Provincial Park Cottage Subdivision Development Directive

Size: px
Start display at page:

Download "Provincial Park Cottage Subdivision Development Directive"

Transcription

1 June 2012 Provincial Park Cottage Subdivision Development Directive The intent of the following Development Directive is to establish consistent standards for provincial park cottage subdivisions. 1. Buildings & Structures - construction requirements: No more than one dwelling on any surveyed lot; No building or structure shall be constructed within the following setback areas: a) within 6 m (20 ft) of the front of any surveyed lot; b) within 1.5 m (5 ft) of the back of any surveyed lot; c) within 1.5 m (5 ft) of other boundaries of any surveyed lot; and d) setbacks not applicable to leases relying on metes and bounds (non surveyed) only buildings & structures of 9.2 m2 (100 ft2) or less and on skids (must be movable and not permanent) will be allowed in the 1.5 m (5 ft) side/back setback areas; it is the lessee s responsibility to relocate any offending building or structure outside of above mentioned setback areas; and all existing buildings and structures are required to be brought into compliance within a reasonable timeframe as determined by the local park manager; maximum of one year. Grandfathering: Permanent structures situated on the property prior to 2008 will be grandfathered with a development freeze as long as the structure does not pose a threat to public safety. Non-compliant structures will be reviewed upon application of a new building permit and will be required to be brought into compliance. There will not be a grandfathering option for any non- compliant structures situated on the property after These structures will be required to be brought into compliance. 2. Guest Houses/Bunk Houses: One guest house/bunk house or sleeping quarters per lot is allowed as long as: the requirements for residential occupancies are met; must adhere to the National Building Code of Canada (NBC) as well as The Uniform Building and Accessibility Standards Act (The UBAS Act); detached structure containing sleeping quarters but does not contain cooking or plumbing facilities; may not exceed the size of the cabin or 30m2 (320ft2); and occupancy of any new or existing guest houses/bunk houses or sleeping quarters will not be permitted until they meet the minimum life safety requirements of the NBC.

2 Page 2 3. Ready to Move (RTM) Homes, Modular Homes, Mobile Homes, Manufactured Homes & Yurts: Modular Homes, Mobile Homes, Manufactured Homes & Yurts are not permitted in cottage subdivisions; and only park pre-approved CSA ready to move (RTM) homes will be permitted; please submit design drawings to park official prior to approval; and only park pre-approved used homes will be permitted; please submit design drawings to park official prior to approval. 4. Maximum Aggregate Building Area (includes all buildings or structures dwelling and garage): This is a cumulative area of all buildings or structures and only refers to building or footprint area, not floor area. Maximum of 50% total lot coverage; and May not exceed 3 accessory buildings. 5. Maximum height of Dwelling units: 9.2 m (30 ft) from lowest finished grade to the peak of the roof; and Exit requirements from stories must conform to the NBC. 6. Accessory Building Restrictions: The following restrictions apply to all accessory buildings. No accessory building may be constructed, erected or moved on to any site prior to the time of construction of the principal building to which it is accessory; Maximum of 3 accessory buildings permitted subject to maximum area above (guest house Max 320 ft2); 3 walls/roof/floor is considered a fixed building (small wood sheds enclosed & portable garages are considered an accessory building; Maximum allowable height is 6.0 m (20 ft) measured from the lowest finished grade to the peak of the roof; only single storey accessory buildings will be allowed; attached carports with greater than 60% of the total perimeter enclosed by walls, doors or windows are viewed the same as attached garages and are not considered an accessory building. 7. Undersized Lots: Cottage subdivision lots will only require a 3m (10ft) front setback (reduced from 6m (20ft) when: the lot is less than 27.4m (90ft) in length; and Irregular shaped lots are less than 1828m2 (6000 ft2) and also less than 27.4m (90ft) in length. 8. Green Space: A 25% minimum of undeveloped (natural) green space or soft landscaping (including setbacks) must be provided on all leased lots. 9. Lot Adjustment: Adjustment of the lot boundary is limited to permanent structures only; and where trespass/encroachment issues between neighbours exist (limited to cottages and garages only); and in the event the neighbour will not agree to a lot adjustment, the offending structure may remain in trespass/encroachment with a total lot development freeze until such

3 Page 3 time the neighbouring cottager requires that land for an approved permanent structure. 10. Development Freeze: If an encroachment issue is identified a development freeze will apply to the offending structure. A development freeze does not allow for any further development of the offending structure until the offending structure(s) has been brought into compliance. Parks will provide a documented reason for the freeze. A development freeze will be placed on structures constructed prior to April 1, 2008 which are identified to be encroaching in the property setback areas and the development freeze will be removed once the nonconforming structures are brought into compliance; and after April 1, 2008 (when RPR s were required) any encroachments identified in the setback areas will be required to be moved/removed. 11. Decks: Uncovered decks or platforms lower than 600 mm (2 ft) from the ground to the walking surface do not require any setbacks but may not trespass; deck walking surfaces 600 mm (2 ft) to 1.8 m (5 10 ) above ground require a minimum 0.9 m (36 ) high railing and must be outside the setback area; deck walking surfaces more than 1.8 m (5 10 ) above ground require a minimum 1.07 m (42 ) high railing and must be outside the setback area; and existing decks that are determined to be unsafe by the local park official must be brought into compliance with the current National Building Code (NBC) within a reasonable timeframe and may require removal of the existing deck. 12. Development/Building Permit - Required when: Development or construction (new, alterations, additions, structural repair, replacement, removal or demolition) of buildings or structures greater than 9.2 m2 (100 ft2); and decks higher than 600 mm (2 ft) from ground to the walking surface. 13. No Fee Development/Building Permit Required when: Required for buildings or structures less than 9.2 m2 (100 ft2); sidewalks; driveways; or decks lower than 600 mm (2 ft) from the ground to the walking surface; not applicable for development/construction larger than 9.2 m2 (100 ft2); and page one of the current building permit application will be issued and approved at the park without a fee associated. 14. Permitted Yard Encroachments 1) Windows, Sill, Eave, Etc. A window or bay window may project a maximum of 300 mm (1 ft) into any required setback; and A sill, belt course, cornice, eaves, gutter, chimney chase and similar non-structural architectural features may project a maximum of 600 mm (2 ft) into any required setback; and the total setback space covered by all the projections mentioned above with the exception of eaves and gutters, taken on a horizontal plane through the widest projection, shall not exceed 2.43 m (8 ft).

4 Page 4 a) All projections on the building are located on one side only; and b) The total of a horizontal plane through the widest projections does not exceed 2.43 m (8 ft). 2) Balconies, Decks, and Uncovered Platforms A balcony, deck or uncovered platform that is more than 600 mm (2 ft) from the ground to the walking surface may project 1.8 m (5 10 ) into any required front yard; and an uncovered platform or deck that is not more than 600 mm (2 ft) from the ground to the walking surface does not require setbacks but cannot trespass. 3) Steps & Wheelchair Ramps Steps more than 600 mm (2 ft) from finished ground may not encroach into the setback areas. Wheelchair ramps may be allowed to encroach into the setback areas to a maximum 1200mm (4 ft) wide. 4) Air Conditioner /Heat Exchanger stand-alone type air conditioner or heat exchanger shall not be located: a) closer to the front lot line than the front wall of the principal building, including any attached garage; and b) closer than 3 m (10 ft) to a door or window of a dwelling on an adjoining lot. exterior air conditioning units only allowed at the back and sides of the principal building. 15. Water and Sewage System Installations: All septic tanks and holding tanks must be CSA approved. A septic tank or a holding tank servicing a building which contains a pressurized, or gravity fed water system, must have a minimum 4500 litre (1000 gallon) capacity; septic tanks must have structural integrity and be watertight; pursuant to Regional Health Authorities the closest side of a septic tank, holding tank or water tank must be located at least: a) 7.6 m (25 ft) from a well; b) 3.0 m (10 ft) from any lot boundary; lessee is responsible to obtain necessary permits/approvals from the Regional Health Authority for the proposed installation ; and must submit a Water & Sewage System Installations Permit Application (pursuant to Park Regulations) obtained from the provincial park office. 16. Propane Storage Tank Placement To protect the health and safety of everyone near a propane tank and in surrounding areas, distance rules are applicable to propane tanks and their connections in relation to what surrounds them, whether it's a house or another propane tank. Please refer to the following website which outlines provincial requirements: A tank used in a consumer application shall be located with respect to a property line, building opening, or an adjacent tank in accordance with CAN/CSA B149.2 Table 7.4. (attached)

5 Page 5 DEFINITIONS: Accessory Building a non-habitable (no provisions for eating, sleeping or plumbing) structure for the storage of equipment and supplies used in maintaining the principal building and its grounds or parking (garage). Altering or Altered - a change from one major occupancy class or division to another, or a structural change such as an addition to the area or height, or the removal of part of a building, or any change to the structure. Development any improvements or lot alterations that require a development/building permit Development Freeze - no further development will be approved for until the offending structure(s) has been brought into compliance. Structural will apply to all structures that do not comply with current development directives. Total Lot will apply in instances where a permanent structure is in trespass. Development/Building Permit a document required to proceed with any lot improvements to the leased property with an authorization in writing by the authority having jurisdiction to perform work regulated by these requirements. Dwelling one or more habitable rooms used or intended to be used as a domicile by one or more persons and usually containing cooking, eating, living, sleeping and sanitary facilities. Encroachment any building or structure extending into the setback area of the lot boundaries. Floor Area the space on any storey of a building between exterior walls and required firewalls, including the space occupied by interior walls and partitions, but not including exits, vertical service spaces, and their enclosing assemblies. Footprint Area - the entire area of ground covered by permitted structures. Front of lot the street side of any surveyed lot is the front unless written documentation received by a park official indicates otherwise. Park official will designate the front of the lot in the event there is not a street side. Grade the lowest of the average levels of finished ground adjoining each exterior wall of a building, except that localized depressions such as for vehicle or pedestrian entrances need not be considered in the determination of average levels of finished ground. Grandfather any building or structure is allowed to remain in its present state and location unless it is a risk to public safety until it is replaced, altered and/or a building permit is required. Guest House/Bunk House a structure detached from the dwelling which contains sleeping quarters, but does not contain cooking or plumbing facilities. Holding Tank a sealed tank designed to resist leaks that provide containment of solid sewage waste but provides no separation of solids; it is the only alternative for areas where septic tanks cannot be used. No Fee Development/Building Permit a document with NO fee associated authorizing the lessee to proceed with lot improvements to the leased property. This permit may be authorized by the local provincial park official.

6 Page 6 Pre-Approved written authorized received by the designated licensed building official prior to relocation of a RTM or Used Home into a provincial park cottage subdivision. Real Property Report (RPR) - a legal document prepared by a registered Saskatchewan Land Surveyor that clearly illustrates above ground structures in relation to property boundaries. The document consists of a plan showing the physical improvements with dimensions to boundaries and a written report outlining the details of the property. Residential Occupancy the occupancy or use of a building or part thereof by persons for whom sleeping accommodation is provided as described in the National Building Code (NBC). Septic Tank underground sewage and waste-water system that disposes of filter waste, separating the solids from the liquids. It allows solid waste to break down into waste water so it leaves the system as a liquid. Setback the reserved area on the edge of your property within which building structures are prohibited. Soft Landscaping vegetative materials used to improve a landscape (lawns, embankments, flowers, shrubs); green space does not include aggregate. Surveyed Lot a legal plan of survey prepared by a Saskatchewan Land Surveyor (SLS) Trespass - any building or portion thereof is extending on, over, across, the property boundaries onto streets, lanes, green spaces or neighboring property.

7

8 June 2012 Guest House/Sleep Sheds Requirements for new and existing: 1. One room, single storey structures permitted. 2. Will count as 1 of the maximum 3 accessory buildings permitted. 3. Maximum size of 320 ft 2 to be included in the maximum 50% aggregated total lot coverage. 4. Maximum height of 6M (20 ft) from the lowest grade to the peak of the roof. 5. Must be located at least 2.4M (8 ft) from any other structures and cannot be located within the setback areas. 6. Provide clear access to the building for emergency/fire officials. 7. A building permit application is required for all guest houses, regardless of size (walk through inspections are required to be conducted by the Park Officials and/or Building Official). 8. Foundation in accordance with NBC Articles , and a. Appropriately anchored (ground anchors); and b. Can be on wood mudsills, slab on grade or standard foundations (as per 9.15). 9. Drainage in accordance with applicable articles in NBC Subsection a. Sloped gravel base and poly protection. 10. Framing in accordance with acceptable practices and NBC Subsection a. Beam, joist and lintels sized to Code; and b. Rafters and roof framing installed as per Code. 11. Windows and doors in accordance with NBC Articles and a. Windows sealed from water and precipitation; and b. Windows and doors to installed as per Code. 12. Electrical service in accordance with applicable articles in NBC Section 9.34 and the Canadian Electrical Code and The Electrical Inspection Act, a. Electrical permit required; and b. Electrical power is required with proper trenching and breakers 13. Smoke alarms in accordance with NBC Subsection a. permanent connections to an electrical circuit; and b. no disconnect switch between the overcurrent device and the alarm 14. Interior finish in accordance with applicable articles in NBC Section a. If finished must meet required flame spread ratings and be nonflammable; and b. Installation as per Code of all interior finishes 15. Exterior finish in accordance with NBC Subsections 9.27 or a. Finished to protect building from precipitation; and b. Installation of Cladding as per appropriate Code 16. Roofing in accordance with NBC Subsection a. Finished to protect from precipitation (e.g. Shingles, metal or other as identified in the Code); and b. Installation as per appropriate Code. 17. Fire Protection and egress in accordance with NBC Subsection 9.10 and 9.9 a. Sleeping rooms to have egress compliant window or exterior door.

9

PART R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT

PART R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT PART 3.2 - R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT Uses 1 The following uses are permitted: (a) single family dwellings; (b) two family dwellings; (c) multiple dwellings; (d) churches; (e) public

More information

This brochure outlines zoning information for single-family and two-family dwellings in the R1 to R5 and R9 to R10 Districts.

This brochure outlines zoning information for single-family and two-family dwellings in the R1 to R5 and R9 to R10 Districts. Accessory Buildings This brochure outlines zoning information for single-family and two-family dwellings in the R1 to R5 and R9 to R10 Districts. It is intended for convenience only and cannot be used

More information

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax:

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax: Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL 60148 Tel: 630-620-5750 Fax: 630-629-2374 Accessory Structures: Decks, Terraces, Gazebos, Porches,

More information

DETACHED GARAGES. Construction requirements for detached garages and storage sheds for residential dwellings. Portage la Prairie Planning District

DETACHED GARAGES. Construction requirements for detached garages and storage sheds for residential dwellings. Portage la Prairie Planning District Every effort has been made to ensure the accuracy of the information contained in this brochure. However, in case of a discrepancy between this brochure and the respective By-laws, the applicable By-law

More information

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER THE CORPORATION OF THE MUNICIPALITY OF SOUTH HURON 322 Main Street South, P.O. Box 759, Exeter, Ontario N0M 1S6 PHONE: (519) 235-0310 FAX: (519) 235-3304 TOLL FREE: 1-877-204-0747 WEBSITE: www.southhuron.ca

More information

SECTION GENERAL PROVISIONS PURPOSE.

SECTION GENERAL PROVISIONS PURPOSE. Section 1104 - Page 1 SECTION 1104.00 GENERAL PROVISIONS. 1104.01 PURPOSE. The purpose of this Section is to establish general development performance standards. These standards are intended and designed

More information

Proposed Amendments to Residential Zoning Draft Revised 06/27/2018

Proposed Amendments to Residential Zoning Draft Revised 06/27/2018 Proposed Amendments to Residential Zoning Draft Revised 06/27/2018 [Add the following new section to R-1A and R-1B (as 19.06.030 and 19.08.0925 respectively)] [19.06.030 / 19.08.025] Neighborhood Design

More information

Detached garages/ Sheds/ Gazebo s

Detached garages/ Sheds/ Gazebo s Detached garages/ Sheds/ Gazebo s Include in package: 1. Development Permit Application-Fee $100.00 & $500.00 Security Deposit Indicate the location- Civic address and Beach, or Legal Land Description

More information

SINGLE FAMILY REGULATIONS UNDERSTORY AREAS ORDINANCE NO.

SINGLE FAMILY REGULATIONS UNDERSTORY AREAS ORDINANCE NO. SINGLE FAMILY REGULATIONS UNDERSTORY AREAS ORDINANCE NO. AN ORDINANCE OF THE MAYOR AND CITY COMMISSION OF THE CITY OF MIAMI BEACH, FLORIDA, AMENDING THE LAND DEVELOPMENT REGULATIONS OF THE CODE OF THE

More information

HOW TO OBTAIN A BUILDING PERMIT

HOW TO OBTAIN A BUILDING PERMIT HOW TO OBTAIN A BUILDING PERMIT A GUIDE TO THE HOMEOWNER Copies of this Guide can be obtained from the Building Department upon request THE CORPORATION OF THE TOWNSHIP OF GEORGIAN BAY BUILDING DEPARTMENT

More information

Residential Zoning Rules

Residential Zoning Rules Residential Zoning Rules Applications for building permits must contain plans and information that show that the proposal meets the requirements of the International and Washington State building codes,

More information

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS)

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS) 1420 Miner Street Des Plaines, IL 60016 P: 847.391.5380 desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS) Five sets of stamped plans and specifications (six sets if food establishment),

More information

Temporary Emergency Housing Units October 17, 2013

Temporary Emergency Housing Units October 17, 2013 www.larimer.org Community Development Division 200 W. Oak Street - 3 rd Floor P.O. Box 1190 Fort Collins, CO 80521 970-498-7683 Temporary Emergency Housing Units October 17, 2013 Disaster Rebuild Program

More information

Residential Building Permits

Residential Building Permits JWS INSPECTION SERVICE 3407-43B Avenue Lloydminster, Saskatchewan S9V-2G1Ph:780-808-5704 Email: jsydoruk@sasktel.net Residential Building Permits A residential building is a one or two unit dwelling, along

More information

General Requirements for Mobile Homes

General Requirements for Mobile Homes Mobile homes shall conform in all respects to the CAN/CSA-Z240 MH Series of Standards and shall be complete structurally with the entire plumbing, electrical, and heating services installed. Prior to moving

More information

FIRST READING March 26,

FIRST READING March 26, FIRST READING March 26, 2019 2019-05 ORDINANCE AMENDING CHAPTER 135 ENTITLED LAND DEVELOPMENT FOR VARIOUS SECTIONS REGARDING THE MASS AND SCALE OF HOMES NOW THEREFORE, BE IT ORDAINED by the Board of Commissioners

More information

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE I MUNICIPAL SITE PLAN & LOT GRADING REQUIREMENTS (SUBDIVISION LOTS) Revised: November 18, 2014 1. INTRODUCTION This guide is intended to

More information

Proposed Amendments to Residential Zoning Final Draft Revised 08/29/2018

Proposed Amendments to Residential Zoning Final Draft Revised 08/29/2018 Proposed Amendments to Residential Zoning Final Draft Revised 08/29/2018 Drafting Notes: The 8/29/18 draft reflects the following changes from the 7/25/18 draft based on City Council and/or Planning Commission

More information

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS

THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE PART I MUNICIPAL BUILDING REQUIREMENTS THE CORPORATION OF THE TOWNSHIP OF HAMILTON HOME BUILDER S GUIDE I MUNICIPAL SITE PLAN & LOT GRADING REQUIREMENTS (SUBDIVISION LOTS) Revised: July 27, 2017 1. INTRODUCTION This guide is intended to advise

More information

Red Fox Run Property Owner s Association, Inc. P.O. Box 194 Tryon, NC 28782

Red Fox Run Property Owner s Association, Inc. P.O. Box 194 Tryon, NC 28782 Red Fox Run Property Owner s Association, Inc. P.O. Box 194 Tryon, NC 28782 Members of the Red Fox Run Property Owner s Association, Inc. Attached are the guidelines of the Architectural Review Committee

More information

SECTION 10 - HIGHWAY COMMERCIAL ZONE (C2) REGULATIONS

SECTION 10 - HIGHWAY COMMERCIAL ZONE (C2) REGULATIONS SECTION 10 - HIGHWAY COMMERCIAL ZONE (C2) REGULATIONS 10.1 GENERAL USE REGULATIONS 10.1.1 PERMITTED USES No land, building, or structures shall be used or erected in the Highway Commercial Zone (C2) except

More information

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA 94596 (925) 943-5834 phone (925) 256-3500 fax Issued August 3, 2011 Information Bulletin No. IB-002 Submittal Requirements

More information

RT-10 and RT-10N Districts Schedule

RT-10 and RT-10N Districts Schedule Districts Schedule 1 Intent The intent of this Schedule is to encourage development of multiple small houses and duplexes on large lots and assembled sites, while continuing to permit lower intensity development

More information

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE - 268-5161 Residential Accessory Structures This information has been compiled for the benefit of any person

More information

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following:

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following: New buildings or renovations to existing buildings for which an application for a permit was made to the Department or a municipality before April 9, 2004. New buildings or renovations to existing buildings

More information

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507) City of North Mankato 1001 Belgrade Avenue North Mankato, MN 56003 (507) 625-4141 BUILDING PERMIT GUIDELINES Building Permits are required for all improvements with a value** of $300.00 or more. Sheds,

More information

VILLAGE OF BETHUNE BYLAW NO. 3/2010

VILLAGE OF BETHUNE BYLAW NO. 3/2010 VILLAGE OF BETHUNE BYLAW NO. 3/2010 A BYLAW OF THE VILLAGE OF BETHUNE RESPECTING BUILDINGS The Council of the Village of Bethune, in the Province of Saskatchewan enacts as follows: 1.0 Title 1.1 Short

More information

HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE

HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE HALIFAX REGIONAL MUNICIPALITY BY-LAW NUMBER B-201 RESPECTING THE BUILDING CODE BE IT ENACTED by the Council of the Halifax Regional Municipality under the authority of the Building Code Act as follows:

More information

HOW TO OBTAIN A BUILDING PERMIT

HOW TO OBTAIN A BUILDING PERMIT HOW TO OBTAIN A BUILDING PERMIT A GUIDE TO THE HOMEOWNER Copies of the Guide can be obtained from the Building Department of Highlands East or on our web site: www.highlandseast.ca Municipality of Highlands

More information

RS-5 District Schedule

RS-5 District Schedule District Schedule 1 Intent The intent of this Schedule is generally to maintain the existing single-family residential character of the District by encouraging new development that is compatible with the

More information

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507)

City of North Mankato 1001 Belgrade Avenue North Mankato, MN (507) City of North Mankato 1001 Belgrade Avenue North Mankato, MN 56003 (507) 625-4141 BUILDING PERMIT GUIDELINES Building Permits are required for all improvements with a value** of $300.00 or more. Sheds,

More information

District of Ucluelet Building Permit Guide

District of Ucluelet Building Permit Guide District of Ucluelet Building Permit Guide The purpose of this guide is to advise on the applicable regulations within the District of Ucluelet regarding construction, repairs, alterations or additions

More information

Accessory Dwelling Unit Permit Submittal Requirement Checklist (Corte Madera Municipal Code Section 18.31)

Accessory Dwelling Unit Permit Submittal Requirement Checklist (Corte Madera Municipal Code Section 18.31) PLANNING DEPARTMENT 300 TAMALPAIS DRIVE CORTE MADERA, CA 94925 Accessory Dwelling Unit Permit Submittal Requirement Checklist (Corte Madera Municipal Code Section 18.31) Address of Project Site Definition:

More information

A guide to: ACCESSORY BUILDINGS. Brought to you by: City of Port Colborne - Building Division

A guide to: ACCESSORY BUILDINGS. Brought to you by: City of Port Colborne - Building Division A guide to: ACCESSORY BUILDINGS Brought to you by: City of Port Colborne - Building Division -----------------------------------------Disclaimer---------------------------------------- This information

More information

4.0 Development Regulations

4.0 Development Regulations 4.0 Development Regulations DEVELOP 4.1 Building Shadow Analysis 4.1.1 Shadow analysis regulations shall apply to every building within a commercial or RH Residential zone as outlined on Diagram 4.1: Application

More information

Item Permitted/Required Code reference Proposal Complies? Lot Area: see also LU- P-5

Item Permitted/Required Code reference Proposal Complies? Lot Area: see also LU- P-5 Community Development Department City of Pismo Beach 760 Mattie Road Pismo Beach, CA 93449 Telephone: (805) 773-4658 / Fax: (805) 773-4684 Address: APN: Area P: Outside Coastal Zone Development Standards

More information

TOWN OF ROTTERDAM BUILDING DEPARTMENT RESIDENTIAL ACCESSORY BUILDINGS AND STRUCTURE PERMIT APPLICATION Ext 395

TOWN OF ROTTERDAM BUILDING DEPARTMENT RESIDENTIAL ACCESSORY BUILDINGS AND STRUCTURE PERMIT APPLICATION Ext 395 TOWN OF ROTTERDAM BUILDING DEPARTMENT RESIDENTIAL ACCESSORY BUILDINGS AND STRUCTURE PERMIT APPLICATION 518-355-7575 Ext 395 Needed to Obtain a Residential Accessory Structure Building Permit: 1. Building

More information

COUNTY OF SAN BERNARDINO 2007 DEVELOPMENT CODE

COUNTY OF SAN BERNARDINO 2007 DEVELOPMENT CODE COUNTY OF SAN BERNARDINO 2007 DEVELOPMENT CODE Prepared for: County of San Bernardino Land Use Services Division 385 North Arrowhead Avenue, 1st Floor San Bernardino, CA 92415-0182 Adopted March 13,2007

More information

CHAPTER MANUFACTURED HOME PARKS

CHAPTER MANUFACTURED HOME PARKS CITY OF MOSES LAKE MUNICIPAL CODE CHAPTER 18.65 MANUFACTURED HOME PARKS Sections: 18.65.010 Intent 18.65.020 Binding Site Plan 18.65.030 Permitted Uses and General Requirements 18.65.040 Manufactured Home

More information

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION Town of Hague Building Inspector: Dale Wagner Home #: 306-225-2265 Cell #: 306-241-4741 Fill all part of the permit application including the date and signature.

More information

Building Height and Cellars, Basements and Crawl Spaces

Building Height and Cellars, Basements and Crawl Spaces Planning and Building Department ZONING INFORMATION Building Height and Cellars, Basements and Crawl Spaces Updated: 2017 August 25 This brochure outlines zoning information for single-family and two-family

More information

6.0. ARCHITECTURAL AND CONSTRUCTION REQUIREMENTS General

6.0. ARCHITECTURAL AND CONSTRUCTION REQUIREMENTS General 6.0. ARCHITECTURAL AND CONSTRUCTION REQUIREMENTS 6.1. General Article V of the Covenants, Conditions and Restrictions (CC&Rs) mandates that all construction within LACC shall conform to Plumas County codes

More information

Development Application Package

Development Application Package Development Application Package Please review the Land Use Bylaw (LUB) 99/13 for the regulations pertaining to your development. Common Developments - For your convenience, the following developments have

More information

TOWNSHIP OF DRUMMOND/NORTH ELMSLEY. Deck/Porch Guide & Permit

TOWNSHIP OF DRUMMOND/NORTH ELMSLEY. Deck/Porch Guide & Permit TOWNSHIP OF DRUMMOND/NORTH ELMSLEY Deck/Porch Guide & Permit New Dwelling Living Space Additions to Dwelling Living Space Summary of Building Permit Rates (calculations are based on outside dimensions)

More information

THE CORPORATION OF THE UNITED TOWNSHIPS OF DYSART, DUDLEY, HARCOURT, GUILFORD, HARBURN, BRUTON, HAVELOCK, EYRE AND CLYDE BY-LAW NO.

THE CORPORATION OF THE UNITED TOWNSHIPS OF DYSART, DUDLEY, HARCOURT, GUILFORD, HARBURN, BRUTON, HAVELOCK, EYRE AND CLYDE BY-LAW NO. THE CORPORATION OF THE UNITED TOWNSHIPS OF DYSART, DUDLEY, HARCOURT, GUILFORD, HARBURN, BRUTON, HAVELOCK, EYRE AND CLYDE BY-LAW NO. 2014-30 BEING A BY-LAW RESPECTING CONSTRUCTION, DEMOLITION AND CHANGE

More information

Permit Procedures For New Construction, Additions, and Alterations

Permit Procedures For New Construction, Additions, and Alterations City of Lexington 329 W. Main Street Lexington, IL. 61753 For questions, call: 309-825-8215 Application For Plan Review And Permit Procedures For New Construction, Additions, and Alterations Submit Plans:

More information

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS) 1102 4 th Street Telephone: 306-634-1819 Estevan, Saskatchewan, Canada Fax: 306-636-2199 S4A 0W7 INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

More information

Section 1 Non-Conforming Structures and Uses Allowed to Continue. 12

Section 1 Non-Conforming Structures and Uses Allowed to Continue. 12 CHAPTER 3 NONCONFORMITIES Section 1 Non-Conforming Structures and Uses Allowed to Continue. 12 Section 2 Discontinuance 12 Section 3 Change of Use... 12 Section 4 Residential Alterations 12 Section 5 Restoration..

More information

One and Two Family Additions

One and Two Family Additions One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri

More information

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit: TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION 355-7575 Ext. 395 Needed to Obtain Permit: 1. Building Permit Application, and/or residential plumbing permit application, as applicable, to be

More information

Township of Georgian Bluffs. Building Permit Information

Township of Georgian Bluffs. Building Permit Information Township of Georgian Bluffs Building Permit Information Please read carefully as it may affect approval of your Building Permit Building and Planning Department Township of Georgian Bluffs 177964 Grey

More information

CITY OF MERCER ISLAND

CITY OF MERCER ISLAND CITY OF MERCER ISLAND DEVELOPMENT SERVICES GROUP 9611 SE 36TH STREET MERCER ISLAND, WA 98040 PHONE: 206.275.7605 www.mercergov.org Inspection Requests: Online: www.mybuildingpermits.com VM: 206.275.7730

More information

BUILDING PERMIT INFORMATION PLEASE READ CAREFULLY AS IT MAY AFFECT APPROVAL OF YOUR BUILDING PERMIT

BUILDING PERMIT INFORMATION PLEASE READ CAREFULLY AS IT MAY AFFECT APPROVAL OF YOUR BUILDING PERMIT TOWNSHIP OF GEORGIAN BLUFFS BUILDING PERMIT INFORMATION PLEASE READ CAREFULLY AS IT MAY AFFECT APPROVAL OF YOUR BUILDING PERMIT Building and Planning Department Township of Georgian Bluffs 177964 Grey

More information

5/15/2013. Approved Course Title 2010 Existing Building Code Chapters Florida Building Code, Existing Building. Chapters

5/15/2013. Approved Course Title 2010 Existing Building Code Chapters Florida Building Code, Existing Building. Chapters 2010 Florida Building Code, Existing Building A Code for Existing Buildings Approved Course Title 2010 Existing Building Code Chapters 10-14 Chapters 10-14 Module Objectives Chapter 1 Administration Chapter

More information

SITE DEVELOPMENT INFORMATION Worksheet for single family residential development

SITE DEVELOPMENT INFORMATION Worksheet for single family residential development CITY OF MERCER ISLAND DEVELOPMENT SERVICES GROUP 9611 SE 36TH STREET MERCER ISLAND, WA 98040 PHONE: 206.275.7605 www.mercergov.org Inspection Requests: Online: www.mybuildingpermits.com VM: 206.275.7730

More information

SAFEGUARDS DURING CONSTRUCTION

SAFEGUARDS DURING CONSTRUCTION CHAPTER 14 SAFEGUARDS DURING CONSTRUCTION SECTION 1401 GENERAL [B] 1401.1 Scope. The provisions of this chapter shall govern safety during construction that is under the jurisdiction of this code and the

More information

Architectural and Landscape Guidelines

Architectural and Landscape Guidelines Architectural and Landscape Guidelines Introduction The document outlines the opportunities and constraints associated with the Wolf Creek Village development and provides a set of subdivision guidelines

More information

RS-7 District Schedule

RS-7 District Schedule District Schedule 1 Intent The intent of this Schedule is: to maintain the single-family residential character of the District; on typical smaller lots, to conditionally permit two-family dwellings, multiple

More information

ZONING CLEARANCE PLAN REVIEW CHECKLIST. Based on the Revised Town of Carefree Zoning Ordinance

ZONING CLEARANCE PLAN REVIEW CHECKLIST. Based on the Revised Town of Carefree Zoning Ordinance ZONING CLEARANCE PLAN REVIEW CHECKLIST Based on the Revised Town of Carefree Zoning Ordinance Date: Applicant: Permit Number: Reviewer: Address: Lot & Subdivision: Zoning District: New SRF: Addn/Remodel:

More information

RS-5 District Schedule

RS-5 District Schedule District Schedule 1 Intent The intent of this Schedule is generally to maintain the existing single-family residential character of the District by encouraging new development that is compatible with the

More information

Wildwood Home Owners Association Architectural Review Board Guidelines

Wildwood Home Owners Association Architectural Review Board Guidelines Wildwood Home Owners Association Architectural Review Board Guidelines A. STATEMENT OF OBJECTIVES : 1. It is the intention of Wildwood Home Owners Association, through this review board, to provide the

More information

The Corporation of the City of Kenora. By-law Number A By-law to Amend the Comprehensive Zoning By-Law Number , as amended

The Corporation of the City of Kenora. By-law Number A By-law to Amend the Comprehensive Zoning By-Law Number , as amended The Corporation of the City of Kenora By-law Number 15-2012 A By-law to Amend the Comprehensive Zoning By-Law Number 160-2010, as amended Whereas the Council of the Corporation of the City of Kenora passed

More information

CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING

CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING See Setback/Coverage Worksheet & Criteria: Pages 1-4 & Accessory Structure Guide Step 1 Step 2 Step 3 Step 4 Step 5 Step 6

More information

BUILDING CONSTRUCTION

BUILDING CONSTRUCTION BUILDING CONSTRUCTION Chapter 66 From the CODE of the TOWN OF WINDHAM COUNTY OF CUMBERLAND STATE OF MAINE 66-1. Purpose. The Town of Windham enforces the Maine Uniform Building and Energy Code ( M.U.B.E.C.

More information

CITY OF KIRKWOOD SINGLE FAMILY SITE PLAN WORKSHEET

CITY OF KIRKWOOD SINGLE FAMILY SITE PLAN WORKSHEET S. F. Review No. ZONING DISTRICT PROPERTY ADDRESS CITY OF KIRKWOOD SINGLE FAMILY SITE PLAN WORKSHEET A Missouri Minimum Standards Boundary Survey is required to be filed in support of this worksheet, showing

More information

HOUSE ADDITIONS A guide to the plans required when applying for a Building Permit

HOUSE ADDITIONS A guide to the plans required when applying for a Building Permit PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT HOUSE ADDITIONS A guide to the plans required when applying for a Building Permit November 2017 contents Introduction... 3 Site Plan... 4 Floor Plan... 6 Foundation

More information

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations Section 16.20.020 - Neighborhood Suburban Single-Family Districts ( NS ) Sections: Typical Block in a Neighborhood Suburban District 16.20.020.1 History and Composition of Suburban Neighborhoods 16.20.020.2

More information

Section 7 ACCESSORY BUILDINGS AND STRUCTURES. 7.1 USES PERMITTED AS ACCESSORY BUILDINGS AND STRUCTURES: Amended, 17-33, 11-22, 01-34

Section 7 ACCESSORY BUILDINGS AND STRUCTURES. 7.1 USES PERMITTED AS ACCESSORY BUILDINGS AND STRUCTURES: Amended, 17-33, 11-22, 01-34 Section 7 ACCESSORY BUILDINGS AND STRUCTURES 7.1 Uses Permitted as Accessory Buildings and Structures 7.2 Location of Accessory Buildings and Structures 7.3 Construction of Accessory Buildings and Structures

More information

Residential Miscellaneous Permits

Residential Miscellaneous Permits Residential Miscellaneous Permits Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org

More information

Uniform Construction Code

Uniform Construction Code Uniform Construction Code When the UCC Requires Permits and Inspections (A Zoning Certificate may be required even though the project does not require a UCC Building Permit.) As a general rule, the UCC

More information

meters (16 Inches) Transportation (T)

meters (16 Inches) Transportation (T) OFFICE USE ONLY Application # Town of Steady Brook BUILDING AND DEVELOPMENT APPLICATION {All Applications must include copy of Legal Survey, showing all measurements And distances required} {Processing

More information

RS-1 District Schedule

RS-1 District Schedule District Schedule 1 Intent The intent of this Schedule is generally to maintain the single-family residential character of the District, but also to permit conditionally one-family dwellings with secondary

More information

The following are exceptions to the use regulations of the district regulations of this ordinance.

The following are exceptions to the use regulations of the district regulations of this ordinance. Article.01 Purpose The purpose of this article is to establish regulations and conditions that are generally applicable to all districts of this Ordinance unless otherwise indicated. It is to provide uniform

More information

Section 7 ACCESSORY BUILDINGS, STRUCTURES AND USES

Section 7 ACCESSORY BUILDINGS, STRUCTURES AND USES Section 7 ACCESSORY BUILDINGS, STRUCTURES AND USES 7.1 Uses Permitted as Accessory Buildings, Structures and Uses 7.2 Location of Accessory Buildings, Structures and Uses 7.3 Construction of Accessory

More information

City of Rohnert Park When Permits are Required

City of Rohnert Park When Permits are Required Permits are required as provided below based on the applicable code governing the trades involved in a building project. In some instances more than one trade may be involved in a project so be sure to

More information

District of Barriere A GUIDE TO BUILDING PERMITS

District of Barriere A GUIDE TO BUILDING PERMITS District of Barriere A GUIDE TO BUILDING PERMITS THIS BROCHURE EXPLAINS: When a Building Permit is required Building Application Procedure District of Barriere Review of the Permit Application Additional

More information

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form. The Homeowner s Building Application Checklist for Constructing a Residential Accessory Building This checklist provides homeowners a summary of the Building Permit submission requirements for constructing

More information

PART 6 GENERAL REGULATIONS

PART 6 GENERAL REGULATIONS PART 6 GENERAL REGULATIONS The General Regulations set forth in Part 6 shall apply to Development in all Districts, and may be amended in the same manner as any other Part or Section of this Bylaw. SECTION

More information

Fees and Permit requirements are regulated by the Township s Building By-law

Fees and Permit requirements are regulated by the Township s Building By-law Frequently Asked Questions This is a guide only and is intended to help you, the homeowner/builder, to better understand the steps to follow in obtaining a Building Permit; it is not a substitute for the

More information

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT 1 East Franklin Street Phone: 301-790-4163 Third Floor Hagerstown, MD 21740 Fax: 301-791-2650 BUILDING PERMIT APPLICATION FOR RESIDENTIAL ACCESSORY

More information

ARTICLE III. TECHNICAL CODES AND OTHER CONSTRUCTION STANDARDS* Sec Adoption of the Florida Building Code and Countywide Amendments.

ARTICLE III. TECHNICAL CODES AND OTHER CONSTRUCTION STANDARDS* Sec Adoption of the Florida Building Code and Countywide Amendments. Page 1 of 6 ARTICLE III. TECHNICAL CODES AND OTHER CONSTRUCTION STANDARDS* *Cross references: Coastal construction code, 67-16 et seq.; building standards, 67-171 et seq. State law references: Construction

More information

PERFORMANCE STANDARDS

PERFORMANCE STANDARDS Sections: 9-101 Purpose 9-102 Performance Standards - District "AG" 9-103 Performance Standards - Districts R-1, "R-2", "R-3" and "V-1" 9-104 Performance Standards - Conditional Uses 9-101 Purpose: The

More information

General Building Information

General Building Information Software Module s Description Page 1 General Building Information BUILDING AREA AND HEIGHT - This module designed to determine the height and area of buildings on the basis of occupancy group classification

More information

RESIDENTIAL GARAGE AND DRIVEWAY

RESIDENTIAL GARAGE AND DRIVEWAY RESIDENTIAL GARAGE AND DRIVEWAY GENERAL REQUIREMENTS: PERMIT: For new garages or garage additions the fee is $20.00 per hundred square feet or portion thereof ($50 minimum). Demolition permits are $65.00

More information

RS-1 District Schedule

RS-1 District Schedule District Schedule 1 Intent The intent of this Schedule is generally to maintain the single-family residential character of the District, but also to permit conditionally one-family dwellings with secondary

More information

5/9/ Florida Building Code, Existing Building. Chapters Approved Course Title 2010 Existing Building Code Chapters

5/9/ Florida Building Code, Existing Building. Chapters Approved Course Title 2010 Existing Building Code Chapters 2010 Florida Building Code, Existing Building A Code for Existing Buildings This slide is being narrated. If you do not hear a voice, check your speakers or return to the Main Menu and click on System

More information

Application for Commercial Plan Review and Building Permit. Address:

Application for Commercial Plan Review and Building Permit. Address: City of Warrenton 200 West Booneslick Warrenton, MO 63383 : 636-456-3535 Fax: 636-456-1336 www. war r ent o n- mo.org Application for Commercial Plan Review and Building Permit PERMIT# Purpose: Commercial

More information

ARTICLE 4 SUPPLEMENTARY PROVISIONS

ARTICLE 4 SUPPLEMENTARY PROVISIONS ARTICLE 4 SUPPLEMENTARY PROVISIONS Section 4-10 1. Permitted Uses and Conditional Uses Permitted uses and uses permitted by special review may be located in the same building Section 4-102. District Boundaries

More information

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE Chapter 23.12 UNIFORM CODES FOR CONSTRUCTION BUILDING CODE 23.12.010 Adoption of the 2010 California Building Code. Part 2. Title 24 of the California Code of Regulations. There is adopted and incorporated

More information

PLANNING DEPARTMENT. Introduction

PLANNING DEPARTMENT. Introduction COUNTY OF SANTA CRUZ PLANNING DEPARTMENT 701 OCEAN STREET - 4 TH FLOOR, SANTA CRUZ, CA 95060 (831) 454-2580 FAX: (831) 454-2131 TDD: (831) 454-2123 KATHLEEN MOLLOY PREVISICH, PLANNING DIRECTOR EVALUATING

More information

Residential Design Standards Draft 9 August 2013

Residential Design Standards Draft 9 August 2013 RESIDENTIAL DESIGN STANDARDS ORDINANCE DRAFT 9 AUGUST 2013 17.25 Residential Design Standards 17.25.010 Purpose The purpose of this chapter is to establish minimum design standards for new residential

More information

ATTACHED/DETACHED GARAGE BUILDING PERMIT APPLICATION

ATTACHED/DETACHED GARAGE BUILDING PERMIT APPLICATION Community Development 1050 W Romeo Rd Romeoville, IL 60446-1329 (815) 886-7200 Fax #: (815) 886-2724 Email: buildinginspections@romeoville.org ATTACHED/DETACHED GARAGE BUILDING PERMIT APPLICATION Property

More information

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code. ORDINANCE NO. 7222 AN ORDINANCE AMENDING CHAPTER 8 OF THE CODE OF ORDINANCES, REGULATING BUILDINGS WITHIN THE CORPORATE LIMITS OF THE CITY OF MANHATTAN, KANSAS; INCORPORATING BY REFERENCE THE INTERNATIONAL

More information

ONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS

ONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS ONE AND TWO FAMILY DWELLING PERMIT APPLICATION REQUIREMENTS Submit a permit application with all applicable items completed, including inserts, when you construct a new building, construct an addition,

More information

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and & &01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.

More information

Rafter J Ranch. Packet for New Residential Construction Including Additions and Alterations

Rafter J Ranch. Packet for New Residential Construction Including Additions and Alterations Rafter J Ranch Packet for New Residential Construction Including Additions and Alterations CONTENTS: 1. Application for New Residential Construction Including Additions and Alterations 2. Rules and Regulations

More information

Residential Uses in the Historic Village Core

Residential Uses in the Historic Village Core BLACK DIAMOND DESIGN GUIDLINES for Residential Uses in the Historic Village Core Adopted June 18, 2009 Introduction and Purpose These guidelines are intended to guide infill development within the Historic

More information

2010 National Building Code Adoption and Associated Process Changes

2010 National Building Code Adoption and Associated Process Changes Building Inspection City of Moncton 655 Main Street Moncton, NB E1C 1E8 Phone: (506) 856-4375 Fax: (506) 856-4348 Bulletin No. 14 From: Randy Richard Date: February 9, 2015 Subject: 2010 National Building

More information

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

RESIDENTIAL CONSTRUCTION New Dwellings and Additions How to Obtain a Building Permit For RESIDENTIAL CONSTRUCTION New Dwellings and Additions MIAMI COUNTY, KANSAS CODE SERVICES DEPARTMENT 201 South Pearl Street, Suite 201 Paola, Kansas 66071-1777 Phone:

More information