Retrofit with high R-value insulation

Size: px
Start display at page:

Download "Retrofit with high R-value insulation"

Transcription

1 Retrofit with high R-value insulation 64 March

2 Reroofing with high R-value insulation can provide energy savings by Jared O. Blum Photo courtesy of Atlas Roofing Corp., Atlanta. 65

3 At the end of 2009, President Barack Obama urged Congress to provide funding to building owners and homeowners to improve energy efficiency in buildings by replacing doors and roof systems and adding more insulation. He likened the current lack of energy efficiency in most homes and buildings to watching $20 bills float though the window and into the atmosphere. And he went so far as to say the idea may not be very glamorous, but he finds insulation sexy. As the president so eloquently stated, insulation is one of the most important components in a building when it comes to reducing energy costs and decreasing carbon footprint. Much of the existing building stock still has 30 or more years of service life and could be vastly improved during the long term if owners consider reroofing with high R-value roof systems. A high R-value roof system can save a building owner money, increase a building s energy efficiency and reduce greenhouse gas emissions. And in the retrofit roofing market, high R-value roof systems present a 50 billion-square-foot opportunity for roofing contractors. A high R-value roof system provides a level of thermal resistance, or R-value, higher than current minimum levels required by building code standards and practices. The most effective way to achieve this performance level is by using more insulation than is required by code. The exact insulation level needed to achieve superior performance with a high R-value roof system varies according to the criterion applied, but most high-performance building guidelines suggest the level should be up to 30 percent above minimum required values. Executive Order 13423, Strengthening Federal Environmental, Energy, and Economic Management, which sets sustainability goals for federal agencies, provides a good benchmark, setting a building s high-performance target at a minimum 30 percent improvement in energy efficiency by Based on data compiled by the Department of Energy s Office of Energy Efficiency and Renewable Energy, the Center for Environmental Innovation in Roofing estimates there are more than 50 billion square feet of low-slope roof systems in the U.S. For every roof system installed on a new building, about three additional roofs are installed on existing buildings to replace older, less energy-efficient roof systems. As a result, the roofing industry s reach exceeds new commercial construction by a factor of three, accounting for more than 4 billion square feet of total low-slope roof system installations annually. According to the center, if low-slope roof systems insulation levels were upgraded from their current R-values to high R- value roof systems, annual energy savings would exceed $2 billion. Energy savings You may recall that in 2007, the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Inc. increased required insulation levels for low-slope roof systems in ASHRAE , Energy Standard for Buildings Except Low-Rise Residential Buildings. The standard raised the minimum insulation value of commercial roof systems insulated above decks to R-20 for most of the U.S. and Canada with the exception of Climate Zone 1, which is the U.S. southernmost region. Currently, ASHRAE is the most referenced baseline for commercial buildings energy efficiency and also is incorporated into the 2009 International Energy Conservation Code (IECC). IECC and ASHRAE rapidly are being adopted by state and local code jurisdictions throughout the U.S. In fact, all 50 state governors, as part of optional block grants under the federal stimulus bill enacted in 2009, have committed to making state energy code upgrades a priority. Furthermore, ASHRAE is expected to again increase the minimum R-value for building envelopes in ASHRAE The goal is to improve minimum prescriptive targets by 30 percent from the standard s 2004 edition. Projected energy savings resulting from specifying and installing a high R-value roof system can be determined with available software modeling systems. For example, NRCA s EnergyWise Roof Calculator Online can demonstrate how a high R-value roof system can offset or pay for the costs of the upgraded insulation. The EnergyWise Roof Calculator Online, available at energywise.nrca.net, is a Web-based application that provides a graphical method of constructing roof assemblies to evaluate thermal performance and estimates energy costs in normal operating conditions. The application determines annual energy cost values associated with the roof system only (not the walls), which are useful when comparing energy costs and savings with the cost of upgrading and installing various insulation amounts. Roof retrofitting As I mentioned, one of the most significant opportunities to increase buildings energy efficiency lies with the 50 billion square feet of low-slope roof systems currently available for retrofit annually. Energy-efficiency gains can be obtained whether an existing roof system is torn off to the deck or re-covered. 66 March

4 Moisture concerns The decision to replace an existing roof system often is driven by roof leaks and moisture intrusion associated with such leaks, which may degrade an existing roof system and perhaps other parts of a building. Therefore, understanding the condition of an existing roof system is critical for successful high R-value retrofit roof system installation even if the existing roof system is removed in its entirety. There are several important actions you should take to minimize moisture concerns in existing buildings and roof systems. First, inspect critical building and roof interfaces. Common entry points of moisture intrusion into a roof system are at interfaces between the roof system and other building elements such as parapet walls, penthouses, roof edges, penetrations and elevated roof curbs. All interfaces should be inspected by a roofing professional, and any deficiencies should be corrected before reroofing. To ensure latent moisture will not adversely affect the long-term performance of a re-cover roof system, a roof moisture survey should be conducted, especially for any building that has experienced observable water leakage. Moisture surveys can be conducted using various nondestructive technologies, including infrared and nuclear scanning; these technologies can be combined with roof core cuts to validate the results. Thermal breaks Numerous studies have demonstrated the energy savings provided by an insulated roof system may be compromised by thermal breaks in the system, especially at joints and gaps within the insulation layers, at mechanical fasteners, and at intersections with building walls and penetrations. Certain practices can minimize energy losses at these locations when retrofitting with a high R-value roof system. Careful measurement, cutting and fitting of insulation materials is necessary. Most modern insulating materials easily can be cut in the field, and significant thermal value can be retained through proper measuring and fitting of materials around roof penetrations and flashings. Also, spray-applied insulations may be used to eliminate board joints and cutting and fitting. You also should install insulation boards in two or more staggered layers. Polyisocyanurate Insulation Manufacturers Association (PIMA) Technical Bulletin 113, which can be accessed at PIMA s Web site, identifies the benefits of UDLX Economical, mechanically fastened underlayment will not tear or rip in high wind. MT Coated with green non-slip fiber felt and sbs modified Bitumen. This peel and stick product has a split polyester carrier film. Economical Synthetic roofing underlayment Excellent strength and safety properties MT BREA is a breathable, strong underlayment with high safety rating UDLX Peel and stick product designed for metal, tile and general use BREA Mechanically fastened breathable underlayment with superior strength safety properties. UDLX - 5 Layer Construction POLYESTER FIBER-GRIP WITH ANTI-SLIP BONDING MATERIAL POLYPROPYLENE WOVEN FABRIC BONDING MATERIAL PE HIGH-FRICTION FILM See us at International Roofing Expo booth #1319 F 25 LIMITED YEAR WA R R A N T Y NON-SLIP I P I B E R - G R BREA Nemco Industries Inc nemco@telus.net TROUBLE-FREE, SAFE AND LONG-LASTING Circle Reader Service #180 ProfessionalRoofing March

5 multilayered roof insulation boards and their ability to reduce the potential for thermal loss at board joints. Flashing and drainage Because insulation levels recommended for high R-value roof systems require greater total roof system thickness compared with older roof systems, wall and curb flashings may need to be raised to maintain minimum flashing heights. Additionally, a roof system s existing drainage pattern may need to be modified to ensure effective drainage and prevent ponding. And adding drains may be required to accommodate a roof system s modified drainage patterns. To minimize flashing and drainage concerns in existing buildings and roof systems, a topographical survey of the existing roof surface may be conducted to determine existing drainage patterns. A proper understanding of the roof surface s drainage pattern is important because building settling and deflection of the roof structure over time may significantly alter intended roof drainage patterns. A roof s existing elevations and contours may be easily determined using conventional land survey instruments and methods or a visual survey noting locations of ponding or inefficient drainage on the roof surface can be performed. Also, for roof system tear-off (not recover), remove less-efficient roof insulation types. Many roof insulating materials used before the development of high R-value insulations provide a relatively low R-value per inch of thickness. Polyisocyanurate, XPS, EPS and spray polyurethane foam are high R-value insulations. Removing less-efficient insulation materials and replacing them with high R-value insulation effectively can free up additional roof thickness to help preserve necessary flashing heights. Parapets and curbs may need to be reconstructed to maintain minimum flashing heights. If the distance between the tops of roof flashings on walls and curbs and the top of the new roof surface is inadequate to prevent water intrusion (8 inches minimum is recommended), reconstructing parapets and raising curbs may be necessary. A high priority Retrofitting buildings to improve their energy efficiency has been deemed a high priority by U.S. policymakers, economists, building scientists and the design community. You have the opportunity to help lead the movement toward more energyefficient buildings in the right direction with emphasis on high R-value retrofit roof systems. Jared O. Blum is president of the Polyisocyanurate Insulation Manufacturers Association. It s one thing to promise world-class service, and another to deliver it. That s why ABC developed the Customer Service Delivery System (CSDS) a standardized, disciplined series of practices and procedures designed to ensure accuracy and minimize errors. CSDS begins with precise, comprehensive order taking. If you are picking up an order, we ll have you loaded and back to your job site promptly. You can schedule your crews with confidence, because we ll plan deliveries around your needs, double-check every load, call when it s complete, and even document the delivery with digital pictures. We stake our reputation on service. Experience the CSDS difference at ABC Supply. World-Class Service ABC s Promise To You To find the ABC branch nearest you, Call or visit Roofing Siding Windows Tools Gutter Accessories and More Circle Reader Service #2 68 March

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition Spray Polyurethane Foam Design Guidance Insulation and Air Barrier Requirements of the 2012 I-Codes Spray Foam Coalition about the collaboration the center for the polyurathanes industry (CPI) of the

More information

/ TABLE OF CONTENTS /

/ TABLE OF CONTENTS / / TABLE OF CONTENTS / INTRODUCTION ///////////////////////////////////////////////////////////////////////////////////////////////////////////// 1 ROOFS WITH INSULATION ENTIRELY ABOVE DECK I-CODE AND ASHRAE

More information

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION 07530CP EPDM MEMBRANE ROOFING PART 1 GENERAL 1.1 SUMMARY SECTION 07530CP EPDM MEMBRANE ROOFING A. Section includes: 1. Adhered membrane roofing and flashing 2. Mechanically fastened roof insulation 3. Walkway pads 1.2 ARCHITECTURAL

More information

2013 COMMERCIAL PRODUCTS

2013 COMMERCIAL PRODUCTS 2013 COMMERCIAL PRODUCTS EXPLORE GEOMETRY AND SPACE WITHOUT COMPROMISING BUILDING ENVELOPE PERFORMANCE Commercial design considerations come with very specific challenges that can t be addressed with just

More information

UPLIFT RESISTANCE OF EXISTING ROOF DECKS: RECOMMENDATIONS FOR ENHANCED ATTACHMENT DURING REROOFING WORK

UPLIFT RESISTANCE OF EXISTING ROOF DECKS: RECOMMENDATIONS FOR ENHANCED ATTACHMENT DURING REROOFING WORK UPLIFT RESISTANCE OF EXISTING ROOF DECKS: RECOMMENDATIONS FOR ENHANCED ATTACHMENT DURING REROOFING WORK By Thomas L. Smith, AIA, RRC Abstract The uplift resistance of roof decks on many buildings in the

More information

Integrated Air & Water Barrier Systems

Integrated Air & Water Barrier Systems Integrated Air & Water Barrier Systems Presented by [ Jeff Presenter s Key, Georgia-Pacific Name ] Wood Products AIA Course: GP-FF-WRBAB Credit Designation: LU HSW Please add relevant logo here Disclaimer:

More information

MOISTURE MANAGEMENT. Providing roofing and waterproofing solutions. Zionsville High School Roof Asset Management Plan

MOISTURE MANAGEMENT. Providing roofing and waterproofing solutions. Zionsville High School Roof Asset Management Plan MOISTURE MANAGEMENT Providing roofing and waterproofing solutions. Zionsville High School Roof Asset Management Plan Executive Summary Moisture Management conducted a detailed investigation of 34 roof

More information

Weatherproofing & Sealing Systems

Weatherproofing & Sealing Systems Weatherproofing & Sealing Systems Weather Barrier & Waterproofing Residential & Commercial Structures New Construction, Remodeling & Repair Low Slope Roofing Membranes Roofing Underlayments Window & Door

More information

Building Envelope Systems Exam Learning Objectives

Building Envelope Systems Exam Learning Objectives Building Envelope Systems Exam Learning Objectives Roofing Nomenclature 1. Define the following roofing terms: low, flat, sloped, conventional, protected/inverted, hybrid, BUR, modified bitumen, PVC, TPO,

More information

KEEPING UP WITH I-CODES

KEEPING UP WITH I-CODES KEEPING UP WITH I-CODES 54 www.professionalroofing.net MARCH 2015 Changes to the 2015 I-codes affect roof system designs by Mark S. Graham Model codes, such as those developed by the International Code

More information

ROOF REPORT 3130 TCHULAHOMA

ROOF REPORT 3130 TCHULAHOMA ROOF REPORT 3130 TCHULAHOMA MEMPHIS, TENNESSEE BUILDING OWNER: Memphis Shelby County Airport Authority BUILDING MANAGER: MSCAA SURVEY DATE: 6/12/17 BUILDING CONSTRUCTION COMPLETED: 1985 ROOF AREA (SF):

More information

Roof System. and Considerations. Environment friendly e-library

Roof System. and Considerations. Environment friendly e-library Sustainable Roof System Design Drivers and Considerations Environment friendly e-library Sustainable Roof System Design Drivers Sustainable Roof System Design Drivers Buildings use about 50% of all energy

More information

James R. Kirby, AIA Associate Executive Director, Technical Communications National Roofing Contractors Association (NRCA)

James R. Kirby, AIA Associate Executive Director, Technical Communications National Roofing Contractors Association (NRCA) NRCA s 2012 SPF Manual and Technical Updates James R. Kirby, AIA Associate Executive Director, Technical Communications National Roofing Contractors Association (NRCA) SPFA Convention & Expo February 2,

More information

ACFoam-II HCFC Free "Green" Polyiso Specification

ACFoam-II HCFC Free Green Polyiso Specification ACFoam-II HCFC Free "Green" Polyiso Specification To help owners and specifiers, the following specification strategies are offered as they relate to product performance when including HCFC FREE Green

More information

Henry Self-Adhering Roofing Underlayments. self-adhering. roofing underlayments DESIGNED FOR: Shingles. Tile. Metal. Slate

Henry Self-Adhering Roofing Underlayments. self-adhering. roofing underlayments DESIGNED FOR: Shingles. Tile. Metal. Slate Henry Self-Adhering Roofing Underlayments self-adhering roofing underlayments DESIGNED FOR: Shingles Tile Metal Slate why use an underlayment? UNDERLAYMENTS ARE A CRITICAL COMPONENT OF STEEP-SLOPE ROOFING

More information

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts Peter Kalinger Canadian Roofing Contractors Association Dr. B. Baskaran National Research Council of Canada 1 Air Leakage Controlling

More information

Architectural Inspection Low Slope Roofing

Architectural Inspection Low Slope Roofing 0521 Low Slope Roofing All components of the roof system including insulation The roofing on the original building is an Inverted Roof Membrane Assembly (IRMA). It consists of a rubber membrane over ¾

More information

TOPCOAT System Specifications Corrugated Transite Panels

TOPCOAT System Specifications Corrugated Transite Panels TOPCOAT System Specifications Corrugated Transite Panels Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT System Specifications Corrugated Transite

More information

ROOF SUBSTRATE PREP MANUAL

ROOF SUBSTRATE PREP MANUAL ROOF SUBSTRATE PREP MANUAL ALDOCOAT Liquid Applied Roof Restoration Systems AFTER BEFORE JULY 2016 1604 N. Main St. Kannapolis, NC 28081 (800) 474-6019 www.aldoproducts.com ROOF SUBSTRATE PREPARATION Preparation

More information

Roofing Underlayment Systems

Roofing Underlayment Systems Roofing Underlayment Systems New Construction, Additions and Repairs Commercial, Residential or Institutional Applications Self-Adhering and Self-Sealing Overall Weather and Waterproofing Secondary Water

More information

How do you install yours?

How do you install yours? How do you install yours? Darrell Paul Qualistat Building Performance Consultants CSA 440 Just about adding Peel & Stick? 1 Window and door problems Photos / videos Video available for viewing at INSTAGRAM

More information

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET Environmental Protection and Growth Management Department BUILDING CODE SERVICES DIVISION 1 N. University Drive, Box #302 Plantation, Florida 33324 954-765-4400 Broward.org/Building APPLICATION INFORMATION

More information

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com FireShield

More information

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications

More information

FOAMULAR Commercial Roofing

FOAMULAR Commercial Roofing Low Slope Insulated Roof Systems Roofing Systems Single-ply roofing s are flexible sheets of compounded synthetic materials that are manufactured in a factory. Single ply roof systems provide strength,

More information

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof SECTION 07550 MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof This section is based on the products of MFM Building Products Corp., which is located at: 525 Orange St. P. O. Box 340 Coshocton, OH 43812

More information

WATERPROOFING TAMKOWATERPROOFING.COM

WATERPROOFING TAMKOWATERPROOFING.COM WATERPROOFING TAMKOWATERPROOFING.COM DIVISION 7 Powerful Water Control Using the same SBS-modified technology we pioneered in the 1970s, TAMKO continues to raise the standard in waterproofing to help you

More information

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure

Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure Incorporating Insulating Sheathing into the Design of the Thermal and Moisture Management System of the Building Enclosure Peter Baker, Building Science Corporation ABSTRACT With rising utility cost, concerns

More information

Originally Issued: 03/27/2015 Revised: 10/17/2017 Valid Through: 03/31/2018

Originally Issued: 03/27/2015 Revised: 10/17/2017 Valid Through: 03/31/2018 EVALUATION SUBJECT: CERTAINTEED MATTERHORN AND PRESIDIO METAL ING REPORT HOLDER: CertainTeed Corporation 20 Moores Road Malvern, PA 19355 (610) 893-5400 www.certainteed.com CSI Division: 07 THERMAL AND

More information

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017 Truss Heel Heights and Energy Code Requirements Overview Revised 2/17/2017 SBCA has been the voice of the structural building components industry since 1983, providing educational programs and technical

More information

November 10, 2015 Baltimore, MD. presented by

November 10, 2015 Baltimore, MD. presented by Baltimore, MD 2015 I code R values and best practices presented by Mark S. Graham Associate Executive Director, Technical Services National Roofing Contractors Association (NRCA) 1 IBC 2015: Ch. 15: Roofing

More information

SECTION G RELIEF VENTS A-0

SECTION G RELIEF VENTS A-0 SECTION G A-0 TABLE OF CONTENTS Thaler Or Equal RV-1A/-RV-1C Relief Vent RV-2A/-RV-2C Relief Vent RV-3A/-RV-3C One Way Relief Vent Relief Vent Specification G-0 G-1 G-2 G-3 G-4, G-5, G-6 WHAT IT TAKES

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3909 Issued 07/2017 This report is subject to renewal 07/2018. DIVISION: 07 00 00

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 07 40 00 Roofing 1. General Several factors repeatedly show up during the inspection of roofs that have failed prematurely. They include inappropriate use of materials, poor drainage systems, poor details

More information

/BUT BuyLine BUtler roof systems ROOF SYSTEMS DESIGN AND SELECTION GUIDE

/BUT BuyLine BUtler roof systems ROOF SYSTEMS DESIGN AND SELECTION GUIDE 07 61 00/BUT BuyLine 3769 BUtler roof systems ROOF SYSTEMS DESIGN AND SELECTION GUIDE PAGE 1 800.250.5596 OVERVIEW, BUILDING GREEN CONTENTS Overview 2 Product Selection Chart 3 Green Attributes 3 MR-24

More information

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual SECTION 07 22 16 - ROOF AND DECK INSULATION Specifier Note: There are numerous types of roof insulation, some which are installed in multiple-layer roof assemblies. Specifier to verify Project requirements

More information

Chicago Roofing Contractors Association

Chicago Roofing Contractors Association Chicago Roofing Contractors Association CSI Chicago Specifiers Roundtable CRCA Report Illinois 1/1/2013 Adoption ICC s 2012 International Energy Conservation Code Bill McHugh, CRCA Executive Director &

More information

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 075423 - THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Division 00 Bidding Requirements and other Division

More information

Specifications. When specifying metal panel roof systems, roof. system designers and specifiers need to be aware

Specifications. When specifying metal panel roof systems, roof. system designers and specifiers need to be aware 32 www.professionalroofing.net OCTOBER 2012 When specifying metal panel roof systems, roof system designers and specifiers need to be aware of specific standards. Sometimes, the standards applicable to

More information

Lightweight Insulating Concrete Roof Decks

Lightweight Insulating Concrete Roof Decks MeARlCrEte Tm Lightweight Insulating Concrete Roof Decks WWW.AErIXINDUsTrIEs.COm M EARLCRETETM lightweight insulating concrete is produced on the job site by mixing Portland cement -water slurry with the

More information

Section 7 Waterproofing Roofing Standards

Section 7 Waterproofing Roofing Standards Section 7 Waterproofing Roofing Standards Section 7 Waterproofing Roofing Standards... 1 Purpose... 3 Roofing Assemblies... 3 ASTM Standards... 4 Design considerations... 7 Purpose The purpose of this

More information

SECTION PREPARATION FOR RE-ROOFING

SECTION PREPARATION FOR RE-ROOFING SECTION 07 01 50.19 PREPARATION FOR RE-ROOFING SPEC WRITER NOTES: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Edit Summary article below after establishing

More information

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO Maxwell C. Baker: Roofs : Design Application and Maintenance IT S ALL IN THE DETAILS and everything is connected COMPONENTS AND THEIR

More information

Originally Issued: 09/19/2014 Revised: 10/17/2017 Valid Through: 11/15/2017

Originally Issued: 09/19/2014 Revised: 10/17/2017 Valid Through: 11/15/2017 EVALUATION SUBJECT: QUALITY EDGE MATTERHORN METAL ING REPORT HOLDER: Quality Edge, Inc. 2712 Walkent Drive Walker, MI 49544 (888) 784-0878 www.quality-edge.com CSI Division: 07 THERMAL AND MOISTURE PROTECTION

More information

Carpenter Level 2 Rev. September 2017

Carpenter Level 2 Rev. September 2017 Level 2 A5 Site Layout II Duration: 14 hours 7 hours 7 hours Upon completion of this unit the apprentice will demonstrate knowledge of site layout tools and equipment and their applications and procedures

More information

INTRODUCTION Twentieth-century stucco wall claddings

INTRODUCTION Twentieth-century stucco wall claddings It has long been determined that incidental moisture can find its way past the cement stucco membrane on framed walls and with proper design, detailing and installation, the assembly works. However, excessive

More information

PIMA PERFORMANCE BULLETIN Polyiso and Unfaced Mineral Wool Board Insulation in Commercial Roof Applications

PIMA PERFORMANCE BULLETIN Polyiso and Unfaced Mineral Wool Board Insulation in Commercial Roof Applications PIMA PERFORMANCE BULLETIN Polyiso and Unfaced Mineral Wool Board Insulation in Commercial Roof Applications Polyiso roof insulation is one of the most thermally efficient rigid board insulations. It exceeds

More information

Hurricane- Resistance. designations: WHY FORTIFIED? DESIGNATION PROCESS

Hurricane- Resistance. designations: WHY FORTIFIED? DESIGNATION PROCESS Hurricane- Resistance Designation The goal of the FORTIFIED for Existing Homes program is to strengthen your home against specific regional natural hazards through a retrofitting process. Depending on

More information

ROOF ASSEMBLIES CHAPTER 9

ROOF ASSEMBLIES CHAPTER 9 CHAPTER 9 ROOF ASSEMBLIES SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. SECTION R902 ROOF CLASSIFICATION

More information

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES UL Evaluation Report UL ER18920-01 Issued: August 15, 2014 Visit UL s On-Line Certifications Directory: www.ul.com/erdirectory for current status of Report. UL Category Code: ULEX CSI MasterFormat DIVISION:

More information

Lithia Dodge East 5500 L St. Omaha, NE

Lithia Dodge East 5500 L St. Omaha, NE Lithia Dodge East 5500 L St. Omaha, NE Perimeter Photos Failed Joints at North Rear Wall Control Joints Look Good Inadequate Downspout Elbows Erosion Along Wall Minor Efflorescence Roof Section Photos

More information

Margaret Batts Tobin Laboratory

Margaret Batts Tobin Laboratory Roof Evaluation of Margaret Batts Tobin Laboratory The University of Texas At San Antonio Performed for UTSA Zero/Six Consulting, LLC 8423 Stewart Road Galveston, Texas 77554 409 740 0090 voice Table of

More information

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS SECTION 075216 - PART 1 - GENERAL 1.1 SUMMARY A. Section includes styrene-butadiene-styrene (SBS) modified bituminous membrane roofing. 1.2 DEFINITIONS A. Hot Roofing Asphalt: Roofing asphalt heated to

More information

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings FINEGAN INSPECTION SERVICES, INC. 27 Laurelwood Drive Milford Ohio, 45150 513 683-0733 RESIDENCE LOCATION INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings OVERVIEW The report

More information

ROOF ASSEMBLIES CHAPTER 9

ROOF ASSEMBLIES CHAPTER 9 CHAPTER 9 ROOF ASSEMBLIES > SECTION R901 GENERAL R901.1 Scope. The provisions of this chapter shall govern the design, materials, construction and quality of roof assemblies. Pursuant to ORS 215.730; if

More information

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction. INTRODUCTION National model energy codes are advancing the way in which we approach building commercial and residential exterior walls by emphasizing the use of continuous insulation (CI) systems, which

More information

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein. SECTION 10530 - EXTRUDED ALUMINUM WALKWAY COVERS PART I - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General, Supplementary, and Special Conditions and Division

More information

2015 IECC Whole Building Air Leakage Compliance

2015 IECC Whole Building Air Leakage Compliance 2015 IECC Whole Building Air Leakage Compliance Presented by: Jeffrey Crowe, PE Project Manager www.becx.com www.pieglobal.com September 2012 Learning Objectives Understand 2015 International Energy Code

More information

Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists

Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists With information provided by the Insurance Institute for Business & Home Safety Protection from the top

More information

THE BRITE THING TO DO

THE BRITE THING TO DO REDUCING ENERGY CONSUMPTION IMPROVING AIR QUALITY THE BRITE THING TO DO BRITE-n-EZ Enhanced Coating Application Process on Black EPDM Roof Membrane BRITE-n-EZ EPDM Application Instructions CLEANING Remove

More information

Innovating Continuous Exterior Insulation. Theresa A. Weston, PhD. 1

Innovating Continuous Exterior Insulation. Theresa A. Weston, PhD. 1 ABSTRACT Innovating Continuous Exterior Insulation Theresa A. Weston, PhD. 1 As the need to reduce energy usage and carbon consumption has increased, the need for energy efficient building envelopes has

More information

technical bulletin ROOFING CORPORATION

technical bulletin ROOFING CORPORATION ROOFING CORPORATION technical bulletin TO: All Region Managers, Plant Managers, National Account Managers, Sales Representatives, Account Executives, and Atlanta Sales FROM: Ed Todd, Director, Product

More information

United States R E S I D E N T I A L. The Value of Residing With STYROFOAM Brand XPS Insulation

United States R E S I D E N T I A L. The Value of Residing With STYROFOAM Brand XPS Insulation United States R E S I D E N T I A L The Value of Residing With STYROFOAM Brand XPS Insulation 2 resists moisture Residing is a great opportunity to increase a home s value with a fresh, new look. It s

More information

FIRESTONE RUBBERGARD EPDM

FIRESTONE RUBBERGARD EPDM FIRESTONE RUBBERGARD EPDM One Source. Many Choices. That s Firestone. 191587 RubberGard.indd 1 8/14/08 8:42:18 AM Fir e s t o n e Bu i l d i n g Pr o d u c t s Choose what works. Choose Firestone. Contractors,

More information

SECTION ELASTOMERIC MEMBRANE ROOFING

SECTION ELASTOMERIC MEMBRANE ROOFING SECTION 07 5300 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Elastomeric roofing membrane, mechanically fastened conventional application. B. Insulation, flat and tapered. C. Flashings. D. Roofing cant strips,

More information

Siding and Soffit Installation Guidelines

Siding and Soffit Installation Guidelines Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field

More information

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions. SECTION 07710 MANUFACTURED ROOF SPECIALTIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Roof drains for new roofing. B. Roof drains for reroofing. C. Roof drains for retrofitting into existing roof drains.

More information

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC. 0 Most Widely Accepted and Trusted ICC ES Legacy Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ER 520 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00 00 THERMAL

More information

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO SECTION 07220 - ROOF INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work included: The Roofing Contractor will provide all polyisocyanurate insulation and high density wood fiber roof insulation (tapered

More information

J41 Reinforced bitumen membrane roof coverings

J41 Reinforced bitumen membrane roof coverings J41 Reinforced bitumen membrane roof coverings To be read with Preliminaries/General conditions. A comprehensive waterproofing system comprising two reinforced bituminous membranes fully adhered to thermal

More information

Engineered Roof Solutions

Engineered Roof Solutions Engineered Roof Solutions VARCO PRUDEN BUILDINGS From Varco Pruden Retrofit and Reroofing LONG-TERM ROOF SOLUTIONS Slope Build-Up Solution Re-Slope for Water Management Before After Metal Over-Metal-Solution

More information

INTRODUCTION. Inspection Procedures oinitial Inspection Report. Visual Inspection Physical Sampling (Core and Slit Samples)

INTRODUCTION. Inspection Procedures oinitial Inspection Report. Visual Inspection Physical Sampling (Core and Slit Samples) INTRODUCTION Inspection Procedures oinitial Inspection Report Visual Inspection Physical Sampling (Core and Slit Samples) ROOF INSPECTION PROCEDURES Occurs upon project completion Includes visual observation

More information

The American Chemistry Council Clean Energy Economic Recovery Proposals December 2008

The American Chemistry Council Clean Energy Economic Recovery Proposals December 2008 The American Chemistry Council Clean Energy Economic Recovery Proposals December 2008 American Chemistry supports funding clean energy programs as part of an economic recovery package. American Chemistry

More information

SHEET METAL ROOF TEST REPORT

SHEET METAL ROOF TEST REPORT SHEET METAL ROOF TEST REPORT Introduction The time tested performance of the double lock standing seam and batten seam metal roofing is demonstrated by thousands of squares successfully installed by SMACNA

More information

SL175 Panel Technical Data Guide

SL175 Panel Technical Data Guide Description SL175 is a integral snap-lock standing seam roofing panel used on commercial and residential applications. The panel is factory formed in continuous lengths up to 60-0 long. Attachment to either

More information

EVALUATION REPORT Boral Roofing 7575 Irvine Center Drive Suite 100 Irvine, CA

EVALUATION REPORT Boral Roofing 7575 Irvine Center Drive Suite 100 Irvine, CA EVALUATION REPORT Boral Roofing 7575 Irvine Center Drive Suite 100 Irvine, CA. 92618 EXTERIOR RESEARCH & DESIGN, LLC. 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243

More information

FLORIDA BUILDING CODE

FLORIDA BUILDING CODE FLORIDA BUILDING CODE Fifth Edition (2014) Test Protocols for High-Velocity Hurricane Zones Florida Test Protocols for High-Velocity Hurricane Zones, 5th Edition (2014) First Printing: March 2015 ISBN:

More information

TOPCOAT Restoration Specifications Structural Concrete

TOPCOAT Restoration Specifications Structural Concrete TOPCOAT Restoration Specifications Structural Concrete Updated: 1/11 Quality You Can Trust From North America s Largest Roofing Manufacturer! www.gaf.com TOPCOAT Restoration Specifications Structural Concrete

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows. SECTION 085113 - ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fixed and operable aluminum-framed windows. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide aluminum windows capable

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2119 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00

More information

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING (TO RESTORE EPDM MEMBRANES) PART 1 GENERAL 1.01 DESCRIPTION A. The scope of this design guideline is to describe the installation of the ALDOCOAT Silicone reflective

More information

THE SITUATION WITH STEEL DECKS

THE SITUATION WITH STEEL DECKS THE SITUATION WITH STEEL DECKS Steel roof deck design can affect roof system selection and design by Mark S. Graham 32 www.professionalroofing.net MARCH 2017 teel roof decks commonly are encountered in

More information

Self-Adhesive Underlayments for Steep Slope Roof Systems POLYSTICK ROOF UNDERLAYMENTS

Self-Adhesive Underlayments for Steep Slope Roof Systems POLYSTICK ROOF UNDERLAYMENTS Self-Adhesive Underlayments for Steep Slope Roof Systems POLYSTICK ROOF UNDERLAYMENTS PROTECT what matters most High Temperature Metal Roofs Pages... 2-3 Concrete/Clay Roofs Pages... 4-7 Shingle, Shake,

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Differences between EnCon Insulated Precast and EIFS

Differences between EnCon Insulated Precast and EIFS Differences between EnCon Cover Differences between EnCon EnCon produces a number of different insulated precast concrete products. They range from Insulated Wall panels, Styrocore Insulated Wall Panels,

More information

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC. SPECIFICATION GUIDELINE FOR SMOOTH ROOF SUBSTRATES INCLUDING MODIFIED BITUMEN, SMOOTH ASPHALT, EPDM, TPO, AND PLYWOOD. Part 1 General Information For the purpose of clarification in this document, the

More information

Imagine a roof that lasts forever. Restoration Solutions Engineered for the Life of your Schools

Imagine a roof that lasts forever. Restoration Solutions Engineered for the Life of your Schools Imagine a roof that lasts forever Restoration Solutions Engineered for the Life of your Schools ROOFING & BUILDING MAINTENANCE Imagine never buying another new roof. Sound too good to be true? It s true,

More information

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications INTRODUCTION Rmax recommends that any insulation which is laid over a steel or wood roof deck be attached with mechanical

More information

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009 Is Your Envelope Effective? Patrick Roppel P Eng Patrick Roppel P.Eng BCBEC Luncheon January 29, 2009 Goals for this Presentation Why we might be concerned with heat loss through the envelope (U-value

More information

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION Revised September 14 The General Trade Knowledge portion of the examination is administered daily in Computer Based Testing (CBT)

More information

Inspection of New One- and Two- Family Dwellings

Inspection of New One- and Two- Family Dwellings Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Inspection of New One- and Two- Family Dwellings Planning and Development

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

In 2000, a new, prescriptive test method (CAN/ULC-S770, Standard Test

In 2000, a new, prescriptive test method (CAN/ULC-S770, Standard Test In 2000, a new, prescriptive test method (CAN/ULC-S770, Standard Test Method for Determination of Long-term Thermal Resistance of Closed-Cell Thermal Insulating Foams ) for determining R-values of certain

More information

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION BUILDING & SAFETY DIVISION 6360 FOUNTAIN SQUARE DRIVE, CITRUS HEIGHTS, CA 95621 Phone: (916) 727-4760 Purpose: To establish a procedure for complying with the provisions of Chapter 15 of the California

More information

Chapter 2 Understanding The Problem

Chapter 2 Understanding The Problem Chapter 2 Understanding The Problem What Causes Most Of The Problems With Stucco? EIFS was originally intended to seal and insulate the exterior of the home from the elements. Problems occur when poorly

More information

Roofing Insulation Products The Trusted Leader in Polyiso Roofing Insulation Solutions

Roofing Insulation Products The Trusted Leader in Polyiso Roofing Insulation Solutions Roofing Insulation Products The Trusted Leader in Polyiso Roofing Insulation Solutions Improving Your Design. Leading the Industry in Product Excellence Since 1978, Rmax has evolved to become the respected

More information

Prestige Series. (Horizontal Install.) Installation Guide

Prestige Series. (Horizontal Install.) Installation Guide Prestige Series (Horizontal Install.) Installation Guide Prestige Series (Horizontal Install.) Installation Guide - Table of Contents - Section Page General Notes..............................................................

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: POLYVINYL CHLORIDE ROOFING REPORT HOLDER: IB ROOF SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: POLYVINYL CHLORIDE ROOFING REPORT HOLDER: IB ROOF SYSTEMS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 28 Reissued 02/2018 This report is subject to renewal 02/2019. DIVISION: 07 00 00

More information

The Original. The Innovator.

The Original. The Innovator. 50368 York MoistureControl Rev5:50368 YorkMoistureControl 9/11/08 2:33 PM Page 1 The Original. The Innovator. 50368 York MoistureControl Rev5:50368 YorkMoistureControl 9/11/08 2:33 PM Page 2 Through-Wall

More information

Air Infiltration & the Knauf Insulation EcoSeal

Air Infiltration & the Knauf Insulation EcoSeal White Paper BI-WP-04 10-12 Air Infiltration & the Knauf Insulation EcoSeal System EcoSeal & Knauf Insulation Glasswool Products AN WHITE PAPER THE IMPACT OF OTHER BUILDING ELEMENTS ON AIR INFILTRATION

More information