Grinnell Mechanical Products Figure 730 Mechanical Tees - Threaded / Grooved General Description. Technical Data. Page 1 of 8 MAY, 2009 G210

Size: px
Start display at page:

Download "Grinnell Mechanical Products Figure 730 Mechanical Tees - Threaded / Grooved General Description. Technical Data. Page 1 of 8 MAY, 2009 G210"

Transcription

1 Technical Services: Tel: (866) / Fax: (401) Grinnell Mechanical Products Mechanical s - Threaded / Grooved General escription The Mechanical s may be used for any tee connection where a threaded or grooved outlet is needed. They may be converted into a cross when necessary. notice The Mechanical described herein must be installed and maintained in compliance with this document, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their system and devices in proper operating condition. The installing contractor or manufacturer should be contacted with any questions. Technical ata Outlet Threaded or Grooved Working Pressure 500 psi (34.5 ar) Note: Maximum pressure applies to the Mechanical. When connected to a grooved coupling, the rating will be the lesser of the Mechanical or oupling rating. Maximum pressure is a total from all loads, based on standard weight steel pipe. For pipe with other wall thickness or materials contact Tyco Fire & uilding Products. pprovals UL, FM, UL, VdS, and LP Housing uctile iron conforming to STM -536, Grade Protective oatings Non-lead orange paint RL red (optional) non-lead paint Hot dipped galvanized conforming to STM -153 olt/nuts Track Head olts - conforming to STM -183, Zinc Plated, ( Tensile = 110,000 psi/758,422 kpa) Metric - conforming to STM F568M Gasket (specify when ordering) Grade E EPM, green color code -30 F (-34 ) to +230 F (+110 ) Grade T Nitrile, orange color code -20 F (-29 ) to +180 F (+82 ) (See ata Sheet G610 for aid in selecting proper gasket.) FM For Fire Protection pressure rating, listing and approval information, contact Tyco Fire & uilding Products. Page 1 of 8 MY, 2009 G210

2 Page 2 of 8 G210 E ranch Outlet with Female NPT/ISO 7-1 Threaded ranch ( onfiguration) ranch Outlets with Female NPT/ISO 7-1 Threaded ranch (ross onfiguration) threaded Outlets ranch Outlet with one Female NPT/ISO 7-1 Threaded ranch and one Grooved ranch* (ross onfiguration) Run x ranch NSI N Hole ia. ranch End Load Nominal imensions- E olt** / pprox. ross pprox. 2 x 1/2 N50 x N15 2 x 3/4 N50 x N20 2 x 1 N50 x N25 2 x 1-1/4 N50 x N32 2 x 1-1/2 N50 x N40 2-1/2 x 1/2 N65 x N15 2-/4 N65 x N20 2-1/2 x 1 N65 x N25 2-1/2 x 1-1/4 N65 x N32 2-1/2 x 1-1/2 N65 x N40 2-1/2 x 2 N65 x N mm x 1/2 N65 x N mm x 3/4 N65 x N mm x 1 N65 x N mm x 1-1/4 N65 x N mm x 1-1/2 N65 x N mm x 2 N65 x N50 3 x 1/2 N80 x N (66,5) 2.62 (66,5) 2.62 (66,5) (73,2) (73,2) (73,2) 3.00 (76,2) (74,5) 2.94 (74,5) 2.94 (74,5) 3 (79,5) 3.25 (82,6) (91,2) 2.12 (53,8) 2.12 (53,8) 2.12 (53,8) 1.93 (49,0) 1.93 (49,0) 2.38 (60,5) 2.38 (60,5) 2.38 (60,5) 2.19 (55,6) 2.17 (55,1) 2.44 (62,0) 2.44 (62,0) 2.44 (62,0) 2.44 (62,0) 2.25 (57,2) 2.25 (57,2) 6 (65,0) 2.2 (1,0) 2.2 (1,0) 2.2 (1,0) (1,1) (1,1) 3.5 (1,6) 4.1 (1,7) (1,7) (1,8) (2,0) (1,8) 5.1 (2,3) (2,0) Proper hole preparation is required for effective sealing and performance. heck the pipe seal surface within 5 /8 (15.9mm) of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating of the locating collar or flow from the outlet. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendent sprinklers, etc. may not be compatible with the female threaded outlet on the Mechanical. lways confirm compatibility by contacting Tyco Fire & uilding Products. Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. ontact Tyco Fire & uilding Products for details. * See pages 5 & 6 for grooved dimensions. Note: Outlet Threads conforming to ISO 7-1 are available, contact Tyco Fire & uilding Products. Figure 1 (1 of 3) Mechanical Outlet and ross (Threaded)

3 G210 Page 3 of 8 E ranch Outlet with Female NPT/ISO 7-1 Threaded ranch ( onfiguration) ranch Outlets with Female NPT/ISO 7-1 Threaded ranch (ross onfiguration) threaded Outlets ranch Outlet with one Female NPT/ISO 7-1 Threaded ranch and one Grooved ranch* (ross onfiguration) Run x ranch NSI N Hole ia. ranch End Load Nominal imensions- E olt** / pprox. ross pprox. 3 x 3/4 N80 x N (65,0) (1,7) 4.5 (2,0) 3 x 1 N80 x N (65,0) (1,7) 4.5 (2,0) 3 x 1¼ N80 x N32 4 (84,8) (1,8) 4.9 (2,2) 3 x 1½ N80 x N40 8 (85,9) 2.48 (63,0) x 2 N80 x N (103,9) 4.7 (2,1) 6.5 (2,9) 4 x 1/2 N100 x N (93,7) 4 x 3/4 N100 x N (93,7) 4 x 1 N100 x N (93,7) 4 x 1¼ N100 x N32 2 (99,6) 3.00 (76,2) 4 x 1½ N100 x N (75,7) 4 x 2 N100 x N (82,6) (3,7) 4 x 2½ N100 x N65 2 (79,2) (3,7) 4 x 76.1mm N100 x N65 2 (79,2) (3,7) 4 x 3 N100 x N (104,9) 1 (84,1) (6,1) 5 x 1½ N125 x N40 (117,6) 5/8 x 43/4 6.5 (2,9) 7.7 (3,5) 5 x 2 N125 x N50 (117,6) 3.88 (98,6) 5/8 x 43/4 (3,7) 5 x 2½ N125 x N (120,7) 3.88 (98,6) 5/8 x 43/4 7.3 (3,3) 8.7 (3,9) 5 x 76.1mm N125 x N (120,7) 3.88 (98,6) 7.3 (3,3) 8.7 (3,9) Proper hole preparation is required for effective sealing and performance. heck the pipe seal surface within 5 /8 (15.9mm) of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating of the locating collar or flow from the outlet. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendent sprinklers, etc. may not be compatible with the female threaded outlet on the Mechanical. lways confirm compatibility by contacting Tyco Fire & uilding Products. Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. ontact Tyco Fire & uilding Products for details. * See pages 5 & 6 for grooved dimensions. Note: Outlet Threads conforming to ISO 7-1 are available, contact Tyco Fire & uilding Products. Figure 1 (2 of 3) Mechanical Outlet and ross (Threaded)

4 Page 4 of 8 G210 E ranch Outlet with Female NPT/ISO 7-1 Threaded ranch ( onfiguration) ranch Outlets with Female NPT/ISO 7-1 Threaded ranch (ross onfiguration) threaded Outlets ranch Outlet with one Female NPT/ISO 7-1 Threaded ranch and one Grooved ranch* (ross onfiguration) Run x ranch NSI N Hole ia. End Load (ranch) Nominal imensions- E olt** / pprox. ross pprox. 5 x 3 N125 x N mm x 1-1/4 N150 x N mm x 1-1/2 N150 x N mm x 2 N150 x N mm x 2-1/2 N150 x N mm x 76.1mm N150 x N mm x 3 N150 x N mm x 4 N150 x N100 6 x 1-1/4 N150 x N32 6 x 1-1/2 N150 x N40 6 x 2 N150 x N50 6 x 2-1/2 N150 x N65 6 x 3 N150 x N80 6 x 4 N150 x N100 8 x 2-1/2 N200 x N65 8 x 76.1mm N200 x N65 8 x 3 N200 x N80 8 x 4 N200 x N (127,0) 0 (139,7) 5.38 (136,7) 0 (139,7) 5.38 (136,7) 6.25 (158,8) 6.25 (158,8) 6.50 (165,1) 6.38 (162,1) (108,0) 4.04 (102,6) 4.31 (109,5) 4.18 (106,2) 4.18 (106,2) 4.37 (111,0) 4.56 (115,8) 4.25 (108,0) 4.04 (102,6) 4.31 (109,5) 4.18 (106,2) 4.37 (111,0) 4.56 (115,8) 5.12 (130,0) 5.12 (130,0) 5.37 (136,4) 6 (141,2) 5/8 x 43/4 3/4 x 4¾ 3/4 x 4¾ 3/4 x 4¾ 6.9 (3,1) 9.5 (4,3) 10.0 (4,5) 6.9 (3,1) 9.5 (4,3) 10.0 (4,5) 10.2 (4,6) 10.2 (4,6) 1 (5,7) 1 (5,7) 14.7 (6,7) 7.9 (3,6) 14.1 (6,4) 20.1 (9,1) 7.9 (3,6) 14.1 (6,4) 20.1 (9,1) 12.1 (5,5) 12.1 (5,5) 15.1 (6,8) 21.1 (9,6) Proper hole preparation is required for effective sealing and performance. heck the pipe seal surface within 5 /8 (15.9mm) of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating of the locating collar or flow from the outlet. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendent sprinklers, etc. may not be compatible with the female threaded outlet on the Mechanical. lways confirm compatibility by contacting Tyco Fire & uilding Products. Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. ontact Tyco Fire & uilding Products for details. * See pages 5 & 6 for grooved dimensions. Note: Outlet Threads conforming to ISO 7-1 are available, contact Tyco Fire & uilding Products. Figure 1 (3 of 3) Mechanical Outlet and ross (Threaded)

5 G210 Page 5 of 8 ranch Outlet with Grooved ranch ( onfiguration) Run x ranch NSI N 2 x 1-1/4 N50 x N32 2 x 1-1/2 N50 x N40 2-1/2 x 1-1/4 N65 x N32 2-1/2 x 1-1/2 N65 x N40 2-1/2 x 2 N65 x N mm x 1-1/4 N65 x N mm x 1-1/2 N65 x N mm x 2 N65 x N50 3 x 1-1/4 N80 x N32 3 x 1-1/2 N80 x N40 3 x 2 N80 x N50 4 x 1-1/4 N100 x N32 4 x 1-1/2 N100 x N40 4 x 2 N100 x N50 4 x 2-1/2 N100 x N65 4 x 76.1mm N100 x N65 4 x 3 N100 x N80 5 x 1-1/2 N125 x N40 5 x 2 N125 x N50 5 x 2-1/2 N125 x N65 Hole ia. 63,5 End Load (ranch) ranch Outlets with Grooved ranch (ross onfiguration) Grooved Outlets Nominal imensions (66,5) 3.00 (76,2) 9 3 (79,5) 3.25 (82,6) 4 (84,8) 8 (85,9) 2 (99,6) 4.13 (104,9) (117,6) (117,6) 4.75 (120,7) 3.59 (91,2) 4.09 (103,9) ranch Outlet with one Female NPT/ISO 7-1 Threaded ranch* and one Grooved ranch (ross onfiguration) olt** 1/2 x 3 1/2 x 3 1/2 x 3 1/2 x 3 pprox. (1,1) (1,1) 3.5 (1,6) 4.1 (1,8) (2,1) (2,9) 7.3 (3,3) ross pprox. Lbs./(kg) Proper hole preparation is required for effective sealing and performance. heck the pipe seal surface within 5/8 (15.9mm) of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating of the locating collar or flow from the outlet. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. ontact Tyco Fire & uilding Products for details. * See pages 2, 3 & 4 for threaded dimensions. figure 2 (1 of 2) Mechanical Outlet and ross (Grooved)

6 Page 6 of 8 G210 ranch Outlet with Grooved ranch ( onfiguration) Run x ranch NSI N 5 x 76.1mm N125 x N65 5 x 3 N125 x N mm x 1-1/4 N150 x N mm x 1-1/2 N150 x N mm x 2 N150 x N mm x 2-1/2 N150 x N mm x 76.1mm N150 x N mm x 3 N150 x N mm x 4 N150 x N100 6 x 1-1/4 N150 x N32 6 x 1-1/2 N150 x N40 6 x 2 N150 x N50 6 x 2-1/2 N150 x N65 6 x 3 N150 x N80 6 x 4 N150 x N100 8 x 2-1/2 N200 x N65 8 x 76.1mm N200 x N65 8 x 3 N200 x N80 8 x 4 N200 x N100 Hole ia. End Load (ranch) ranch Outlets with Grooved ranch (ross onfiguration) Grooved Outlets Nominal imensions (120,7) 5.00 (127,0) 0 (139,7) 5.38 (136,7) 0 (139,7) 5.38 (136,7) 6.25 (158,8) 6.25 (158,8) 6.50 (165,1) 6.38 (162,1) (90.4) ranch Outlet with one Female NPT/ISO 7-1 Threaded ranch* and one Grooved ranch (ross onfiguration) olt** 3/4 x 4-3/4 3/4 x 4-3/4 3/4 x 4-3/4 pprox. 7.3 (3,3) (3,1) 9.5 (4,3) 10.0 (4,5) 6.9 (3,1) 9.5 (4,3) 10.0 (4,5) 10.2 (4,6) 10.2 (4,6) 1 (5,7) 1 (5,7) ross pprox (3,6) 14.1 (6,4) 20.1 (9,1) 7.9 (3,6) 14.1 (6,4) 20.1 (9,1) 12.1 (5,5) 12.1 (5,5) 15.1 (6,8) 21.1 (9,6) Proper hole preparation is required for effective sealing and performance. heck the pipe seal surface within 5/8 (15.9 mm) of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating of the locating collar or flow from the outlet. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. ontact Tyco Fire & uilding Products for details. * See pages 2, 3 & 4 for threaded dimensions. figure 2 (2 of 2) Mechanical Outlet and ross (Grooved)

7 G210 Page 7 of 8 Limited Warranty Products manufactured by Tyco Fire & uilding Products (TFP) are warranted solely to the original uyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFP. No warranty is given for products or components manufactured by companies not affiliated by ownership with TFP or for products and components which have been subject to misuse, improper installation or maintenance, corrosion, or other external sources of damage. Materials found by TFP to be defective shall be either repaired or replaced, at TFP s sole option. TFP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFP shall not be responsible for system design errors or inaccurate or incomplete information supplied by uyer or uyer s representatives. In no event shall TFP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFP was informed about the possibility of such damages, and in no event shall TFP s liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, size, (NSI inch size or pipe O..), figure number, type of gasket: Grade E EPM Grade T Nitrile Grinnell Mechanical Products, valves, accessories and other products are available throughout the U.S., anada, and internationally, through a network of distribution centers. You may write directly or call for the distributor nearest you. General Notes: It is the esigner s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data are not exceeded. lways read and understand the installation instructions (IH-1000M). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. ertified ompany

8 Page 8 of 8 G TYO FIRE SUPPRESSION & UILING PROUTS, 451 North annon venue, Lansdale, Pennsylvania 19446

G-FIRE GROOVED COUPLINGS

G-FIRE GROOVED COUPLINGS G-FIRE GROOVED COUPLINGS Figure 5 G-FIRE Rigid Page 5 Figure 5 Flexible Page GRINNELL are designed for grooved end pipe and are available in nominal sizes of 25mm (") to 3mm (2") including BS, and ISO

More information

List Prices to Authorized Distributors

List Prices to Authorized Distributors Price Sheet 09 Effective January 0, 209 Supersedes Sheet 48 A Member of The Phoenix Forge Group Conduit Pipe Products Company 0 West Main Street West Jefferson, OH 42 Phone: 4-879-94 Toll Free: 800-848-

More information

List Prices to Authorized Distributors

List Prices to Authorized Distributors Price Sheet 217 Effective February 01, 2017 Supersedes Sheet 716 A Member of The Phoenix Forge Group Conduit Pipe Products Company 101 West Main Street West Jefferson, OH 4162 Phone: 614-879-9114 Toll

More information

List Prices to Authorized Distributors

List Prices to Authorized Distributors Price Sheet 418 Effective April 26, 2018 Supersedes Sheet 18 A Member of The Phoenix Forge Group Conduit Pipe Products Company 101 West Main Street West Jefferson, OH 4162 Phone: 614-879-9114 Toll Free:

More information

Lightweight Flexible Stainless Steel Coupling Style

Lightweight Flexible Stainless Steel Coupling Style Lightweight Flexible Stainless Steel oupling Style 475 17.14 1 4"/25 165.1 1.0 PRODUT DESRIPTION Available s 1 4"/25 165.1 Pipe Material Stainless Steel Type 316 (F8M) Maximum Working Pressure Working

More information

STEEL PIPE COUPLINGS

STEEL PIPE COUPLINGS Price Sheet J-917- Effective September 04, 2017 Supersedes J-317- A Member of The Phoenix Forge Group Phoenix/apitol Phone: 337-783-8628 Fax: 337-783-5360 Toll Free: 888-744-7326 Toll Free: 800-848-1100

More information

STEEL PIPE COUPLINGS

STEEL PIPE COUPLINGS Price Sheet J-718- Effective July 19, 2018 Supersedes J-418- A Member of The Phoenix Forge Group Phoenix/apitol Phone: 337-783-8628 Fax: 337-783-5360 Toll Free: 888-744-7326 Toll Free: 800-848-1100 www.capitolcamco.com

More information

STEEL PIPE COUPLINGS

STEEL PIPE COUPLINGS Price Sheet J-418- Effective April 06, 2018 Supersedes J-917- A Member of The Phoenix Forge Group Phoenix/apitol Phone: 337-783-8628 Fax: 337-783-5360 Toll Free: 888-744-7326 Toll Free: 800-848-1100 www.capitolcamco.com

More information

SEAMLESS STEEL PIPE NIPPLES

SEAMLESS STEEL PIPE NIPPLES Price Sheet SMLS-38 Effective March 6, 08 Supersedes SMLS- A Member of The Phoenix Forge Group Phoenix/Capitol Phone: 337-783-868 Fax: 337-783-5360 Toll Free: 888-744-736 Toll Free: 800-848-00 www.capitolcamco.com

More information

U-BOLT MECHANICAL TEE (SADDLE-LET) Model 300U

U-BOLT MECHANICAL TEE (SADDLE-LET) Model 300U U-BOLT MECHANICAL TEE (SADDLE-LET) U Pipe Material Carbon steel, Schedule 10, Schedule 40. For use with alternative materials and wall thicknesses please contact ARGCO. Maximum Working Pressure Up to 365

More information

CLASS 150 AND XH STAINLESS STEEL PIPE FITTINGS

CLASS 150 AND XH STAINLESS STEEL PIPE FITTINGS Price Sheet SS-407 Effective April 02, 2007 Supersedes SS-806 A Member of The Phoenix Forge Group Phoenix/Capitol Phone: 337-783-8628 Fax: 337-783-5360 Toll Free: 888-744-7326 Toll Free: 800-848-1100 www.capitolcamco.com

More information

CLASS 150 AND XH STAINLESS STEEL PIPE FITTINGS

CLASS 150 AND XH STAINLESS STEEL PIPE FITTINGS Price Sheet Effective October 15, 018 Supersedes SS-714 A Member of The Phoenix Forge Group Phoenix/Capitol Phone: 337-783-868 Fax: 337-783-5360 Toll Free: 888-744-736 Toll Free: 800-848-1100 www.capitolcamco.com

More information

Daniel Orifice Fittings and Meter Tubes

Daniel Orifice Fittings and Meter Tubes Installation and Operating Instructions P/N 3-9008-002, Rev E November 2017 Daniel Orifice Fittings and Meter Tubes Specific to the Pressure Equipment Directive Flow Lifecycle Services for Daniel products

More information

GE Enduris* 3500 silicone roof coating Roof Restoration Warranty - 10 Year

GE Enduris* 3500 silicone roof coating Roof Restoration Warranty - 10 Year GE Enduris* 3500 silicone roof coating Roof Restoration Warranty - 10 Year Building Owner: Address: City: State: Zip: Email: Phone: Project Name: Project Address: City: State: Zip: Roof Size: Warranty

More information

BULWARK BOLLARDS M30 & M50

BULWARK BOLLARDS M30 & M50 BOLLARDS M30 & M50 SINGLE & ARRAY CONFIGURATIONS FIXED & REMOVABLE SHALLOW MOUNT INSTALLATION M30 SINGLE BOLLARD FIXED W/ CAP OPTION SHOWN ABOVE NOTE: Installation drawing shown above, rebar is not included

More information

STEEL PIPE NIPPLE DISCOUNT SHEET

STEEL PIPE NIPPLE DISCOUNT SHEET Price Sheet Effective February 28, 2011 Supersedes CWN-510 A Member of The Phoenix Forge Group CapProducts LTD. Phone: 519-482-5000 Fax: 519-482-7728 Toll Free: 800-265-5586 www.capproducts.com www.capitolcamco.com

More information

Model Number: 1300 Series

Model Number: 1300 Series Model Number: 1300 Series Product Description 17" x 14" Stainless Steel Lavatory Simply Stainless Collection 17" x 14" (43.18cm x 35.56cm) with Overflow High-Quality Durable Stainless Steel For Drop-in

More information

INSTALLATION MANUAL. Guardian Series. QSUS 18 x 40. Manual

INSTALLATION MANUAL. Guardian Series. QSUS 18 x 40. Manual Manual # Guardian Series INSTALLATION MANUAL QSUS 18 x 40 LE MANUEL D'INSTALLATION INSTALLATION HANDBUCH HANDBOEK VAN DE INSTALLATIE MANUAL DE LA INSTALACIÓN 03/07 Copyright 2005. All Rights Reserved.

More information

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

Model T2642E Wall Mount. Television Wall Mount with Tilt Option Model T2642E Wall Mount Television Wall Mount with Tilt Option Getting Started Introduction Congratulations on the purchase of your new Audio Solutions T2642E Television Wall Mount. For maximum benefit,

More information

MODEL NUMBER: 1419 SERIES

MODEL NUMBER: 1419 SERIES 1 PRODUCT DESCRIPTION Semi-Recessed Rectangular Vitreous China Lavatory with Overflow Semi Recessed 2" Above Counter 8" Spread Faucet Drilling Vitreous China High Gloss Ceramic Finish PRODUCT MEASUREMENTS

More information

Product Overview. Solar Ready Electric Storage Tanks. Sustainable Hot Water Solutions Delivered by Apricus

Product Overview. Solar Ready Electric Storage Tanks. Sustainable Hot Water Solutions Delivered by Apricus Product Overview Ready Electric Storage Tanks Sustainable Hot Water Solutions Delivered by Apricus Product Overview Apricus are specifically designed to work with thermal solar collectors in direct flow

More information

STEEL PIPE NIPPLE DISCOUNT SHEET

STEEL PIPE NIPPLE DISCOUNT SHEET Price Sheet J-317-N Effective March 20, 2017 Supersedes J-316-N A Member of The Phoenix Forge Group Phoenix/Capitol Phone: 337-783-8628 Fax: 337-783-5360 Toll Free: 888-744-7326 Toll Free: 800-848-1100

More information

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015 STEEL NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015 FOR THE MOST CURRENT PRODUCT / PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE

More information

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet

3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet 3M Fire Barrier Moldable Putty Pads MPP+ Product Data Sheet 1. Product Description 4 in. x 8 in. (101.6 mm x 203.3 mm), 7 in. x 7 in. (177.8 mm x 177.8 mm) and 9.5 in. x 9.5 in. (241.2 mm x 241.3 mm) pad

More information

Installation and Care Guide

Installation and Care Guide Installation and Care Guide Front Apron Bathtubs This Guide is for the following Front Apron bathtubs: AK-603014 : BRAVO AK-603414 : BRAVO AK-603216 : BRAVO AK-663416 : BRAVO Thank you for allowing SONG

More information

Gasket Maker Anaerobic Adhesives GM10 GM18 GM74 Technical Data November GM10 GM18 GM74 Color Red Red Red Chemistry

Gasket Maker Anaerobic Adhesives GM10 GM18 GM74 Technical Data November GM10 GM18 GM74 Color Red Red Red Chemistry 3 Scotch-Weld TM Technical Data November 2016 Product Description 3M TM Scotch-Weld TM are one-component anaerobic sealants formulated to replace pre-cut gaskets or used as form-in-place gaskets that cure

More information

Installation Instructions

Installation Instructions Installation Instructions Thank you for choosing the Synergy Reef Shadow Overflow. Please note that this is a Do-It-Yourself project and can be installed in either glass or acrylic aquariums. Always keep

More information

Daniel TM Ultrasonic Flow Meters

Daniel TM Ultrasonic Flow Meters Installation and Operating Instructions Manual Part Number 3-9000-745 Revision F August 2017 Daniel TM Ultrasonic Flow Meters Installation and Operating Instructions Specific to the Pressure Equipment

More information

Process Returns in VOTW

Process Returns in VOTW Process Returns in VOTW 1. From the Menu bar, select Other Functions Returns. 2. From the Returns Action list, select one of the following: Add a Claim Request: Request a new return on an Eaton product.

More information

OptoLum MegaLine RGBW Luminaire

OptoLum MegaLine RGBW Luminaire OptoLum MegaLine RGBW Luminaire Getting Started OptoLum MegaLine RGBW Luminaires offer indoor cove lighting and wall washing in a compact linear form. This guide contains important information on planning,

More information

TERMS AND CONDITIONS OF SALE

TERMS AND CONDITIONS OF SALE TERMS AND CONDITIONS OF SALE GENERAL Conditions of Sale: These Terms and Conditions of sales ( Agreement ) shall apply to all sales of products by LF Illumination, LLC. As used in these Terms and Conditions

More information

OWENS CORNING Limited Lifetime Warranty for EnergyComplete System. OWENS CORNING Limited Lifetime Warranty for EnergyComplete Sealant

OWENS CORNING Limited Lifetime Warranty for EnergyComplete System. OWENS CORNING Limited Lifetime Warranty for EnergyComplete Sealant Limited Lifetime Warranty for EnergyComplete System Thank you for your recent purchase of an EnergyComplete System manufactured by Owens Corning Insulating Systems, LLC ( Owens Corning ). The EnergyComplete

More information

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017 Installation Guide Document No. 1788-01 Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL:

More information

General Safety Information

General Safety Information TM General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX: ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS COMBINATION STATIONS MODELS S1330-FPB/S1340-FPB/S2330-FPB/S2340-FPB/2330-FPB-ASP

More information

Installation and Care Guide

Installation and Care Guide Installation and Care Guide Freestanding Bathtubs This Guide is for the following Freestanding bathtubs: FP SERENADE FG HARMONY FD ARIA FM DUET Thank you for allowing SONG the honor of earning your business.

More information

C.I.Agent Barrier Boom Containment System

C.I.Agent Barrier Boom Containment System Manufacturer's Recommended Installation Processes for C.I.Agent Barrier Boom Containment System Manufactured by: C.I.Agent Solutions, LLC 11760 Commonwealth Drive Louisville, KY 40299 866-242-4368 502-267-0101

More information

ARALDITE AV 119 EPOXY ADHESIVE PASTE

ARALDITE AV 119 EPOXY ADHESIVE PASTE ARALDITE AV 119 EPOXY ADHESIVE PASTE DESCRIPTION: Araldite AV 119 epoxy adhesive is a one-component, multi-purpose paste that is thixotropic and is designed for heat curing at temperatures from 248 F to

More information

TrueClean ToteTilter TM

TrueClean ToteTilter TM TrueClean ToteTilter TM Installation, Operation, and Maintenance Manual ww w.trueclean.us 1 TrueClean ToteTilter Table of Contents Safety... 3 Important Safety Information... 3 Introduction... 4 About

More information

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE) SECTION 02623 HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE) PART 1 - GENERAL 1.1 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals required and install high density

More information

ipd Intercooler S60 5cyl turbo V70/XC70 5cyl turbo ipd #114813

ipd Intercooler S60 5cyl turbo V70/XC70 5cyl turbo ipd #114813 PI-406 12/11 Dedicated to improving vehicle fun, safety & performance Installation Instructions *PI406* ipd Intercooler S60 5cyl turbo 2003-2009 V70/XC70 5cyl turbo 2003-2007 ipd #114813 SUGGESTED TOOLS

More information

PileForm F. Pile Jacket Installation Guide FiveStarProducts.com TECHNICAL SUPPORT

PileForm F. Pile Jacket Installation Guide FiveStarProducts.com TECHNICAL SUPPORT TECHNICAL SUPPORT 1-800-243-2206 FiveStarProducts.com Pile Jacket Installation Guide -2- STEP 1 1. Clean existing pilings using a minimum of 4,000 psi high-pressure water blast or other mechanical means

More information

Installation and Use Instructions for the Big Ass Workbench Manufactured by Mercer Innovation, LLC

Installation and Use Instructions for the Big Ass Workbench Manufactured by Mercer Innovation, LLC Introduction Mercer Innovation, LLC has proudly and domestically manufactured the first in a line of industrial benches and furniture for serious shop use, as described below. Description The Big ASS workbench,

More information

Biogas Plant Construction Guide

Biogas Plant Construction Guide D I S C L A I M E R O F L I A B I L I T Y A N D W A R R A N T Y This publication describes the author s opinions regarding the subject matter herein. The author and publisher are not rendering advice or

More information

S8VM Series Replacement Brackets

S8VM Series Replacement Brackets Original model Bottom mounting Front mounting Side mounting Original model: S8VM Replacement model: S8FS-G Replacement bracket Model scheduled to be discontinued Recommended replacement model Model Page

More information

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

3601 E. 34th St. Tucson, AZ USA Tel Fax Web: Equipment Type: Model: Electrical Requirements: Frequency: Manual Revision Date: Air Flow Sound Level Fume Hood FUME HOOD 110V 60 Hz February 15, 2018 1175-1470 cfm 65 dba Contents Warranty PAGE ii 1.0

More information

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2 V 2.0 ASSEMBLY GUIDE Series 2 TABLE OF CONTENTS OVERVIEW General Specifications...1 Cautions and Disclaimers...1 Contents of Kit...1 Tools Required For Assembly...2 Time Required to Assemble...2 ASSEMBLING

More information

LG-WMF86BH FOR LG-86BH5C

LG-WMF86BH FOR LG-86BH5C LG-WMF86BH FOR LG-86BH5C ENG 1 2016-06-2 #:126-9128-2 (2016-10-19) WRNING ENG - This product is designed to be installed on wood stud, solid concrete or cinder block walls. Hardware is included for wood

More information

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

END TRUCKS WHEEL SIZES: 9, 12, 15 & 18 OPERATION, SERVICE & PARTS MANUAL STRUCTURAL TUBE ROTATING AXLE WHEEL SIZES: 9", ", 5" & 8" P/N: 5367 REV. AA November 03 ROTATING TOP AXLE RUNNING END ROTATING TRUCK PARTS AXLE BREAKDOWN END TRUCK P/N:

More information

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81) DIST. AUTORIZADO AIR CHAMP PRODUCTS User Manual Models FWB, LWB, MWB and HWB Brakes (i) DIST. AUTORIZADO In accordance with Nexen s established policy of constant product improvement, the specifications

More information

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept. Document No. 1788-13 Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept. 2017 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

HD Firewall Mount 850 all, S/V , C ipd #

HD Firewall Mount 850 all, S/V , C ipd # PI-394 10/10 Dedicated to improving vehicle fun, safety & performance Installation Instructions PI394 HD Firewall Mount 850 all, S/V70 1998-2000, C70 1998-2004 ipd #21.0001 SUGGESTED TOOLS Metric End Wrenches

More information

WARRANTY REGISTRATION Please complete your warranty registration to properly validate your warranty. Register your product online at: www.onlinewarranty.net LIMITED CONDITIONAL WARRANTY* Backyard Storage

More information

Installation Manual. LIFETIME LIMITED WARRANTY Warranty applies to select Residential faucets only. Pressure Balance Valve TSPVR & TSPTR

Installation Manual. LIFETIME LIMITED WARRANTY Warranty applies to select Residential faucets only. Pressure Balance Valve TSPVR & TSPTR LIFETIME LIMITED WARRANTY Warranty applies to select Residential faucets only. Installation Manual 1. TOTO warrants its faucets ( Product ) to be free from defects in materials and workmanship during normal

More information

1. DEFINITIONS 2. ORDERS, PRICES AND FEES

1. DEFINITIONS 2. ORDERS, PRICES AND FEES Exhibit C GENERAL TERMS AND CONDITIONS - INTERNATIONAL The following are the Terms and Conditions under which TRANSCORE, LP, a Limited Partnership chartered in Delaware, United States of America or its

More information

Carbon Forged Steel Fittings

Carbon Forged Steel Fittings SALES CENTER/WAREHOUSE 14496 CROGHAN PIKE P.O. BOX 330 MT. UNION, PA 17066 (814) 542-2545 (800) 345-7546 FAX (814) 542-9977 bfsales@bonneyforge.com www.bonneyforge.com PRICE SCHEDULE L-140 Effective January

More information

Carbon Forged Steel Fittings

Carbon Forged Steel Fittings BONNEY FORGE SALES CENTER/WAREHOUSE 14496 CROGHAN PIKE P.O. BOX 330 MT. UNION, PA 17066 (814) 542-2545 (800) 345-7546 FAX (814) 542-9977 TELEX 910-240-9091 E-MAIL: bfsales@bonneyforge.com WEB SITE: http://www.bonneyforge.com

More information

DSF290 TRUSS MOUNT FOR 12 TRUSS WITH 2 OUTER DIAMETER TUBING

DSF290 TRUSS MOUNT FOR 12 TRUSS WITH 2 OUTER DIAMETER TUBING DSF290 TRUSS MOUNT FOR 12 TRUSS WITH 2 OUTER DIAMETER TUBING 40" - 90" (102-229 cm) MAX 175 lb (79 kg) SF640 SF650 Mount Compatability for DSF290 SF660 ST640 ST650 ST660 SP850 FPS-1000 PS-1 PS-2 DS-VW765-LAND

More information

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017 Document No. 1788-20 Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000

More information

GF6580BH-1 PATRIOT LIBERTY QUARTER RAILS:

GF6580BH-1 PATRIOT LIBERTY QUARTER RAILS: GF6580BH-1 PATRIOT LIBERTY QUARTER RAILS: INSTALLATION & OPERATION INSTRUCTIONS FOR PATRIOT BED PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE Info: The most current version of these instructions can be

More information

Beach House Cargo Lifts Branded Product of Cargo Lift Distributors

Beach House Cargo Lifts Branded Product of Cargo Lift Distributors Beach House Cargo Lifts Branded Product of Cargo Lift Distributors Conditions of Sale Price Agreement Manufacture Suggested Retail Price (MSRP) Prices and Terms Order Processing Shipping and Delivery Warranty

More information

Pipe couplings and fittings

Pipe couplings and fittings Mech Tees - Threaded 1) 1) The Rp1/2 and Rp3/4 outlet sizes are intended for direct connection to sprinklers onlys ÄI00 / 2015-04 P11.194.611-1V DN Inch Model OD 50 2 3J 60.3 (2.37) 65 3 3J 76.1 (3.0)

More information

PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE

PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE GF6590BH-1 PATRIOT LIBERTY HALF NO-GAP HEAD RAILS: INSTALLATION & OPERATION INSTRUCTIONS FOR PATRIOT BED PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE Info: The most current version of these instructions

More information

PI /09 Dedicated to improving vehicle fun, safety & performance

PI /09 Dedicated to improving vehicle fun, safety & performance PI-383 10/09 Dedicated to improving vehicle fun, safety & performance Installation Instructions PI383 ipd Silicone Boost Tubing Kit Fits all S60 with 5 cylinder Turbo all S80 with 5 cylinder Turbo 2001-2007

More information

Fire Barrier. Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes

Fire Barrier. Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes 3 Fire Barrier Moldable Putty+ Pads Protecting Metallic and Non-Metallic Electrical Boxes This information brochure highlights requirements for UL listed, fire-rated electrical boxes located in some UL

More information

We greatly appreciate your business and promise to work hard to provide you with the highest level of service at all times.

We greatly appreciate your business and promise to work hard to provide you with the highest level of service at all times. Thank you for purchasing a Powerglide from Airlift Doors, Inc. We take great pride in the quality and workmanship of our products and stand behind our products 100%. If you have any questions or concerns

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1800-59 MicroVac Portable Cleanroom Vacuum Cleaner Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave.

More information

Shower Column SHCM Installation Guide

Shower Column SHCM Installation Guide Shower Column SHCM-2718-00 Installation Guide 1 I. Parts List: 1. Goose-neck shower arm 1 pc 12, Mounting screws 4pcs 21 2,3 Nuts 2 pc 13, Water supply hoses 2pcs 14 4,7, Rubber washer (used together 6

More information

WEST FLOORING & DESIGN (WFD)

WEST FLOORING & DESIGN (WFD) Moisture and Humidity- PLEASE READ BEFORE BEGINNING INSTALLATION Room temperature and humidity of installation area should be consistent with normal, year-round living conditions for at least a week before

More information

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm) CSM_PS-_S(R)_-31_DS_E_7_1 Separate s for Water Supply and Drainage Control in Buildings. Small, Lightweight s for Use as Built-in Components. The PS-@S(R) are separate s that allow the s to be withdrawn

More information

GC-X360S-W GC-X360S-B

GC-X360S-W GC-X360S-B GC-X360S-W GC-X360S-B Game Console Security Cover for Xbox 360S 1 date:01/22/13 #:125-9401 WARNING ENG - This product was designed to be installed on wood stud, solid concrete or cinder block walls. Before

More information

Monolithic Isolation Fittings

Monolithic Isolation Fittings Monolithic Isolation Fittings The Industry s Dual O Ring Seal Standard Tests Include: 100% Hydrostatic Pressure & Electrical Tests 100% Ultrasonic of Welds 100% Magnetic Particle of Welds 100% Dye Penetrant

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL IQ200TE and IQ300TE Thermoelectric Coolers OPERATION AND INSTALLATION MANUAL *** IMPORTANT *** PLEASE READ this manual and follow the instructions for safe and satisfactory installation and operation of

More information

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual FORM FOOTWALL (floating) Installation Manual FORM FOOTWALL (floating) OVERVIEW The Form is a UL-listed configurable footwall system. This system can include any combination of base cabinets, upper cabinets,

More information

precision pipe fittings

precision pipe fittings Precision Pipe Fittings HOKE Incorporated 405 Centura Court PO Box 4866 (29305) Spartanburg, SC 29303 Phone (864) 574-7966 Fax (864) 587-5608 www.hoke.com sales@hoke.com Index CNP Close Nipple 4 NP Hex

More information

Electrostatic Technology, Inc. A Subsidiary of Nordson Corporation

Electrostatic Technology, Inc. A Subsidiary of Nordson Corporation Electrostatic Technology, Inc. A Subsidiary of Nordson Corporation CONVENTIONAL FLUIDIZED BED MODEL CFB-64 SERIAL NUMBER 17971 INSTALLATION & OPERATING MANUAL 10/00 Phone (203) 488-8112 www.eti.nordson.com

More information

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount) INSTALLATION MANUAL FOOTWALL/SINKWALL (floor mount) OVERVIEW The Form is a UL-listed configurable footwall/sinkwall system. This system can include any combination of base cabinets, upper cabinets, wardrobes,

More information

Plexture Coating Limited Performance Labor and Material Warranty

Plexture Coating Limited Performance Labor and Material Warranty Plexture Coating Limited Performance Labor and Material Warranty T410 hereby warrants to the building owner that the Plexture materials will not delaminate, peel, crack, or chalk for a period of five (5)

More information

VILLAGIO FLOORS, INC. TOLL FREE: Fax: VILLAGIOWOODFLOORS.COM. Finish Warranty. Structural Warranty

VILLAGIO FLOORS, INC. TOLL FREE: Fax: VILLAGIOWOODFLOORS.COM. Finish Warranty. Structural Warranty Finish Warranty Villagio Floors, Inc. warrants to the original purchaser/homeowner (who owns the home in which it was installed) that the finish, when used under normal residential traffic conditions,

More information

TAYLOR FORGE STAINLESS

TAYLOR FORGE STAINLESS PRICE SCHEDULE NO. TFS 09-2011 Effective Sept. 1, 2011 Subject to change without notice TAYLOR FORGE STAINLESS ISO 9001-2008 Certified ASME Quality System Certificate Holder - Certificate #QSC 269 1984-2011

More information

ARALDITE AW 136 Resin Hardener HY 5049 EPOXY LAMINATING ADHESIVE

ARALDITE AW 136 Resin Hardener HY 5049 EPOXY LAMINATING ADHESIVE ARALDITE AW 136 Resin Hardener HY 5049 EPOXY LAMINATING ADHESIVE DESCRIPTION: Araldite AW 136 resin/hardener HY 5049 epoxy adhesive is a two-part laminating system used for fabricating skis, snowboards

More information

EJOT Solar Fastenings. Installation Manual

EJOT Solar Fastenings. Installation Manual EJOT Solar Fastenings Installation Manual Setscrew DIN 913 M10 x Lg A2 with internal hex drive SW5 Locknut DIN 985 M10 Plain washer M10 Hexagon nut M10 Precise defined depth (control) stop Washer E16/8

More information

E3X-DRT21/SRT21/CIF11

E3X-DRT21/SRT21/CIF11 for E3X-DA-N-series Fiber Amplifiers /SRT21/CIF11 CSM SRT21_CIF11_DS_E_3_2 Three New s for Fiber Amplifiers DeviceNet CompoBus/S RS-422 Note: Manufacture of the E3X-DA6-P will be discontinued in March

More information

Exterior Concrete Embedded Snow and Ice Melting System. For Concrete Walkways, Driveways and Paver Systems

Exterior Concrete Embedded Snow and Ice Melting System. For Concrete Walkways, Driveways and Paver Systems Exterior Concrete Embedded Snow and Ice Melting System For Concrete Walkways, Driveways and Paver Systems INSTALLATION and operation INSTRUCTIONS Manufactured using UL recognized components PCCED 2016

More information

Thermoelectric Cooler

Thermoelectric Cooler INSTRUCTION MANUAL Thermoelectric Cooler TE090624020, TE121024020, TE121048020, TE162024020, TE162048020, TE090624010, TE121024010, TE121048010, TE162024010, TE162048010, TE090624011, TE121024011, TE162024011

More information

Everything in its place. OWNER S MANUAL. TRINITY ECOSTORAGE 6-TIER NSF 48 x 18 x 72 WIRE SHELVING RACK w/wheels CHROME Model # TBFC-0907

Everything in its place. OWNER S MANUAL. TRINITY ECOSTORAGE 6-TIER NSF 48 x 18 x 72 WIRE SHELVING RACK w/wheels CHROME Model # TBFC-0907 Everything in its place. OWNER S MANUAL TRINITY ECOSTORAGE 6-TIER NSF 48 x 18 x 72 WIRE SHELVING RACK w/wheels CHROME Model # TBFC-0907 PARTS LIST Your TRINITY EcoStorage 6-Tier NSF Wire Shelving Rack

More information

Lithonia Lighting Terms and Conditions of Sale

Lithonia Lighting Terms and Conditions of Sale Lithonia Lighting Terms and Conditions of Sale For Shipments Within the United States Effective January 14, 2009 TERMS All Lithonia Lighting, a division of Acuity Brands Lighting, Inc. ( Lithonia Lighting

More information

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

3601 E. 34th St. Tucson, AZ USA Tel Fax Web: Equipment Type: Weld Check Analysis Software Version 4.2 System Requirements: Memory Requirements: Windows XP/Vista/Windows V7 144 MB Manual Revision Date: December 22, 2011 Serial Number This instruction

More information

User Guide M Rev A 09/15

User Guide M Rev A 09/15 User Guide 8525-0360-0M Rev A 09/15 1 Introduction Thank you for purchasing our Detecto Rescue Medical Cart. It has been manufactured with Detecto quality and reliability. Attention 1. Please read this

More information

WARNING. Introduction ! ATTENTION

WARNING. Introduction ! ATTENTION User Guide PO Box 151 Webb City, MO 64870 8525-0360-0M Rev A Ph: 417-673-4631 Fax: 417-673-5001 09/15 www.detecto.com Technical Support: Ph: 866-254-8261 tech@cardet.com 1 2 Introduction Thank you for

More information

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols. VIGO INDUSTRIES INSTALLATION GUIDE FOR STANDING SHOWER CABIN (MODEL VG06062) SAFETY PRECAUTIONS This Installation Guide uses the following symbols to indicate important information. Always observe the

More information

STEEL PIPE COUPLINGS

STEEL PIPE COUPLINGS STEEL PIPE COUPLINGS Price Sheet PC-3.11C Effective: March 28, 2011 Cancels Price Sheet PC.06.10C of June 28, 2010 FOR THE MOST CURRENT PRODUCT/PRICING INFORMATION ON ANVIL PRODUCTS, PLEASE VISIT OUR WEBSITE

More information

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain Installation, Operating and Maintenance Instructions Incognito Series Air Curtain Models: INC10036, INC10042, INC10048, INC10064, INC10072, INC10084, INC10096, INC10108, INC10120, INC10144. READ THIS OWNER

More information

Keysight 16380C Capacitance Standard Set

Keysight 16380C Capacitance Standard Set Keysight 16380C Capacitance Standard Set Operating Note Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is

More information

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628 User Manual English APC Step-Down Transformer Models: AP9626, AP9627, and AP9628 990-7820F 06/2006 Introduction Introduction The APC step-down transformers are used to convert a higher input voltage (208-200

More information

SECTION FIRE HYDRANTS

SECTION FIRE HYDRANTS SECTION 21 11 10 PART 1. GENERAL 1.1 SUMMARY: A. Work consists of furnishing and installing new fire hydrants, (boot with ductile iron retainer gland, standpipe and hydrant complete) plus constructing

More information

Heavy-Duty Aluminum Arched Ramps 10,000-Lb. Capacity Per Pair.

Heavy-Duty Aluminum Arched Ramps 10,000-Lb. Capacity Per Pair. Heavy-Duty Aluminum Arched Ramps 10,000-Lb. Capacity Per Pair. Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety

More information

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL Model # Series 7200-S Top Mounting Plate Electrical Junction Box Located Behind Removable Upper Panel Medical Gas Connections Lower Mounting Plate OVERVIEW

More information

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS Kennedy Valve A Division of McWane, Inc. AWWA PRODUCTS 1021 East Water Street Elmira, NY 14902 Phone: (607)734-2211 Fax: (607)734-3288 Fax: (800)952-4771 E-Mail: sales@kennedyvalve.com www.kennedyvalve.com

More information