PVC cove, UL Listed Raceway, & Integration to Flooring. AES Pharma Wall & Walk-On Ceiling Cleanroom System

Architectural Details. Walls. Including PVC cove, UL Listed Raceway, & Integration to Flooring. AES Pharma Wall & Walk-On Ceiling Cleanroom System Architectural Details Section One Walls Including PVC cove, UL Listed Raceway, & Integration to Flooring AES Pharma Wall & Walk-On Ceiling Cleanroom System Architectural Components AES PHARMA SYSTEM AES

More information

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation. SECTION 08462 - SWINGING AUTOMATIC ENTRANCE DOORS PART 1 - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division

More information

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES

MODEL: SIGHT-LINE- COMMAND CENTER CONSOLES 2015 WINSTED CORPORATION 1) GENERAL DESCRIPTION 1.1 Sight-Line Command Center Consoles. SeeAppendix A - C for typical styles and measurements. 1.2 The contractor shall supply a system capable of supporting

More information

The following item to be added to this proposal: Item 38 1 each Serving Line for Lamar Elementary (see attached description) $

The following item to be added to this proposal: Item 38 1 each Serving Line for Lamar Elementary (see attached description) $ Amarillo Independent School District 7200 Interstate 40 West Amarillo, TX 79106-2598 Fax (806) 354-4363 April 15, 2014 ADDENDUM #1 To Request for Proposals for Kitchen Equipment Opening Date: April 25,

More information

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Part 1 General 1. RELATED SECTIONS 1. Section 07 92 10 Joint Sealing 2. Section 08 71 00 Door Hardware 2. REFERENCES 1. American Society

More information

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

Acousti-Seal Encore Paired Panel (10650) Operable Partitions Acousti-Seal Encore Paired Panel 10 22 26 (10650) Operable Partitions Optimal choice for straight-line openings that do not require multiple locations or offset storage Panels are hinged together in groups

More information

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING 7160 Krick Rd., Walton Hills, OH 44146 800-321-3827 - Tel 440-439-8650 - Fax 440-439-6889 SECTION 12 48 16 ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING PART 1. GENERAL 1.01 SUMMARY: This section includes

More information

INSULATED PANEL OVERVIEW

INSULATED PANEL OVERVIEW INSULATED PANEL OVERVIEW Our various series of wall and roof panels are filled with non CFC polyisocyanurate foam. The panels are manufactured in a uniform pressure laminating process that bonds metal

More information

SECTION RESILIENT SHEET FLOORING

SECTION RESILIENT SHEET FLOORING SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.

More information

HD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator

HD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator HORTON AUTOMATICS - ARCHITECTURAL SPECIFICATIONS, 1/2008 HD-Swing Series 4000 Heavy Duty Aluminum Swing Door System with Electric Operator DIVISION 08 - OPENINGS SECTION 08 42 29.33 SWINGING AUTOMATIC

More information

Section SECTIONAL INSULATED STEEL DOORS

Section SECTIONAL INSULATED STEEL DOORS 1 GENERAL 1.1 GENERAL REQUIREMENTS General Conditions and Division 01 apply to this section. 1.2 RELATED WORK Section 05500: Miscellaneous Metal Fabrication Section 07900: Joint Sealers Section 09900:

More information

Utility Cabinet System (UCS)

Utility Cabinet System (UCS) (UCS) The Ultimate in Stainless Steel Modular Walls UCS: Eliminates the need and the costs of constructing a traditional wall Provides easier access and faster installation of the utilities compared to

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 12 2113 - LOUVER BLINDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Division 11 - Equipment Section 11401

Division 11 - Equipment Section 11401 PART 1 - GENERAL 1.1 GENERAL A. Division 1 General Requirements applies and becomes a part of this Section of the Specification as fully as if repeated herein. B. Items of equipment which are included

More information

ALL-ALUMINUM DOOR & WINDOW FRAMING

ALL-ALUMINUM DOOR & WINDOW FRAMING ALL-ALUMINUM DOOR & WINDOW FRAMING WITH INTEGRATED ALUMINUM DOOR STOP SECTION 08 41 13 ALUMINUM FRAMED ENTRANCES AND STOREFRONTS SPECIFICATION PART 1 GENERAL 1.1 SECTION INCLUDES: A. Prefinished aluminum

More information

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES 2016-03-24 Page 1 SECTION 08360 SECTIONAL OVERHEAD DOORS DESCRIPTION MODEL 900 PRODUCT FEATURES Sectional steel overhead doors, industrial grade heavy duty construction. BASIC USES / RELATED USES Sectional

More information

SECTION HVAC GRAVITY VENTILATORS

SECTION HVAC GRAVITY VENTILATORS SECTION 23 37 23 HVAC GRAVITY VENTILATORS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

FoldingAccess Series Aluminum Folding Door System

FoldingAccess Series Aluminum Folding Door System HORTON AUTOMATICS - ARCHITECTURAL SPECIFICATIONS, 1/2008 FoldingAccess Series 4-4200 Aluminum Folding Door System DIVISION 08 - OPENINGS SECTION 08 42 29.13 FOLDING AUTOMATIC ENTRANCES Specifier Note:

More information

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers) SECTION 10 51 00 Summit Phenolic Lockers (Solid Phenolic Lockers) Part 1-General 1.01 Summary A. Section includes: solid phenolic lockers solid phenolic benches 1.02 Submittals A. Submittals: Comply with

More information

SECTION AIR FILTERS

SECTION AIR FILTERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components Moduline Acoustic Enclosure System Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components Lab certified acoustic ratings Broad range of performance levels 63 Hz

More information

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers. SECTION 230529 - HANGERS AND SUPPORTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Sleeves. 6. Mechanical sleeve seals. 7. Firestopping

More information

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS Ideal for applications requiring space division, visibility and security Used in bank lobbies, offices, conference areas, interior storefronts and arena skyboxes

More information

Cold Rooms Kide

Cold Rooms Kide COLD ROOMS Cold Rooms 2 Cold under control KIDE it is a business Group manufacturer of cold-rooms, insulation panels, insulated doors, refrigeration units and drying units, offering integral solutions

More information

SECTION DIRECTORIES

SECTION DIRECTORIES PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 13 00 DIRECTORIES SPEC WRITER NOTES: 1. Delete // // if not applicable to project. Also delete any other item or paragraph not applicable in the section and

More information

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary The S.10 ALL ALUMINUM LIFT & SLIDE DOOR SYSTEM Expanding spaces to the extraordinary Overview Elevation View of a 4-panel Lift & Slide Door System - Stacked Configuration Panda s Lift & Slide Door Systems

More information

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL Aluminum Flush Doors and Frames SPECIFICATIONS Section 081116 [8120] Cline Aluminum Doors, Inc. 112 32nd Avenue West Bradenton, FL 34205-8907 Toll-Free (800) 648-6736 Office (941) 746-4104 Fax (941) 746-5153

More information

FITOCLIMA WALK-IN STABILITY

FITOCLIMA WALK-IN STABILITY FITOCLIMA WALK-IN TEMPERATURE AND HUMIDITY CHAMBERS ICH, GMP, WHO, FDA COMPLIANT Common applications include: Pharmaceuticals Food and Beverages Cosmetics Veterinary Storage and Conservation Quality control

More information

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over

More information

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY

Specifications PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY PRE ASSEMBLED DOOR SPECIFICATION PART 1 GENERAL 1.01 SUMMARY A. This section pertains to items known commercially as a complete door opening assemblies. B. Complete door opening assemblies includes a door,

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable

More information

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500 07721 ROOF ASSEMBLY SUPPORTS FOR ROOFTOP EQUIPMENT ****************************************** SPECIFIER: All roof-related items above or outside the structural roof deck, including such work as blocking,

More information

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700 SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. Product Data shall be provided for each type of product indicated.

A. Product Data shall be provided for each type of product indicated. 32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical

More information

1-3/4 Whisper Core Door Systems

1-3/4 Whisper Core Door Systems 1-3/4 TESTED AND IN COMPLIANCE WITH ASTM E90, ASTM E413, ASTM E1332, & ASTM E2235. DOOR SYSTEMS ARE IN COMPLIANCE WITH HMMA 865-03 & SDI-128 SPECIFICATIONS. COMPLETE WITH PERIMETER SOUND SEALS, BOTTOM

More information

SECTION ALUMINUM-FRAMED STOREFRONTS

SECTION ALUMINUM-FRAMED STOREFRONTS SECTION 08411 ALUMINUM-FRAMED STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install aluminum storefront entry system, including hardware, glazing, and calking, as

More information