UL/CSA LISTED IN BOX TM W EATHERPROOF-IN-USE R ECESSED B OXES. Arlington

Size: px
Start display at page:

Download "UL/CSA LISTED IN BOX TM W EATHERPROOF-IN-USE R ECESSED B OXES. Arlington"

Transcription

1 UL/CSA LISTED IN BOX TM W EATHEPOOF-IN-USE ECESSED B OXES

2 Save Time... Look Great with IN BOX TM No extra parts to handle or purchase. Save on labor and materials. Forget installing an electrical box and a bubble cover assembly, and a siding block on siding. Now, get it all in s One-Piece, ecessed Weatherproof-in-use IN BOX!... Non-metallic 22 cu. inch electrical box with a weatherproof-in-use cover. Bug Plugs IN BOX ships with Bug Plugs installed to keep insects from entering the box through unused cord openings. Available for brick; retrofit; new or existing vinyl siding; stucco and textured surfaces; rigid siding and foam wall systems. Fast, easy vertical or horizontal installation. The job looks great because IN BOX installs in the wall Less of it shows outside. Accepts single gang devices; no gaskets required. Clear or white paintable cover. eplacement covers sold separately in clear (not paintable) and white, textured (paintable). (See back for ordering information). Meets 2005 NEC, Section For use where a weatherproof-in-use cover is required for 15/20 amp receptacles installed outdoors. Patents pending Fax sales@aifittings.com

3 IN BOX for a variety of uses with clear or white cover! Suffix W = White cover Suffix C = Clear cover etrofit For flat surfaces 4 page Vertical DBV1W DBV1C Horizontal DBH1W DBH1C New & Existing Vinyl Siding Eliminates use of a siding block Outer flange covers cut ends of siding Fits all siding types 6 page for New Siding for Existing Siding DBVS1W DBVS1C DBV131W DBV131C DBV141W DBV141C DBV151W DBV151C DBV171W DBV171C DBHS1W DBHS1C DBH131W DBH131C DBH141W DBH141C DBH151W DBH151C DBH171W DBH171C Stucco & Textured Surfaces Holes in the flange allow stucco to bond firmly 8 page DBVM1W DBVM1C DBHM1W DBHM1C igid Siding Foam Wall Systems & Concrete Block/Stucco For cementitious/fiber lap siding 10 page Flange depth adjusts to fit different wall systems 12 page for New igid Siding for igid Siding etrofit DBVM1W DBVM1C DBV131W DBV131C DBVMA1W DBVMA1C DBHM1W DBHM1C DBH131W DBH131C New Brick Built-in anchor tabs seat IN BOX into mortar for a super secure 14 installation page DBHB1W DBHB1C 3

4 IN BOX TM for etrofit Vertical DBV1C w/ Clear Cover DBV1W w/ White Cover Horizontal DBH1C w/ Clear Cover DBH1W w/ White Cover For flat surfaces in existing construction, use the retrofit IN BOX on plywood, T-111, and other flat surfaces. Pivot Point For added convenience, covers are removable for electrical installation. eplace cover upon completion. Cover colors: Clear (not paintable) or white (paintable) Bug Plugs ship installed in all IN BOX styles to seal unused cord hole openings DBV1C Textured White cover for easy (optional) paintability Item UPC/DCI/NAED Orientation/ Unit/Std No. Mfg. # Cover Color Pkg DBV1C Vertical/clear 4 DBV1W Vertical/white 4 DBH1C Horizontal/clear 4 DBH1W Horizontal/white 4 Includes box w/ weatherproof-in-use cover, installed bug plugs, (1) standard duplex and (1) GFCI face plate, installation screws, (1) roll of caulk and NM cable connector. Our etrofit IN BOXES can also be used for Existing Siding retrofit. Just place a separate order for the siding profile adapter plate to fit your particular siding type. See pages 6-7 for installation information. DBH1W Patents pending Siding Profile Adapter Plate - Vertical Item UPC/DCI/NAED Siding Unit/Std No. Mfg. # Lap Size/Style Pkg DBV /4 & 5/16 4 DBV /2 4 DBV /8 4 DBV Dutch Lap 4 Siding Profile Adapter Plate - Horizontal Item UPC/DCI/NAED Siding Unit/Std No. Mfg. # Lap Size/Style Pkg DBH /4 & 5/16 4 DBH /2 4 DBH /8 4 DBH Dutch Lap 4 Includes installation screws and caulk Fax sales@aifittings.com

5 on Flat Surfaces 1. Cut hole. Pull wiring. 2. Apply the supplied caulk around back edges of flange. Install NM cable connector and wire, then press onto surface. 3. Attach IN BOX with stainless steel screws (provided). 4. Install wiring device. IN BOX Saves Time. Looks Great! Finished! The IN BOX accepts most single gang wiring devices, and uses a standard indoor wall plate. See chart on back Suffix W = White cover Suffix C = Clear cover 5

6 IN BOX TM for New Vinyl Siding The one-piece IN BOX eliminates the need to install an electrical box and a siding block, and a bubble cover assembly. Outer flange covers cut ends of siding IN BOX for New Siding includes box w/ weatherproof-in-use cover, installed bug plugs, (1) standard duplex and (1) GFCI face plate, installation screws, and (1) NM cable connector. Outer flange covers cut ends of siding Fits all siding types Item UPC/DCI/NAED Orientation/ Unit/Std No. Mfg. # Cover Color Pkg DBHS1W DBVS1C Vertical/clear 4 DBVS1W Vertical/white 4 DBHS1C Horizontal/clear 4 DBHS1W Horizontal/white 4 DBVS1C for Existing Siding We fitted our retrofit box with a siding profile adapter plate for use on existing siding! DBV141W Item UPC/DCI/NAED VETICAL Siding Unit/Std No. Mfg. # Cover Color Lap Size Pkg DBV131C Clear 1/4, 5/16 4 DBV131W White 1/4, 5/16 4 DBV141C Clear 1/2 4 DBV141W White 1/2 4 DBV151C Clear 5/8 4 DBV151W White 5/8 4 DBV171C Clear Dutch Lap 4 DBV171W White Dutch Lap 4 Item UPC/DCI/NAED HOIZONTAL Siding Unit/Std No. Mfg. # Cover Color Lap Size Pkg Siding profile adapter plate allows use of etrofit IN BOX on any siding type. DBH131C Clear 1/4, 5/16 4 DBH131W White 1/4, 5/16 4 DBH141C Clear 1/2 4 DBH141W White 1/2 4 DBH151C Clear 5/8 4 DBH151W White 5/8 4 DBH171C Clear Dutch Lap 4 DBH171W White Dutch Lap 4 IN BOX Components for Existing Siding (Bug plugs, face plates not shown. Includes 2 rolls of caulk) Fax sales@aifittings.com

7 For all Siding Types 1. Cut hole in substrate. Pull wiring. 2. Install NM cable connector and wire... attach IN BOX to substrate. 3. Install siding, inserting the cut ends of the siding under the outer flange of the IN BOX. 4. Install wiring device. IN BOX accepts most single gang wiring devices, and uses a standard indoor wall plate. A B A B 1. Using the siding profile adapter plate as a template, cut hole in existing siding. Pull wiring. 2A. Apply caulk around edges of back of adapter. Press onto siding. B. Attach adapter to siding with short screws (supplied) through the holes noted above. Trim excess caulk as needed. 3A. Apply caulk to reverse side of IN BOX flange. B. Install NM cable connector and wire, then attach with long screws (provided). Trim excess caulk as needed. Install wiring device. IN BOX for Existing Siding includes box w/ weatherproof-in-use cover, siding profile adapter plate, installed bug plugs, (1) standard duplex and (1) GFCI face plate, (2) sets installation screws, (2) rolls caulk and (1) NM cable connector. See chart on back Suffix W = White cover Suffix C = Clear cover 7

8 IN BOX TM for Stucco,Textured Surfaces For stucco over masonry or wood construction Holes in the flange allow stucco to bond firmly Ships with disposable mud cover in place Includes a plastic block bushing for concrete block applications Ships with disposable mud cover in place Weatherproofin-use Cover DBVM1C Item UPC/DCI/NAED Orientation/ Unit/Std No. Mfg. # Cover Color Pkg DBVM1C Vertical/clear 4 DBVM1W Vertical/white 4 DBHM1C Horizontal/clear 4 DBHM1W Horizontal/white 4 Item UPC/DCI/NAED Description Unit/Std No. Mfg. # Pkg FXC Plastic 25 Block Bushing IN BOX for new stucco and textured surfaces includes box w/ weatherproof-in-use cover, installed bug plugs, (1) standard duplex and (1) GFCI face plate, (1) NM cable connector, FXC3 block bushing w/ washer, and mud cover. Holes in flange allow stucco or textured coating to bond DBHM1W Installation on Wood 1. Make hole in plywood. Pull wiring through opening. 2. Install NM cable connector and wire. Attach IN BOX to plywood. 3. IN BOX...ready for stucco Fax sales@aifittings.com

9 Masonry Construction Installation 1. Make hole in block. Pull wiring through plastic block bushing and opening in block. 2. Block bushing mounts to interior side of block. IN BOX Stucco 3. Install NM cable connector and wire. Attach recessed IN BOX to concrete block. The holes in the flange allow stucco to bond firmly. Mounts to block NM Cable Connector 4. Install wiring device. IN BOX accepts most devices, and a standard indoor wall plate. FXC3 NM Cable FXC3 Block Bushing Washer Cable (ready for assembly of furring strips & drywall) The FXC3 plastic block bushing mounts to concrete block and protects cable as it passes through the block. It comes with the IN BOX for new stucco/textured surfaces. It s also sold separately. Cutaway showing IN BOX and plastic block bushing mounted in concrete block. DBVM1W w/ White Cover DBVM1C w/ Clear Cover See chart on back Suffix W = White cover Suffix C = Clear cover 9

10 IN BOX TM for igid Siding Vertical DBVM1C w/ Clear Cover DBVM1W w/ White Cover Horizontal DBHM1C w/ Clear Cover DBHM1W w/ White Cover For cementitious/fiber rigid lap siding; there s an IN BOX for new construction, and one for retrofit. DBHM1W 1. Install NM cable connector and wire. Attach IN BOX to stud. DBVM1C Item UPC/DCI/NAED Orientation/ Unit/Std No. Mfg. # Cover Color Pkg DBVM1C Vertical/clear 4 DBVM1W Vertical/white 4 DBHM1C Horizontal/clear 4 DBHM1W Horizontal/white 4 IN BOX for new rigid siding includes box w/ weatherproof-in-use cover, installed bug plugs, (1) standard duplex and (1) GFCI face plate, (1) NM cable connector, FX3 block bushing w/ washer, and mud cover. for Existing igid Siding 1. Cut opening in plywood. Pull wiring. Vertical DBV131C w/ Clear Cover DBV131W w/ White Cover Horizontal DBH131C w/ Clear Cover DBH131W w/ White Cover DBH131W Item UPC/DCI/NAED Orientation/ Unit/Std No. Mfg. # Cover Color Pkg DBV131C Vertical/clear 4 DBV131W Vertical/white 4 DBH131C Horizontal/clear 4 DBH131W Horizontal/white 4 IN BOX for Existing igid Siding includes box w/ weatherproof-in-use cover, profile adapter, bug plugs, (1) standard duplex and (1) GFCI face plate, (2) sets installation screws, (2) rolls caulk and (1) NM cable connector. 1. Using the siding profile adapter plate as a template, cut hole in existing siding. Pull wiring Fax sales@aifittings.com

11 New Construction Installation Method 1 2. Install moisture barrier around IN BOX per manufacturer s instructions. 3. Cut rigid siding to fit around IN BOX. Caulk around box. 4. Install wiring device and reinstall cover (if removed for installation). New Construction Installation Method 2 2. Install NM cable connector and wire. Attach IN BOX to substrate, then install moisture barrrier around box as shown above. 3. Cut rigid siding to fit around IN BOX. Caulk as above for a great looking job! 4. Install wiring device and reinstall cover (if removed for installation). IN BOX ships with installed bug plugs (not shown in photo). 2. Apply caulk around edges of back of adapter (see page 7 for photo guide). Press onto siding. Attach adapter to siding with (supplied) short screws through the holes noted above. Trim excess caulk as needed. 3. Apply caulk to reverse side of IN BOX flange. Install NM cable connector and wire, then attach with long screws (provided). Trim excess caulk as needed. Install wiring device. 4. Finished! See chart on back Suffix W = White cover Suffix C = Clear cover 11

12 IN BOX TM for Foam Wall Systems Vertical DBVMA1C w/ Clear Cover DBVMA1W w/ White Cover The flange depth is adjustable to fit any foam board thickness or custom finish in concrete block and stucco applications keeping IN BOX recessed inside the wall. Our low profile adjustable IN BOX protrudes from the wall just enough for a neat, clean appearance! Flange depth adjusts to accommodate finishes from 1/4" to 2.5" thick in walls from 2.75" to 5" deep. DBVMA1W Ships with disposable mud cover in place Item UPC/DCI/NAED Orientation/ Unit/Std No. Mfg. # Cover Color Pkg DBVMA1C Vertical/clear 4 DBVMA1W Vertical/white 4 IN BOX for Foam Wall Systems includes box w/ weatherproof-in-use cover, bug plugs, (1) standard duplex and (1) GFCI face plate, (1) NM cable connector, (4) screws and a mud cover Fax sales@aifittings.com

13 Adjustable Flange Depth! emove screw. Adjust flange depth. Insert screw in the appropriate opening to hold flange securely in place. Flange in position for thin foam board or finish thickness Flange depth opened to accommodate thicker foam board or finishes photo w/ thin EIFS board 2" Foam Board 1/2" Foam Board Note: Moisture barrier not shown on either cutaway. Check system manufacturer s specifications for details. The Flange Depth on this IN BOX adjusts to fit any foam thickness. 13

14 IN BOX TM for New Brick Horizontal DBHB1C w/ Clear Cover DBHB1W w/ White Cover Our IN BOX for new brick offers features that get the job done fast and right! Built-in anchor tabs seat IN BOX into mortar for a super secure installation Installed mud cover extends all the way over the flange, providing maximum protection during construction. Discard when construction is complete. DBHB1C Anchor tabs seat the IN BOX into the mortar for a super secure installation. Item UPC/DCI/NAED Orientation/ Unit/Std No. Mfg. # Cover Color Pkg DBHB1C Horizontal/clear 4 DBHB1W Horizontal/white 4 IN BOX for new brick includes box w/ weatherproofin-use cover, installed bug plugs, (1) standard duplex and (1) GFCI face plate, (1) NM cable connector, and mud cover. eplacement covers for IN BOX sold separately clear (not paintable) and white (paintable). (See back for details) Fax sales@aifittings.com

15 Great Ideas. Our oversized, installed mud cover offers maximum protection because it extends over the entire flange. Save Time... with Look Great IN BOX TM 15

16 ETOFIT NEW CONSTUCTION Catalog Cover UPC/DCI/NAED Mounting Std Number Color Mfg # Orientation Uses Pkg for Flat surfaces DBV1C Clear Vertical For 4 DBV1W White Vertical FLAT SUFACES 4 DBH1C Clear Horizontal 4 DBH1W White Horizontal 4 Siding Profile Adapter Plate Converts ETOFIT IN BOX for Use on Existing Siding DBV131 N/A Vertical For 1/4" & 5/16" 4 DBV141 N/A Vertical For 1/2" siding 4 DBV151 N/A Vertical For 5/8" siding 4 DBV171 N/A Vertical For dutch lap siding 4 DBH131 N/A Horizontal For 1/4" & 5/16" 4 DBH141 N/A Horizontal For 1/2" siding 4 DBH151 N/A Horizontal For 5/8" siding 4 DBH171 N/A Horizontal For dutch lap siding 4 For Existing Vinyl Siding DBV131C Clear Vertical For 1/4" & 4 DBV131W White Vertical 5/16" siding 4 DBV141C Clear Vertical For 1/2" 4 DBV141W White Vertical siding 4 DBV151C Clear Vertical For 5/8" 4 DBV151W White Vertical siding 4 DBV171C Clear Vertical For dutch lap 4 DBV171W White Vertical siding 4 DBH131C Clear Horizontal For 1/4" & 4 DBH131W White Horizontal 5/16" siding 4 DBH141C Clear Horizontal For 1/2" 4 DBH141W White Horizontal siding 4 DBH151C Clear Horizontal For 5/8" 4 DBH151W White Horizontal siding 4 DBH171C Clear Horizontal For dutch lap 4 DBH171W White Horizontal siding 4 For igid Lap Siding DBV131C Clear Vertical For 4 DBV131W White Vertical CEMENTITIOUS 4 DBH131C Clear Horizontal IGID LAP 4 DBH131W White Horizontal SIDING 4 Catalog Cover UPC/DCI/NAED Mounting Std Number Color Mfg # Orientation Uses Pkg For New Siding DBVS1C Clear Vertical 4 DBVS1W White Vertical For any type of 4 DBHS1C Clear Horizontal NEW SIDING 4 DBHS1W White Horizontal 4 For Stucco, Textured Surfaces DBVM1C Clear Vertical 4 DBVM1W White Vertical For STUCCO 4 DBHM1C Clear Horizontal and TEXTUED 4 DBHM1W White Horizontal SUFACES 4 Includes FXC3 plastic block bushing For Use Where Stucco Thickness Varies DBVMA1C Clear Vertical For CONCETE 4 DBVMA1W White Vertical BLOCK & STUCCO 4 w/ Fully Adjustable Flange Depth For igid Lap Siding DBVM1C Clear Vertical For 4 DBVM1W White Vertical CEMENTITIOUS 4 DBHM1C Clear Horizontal IGID LAP SIDING 4 DBHM1W White Horizontal 4 For Foam Wall Systems w/ Fully Adjustable Flange Depth DBVMA1C Clear Vertical For FOAM 4 DBVMA1W White Vertical WALL SYSTEMS 4 For Brick DBHB1C Clear Horizontal NEW 4 DBHB1W White Horizontal BICK 4 eplacement Covers Item UPC/DCI/NAED Cover Orientation/ Unit/Std No. Mfg. # Cover Color Pkg DBVC Vertical/clear 10 DBVW Vertical/white 10 DBHC Horizontal/clear 10 DBHW Horizontal/white 10 Bushing for Concrete Block Item UPC/DCI/NAED Description Unit/Std No. Mfg. # Pkg FXC Plastic Bushing 25 Need replacement covers or extra plastic bushings? Covers available in clear (not paintable) or white (paintable) Order them separately! IN BOX TM 1 Stauffer Industrial Park Scranton, PA / Fax 570/ Industries, Inc./IN BOX 0705 Meets 2005 NEC, Section For use where a weatherproof-in-use cover is required for 15/20 amp receptacles installed outdoors. Distributed by

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

22.1 USED FOR: MATERIALS: all regular length 22 components stainless steel tool, silicon protective cover. DESCRIPTION

22.1 USED FOR: MATERIALS: all regular length 22 components stainless steel tool, silicon protective cover. DESCRIPTION USED FOR: MATERIALS: all regular length 22 components stainless steel tool, silicon protective cover. DESCRIPTION 45 (1.7 ) The 22 is a complete suite of interior wall accessories that challenge the traditional,

More information

The better way to build TM. Installation Manual NAILBASE PANELS

The better way to build TM. Installation Manual NAILBASE PANELS The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS Insulation First Revison October 2016 DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS 1. General Information This Guide describes the use of Kingspan GreenGuard DC14 Drainage

More information

Flush Service Floor Boxes

Flush Service Floor Boxes Flush Service Floor Boxes PRODUCT SPECIFICATION: Flush Service Floor Boxes PART 1: Overview Considerations when writing specifications: Floor boxes are manufactured in various sizes, configurations and

More information

Wall studs. Wall Studs

Wall studs. Wall Studs 15 Box To Stud Fastener Attaches with screws to metal studs. BB1 supports electrical box. BG series features Guide-Rite design. BP series features push-type design. 78101118145 BB1 Electrical Box 100 Support

More information

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit FreeStyle Linear Drain with Full Mortar Bed Adapter Kit U.S. Patent No. 8,474,068 Patents Pending: Canada & EP Publication No. 2354339 Discard Linear Drain installation instructions and refer to these

More information

Special Applications. Dorn Equipment, Corporation 27 Upham Street Melrose, MA Phone: Fax:

Special Applications. Dorn Equipment, Corporation 27 Upham Street Melrose, MA Phone: Fax: Special Applications Outdoor Protection When using the FIRSTO units outdoors, or wherever vapor or moisture barrier is needed, an application of FIWA sealant is used. The sealant should be applied to any

More information

PC-PH SERIES BTUH

PC-PH SERIES BTUH C O M I T A L E N A T I O N A L I N C. PC-PH SERIES 7000 18000 BTUH Installation Instructions Comitale National Inc. 1683 B Winchester Road Bensalem, PA 19020 215-244-9650 Fax: 215-244-9679 email: sales@comitalenational.com

More information

MASONRY ANCHORS AND CONNECTORS May 6, 2014

MASONRY ANCHORS AND CONNECTORS May 6, 2014 Page - 1 This section includes specification text to assist in describing a variety of masonry anchors, connectors, and accessories intended for masonry construction. This document contains prepared master

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092216 - NON-STRUCTURAL METAL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Architectural Wall Products Guide Specifications

Architectural Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is

More information

UNIVERSAL BRACKET. Shown in red color for illustration purposes. Bracket can be painted to match panels.

UNIVERSAL BRACKET. Shown in red color for illustration purposes. Bracket can be painted to match panels. US PATENT PENDING #62/536,219 Shown in red color for illustration purposes. Bracket can be painted to match panels. (15) 79-6500 1515 VALLEJO ST, SAN FRANCISCO, CA 9109 17 3 17 SIMPLE, EFFICIENT, FLEXIBLE

More information

Thin Architectural Splitface Block Veneer Specification Guide

Thin Architectural Splitface Block Veneer Specification Guide Thin Architectural Splitface Veneer System with AccuTab Technology R Thin Architectural Splitface Block Veneer Specification Guide Section 04711: Manufactured Concrete Veneer Use this specification guide

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Southwest Windpower, Inc. 1801 W. Route 66 Flagstaff, Arizona 86001 Phone: (928) 779-9463 Fax: (928) 779-1485 E-mail: info@windenergy.com Web: www.windenergy.com

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Receptacles,

More information

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. Build walls and ceilings with a strong base, sturdy reinforcements and much more with Phillips extensive line of high quality products. As a single source

More information

New Veneers Allow Greater Flexibility

New Veneers Allow Greater Flexibility New Veneers Allow Greater Flexibility A number of new veneer systems are being used with exterior insulation or standard insulation batts to create panels that are easily applied, provide outstanding insulation

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF

More information

Section 5 Panels & Accessories

Section 5 Panels & Accessories Contents Section 5 Panels 74-76 Stiffener/Handle 79 Wire Mesh 75 Sliding Door Guide 80 Panel Mounting locks 77 Rolling Door Guide 81 Mesh Retainers 78 ifold Door Glide 82-83 Mesh Clamp 79 T-Clips 84 Panels

More information

BioPrism Solid Surface

BioPrism Solid Surface Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS SECTION 16711-27 05 28.33 PART 1 - GENERAL 1.01 SUMMARY A. This section includes Labor, materials and equipment necessary to complete the installation required for the items specified under this Section,

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

Trench Duct Class Catalog 5230CT9601R10/08

Trench Duct Class Catalog 5230CT9601R10/08 5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11

More information

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS PART 1 - GENERAL 01.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification sections, apply to work of this Section.

More information

Technical Data Sheet

Technical Data Sheet Technical Data Sheet ProGUARD Concrete Insulated Sheathing Specifications & Installation Table Of Contents Product Description... pg. 1 Basic Use... pg. 1 Exterior Finishes... pg. 1 Standard Sizes... pg.

More information

Impression Graphic panels

Impression Graphic panels Impression Graphic panels Installation Guidelines 6003.I Rev. 02 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to

More information

OVERHEAD SERVICES - SECONDARY

OVERHEAD SERVICES - SECONDARY OVERHEAD SERVICES - SECONDARY Contents - Overhead Services... O-1 General Requirements for Overhead Service... O-2 Names of Parts for Overhead Service... O-3 Service Attachment on an Unguyed Service Mast...

More information

SECTION NON--STRUCTURAL METAL FRAMING

SECTION NON--STRUCTURAL METAL FRAMING The Collective Voice of America s Steel Framing Industry The Steel Framing Industry Association (SFIA) is dedicated to expanding the market for cold-formed steel in construction through programs and initiatives

More information

GAF EnergyGuard Polyiso Wall Sheathing

GAF EnergyGuard Polyiso Wall Sheathing From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:

More information

DMX AG AIR-GAP MEMBRANE. Section Damproofing and Waterproofing

DMX AG AIR-GAP MEMBRANE. Section Damproofing and Waterproofing DMX AG AIR-GAP MEMBRANE Section 07 10 00 Damproofing and Waterproofing NOTE TO SPECIFIER: These specifications were current at the time of publication but are subject to change at any time without notice.

More information

AMP Low Voltage Landscape Lighting AMP LED Hardscape Lights AHS-67XX Series

AMP Low Voltage Landscape Lighting AMP LED Hardscape Lights AHS-67XX Series INSTALLATION & MAINTENANCE GUIDE AMP Low Voltage Landscape Lighting AMP LED Hardscape Lights AHS-67XX Series Help Hotline: 1-813-978-3900 Mon-Fri 9am-6pm (EST) INSTALLATION & MAINTENANCE GUIDE! AMP LED

More information

Smart Panel System The Health Care Specialist

Smart Panel System The Health Care Specialist Smart Panel System The Health Care Specialist Smart Panel System Produces fully relocatable smart panel systems (BHU) The Bed Head Unit designed and manufactured off site with all services factory installed,

More information

Product Brochure. Masonry Drainage and Ventilation Products

Product Brochure. Masonry Drainage and Ventilation Products Product Brochure Masonry Drainage and Ventilation Products Every building professional who works with masonry knows the #1 reason masonry buildings fail is moisture trapped behind the veneer. Professionals

More information

BioPrism Solid Surface

BioPrism Solid Surface Please read all instructions before installing products. STORAGE & HANDLING: Check for damage that may have occurred during transit. Keep receptor flat on pallet, as it was shipped, until ready to install.

More information

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 8 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 8 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

Install Instruction LOOP RECESSED

Install Instruction LOOP RECESSED LOOP RECESSED T F W 604.549.9379 604.549.9555 fluxwerx.com Install Instruction 1 X 1 6" X 1 6" X 1.5 ATTENTION: This installation guide does not apply to Loop Recessed 1x2, 2x2, 1x4, 2x4, 6"x2 and 6"x4.

More information

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS 2.18 INTERIOR & EXTERIOR FINISHES 2.18.1 VAPOR & AIR BARRIERS The Logix wall assembly has no need for an additional vapor barrier, the solid concrete core covered with the low permeance EPS (Type II) foam

More information

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels Glasboard Liners installation details Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION These guidelines are provided

More information

Form Liners. Architectural Concrete. Form Liners

Form Liners. Architectural Concrete. Form Liners When it is time to choose concrete formliners, make your first choice Dayton Superior. For stock or custom orders, we have you covered. Choose from three product lines: TherMOform, Vinyltite and Elasto-TEX.

More information

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using

More information

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines ZIP System R12 Sheathing INSTALLATION MANUAL Contents 02 ZIP System R12 Sheathing General Notes, Guidelines and Limitations 03 ZIP System R12 Sheathing Installation 05 ZIP System R12 Sheathing Non Structural

More information

Rough-in frame and flush-mount panel installation instructions

Rough-in frame and flush-mount panel installation instructions Welch Allyn, Inc. 3 State Street Road Skaneateles Falls, NY 33 USA Rough-in frame and flush-mount panel installation instructions 726080 DIR 8002869 Ver. A Revised 206- The Welch Allyn In-Floor Scale models

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE Environmental StoneWorks specification guideline should be used to assist design professionals in the preparation of projects. Edit and delete items that may not be applicable. Verify all referenced section

More information

Guide Specification. Dayton Superior, plastic and elastomeric architectural form liners. Select paragraphs below applicable to project.

Guide Specification. Dayton Superior, plastic and elastomeric architectural form liners. Select paragraphs below applicable to project. Guide Specification SECTION 03361 ARCHITECTURAL FORM LINERS Dayton Superior, plastic and elastomeric architectural form liners. This section is based on a system of Dayton Superior, which is located at:

More information

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips)

Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIPS Installation Manual Instruction and Safety Manual Resilient Sound Isolation Clips (SIC Clips) SOUND ISOLATION CLIP SPECIFICATIONS Width...1.00 inch Height...1.06 inch Length...3.86

More information

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION S T U D S H E A R CONNECTOR STUD SHEAR CONNECTOR APPLICATION Design for Composite Structural Action Exterior ashlar-type masonry veneer, typically of clay brick or concrete block masonry, are commonly

More information

S966SP Cover 1G Gfci/Deco Wet Loc Vert Metal Gy. Material, Color, and Finish Color Gray 0 ELECTROSTATICALLY PAINTED BAKED POWDER COATED

S966SP Cover 1G Gfci/Deco Wet Loc Vert Metal Gy. Material, Color, and Finish Color Gray 0 ELECTROSTATICALLY PAINTED BAKED POWDER COATED 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 S966SP Cover 1G Gfci/Deco Wet Loc Vert Metal Gy Catalog Number Manufacturer Description Weight per unit Product Category

More information

INSTALLATION MANUAL KOCH

INSTALLATION MANUAL KOCH INSTALLATION MANUAL KOCH TECHNICAL SYSTEMS GROUP PRE-FAB ACOUSTICAL/THERMAL PANELS AND ENCLOSURES GEORGE KOCH SONS, LLC TECHNICAL SYSTEMS GROUP 10 South Eleventh Avenue Evansville, Indiana 47744 812-465-9600

More information

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions Thank you for purchasing the Genesis Dura-Max Brick Panel system for your project. The system allows you to have the look

More information

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip Resilmount A237R Furring channel sound isolation clip Installation Instructions Another Quality Building Product Installation A237R SPECIFICATIONS Width: 1-3/8 eight (including rubber): 1-1/16 Length:

More information

SPECIFICATION GUIDELINE

SPECIFICATION GUIDELINE SPECIFICATION GUIDELINE Environmental Stoneworks Corporate Office 6300 East Stapleton Drive South Denver, CO 80216 Phone (303) 309-3040 Fax (303) 309-3059 www.estoneworks.com Environmental Stoneworks specification

More information

Before You Get Started, You Will Need

Before You Get Started, You Will Need LiteForm forming components should only be assembled by workers who have been properly trained. It is the installer s responsibility to make sure that training is done before construction begins. Serious

More information

4-PIECE SHOWER WITH E-Z Pin INSTALLATION

4-PIECE SHOWER WITH E-Z Pin INSTALLATION 4-PIECE SHOWER WITH E-Z Pin INSTALLATION Suggested Tools Please consult all local and state building codes and read the entire installation instructions prior to beginning the installation of this unit

More information

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits. SECTION 09 2216 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and

More information

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1 FIRESTOP JOINT SPRAY CFS-SP WB SILICONE JOINT SPRAY CFS-SP SIL F-RATING 2-HR. 2-HR. T-RATING -HR. -HR. APPLICATION THICKNESS PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table /8" WET FILM (/6"

More information

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing INSTALLATION INSTRUCTION FOR SINGLE-HUNG AND FIXED WINDOW REPLACEMENT using FLUSH FLANGE Installation Instructions for replacing windows in a Typical Stucco Application. These instructions were developed

More information

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars SECTION 04850 (04 40 00) MSI PRECAST STONE VENEER SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. MSI Precast Stone Veneer for exterior and interior vertical surfaces. 1.2 RELATED SECTIONS Specifier Notes:

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079) WET FILM ± 7.5 ± 5 Design No. CEJ 27 P (HI/JS 20-05) Table. CONCRETE FLOOR ASSEMBLY: Max. two-hour rated concrete floor assembly made from either lightweight or normal weight concrete with a density of 00-50 pcf, with a

More information

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual FORM HEADWALL (floor mount) Installation Manual FORM HEADWALL (floor mount) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated

More information

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver. The Knife Edge Cove is a modular lighting system consisting of two parts: 1- An aluminum fixture housing extrusion 2- Drop-in lighting modules The fixture will provide a continuous knife edge architectural

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 092216 - COLD FORMED STEEL FRAMING - NON-STRUCTURAL (CFSF-NS) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 ACTION

More information

4-PIECE SHOWER & TUB/SHOWER w/ E-Z Pin INSTALLATION

4-PIECE SHOWER & TUB/SHOWER w/ E-Z Pin INSTALLATION 4-PIECE SHOWER & TUB/SHOWER w/ E-Z Pin INSTALLATION Suggested Tools Please consult all local and state building codes and read the entire installation instructions prior to beginning the installation of

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Evolution Series. 6" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 6 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 10 14 23 - PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Raceway Solutions TM. Conventional Underfloor Duct. Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System

Raceway Solutions TM. Conventional Underfloor Duct. Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System The Raceway Solutions System is an in-slab wire management product for delivering power, voice and data services

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 09260 - A. Metal stud wall framing. Denoted on drawings as "metal studs". B. Metal channel ceiling framing. C. Acoustic insulation and sealant. D. Cementitious

More information

RC4 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005

RC4 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005 RC4 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: 1 001 636 R2 Updated April 2005 Wiremold Electrical Systems conform to and should be installed and properly grounded in compliance

More information

ProGUARD Guide Specification

ProGUARD Guide Specification ProGUARD Guide Specification MANUFACTURER Section: 072100 Insulating Sheathing T.Clear Corporation 3255 Symmes Rd. Hamilton, OH 45015 Phone: 800-544-7398 Phone: 513-870-9246 Fax: 513-870-9606 072113 Cementitious

More information

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips)

Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) Installation Guide and Safety Manual Resilmount A237R (Resilient Sound Isolation Clips) 3" RESILMOUNT A237R SPECIFICATIONS 1d " f" Width...1.375 inch Height...3.25 inch Depth...1.125 inch Weight....025

More information

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work. SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Installation Guidelines

Installation Guidelines Installation Guidelines The Vertibreak Wall System: Installation Guidelines Rainscreen Insulation for New or Retrofit Construction Applications Vertibreak rainscreen insulation is an expanded polystyrene

More information

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 4CS12 4CS-1/2 4X1-7/8D Handybox Appleton/Oz Gedney Catalog Number 4CS12 Manufacturer Appleton/Oz

More information

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8. Model P36-NG10 P36-LP10 P36E-NG10 P36E-LP10 Fuel Type Natural Gas Propane Natural Gas Propane Gas Fireplaces P36-10 / P36E-10 Gas Fireplace Minimum Supply Pressure 5 W.C. (1.25 kpa) 12 W.C. (3.00 kpa)

More information

University Apartments on Brooklyn PROJECT MANUAL

University Apartments on Brooklyn PROJECT MANUAL Section 122100 Horizontal Louver Blinds University Apartments on Brooklyn PART 1 - GENERAL 1.1 SECTION INCLUDES A. Horizontal slat louver blinds. B. Operating hardware. 1.2 RELATED SECTIONS A. Section

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

Ubau Flo Shower Element Installation Manual

Ubau Flo Shower Element Installation Manual Ubau Flo Shower Element Installation Manual The information pertained within this guide is for reference only and does not supersede instructions from other product manufacturers or building codes. Always

More information

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual FORM HEADWALL (floating) Installation Manual FORM HEADWALL (floating) OVERVIEW The Form is a UL-listed configurable headwall system. This system includes multiple horizontal equipment channels integrated

More information

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth 28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1

More information

Dist. by: BEST MATERIALS Ph:

Dist. by: BEST MATERIALS Ph: Dist. by: BEST MATERIALS Ph: 800-474-7570 www.bestmaterials.com Email: Sales@BestMaterials.com FLASHING SYSTEM ENGINEERED PRODUCT SYSTEMS PRODUCT BROCHURE Distributed by: BEST MATERIALS Distributed by:

More information

SECTION PATIENT BED SERVICE WALLS

SECTION PATIENT BED SERVICE WALLS PART 1 GENERAL 1.1 DESCRIPTION: SECTION 10 25 13 PATIENT BED SERVICE WALLS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Due to the very specialized nature of Patient Wall

More information

Schluter -KERDI-DRAIN

Schluter -KERDI-DRAIN Schluter -RONDEC Finishing and edge-protection profile with a rounded reveal surface. Schluter -RONDEC is a finishing and edge-protection profile for tiled edges and outside corners of tiled surfaces.

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

SECTION EXPANSION JOINT COVER ASSEMBLIES

SECTION EXPANSION JOINT COVER ASSEMBLIES SECTION 07 95 13 EXPANSION JOINT COVER ASSEMBLIES SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Do not use aluminum, brass, or bronze

More information

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips)

Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips) Installation Guide and Safety Manual QuietClip (Resilient Sound Isolation Clips) 1d" 2 2" 1 4" f" QUIETCLIP SPECIFICATIONS Width...1.25 inch Height...4.25 inch Depth...1 inch Weight....025 lbs Max Spacing...48

More information

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 48 (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for

More information

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS Stucco Flange (Jump Frame) Install Although all possible measures have been taken to insure the accuracy of the material presented, WIXSYS, and

More information

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board Perimeter Relief and Control Joints in Fire-Rated Gypsum Board In multi-family residential construction, involving fire-rated assemblies stress relief in the firerated assemblies is important, but often

More information

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS ENCLOSURE MODEL 90566400 FOR INSERT MODEL 5660NA And ENCLOSURE MODEL 90566000 FOR INSERT MODEL 5660 STANDARD KEEP THESE INSTRUCTIONS FOR FUTURE USE

More information

Plastic Floor Box. Wiring Device-Kellems

Plastic Floor Box. Wiring Device-Kellems Plastic Floor Box Wiring Device-Kellems Plastic Floor Boxes by Hubbell: The Inside Story is Outstanding For the real story on plastic floor boxes, start on the inside. Because, while all plastic floor

More information

INSTALLATION GUIDE PLEASE READ ENTIRE INSTRUCTION MANUAL BEFORE PROCEEDING!

INSTALLATION GUIDE PLEASE READ ENTIRE INSTRUCTION MANUAL BEFORE PROCEEDING! DURA - TRENCH INSTALLATION GUIDE This guide is intended to aide in the installation of Dura-Trench systems. There are many different applications and situations for the use of this product and the installation

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

SECTION ACOUSTICAL PANEL CEILINGS

SECTION ACOUSTICAL PANEL CEILINGS SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements: